Home

Sun Ultra 80 SCSI Cable Installation Guide

image

Contents

1. e JE E T 7 o o ma tose TA g ral fc J eae g 7 2 a Props Undo Tebe 9 w R T i i J g D gt D POET FIGURE 2 5 Type 6 Keyboard Chapter 2 CODE Powering On Off and Internal Access 2 7 2 8 Sun Ultra 80 SCSI Cable Installation Guide March 2000 CHAPTER 3 Removing and Replacing the Peripheral Assembly To remove and replace a peripheral assembly drive it is necessary to remove and replace the peripheral assembly Note A peripheral assembly drive can be a CD ROM drive a 4 mm tape drive an 8 mm tape drive or any offered optional drive component such as a PCI connected device 3 1 Removing the Peripheral Assembly Remove any CD ROM tape or diskette in the drive Power off the system and remove the access panel See Section 2 1 Powering Off the System Removing the Access Panel on page 2 1 Caution Use proper ESD grounding
2. 80 SCSI Cable Installation Guide March 2000 3 Detach the antistatic wrist strap 4 Replace the access panel and power on the system See Section 2 3 Replacing the Access Panel Powering On the System on page 2 6 Chapter 3 Removing and Replacing the Peripheral Assembly 3 5 3 6 Sun Ultra 80 SCSI Cable Installation Guide March 2000 CHAPTER 4 Installing the Optional SCSI Cable Component 1 Remove the peripheral assembly and install the second SCSI device See Chapter 2 Powering On Off and Internal Access and Chapter 3 Removing and Replacing the Peripheral Assembly for safe procedures 2 Before installing the optional SCSI cable component slide the peripheral assembly partially out of the chassis for easier access 3 Install the optional SCSI cable as follows FIGURE 4 1 and FIGURE 4 2 a g If the SCSI device is already cabled disconnect the old SCSI cable from the SCSI terminator board and from the existing SCSI device Remove the old SCSI cable from the system Connect the male end of the optional SCSI cable connector to the female end of the SCSI terminator board Install the SCSI cable onto the cable management hooks part of chassis Connect the middle connector of the new SCSI cable onto the rear connector of the peripheral assembly topmost SCSI device Connect the end connector of the new SCSI cable onto the rear connector of the other SCSI device The Sun Ultra
3. utilisation visuelle ou graphique pour l industrie de l informatique Sun d tient une licence non exclusive de Xerox sur l interface d utilisation graphique Xerox cette licence couvrant galement les licenci s de Sun qui mettent en place l interface d utilisation graphique OPEN LOOK et qui en outre se conforment aux licences crites de Sun CETTE PUBLICATION EST FOURNIE EN L ETAT ET AUCUNE GARANTIE EXPRESSE OU IMPLICITE N EST ACCORDEE Y COMPRIS DES GARANTIES CONCERNANT LA VALEUR MARCHANDE L APTITUDE DE LA PUBLICATION A REPONDRE A UNE UTILISATION PARTICULIERE OU LE FAIT QU ELLE NE SOIT PAS CONTREFAISANTE DE PRODUIT DE TIERS CE DENI DE GARANTIE NE S APPLIQUERAIT PAS DANS LA MESURE OU IL SERAIT TENU JURIDIQUEMENT NUL ET NON AVENU GS Mu T Adobe PostScript Preface The Sun Utra 80 SCSI Cable Installation Guide describes how to install the Sun Ultra 80 SCSI cable optional component Related Documentation Application Title Part Number Service Sun Ultra 80 Service Manual 805 6618 Accessing Sun Documentation Online The docs sun com web site enables you to access Sun technical documentation on the Web You can browse the docs sun com archive or search for a specific book title or subject at http docs sun com Ordering Sun Documentation Fatbrain com an Internet professional bookstore stocks select product documentation from Sun Microsystems Inc For a list of documents and how to or
4. 80 will support only two SCSI devices in the peripheral assembly Connect the power cables to the rear connector of both SCSI devices 4 Slide the peripheral assembly back into the system chassis 4 1 SCSI terminator Optional SCSI board cable component SCSI cable middle connector SCSI cable end connector FIGURE 4 1 Installing the Optional SCSI Cable Component 4 2 Sun Ultra 80 SCSI Cable Installation Guide March 2000 FIGURE 4 2 Reinstalling the Power Cables Chapter 4 Installing the Optional SCSI Cable Component 4 3 4 4 Sun Ultra 80 SCSI Cable Installation Guide March 2000
5. ates the system power interlock circuit This safety mechanism prevents all DC voltages except 5 VDC standby power from reaching any internal components when the access panel is removed ion t ice posi a Lay the system in the serv b Press down on the two depressions at the top of the access panel Tilt the top of the access panel out about an inch c Lift the access panel up and clear of the chassis 2 3 Powering On Off and Internal Access Chapter 2 ing the Access Panel FIGURE 2 3 Removing Replac 2 4 Sun Ultra 80 SCSI Cable Installation Guide March 2000 2 2 Attaching the Antistatic Wrist Strap Caution Wear an antistatic wrist strap and use an ESD protected mat when handling components When servicing or removing system components attach an ESD strap to your wrist then to a metal area on the chassis and then disconnect the power cord from the system and the wall receptacle Following this caution egualizes all electrical potentials with the system Disconnect the power cord Attach the antistatic wrist strap as follows FIGURE 2 4 a Unwrap the first two folds of the antistatic wrist strap and wrap the adhesive side firmly against your wrist b Peel the liner from the copper foil at the opposite end of the antistatic wrist strap c Attach the copper end of the antistatic wrist strap to the chassis Chapter 2 Powering On Off and Internal Access 2 5 Antistatic wri
6. der them visit the Sun Documentation Center on Fatbrain com at http wwwl fatbrain com documentation sun Sun Welcomes Your Comments Sun is interested in improving its documentation and welcomes your comments and suggestions You can email your comments to Sun at docfeedback sun com Please include the part number of your document in the subject line of your email iv Sun Ultra 80 SCSI Cable Installation Guide March 2000 Contents Preface iii Optional SCSI Cable Component 1 1 1 1 Optional SCSI Cable Component Kit 1 2 1 2 System Hardware Requirements 1 2 13 SCD Compliance 1 2 14 How to Proceed 1 3 Powering On Off and Internal Access 2 1 2 1 Powering Off the System Removing the Access Panel 2 1 2 2 Attaching the Antistatic Wrist Strap 2 5 2 3 Replacing the Access Panel Powering On the System 2 6 Removing and Replacing the Peripheral Assembly 3 1 3 1 Removing the Peripheral Assembly 3 1 3 2 Installing an Optional Component 3 3 3 3 Replacing the Peripheral Assembly 3 4 Installing the Optional SCSI Cable Component 4 1 Contents v vi Sun Ultra 80 SCSI Cable Installation Guide March 2000 CHAPTER 1 Optional SCSI Cable Component The Sun Ultra 80 system supports up to two SCSI devices with 50 pin SCSI connectors in its peripheral assembly removable media drive bay This book explains how to install the optional SCSI cable component when a second SCSI removable media drive is added to the sys
7. es Products bearing SPARC trademarks are based upon an architecture developed by Sun Microsystems Inc The OPEN LOOK and Sun Graphical User Interface was developed by Sun Microsystems Inc for its users and licensees Sun acknowledges the pioneering efforts of Xerox in researching and developing the concept of visual or graphical user interfaces for the computer industry Sun holds a non exclusive license from Xerox to the Xerox Graphical User Interface which license also covers Sun s licensees who implement OPEN LOOK GUIs and otherwise comply with Sun s written license agreements RESTRICTED RIGHTS Use duplication or disclosure by the U S Government is subject to restrictions of FAR 52 227 14 g 2 6 87 and FAR 52 227 19 6 87 or DFAR 252 227 7015 b 6 95 and DFAR 227 7202 3 a DOCUMENTATION IS PROVIDED AS IS AND ALL EXPRESS OR IMPLIED CONDITIONS REPRESENTATIONS AND WARRANTIES INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE OR NON INFRINGEMENT ARE DISCLAIMED EXCEPT TO THE EXTENT THAT SUCH DISCLAIMERS ARE HELD TO BE LEGALLY INVALID Copyright 2000 Sun Microsystems Inc 901 San Antonio Road Palo Alto CA 94303 4900 Etats Unis Tous droits r serv s Ce produit ou document est prot g par un copyright et distribu avec des licences qui en restreignent l utilisation la copie la distribution et la d compilation Aucune partie de ce produit ou document ne peut tre reproduite so
8. he power cord prior to servicing system components 5 Turn off the power to the monitor 6 Disconnect cables to any peripheral equipment 7 Remove the lock block if installed FIGURE 2 2 Power switch FIGURE 2 1 System Power 2 2 Sun Ultra 80 SCSI Cable Installation Guide March 2000 E gt ay O lt x o 5 2 3 x x 9 o J ccc Oc ZISIZO IIRIS o FIR RAZZI lo leto te te teo LISI IRA QRORQROROROKORO GR RSS POLO SERELEROLEROLSRO lol S amp m Vo o we o 9099909099990 gt 980808080808000 08080808080808080808080 080809080008080 080808000800080 GRGBORORGLGLGLLOLSLGLG 200802020808 000 020200080800 020000 000808000800080 020200000808 QBQBOSOESSQ8O86 ADN 280800020808000 200000000000009 _ SEORORORORORORORORORORS 980099000099009 080808080808080 220808080808080 9939300995999 soznzozozazazaza zzz za 909020900990909 QROLOLSEGLOLORO SISIZIZZZIZIZIZIZZZIZIZ OROSOLGLOLOLGLS QBQSOSOESSQSOSO QBOBOROROREROBORSRORSBO sGEOROLQBOSOESLS 20208080200020 BOLSESSOR0R0R5252520208 808020202020209 OSO 0806080000 580008000008090 0000000 888 aBoZogogososogo Meseia ee OG Sei c9a999909090900090000 o e FIGURE 2 2 Lock Block Location 8 Remove the access panel as follows FIGURE 2 3 Note Removing the access panel activ
9. si amp Sun microsystems Sun Ultra 80 SCSI Cable Installation Guide Sun Microsystems Inc 901 San Antonio Road Palo Alto CA 94303 U S A 650 960 1300 Part No 806 4423 10 March 2000 Revision A Send comments about this document to docfeedback sun com Copyright 2000 Sun Microsystems Inc 901 San Antonio Road Palo Alto CA 94303 4900 USA All rights reserved This product or document is protected by copyright and distributed under licenses restricting its use copying distribution and decompilation No part of this product or document may be reproduced in any form by any means without prior written authorization of Sun and its licensors if any Third party software including font technology is copyrighted and licensed from Sun suppliers Parts of the product may be derived from Berkeley BSD systems licensed from the University of California UNIX is a registered trademark in the U S and other countries exclusively licensed through X Open Company Ltd For Netscape Communicator the following notice applies Copyright 1995 Netscape Communications Corporation All rights reserved Sun Sun Microsystems the Sun logo AnswerBook2 docs sun com Ultra and Solaris are trademarks registered trademarks or service marks of Sun Microsystems Inc in the U S and other countries All SPARC trademarks are used under license and are trademarks or registered trademarks of SPARC International Inc in the U S and other countri
10. st strap FIGURE 2 4 Attaching the Antistatic Wrist Strap to the Chassis 2 3 Replacing the Access Panel Powering On the System Replace the access panel and power on the system as follows FIGURE 2 3 Caution If the access panel is installed incorrectly the power interlock circuit will remain activated Ensure that the access panel is installed correctly 1 Hold the access panel centering it over the chassis opening 2 Lower the access panel lightly onto the chassis until the access panel hooks engage the chassis rail 2 6 Sun Ultra 80 SCSI Cable Installation Guide March 2000 a Tilt the top of the access panel in toward the chassis until it clicks into place Verify that the access panel clicks into both sides of the chassis top Replace the lock block FIGURE 2 2 Place the system into the operating position Turn on power to all connected peripherals Note Peripheral power is activated prior to system power so the system can recognize the peripherals when it is activated Connect the power cord to the wall and the system Momentarily press the power switch FIGURE 2 1 or the Type 6 keyboard power key FIGURE 2 5 Verify the following a The front panel LED is on b The system fans are spinning Power key Ee E E F3 J E JE ral ea AE
11. techniques when handling components Wear an antistatic wrist strap and use an ESD protected mat Store ESD sensitive components in antistatic bags before placing them on any surface Attach the antistatic wrist strap See Section 2 2 Attaching the Antistatic Wrist Strap on page 2 5 Remove the peripheral assembly as follows FIGURE 3 1 and FIGURE 3 2 a Remove the peripheral bezel assembly by pressing down on the top of the bezel and pulling it straight out from the chassis b Using a No 2 Phillips screwdriver remove the four screws securing the peripheral assembly to the chassis c Partially remove the peripheral assembly from the chassis d Disconnect the power and interface cables from all drives installed in the peripheral assembly e Remove the peripheral assembly from the chassis 5 Place the peripheral assembly on an antistatic mat FIGURE 3 1 Removing and Replacing the Peripheral Assembly 3 2 Sun Ultra 80 SCSI Cable Installation Guide March 2000 DR Installing an Optional Component Note Ensure that the peripheral power cable and all data cables are properly routed through the clips adjacent to the peripheral assembly Route the SCSI data cable through the cable management hooks part of chassis adjacent to the hard drive cage Caution Use proper ESD grounding techniques when handling components Wear an antistatic wrist strap and use an ESD protected mat Store ESD sensiti
12. tem For more detail on the Sun Ultra 80 system please consult the Sun Ultra 80 Service Manual part number 805 6618 Peripheral assembly removable media drive bay FIGURE 1 1 Ultra 80 Workstation 1 1 1 1 Optional SCSI Cable Component Kit Each optional SCSI cable component kit contains m This book m SCSI cable m Antistatic wrist strap 1 2 System Hardware Requirements System hardware requirements include a second SCSI device with a 50 pin connector to be installed in the peripheral assembly removable media drive bay The device may be a 4 mm tape drive an 8 mm tape drive or a second CD ROM drive 1 3 SCD Compliance Sun Ultra 80 systems have been independently tested and verified to comply with revision 2 1 of the SPARC Compliance Definition SCD developed by SPARC International Inc These systems are binary compatible with all other systems and software that conform to SCD version 2 1 1 2 Sun Ultra 80 SCSI Cable Installation Guide March 2000 1 4 How to Proceed If you are an experienced technician system administrator authorized service provider ASP or advanced computer system end user who has experience troubleshooting and replacing hardware you may want to start with Chapter 4 Installing the Optional SCSI Cable Component Otherwise first read and perform the procedures in sequence in Chapter 2 Powering On Off and Internal Access and Chap
13. ter 3 Removing and Replacing the Peripheral Assembly Chapter 1 Optional SCSI Cable Component 1 3 1 4 Sun Ultra 80 SCSI Cable Installation Guide March 2000 CHAPTER 2 Powering On Off and Internal Access This chapter contains procedures to power on and off the system and instructions on how to access the system for service m Section 2 1 Powering Off the System Removing the Access Panel on page 2 1 m Section 2 2 Attaching the Antistatic Wrist Strap on page 2 5 m Section 2 3 Replacing the Access Panel Powering On the System on page 2 6 21 Powering Off the System Removing the Access Panel To power off the system and remove the access panel Caution Prior to turning off the system power exit from the operating system Failure to do so may result in data loss 1 Back up system files and data 2 Halt the system trickle voltage remains in the power supply To remove all power from the system i Caution Pressing the power switch does not remove all power from the system a disconnect the power cord 3 Momentarily press the front panel power switch FIGURE 2 1 and follow the instructions on the screen Note If the system will not shut down such as when the operating system has crashed press and hold the power switch for at least five seconds 4 Verify the following a The front panel LED is off b The system fans are not spinning 1 Caution Disconnect t
14. us aucune forme par quelque moyen que ce soit sans l autorisation pr alable et crite de Sun et de ses bailleurs de licence s il y en a Le logiciel d tenu par des tiers et gui comprend la technologie relative aux polices de caract res est prot g par un copyright et licenci par des fournisseurs de Sun Des parties de ce produit pourront tre d riv es des syst mes Berkeley BSD licenci s par l Universit de Californie UNIX est une marque d pos e aux Etats Unis et dans d autres pays et licenci e exclusivement par X Open Company Ltd La notice suivante est applicable a Netscape Communicator Copyright 1995 Netscape Communications Corporation Tous droits r serv s Sun Sun Microsystems the Sun logo AnswerBook2 docs sun com Ultra et Solaris sont des marques de fabrique ou des marques d pos es ou marques de service de Sun Microsystems Inc aux Etats Unis et dans d autres pays Toutes les marques SPARC sont utilis es sous licence et sont des marques de fabrique ou des marques d pos es de SPARC International Inc aux Etats Unis et dans d autres pays Les produits portant les marques SPARC sont bas s sur une architecture d velopp e par Sun Microsystems Inc L interface d utilisation graphique OPEN LOOK et Sun a t d velopp e par Sun Microsystems Inc pour ses utilisateurs et licenci s Sun reconna t les efforts de pionniers de Xerox pour la recherche et le d veloppement du concept des interfaces d
15. ve components in antistatic bags before placing them on any surface Remove the filler panel if necessary FIGURE 3 2 Position the optional component into the middle shelf of the peripheral assembly Using a No 2 Phillips screwdriver tighten the four screws securing the optional component to the peripheral assembly Replace the peripheral assembly See Section 3 3 Replacing the Peripheral Assembly on page 3 4 Chapter 3 Removing and Replacing the Peripheral Assembly 3 3 IN Filler panel CD ROM drive location SL A EN Optional o gt Z component ZZ P Filler panel Diskette drive FIGURE 3 2 Installing Any Optional Tape Drive Component 3 3 Replacing the Peripheral Assembly an antistatic wrist strap and use an ESD protected mat Store ESD sensitive 1 Caution Use proper ESD grounding techniques when handling components Wear components in antistatic bags before placing them on any surface 1 Replace the peripheral assembly as follows FIGURE 3 2 a Position the peripheral assembly into the chassis b Connect the rear cable connectors as required c If an optional drive component is being installed undress the optional drive component power harness and route it from the CPU area into the peripheral area d Using a No 2 Phillips screwdriver tighten the captive screws securing the peripheral assembly to the chassis 2 Replace the peripheral bezel assembly 3 4 Sun Ultra