BPT322 user manual
Contents
1. PROG PROGRAMMING You can set 9 weekly programs with 6 temperature changes per day The Pr1 and Pr2 programs are empty Pr3 to Pr7 programs are set by default The PrU and PrL are also set by default intended for the EVEN ODD week option for details see page 6 Change in the program settings Press twice the MENU button choose the PROG mode by turning the button and press the gs button to confirm The selected program number is flashing on the display Turning the button choose the program which you want to change and press the button to confirm Turning the button choose the number of days to be programmed you can program day by day or 1 5 Mon Fri 6 7 Sat Sun or 1 7 Mon Sun and press the button to confirm The 1st change time starts flashing set the time by turning the button and press the button to confirm Set the temperature for this time by turning the button and press again the button to con firm The 2nd change time appears on the display Proceed in the same way as with the first change setting In this way you can set up to 6 temperature changes per day To return one step back shortly press the aoe button to return to the main menu press the button long After changing the preset program check whether all the changes made conform to your requirements It is not necessa
2. GST type external not included in the 9 dBm SMA connector H SN MPe61 1032894210 ni AN IMET 012207003886782 a L L U RESET press this button with MENU butto for restoring to default settings see page 8 CE 0980 A Nea Me pe FOC ID UDU 8912142009007 iR press MENU x BPT32 GST ELEKTROBOCK Cz Connector for power supply No 1 for the ADO5 jack power supply gt included in the packing SIM card holder space for inserting the SIM card __t___ the SIM card is not included in the packing Connector for external sensor turning short press long press packing can be purchased separately order No 1330 on www elbock cz Controls change of temperature setting selection entry confirmation quick change of required temperature or program see page 10 viewing other information See page 10 step back only in the CONST mode see page 7 opening the main menu or returning a step back Type ADO5 jack 5V DC 2 5A Open the SIM card holder and insert the SIM card in the direction indicated then close the holder again can be used with sensors ae order No 0012 CTO1 10k order No 0015 or CTO2 10k order No 0013 Connector for power supply No 2 for power source installed in a wiring box not included in the packing Backup batteries room to backup the time running always use
3. O O O included in the packing type ADO5 Jack 5V DC 2 5A In case of guarantee or post guarantee service send the thermostat including proof of purchase to the manufacturer s CERTIFICATE OF GUARANTEE address The guarantee does not cover faults resulting from uarantee period for the product amounts to 2 years 9 scale incompetent installation or interference in the device design DECLARATION OF CONFORMITY stamp of shop We ELEKTROBOCK CZ s r o herewith declare that the product BPT322 GST conforms to the basic requirements and other ined by a corresponding provisions of the Directive 1999 5 EC Issued 01 04 2012 on www elbock cz ELEKTROBOCK CZ s r o X z4 Blanensk 1763 HA Ku im 664 34 Tel 420 541 230 216 D AN ELEKTROBOCK CZ NX cS MADE IN CZECH REPUBLIC www elbock cz Mern m product No date of sale
4. MINIMUM SWITCH ON TIME factory setting of 2 min Here you can set the minimum switch on time of the boiler in minutes at hysteresis Select within the range from 1 to 5 minutes according to the type of the heating system used see the table Set the value by turning the button and confirm with the button 6 SETTING PI CONTROL PARAMETERS PI CONTROL INTERVAL Select according to the objec s thermal inertia The optimum setting usually falls within the range of 10 to 15 min The adjustable range is 5 min to 20 min by 1 min factory setting of 10 min Set the interval by turning the button and confirm with the button MINIMUM SWITCH ON TIME factory setting of 2 min Select within the range of 1 to 5 minutes The setting is given by the heating system type and depends on the Pl control time period selection Setting according to the table is recommended Set the value by turning the button and confirm with the button PI CONTROL BAND factory setting of 2 C TThis value determines the temperature at which the Pl control starts functioning For example the desired temperature is 22 C the proportional band is 1 5 C Up to 20 5 C the source heats fully When this value is reached the Pl control starts The PROPORTIONAL band can be set within the range of 0 5 to 3 0 C by 0 1 C Set the PI band by turning the button and confirm with
5. C CONST Set the value by turning the button and press the button to confirm 4 MAX TEMP C 4 CONTROL TYPE PID control set by default Selection of the control type CONST Choose the type of control by turning the button and press the button to confirm Pi HS Hysteresis T Difference between the desired and current temperature If the hysteresis is 1 C and the desired temperature is 20 C the thermostat switches off at 20 C and on at 19 C see the graph For correct hysteresis function set the parameters according to the heating system type see CONST 5 Note If hysteresis is selected CONST 6 is skipped automatically l EG IL Ai De gt an PI proportional integral control The Pl control principle consists in comparison of the current room temperature with the desired temperature The Pl control aims at achieving and maintaining the desired temperature without overshooting See the graph For correct function of the Pl control set the control parameters according to the type of the heating system with respect to the room thermal inertia see CONST 6 Note If the Pl control is selected CONST 5 is skipped automatically PID proportional integral derivative control The PID control principle consists in continuous comparison of the current room temperature with the desired temperature and automatic adaptation of the controller to
6. 17 22 22 17 Tuesday 08 23 21 18 Wednesday 06 20 08 18 14 21 17 22 22 17 Wednesday 08 23 21 18 Thursday 06 20 08 18 14 21 17 22 22 17 Thursday 08 23 21 18 Friday 06 20 08 18 14 21 17 22 22 17 Friday 08 23 21 18 Saturday 07 21 17 23 22 19 Saturday 08 23 21 18 Sunday 07 21 17 23 22 19 Sunday 08 23 21 18 CONST CONSTANTS Setting the control parameters CONST Press twice the MENU button choose the CONST mode by turning the button and press the ot button to confirm 1 ENGLISH English language set by default Language selection CZ PL EN DE RU SVk CONST Choose the language by turning the button and press the button to confirm 2 MINIMUM CONTROL TEMPERATURE 5 C set by default LEESKT Setting the limit of the minimum temperature which can be set If using the GSM module you will be informed by an SMS that the room temperature has dropped below this value Choose within the range const from 3 C to 10 C by 0 5 C Set the value by turning the button and press the button to confirm ee a 3 MAXIMUM CONTROL TEMPERATURE 39 C set by default Setting the limit of the maximum temperature which can be set If using the GSM module you will be informed by an SMS that the room temperature has risen above this value Choose within the range from 15 C to 39 C by 0 5
7. THE ADO5 jack POWER SOURCE MUST BE USED see page 3 FIRST SWITCH ON After you switch on BPT322 GST first the following message appears on the LCD follow the instructions to make the corresponding settings INSERT SIM CARD BEFORE POWER CONNECTION Press the MENU button twice tf mi Z Anan choose the CLOCK mode by OS 4M 2 turning the q button and make ies 4 cI EuL ig 5 the settings acc to page 5 m ime m i lt a gt m im ry j S lt a wry mr rae e m pe af g GSM module is being checked Press the MENU button twice choose the CONST mode by turning the button move on to set CONST13 acc to page 9 CONST CONST OPERATING MODES AND TRANSMITTER SETTING Pressing any button first you activate the display backlit By another short press of the MENU button you open the main menu in which you can choose operating modes AUTO the Pr3 weekly program set by default see page 6 AUTO The thermostat works according to the weekly program settings this program can be changed for detailed description see PROG page 6 Press twice the MENU choose the AUTO mode by turning the and press the button to confirm 22 sss ss Sse M SMS form Auto TTT Change of the mode to AUTO Thermostat will be w
8. 22 18 Note program No 6 1 2 3 4 5 6 program No 7 1 2 3 4 5 6 5 21 meg Monday 07 21 09 18 15 22 18 23 22 18 Monday 07 22 09 18 15 23 18 24 22 18 All the bate Tuesday 07 21 09 18 15 22 18 23 22 18 Tuesday 07 22 09 18 15 23 18 24 22 18 indicated that the required Wednesday 07 21 09 18 15 22 18 23 22 18 Wednesday 07 22 09 18 15 23 18 24 22 18 programs temperature at 5 Thursday 07 21 09 18 15 22 18 23 22 18 Thursday 07 22 09 18 15 23 18 24 22 18 ean he o clock is 21 C Friday 07 21 09 18 15 22 18 23 22 18 Fricay 07 22 09 18 15 23 18 24 22 18 i Saturday 07 21 18 23 22 18 Saturday 08 22 18 24 22 18 changed Sunday 07 21 18 23 22 18 Sunday 08 22 18 24 22 18 Even or odd week selection This setting is suitable for example for shift operation the requirements on thermal comfort in the object CONST change every week The PrU and PrL programs will alternate automatically The programs can also be modi fied according to your requirements o Press twice the MENU button choose the CONST mode by turning the button and press the os JEg button to confirm Repeat pressing the button until the constant No 9 appears on the LCD Set YES by 9 idd EVEN ModE turning the button and press the button to confirm program U 1 2 3 4 5 6 program L 1 2 3 4 5 6 Monday 06 20 08 18 14 21 17 22 22 17 Monday 08 23 21 18 Tuesday 06 20 08 18 14 21
9. BOILER N L 230 V 50Hz CODE LEARNING The BPT322 GST assembly is configured and ready to use to put the receiver and transmitter in operation just use the TEST function see page 5 If the receiver memory has however been cleared the red diode is flashing proceed as follows 1 Press the receivers FUNCTION BUTTON for about 1 5 sec the yellow and red LEDs start flashing alternately and the receiver is awaiting the code learning mode 2 Press twice the MENU button on the receiver after connecting the power supply and activating see page 3 choose the TEST mode by turning the button and confirm it by pressing button The TEST RFM message is displayed by turning button start the test The sign for wireless transmitting appears shortly on the transmitter and once communication is established the RFM sing will lit permanently 3 The code receipt in the receiver is indicated by simultaneous flashing of the yellow and red LEDs thus the code has been learnt After the code receipt the output relay is switched several times to verify correct function of BPT322 GST Backlit display After you press any button the display is backlit automatically for at least 5 s E Sse 2 1848S 20912 6 7 89 AUTO MANU N QQ AO TRANSMITTER DESCRIPTION The GSM aerial is included in the packing can be replaced by an external one with higher sensitivity
10. confirm each setting with the or 20 VERSION restoring the default settings Firmware version informative parameter only If you press the button long for about 3 s the RESET message appears shortly on the LCD and the thermostat returns to the default settings USER TIPS QUICK CHANGE OF REQUIRED TEMPERATURE PROGRAM IN THE AUTO MODE Press twice the the required temperature starts flashing on the display Change the required tempera ture by turning the button and press the The change will last until the next program change eS sso sse sss M SMS form Temp xx where xx are only integers within the range of CONST2 and CONST3 Change of the desired temperature the change will last until the next temperature change given by the program Press thrice the setting programm starts flashing on the display Change it by turning button and press the QUICK CHANGE OF REQUIRED TEMPERATURE IN THE MANU MODE Press twice the the required temperature starts flashing on the display Change the required tempe rature by turning the button and press the The change will last until the next manual temperature change ee ess jac eso D SMS form Temp xx where xx are only integers within the range of CONST2 and CONSTS Change of the desired temperature the change will be permanent OPERATIONAL HOURS Push the button four tim
11. table You can cancel the code by setting CONST 16 to NO or by restoring the default settings of the thermostat See CONST 20 CONST CONST YOUR CODE in case of loss of the code it is necessary to bring the thermostat to factory settings using pressing buttons RESET see page 1 and MENU will erase all settings changes 18 BOILER INSPECTION REMINDER 1 1 2032 set by default Set the date on which you want to be informed about the necessity of the prescribed boiler service At the required time the MAINTENANCE NECESSARY message and the N symbol will appear on the bot tom line of the LCD you can cancel the message by setting a new date for the next boiler maintenance Gradually set the day month and year by turning the button confirm each setting with the O 19 PASSWORD not set by default It is used for locking the constants related to the given control settings Suitable for service technicians After a numerical code has been entered the user cannot change constants No 4 5 6 and 10 If you open the CONST mode and browse the constants the o symbol appears next to the constants locked if you turn the button the password is required Unless you enter the password the con stants remain locked To try to unlock them again you must exit the CONST mode and browse up the constant locked again Turning the button gradually enter four digits and
12. will be work acc last setting weekly program Man Setting MANU mode thermostat will be keep last setting temperature Heating system switched off permanently to cancel the function use the Temp xx message thermostat will automatically enter into the MANU mode with the given temperature or SMS message Auto for AUTO mode or Manu for MANU Temp xx Required temperature change only integer numbers can be entered they must fall within the permitted range of maximum and minimum temperatures CONST2 and CONST3 Back call xx temperature value in C always a two digit number e g 05 Any type of mobile phone can be used for sending and receiving back messages If you can set the font size format in your phone always use the MEDIUM size when writing messages if there are three options or the BIG size if there are two options FORMS OF BACK MESSAGES FROM THE THERMOSTAT Requir xx x Temperature required user se O O oo O Set off Heating system Off Thermostat in automatic AUTO mode Thermostat in manual MANU mode Thermostat in the OFF mode permanently off Signal strength at the place where the module is located where x is the value within the range of O to 5 O undeterminable or no signal detected 1 the worst strength 5 the best signal strength Sens 2 xx x__ Current temperature ofthe externalsensor O Z o Z xx X temperature value in C BACK MESSAGES ARE SENT WITHIN 3 MINUTES Note If
13. BPT322 GST WIRELESS ROOM THERMOSTAT WITH GSM MODULE A sophisticated wireless thermostat which can be remotely controlled by means of SMS messages from your mobile phone Wireless version enables easy and quick installation It is not necessary to install labour consuming lines between the thermostat and boiler that must come through floors The transmitter includes two devices temperature controller and GSM module which cooperate thus increasing the comfort of the heating system control Simple control elements are used for setting intuitive navigation in the selected language CZ PL EN DE RU SVK Remote control is executed by means of brief SMSs which enable you for example to change the required temperature or turn off the system The receiver is equipped with a code self learning system and the E EPROM memory which saves the code stored even in the event of voltage failure BPT322 GST works with two way communication at the frequency of 433 92 MHz The assembly may reach the range of up to 35 m in built up area This unique wireless thermostat with a big backlit display and intelligent PID control offers a wide variety of usage in residential houses offices as well as recreation areas receiver wall mounted aN e Receiver mains supply of 230 V 50 Hz e Receiver with the CODE SELF LEARNING system and 6 E EPROM memory saving the code even at voltage i l failure p BARI e Two wire connection to the boiler potential free FEL
14. L contact f i Indicator LED signalling the states mains supply indication transmission reception of signals failure state relay switched TWO WAY COMMUNICATION rA guarantees reliability of signal transmission and enables acquiring of return information transmitter A e Enable to change the required temperature or change the mode by means from mobile phone e Big well arranged and backlit display e Intuitive navigation in the selected language CZ PL EN DE RU SVK i e 9 weekly programs 4 e 6 temperature changes per every day e Programming by 10 minutes and 0 5 C e Programming by days or Mon Fri Sat Sun and Mon Sun m e Possibility of setting HYSTERESIS PI regulation or PID regulation S5 e Possibility of connectin an external temp sensor e Preliminary heating start function e Possibility of short term temperature change BPT32 GST e Even odd week selection ar see e Current temperature correction e Key lock GSM module integrated P Jaen neh A ore modern design e Permanent shutdown OFF stand for stable setting at the optimum e Holiday mode location e Summer mode e Anti freeze temperature 3 C e TEST function e Automatic SUMMER WINTER time change e Clock backup in case of power failure approx 7 days if ESE rechargeable batteries are used not included in the packing ELEKTROBOCK CZ MADE IN CZECH REPUBLIC 1 MENU Ese RECEIVER CONTROL ELEMENTS Indicating LED
15. TING Allows the following options CONST 1 TO SENdER SMS will be sent back to the telephone number from which the message was sent 2 TO ANOTHERNR SMS vill be sent back to the telephone number entered in the thermostat Aft 3 BOTH NUMbERS SMS will be sent back to both telephone numbers combination options 1 and 2 fib SEWER When choosing 2 and 3 option we enter a phone number n the international format 420123456789 LE to which return SMS messages on the thermostat condition should be sent Is possible to enter a phone TA number min 10 digit to 15 digit Turning the 4 button enter the phone number stepwise confirm each setting with the button 13 PIN CODE SETTING Enter the PIN code of the SIM card inserted in the thermostat CONST Turning the button enter 4 digits stepwise confirm each setting with the button 14 GSM TEST After setting the PIN code of the SIM card inserted in the thermostat is performed to test the GSM module and PIN validation CONST Turning the button to start test of GSM module and checking of PIN code LEGE The button displays the next constant pushing you return to the main menu 4 GGM TEGI CONST CONST CONST CONST Checking the PIN entered SIM card not inser Wrong PIN GSM module correctly ted Insert the SIM Reset BPT322 GST card
16. ation the requirements on thermal comfort in the object change every week Set YES NO by turning the button and press the button to confirm 10 HEATING COOLING SELECTION HEAT set by default Setting the thermostat function HEATING the output relay for heating systems switches if the current temperature drops below the desired value COOLING the output relay for cooling systems switches if the current temperature rises above the desired value Set HEAT COOL by turning the button and press the button to confirm 11 TEMPERATURE CORRECTION 0 C set by default This is used for correcting the temperature measured by the thermostat The setting can only be done after 12 hours of operation when the internal sensor temperature has settled Measure the room temperature with a thermometer if it is different from the temperature on the thermostat set the correction within the range of 5 C do 5 C Set the correction by turning the button and press the button to confirm CONST mos Ca a Oo a be I 2a N a vy gt Ve rm elas rie CONST ri CONST IT s a ma CONST Data gt gt az gt 5 rr gt az CONST I1 l CONST CONST CONST CONST CONST 12 EXTERNAL SENSOR SELECTION set by defau
17. disconnect and enter PIN again power to the 5s make adjustment and repeat test 15 RELAY TEST Testing the correct connection the thermostat to boiler this function is identical with the TEST mode in the main menu Start the test by turning the button The output relay is switched on off several times the ON OFF o messages appear on the LCD The button displays the next constant pushing Ce you return to CCIE the main menu 6 CONST 16 KEY LOCK NO set by default This is used for locking the controls as a protection against undesirable interference of a foreign person Set YES NO by turning the button and press the button to confirm 17 KEY CODE This constant can be set if CONST 16 YES It is used for setting the code by which you will be able to activate the controls Set a four digit combination range from O to 9 The keys will be locked within 1 minute after opening the basic display The symbol appears on the LCD If you press the or button the LCD asks you to enter the key code after entering the correct code you are able to make any changes the controls are functional again The controls will automatically be locked again after you finish the setting within approx 1 min Gradually set 4 digits by turning the button confirm each setting with the button RECOMMENDATION Record the key code in the
18. es The boiler operating hours appear on the LCD The figure on the picture means 906 hours 43 minutes Resetting the counter When operational hours are displayed turn the button anti clockwise EXTERNAL SENSOR TEMPERATURE Push the button five times The current temperature of the external sensor appears on the LCD the value is only informative and appears only if the external sensor is monitoring the maximum floor temperature see CONST 12 page 9 CONST N Da ln iar Daa Ll a lis TI mr Z D M CONST itt CONST AUTO MANU om IU INFORMATION IN THE LCD DYNAMIC LINE SIGNAL GSM x Determines the signal strength at the place where the thermostat is located where x is a value within the range from O to 5 O undeterminable or no signal detected 1 worst level 5 best level of signal REQUIR TEMP Information on the desired temperature preset PROGR 3 PERIOd 2 Information on the program preset e g 3 and the time interval running interval 2 thermostat restores the last selected AUTO MANU mode connected EXT SENS STOP If the preset limit temperature of the external sensor in the maximum floor temperature monitoring function is exceeded see page 7 the thermostat is switched off FORMS OF MESSAGES SENT Info Information on the heating system status Auto Setting AUTO mode thermostat
19. itter within one hour It is necessary to set only time all other settings remain saved in memory if there are not rechargeable batteries in the transmitter RED LED LIT ON RECEIVER FAILURE The thermostat is in failure mode 2 minutes ON and 8 minutes OFF 1 Check the transmitter power supply control 2 Test the thermostat for correct connection by using TEST mode see page 5 If the connection between transmitter and receiver is not established please contact the service department under www elbock cz THE THERMOSTAT DOES NOT RESPOND TO SMS COMMANDS 1 Check the transmitter bower supply control 2 Check if the SIM card is activated If the connection between transmitter and receiver is not established please contact the service department under www elbock cz TECHNICAL PARAMETERS Transmitter Power suppl oe ie ae typ ADOS Jack External sensor 230 V 50 Hz Communication type GSM module SIM 900 not included in the 433 92 MHz Aerial direct 1dB packing type CTO4 10k 300 m free area CYXY 2x05 Range i 433 92 MHz a 2 35 m built up area 10 kQ lenght 3 m N lt 102 dBm 0 1 to 6 C blastic case PVC i Adjustable temp range 5 C to 39 C CTO1 10k and IP20 Temperature setting CTO2 10k sensors can ST Working temp 0 C TO 40 C oe also be used p IP20 Working temperature 0 C to 40 C Dimensions transmitter Dimensions receiver Power source
20. lt If an external sensor is connected the symbol appears on the LCD to approx 2 minutes CONST The external sensor can be used for 1 control according to the room temperature the sensor is located in the room option ee 2 control according to the floor temperature the sensor is located in the floor option EEX GENSHP If connected the external sensor measures the temperature at the place of its installation suitable for example for places at which the thermostat cannot be located yet you want to control according to this room ne 3 maximum floor temperature monitoring the sensor is located in the floor selection of 15 to 99 5 C 15 99 5 C If connected the external sensor monitors the floor temperature the maximum a temperature allowed for floor heating must be set control according to the room EXT SENSOR temperature with simultaneous floor temperature monitoring If the preset limit temperature is exceeded the thermostat is switched off irrespective of the room ROTO temperature and the EXT SENS STOP message appears on the LCD The heating device is switched on again if the external sensor temperature drops by 0 5 C If the external sensor is unconnected or faulty the EXT SENS ERROR message appears on the LCD gt LU Set the external sensor option by turning the button and press the button to confirm tEL nO PHONE NUMBER SET
21. o the SIM card holder at the back of the control part see page 3 If you want to back up the time install the fully charged rechargeable batteries See Fig 2 Mount the control part onto the bottom cover Connect the power supply to the connector No 1 or No 2 see page 3 ATTENTION BPT322 GST MUST BE POWERED FROM ONE SOURCE The transmitter is freely portable and can be located for instance on the table We recommend you to use the delivered table stand installation acc to Fig 3 If installed on the wall no power lines must run around the thermostat Test the wireless communication between the transmitter and the receiver page 5 TEST Upon the first start or reset the thermostat shows the SET CLOCK ENTER PIN messages set the current time and date acc to the instructions on page 5 enter the PIN acc to page 9 and select language acc page 7 Fig 1 Fig 2 a e ees 08 OS A S wy A AA recharge AA recharge able battery F able battery Fig 3 The thermostat enables backup of time in case of power failure You must use rechargeable batteries 2x1 2 V type AA R6 After power failure the time remains cur rent approximate service life 2 years according to the type of batteries used The advantage is recharging of the batteries after the power supply is restored CAUTION THE BATTERIES ARE NOT USED FOR SUPPLYING THE THERMOSTAT FOR WHICH
22. ork acc last setting weekly program MANU default temperature setting of 21 C The thermostat works according to the temperature setting until the next manual change MANU Press twice the MENU choose the MANU mode by turning the and press the button to confirm D SMS form Manu i Change of the mode to MANU Thermostat will be keep last setting temperature MANG M HE OFF the anti freeze temperature of 3 C is kept cannot be changed The thermostat is permanently switched off until the next manual change of the mode OFF Press twice the MENU choose the OFF mode by turning the and press the button to confirm z 7 al SMS form Off a E Change of the mode to OFF You can cancel the mode by the SMS Temp xx or Auto or Manu MEE MHE HOLIDAY The thermostat maintains the preset temperature until the preset date and selected time After expiry of the AUTO NANU preset period it automatically returns to the AUTO MANU mode last selected before the holiday Press twice the MENU button choose the h mode by turning the and press the button to confirm Step by step set the temperature which the thermostat should keep during the holiday date and time of your return from the holiday Change the values by turning the button and confirm each change by pressing the button After making the settings press
23. rechargeable batteries of the AA R6 type not included in the packing LCD DESCRIPTION 10 11 12 13 i 2 14 A 15 16 5 17 6 7 8 18 i 19 20 Current day in the Prog mode selection of days to be programmed Heating on indication Current room temperature Clock setting mode Modes for setting programs PROG and constants CONST page 5 Automatic mode page 5 Manual mode page 5 Holiday mode page 5 Permanent shut off page 5 10 Summer mode page 8 11 Boiler inspection indication page 10 Type CT04 10k silicone conductor leng th 3 m for measurements 7 D A up to 99 C including S connector Use the type 5V OV 5V DC 2 5A SELV MIND THE POLARITY 12 Signal transmission indication 13 Signal transmission ERROR 14 External sensor connection indication see page 9 15 Wireless mode indication 16 Key lock indication page 10 17 Current time 18 Current date required temperature 19 Status line dynamically changing according to the process running 20 Low battery indication TRANSMITTER INSTALLATION The transmitter must be installed as far from interference sources TV PC etc as possible it must not be placed on a metal base Pay attention to the thermal characteristics of the given place at installation 1 2 3 4 5 6 T 8 9 Remove the control part from the bottom cover of the device Fig 1 Insert the activated SIM card int
24. ry to apply all six changes to one day Tables of temperature programs program No 1 program No 2 PROG Monday Tuesday Wednesday Thursday Friday Saturday Sunday program No 3 1 2 3 4 5 6 program No 4 1 2 3 4 5 6 program No 5 1 2 3 4 5 6 Monday 05 21 06 18 12 20 16 21 18 22 21 18 Monday 06 21 07 18 15 21 18 22 22 18 Monday 08 21 09 18 15 21 18 22 23 18 Tuesday 05 21 06 18 12 20 16 21 18 22 21 18 Tuesday 06 21 07 18 15 21 18 22 22 18 Tuesday 08 21 09 18 15 21 18 22 23 18 Wednesday 05 21 06 18 12 20 16 21 18 22 21 18 Wednesday 06 21 07 18 15 21 18 22 22 18 Wednesday 08 21 09 18 15 21 18 22 23 18 Thursday 05 21 06 18 12 20 16 21 18 22 21 18 Thursday 06 21 07 18 15 21 18 22 22 18 Thursday 08 21 09 18 15 21 18 22 23 18 Friday 05 21 06 18 12 20 16 21 18 22 21 18 Friday 06 21 07 18 15 21 18 22 22 18 Friday 08 21 09 18 15 21 18 22 23 18 Saturday 07 21 21 18 Saturday 07 21 18 22 22 18 Saturday 08 21 18 22 22 18 Sunday 07 21 21 18 Sunday 07 22 18 23 22 19 Sunday 08 21 18 22
25. s GREEN LIT UP electrical power connection on PWR rit i 7 BLUE SHORT BLINKING sending or receiving a signal ERROR I l RED BLINKING empty E EPROM memory RED LIT UP FAILURE Error mode if no signal is received from the transmitter in 6 hours will switch to a2 min ON and 8 min OFF sequence BLUE RED BLINKING ALTERNATELY code learning mode BLUE RED BLINKING CONCURRENTLY code accepted BLUE RED LIT TOGETHER memory erase mode ORANGE LIT UP relay is switched on Front cover lift of Holes for installation on KU KP68 Fig 1 Fig 2 FUNCTION BUTTON SHORT PRESS for approx 1 s output terminals t CODE LEARNING mode for boiler F LONG PRESS for apprrox 3s potential free RESET memory clearing switching RECEIVER INSTALLATION lift off the front cover see Figs 1 2 attach the receiver to the wall or to an installation box turn off main switch connect the receiver acc to the diagram use terminals for room thermostat 2 wires connect the receiver to the 230 V 50 Hz power supply switch on the power The green LED will light up and the receiver is ready for activation Install the receiver in internal rooms as far from big metal objects as possible at least 0 5 m and far from power lines owing to interference of the signal received It is recommended that the device is installed by a person with adequate qualification in electrical engineering Wiring diagram
26. the button Tee ee ee Minimum source g typ switch on time Electric heating Plate radiators 2 3 Cast iron radiators Oo 4 7 PRELIMINARY SWITCH ON OF HEATING NO set by default This function guarantees you the required temperature at the required time You need not consider when to switch the heating on in order to be warm when getting up in the morning without heating unnecessarily long in advance You just program the time at which you want the desired temperature Within two opera ting days the program ascertains the thermal constants of the room and then it switches the heating on In advance sufficiently The preliminary switch on time is limited to 2 hours Set YES NO by turning the button and press the button to confirm 8 SUMMER MODE NO set by default In this mode you are not allowed to switch the heating on It can particularly be used in the summer period when you need not heat After you enable this mode the ey symbol appears on the display Note The anti freeze protection 3 C is still enabled In this mode you cannot change the temperature or set the holiday mode Set YES NO by turning the button and press the button to confirm 9 EVEN ODD WEEK SELECTION NO set by default If you choose YES the PrU and PrL programs will alternate automatically according to the current week even odd This setting is suitable for example for shift oper
27. the button to return to the basic screen TE Note The holiday mode can be cancelled any time by selecting another AUTO or MANU mode 4 CLOCK SETTING Setting the current time and date Press twice the MENU button choose the CLOCK mode by turning the button and press the O button to confirm Change the values by turning the button and confirm each change by pressing the button the CET T IMP parameter modified is always flashing pressing the button you return to the menu PROG PROGRAMMING GET HOUR You can set 9 weekly programs with 6 temperature changes per day The Pr1 and Pr2 programs are empty Pr3 to Pr7 programs are set by default The PrU and PrL are also set by default intended for the EVEN ODD week option for details see pages 6 and 8 CONST CONSTANTS Mh i Setting the control parameters For a detailed description see page 7 ae Press twice the MENU button choose the CONST mode by turning the button and press the button to confirm TEST Testing the correct connection to boiler Press twice the MENU choose the TEST mode by turning the button and press the button to confirm RELAY TEST is showed on LCD Turn the button to start testing The output relay will be switched on off several times the ON OFF messages appear on the LCD
28. the given conditions This is the most perfect continuous control you can achieve not only short control time but also high accuracy without permanent con trol deviation The minimum switch on time is internally set to 2 minutes the proportional band is 2 C the time interval is automatically recalculated according to current temperature conditions Note If the PID control is selected CONST 5 and CONST 6 are skipped automatically HYSTERESIS PI CONTROL PID CONTROL proportional Heating ON Note The graphs are just tentative the real control course differs according to current conditions in the measured object CAUTION ONLY IN CASE OF LOCKING BY PASSWORD see CONST19 Ifthe O key symbol appears on the LCD the constant selected cannot be modified and you must know the PASSWORD see CONST 19 page 8 You can change the constant after entering the password After you exit the CONST mode the security lock of the constants related to the control will be activated automatically CONST 5 SETTING HYSTERESIS PARAMETERS HYSTERESIS factory setting of 0 5 C Set from 0 1 to 6 C According to the value preset the thermostat switches on at the temperature T switching T required HYSTERESIS Set the hysteresis by turning the button and confirm with the button
29. the minimum maximum room temperature preset CONST 2 and 3 is exceeded the WARNING SMS is automatically sent in a form similar to that in the Info form Info If using a credit card you must make a paid call once in 3 months This call is executed automatically in 80 days between 4 and 9 PM to the phone number entered in the thermostat CONST tEL nO after 20 s the call is terminated automatically You can execute this function earlier by means of the Call SMS message PRACTICAL EXAMPLES OF USING USING AND SETTING OF BPT322 GST The thermostat is located in a room where anti freeze temperature must be maintained e g 7 C 1 Connect the BPT322 GST strictly according to the instructions 2 Choose the MANU mode 3 Press the button and set the temperature of 7 C by turning the A button 4 Before arriving at the object write an SMS in your mobile with the wording Temp 23 then send the SMS to the number of the SIM card inserted in your thermostat After receiving the message the thermostat automatically switches on the heating system until the desired temperature is reached Then BPT322 GST automatically sends the BACK SMS message informing you about the temperature change made After arriving at the object you can change the temperature according to your needs on the thermostat directly VOLTAGE FAILURE By short voltage failure on receiver comes to connection establishment with transm