Home

USER MANUAL - Kramer Electronics

image

Contents

1. N CAUTION When installing on a 19 rack avoid hazards by taking care that 1 It is located within the recommended environmental conditions as the operating ambient temperature of a closed or multi unit rack assembly may exceed the room ambient temperature Once rack mounted enough air will still flow around the machine The machine is placed straight in the correct horizontal position You do not overload the circuit s When connecting the machine to the supply circuit overloading the circuits might have a detrimental effect on overcurrent protection and supply wiring Refer to the appropriate nameplate ratings for information For example for fuse replacement see the value printed on the product label The machine is earthed grounded in a reliable way and is connected only to an electricity socket with grounding Pay particular attention to situations where electricity is supplied indirectly when the power cord is not plugged directly into the socket in the wall for example when using an extension cable or a power strip and that you use only the power cord that is supplied with the machine To rack mount a machine 1 Attach both ear brackets to the machine To do so remove the screws from each side of the machine 3 on each side and replace those screws through the ear brackets 2 Place the ears of the machine against the rack rails and insert the proper screws not provided t
2. KRAMER SIMPLE CREATIVE TECHNOLOGY Controlling the VS 120 6 1 2 6 2 Setting the Self Address When controlling a unit through the RS 232 or RS 485 ports each unit must be identified by a unique Self Address The first unit connected to the PC is the master unit and its address must be 01 All other slave units must have unique addresses from 02 to 99 To set the self address 1 Press the SELF ADDRESS button in the SETUP section The MACHINE display flashes 2 Enter a 2 digit address using the UP DOWN buttons or the keypad 3 Press ENT to save the address Controlling via the RS 485 Port You can control up to 99 VS 120 units via the RS 485 port using e A Master Programmable Remote Control system such as the Kramer RC 3000 controller e A PC that connects via its RS 232 interface to a master VS 120 that connects up to 98 slave units through its RS 485 interface If connecting a master VS 120 to an RS 232 port in a PC first follow the steps in section 6 1 To connect an RC 3000 to a VS 120 unit or slave units to a master VS 120 1 Connect the left PIN on the RS 485 rear panel port of the master or RC 3000 to the A PIN on the RS 485 rear panel port of the VS 120 slave unit 2 Connect the center PIN on the RS 485 rear panel port of the master or RC 3000 to the PIN on the RS 485 rear panel port of the VS 120 slave unit 3 Ifshielded twisted pair cable is used the
3. covered by the warranty 1 Any product which is not distributed by Kramer or which is not purchased from an authorized Kramer dealer If you are uncertain as to whether a dealer is authorized please contact Kramer at one of the agents listed in the Web site www kramerelectronics com 2 Any product on which the serial number has been defaced modified or removed or on which the WARRANTY VOID IF TAMPERED sticker has been torn reattached removed or otherwise interfered with 3 Damage deterioration or malfunction resulting from i Accident misuse abuse neglect fire water lightning or other acts of nature ii Product modification or failure to follow instructions supplied with the product iii Repair or attempted repair by anyone not authorized by Kramer iv Any shipment of the product claims must be presented to the carrier v Removalor installation ofthe product vi Any other cause which does not relate to a product defect vii Cartons equipment enclosures cables or accessories used in conjunction with the product WHAT WE WILL PAY FORAND WHAT WE WILLNOT PAY FOR We will pay labor and material expenses for covered items We will not pay for the following 1 Removal or installations charges 2 Costs of initial technical adjustments set up including adjustment of user controls or programming These costs are the responsibility of the Kramer dealer from whom the product was purchased 3 Shipping charges HOW YOU CAN GET W
4. ignore an input error e Press the IGNORE button in the Error section The IGNORE LED illuminates and the scan continues regardless of errors Note To change the error Skip Stop and Ignore settings scanning must be stopped by pressing the STOP button in the AUTO MODE section To display the list of errored inputs 1 Press the STOP button in the AUTO MODE section to stop the scan 2 Press the LIST button in the Error section The Machine and Input displays flash the numbers of the machine and first input that has an error 3 Press the UP button to display the input errors one after another 4 You can delete each error from the list by pressing the DEL button in the Program Keys section When the list is empty the LIST LED turns off the display stops flashing and the last scanned input shows in the display Operating Multiple VS 120 Units Multiple unit configurations of the VS 120 can be created to increase the number of outputs switched or scanned Two VS 120s can be combined to create a 40 x 1 switcher scanner three units can combine into a 60 x 1 switcher scanner and so on up to 99 VS 120s The multiple unit configuration is seen as one large switcher scanner The units must be connected via their RS 485 ports see section 6 2 The first VS 120 must have Self Address 01 and following machines must have 13 Operating the VS 120 unique addresses see Figure 5 The outputs from all the machines can be tied to
5. output KRAMER SIMPLE CREATIVE TECHNOLOGY Technical Specifications 7 4 Operating Using Serial Commands To operate your device using serial commands install Kramer s control software K Router that can be downloaded from the Kramer Electronics Web site For an explanation of the RS 232 protocol and all serial commands see section 10 Technical Specifications The VS 120 technical specifications are shown in Table 3 Table 3 VS 120 Technical Specifications INPUTS 20 video 1Vpp 75Q on BNC connectors 20 audio stereo 1Vpp 50kQ on RCA connectors OUTPUTS 1 video 1Vpp 75Q on 2 BNC connectors connected in parallel 1 audio stereo 1Vpp 100Q on 2x2 RCA connectors connected in parallel RS 232 on a 9 pin D sub connector RS 485 on a 3 pin terminal block connector DISPLAY 4 seven segment display LEDs 20 LED status display CONTROL 12 key keypad control 17 touch switch setup controls RS 232 RS 485 SWITCHING Vertical interval DWELL TIME 1 60s ERROR DETECTION Sync detection VIDEO BANDWIDTH 25MHz 3dB AUDIO BANDWIDTH 20kHz 1dB DIFF GAIN 1 3 K FACTOR lt 0 05 DIMENSIONS 19 x 7 x 2U W D H rack mountable POWER SOURCE 230V AC 50 60Hz 115V AC U S A 6 7VA WEIGHT 4 1kg 9 1lbs approx ACCESSORIES Power cord Windows based control software null modem adapter 1 www kramerelectroni
6. shield may be connected to the right G Ground PIN on one of the units for example on the master To connect up to 98 additional VS 120 slave units via RS 485 do the following see Figure 4 e Connect the RS 485 terminal block port on the first VS 120 unit to the RS 485 port on the second VS 120 unit and so on connecting all the RS 485 ports e Set the Self Address of the first machine to 01 the second machine to 02 and so on up to 99 see section 6 1 2 Operating the VS 120 7 1 7 1 RS 232 Master Slave Slave Self Address 1 Self Address 2 Self Address 99 N aig Cnr RS 485 Figure 4 PC Controlling Multiple VS 120 Units Operating the VS 120 This section describes how to operate the VS 120 e Asa switcher see section 7 1 e Asa scanner see section 7 2 e detect input errors see section 7 2 3 e In multiple unit configurations see section 7 3 e Using RS 232 RS 485 serial commands transmitted by a touch screen system PC or other serial controller see section 7 4 Operating the VS 120 as a Switcher The VS 120 operates as a 20 x 1 switcher when set to Manual mode Any of the 20 inputs can be individually selected and routed to the output When Manual mode is selected it prevents the scanning function from operating 1 Choosing Manual Mode To set the Man
7. 120 20 x 1 Sequential Video Audio Switcher is a programmable scanning video switcher that accepts up to 20 inputs when operating as a standalone unit sequentially cycling the 20 video and audio stereo sources In manual mode it operates as a switcher and in automatic mode it operates as a scanner The fully programmable EEPROM NOVRAM memory saves and recalls all user defined setups Specifically the VS 120 20 x 1 Sequential Video Audio Switcher features e Support for connecting up to 99 VS 120 units to form a switcher scanner with up to 1980 inputs e Control via the front panel buttons or by RS 232 or RS 485 commands transmitted by a PC touch screen system or other serial controller e Switching during the vertical interval to ensure glitch free transitions between genlocked sources e Fully microprocessor controlled operation To achieve the best performance e Use only good quality connection cables to avoid interference deterioration in signal quality due to poor matching and elevated noise levels often associated with low quality cables e Avoid interference from neighboring electrical appliances that may adversely influence signal quality and position your Kramer VS 120 away from moisture excessive sunlight and dust 1 Available from Kramer Electronics on our Web site at http www kramerelectronics com 3 Overview Q Oe e E ANC 46666656668665665868 E oOo 4 5 6 a L L ENABLED INPUTS MAC
8. ARRANTY SERVICE 1 To obtain service on you product you must take or ship it prepaid to any authorized Kramer service center 2 Whenever warranty service is required the original dated invoice or a copy must be presented as proof of warranty coverage and should be included in any shipment of the product Please also include in any mailing a contact name company address and a description of the problem s 3 For the name of the nearest Kramer authorized service center consult your authorized dealer LIMITATION OFIMPLIED WARRANTIES All implied warranties including warranties of merchantability and fitness for a particular purpose are limited in duration to the length of this warranty EXCLUSION OFDAMAGES The liability of Kramer for any effective products is limited to the repair or replacement of the product at our option Kramer shall not be liable for 1 Damage to other property caused by defects in this product damages based upon inconvenience loss of use of the product loss of time commercial loss or 2 Any other damages whether incidental consequential or otherwise Some countries may not allow limitations on how long an implied warranty lasts and or do not allow the exclusion or limitation of incidental or consequential damages so the above limitations and exclusions may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from place to place NOTE All prod
9. HINE INPUT Down UP 7 8 9 ed E o o o o 000 0000 OOOO 0000 PRoORAM Kr p Auto MANUAL Owe START CONTINUE Mone ENABLE DISABLE SKIP STOP IGNORE ust 20x1 Sequential Video Audio Switcher Front Panel 8 9 40 11 12 13 44 45 16 17 18 19 20 21 22 19 Audio Outputs Loo 18 20 ideo ideo HEN IEN AN HEN AEAN AA PEN 7 N P Ai A AA uU 9 WA 9 DUI 0 ECF N JN WA SA SS Ne S N WY 4 5 7 1 i 1 15 7 Figure 1 VS 120 20 x 1 Sequential Video Audio Switcher KRAMER SIMPLE CREATIVE TECHNOLOGY Overview Table 1 Front Panel Features and Functions of the VS 120 Feature Function 1 POWER Switch Illuminated switch for turning the unit ON or OFF 2 PROGRAM KEYS Buttons Use to set the values for the Machine Number Input Number or Dwell Time 3 ENABLED INPUTS LEDs Indicate whether an input is enabled on or disabled off 4 MACHINE 7 segment Display Displays the Machine Number 5 INPUT 7 segment Display Displays the nput Number 6 DOWN Button Press to decrease a number by one 7 UP Button Press to increase a number by one 8 SELF ADDRESS Button Sets
10. Kramer Electronics Ltd USER MANUAL Model VS 120 20 x 1 Sequential Video Audio Switcher Contents Contents 1 Introduction 2 Getting Started 2 1 Quick Start 3 Overview 4 Installing the VS 120 in a Rack 5 Connecting the VS 120 6 Controlling the VS 120 6 1 Controlling via the RS 232 Port 6 1 1 Connecting the RS 232 Port 6 1 2 Setting the Self Address 6 2 Controlling via the RS 485 Port 7 Operating the VS 120 7 1 Operating the VS 120 as a Switcher 7 1 Choosing Manual Mode 7 1 2 Routing an Input 7 1 3 Enabling and Disabling Inputs 7 2 Operating the VS 120 as a Scanner 7 2 1 Choosing Auto Mode 7 2 2 Scanning the Inputs 7 2 3 Detecting Errors Ta Operating Multiple VS 120 Units 7 3 1 Viewing the Configuration of Another Machine 7 3 2 Routing an Input from Another Machine 7 4 Operating Using Serial Commands 8 Technical Specifications 9 Hex Table 10 RS 232 Communication Protocol for the VS 120 Figures Figure 1 VS 120 20 x 1 Sequential Video Audio Switcher Figure 2 Connecting the VS 120 Figure 3 Connecting a PC without using a Null modem Adapter Figure 4 PC Controlling Multiple VS 120 Units Figure 5 Multiple Unit Configuration NAA U Nm E See eB eee ee eee BRWWNHNNNrFK OTC S amp S uN ee ROMAN Contents Tables Table 1 Front Panel Features and Functions of the VS 120 Table 2 Rear Panel Features and Functions of the VS 120 Table 3 VS 120 T
11. be the Machine number that is influenced by COMMAND The number of machine can be from 1 to 99 hex 1 Master Byte 2 bit 7 must be 1 Byte 3 Byte 3 bits 0 to 6 DATA These bits describe the DATA that is influenced by COMMAND For example to connect input 17 to output the DATA should be 17 hex Byte 3 bit 7 must be 1 Table 5 Instruction Codes for VS 120 Protocol Note All values in the table are hex unless otherwise stated Code Command Address Data Replay 00 CONNECT INPUT TO OUTPUT Machine number Input number Nonessential 01 GET STATUS WHICH INPUT IS 0 0 COMMAND As sent 01 CONNECTED TO OUTPUT ADDRESS Machine connected DATA Input number 02 SET ALL MACHINES TO AUTO 0 1 Auto Nonessential OR MANUAL MODE 0 Manual 03 GET THE STATUS OF 0 0 COMMAND As sent 03 MACHINES AUTO OR MANUAL ADDRESS As sent MODE DATA 1 for Auto mode 0 for Manual mode 04 SET DWELL TIME OF SCANNING 0 2 99 Nonessential 05 GET DWELL TIME OF SCANNING 0 0 COMMAND amp ADDRESS As sent DATA Dwell time 2 99 06 START SCANNING 0 0 Nonessential 08 STOP SCANNING 0 0 Nonessential 09 CONTINUE SCANNING 0 0 Nonessential 0A ENABLE INPUT FOR SCANNING Machine number Input number Nonessential 0B DISABLE INPUT FOR SCANNING Machine number Input number Nonessential 0C GET THE STATUS OF INPUT Machine number Input number COMMAND
12. cs com 15 Hex Table 9 10 Hex Table Table 4 lists the Hex values for the VS 120 see section 10 for more detail Table 4 VS 120 Hex Table Inputs Switch Commands Inputs Switch Commands Hex Hex IN 1 40 80 81 IN 11 40 80 8B IN2 40 80 82 IN 12 40 80 8C IN3 40 80 83 IN 13 40 80 8D IN 4 40 80 84 IN 14 40 80 8E IN5 40 80 85 IN 15 40 80 8F IN 6 40 80 86 IN 16 40 80 90 IN 7 40 80 87 IN 17 40 80 91 IN8 40 80 88 IN 18 40 80 92 IN 9 40 80 89 IN 19 40 80 93 IN 10 40 80 8A IN 20 40 80 94 RS 232 Communication Protocol for the VS 120 RS 232 communication with the VS 120 is done using three bytes of information as defined below The data rate is 9600 baud no parity 8 data bits and one stop bit Byte 1 COMMAND 0 x x x x x x x 7 6 9 4 3 2 1 0 Byte 2 ADDRESS 1 x x x x x x x 7 6 5 4 3 2 1 0 Byte 3 DATA 1 x x x x x x x 7 6 5 4 3 2 1 0 DETAILED DESCRIPTION Byte 1 Byte 1 bits 0 5 COMMAND number CODE listed below Byte 1 bit 6 Destination bit When the PC sends a message to the machine this bit must be 1 When the machine sends a message to the PC this bit must be 1 If this bit is O this message is not destined for the PC Byte 1 bit 7 must be 0 16 KRAMER SIMPLE CREATIVE TECHNOLOGY RS 232 Communication Protocol for the VS 120 Byte 2 Byte 2 bits 0 to 6 ADDRESS These bits descri
13. echnical Specifications Table 4 VS 120 Hex Table Table 5 Instruction Codes for VS 120 Protocol 15 16 17 ii KRAMER SIMPLE CREATIVE TECHNOLOGY Introduction 1 Introduction Welcome to Kramer Electronics Since 1981 Kramer Electronics has been providing a world of unique creative and affordable solutions to the vast range of problems that confront the video audio presentation and broadcasting professional on a daily basis In recent years we have redesigned and upgraded most of our line making the best even better Our 1 000 plus different models now appear in 11 groups that are clearly defined by function Thank you for purchasing the Kramer TOOLS VS 120 20 x 1 Sequential Video Audio Switcher which is ideal e Asa sophisticated alarm camera scanner e For monitoring large duplication systems e For automatic error detection in security systems Each package includes the following items e VS 120 20 x 1 Sequential Video Audio Switcher e Power cord e Windows based Kramer control software e Null modem adapter e This user manual 2 Getting Started We recommend that you e Unpack the equipment carefully and save the original box and packaging materials for possible future shipment e Review the contents of this user manual e Use Kramer high performance high resolution cables 1 GROUP 1 Distribution Amplifiers GROUP 2 Switchers and Matrix Switchers GROUP 3 Control Systems GROUP 4 Fo
14. for Enable ENABLE OR DISABLE 0B for Disable SCANNING ADDRESS amp DATA As sent 16 SAVE THE STATUS OF INPUT Machine number 0 Nonessential ENABLE OR DISABLE SCANNING 00 SET ERROR STATUS SKIP 0 0 Skip Nonessential STOP OR IGNORE 1 Stop 2 Ignore 0E GET ERROR STATUS SKIP 0 0 COMMAND amp ADDRESS As sent STOP OR IGNORE DATA 0 for Skip 1 for Stop 2 for Ignore OF GET THE NUMBER OF LIST OF 0 0 COMMAND amp ADDRESS As sent ERROR DATA Number of errors 10 GET ERROR NUMBER X 0 Error number COMMAND As sent 0 LAST ERROR ADDRESS Machine number DATA Input number of error 12 DELETE ALL ERRORS 0 0 Nonessential 17 RS 232 Communication Protocol for the VS 120 EXAMPLES FOR USING THE PROTOCOL 1 To connect input 8 in machine 2 to the output set the bytes as below Byte 1 40 hex COMMAND 40 00 40 hex Byte 2 80 hex ADDRESS hex 80 02 82 hex Byte 3 80 hex DATA hex 80 08 88 hex 2 To change the machines status to Auto mode set the bytes as below Byte 1 40 hex COMMAND 40 02 42 hex Byte 2 80 hex ADDRESS hex 80 00 80 hex Byte 3 80 hex DATA hex 80 01 81 hex 3 To get the Dwell time of scanning set the bytes as below Byte 1 40 hex COMMAND 40 05 45 Byte 2 80 hex ADDRESS hex 80 00 80 hex Byte 3 80 hex DATA hex 80 00 80 hex Reply The reply to this comma
15. gether to create one output for the multi unit machine Output gt 0950509 6598 Up to 99 Units e gt Self Address 1 Inputs 1 20 Self Address 2 Inputs Figure 5 Multiple Unit Configuration 7 3 1 Viewing the Configuration of Another Machine The configuration of any machine can be viewed from any other machine to see which inputs are enabled or disabled To view the configuration of another target machine 1 In Manual mode press the MACHINE NUMBER button in the PROGRAM section The MACHINE display and the AUTO and MANUAL LEDs flash Enter the address of the target machine using the UP or DOWN buttons or the PROGRAM KEYS and press ENT The AUTO and MANUAL LEDs stop flashing The MACHINE display also stops flashing and shows the address of the target machine The LEDs of the Enabled Inputs display the active inputs on the target machine 7 3 2 Routing an Input from Another Machine To route an input from a target machine in Manual mode 1 Using the PROGRAM KEYS the UP and DOWN keys won t allow selection of a different machine enter the desired output from 01 to 20 on the target machine The input display shows the target input and the MACHINE display flashes Enter the target machine address using the PROGRAM KEYSS and press ENT The MACHINE display stops flashing and the target input is routed to the
16. hrough each of the four holes in the rack ears Note that some models the front panel may feature built in rack ears e Detachable rack ears can be removed for desktop use e Always mount the machine in the rack before you attach any cables or connect the machine to the power e If you are using a Kramer rack adapter kit for a machine that is not 19 see the Rack Adapters user manual for installation instructions you can download it at http www kramerelectronics com KRAMER SIMPLE CREATIVE TECHNOLOGY Connecting the VS 120 5 Connecting the VS 120 To connect VS 120 as shown in Figure 2 do the following 1 Connect up to 20 video audio stereo sources to the appropriate input video BNC connectors and input AUDIO L and AUDIO R RCA connectors for example video players to 20 2 Connect the output video BNC connectors for example to one or two displays and output AUDIO L and AUDIO R RCA connectors to up to two audio stereo acceptors for example the amplifier 3 Ifrequired you can connect a PC and or controller to the RS 232 or RS 485 ports as shown below To combine multiple units connect them using the RS 485 ports 4 Connect the power cord to the mains electricity not shown in Figure 2 Video PI Video Player 20 Figure 2 Connecting the VS 120 1 Switch OFF the power on each device before connecting it to your VS 120 After connecting your VS 120 switch o
17. l s characteristics lights the Ignore LED 22 LIST Button Press to produce a list during the first scanning cycle of the video inputs at which a video signal is absent Table 2 Rear Panel Features and Functions of the VS 120 Feature Function 23 AUDIO INPUTS RCA Connectors Connects to the left and right audio sources from 1 to 20 24 Video Inputs BNC Connectors Connects to the video sources from 1 to 20 25 Video Outputs Loop BNC Connectors Connects to the video acceptor s from 1 to 2 26 RS 485 Terminal Block Port Detachable terminal block port PINOUT from left G 27 Audio Outputs Loop RCA Connectors Connects to the left and right audio connectors on the acceptor s next unit from 1 to 2 28 Power Connector with Fuse AC connector enabling power supply to the unit 29 RS 232 DB 9F Port Connect to the PC or the Remote Controller via a null modem connection Installing the VS 120 in a Rack 4 Installing the VS 120 in a Rack This section describes how to install the VS 120 in a rack Before Installing in a rack How to Rack Mount Before installing in a rack be sure that the environment is within the recommended range Operating temperature range 5 to 45 C 412 to 113 Operating humidity range 10 to 90 RHL non condensing Storage temperature range 20 to 702 C 4 to 158 Storage humidity range 5 to 95 RHL non condensing
18. n its power and then switch on the power on each device Controlling the VS 120 6 Controlling the VS 120 Operate the VS 120 via the front panel buttons You can also control the VS 120 using the e RS 222 port see section 6 1 e RS 485 port see section 6 2 6 1 Controlling via the RS 232 Port The VS 120 can be operated via PC touch screen or serial controller by means of serial commands transmitted through the RS 232 port For a description of the serial commands see section 10 6 1 1 Connecting the RS 232 Port To connect a PC to the VS 120 unit using the null modem adapter provided with the machine recommended e Connect the RS 232 9 pin D sub rear panel port on the Master VS 120 unit to the null modem adapter and connect the null modem adapter with a straight cable to the RS 232 9 pin D sub port on your PC To connect a PC to the VS 120 unit without using a null modem adapter e Connect the RS 232 9 pin D sub port on your PC to the RS 232 9 pin D sub rear panel port on the Master VS 120 unit using a cable illustrated in Figure 3 PIN 5 Connected to PIN 5 Ground PIN 3 Connected to PIN 2 PIN 2 Connected to PIN 3 Female DB9 From PC Male DB9 PIN 4 Connected to PIN 6 PINS 8 7 1 Connected together If a Shielded cable is used connect the shield to PIN 5 Figure 3 Connecting a PC without using a Null modem Adapter 1 Or a master program remote control system such as the Kramer RC 3000 8
19. nd is identical to the three bytes which were sent For example Byte 1 45 hex Byte 2 80 hex Byte 3 94 hex Therefore the Dwell time 94 hex 80 hex 14 hex 20 dec 4 To start scanning set the byte as below Byte 1 40 COMMAND 40 06 46 hex Byte 2 80 hex ADDRESS hex 80 00 80 hex Byte 3 80 hex DATA hex 80 00 80 hex Notes 1 Use the COMMAND Connect input to Output only in Manual mode 2 Use the COMMAND Start scanning or Continue scanning only in Auto mode 3 The two LEDs of Auto and Manual go out when using the COMMAND Enable input for scanning or Disable input for scanning until using the COMMAND Save the status of inputs Enable or Disable scanning 4 Use the COMMAND Save the status of inputs Enable or Disable scanning after using the COMMANDS Enable input for scanning and Disable input for scanning KRAMER SIMPLE CREATIVE TECHNOLOGY LIMITED WARRANTY Kramer Electronics hereafter Kramer warrants this product free from defects in material and workmanship under the following terms HOW LONGIS THE WARRANTY Labor and parts are warranted for seven years from the date of the first customer purchase WHOIS PROTECTED Only the first purchase customer may enforce this warranty WHAT IS COVERED AND WHAT IS NOT COVERED Except as below this warranty covers all defects in material or workmanship in this product The following are not
20. nics com E mail info kramerel com P N 2900 002026 REV 3
21. put 1 Press the INPUT NUMBER button in the PROGRAM section The INPUT display and the AUTO and MANUAL LEDs flash Enter the desired input and press DISABLE to disable the input The ENABLED INPUTS LED turns off Then press ENT The AUTO and MANUAL LEDs stop flashing and the MANUAL LED is steadily on To enable an input 1 Press the INPUT NUMBER button in the PROGRAM section The INPUT display and the AUTO and MANUAL LEDs flash Enter the desired input and press ENABLE to disable the input The input LED turns on Then press ENT The AUTO and MANUAL LEDs stop flashing and the MANUAL LED is steadily on 11 Operating the VS 120 7 2 7 2 1 7 2 2 Operating the VS 120 as a Scanner The VS 120 operates as a 20 input scanner when set to Auto mode The VS 120 scans all enabled inputs one after another for the amount of time programmed in the Dwell Time setting and routes the input to the output Any enabled input that does not have a video signal is logged in the Error List memory that can later be displayed When Auto mode is selected it prevents the switching function from operating Choosing Auto Mode To set Auto mode e Press the AUTO button in the SETUP section The AUTO LED illuminates Scanning the Inputs Dwell time determines how long each input is displayed during the scan To set the dwell time 1 Press DWELL TIME button in the AUTO MODE section The MACHINE display flashes 2 Se
22. rmat Standards Converters GROUP 5 Twisted Pair Solutions GROUP 6 Specialty AV Products GROUP 7 Scan Converters and Scalers GROUP 8 Cables and Connectors GROUP 9 Room Connectivity GROUP 10 Accessories and Rack Adapters GROUP 11 Sierra Products 2 We recommend that you use only the power cord supplied with this device 3 Download up to date Kramer user manuals from our Web site at http www kramerelectronics com 4 The complete list of Kramer cables is on our Web site at http www kramerelectronics com 1 Getting Started 2 1 Quick Start This quick start chart summarizes the basic setup and operation steps Step 1 Mount the machine see section 4 Mount the machine in a rack or stick the 4 rubber feet to the underside Master Self Address 1 Slave Self Address 2 Video Player 20 Slave Self Address 99 Outputs Step 3 Connect the control see section 6 If required connect an RS 232 or an RS 485 Control Fort Step 4 Turn the power ON Step 5 Set the machine see section 6 Set the Self Address Standalone or Master unit to O1 Slave unite to other unique addresses Step 6 Operate the machine see section 7 Operate e Via the front panel buttons RS 485 or RS 232 e Ae a ewitcher in Manual mode e Ae a scanner in Auto mode 2 KRAMER SIMPLE CREATIVE TECHNOLOGY Overview 3 Overview The VS
23. t the dwell time in seconds from 2 to 99 by pressing the UP DOWN keys or the PROGRAM KEYS 3 Press ENT to save the number To begin an automatic scan e Press the START button in the AUTO MODE section The Input display begins to increment automatically as it scans the inputs and the AUTO LED flashes To stop the scan e Pressthe STOP button in the AUTO MODE section The Input display stops on an input and the AUTO LED illuminates steadily To continue the scan from the displayed input e Press the CONTINUE button in the AUTO MODE section The Input display increments from the displayed input and the AUTO LED flashes To restart the scan from input 01 e Press the START button in the AUTO MODE section The Input display begins to increment automatically as it scans the inputs and the AUTO LED flashes KRAMER SIMPLE CREATIVE TECHNOLOGY Operating the VS 120 7 2 3 Detecting Errors 7 3 While scanning the VS 120 senses missing video inputs illuminates the LIST LED in the ERROR section and stores the errored input number in memory The list is erased and initialized every time a new scan is begun To stop an active scan when an error is detected e Press the STOP button in the Error section The STOP LED illuminates when an error is detected and the scan is stopped To skip an errored input e Press the SKIP button in the Error section The SKIP LED illuminates when an error is detected and the scan continues To
24. the Machine between 1 and 99 Set a standalone machine address to 01 9 Ej AUTO Button Press to activate the scanner mode Prevents using the unit as a o switcher and lights the Auto LED 10 MANUAL Button Press to activate the default switcher mode Prevents using the unit as a scanner and lights the Manual LED 11 DWELL TIME Button Sets the scan display time range is between 2 and 99 seconds and flashes the current setting in the MACHINE Display 12 START Button Starts scanning only if the AUTO LED lights from the first input of the 3 first machine that is in the Enable state Dwell Time determines the eS scanning time 13 lt STOP Button Stops the scanning 14 CONTINUE Button Starts scanning from the present connected input to the output functions only when the AUTO LED lights 15 MACHINE NUMBER Use to display another machine in a multiple unit configuration Button 16 S NPUT NUMBER Button Press to alter the Enable Disable status of an input The current 9 Input Number flashes in the INPUT Display 17 ENABLE Button Press to light the selected Enabled Inputs LED 18 DISABLE Button Press to turn off the selected Enabled Inputs LED 19 SKIP Button Skips an input after detecting a video input error during scanning lights the Skip LED and continues scanning the next input 20 STOP Button Stops scanning after detecting a video input error lights the Stop 5 LED 21 IGNORE Button Scans independently of the video input signa
25. ual mode e Press the MANUAL button in the SETUP section The MANUAL LED illuminates 7 1 2 Routing an Input To route an input to the output 1 Choose an input by pressing UP or DOWN buttons to increment or decrement the number in the INPUT display then press ENT or Enter the input as a 2 digit number 01 02 20 on the PROGRAM KEYS pad the MACHINE display flashes then press ENT KRAMER SIMPLE CREATIVE TECHNOLOGY Operating the VS 120 2 To optionally choose a different machine if using a multiple unit configuration enter the 2 digit input number on the PROGRAM KEYS pad When the MACHINE display flashes enter the target machine number then press ENT If the MACHINE display already shows the number of the required machine you can press ENT immediately without pressing the Machine Example 1 If input 13 on machine 1 is connected to the output and you want to connect input 5 to the output press 0 followed by 5 and then ENT Example 2 If input 13 on machine 1 is connected to the output and you want to connect input 7 of machine 2 to the output press 0 followed by 7 and then 0 followed by 2 and then press ENT 7 1 3 Enabling and Disabling Inputs You can enable or disable individual inputs by programming The setup is stored in non volatile memory and is saved when the unit is powered off When an input is enabled its LED illuminates in the ENABLED INPUTS section To disable an in
26. ucts returned to Kramer for service must have prior approval This may be obtained from your dealer This equipment has been tested to determine compliance with the requirements of EN 50081 Electromagnetic compatibility EMC generic emission standard Part 1 Residential commercial and light industry EN 50082 Electromagnetic compatibility EMC generic immunity standard Part 1 Residential commercial and light industry environment CFR 47 FCC Rules and Regulations Part 15 Radio frequency devices Subpart B Unintentional radiators CAUTION BO Servicing the machines can only be done by an authorized Kramer technician Any user who makes changes or modifications to the unit without the expressed approval of the manufacturer will void user authority to operate the equipment BO Use the supplied DC power supply to feed power to the machine BO Please use recommended interconnection cables to connect the machine to other components 19 For the latest information on our products and a list of Kramer distributors visit our Web site www kramerelectronics com where updates to this user manual may be found We welcome your questions comments and feedback Safety Warning Disconnect the unit from the power supply before opening servicing Caution 001 Ey lt 4 M Toc jg Institute of Quality amp Control Q KA d Quality Kramer Electronics Ltd Web site www kramerelectro