Contents
1. 3 microns Miscellaneous Motors and Electrical 1 HP Motor 1 PH 3450 RPM for Dust Cab 800 Units 1 HP Motor 3 PH 3450 RPM for Dust Cab 800 Units 3 HP Motor 3 PH 3450 RPMfor Dust Cab 1500 Units 1206 01 On Off Switch SECTION 5 Maintenance Operation amp Maintenance Eventually the filter bag will become loaded with dust and the design airflow or suction will diminish To clean the filter bags shake the handle on the side of the cabinet this will wrap the underside of the filter bags dropping the dust off the bags into the drawer Shake the bags every four hours more often if the dust loading is heavy If the dust does not release from the bags then the dust is either wet and sticky or the dust is so small that it does not have any weight to fall off the outside surface of the bag filters Lubrication or other routine periodic preventative maintenance is not required All that is needed is an occasional check of fasteners hoses and clamps and a general visual check of the unit to make sure that nothing has gone wrong Periodic replacement of the bag filters is required when necessary Always empty the dust storage before it fills completely Do NOT allow the dust to collect to the point where it begins to touch the bottom of the filter bags since this would result in the dust being re entered into the air stream re depositing on the filters and shortening their life Ifa hopper and stand is supplied Do NOT use the hopper as a d
2. internal wiring is UL rated at 600 volts Input power line protection is required for the motor and electrical components Line load and current requirements are identified on themotor nameplate Unless ordered with the machine the power switch for operating the machine any fusible disconnect motor starter or controller are to be provided by the customer user and located externally to the machine 3 All connections to the non standard units are made at the motor electrical box three phase amp 230V single phase Wiring diagrams can be found on the motor nameplate or on the motor electrical box Verify the incoming voltage and that the motor has been properly wired prior to connecting it to the machine 4 Verify proper rotation of the blower motor It will be necessary to view the blower wheel from the blower exhaust on the Dust Cab series unit to verify the rotation Proper rotation is marked on the motor housing The blower wheel should be rotating clockwise when viewed from the motor end of the wheel Counterclock wise from the blower inlet cone side of the wheel If opposite rotation is experienced see Figure 2 for directions to switch rotation NOTE A motor starter with overload protection must be provided by the User Thermal overload heaters are installed in the external motor starter Consult the starter manufacturer for recommended heater size for the installed motor SECTION 3 Installation continued Electrical WARNI
3. single phase motor The Dust Cab 1500 is designed for 1500 CFM and uses a 3 HP three phase motor The filter area in the 800 is 55 square feet and the 1500 has 180 square feet of media Inlet size is 4 inch on the 800 and 8 inch on the 1500 Optional Accesories 1 HEPA Module The HEPA Module is bolted on the rear of the Dust Cab 800 after the blower and uses a 12 inch x 24 inch x 12 inch deep HEPA filter rated for 99 97 efficiency at 0 3 micron particle size The HEPA Module for the Dust Cab 1500 is a bolt on cabinet that is attached after the bag filter but before the motor blower and uses a 24 inch x 24 inch x 12 inch deep HEPA filter rated for 99 97 efficiency at 0 3 micron particle size Portable Caster Frame The portable caster frame allows both the Dust Cab 800 and 1500 to be moved along the floor Filter Media Options Polyester felt media is a good option if you need a more efficient filter bag for finer dusts Other medias are available upon request Spark Trap A bolt on spark trap can be added to the inlet of the Dust Cab to reduce the amount of sparks entering the collector SECTION 1 Optional Accessories continued 5 Downdraft Table Top The downdraft table top is an add on to the top of the Dust Cab 800 Collector to capture dust from grinding or deburring while working ona table top Hopper Floor Stand Hoppers and floor stands are available for the Dust Cab Series when an increase of dust storage is r
4. to list all of the potential hazards that may be encountered with air pollution control systems It is therefore important that the application of the equipment be discussed with an AER Control Systems representative or application engineer prior to use Additionally users should consult and comply with all National and Local Fire Electrical and or other appropriate codes when determining the application location and operation of any air pollution control equipment Collection of combustible or explosive materials and collection on flame or spark generating operations may require specific system configurations contact AER Control Systems LLC Applications Engineering Department for questions and or design assistance The combined collection of combustible or explosive materials and contami nants from spark or flame generating operations with acommon collector or duct system is not recommended unless special design provisions have been made to the system sparks or flames resulting from such operations may ignite the combustible or explosive material Under no circumstances should anyone be allowed to discard a lighted ciga rette other burning materials or refuse into an inlet hood or the duct of the collection system It is the responsibility of the end user to comply with all applicable national state and local fire and safety codes This manual should be read completely before attempting Operation or Maintenance of this equipment All
5. ALR Control Systems Installation amp Service Manual For Dust Cab Series Collectors MODELS Dust Cab 800 Dust Cab 1500 March 4th 2004 Table of Contents 3 MANADA ARNE e aa 4 SE 4 Optional GUIDING TE 5 Applications General eha 5 Applications continued esye ir ke Ak 6 IS Cell ATOM E E A E T 6 700601 INE STT 7 Electrical Installation Continued 8 Figure 1 Wire Connection Diagram 8 Ordering Replacement Parts trte 9 Maint jaN E al cated eats ca ell 10 TOUTS KOVAL t 11 Specifications serci ere a conse 12 Aa 13 Disclaimer Although instructions and recommendations are included for installation of your Dust Cab Series Collector equipment the manufacturer does not assume responsibility for the installation of this equipment nor shall he be held liable for direct or consequential dam ages resulting from improper installation application maintenance or use The immense variety of contaminants make it impossible
6. NG Permanent damage to the motor will be sustained if connected to voltages other than the normal operating voltage for which the unit is pre wired Low Voltage High Voltage Low Voltage High Voltage 4 6 5 4 8 5 2 68 8 9 8 7 9 8 T 3 4 5 2 1 3 2 1 1 2 4 Line Line Line Line Interchange any two line wires to reverse rotation to change rotation flip 5 amp 8 Phase Single Phase Figure 1 Wire Connection Diagram SECTION 4 Ordering Replacement Parts Information required for prompt delivery of replacement parts will be 1 Model and Serial Number 2 Number and Description Contact your local AER Control Systems LLC distributor for replacement parts Use either our toll free telephone number or our website www aercontrolsystem com to obtain the nearest AER Control Systems LLC distributor s name and telephone number 1 866 265 2372 Description Part Number Miscellaneous Hoses and Clamps 4 x 10 Neoprene Polyester Flexhose 1051 01 6 x 10 Neoprene Polyester Flexhose 1051 02 1051 06 8 x 10 Neoprene Polyester Flexhose Hose Clamp 4 Bridge 1050 10 1050 11 Hose Clamp 6 Bridge Hose Clamp 8 Bridge 1050 12 Miscellaneous Filters Dust Cab 800 Cotton Sateen Bag Dust Cab 800 Polyester Felt Bag Dust Cab 1500 Cotton Sateen Bag Dust Cab 1500 Polyester Felt Bag HEPA Filter 12 x 24 x 12 99 97 3 microns HEPA Filter 24 x 24 x 12 99 97
7. ections to and from the starter and collector No Power To Unit indicator light is not lit Motor Fails to Start Check wires from input electrical box on the collector to the motor Check motor wiring Check to see if motor is faulty Power to unit indicator light is lit Check rotation of blower If running backwards interchange 2 of the 3 input power leads 3 phase motors only Blower is running backwards Low airflow and or suction Filter bags are not being cleaned Shake filter bags Check ducting for blockage Check for dampers in the duct system they may be closed Improper duct design Obstruction in ducting Hole in the filter bag Replace filter bag Contaminant blowing out of the collector exhaust Check that filter bag frame is oriented so that it lines up with knife edge inside the cabinet Check the seal on top of filter bag gasket Filter bag not properly installed Specifications ee ESU ee em 6 Control Systems __ Limited Warranty AER Control Systems LLC warrants all products sold only to purchasers for use in busi ness or for resale against defects in workmanship or materials under normal use for one 1 year after the date of purchase from AER Control Systems LLC Misapplication of the product decomposition by reaction or chemical action and wear caused by abrasion will not constitute or be considered as a defect Warranty is void i
8. equired 30 gallon or 55 gallon drum kits are also optional Optional Equipment Motor Starters Custom Designs Motor Voltages Phase amp Cycles Activated Carbon SECTION 2 Applications General 1 Dust smoke amp vapor The Dust Cab Series Collectors are designed for the capture and removal of dust smoke amp gas vapor contaminants from a wide variety of manufacturing processes The standard filter bag material is a cotton sateen The cotton sateen bag is good for abrasive and coarse contaminants such as metals wood coarse talc and corn starch An optional polyester felt bag is a more efficient filter on finer dusts such as ceramic cast iron plastics graphite fine talc toner and fiberglass A twill bag is good for any dust contaminant that is slightly wet If smoke is being generated in the process a HEPA filter can be added to the Dust Cab Series Collectors Activated carbon can be added as an option to collect gas vapor contaminants Size It is important that the proper size unit has been selected for the application Too little airflow will not draw the contaminant into the filter and the unit will not becompletely effective Too much airflow may result in loss of efficiency or the unit will pick up large or heavy solid particles increasing the frequency ofmaintenance or filter replacement Questions regarding proper unit sizing should be directed to your local AER Control Systems representative or the main office t
9. f the product has been subject to damage unreasonable use neglect improper service improper installation or other causes not arising from defects in original materials or workmanship Any part that is determined to be defective in material or workmanship and returned to an AER Control Systems LLC distributor or authorized service facility as AER Control Systems LLC designates shipping costs prepaid will be as the exclusive remedy repaired or replaced at AER Control Systems LLC s option AER Control Systems LLC shall not be liable for any incidental or consequential cost expenses or damages resulting from any failure defect or malfunction of this product liability is expressly disclaimed AER Control Sys tems LLC s liability in all events is limited to and will not exceed the purchase price of the product Title and risk of loss pass to the buyer on delivery to the common carrier If a product is damaged in transit the recipient MUST make note of the damage upon receipt of the product and file a claim with the carrier AER Control Systems LLC will make a good faith effort for prompt correction or other adjustment with respect to any product that proves to be defective within the warranty period Collection of combustible or explosive materials and collection on flame or spark generat ing operation any require specific system configurations contact AER Control Systems LLC s Applications Engineering Department for questions and or desi
10. gn assistance The combined collection of combustible or explosive materials and contaminants from spark or flame generating operations with a common collector or duct system is not recom mended unless special design provisions have been made to the system sparks or flames resulting from such operations may ignite the combustible or explosive material Under no circumstances should anyone be allowed to discard a lighted cigarette other burning materials or refuse into an inlet hood or the duct of the collection system It is the responsibility of the end user to comply with all applicable national state and local fire and safety codes AER Control Systems LLC s liabiltiy for consequential and incidental damage resulting from a fire or explosion is expressly disclaimed Installation of suitable overload protection such as a motor starter according to NEC guidelines is required Failure to provide proper overload protection will void warranty coverage on electrical components in the system Combination motor starters with fusible disconnect packages are available through your local AER Control Systems LLC representative To ensure optimum collector performance always use AER Control Systems LLC replacement filters
11. oll free 866 265 2372 SECTION 2 Applications continued 3 Models The two models for the Dust Cab are the 800 and the 1500 The 800 and the 1500 identifies the nominal airflow for the unit Ifa HEPA filter is included then a H would be added to the model for example Dust Cab 800H A carbon filter would have a C to identify if the unit has carbon Ifthe Dust Cab 1500 is portable then a P would be after the 1500 for example Dust Cab1500P 4 Collars Ducted source capture units are provided with inlet collars for attaching ductwork 5 Portable Units The 800 and the 1500 are available with four casters for portability SECTION 3 Installation Assembly and Installation Dust Cab Collectors Standard Collectors are pre assembled for the 800 and 1500 with exception to optional items such as hopper stand and drum kits Standard collectors are free standing and are typically located in a central location near to the operations needing collection SECTION 3 Installation continued Electrical 1 Single phase 115V 60HZ units are standard prewired from the factory and include an On Off switch wired to the electric motor with a power cord for single phase power Single phase 230V and three phase units are an option but do not include a switch cord or plug All three phase and 230V single phase units are wired for the input voltage specified on the purchase order 2 Motors used on the Dust Cab series collectors are UL recognized and
12. ust storage device Dust Cab Filter Replacement 800 amp 1500 The pressure drop across the bag filters will eventually reach a point at which the airflow and suction are too low At this time the bag filters should be replaced as follows 1 Shut off electrical power to the blower and control box 2 Open the bag filter access door on the front of the filter bag cabinet 3 Unscrew the nuts from the four bag filter lifting bolts two on either side of the filter The bag filter support frame will drop down allowing the bag filter to slide out of the support rails inside the cabinet 4 Slide the bag filter out on the rails Remove the filter for inspection or replacement 5 Reinstall the bag filter by sliding the filter into the cabinet on the rail Tighten the four nuts on the bolts to lift the support frame and the bag filter into a knife edge inside the cabinet compressing the gasket on the filter frame to seal the bag Make sure the gasket on the filter frame is hitting the knife edge inside the cabinet 6 Close the bag filter access door SECTION 6 Troubleshooting If after performing the above TROUBLE SHOOTING the unit fails to perform to specifica tions contact your AER Control System s Representative for further assistance In the unlikely event local help is unavailable contact the factory for engineering assistance Check overload heaters in starter and fuses replace or reset if necessary Check for proper wire coon
13. work should be performed by qualified personnel according to local requirements All data and dimensions in this manual have been thoroughly checked however we cannot assume responsibility for possible errors or omissions We reserve the right to change designs and or specifications without notice WARNING Failure to comply fully with the following instructions and local code requirements may increase your risk of physical injury due to fire explosion or electrical shock SECTION 1 Uncrating 2 Remove banding and cardboard shipping carton and packing Hoppers Plenum Boxes and Attenuators are typically labeled and packed with the unit to be installed mounting hardware is included for mounting these items Be sure to check all boxes for any miscellaneous parts or hardware items before discarding Inspect the exterior of the unit and accessories for shipping damage or shortages that may not have been noticed or recorded when the shipment was initially received you have 30 days to notify AER Control Systems LLC of any discrepancies Contact the shipping company if any damage or shortages have occurred Description amp Operation The standard Dust Cab Series Collectors consist of a removable dust drawer an enve lope style flame retardant cotton sateen bag filter with a manual shake cleaning mecha nism and a blower motor with a built in silencer The Dust Cab 800 Collector is designed for 800 CFM and uses a 1 HP
Download Pdf Manuals
Related Search
Related Contents
O motivo da nossa existência Eu lhe proponho agora um pequeno MT 3060 User Guide_MT3060X-UG001 nShield: A Noninvasive NFC Security System for Mobile Devices Untitled - Innovaciones MS Fujitsu M4097D User's Manual Freeman Exhibitor Services Manual (2015) 取扱説明書 recall J TOLEDO SUZUKI MOTOS DO BRASIL-GSXR750 利用規約のダウンロードはこちら Mode d`emploi Copyright © All rights reserved.