Home
TBS1000 Series Oscilloscopes Datasheet
Contents
1. Normal Moise Reject CHI SS lt 10Hz CHI 200m See all the details other oscilloscopes might miss with Tektronix proprietary digital real time sampling Performance You Need at a Price You Can Afford The TBS1000 Digital Storage Oscilloscope Series provides you with affordable performance in a compact design Packed with standard features including USB connectivity 16 automated measurements limit testing data logging and context sensitive help the TBS1000 Series oscilloscopes help you get more done in less time Digital Precision for Accurate Measurements With up to 150 MHz bandwidth and 1 GS s maximum sample rate no other digital storage oscilloscope offers as much bandwidth and sample rate for the price Tektronix proprietary sampling technology provides real time sampling with the stated sampling rate on all channels all the time to 2 www tektronix com Acq Complete Pos 12 50MHz MATH ett RA TT Poteet eet eee tenes FFT CHI Hanning a CHI 100dB 250MHz CS0 0MSs Hanning arh drah Quickly perform an FFT with the advanced math functions accurately capture your signals Sampling performance is not reduced when using multiple channels The TBS1000 Digital Oscilloscope Series is especially well suited to meet the needs of today s schools and universities Packed with features and built in tools the TBS1000 is easy to learn and simple to operate ideal for first time oscilloscope use
2. 0000025 00 1 02 22 0000025 00 1 02 23 0000025 00 1 02 24 00000249 02 1 02 25 00000249 04 1 00 Refresh Bee 126 00000249 06 1 00 27 00000249 10 98 Sat Dopey He ENNE PEN 28 00000249 06 1 00 coum ag gt 29 00000248 08 1 02 Place Graph In 30 00000248 10 1 02 Row 31 00000248 14 1 00 lt Ll Active Sheet 32 00000248 12 1 02 Al C New Sheet 33 00000248 16 1 00 34 00000247 16 1 00 35 00000247 16 1 02 i nen oa Y N Sheet1 Sheet Sheet3 m DEA Easily capture save and analyze measurement results with OpenChoice PC Communications Software Characteristics TBS1000 Series Digital Storage Oscilloscopes TBS1022 TBS1042 Digital Storage Oscilloscopes TBS1000 Series Display QVGA LCD Bandwidth 25 MHz 40 MHz Channels External Trigger Input Included on all models Sample Rate on Each 500 MS s 500 MS s Channel Record Length TBS1062 TBS1102 TBS1152 IPT 60 MHz 100 MHz 150 MHz 2 1 0 GS s 1 0 GS s 1 0 GS s 2 5k points at all time bases on all models Vertical Resolution Vertical Sensitivity 8 bits 2 mV to 5 V div on all models with calibrated fine adjustment DC Vertical Accuracy Vertical Zoom 3 on all models Vertically expand or compress a live or stopped waveform 300 Vrus CAT Il derated at 20 dB decade above 100 kHz to 13 Vp p AC at 3 MHz Maximum Input Voltage Position Range 2 mV to 200 mV div 1 8 V gt 200 mV to 5
3. Digital Storage Oscilloscopes TBS1000 Series Datasheet Tektronix TBS 1152 Sera storie oscaroscore NAMEN Features amp Benefits Key Performance Specifications 150 MHz 100 MHz 60 MHz 40 MHz and 25 MHz Bandwidth Models 2 channel Models Upto 1 GS s Sample Rate on All Channels 2 5k point Record Length on All Channels Advanced Triggers including Pulse Width Trigger and Line selectable Video Trigger Ease of Use Features 16 Automated Measurements and FFT Analysis for Simplified Waveform Analysis Built in Waveform Limit Testing Automated Extended Data Logging Feature Autoset and Signal Auto ranging Built in Context sensitive Help Probe Check Wizard Multiple language User Interface 5 7 in 144 mm Active TFT Color Display Small Footprint and Lightweight Only 4 9 in 124 mm Deep and 4 4 Ib 2 kg Connectivity USB 2 0 Host Port on the Front Panel for Quick and Easy Data Storage USB 2 0 Device Port on Rear Panel for Easy Connection to a PC or Direct Printing to a PictBridge compatible Printer Includes Tektronix OpenChoice Software for Connecting Your Bench 5 year Warranty Tektronix Datasheet Trio d CHI i l i at 930 0ns iiririvigigiiiiiisitini 142 OTSMHZ i 24 160m Cursor 1 360ns 440my Cursor 2 ofUns l 200m CH1 10 5m bHIIIFEI DI CHI 1 004 Quickly and easily capture waveforms E Ready CHI Rising bHIITITFEI DI
4. United Kingdom amp Ireland 00800 2255 4835 USA 1 800 833 9200 European toll free number If not accessible call 41 52 675 3777 Updated 10 February 2011 For Further Information Tektronix maintains a comprehensive constantly expanding collection of application notes technical briefs and other resources to help engineers working on the cutting edge of technology Please visit www tektronix com Copyright Tektronix Inc All rights reserved Tektronix products are covered by U S and foreign patents issued and pending Information in this publication supersedes that in all previously published material Specification and price change privileges reserved TEKTRONIX and TEK are registered trademarks of Tektronix Inc All other trade names referenced are the service marks trademarks or registered trademarks of their respective companies 20 Nov 2012 3GW 28557 1 Tektronix
5. fast and easy communication between a Windows PC and the TBS1000 Series using USB Transfer and save settings waveforms measurements and screen images Oscilloscope and probe exercises in PDF and MS Word oscilloscope basic features amp functions poster and primers Covers labor and parts for defects in materials and workmanship for 5 years excluding probes and accessories 3 Probes and accessories are not covered by the oscilloscope warranty and Service Offerings Refer to the data sheet of each probe and accessory model for its unique warranty and calibration terms Digital Storage Oscilloscopes TBS1000 Series Power Plug Options Option Description AO North America power Al Universal Euro power A2 United Kingdom power A3 Australia power A5 Switzerland power A6 Japan power A10 China power A11 India power A12 Brazil power A99 No power cord or AC adapter www tektronix com 7 Datasheet Language Options Translated front panel overlays included with their respective user manuals 4 Option Description LO English front panel label on instrument L1 French front panel overlay L2 Italian front panel overlay L3 German front panel overlay L4 Spanish front panel overlay L5 Japanese front panel overlay L6 Portuguese front panel overlay L7 Simple Chinese front panel overlay L8 Standard Chinese front panel overlay L9 Korean front panel overlay L10 Russian front panel overlay 4 User manuals P
6. DF in 11 languages are available on the CD and for download from www tektronix com manuals There are no printed user manuals Recommended Accessories Accessory Description TEK USB 488 GPIB to USB converter AC2100 Soft Carrying Case for Instrument HCTEK4321 Hard Plastic Carrying Case for Instrument requires AC2100 RM2000B Rackmount Kit 077 0444 xx Programmer Manual English Only 077 0772 xx service Manual English Only 174 440 1 xx USB host to device cable 3 ft long 8 www tektronix com Recommended Probes Probe TPP0101 TPP0201 P2220 P6101B P6015A P5100A P5200 P6021 P6022 A621 A622 TCP303 TCPA300 TCP305 TCPA300 TCP312 TCPA300 Description 10X Passive Probe 100 MHz bandwidth 10X Passive Probe 200 MHz bandwidth 1X 10X Passive Probe 200 MHz bandwidth 1X Passive Probe 15 MHz 300 Vrms CAT II rating 1000X High voltage Passive Probe 75 MHz 100X High voltage Passive Probe 500 MHz High voltage Active Differential Probe 25 MHz 15 A 60 MHz AC current Probe 6 A 120 MHz AC current Probe 2000 A 5 to 50 kHz AC current Probe 100 A 100 kHz AC DC Current Probe BNC 150 A 15 MHz AC DC Current Probe Amplifier 50 A 50 MHz AC DC Current Probe Amplifier 30 A 100 MHz AC DC Current Probe Amplifier TCP404XL TCPA400 500 A 2 MHz AC DC Current Probe Amplifier Service Options 5 Option D1 Description Calibration Data Report 5 Probes and accessories are not covered by the oscilloscope warranty an
7. FFT FFT Windows Hanning Flat Top Rectangular 2048 sample points Sources 2 channel models CH1 CH2 CH2 CH1 CH1 CH2 CH1 x CH2 Autoset Menu Single button automatic setup of all channels for vertical horizontal and trigger systems with undo Autoset Signal Type Autoset Menu Choices Square Wave Single Cycle Multicycle Rising or Falling Edge Sine Wave Single Cycle Multicycle FFT Spectrum Video NTSC PAL Field All Odd or Even SECAM Line All or Selectable Line Number Autorange Automatically adjust vertical and or horizontal oscilloscope settings when probe is moved from point to point or when the signal exhibits large changes Display Characteristics Characteristic Description Display QVGA Active Color TFT Interpolation Sin x x Display Types Dots vectors Persistence Off 1 s 2 s 5s infinite Format YT and XY Multiple language User Interface and Context sensitive Help Description English French German Italian Japanese Korean Portuguese Russian 2 Simplified Chinese Spanish Traditional Chinese 2 Requires Russian firmware indicated by RUS suffix Characteristic Languages Available 6 www tektronix com Environmental and Safety Characteristic Description Temperature Operating 0 to 50 C Nonoperating 40 to 71 C Humidity Operating and Up to 80 RH at or below 40 C nonoperating Up to 45 RH up to 50 C Altitude Operating and Up to 3 000 m nonoperating Electrom
8. V div 45 V Bandwidth Limit 20 MHz for all models AC DC GND on all models 1 MQ in parallel with 20 pF Input Coupling Input Impedance Time Base Range 5 ns to 50 s div Time Base Accuracy Horizontal Zoom 50 ppm Horizontally expand or compress a live or stopped waveform I O Interfaces USB Ports USB host port on front panel supports USB flash drives USB device port on back of instrument supports connection to PC and all PictBridge compatible printers GPIB Optional Nonvolatile Storage Reference Waveform Display 2 2 5k point reference waveforms Waveform Storage without USB Flash Drive 2 2 5k point Maximum USB Flash Drive Size Waveform Storage with USB Flash Drive 64 GB 96 or more reference waveforms per 8 MB Setups without USB Flash Drive Setups with USB Flash Drive Screen Images with USB Flash Drive Save All with USB Flash 10 front panel setups 4000 or more front panel setups per 8 MB 128 or more screen images per 8 MB the number of images depends on file format selected 12 or more Save All operations per 8 MB Drive A single Save All operation creates 3 to 9 files setup image plus one file for each displayed waveform 1 Bandwidth is 20 MHz at 2 mV div all models Acquisition Modes Mode Description Peak Detect High frequency and random glitch capture Captures glitches as narrow as 12 ns typical at all time base settings from 5 us div to 50 s div Sa
9. agnetic Meets Directive 2004 108 EC EN 61326 2 1 Class A Compatibility Australian EMC Framework Safety UL61010 1 2004 CSA22 2 No 61010 1 2004 EN61010 1 2001 IEC61010 1 2001 Physical Characteristics Instrument Dimensions mm in Width 326 3 12 85 Height 158 0 6 22 Depth 124 2 4 89 Weight kg Ib Instrument Only 2 0 4 4 With accessories 2 2 4 9 Instrument Shipping Package Dimensions mm in Width 476 2 18 75 Height 266 7 10 5 Depth 228 6 9 0 RM2000B Rackmount mm in Width 482 6 19 0 Height 177 8 7 0 Depth 108 0 4 25 Ordering Information Models Model Description TBS1022 25 MHz 2 Ch 500 MS s TFT DSO TBS1042 40 MHz 2 Ch 500 MS s TFT DSO TBS1062 60 MHz 2 Ch 1 GS s TFT DSO TBS1102 100 MHz 2 Ch 1 GS s TFT DSO TBS1152 150 MHz 2 Ch 1 GS s TFT DSO Standard Accessories Accessory Passive Probes One per Channel Power Cord NIM NIST Printed Documentation English Japanese and Simplified Chinese Documentation on CD OpenChoice PC Communications Software TDS Educator s Resource Kit CD 5 year Warranty Description TPP0101 100 MHz passive probe for TBS1022 TBS1042 TBS1062 and TBS1102 TPP0201 200 MHz passive probe for TBS1152 Please specify plug option Traceable Certificate of Calibration Installation and Safety Manual Detailed User Manuals English French German Italian Japanese Korean Portuguese Russian Simplified Chinese Spanish Traditional Chinese Enables
10. d Service Offerings Refer to the data sheet of each probe and accessory model for its unique warranty and calibration terms Tektronix is registered to ISO 9001 and ISO 14001 by SRI Quality System Registrar GPIB IEEE 488 Product s complies with IEEE Standard 488 1 1987 RS 232 C and with Tektronix Standard Codes and Formats Digital Storage Oscilloscopes TBS1000 Series www tektronix com 9 Datasheet www tektronix com Contact Tektronix ASEAN Australasia 65 6356 3900 Austria 00800 2255 4835 Balkans Israel South Africa and other ISE Countries 41 52 675 3777 Belgium 00800 2255 4835 Brazil 55 11 3759 7627 Canada 1 800 833 9200 Central East Europe and the Baltics 41 52 675 3777 Central Europe amp Greece 41 52 675 3777 Denmark 45 80 88 1401 Finland 41 52 675 3777 France 00800 2255 4835 Germany 00800 2255 4835 Hong Kong 400 820 5835 India 000 800 650 1835 Italy 00800 2255 4835 Japan 81 3 6714 3010 Luxembourg 41 52 675 3777 Mexico Central South America amp Caribbean 52 55 56 04 50 90 Middle East Asia and North Africa 41 52 675 3777 The Netherlands 00800 2255 4835 Norway 800 16098 People s Republic of China 400 820 5835 Poland 41 52 675 3777 Portugal 80 08 12370 Republic of Korea 001 800 8255 2835 Russia amp CIS 7 495 7484900 South Africa 41 52 675 3777 Spain 00800 2255 4835 Sweden 00800 2255 4835 Switzerland 00800 2255 4835 Taiwan 886 2 2722 9622
11. gnal to a user defined template R pady o Wi d tl erste 10 tare Gn tia bi RIE RIO Supunna Ninna CHI so ca JL 7 08 lt 10Hz Data Logging enables automatic saving of triggered waveforms 24 hours You can also select the Infinite option for continuous waveform monitoring With this mode you can save your triggered waveforms to an external USB memory device without a duration limitation until the memory device is full The oscilloscope will then guide you to insert another USB memory device to continue saving waveforms www tektronix com 3 Datasheet Easy PC Connectivity Easily capture save and analyze measurements results by connecting to your PC with the rear panel USB device port and the included copy of OpenChoice PC Communications Software Simply pull screen images and waveform data into the stand alone desktop application or directly into Microsoft Word and Excel Alternatively if you prefer not to use your PC you can simply print your image directly to any PictBridge compatible printer Performance You Can Count On In addition to industry leading service and support every TBS1000 Series oscilloscope comes backed with a 5 year Warranty as standard Education Resources Every TBS1000 model includes an Education Resource CD filled with tools to help your students master the use of an oscilloscope The Education Resource CD includes two Student Labs and Instructor s Guides and two Primers The Introductio
12. mple Sample data only Average Waveform averaged selectable 4 16 64 128 Single Sequence Use the Single Sequence button to capture a single triggered acquisition sequence Roll At acquisition time base settings of gt 100 ms div Trigger System Characteristic Description Trigger Modes Auto Normal Single Sequence Trigger Types Trigger Description Edge Conventional level driven trigger Positive or negative slope Rising Falling on any channel Coupling selections AC DC Noise Reject HF Reject LF Reject Video Trigger on all lines or individual lines odd even or all fields from composite video or broadcast standards NTSC PAL SECAM Pulse Width or Trigger on a pulse width less than greater than equal to or glitch not equal to a selectable time limit ranging from 33 ns to 10 s Trigger Source Characteristic 2 channel Models Description CH1 CH2 Ext Ext 5 AC Line www tektronix com 5 Datasheet Trigger View Displays trigger signal while Trigger View button is depressed Trigger Signal Frequency Readout Provides a frequency readout of the trigger source Cursors Characteristic Description Types Amplitude Time Measurements AT 1 AT AV Automatic Waveform Measurements Period Frequency Width Width Rise Time Fall Time Max Min Peak to Peak Mean RMS Cycle RMS Cursor RMS Duty Cycle Phase Delay Waveform Math Characteristic Description Operators Add Subtract Multiply
13. n to Oscilloscopes Student Lab and Instructor s Guide explains the basics of oscilloscope operation complete with hands on exercises for your students The ntroduction to Oscilloscope Probes Student Lab and Instructor s Guide explains the fundamentals of probing and how probes can affect measurement quality The two Primers included are the most popular and widely used from Tektronix the XYZs of Oscilloscopes and ABCs of Probes 4 www tektronix com The included Education Resource CD is filled with tools to help students master the use of an oscilloscope le x E Ute RED NAW MAD B O IAM SEQ BOW HHO 7 8 X Dergaha BE J gt j Mix B Aria 710 B Z U E SSB RX i658 Het Do A ta tata 4 BAY ER QHSARMBF 1065 BE v fs A B c D E F G H J K L M N O P Q R SER 16 CH1 Volts CH2 Volts Si 2 00000254 26 98 Aug 22 08 04 49 13 PM 3 00000254 26 98 4 00000253 26 1 00 5 00000253 20 1 00 ok SIRO E 6 00000253 22 1 04 Er To SQ92985LLNS 7 00000253 20 1 04 8888383838388555 58 8383833832398 8 00000253 18 1 00 8883888888888888 9 00000252 20 M ee ew es E eS Se ai 10 00000282 12 1 02 11 00000252 14 1 02 12 00000252 14 1 02 A 13 00000252 12 1 02 Saas 14 00000251 10 104 CH2 Volts 15 00000251 08 1 04 16 00000251 08 1 02 17 00000251 08 102 R 18 00000251 04 1 02 19 0000025 04 1 04 20 0000025 02 1 02 21
14. rs and students Featuring the same user interface as the Tektronix TDS Oscilloscope Family your students will learn to operate the world s most popular oscilloscope platform with over 500 000 oscilloscopes in operation worldwide To simplify integration with your existing curriculum the TBS1000 also includes an Education Resource CD filled with tools to help your students master the use of an oscilloscope The TBS1000 offers the tools and performance you need at a price you can afford Critical Tools for Troubleshooting Your Device Advanced triggers rising falling edge pulse width and video help you quickly isolate your signals of interest Once you ve captured a signal advanced math capabilities and automated measurements can speed your analysis Quickly perform an FFT or add subtract or multiply waveforms sixteen automated measurements quickly and reliably calculate important signal characteristics such as frequency or rise time while the built in Limit Test function enables you to easily identify problems in your signal Designed to Make Your Work Easy The TBS1000 Series oscilloscopes are designed with the ease of use and familiar operation you have come to expect from Tektronix Intuitive Operation The intuitive user interface with dedicated per channel vertical controls auto setup and auto ranging makes these instruments easy to use reducing learning time and increasing efficiency graticule Use m
15. ultipurpose knob to scroll The context sensitive Help system provides important information specific to the task you are working on Help When You Need It Where You Need It The built in Help menu provides you with important information on your oscilloscope s features and functions Help is provided in the same languages as the user interface Probe Check Wizard Check out your probe compensation before making measurements with just one button that starts a fast easy procedure Limit Test The oscilloscope can automatically monitor source signals and output Pass or Fail results by judging whether the input waveform is within predefined boundaries Specific actions can be triggered on violation including stopping waveform acquisition stopping Limit Test functions saving the failed waveform data or screen image to a USB memory device or any combination of the above This is an ideal solution for manufacturing or service applications where you need to make decisions quickly Flexible Data Transfer The USB host port on the front panel enables you to save your instrument settings screenshots and waveform data in a flash The built in Data Logging feature means you can set up your oscilloscope to save user specified triggered waveforms to a USB memory device for up to Digital Storage Oscilloscopes TBS1000 Series IT ae CH3 n Reta TERES k Limit Test provides a quick Pass Fail comparison of any triggered input si
Download Pdf Manuals
Related Search
Related Contents
GA-EX58-UD3R Acelerador de fluxo tipo ABS SB 900 até 2500 Instruções de Braun TrueScan BPW4300 APC SURTA48XLBPJ www.phoenixwaterfilters.com.au User Guide Manual de instruções - SITRANS LVL100 - the Infuser™ Buffalo 8-port SMB 10/100 Switch Copyright © All rights reserved.
Failed to retrieve file