Home
11400-Series - Helmut Singer Elektronik
Contents
1. With compliments Helmut Singer Elektronik www helmut singer de info helmut singer de fon 49 241 155 315 fax 49 241 152 066 Feldchen 16 24 D 52070 Aachen Germany The 11401 und 11402 are the first in a line of high bandwidth programmable digitizing oscilloscopes The 11401 11402 are ideal for digitizing and accurntely measuring repetitive wanetorms 10 14 bit vertical resolution 20 MSs AD conversion system provides a cost effective Wiution to a wide range of measurement problems 1 GHz and 500 MHz DIGITIZING OSCILLOSCOPES 11400 Series Digitizing Oscilloscopes The 11400 Series complies with IEEE GPIB standard 488 1978 RS 232C and with IEEE 488 Toktronix Standard Codes and Formats 1 GHz and 500 MHz Bandwidth e Eight Channels of Display and Acquisition Plug in Modularity e Waveform Processing and Automatic Pulse Parameters e Multiple 10 240 Point Waveform Records Accepts Differential High Impedance and 50 2 Input Amplifiers e Greatly Simplified Access to Features e Fully Programmable via GPIB and RS 232C TYPICAL APPLICATIONS Waveform Characterization Prototype Troubleshooting and Debugging Measurement Against a Standard The 11401 and 11402 are the first ina new line of digitizing oscilloscopes These ver satile scopes with their array of new sup porting plug ins and probes solve measurement problems equally well ona designer s bench or in a programmable test system
2. Digital designers will benefit from flexible triggering features and an eight channel display Analog and power supply designers can apply extensive waveform processing to signals acquired through high performance differential and single ended amplifiers 11000 Series digitizing scopes can follow your designs into production Full programmability via either IEEE 488 or RS 232C and features like a DMA controller for fast waveform transfers make these scopes a perfect fit for systems 11000 Series digitizing oscillo scopes set new standards in performance Live Display of Up to Eight Traces The 11401 11402 each support three vertical amplifier plug ins This means you Can acquire up to eight channels of data at 300 MHz up to six channels of data at 600 MHz or up to three channels of data at GHz You can of course mix and match the plug ins to design the system that works best for you Eight traces can be displayed at any one time so that you can get the whole picture on one screen The update rate is so fast that the 11401 and 11402 have the look and feel of analog scopes TEK 1 GHz and 500 MHz i DIGITIZING OSCILLOSC OPES L PEKEN The 11402 Digitizing Oscilloscope with 1 GHz System bandwidth High Vertical and Horizontal Resolution The 11401 and 11402 uniquely combine wide bandwidth with 10 ps horizontal resolution and 10 bit vertical resolution vertical resolution can be increased to
3. and Sensitivity DC Coupled 0 35 div from de to 50 MHz in creasing to div at 500 MHz Noise Reject Coupled 1 2 div or less from de to 50 MHz increasing to 3 div at 500 MHz AC Coupled 0 35 div from 60 Hz to 50 MHz increasing to 1 div at 500 MHz Attenuates signals below 50 Hz HF Reject Coupled 0 5 div from de to 30 kHz LF Reject Coupled 0 5 div from 80 kHz to 50 MHz increasing to div at 500 MHz Holdoff Range 500 ns to 10 s MEASUREMENT SYSTEM Waveform Processing Functions Waveform Functions Differentiate integrate interpolate smooth average and envelope Anthmetic Operators Plus minus multiply divide square root logn absolute value signum exp Measurement Set Amplitude Measure ments Min max mid mean peak peak RMS Timing Measurements Rise fall width delay l main window period propagation delay and frequency Area and Energy Area Area energy Cursors Single or dual dots split 11000 SERIES 20ne7a16 ans 1 98n Powerful waveform processing functions let users defne traces such as the power waveform shown above The top waveform is a voltage waveform and the bottum waveform is a power waveform created by squaring the voltage waveform and dividing it by a load resistance or paired mode horizontal and vertical bars measurement zone delimiters CRT AND DISPLAY FEATURES Standard CRT 4 in diagonal monochrome magnetic deflection Vertical raster
4. scan orientation Standard Phosphor GH P31 Video Resolution 552 horizontal by 704 ver tical displayed pixels POWER REQUIREMENTS Line Voltage Ranges 90 to 132 V RMS 180 to 250 V RMS Line Frequency 48 to 440 Hz Maximum Power Consumption 320 W ENVIRONMENTAL AND SAFETY Temperature Operating 0 to 50 C Non operating 40 to 75 C Humidity Operating and Nonoperating Up to 95 relative humidity up to 50 C Altitude Vibration Shock Bench Han dling Mects MIL T 28800C Type HI Class 5 Direct hard copy output to dot matrix printers is provided through a standard Centronics port 4 Hard copies are time and dale stamped for archiving 4 dns Main Size 2B UbUnss div Meir Pes 1h fins Remayve Pens Zaoa 28ne div Meature sente Mag Codere hie References Kfe i LI off Main The 11401 and 11402 offer a unique combina tion of accurate timing and accurate amplitude measurements in one cnstrument Electromagnetic Compatibility Meets MIL T28800C MIL STD 461B FCC Part 15 Subpart J Class B VDE 0871 6 78 Class B CE O1 Part 4 with exceptions CE 03 Part 4 Curve 1 CE 03 Part 4 Curve 4 Navy NB BB with ex ceptions CS OL Part T CS 02 Part 4 with ex ceptions CS 06 Part 5 RE O1 Part 4 with ex ceptions RE O2 Part 4 RS 01 Part 4 RS 03 Part 7 limited to 1 GHz Safety Listed UL 1244 CSA Bulletin 5456B September 1973 Tektronix self certific
5. 14 bits when signals arc averaged Other vendors have made a tradeoff bandwidth for vertical resolution or vertical resolu tion for bandwidth The 11401 11402 give you both for making demanding voltage and timing measurements in one box In addition the 11401 11402 s trigger to tigger measurement feature delivers 200 ps precision on single shot time A B measurements and can even provide 10 ps precision with averaging Trigger lo irigger measurements of this nature are only available on the 11401 11402 and a few expensive standalone counter timers Also window records can be used to increase horizontal resolution on specific segments of main records to pro vide a clear picture of signal details Multiple Long Record Lengths The 11401 11402 can acquire multiple records of up to 10 240 points each No other scope can capture as much data at once on repetitive waveforms The main frames can contain up to 102 400 points of waveform memory with Option 2D Long records and large storage capacity combine to let users gather data over relatively long periods of time with high resolution and improve measurement ac curacy One doesn t need a computer to log waveform data Waveforms can be stored on board the scope for later analysis Versatility for a Wide Range of Applications Five plug ins and new probes bring out standing versatility to the 11401 11402 The measurement system and waveform processing functions lead to quick
6. ation or mainframe or run diagnostics over a modem GPIB and RS 232C menus let you match interface parameters with a con troller modem or host If speed is a con sideration the parallel interface provided by the IFEE 488 port should be used A DMA option can be added to speed up GPIB data transfers even further Whichever bus is chosen the instruments respond to a logical set of Tektronix Standard Codes and Formats commands that make it easy to write your test procedures Accurate Automatic Measurements The only reason oscilloscopes exist is for making measurements The 11401 and 11402 perform waveform processing functions pulse parameter analysis cur sor functions and trigger to trigger measurements that combine to cover a full range of measurement needs A special annotation mode shows where measurements are being made on the trace so users can feel confident that they are on target Dot cursors can be split SBus div i 2us div Source Level ut 13 580mv Mode Cousling Siope flute BtNoiseRes Two built in time bases provide the func tionality of delaying and delayed sweeps in analog scopes The main time base defines the overall acquisition interval and the window time base allows high resolution acquisition of small portions of complex waveforms between two waveforms to make propa gation delay measurements or compare voltages Measurement zones can be set to limit the automatic measurement to a po
7. ation to comply with EC 348 recommendations PHYSICAL CHARACTERISTICS Cabinet Rackmount Dimensions mm in mm in Width 448 76 483 190 Height 238 94 222 88 Deptn 599 236 550 216 Weights kg Ib kg Ib Net 19 316 220 480 Shipping 28 0 620 3 4 889 ORDERING INFORMATION 11401 500 MHz Programmable Digitizing Oscilloscope Neludes Operator guide 070 56103 00 operator reference 070 5791 00 power cord 61 066 00 incoming inspection procedure 070 5694 00 1402 1 GH2 Programmable igitizing Oscilloscope Neludes Same as 11401 Ons OPTIONS Manaus 1C Cable Feedthroughs dds eight rear to front feed throughs in i i Single or dual 10x 10 division axes may be brought up for waveform display Each axis represents a full 10 bit digitizing window Option LR Rackmount Includes Hardware tooling and in structions for converting bench model to rackmount configuration Option 2D Memory Expansion Expands total waveform memory to 102 400 points for storage of waveform records Option 4D DMA Controller In creases data transfer speed over GPIB INTERNATIONAL POWER PLUG OPTIONS Option Al Universal Euro 220 V 50 Hz Option A2 UK 240 V 50 Hz Option A3 Australian 240 V 50 Hz Option A4 North American 250 V 60 Hz Option A5 Switzerland 240 V 50 Hz WARRANTY PLUS SERVICE PLANS See Customer Services and Information section in the back of this catalog S O On Site P
8. engineer TRAINING Tektronix Instrument Group Customer Train ing offers operation and application training to help you get full value out of your in strumentation investment See Customer Training section for information or call 1 800 835 9433 ext 430 In Oregon call 1 629 1017 collect
9. ing Rate 20 MSs maximum Main Record Positioning Position of the main record with respect to the trigger point of the main record Pretrigger 1 record dura tion Posttrigger 1 record duration Resolution main record point Windows In addition to the main record either one or two window records may be ac quired and displaved The window records may be of a different length duration and may have a smaller tunesdiv than the maim record If two window records are used they have the same duration and time div setungs and can be positioned independently Window Record Positioning The window records are positioned relative to a window trigger point which may be positioned relative to the main record s trigger point delayed by either time or events Main Window Time Measurement The time between the MAIN record trigger and the WINDOW trigger can be measured precisely even if each trigger occurs only once Repetitive events allow this measurement to be averaged for better resolution and accuracy Single Trigger Precision 200 ps Repetitive Precision 10 ps after 100 averages Accuracy 250 ps 0 002 of record duration TRIGGERING SYSTEM Range Full screen Bandwidth 500 MHz maximum A high resolution display with Point Accumulate Mode along with powerful trigger ing makes it much easier to capture and display common digital fault conditions like metastable states glitches and race conditions Coupling
10. ion make possible settling time measurements to within a fraction of a percent The Most Accurate Instruments of Their Kind The 11401 and 11402 are the most ac curate high bandwidth scopes on the market They combine the timing ac curacy inherent in digital time bases with 1 vertical accuracy The Enhanced Ac curacy feature prompts the user to start self calibration routines whenever temperature or configuration changes Warrant it You can even assign the 11401 11402 to start a self calibration automatically Time base accuracy is Trig Main The 1401 and 11402 can display up to eight traces from a variety of sources Display eight channets of live waveforms for timing analysis on digital systems or display combinations of lire and stored wareforms 100 ps 0 002 of the measured time in terval The 11401 and 11402 s accurate automatic measurements can replace dedicated counter timers and ac voltmeters Devices and subassemblies can be tested to tighter tolerances im proving end product performance and quality On Site Serviceability These scopes are card modular they have extensive self test and diagnostic routines and reliability built in On site Warranty Plus service options help you keep the in struments up and running when down time might otherwise halt your produc tion line Tektronix service technicians can be at your facility repairing these products within eight working hours if you are within 75 mile
11. rd Cen tronix port and software drivers compat ible with Tektronix 4644 and low cost Ep son dot matrix printers Overall the operation of the 1140111402 is intuitive The instrument can be used easily even if it is not used every day Acquisition measurement and documentation is as simple as six touches Auto set measure measurements rise exit hard copy It doesn t get any simpler Plug In Modularity The 11401 and 11402 are compatible with five different vertical amplifiers Each scope will accept three of these amplifiers in its plug in compartments You can con figure a scope to meet vour particular needs for example e Timing Measurements on High Speed Logic Use three 11A71s in the 11402 for three 1 GHz bandwidth channels e Characterization of Waveforms ina Lab Select an 11A52 for two high bandwidth 50 2 channels an 11A33 for high bandwidth differential measure ments and an 11A34 for four high impedance channels e Prototype Troubleshooting and Debugging Use two each four channel amplifiers and a two channel high bandwidth amplifier This configuration gives you eight channels of acquisition for timing analysis and two high bandwidth channels for exacting pulse response measurements e Power Supply Evaluation Use three differential amplifiers to determine efficiency and stability and TO measure noise and ripple DAC and Operational Amplifier Set tling Time Fast overdrive recovery and up to 14 bits of resolut
12. roduct Installation and Set Up 1 11401 1 Year On Site Service S1 11402 1 Year On Site Service OPTIONAL ACCESSORIES Power Supply Extended Diagnostics Order 067 1264 00 Service Manual Order 070 6779 00 Camera C 4 Option 10 Cables GPIB 2 m Order 012 0991 00 RS 232C 10 ft Order 012 0911 00 Centronics 10 ft for hard copy output Order 12 0555 00 Blank Panel For empty compartments Order 016 0829 00 ES fr The 11401 and 11402 are easily integrated in to automated test systems Options for rack conversion rear to front signal routing and DMA transfer of waveform data and measure ment results make the 11401 11402 ideal for systems applications Extender Board Order UAT 1267 D0 Hard Copy Unit Tektronix 4644 Dot Matrix Printer Recommended Probes See recom mended probes later in this section Recommended Cart K217 See In strument Cart Compatibility chart in the Accessories section To order contact your local Tektronix Sales Office SOFTWARE SUPPORT 11400 Series IBM PC Utility Waveform measurement data log ging graphics and statistical analysis GPIB and RS 232C support Order S47P 102 11400 Series Asyst Driver Menu driven package for scope con trol waveform acquisition data log ging and FFT analysis Order S47P303 For more information on utility and applica tion software see System Support section or consult your local sales or applications
13. rtion of a displayed trace Users can set proximal distal and mesial levels to customize timing measurements Up to six measurement results can be displayed and continuously updated as the data changes This lets users make adjustments and see the results quicker than ever before A direct hard copy output is pro vided that includes time and date of the measurement for archiving A Measurable Advance in Oscilloscope Technology Higher bandwidths better resolution more accuracy more versatility hardware and software modular easier to use and service the 11000 Series sets new stan dards for digitizing oscilloscopes CHARACTERISTICS VERTICAL SYSTEM Accuracy With Enhanced Depends on plug in unit Equivalent Time Bandwidth Depends on plug in used See Maximum Bandwidth Matrix in the 11000 Series Reference section Vertical Resolution 10 bits 1024 levels Resolution can be increased to 14 bits 16384 levels using signal averaging Accuracy TE K GHz ang 500 MHz DIGITIZING OSCILLOSCOPES 1083 High bandwidth allows capture and measure ment of fast rise times Measurements can be customized and annotated to clearly shon where and how the measurement is being made HORIZONTAL SYSTEM Time Bases Two identical built in time bases Record Duration 5 12 ns to 1024 s in 1 2 5 sequence Time Base Accuracy 100 ps 002 of measurement interval Record Length 5l2 points to 10 240 points Sampl
14. s of designated U S Service centers Probe Interface We ve set a new standard for probe inter facing Signal and probe power connec tions are all made at the amplifier input eliminating extra probe power lines We can support as many active probes as you have channels A smart serial interface etween the probe and the scope lets you top worrying about the proper termina tion impedance it is set automatically Ou can autoset the scope or sequence hrough a series of front panel set ups all from the probe ID button This leaves your hands free to probe your circuit A ull complement of active and passive compere ond Reference Cospare amp va on Ad just Referen Max Pin i 2 Ret Ret 674 7mV 1 7963 49 Perias Riee Faji ef Raf Ref 149 68n3 1 5043ns 1 3752ns Mis Width m 23 a Rise 096p 50 7p 320 4 Multiple waveform parameter measurements can be performed and are updated continuous ly A compare and reference measurement mode allows measurement results to be com pared to a standard and the difference of two results to be displayed probes with this new interface is ready to assist in the solution to your measure ment problems Choose Your Computer Interface The 11401 and 11402 have both IEEE 488 and RS 232C interfaces as standard features for data transfer and instrument control The RS 232C port lets you con trol the instrument with a PC upload or download waveforms from a workst
15. solu tions to a wide variety of voltage time area and energy problems The 1 GHz 11402 can process and measure signals from high bandwidth 50 2 amplifiers high impedance amplifiers and differen tial amplifiers 1 mV sensitivity and 500 V maximum input voltage let users capture small signals from transducers or monitor ac power lines Fast overdrive recovery and up to 2000 divisions of dvnamic range give these scopes the power to look at even the smallest detail on difficult to capture waveforms Unparalleled Ease of Use The 1140 and 11402 use simple parallel menus and touch screen to give easy ac cess to their measurement and display features All but a few of the buttons and knobs have been eliminated in favor of a system that only presents selections when they are valid and or useful An autoset function sets up the scope for you based upon the signal characteristics of the selected trace This function can be activated from the probe tip allowing for hands off operation of the scope Autoset frees the operator to concentrate on the measurement problem and the probe con nection The most commonly used func tions are no deeper than a second menu level Icons let you assign the knobs to waveform size and position no matter what operating mode you are in Pop up 41009 ____ SERIES menus present choices and fold down when those selections are made ne button hard copy generation is Made possible by the use of a standa
Download Pdf Manuals
Related Search
Related Contents
QICAM 10-bit User`s Manual Troubleshooting Guide (English) Hewlett Packard Enterprise ProLiant 385 G7 Gigaset C530 Chief PDR2133B flat panel wall mount Operating and installation instructions Manuel d`utilisation orientationpaca mobi Severin BR 7951 DK-KP85PH Operation Copyright © All rights reserved.