1. SB K02 Digital Keypad TheSB KO2uses the latest microprocessor technology to operate door strikes and security systems that require a momentary timed or latching dry contact closure All programming is done through the keypad Codes and operating parameters are stored within the microprocessor and can not be lost due to power failure The SB K02can store 1000 prox cards and user 4 digit codes Each 4 digit code has 10 000 possible combinations The unit has one relay with 5 Amp contacts CONTENTS Page INtFOGUCTION Late ed nec din de secea sa A e e e ayra 2 Product Specifications 00 0 0 cece eee e cette eee eeeeneeeeeeeeeeaeegs 3 Intramural Interface Circuit ccc cece eee ee eee ceeeeeeeeeeeeeeeeaees Mounting amp PCB Diagram 0 ccceeeeee ener eee n eee ee teeta eenen ned 4 Wiring Diagram oreesa teed OA iet hae NE N EEA 4 5 Engineer Programming Information and Notes n 5 Engineer Programming Factory Default Setting cee eeeeeee eee eeeeea ee eeeeaeeeees 6 Changing Master amp User Codes cceeeceeeeeeeeeeeeees 7 Setting Functions of Master amp User ecce 7 Set Door Relay Strike ccc ceeeeee eee cee eee eee eeeeeneeeeeaeeaeeee 7 Set Door Open Detection Time cccceeeeeeeeeeeeeeees 8 Security Arrangement e ce ceeeee eee e eee ee eaten ee eeeeeee een eed 9 Exit Engineer Programming Mode 9 Resetting Non Volatile Memory 9 Inst
2. aller Information amp Notes s e eneen 9 Technical Specifications cccececec cence eeee eee ee ee rrer ereenn 10 Specifications 1 Programmable Functions Relay latching or momentary Relay activate independently or together Change Codes 1 master 1000 users amp prox cards Door open detection Programmable Timers Door relay time 00 99 seconds Door open detection 00 99 seconds Alarm time 00 99 minutes Wiring Connections Electric lock External bell External Push Switch Magnetic Contacts Alarm 4 Keypad 12 keys 5 Programming memory Non volatile Eeprom memory IMPORTANT INFORAMTION There are no user serviceable parts contained within the SB K02access control keypad If holes are to be drilled before mounting onto a wall check for hidden cables and or pipes before drilling Use safety goggles when drilling or hammering in cable clips Every effort has been made to provide accurate information however slight variations can occur We also reserve the right to make changes for product improvement at any time NOTE PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING TO INSTALL THE SB K02 Intramural Interface Circuit 1 Alarm output interface See Figure 1 2 Electric lock interface See Figure 2 5V ALARM gt Figure 1 Figure 2 1 Attach the rear plate to a single or double gang electrical box or secure to the wall firmly with at least three flat head screw
3. d Accept LED illuminated Open LED flashing Note Press to save changes and exit engineer programming when all programming has been completed otherwise changes will not be saved Changing Master amp User Codes In engineer programming mode Nn To change Master code Press 0 new master codel re enter new master code Upon acceptance Open LED illuminates and stops flashing Press after changing the master code otherwise unit will disregard the new code and revert back to the factory default code Note the master code must be 4 8 digit number Adding User Codes amp Cards To Add User cards amp codes Press 1 read card user identification Note the user identification must be 3 digit number if adding more than 1 card read the next card after inputting the 3 digit code for the previous card when you have finished adding all cards press the key 1 card must be 000 up to 999 Then the BC 2000 control station added a user card it was auto added a user code with 1234 Delete User Card or Cards There are 3 options to delete a user card or cards in engineering mode a Press 2 0000 to delete all user cards b Press 2 read card to delete individual user card c Press 2 user identification number to delete individual user card User Operation Mode There are 3 d
4. ght 100mA quiescent maximum 5Amp 12Vdc 150mA pull current Negative loop normally closed 1 Master 1000 cards and 1000 codes 12 keys 3 LED status indicators EM or EM compatible 5 8cm Electric lock Remote door control Door open detection External door bell External Alarm Non volatile eeprom memory 0 C to 60 C 32 F to 140 F Metal 128mm x 82mm x 28mm 500g Package Listing Name Model no Quantity Remark Digital Keypad SB K02 1 User Manual SB K02 1 Flat Head Screws P 3mmx6mm 1 Used for front case and back case Pastern Stopper Self Tapping Screws 6mmx27 mm 3 5mmx27 mm Used for fixing Used for fixing
5. ifferent options for user operation mode card only card and password valid code The optioned used is common to all users Press 3 00 valid card only Press 3 01 valid card and password Press 3 02 valid card or password Setting Door Relay Strike Time The door relay output can be operated as either normally opened or normally closed a maximum current of 10 ampere can pass through the relay if used as normally opened or 5 ampere if normally closed The door relay time can be set from 0 seconds to a maximum of 99 seconds The factory default setting is 6 seconds and can be changed through the keypad Press 4 new time from 00 99 seconds Setting Alarm Signal Output Time Press 5 new time from 00 99 minutes Setting Door Open Detection Press 6 00 to disable this function factory setting Press 6 01 to enable this function In order for this feature to work door contacts must be connected There are 2 programming functions that work together in this mode a If door not closed after opening keypad buzzer sounds b If door forced open keypad buzzer sounds and sends alarm signal Setting Security Arrangement There are two levels of keypad security available for the SB K02 Press 7 01 to read 10 invalid ca
6. rds or valid cards then enter 4 wrong passwords in succession the keypad is locked for 10 minutes Press 7 02 to read 10 invalid cards or valid cards then enter 4 wrong passwords in succession the keypad activates and alarm signal To disable this feature Press 7 00 factory default setting Resetting To Factory Default Setting To revert all settings to the factory default values then the Non Volatile Memory Eeprom must be reset Reset Non Volatile Memory by switching of the power and placing the jumper connector onto the pins 1 amp 2 as per figure 2 After switching power on remove jumper the BC 2000 will give a beep and is now reset to factory default values Changing User Password Code The factory default setting for each user password code 1234 this can be modified so that each user has a unique individual 4 digit code Press read user card user passoword new password re enter new password Using Password Code to release the door Press user passoword Technical Specification DC Supply Voltage Low voltage input 12 10 Vdc unregulated Current Consumption Door Relay Alarm output load Tamper Protection Codes Keypad Card Types Induction Distance Wiring Connections Memory Operating Temperature Keypad Housing Dimensions Wei
7. s 2 When wiring has been completed attach the front cover to the rear plate Figure 3 Figure 4 The front cover can be permanently secured by using the short screw supplied SB K02 Printed Circuit Board Wiring 1 Unplug the cable harness and connect the necessary cables See Figure 5 2 Tape any wires that are unused 3 Plug the cable harness See Figure 5 4 Attach the front cover See Figure 3 Terminal Wire Connector 1 Function 10 Green Invalid 9 White Invalid 8 ALARM Grey Alarm output 7 OPEN Yellow To Door Remote Control Button Then Negative 6 D_IN Brown To Door Contact Then To Door In 5 12V Red 12Vdc Positive Regulated Power Input 4 GND Black Negative Regulated Power Input 3 NO Blue Door Strike Relay N O 2 COM Purple Door Strike Relay Com 1 NC Orange Door Strike Relay N C DO NOT PLUG ADAPTOR OUR TRANSFORMER INTO MAINS UNTIL ALL WIRING HAS BEEN COMPLETED AND THE FRONT COVER SECURED SB K02 cnn Tu GND HN 12V SB K02 2 i BR 1 2V 3A Figure 5 Power Up 1 After all wiring is complete and the unit face plate is attached to the back plate apply 12Vdc power to the unit Accept LED the yellow LED flashing Engineer Programming Mode To enter programming mode Press 9999 within 5 seconds Ready the green LED an

Download Pdf Manuals

image

Related Search

Related Contents

Guidelines on Prevention of Communicable Diseases in Residential  DÉAMBULATEUR XXL  据付工事説明書  Catalogue - Motion Control Products  MD5 - Deutsch Deutsch - MD5  Manual do usuário - Nagao Racing Suspensões Especiais  SX4750 Swinging Bucket Rotor  Mode d`emploi  DX-450HM/460HM Operation-Manual DE FR ES - NEW HiFi    