Home

MONSTER AG TT

image

Contents

1. 64 MONSTER AG TT Technical assistance manual Notes MONSTER AG TT Technical assistance manual 65 Notes 66 MONSTER AG TT Technical assistance manual Notes MONSTER AG TT Technical assistance manual 67 PA CORGHI CORGHI S p A per Carpi n 9 42015 CORREGGIO RE ITALY Tel 39 0522 639 111 Fax 39 0522 639 150 www corghi com info corghi com COMIM Code 4 329712_uk 02 10
2. 2 1 O _ _ _n O o oa oo I II 2 GND30 SIGNALING MONSTER AG TT Technical assistance manual Table 10 1 Description of the LEDS on the CPU RX2 board DEFINITION Comment and or reference value POWER OUTPUT LEDS from LDI Power output LEDS OUT 1 Green Outputs in DC 30V not stabilised to LD24 OUT 24 solenoid valves Each of these LEDs is associated with a solenoid valve LD1 to YVI LD2 to YV2 up to LD24 associated with YV24 They must turn on each time the relative valve is powered Note LED LD24 turns on each time the second translation speed is activated because this output is reserved for use with the Radio Update Kit LD25 Hydraulic control unit motor Green Output in AC 25V LED in second speed This LED must turn on each time the motor of the hydraulic control unit turns in second speed It can never be ON together with LD26 LD26 Control unit motor LED in first Green Output in AC 25V speed This LED must turn on each time the motor of the hydraulic control unit turns in first speed It can never be ON together with LD25 DIGITAL INPUT LEDS LD27 Digital input LED DIN 1 Red This LED turns on when the sensor connected to connector X20 supplies an active signal LD29 Digital input LED DIN 2 Red This LED turns on when the sensor connected to connector X21 supplies an active signal LD32 Digital input LED DIN 3 Red This LED turns on when the sensor connected
3. AND 8 SECTION A T For correct assembly the check plate must have the right clearance with the tool arm support and with the washer that keeps it in position See detail C The check plate fits into a milled part on the bottom of the tool arm where it must be free to slide To slide freely there must be an 0 2 mm clearance between the check plate and end position of the tool arm support Tolerance 0 0 2 mm This plate has a slot inside which a cylindrical spacer is to be inserted A washer is to be placed on this spacer which will keep the plate in place There must be a clearance of 0 3 mm between the washer and plate Tolerance 0 0 2 mm To guarantee a correct assembly it might be necessary to have to increase or reduce the shim between the tool arm and support as explained above in detail B If the tool arm support ever needs replacing pay attention to eliminating clearances with the tool car riage 40 diam shims are foreseen for the pin that acts as the pivot Maximum clearance 0 2 mm 18 MONSTER AG TT Technical assistance manual Replacing the tool arm rotation cylinder If the tool arm rotation cylinder ball joint or check plate has to be replaced you will have to adjust the ball joint so the cylinder does not reach the end of its stroke there should be 0 5 to 1 mm left to the end To make this adjustment move the rotation cylinder to the end of its stroke tighten or l
4. push button which is on the control panel to confirm continuing with the procedure Forced switching on of the laser Laser func tioning test Dip switch 48 has the dual function of forcing switching on of the laser and testing its opera tion Access to one function or the other depends on the status of the machine when the dip switch is turned ON The purpose of this mechanism is to avoid leaving the laser on all the time forgetting dip switch 48 ON Forced switching on of the laser The laser is normally off and is turned on only on the following occasions For 2 seconds when switching the machine on During the Side To Side STS function If the technician needs to keep the laser on for test purposes e g aligning the beam checking for parasitic reflections or malfunctions etc he can use dip switch 8 to force its switching on To force switching on of the laser proceed as follows 1 Make sure the machine is already on 2 Turn dip switch 48 ON The laser turns on im mediately and stays on To remove forced switching on of the laser turn dip switch 48 OFF If you forget and leave dip switch 8 ON and you then turn the machine off when turning on the next time the machine goes to the laser functioning test programme described in the next paragraph Laser functioning test The laser functioning test not to be confused with the laser Programming procedure described in chapter 9 verifies tha
5. Solenoid valve sensor and board connections SEE USER MANUAL Figure 1 2 Wiring diagram part 2 Powersupply motor and transformer connections SEE USER MANUAL Figure 11 3 Wiring diagram part 3 Internal con nections on the control column SEE USER MANUAL 11 2 Physical layout of the electrical system The electrical system is housed inside an electri cal board located on the same structure as the hydraulic control unit All the cables lead from this electrical board to the various parts of the machine motors sensors etc All cables are laid inside corrugated sheaths for greater protection 48 MONSTER AG TT Technical assistance manual Figure 11 4 Physical layout of the electrical board A El 4 mmmmnnnrn Wn n n Hn pp E EI HN L e a E 5 1 amp 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 L eee ee ww www www www ww ew www www s MONSTER AG Technical assistance manual 49 11 3 Fuses The fuses protect
6. The purpose of programming is to set the laser operating parameters e g measuring range selection of the type of output etc on values suitable to be able to work on the machine 9 1 When to programme the laser Programming is not necessary because the lasers are already programmed when supplied How ever laser programming can be checked and repeated if necessary in the following cases When the machine is manufactured in the factory When a new laser is installed When there are doubts as to whether or not it is working properly It is necessary to check that the reference meas urements are stored Forthis check see chapters 9 2 9 3 and proceed with the first 4 steps if the measurement of 200 is already stored wait 15 sec onds to exit the programming mode Ifthe measurement of 200 is not stored proceed with the whole programming sequence 36 MONSTER AG TT Technical assistance manual A laser programmed machine can be used on another machine without having to repro gramme it 9 2 Preparing to programme the laser To programme the laser it must be connected to the machine s electrical system with the cable fitted with a 4 pole connector and powered Turn the machine on and then set dip switch 8 ON all the others must be OFF The dip switch is on the CPU RX2 board inside the electrical system When programming is finished rememberto turn the laser off by putting dip switch 8 OFF
7. 9 3 Laser programming sequence The sensor is programmed using the two push buttons Mode Enter and Set which are in the top part of the laser sensor just under the display See figure 9 1 Programme as follows Figure 9 1 Laser display and programming buttons POWER mm m inch OUT1 OUT2 When programming if the keys are not pressed for more than 15 seconds the laser returns to its initial status storing any changes made up to that point Press Action to be done The following Set by pressing continuously List of parameters analogue Keep pressed until U is output type displayed output live Mode Enter appears on the Remarks display EE UO ASP Analog Start Point Numerical values from 0 Keep pressed until 200 mm to 9999 is displayed Mode Enter Mode Enter Set by pressing continuously Numerical values from 0 Keep pressed until 1700 mm to 9999 is displayed Mode Enter 2 times Mode Enter 5 times Mode Enter Extended Functions Set by pressing continuously List of display parameters Keep pressed until OFF is displayed display OFF Wait 15 seconds without The parameters are stored at pressing any keys the end of 15 seconds MONSTER AG TT Technical assistance manual 37 Note To see the distance value even when the display is off press the Mode Enter button once the display turns back on for 15 seconds showing the distance At the end of programming it is advisable to run t
8. Technical assistance manual 3 MECHANICAL PART 1 FIRST CHECKS AFTER INSTALLATION Carry out the following checks after connecting to an electrical socket Monster and AGTT 1600A 1600 versions 1 1 1 1 1 1 1 Perform a complete stroke for each hydraulic cylinder Check maximum pressure setting which must be 180 bar Check the level of oil in the control unit With all the cylinders closed there must be 5 cm between the dipstick and the plug without screwing it down Check the levelling off of the base If the cus tomer primarily uses heavy duty wheels level with one wheel locked on the turntable In the case of very heavy duty wheels it is advisable to turn the foot one more time The chassis is designed to absorb jolts due to the heavy weight Checking the 3 turntable rotation speeds Low speed has only one rotation direction Speed performance might not be good whenthe machine is cold Heat the oil for a few minutes by moving the cylinders Even the QS2 switch can be used to heat the oil it keeps the control unit ON and the oil moving But the second translation speed will not work in this way Check that if there is a radio connection it is subject to no interference and does not create interference with any nearby equipment MONSTER version Check tool tangent and bead breaker disc posi tion at 22 5 and at 42 At22 5 there must be 27 mm between the tool pad and bead seat on th
9. Technical assistance manual 53 Grease oil and dust do not influence proximity switch reading 12 2 Adjusting the horizontal tool micro switch To adjust the horizontal tool micro switch SQ3 consult the mechanical part of the service manual 12 3 Adjusting the left rotated tool micro switch To adjust the left rotated tool micro switch SQ4 consult the mechanical part of the service manual 12 4 Replacing the potentiometer The potentiometer that measures radial dis placement requires no mechanical adjustments If the potentiometer has to be removed and or replaced simply fix it to the machine and hookits steel cable on the steel hooking up sheet See the relative chapter in the mechanical section The steel cable must be parallel with the bar to achieve maximum linearity in reading Therefore adjust the hooking up sheet as illustrated in figure 12 2 Figure 12 2 Adjusting parallelism of the poten tiometer s steel cable Subsequentto replacing reassembly calibration has to be done Chapter5 followed if necessary by the global correction procedures of the bead breaker disc tangent Chapter 7 and or global correction of the tool tangent Chapter 8 12 5 Connecting and adjusting the acoustic luminous indicator The acoustic luminous indicator identified by on the wiring diagram can work in different modes depending onthe type of connection The indicator on this machine must work intermit
10. Technical assistance manual 55 Operating modes Table 13 1 summarises the machine s operating modes Table 13 1 Operating modes ALARM LED RX ON LED CABLE LED DISPLAY Access red white green level NORMAL ofi MODE MANUAL 56 MODE Blinks quickly when automatisms are required otherwise it is off Blinks quickly until the machine turns off as soon as an automatism is asked for It blinks very slowly the on off cycle lasts 2 s It blinks when commands are received It blinks when commands are received It blinks when commands are received Off for at least 20 seconds then blinks if commands continue ar riving On with a steady light if the cable is connected otherwise it is off On with a steady light if the cable is connected otherwise it is off On with a steady light if the cable is connected otherwise it is off On with a steady light if the cable is connected otherwise it is off It stays in the status itwasin before enter ing the Stop Mode Variable messages Variable messages Variable messages Variable messages or OFF It displays STOP for at least 20 seconds END USER END USER END USER END USER Standard working mode Ifthereis no display or it malfunctions the automatisms cannot be used only the manual controls can If there are no cali bration data the automatisms can not be used only the manu
11. There are no adjustments to be done on the potentiometer buffer board 10 3 Display board The display board DISPLAY SGP58 has four figures each with 7 segments plus a decimal point The following information is shown from time to time on the display The diameter set in inches or mm Information messages short messages or ab breviations Error codes e g E00 The values or messages displayed are usually fixed ifthey are blinking it means the machine is waiting for confirmation or for the operator to do something in some cases press a key in others release a key or maybe via the dip switches or the push button The presence of the display is indispensable for using the automatic functions if there 15 no display any request made for an automatic function is refused and the machine signals this condition with the red ALARM LED blinking on the electrical board See visual signalling Table 13 2 for this The display communicates serially with the electronic control board with RS232 electrical levels Communication is bidirectional the display respondsto each command ofthe control board with a received signal There are no adjustments to be done on the display board Figure 10 3 Display board SGP58 10 4 Radio modem RX unit The RX radio modem receives the serial flow of data sent via radio by the homologous TX unit mounted on the trolley that houses the control console Once the data
12. battery or via an emergency serial cable When the battery is nearly flat the LOW BATT LED yellow visible on the control console turns on to remind the operator it needs recharging using the charger supplied with the machine When the control console is connected to the machine with an emergency serial cable the battery is not recharged The LD5 LED green on the CPU TX board but not visible on the outside must turn on each time the emergency serial cable is used to signal that the board is being fed via cable and not by battery Figure 10 4 Electronic transmission board CPU TX LOW BATT MATAN ASNO A JOYSTICKS and SWITCHES BATTERY JOYSLICKS and SWITCHES LI 50055 999559995 555 EXPANSION FOOTSWITCHES STOP BUTTON SERIAL CABLE Four LEDS are on the board which are easy to see from the outside plus another one that cannot be seen from the outside Their meanings are given in table 10 6 MONSTER AG TT Technical assistance manual 47 Table 10 6 Description of the LEDs on the transmission board CPU TX DEFINITION Comment and or reference value Green TX ON This LED must turn on each time a command is activated and must turn off when there are no more commands activated Red This LED turns on and stays on the whole time the STOP STOP push button is pressed Note the STOP push button is not an emergency stop Yellow
13. 4 12 MONSTER Technical assistance manual 2 12 Replacing the wire potentiometer Open the junction box disconnect the potentiometer cable from the board and unscrew the cable gland checknut Disconnect the sensor wire Undo the screws supporting the potenti ometer Replace the potentiometer Repeat the above steps described for as sembly but in the reverse order Calibrate as described in the electric electronic part of the Service Manual 3 SLIDING BLOCKS UNIT This new sliding block has the characteristic of being able to recover the clearance that is acquired with the passing of time The upper part dark grey in the picture is fixed to the carriage on which it is assembled whereas the lower part light grey is able to slide thanks to the slanting tops by turning the adjusting screw It is this sliding that allows clearance to be recovered created during operation It is of paramount importance to know the mechanism and the adjustment methods for a perfect tyre changer operation On these sliding blocks it is possible to adjust the width and height of the plate on which they slide MONSTER AG TT Technical assistance manual 13 3 1 Adjusting the width This is the same adjustment made to all the tyre changers in production By means of the two M12 dowels move the fixed part up against the sliding plate and then go back a quarter of a turn Tighten the checknut Tighten
14. 4 pole connector Supplies a 30V voltage in output Outputs to control speed 5 pole connector Photo coupled outputs and rotation direction of the There are three bits on this connector motor inverter 51 52 and S3 to control the speed and rotation direction of the motor inverter See table 10 4 RXON LED white 2 pole connector It provides a 5V voltage in output to drive the led ALARM LED red 2 pole connector It provides a 5V voltage in output to drive the LED CABLE LED green 2 pole connector It supplies a 5V voltage in output to drive the LED 42 MONSTER AG TT Technical assistance manual XI X2 X3 X4 X7 X6 X12 X13 X14 X15 DEFINITION Comment and or reference value ANALOG INPUT CONNECTORS Analog input channel AIN 1 4 pole connector This connector receives in input the signal of the potentiometer used for the radial displacement movement Supplies a 20V voltage in output Analog input channel AIN 2 4 pole connector Not used at present Supplies a 20V voltage in output Analog input channel AIN 3 4 4 pole connector Not used at present Supplies a 20V voltage in output Analog input channel AIN 4 4 4 pole connector This connector receives in input the laser signal used for the Side to Side function STS Supplies a 20V voltage in output DIGITAL INPUT CONNECTORS Digital input channel DIN 1 3 pole connector This connector receives in input the signal of t
15. breaker disc described in the next paragraph 32 MONSTER AG TT Technical assistance manual Figure 7 1 Nominal bead breaker disc rim distance values in the bead breaker disc tangents 27 mm lt 24 5 45 mm gt 24 5 7 3 How to set global bead breaker disc tangent correction To set the procedure for global correction of the bead breaker disc tangent proceed as follows 1 Turn the machine on and mount a 22 5 metal sheet rim on the turntable 2 Carry out an automatic tangent procedure on the bead breaker discand then move the rim with the manual controls up to the distance with the bead breaker disc deemed optimum 3 Turn the machine off open the electrical board and put dip switch 2 on the electronic control board ON no other dip switch must be ON 4 Turn the machine back on dip2 appears blinking on the display 5 Put dip switch 2 OFF for two seconds Corr disc followed by a blinking numerical value now appears on the display indicating the global cor rection value of the bead breaker disc tangent currently stored on the electronic control board This value will be between 128 and 127 Newelectronic control boards are supplied with a global bead breaker disc tangent correction value equal to 0 The numerical value displayed is an internal machine parameter and does not represent the rim bead breaker disc distance expressed in millimetres or inches Positive values move the bead br
16. have been received via radio it sends them always serially with TTL electrical levels to the CPU RX2 control board through a flat 10 pole cable The RX radio modem can only receive data via radio and not transmit via radio There are no indicator lights on the RX radio modem unit There is a dip switch on the RX radio modem for selecting the radio channel to use receiving only 16 different radio channels are available that can be selected by a combination offourdip switches The same channel must be set on the homologous TX unit on the control console Radio channel set up The machines are delivered with the RX and TX radio modes set on radio channel 16 all dip switches OFF To set the communication radio channel proceed as follows 1 Switch the machine off 2 Disconnect the emergency cable if con nected 3 Open the RX radio modem using a cross slot ted screwdriver 4 Select the radio channel wanted by setting the four dip switches in the combination indicated in Table 10 5 MONSTER AG TT Technical assistance manual 45 5 Repeat the same setting on the TX radio modem Since the TX radio modem is connected to the control console which is normally battery powered and has no turning on switch the plastic cover must be removed under the console and the battery disconnected from the CPU TX board Now set the radio channel on the TX radio modem and reconnect the battery 6 Turn the machine on and run a funct
17. parcial con cualquier medio incluidos microfilmes y Es anol fotocopias Las informaciones contenidas en el presente manual pueden sufrir variaciones sin aviso previo Elaborazione grafica e impaginazione Ufficio Pubblicazioni Tecniche MONSTER AG TT Technical assistance manual TRANSLATION OF ORIGINAL INSTRUCTIONS TABLE OF CONTENTS 2 4 1 FIRST CHECKS AFTER INSTALLATION Ea Rs 4 2 TURNTABLE TROLLEY 2 2 SLIDING BLOCKS UNIT 13 A TOO 17 MA INT 20 6 HYDRAULIC 21 ELECTRONIC ELECT RIC PART 23 23 2 HOW THE MANUAL IS 5 23 3 AN OVERALL GLANCE AT THE MACHINE 24 A SERVICE PROGRAMME Sra 27 3 MACHINE CALIBRA HON sirena aora 29 ADVANCE STOPPING 2 4 30 GLOBAL BEAD BREAKER DISC TANGENT CORRECTION 32 8 GLOBAL TOOL TANGENT CORRECTION ociosa rindas 34 9 PROGRAMMING THE LASER SENSOR 36 10 ELECTRONIC BOARDS LAYOUT AND MEASURING POINTS 38 LA ADJUSTMENT Sist E E T 53 15 TROUBLESHOOTING 25 COMIM Code 4 329712_ uk dated 02 10 MONSTER AG TT
18. the screw securing the locking spring Take the pin out Unscrew the M 18x1 5 nut Replace the mobile clamp Insert 2 new plugs supplied with the machine or on request Refit the M18x1 5 bolt tightening the nut so the clamp is gripped in rotation and the pin fits into the two seats Refit the spring Insert the pin 2 5 Replacing the fixed clamp Open the turntable almost completely without reaching the end of travel Take the mobile clamp off by removing the M18x1 5 bolt Unscrew the other M 18x1 5 nut Unscrew the dowel locking the pin between the connecting rod and the fixed clamp Remove the pin and the M18x1 5 screw Replace the fixed clamp For assembly repeat the same steps for disassembly but in the reverse order Use medium strength Loctite 243 on the dowel locking the pin on the connecting rod Check tightness of the 18 1 5 nuts movements must be gripped 2 6 Replacing the hydraulic distributor Close the turntable Remove the protective casing Disconnect the hydraulic pipes Remove the 2 screws and the stop washer Pull the distributor out It is compulsory to use the cone for assembly as it prevents damaging the gaskets Refit the new distributor Repeat the same steps for disassembly but inthe reverse order Use medium strength Loctite 243 on the 2 screws locking the distributor Adjust clearance if necessary with the adjustment screw 2 7 Replacing
19. 13 2 Error codes and their meanings MEANING ACTION Calibration data missing Calibrate the machine If the error persists replace the CPU RX2 board This indication is always given also when installing a new board No signal on the analog channel Check the connection of the potentiometer and that 1 radial displacement measuring it is sound potentiometer If the error persists call for technical assistance No signal on the analog channel 2 this channel is not used at present No signal on the analog channel 3 this channel is not used at present No signal on the analog channel 4 Check the connection of the laser and that it is analog laser for Side To Side sound Also check that the front glass of the laser is not dirty If the error persists call for technical assistance E00 01 02 E03 E04 11 No signal on the digital channel 1 Check the connection of the proximity its soundness proximity chain link count and adjustment Chap 12 1 MONSTER AG TT Technical assistance manual 5T The figures or message displayed are normally fixed but in some cases can blink As a general rule applicable for all operating modes the following is true when the figures and or messages are blinking it means that the value displayed must be confirmed by the operator or is waiting for the operator to do something Acoustic indications via the display In all operating modes the display emits the beeps indica
20. 4 MONSTER AG TT Code 4 329712 uk dated 02 10 UL TA Technical assistance manua diritti di traduzione di memorizzazione elettronica di riproduzione e di adattamento totale o parziale con qualsiasi mezzo compresi microfilm e copie fotostatiche sono riservati It ali a no Le informazioni contenute in questo manuale sono soggette a variazioni senza preavviso ll rights reserved No part of this publication may be translated stored in an electronic retrieval system repro duced or partially or totally adapted by any means including E h microfilm and photostats without prior permission ng IS The information contained herein may be subject to modifica tions without prior notice LE droits de traduction de m morisation lectronique de reproduction et d adaptation compl te ou partielle partout de moyen y compris microfilms et copies photostatiques Fran Cal S sont r serv s Les informations fournies dans ce manuel peuvent tre modi fi es tout moment et sans pr avis lle Rechte der bersetzung der Speicherung Reproduktion sowie der gesamten oder teilweisen Anpassung durch ein beliebiges Mittel einschlie lich Mikrofilm und Fotokopien Deutsch sind vorbehalten Die in diesem Handbuch enthaltenen Informationen k nnen ohne Vorbescheid ge ndert werden uedan reservados los derechos de traducci n de me morizaci n electr nica de reproducci n y de adaptaci n total o
21. 50 MONSTER AG TT Technical assistance manual CPU RX2 board CPU RX2 board CPU RX2 board 1 gG Electrical board 400 V 3ph machines Electrical board MONSTER AG TT Technical assistance manual Automobile type blade fuse Reference ground GND30 This fuse protects the CPU RX2 board from short circuits on the solenoid valves or in their connecting cables If they blow the following LEDs turn off LD35 Self restoring fuse Reference ground GND30 This fuse protects the CPU RX2 board from short circuits on the external digital sensors or in their connecting cables No replacement is required to restore the fuse remove the cause for the short circuit If they blow the following LEDs turn off or become faint LD36 Glass fuse 5x20 mm delayed Reference ground GND AGND This fuse protects the CPU RX2 board from short circuits inside the logic part If they blow the following LEDs turn off or become faint LD37 LD38 Ceramic fuses 10 3x38 This pair of fuses protects both branches of the TCI transformer primary from short circuiting If they blow unplug the X5 connector from the CPU RX2 board replace the fuse and turn the machine back on If it blows again the problem could be the wiring of the white indicator lisht HLI or even the transformer itself If it does not blow plug the X5 connector back into the board and turn back on If it blows now replace the CPU RX2 board after ma
22. Chapter 5 12 1 Adjusting the proximity switch The proximity switch is used during the Side To Side function to count the links of the chain and therefore to know indirectly the relative position of the laser in relation to the edge of the wheel The working distance is to be adjusted as fol lows 1 Translate to the left or right until the most prominent part of the chain the convex part is facing the proximity switch 2 Ifthe proximity switch is faulty remove it and install the new one 3 Move the proximity switch near until there is a space of 2 mm between the flat surface of the sensor and the chain as can be seen in figure 12 1 and then tighten the two locking nuts by hand to keep it in position The LED on the body of the proximity switch must turn on 4 Tighten the two nuts with a spanner taking care that the distance is always 2 mm The tightening torque must not be too much otherwise it will damage the component 5 Translate several times to the right and left checking that the LED on the componentturns on and off at a rate of about 50 between turning on and turning off Also check that LED LD27 on the CPU RX2 board turns on and off at the same rate LED LD27 allows you to check that all the proximity switch s wiring up to the electronic board is working 6 Repeat the translations in second speed checking both LEDs Figure 12 1 Adjusting the working distance of the proximity switch MONSTER AG TT
23. I shown on the display 6 ADVANCE STOPPING CALIBRATION Tocarry outthe automatictangent functions bead breaker disc ortool with maximum precision and repeatability the machine anticipates stopping of the radial movement of the turntable clamp unit to compensate for the unavoidable inertia of the system The actual advance differs according to whether the turntable clamp carries out a radial UP or a radial DOWN displacement because the speeds are different The two advance values are stored inanon volatile memory and were defined atthe machine design stage to ensure the best results in terms of precision and repeatability Besides this set advance time the machine also performs a dynamic correction taking into ac count the positioning error made in a tangent 50 as to correct the calculation and execution of the next tangent However if for any reason the speed of the turntable clamp unit differs a great deal from what was foreseen at the design stage e g for replacing the hydraulic cylinder which performs aradial movement with aslightly different boring one it is possible to calibrate advance stopping so as to store the two advance values required for that particular machine NOTE This procedure is only available starting from the software release CG 1 0 incl This procedure is not enabled for previous soft ware releases dip switch 4 is not active 30 MONSTER AG TT Technical assistance manual 6 1
24. LOW BATT The LED turns on when the battery is low and must be recharged Red This LED must turn on each time a the push button F is pressed together with another key to access the second function of the latter If the key has no second function pressing the LD2 F button has not importance By pressing just the F key the LED does not turn on but the push button code is still sent to the machine and consequently the RX ON LED on the machine blinks Green NOT VISIBLE from the outside 5V The LED must turn on and stay on the whole time the board is powered with the emergency serial cable 11 ELECTRICAL SYSTEM The machine s electrical system is enclosed in an electrical board positioned next to the hydraulic control unit All the cables lead from this electri cal board each one is laid inside a corrugated sheath to guarantee maximum resistance to the two motors solenoid valves and to the sensors on the machine The electrical system is completed by the part on the trolley which houses the control console 11 1 Electrical system wiring diagram The machine s wiring diagram is shown in figures 11 1 11 2 and 11 3 A printed copy of the wiring diagram is inside a plastic envelope inside the electrical board This copy is always the most updated seeing as it is put in by the system manufacturer when tested so has priority over the diagrams in this manual or in other documents Figure 11 1 Wiring diagram part 1
25. T CORRECTION Chap 7 Dip switch 2 GLOBAL TANGENT CORRECTION OF THE TOOL Chap 8 Dip switch 3 Key APPLICATION COMPULSORY when replacing the CPU RX2 board with a new one or coming from another machine replacing and or removing and remounting the potentiometer OPTIONAL when replacing the CPU RX2 board with a new one or coming from another machine Tangent results are not exact and or repeat able and vary depending on the turntable clamp s direction RECOMMENDED when The hydraulic cylinder that provides radial movement to the turntable clamp is replaced The turntable clamp unit is removed and remounted COMPULSORY when replacing the CPU RX2 board with a new one or coming from another machine OPTIONAL when the potentiometer is replaced COMPULSORY when replacing the CPU RX2 board with a new one or coming from another machine OPTIONAL when the potentiometer is replaced when the tool is removed and or replaced the tool s micro switch is removed and or adjusted COMPULSORY the operation is indispensable if the cases listed in the box on the right occur OPTIONAL the operation is not indispensable but should only be done if the results are unsatisfactory RECOMMENDED the operation is not indispensable but is recommended anyway to be certain of getting the best results MONSTER AG TT Technical assistance manual Notes
26. When to calibrate advance stopping Advance stopping calibration is not strictly neces sary and must be done in the cases listed below only after having verified that the automatic tangent functions bead breaker disc or tool are not equally precise if the tangent is reached with the turntable clamp unit coming from the highest radial positions furthest away from the user or the lowest radial positions nearest to the user When animportant mechanical part of the turn table clamp unit is replaced e g the hydraulic cylinder When the hydraulic oil is changed with one whose characteristics differ from those fore seen When the hydraulic pump is replaced with one whose characteristics differ from those foreseen When the automatic tangent functions bead breaker disc or tool give results that are quite different depending on the starting position of the turntable clamp unit in relation to the final tangent position The operation is optional in the following cases When the machine is manufactured in the fac tory When anewelectroniccontrol board is installed never calibrated When an electronic control board is installed that was used before on another machine In these latter cases evaluate the need to calibrate advance stopping based on the results obtained with the tangents In all cases calibrating advance stopping must be done only after having calibrated the machine Chapter 5 6 2 V
27. al controls can This indication can only occur when switching on and means the display is disconnected faulty and a dip switch is ON at the same time Simply turn the dip switch off in order to con tinue working even ifonlyinthe manual mode The stop button has been pressed NOTthe emergen cy button Lasts at least 20 seconds but continues until all controls are re leased MONSTER AG TT Technical assistance manual otherwise it grammes for global is off corrections On witha Variable steady light It blinks wh FACTORY status based pon if the cable Variable Factory commands MODE on the com is connected messages staff are received ies mands given otherwise it is off Errors and signals on the display When working in the NORMAL MODE some occurs can occur that are described in Table 13 2 The error code is displayed Some errors prevent use of the machine s automatisms e g errors E00 and E01 or cause advance ending e g error El 1 By pressing the Clear key on the control panel the error code disappears from the display but the cause for the alarm is not removed so if the command that caused it is repeated the message will appear again On with a This operating steady light mode includes SERVICE 22 Elinks wen itthe cable variable Technical the Calibration Slow blinking commands assistance is connected messages and Setting pro are received personnel Table
28. all the commands except those for rotating the turntable clamp The solenoid valves are driven directly by the control board CPU RX2 58 MONSTER AG TT Technical assistance manual The function of the solenoid valve is to drain the oil BYPASS andis the normally opentypeso that the flow of oil is always drained into the tank all the time the valve is NOT powered as soon as it is powered it switches to the closed status rendering the oil available to the actuators solenoid valve is powered as soon as a commandis given tothe machine and unpowered only when there are no other solenoid valves powered All the other solenoid valves are the normally closed type and open hydraulically only when they are powered There is a correspondence between the com mands given on the control console and the solenoid valves This correspondence is direct in the case of manual commands one command powers just one solenoid valve most obviously YV1 In the case of automatic commands however several solenoid valves can be powered simul taneously and with some of these commands the solenoid valves can be powered in sequence determined by software based on the initial conditions of the machine This makes it harder to establish the correctness of powering the solenoid valves However it is still possible to check which solenoid valves are powered by observing the LD1 LD24 LEDs on the CPU RX2 board Each of these LEDs t
29. ary gives all the abbre viations and acronyms used in this technical manual CHAP 15 Thischaptergivesatable summarising the calibration and setting operations for global tangent corrections MONSTER AG TT Technical assistance manual 23 3 OVERALL GLANCE THE MACHINE The machine object of this manual is intended for demounting tyres for heavy duty use wheels for vehicles in the transport earth moving agriculture forestry sectors etc The machine allows a traditional type of use where the operator controls the actuators at his complete discretion manual mode or an innovative use where the onboard electronics executes some func tions automatically automatic modes The machine has some sensors for executing the functions automatically a potentiometer for tangent operations alaser and proximity switch for the Side To Side operations as well as some micro switches used in several functions If these sensors are missing or malfunctioning the automatic functions can be completely inhibited or performed incompletely Whatever the case the manual controls are always available Table 3 1 summarises the automatic and manual functions that are available together with their main features Table 3 1 Automatic and manual functions with their features f f i Function Remarks Type of command Manual commands Manual hands on Always available even if there are ongoing alarms relative to the automatic funct
30. bed in the next paragraph Figure 8 1 Nominal tool rim distance values in the tool tangents 27 mm lt 24 5 45 mm gt 24 5 MONSTER AG TT Technical assistance manual 35 8 3 How to set global tool tangent correction To set the procedure for global correction of the tool tangent proceed as follows 1 Turn the machine on and mount a 22 5 metal sheet rim on the turntable 2 Carry out an automatic tangent procedure on the tool and then move the rim with the manual controls up to the distance with the tool deemed optimum 3 Turnthe machine off openthe electrical board and put dip switch 3 on the electronic control board ON no other dip switch must be ON 4 Turn the machine back on dip3 appears blinking on the display 5 Put dip switch 3 OFF for two seconds Corr tool followed by a blinking numerical value now appears on the display indicating the global cor rection value of the tool tangent currently stored on the electronic control board This value will be between 128 and 127 Newelectronic control boards are supplied witha global tool tangent correction value equal to 0 The numerical value displayed is an internal machine parameter and does not represent the rim tool distance expressed in millimetres or inches Positive values move the tool away from the rim negative values bring it closer 6 Confirm the rim tool distance chosen at point 1 by pressing push button Pl on
31. e accessed via the set of SWI dip switches on the electroniccontrol board These dip switches are normally all in the OFF position as can be seen in figure 4 1 MICRO SWITCH To identify a certain dip switch the designation SWI X will be used where SWI is the name of the whole set and X the subject dip switch For example when it is written in the text to set dip switch SW1 2 ON it means that only dip switch 2 must be switched ON and therefore does not mean that dip switches 1 and 2 must both be switched ON Figure 4 1 DIP switches on the electronic control board Posizione normale A specific programme is associated with each one of these dip switches as indicated in table 4 1 MONSTER AG TT Technical assistance manual 27 Table 4 1 Service programmes available Reference DIP SWITCH ds Service programme function Chapter Setting esting eration E _ global correction factor of the bead breaker disc tangent Setting the global correction factor of the tool tangent from software release CG RO 18 Advance stopping calibration from software release CG RI _ _ switching on of the laser Laser functioning test Some service programmes require the use of the push button to confirm the values displayed or to continue with the procedure The push button is on the CPU RX2 board by the side of the SWI dip switch Other service programmes instead require the use of the
32. e of the box remove one or both the 0 2 mm rings inserted between the crown and the 3 mm steel ring Vice versa if the crown is below the level of the box edge add the necessary number of 0 2 mm rings to bring it up to the same level Assembly diagram detail C d l mm GIOCO TEORICO 3 mm IN ACCIAIO mm h BRON O ANELLI IM ACCIAIO Q mm X 1 7 ANELLI Os mm 10 MONSTER AG TT Technical assistance manual Once the crown is mounted correctly Insert the worm screw Fit the end position ring Tighten the 4 cylindrical head screws to 35 Nm Spread some medium strength Loctite 243 on the 4 dowels Mount the bearing pack as per the enclosed diagram The axial bearings must have the part with the smallest hole towards the outside of the bearing pack Tighten the nut on the first thrust bearing to 22 Nm then holding the latter still tighten the second nut Use full strength Loctite Once mounted check that the worm screw is not too gripped and is able to operate the gear unit Replace the gaskets on the three covers Fit the three covers Tighten the 7 screws on the gear unit cover to 12 Nm Tighten the eighth screw directly onto the aluminium taking care not to ruin the thread Refit the turntable cylinder distributor and pulley as explained in the relative chapters 2 9 2 Assembly diagram of bearings on the gear unit SCHEMA MONTAGGIO CUSCINETTI Cuscinett
33. e rim The same applies to the bead breaker disc At 42 there must be 45 mm between the tool pad and bead seat on the rim The same applies to the bead breaker disc If necessary correct the positions by means of the calibrations explained in the electric electronic part of the service manual With one wheel mounted enter the rim diam eter on the display and carry out a Side To Side procedure Check that the chain sensor blinks during the Side To Side Checking the tool s working position A distance of 160 mm between the centre of the ball joint and closing of the cylinder See the relative paragraph for more information 1600 1600 versions Checking tool arm rotation Checking the manual search mechanism Recommendations When working with wheels that are heavierthan 300 Kg use only the first rotation speed of the turntable spindle This will safeguard the gear unit and ensure a longer life Advise the customer to keep the sliding block guides well greased to protect them and ensure a longer life MONSTER AG TT Technical assistance manual 2 TURNTABLE TROLLEY UNIT GRUPPO RIDUTTORE DISTRIBUTORE CINGHIA e OLEODINAMICO MOTOINVERT SSF A CILINDR ANTE POTENZIOMETRO A FILO GRUPPO PATTINO AUTOCENTRANTE GRUPPO GRIFFA MONSTER AG Technical assistance manual 5 2 1 Replacing and tensioning the motor inverter belt R
34. e the machine with mains volt ages of 200 208 230 V three phase 50 60 Hz a transformer with a suitable power has to be used that transforms this voltage to 400 V 52 MONSTER AG TT Technical assistance manual THREE PHASE 200 208 230 400V 7 5 AUTO TRANSFORMER unitis available designed specifically for this application This unit consists of an electrical board inside which the actual auto transformeris housed Only the electrical cable for connecting to the room s mains socket leads from this board The machine s power lead must be inserted inside the electrical board and connected to the output terminals of the three pole fuse holder The auto transformer unit is supplied wired for a mains voltage of 230 V 3ph To use the mains voltages of 200 V or 208 V open the electrical system box and move the R S and T wires onto the relative terminals of the auto transformer Using the three phase auto transformer unit no adjustments of alterations are necessary of the machine s electrical connections 12 ADJUSTMENTS The following mechanical adjustments of the machine s sensors are required e Adjustment of the proximity switch Adjustment of the horizontal tool micro switch 503 e Adjustment of the right tool rotation micro switch SQ4 The adjustments are described in the following paragraphs The potentiometer on the other hand does not require mechanical adjustments but only a software calibration
35. e the target overthe whole laser measuring range and check that reading varies continuously This is a qualitative type check It is also possible to leave the target still in two or three positions to check that the value displayed is stable Butin this case the target must be absolutely stable Note the last digit of the value displayed could fluctuate even if the target is perfectly stable This fact is normal If on the other hand the fluctuation amplitude is too much the problem could even be due to the target used highly reflecting surfaces e g chromed or galvanised particularly dark e g certain types of rubber or transparent should not be used Use ordinary card or plastic not coloured Switch the machine off to exit the Laser func tioning test 5 MACHINE CALIBRATION The machine must be calibrated to be able to use the automatic bead breaker disctangent and tool tangent functions Itis atwo point calibration and is done by moving the turntable carriage into the all up and all down radial positions During calibration the only movements the ma chine can do are the Turntable UP and DOWN Radial Displacements 5 1 When calibration is to be done Calibration is to be done on the following oc casions When the machine is manufactured in the fac tory Whenanewelectroniccontrol board isinstalled and therefore has never been calibrated When an already calibrated electronic control board is installed bu
36. eaker disc away from the rim negative values bring it closer 6 Confirm the rim bead breaker disc distance chosen at point by pressing push button Pl on the electronic control board The machine shows the numerical value for one second on the display that corresponds to the global correction of the bead breaker disc tangent that has just been acquired MONSTER AG TT Technical assistance manual 33 Alternatively it is possible to set the numerical value directly of the global bead breaker disc correction with the and keys on the control panel limited to values ranging between 128 and 127 and then confirm by pressing Pl In this case however the physical distance between rim and bead breaker disc will be ignored and the value shown on the display will be stored 7 The machine now goes to the normal operating mode displaying the default diameter 22 5 not blinking Carry out the automatic bead breaker disc tangent function a few times to check that setting of the global tangent correction has been successful 8 If the rim bead breaker disc distance is what is wanted the procedure can be deemed com pleted and normal work can be started Otherwise global correction of the bead breaker disctangent will need varying again so repeat the procedure from point 1 Once inthe setting procedure if key Clear is pressedonthe control panelthe global correction value of the bead breaker disc is set directly at val
37. emove the casing Loosen the 4 screws securing the motor Loosen the nuts on the tie rod By means of the motor remove tension to the belt Replace the belt Tighten the belt by way of the nut on the tie rod Tension value 180 Hz Tighten the outside nut on the tie rod and the 4 screws of the motor Refit the casing 2 2 Replacing the pulleys Remove the casing Loosen the 4 screws securing the motor Loosen the nuts on the tie rod Remove the belt Loosen the screw locking the pulley Replace the pulley Tighten the screw using some medium strength Loctite thread locking agent 243 Refit the belt following the instructions given in the relative paragraph Check the tightness of the screw on the pulley you have just replaced 2 3 Replacing the motor inverter Remove the casing Loosen the 4 screws securing the motor Loosen the nuts on the tie rod Remove the belt Disconnect the cables of the motor inverter in the junction box Completely undo the 4 screws supporting the motor Replace the motor inverter For assembly repeat the same steps for disassembly but in the reverse order Use medium strength Loctite 243 on the 4 screws locking the motor Refit the belt following the instructions given in the relative paragraph Check tightness ofthe screw on the driving pulley 6 MONSTER AG TT Technical assistance manual 2 4 Replacing the mobile clamp Remove
38. erifying the need to calibrate advance stopping To verify the need for advance stopping calibra tion proceed as follows 1 Turn the machine on mount a 22 5 metal sheet rim on the turntable and check that 22 5 is shown on the display 2 Make sure the temperature of the hydraulic oil is between 35 and 40 C Temperatures that are considerably different from these could give incorrect results that will then effect the precision of the automatic tangents 3 Perform the automatic bead breaker disc tangent procedure several times starting the turntable clamp unit from opposite radial posi tions at least twice from all up and twice from all down and each time measure the distance between the bead breaker disc and the rim 4 Calculate the difference between the maximum and minimum distance measured at the end of the tangents If the difference is less than 10 mm it will not be necessary to calibrate advance stop ping and work can be started straight away with the machine If instead the difference is greater then it is better to calibrate advance stopping as described in the next paragraph 6 3 How to calibrate advance stopping Proceed as follows to calibrate advance stop ping 1 Turn the machine on and remove the wheel or rim if any from the turntable 2 Position the tool holder arm in the all up position 3 Manually carry out a complete up and down radial stroke of the turntable clamp unit to check
39. he laser functioning test procedure described in chapter 4 1 to check that programming has been done correctly 10 ELECTRONIC BOARDS LAYOUT AND MEASURING POINTS This chapter shows the layouts of the electronic boards used on the machine On each board the electrical measurement points are indicated and all the components that may be important during the troubleshooting phase Figure 10 1 Electronic control board CPU RX2 POWER OUTPUTS 2 1 30 MOTOINVERTER RADIO LED CABLE GN LED ALARM RD LED RX ON WH E BODDU B pe PGM DISPLAY 38 POWER OUTPUTS AIN 1 POTENTIOMETER POWER OUTPUTS 10 1 Electronic control board CPU RX2 The function of the electronic control board CPU RX2 is to receive the serial commands sent via cable or radio from the control console and to put them into practice driving the motors and solenoid valves on the machine as required The board also uses sensors potentiometer proxim ity switch laser as well as some micro switches for carrying out the automatic functions that are available suchas forexample tangent position ing of the bead breaker disc and demounting tool and the automatic bypassing of the wheel Side To Side The CPU RX2 is shown in figure 10 1 POWER GROUND POWER OUTPUTS E zi O
40. he proximity switch used for counting the chain links Supplies a 24V voltage in output Digital input channel DIN 2 3 pole connector This connector receives in input the signal of the tool micro switch in the horizontal position Supplies a 24V voltage in output Digital input channel DIN 3 3 pole connector Not used at present Supplies a 24V voltage in output Digital input channel DIN 4 3 pole connector This connector receives in input the signal of the tool micro switch rotated to the left Supplies a 24V voltage in output Digital input channel DIN 5 3 pole connector Not used at present Supplies a 24V voltage in output Digital input channel DIN 6 3 pole connector Not used at present Supplies a 24V voltage in output Table 10 4 Control signals of the speed and rotation direction of the motor inverter X16 X17 X18 X19 X20 X21 X22 X23 X26 X27 MONSTER AG TT Technical assistance manual 43 Table 10 4 Control signals of the speed and rotation direction of the motor inverter Control and relative LED indicator light Turntable Jane Speed rotation m LED Sn m TED direction a IE ETT 5 Other combinations NOT ALLOWED NOTE The rotation direction of the turntable clamp is reversed with respect to the rotation direction of the motor inverter shaft The CPU RX2 board could be faulty if there are other control signal combinations Fuses on the CPU RX2 board T
41. hen press the PI push button on the electronic control board The machine acquires the first calibration point and therefore shows Cal2 on the display blinking Actually point Call can be acquired indiffer ently with the turntable in the all up or all down radial position provided point Cal2 is acquired in the opposite position the software will auto matically put the two points acquired in order before storing 6 With the joysticks of the control panel move the turntable carriage into opposite radial posi tion and then press the PI push button on the electronic control board The machine acquires the second calibration point and shows the word END on the display blinking for 1 second 7 Calibration is complete and the machine goes to the normal operating mode displaying the default diameter 22 5 not blinking It is now possible to proceed with the advance stopping calibration see chapter6 ifthere are the conditions forit or continue trying the automatic tangent functions But if the automatic bead breaker disc tangent or tool tangent function fail to give optimum results carry out the global bead breaker disc and global tool correction procedures described in the relative chapters The potentiometer is required in order to cali brate Withoutthe potentiometer the electronic buffer board or if there are anomalies with the electrical connections the machine will exit the calibration procedure with the error code EO
42. here are seven protection fuses on the CPU RX2 board which are described in detail in table 11 1 in the chapter dedicated to fuses Two of these fuses are replaceable while the others are the self restoring type remove the short circuit and they return to their normal status 10 2 Potentiometer buffer board MFPOT4 The potentiometer buffer board is used to transmit the potentiometer signal to the CPU RX2 board so that it is not altered by the electrical interference in the environment The electrical signal in input to the MFPOT4 board connector X1 coming from the potentiometer is transferred in output connector X2 with an amplification equal to 1 consequently electrical meas urement of the input signal must always be the same as the signal in output The board is near the potentiometer and enclosed in a plastic box guaranteeing water tightness Figure 10 2 Potentiometer buffer board MFPOT4 SCALE 2 1 ANALOG OUTPUT Y m O 2 IT O A 44 MONSTER AG TT Technical assistance manual LED the board indicates the presence of the supply voltage 20V coming from the CPU RX2 board The CPU RX2 board is able to detect a failure on the MFPOT4 board no supply an internal break or faulty wiring In this case when the user requires an automatic function that uses the potentiometer signal the software programme prevents the function from being sent and shows the error code E01 on the display
43. in the halfway point of the worm screw steel ring and 2 mm bronze ring are positioned between the crown and the fixed part of the spindle seat For correct assembly there should be a gap of 0 1 mm between the two rings 0 2 mm thick steel shims are used to ensure the position is correct The 100 diameter spindle hub projects 1 7 mm from its seat 2 x 0 2 mm thick steel rings are to be fitted on the 83 diameter where the crown is mounted Summing up the two rings and the projection we have 2 1 mm The bronze ring is to be housed in the projecting part of the spindle being 2 mm leaving 0 1 mm with respect to the two steel rings If the spindle projects less than 1 7 it will be necessary to add one or two 0 2 mm steel rings to reach MONSTER AG TT Technical assistance manual 9 2 1 mm with a tolerance of 0 0 1 mm the contrary if it projects more than 1 7 then remove both the 0 2 mm rings The measurement to be guaranteed is 2 1 mm with a tolerance of 0 0 1 mm When this measurement is guaranteed the 3 mm steel ring is to be inserted on the 83 diameter By resting against the 0 2 mm rings there will be an 0 1 mm clearance with respect to the bronze ring Then add another two 0 2 mm rings Insert the two tabs in the housings on the spindle hub and fit the crown Once mounted check with a ruler that the crown hub is on the same level as the edge of the gear unit box If the hub projects with respect to the edg
44. ine its component parts and the available functions CHAP 4 This chapter gives a detailed explana tion of how to access and use the service pro grammes The service programmes are auxiliary programmes intended only for technical assist ance personnel and studied to facilitate installa tion maintenance and troubleshooting CHAP 5 The machine s calibration procedure is described in this chapter CHAP 6 The advance stopping calibration procedure is described in this chapter CHAP 7 The procedure for setting global bead breaker disc tangent correction is described here CHAP 8 The procedure for setting tool tangent correction is described here CHAP 9 This chapterexplains howto programme the laser sensor CHAP 10 The purpose of this chapter is to il lustrate in detail the electronic boards on the machine describing the function of the main components the meaning of the warning lights connections and so on CHAP 11 All the information about the ma chine s electrical system is given in this chapter including the protection devices fuses and circuit breakers The wiring diagrams and physical layout of the system are enclosed CHAP 12 All the adjustments to be made the electromechanical and electronic parts of the machine are described in this chapter e g proximity sensors and micro switches CHAP 13 This chapter is dedicated to trou bleshooting CHAP 14 The gloss
45. ine performs upon the direct command ofthe operator without the use of any automatism These controls remain active even if there are alarm conditions that preclude the use of the automatic commands Manual controls are always the hands on type Automatic controls are commands that are partly or completely based on the machine s automatisms If there is a failure with the machine s sensors the automatic controls are disabled and the error codes are displayed Automatic controls can be the hands on type or NOT hands on type 3 2 Control types Based on the operating device used joystick push buttons levers pedals etc the controls can be of the following types Hands on the workeris required to operate the control device continuously all the time that particular action is called for on the machine Manual NOT hands on Using the lever selector 5 16 Three speeds in the clockwise direction of which one for grooving two speeds in the anticlockwise direction The automatic hands on controls can be aborted at any time even intervalled by manual con trols or they can be cancelled before they have finished NOT hands on the worker is NOT required to operate the control device continuously it will suffice to operate it for a moment to start an automatic procedure In some cases the auto matic procedure starts when the push button is released The NON hands on automatic controls can be cancelled at an
46. ing the electrical system and the electronic control board are mounted in different points There are 7 fuses on the CPU RX2 board and 2 1 fuses in the electrical board Table 11 1 lists all the fuses showing their position electrical properties and functions Table 11 1 Position and properties of the fuses on the machine FUSE Self restoring fuse Reference ground GND AGND This fuse protects the CPU RX2 board from short circuits on the control console or its connecting cable internal or external part of the electrical board No replacement is required to restore the fuse remove the cause for the short circuit Self restoring fuse Reference ground GND AGND This fuse protects the CPU RX2 board from short circuits on the CPU RX2 board display board or its connecting cable No replacement is required to restore the fuse remove the cause for the short circuit CPU RX2 board Self restoring fuse Reference ground GND AGND This fuse protects the CPU RX2 board from short circuits on the CPU RX2 board radio modem or its connecting cable No replacement is required to restore the fuse remove the cause for the short circuit Self restoring fuse Reference ground GND AGND This fuse protects the CPU RX2 board from short circuits on the CPU RX2 board F4 external analog sensors or in their connecting cables Noreplacement is required to restore the fuse remove the cause for the short circuit
47. ioning test The RX ON LED white on the electrical board must blink when commands via radio are received 7 If the functioning test is positive close the two radio modems otherwise check you have selected the same channel on both radio modems and reconnected the battery on the TX unit Table E 5 Selecting the radio channel on the radio modems 4 way dip switch a E Pa Pox pa pa on on on on OFF OFF OFF OFF OFF 10 5 Radio modem TX unit The TX radio modem receives the serial flow of data via cable 10 pole flat cable with TTL electrical levels from the CPU TX board located on the control console and transmits them via radio to the homologous RX unit located on the machine s control panel The TX radio modem can only transmit data via radio and not receive via radio The same considerations for the RX radio modem apply to the TX radio modem including selection of the radio channel which in this case is a transmission and not receiving channel 46 MONSTER AG TT Technical assistance manual 10 6 Electronic transmission board CPU TX The electronic transmission board CPU TX is inside the control console and its function is to detect the commands sent by the operator via the push buttons joysticks or pedal unit to serialise them and then to send them via radio modem or cable to the machine to be actuated The CPU TX board has a double power supply
48. ions Bead Breaker Disc Tangent Automatic hands on Uses the potentiometer to work Immediate Bead Breaker Automatic NOT hands on Uses the potentiometer to Disc Tangent work It is started automatically straight after a diameter has been selected with the keys on the control panel This function can be cancelled but not aborted Tool Tangent Automatic hands on Uses the potentiometer and the SQ3 micro switch to work Side To Side Automatic NOT hands on Uses the laser SQ4 micro switch for working and the proximity switch This function can be cancelled but not aborted Leva la Leva Without Lever Automatic hands on Uses the potentiometer and the SQ3 micro switch to work This function can be cancelled and or aborted 24 MONSTER AG TT Technical assistance manual Function Remarks Type of command Return from Leva la Leva Without Lever Automatic hands on Uses the potentiometer and the SQ3 micro switch to work This function can be cancelled and or aborted Double hydraulic unit speed Manual hands on With push button SB2 Limited to right or left transla tion movement of the tool holder arm and with tempo rary reverse movement of the turntable clamp carriage Selecting the rotation speed of the turntable clamp 3 1 Function types The available functions can be performed with either manual or automatic controls Manual controls are those the mach
49. it comes up against no obstacles in a following phase the turntable clamp unit will move on its own so there will be no need to guarantee there are no mechanical interferences 4 Turn the machine off open the electrical board and put dip switch 4 on the electronic control board ON no other dip switch must be ON 5 Turn the machine back on dip4 appears blinking on the display 6 Put dip switch 4 OFF CAF will now appear for two seconds on the display 7 Then the following will appear each for one second AFdn followed by a numerical value that stands for the extent of the advance stop ping ofthe downward radial movement and also AFup again followed by a numerical value that stands for the extent of the advance stopping of the upward radial movement MONSTER AG TT Technical assistance manual 31 8 At this stage the message GO appears on the display blinking which means the machine is asking confirmation to start the procedure Turn the machine off if you do not want to continue otherwise press and release the F key on the control panel CAUTION Before confirming the procedure make sure there is noone that can be injured or obstacles that can be damaged or that could any way prevent the machine from automatically moving the turntable clamp unit radially 9 The machine will automatically start aseries of bead breaker disc tangents fora wheel diameter of 22 5 To abor
50. ity to the structure so it can absorb rebounds Loosen the checknut Turn the foot to lift or lower the base Tighten the checknut As a rule with very heavy wheels it is necessary to unscrew the left foot even by several centime tres In the case of very heavy wheels it might be necessary to adjust the feet This eliminates any jolt ing of the rear of the base In the case of very heavy wheels it is advisable to turn the foot one more time The chassis is de signed to absorb jolts due to the heavy weight 20 MONSTER AG TT Technical assistance manual 6 HYDRAULIC CONTROL UNIT 6 1 Replacing the solenoid valve If one or more solenoid valves need replacing the tightening torque of the nuts on the solenoid valve pack tie rods is of great importance If tightening torque is too much there could be friction on valve slides resulting in poor holding of switching The cylinders might not stay in position oil could drain into the tank Loosen the nuts on the tie rods Replace the faulty solenoid valves Pay attention to the right position of the O rings when replacing Tighten the nuts on the tie rods to a torque of 22 25 Nm 6 2 Replacing the hydraulic pump Proceed as described Undo the 2 screws connecting the solenoid valve block to the manifold Take care not to bend the hydraulic pipes when putting the solenoid valve block back Remove the electric motor Remove the manifold Replace the
51. king sure there are no short circuits on the solenoid valve connectors Glass fuse 5x20 mm delayed Fuse FU2 protects the transformer from shorts on the lamp that lights the working area optional or on its connecting cable 51 Line fuses to protect against short circuits The line fuses are the responsibility of the user who has to have a socket fitted with fuses installed by his own electrician The size of the fuses must be chosen based on the power the machine absorbs that can be gleaned from the ID plate affixed on each machine The line fuses blow in the event of short circuits in the electrical system control unit motor and relative control circuits mains filter motor inverter and relative wiring wiring inside the electrical board Protection against overcurrents The circuit breaker protects the hydraulic control unit motor against overcurrents The motor inverter is protected against overcur rents by its own control electronics For this please see the Motor Protection chap ter 11 4 Motor Protection Acircuit breakerinstalled on the electrical system protects the hydraulic control motorin the event of overloads and or overcurrents The circuit breaker must be rated according to the current absorbed by the motor The circuit breaker can be seen in figure 11 4 Calibrating the circuit breaker must be done on the following occasions e When the lift is manufactured in the factory e Each
52. not switch and the Leva la Leva Without Lever command will not work See also the error message on the display in the relative chapter of the electric electronic service manual It is the micro switch that determines the horizontal working position Position A is 160 mm Tolerance allowed 2 mm Adjusting position A between the middle of the ball joint and the cylinder closing flange Remove the protective casing Bring the joint to a distance of 160 mm by manu ally operating cylinder stroke Position the cam symmetrically in relation to the micro switch wheel Tighten the locking dowel Fix the micro switch perpendicular to the cam Check that distance A is observed both in open ing and closing of the cylinder If it is not observed in both directions either move the cam slightly or change the position of the micro switch Refit the casing 1 1 1 1 1 1 MONSTER AG TT Technical assistance manual 17 4 2 Replacing the arm or tool arm support When replacing the arm or tool support integrity of the unit mounted must be guaranteed together with the correct clearances Shims are also included with the arm and support parts to help correct assembly 4 2 1 Using the shims on the tool arm support unit There is a mm thick steel washer between the tool arm and support See detail B CK lt DETALL SCALE 4 1 Lh O EN NN
53. o Assiale 51205 S Cuscinetto Radiale 62055 SSN Distanziale Cuscinetto Assiale 51205 lt gt 2 Rondella Acc 2 Dadi Bassi 2 Y S SS e SIS IN gt ES MONSTER Technical assistance manual 11 2 10 Replacing the gear unit box Proceed as described for replacing the gear unit crown In addition Replace the gasket between the box and hub Tighten the 12 screws between the gear unit box and spindle holder hub to 85 Nm Screw the remaining two anchorage points without stretching the box 2 11 Replacing the turntable spindle To remove the spindle it is necessary to remove the pulley casing and the driven pulley the distribu tor the turntable cylinder and the gear unit crown as explained in the relative sections Extract the spindle from its seat Check wear of the DU bushings and replace them if necessary Check the gaskets on the spacer ring between the spindle and its seat and replace them if neces sary Make certain that a 1 mm steel ring is inserted inside the spacer ring Insert the spacer ring in the spindle hub up to the end position Mount the new spindle Move the spindle to the end position using one or two clamps if needed Carry out all the steps explained for mounting the crown paying attention to the correct use of the shims Detail B SUIS _ _ A 2 lt 7 WO YO
54. on the CPU RX2 board In this case replace the fuse after having checked the cause for it blowing 004 D Whensome commandsare given the machine does not execute them and a loud buzzing can be heard coming from the electrical system Turntable clamp rotation is always available however R The solenoids relative to the commands that are not executed could have shorted Unplug the electrical connector of these solenoids and measure their electrical resistance If they have shorted they must be replaced 005 D The machine is only carrying out manual com mands and not the automatic ones although there are no error codes on the display The alarm LED on the side of the electrical system box blinks when automatic commands are required R Probably the control board CPU RX2 failed to recognise the presence of the display even if it is present and working so has consequently disabled the automatic commands Try turning the machine off and on if nothing happens check the connecting cable between the control board and the display If the cable is connected as it should be try replacing the cable then the display board and lastly the control board CPU RX2 006 D When the machine is switched on it often causes the differential circuit breaker on the power supply board to trips R The machine s connection to the electricity mains must include installation upstream of a thermal magnetic circuit breaker and a differen tial ci
55. oosen the ball joint until it is off centre in relation to the check plate pin by 0 5 1 mm This offset must be towards the outside of the plate rotation path both in closing and opening of the cylinder 4 3 Replacing the tool rotation micro switch If the micro has to be replaced it must be removed when servicing the tool carriage Pay attention to howit works as correct operation of the automatisms connected to Side to Side depends on it The micro switch for controlling tool rotation must be squeezed when the hook is facing the turntable and the cylinder is closed MONSTER AG TT Technical assistance manual 19 5 MACHINE ADJUSTMENT 5 1 Adjusting the lifting cylinder with wheel support The secondary lifting cylinder has a wheel support so it can move during translation The tip of the stem is milled for a size 38 spanner for adjusting the wheel support position Loosen the checknut keep the support still and turn the stem depending on the turning direction the support will move away or come closer to the round bar With the cylinder at the end of its stroke both open and closed the wheel support must have a maximum clearance of 1 mm in relation to the round seat in which it slides 5 2 Adjusting the base feet The base is fitted with two adjustable feet They are used to level the machine with respect to the ground on which it is installed The centre part of the base is 10 mm off the ground which imparts elastic
56. pump Clean the filter removing all residue Refit the manifold and position the joint Put the electric motor back in place Reposition the solenoid valve block taking care not to dam age the 2 O rings MONSTER AG TT Technical assistance manual 21 Notes 22 MONSTER Technical assistance manual ELECTRONIC ELECTRIC PART 1 INTENDED USE This technical manual is intended for people who install provide assistance and service the automatic heavy duty tyre changers Consequently this manual is not intended for the end customer Some information in this manual is to be consid ered confidential and therefore not to be dis closed in any shape or form to third persons The manual must be read in its entirety with maximum attention some of the operations described are potentially dangerous e g the service programmes and are to be done only by adequately trained personnel This manual is to be used together with the Operating and Maintenance manual it does not replace it that gives other information tables and diagrams essential to understand how the machine works and therefore perform technical assistance jobs in conditions of maximum safety for one s self and for others 2 HOW THE MANUAL IS STRUCTURED This manual is structured in the following way CHAP 3 This chapter describes the overall structure of the mach
57. rcuit breaker with tripping characteristics as recommended in the ELECTRICAL CONNEC TIONS chapterin the Operating and Maintenance manual 007 D 8 8 8 8 is always on the display Sometimes the machine works sometimes it doesn t R This could be due to two completely differ ent reasons a the CPU RX2 board is malfunctioning so is not sending any data to the display which with no data enters its self test mode turning on all the segments and dots In this case however the machine is blocked because the electronic control board is malfunctioning In this case the only solution is to replace the CPU RX2 board b the CPU RX2 boards sends data to the display which fail to arrive at destination so the display enters its self test mode anyway In this case the machine executes all the manual commands but notthe automatic ones because not receiving the data the display does not respond to confirm reception and therefore as far as the electronic control board is concerned the display is not present The most likely cause for this failure is a defect with the cable connecting the display to the electronic control board Note the same indication can be caused by partial failures with the display board or CPU RX2 board possible but unlikely MONSTER AG TT Technical assistance manual 61 14 GLOSSARY Circuit breaker device that protects against overcurrent It is used on this machine to protect the motor of
58. rd s internal logic supply voltage 5V stabilised Protection fuse F7 on the CPU RX2 board LD38 Power supply 20V Green Ground GND AGND This LED indicates the presence of the supply voltage of the logic and analog parts external to the board 20 1V stabilised Protection fuse F7 on the CPU RX2 board Note the four power supply LEDs LD35 LD36 LD37 and LD38 must be on all the time the ma chine is on If the measurement is taken connecting to another ground the resulting values will have no mean ing 40 MONSTER AG TT Technical assistance manual Test point The test points on the CPU RX2 board shown in table 10 2 are for measuring the voltage Table 10 2 Description of the test points on the CPU RX2 board REF VOLTAGE Comment and or reference value 1 30V Voltage DC 30V not stabilised Reference ground GND30 GND30 Ground GND30 TP3 24V Voltage DC 24V stabilised Reference ground GND30 TP4 5V Voltage DC 5V stabilised Reference ground GND AGND GND AGND Ground GND AGND TP6 VA Voltage DC VA not stabilised Reference ground GND AGND Voltages 30V and 24V share the GND30 ground Voltages 5V and 20V share the GND AGND grounds The grounds GND30 and GND AGND are not in common To measure voltage connect the negative test lead of the multimeter to its reference ground these are given in table 10 2 If the measurement is taken connecting to another ground the res
59. requent Questions This chapter lists possible malfunctions in the shape of questions An answer is given for each one with the possible cause and remedy 001 D The machine only works at first speed and never turns off at the end of the commands R Maybe the emergency switch QS2 has been activated it is on the left of the electrical board Check if this switch is in position 1 It should Automatic command s which turn on and off many electrovalves in a sequence determined by the electronics Commands that do not turn on off electrovalves normally be in position 0 In addition if you are carrying out a Side To Side procedure with the switch QS2 on 1 the operation will be aborted as soon as translation starts and error code E11 will be displayed 60 MONSTER AG TT Technical assistance manual 002 When the turntable clamp is turning in the anticlockwise direction it is impossible to have the lowest speed grooving speed whereas it is possible in clockwise rotation R This is perfectly normal grooving speed is only available with clockwise rotation 003 D The machine is not moving anymore even turning it off and then on again but rotation of the turntable clamp is still possible Maybe the circuit breaker has tripped cutting power to the hydraulic unit motor If this happens reset the circuit breaker chapter 11 4 1 Alternatively fuse F5 could have blown 10 A blade type which is
60. rew again Repeat the steps described above tightening half a turn at a time 16 MONSTER AG TT Technical assistance manual 3 3 Replacing a sliding block unit Here are some tips if the whole sliding block unit has to be replaced Loosen all the sliding block screws and ease the Carriage out Remove the old sliding block Pre assemble the six screws on the carriage Use new washers and nuts With the sliding block in position turn the adjust ment screw and open the mobile part Turn the adjustment screw two complete turns in the opposite direction The mobile part will close slightly Look at the enclosed pictures to under stand the direction in which the screw tightens Fit the carriage on the sliding plate Position the carriage in the middle of the sliding plate with the aid ofa 2 5 mm shim placed between the carriage and the fixed part of the slide This has to be done on both sides of the carriage Adjust the width Adjust the height 1 1 1 1 1 One way to see if the sliding blocks are adjusted correctly is to see at what minimum pressure the car riages move By lowering the control unit pressure movements should be between 30 and 40 bar 4 TOOL CARRIAGE 4 1 Adjusting tool position The new Leva la Leva Without Lever device is the combined action between tool rotation and moving back of the turntable unit If the tool is not in position A as shown in the figure the micro switch will
61. t on another machine When a different electronic buffer board is installed the buffer board is near the poten tiometer When the potentiometer is replaced e g for repairs When the potentiometer s mechanical system is removed and or replaced steel wire retainers the potentiometer s supporting plate etc When there are malfunctions on the machine because the potentiometer is no longer cali brated The calibration procedure has priority over all the other calibrations and software corrections available and must always be done first The newelectronic control boards are supplied without calibration data The machine will refuse all attempts to use the automatic functions and the error code E00 will be displayed 5 2 How to calibrate Calibrate as follows 1 If there is a wheel the turntable remove it This is recommended but not mandatory Posi tion the turntable carriage in a point where the radial up down displacement movement does not interfere mechanically with other parts of the machine especially the tool holder arm MONSTER AG TT Technical assistance manual 29 2 Turn the machine off open the electrical board and put dip switch 41 ON 3 Turn the machine back on dipl appears blink ing on the display 4 Put dip switch 1 OFF Call will now appear on the display blinking 5 With the joysticks of the control panel move the turntable carriage into the all up radial posi tion and t
62. t the laser s measuring channel is in perfect working order The laser functioning test is to be run on the following occasions When the machine is manufactured in the factory When a new laser is installed When replacing laser wiring 28 MONSTER AG TT Technical assistance manual Whenever any anomalies occur with the Side To Side STS procedure that can be put down to a laser malfunction error code E04 dis played or wrong measurement of the side of the wheel Working of the whole chain is verified with this test laser hardware and programming laser wiring electronic CPU RX2 board During the laser functioning test the machine cannot perform any movements neither in the Manual nor in the Automatic mode To access the laser functioning test proceed as follows 1 Make sure the machine is OFF 2 Turn dip switch 8 ON 3 Turn on the machine dip8 will be shown blinking on the display to remind you that dip switch 8 is ON 4 Turn dip switch 8 OFF The word laser will be displayed for second to remind you that you are in the laser functioning test procedure A numerical number will then be shown on the machine s display ranging from 0 to 1023 which represents the reading of the analogical signal given by the laser Note the value displayed does not represent the target distance in mm but merely the analogical digital conversion value calculated by the CPU RX2 board 5 Mov
63. t the ongoing procedure press any key on the control panel otherwise wait for the procedure to finish 10 When it has finished AFdn and AFup will appear on the display always followed by two numerical values that represent the new advance stopping values These values will be stored in the non volatile memory to be used each time the machine is turned on 7 GLOBAL BEAD BREAKER DISC TANGENT CORRECTION Once calibrated the machine is able to perform all the automatic bead breaker disc tangent func tions correctly However due to tiny mechanical differences between machines the automatic bead breaker disc tangent functions could bring the bead breaker disc too near or too far away from the rim To solve this problem a global bead breaker disc tangent correction procedure is available with which it is possible to fix the tangent point i e the distance between the bead breaker disc and rim deemed optimum NOTE In the software releases before release CG RO 18 the global bead breaker disc tangent correction procedure also acts on the tool moving it away or bringing it up to the rim edge by the same extent fixed for the bead breaker disc 7 1 When to set global bead breaker disc tangent correction Global correction of the bead breaker disc tan gentis notstrictly necessary and must be done in the cases listed below only after having verified that the automatic bead breaker disc tangent functions are not giving op
64. t was used before on another machine When the potentiometer is replaced e g for repairs When the tool is removed and or replaced When the micro switch of a horizontal tool is removed and or replaced SQ3 When the automatic tool tangent functions fail to give satisfactory results tool too near or too far from the rim MONSTER AG TT Technical assistance manual Whatever the case global correction of the tool tangent must be set only after the machine has been calibrated Chapter 5 and made certain that the micro switch has been adjusted correctly Chapter 12 2 8 2 Verifying the need for global correction of the tool tangent To verify the need to set global correction of the tool tangent proceed as follows 1 Turn the machine on and mount a 22 5 metal sheet rim on the turntable 2 Carry out an automatic tool tangent procedure and check the distance between the plastic pad mounted on the tool and the rim if the distance is correct there will be no need to carry out the global tool tangent correction procedure and you can start working straight away with the machine Figure 8 1 gives the nominal tool rim distance values used in the production of the machines Please refer to these values to evaluate the precision of the tangent just performed and the need for global correction 3 If on the other hand the distance is too small ortoo great proceed with setting global correction of the tool descri
65. ted in Table 13 3 Table 13 3 Beeps emitted by the display mg 1 short beep Confirming pressure of the following push None buttons setting deleting memory selecting inches mm 2 short beeps 1 short beep Confirm None 1 long beep The action that was taken was successful 3 short beeps Negation Repeat the action after having The action that was taken was unsuccessful changed the parameter of the or the action required is not allowed machine you are working on or carry out an action that is allowed Continuous slow Special operating mode active Used inthe SERVICE MODE e g intermittence in calibration to call one s at tention to the fact that a special potentially hazardous operating mode is active Luminous acoustic indicator The luminous acoustic indicator which is located on top of a rod next to the electrical board is activated by the machine each time potentially dangerous manual or automatic commands are ex ecuted The indicator has a blinking orange light Besides blinking the indicator emits a high intensity intermittent sound The following commands activate the acoustic luminous indicator Turntable opening closing Turntable lifting lowering Tool arm bead breaker disc lifting lowering Bead breaker disc tangent Tool tangent Side to Side 13 2 Check correct turning on off of the solenoid valves The machine has a set of 17 solenoid valves for actuating
66. tently both acoustically and luminously To have the right operating mode connect the wires as indicated in figure 12 3 Figure 12 3 Connecting the acoustic luminous indicator 26 3 Nem 2 3 2 7 2 5 mm 14 AWG Acoustic power can be adjusted via the trimmer using a small slotted screwdriver the trimmer is inside the body of the indicator as shown in figure 12 4 The indicators installed on the machines are adjusted to the minimum acoustic power 54 MONSTER AG TT Technical assistance manual Figure 12 4 Adjusting the acoustic power of the indicator 13 TROUBLESHOOTING For troubleshooting purposes the first thing that ought to be done is to check the messages and acoustic and luminous indications given by the machine Based on the operating mode the indications given on the display written messages and acoustic signals by three external LEDs and the acoustic luminous indicator can help understand the reason for the malfunctions or faults 13 1 Operating modes and indications The machine has different ways of working and different personnel access levels Moreover during operation three LEDs on the side of the electrical board are used as well as the display that also has a buzzer to indicate the active mode and machine status There is also an acoustic luminous indicator blinking that is activated when potentially dangerous commands are being executed MONSTER AG TT
67. the electronic control board The machine shows the numeri cal value for one second on the display that corresponds to the global correction of the tool tangent that has just been acquired Alternatively it is possible to set the numerical value directly for global correction with the and keys on the control panel limited to values ranging between 128 and 127 and then confirm by pressing In this case however the physical distance between rim and tool will be ignored and the value shown on the display will be stored 7 The machine now goes to the normal operating mode displaying the default diameter 22 5 not blinking Carry out the automatic tool tangent function a few times to check that setting of the global tangent correction has been successful 8 If the rim tool distance is what is wanted the procedure be deemed completed and normal work can be started Otherwise global correction of the tool tangent will need varying again so repeat the procedure from point 1 Once in the setting procedure if key C Clear is pressed on the control panel the global cor rection value of the tool is set directly at value 0 and the procedure finishes writing End on the display for one second However this operation is not mandatory 9 PROGRAMMING THE LASER SENSOR The laser is supplied already programmed by the manufacturer but in the case of necessity it can be re programmed at any time even on the machine
68. the hydraulic control unit Leva la Leva Without Lever automatic pro cedure to extract the bead In this procedure we have asimultaneous movement of the turntable clamp unit and the tool Leva la Leva Without Lever Backwards pro cedure opposite that of Leva la Leva Without Lever that brings the turntable clamp unit and tool back into their initial positions Also in this procedure we have a simultaneous movement of the turntable clamp unit and the tool but reversed Proximity switch inductive type used to count the chain links and therefore know the relative displacement between the tool holder arm and the turntable clamp carriage during the STS procedure Side To Side automatic procedure where by means of the laser signal the machine bypasses the wheel This procedure is abbreviated with the acronym STS STS see Side To Side 62 MONSTER AG TT Technical assistance manual 15 SUMMARY OF MACHINE CALIBRATIONS AND SETTINGS The following figure summarises the service programmes for calibrations to be done on the machine starting with the most important Not all operations are compulsory except for calibration Only the most common cases of application are given in the boxes in the Application column consult the relative chapter to see what all the application cases are OPERATION MONITOR Chap 5 Dip switch 1 ADVANCE STOPPING CALIBRATION Chap 6 Dip switch 4 GLOBAL BEAD BREAKER DISC TANGEN
69. the turntable cylinder Open the turntable completely at maximum pressure Unscrew the M27 nut on top of the rod Close the turntable cylinder completely Remove the casing and the distributor as explained above Unscrew the whole cylinder Screw the new cylinder down Use medium strength Loctite 243 Tightening torque with wrench 500 Nm For assembly repeat the same steps for disassembly but in the reverse order MONSTER TT Technical assistance manual 2 8 Gear unit turntable unit AS Ss Be AA 2 2 2 2 2 2 2 2 2 2 2 2 NN i 7 z Ve E T 1T 1 to 7777 ut SSA L LI n ims Es X 55555 lt lt lt S 1 a mee NG f TAZA 7772 7 22222222224 8 MONSTER Technical assistance manual 2 9 Replacing the gear unit crown Before opening the gear unit box remove the pulley casing and the driven pulley followed by the distributor and turntable cylinder as explained in the relative sections Remove the big cover and the two small ones from the box Remove the locking ring between the crown and spindle hub Unscrew the two nuts under the axial bearings Remove the worm screw Remove the crown Clean the box of grease and replace it with new grease 2 9 1 Use shims when assembling the crown worm screw The axis of the crown must be positioned
70. time the circuit breaker is replaced e g when assistance is given None of the circuit breakers sent as spares are rated and have to be calibrated as indicated in Table 11 2 Table 11 2 Circuit breaker calibration values Voltage Frequency at which the electrical system works Calibration value 400V 50 60Hz Other NOT See Chap voltage and SPECIFIED 11 5 frequency values Resetting the circuit breaker The circuit breaker that protects the hydraulic control unit motor is designed for manual reset ting this means that if it trips it will not reset itself automatically the control knob has to be turned round to position 0 and after wait ing for the motor to cool down turned back to position 1 The circuit breaker trips cutting supply voltage to the hydraulic control unit motor There are no external signals to indicate that the circuit breaker has tripped The electronic control board continues being powered so if manual or automatic commands are given the solenoid valves continue to trigger and all the indicating devices display LEDs acoustic luminous signals indicator lights will continue working normally The turntable clamp will still continue to rotate because the circuit breaker does not pro tect the motor inverter The motor inverter is protected by its own control electronics 11 5 Versions of the machine supplied at 200 208 230 V THREE PHASE To be able to us
71. timum results When the machine is manufactured in the factory Whenanewelectroniccontrol board is installed never calibrated When an electronic control board is installed that was used before on another machine When the potentiometer is replaced e g for repairs Whenthe automatic bead breaker disctangent functions fail to give satisfactory results bead breaker disc too near or too far from the rim Whateverthe case global correction of the bead breaker disc tangent must only be set after the machine has been calibrated Chapter 5 7 2 Verifying the need for global correc tion of the bead breaker disc tangent To verify the need to set global correction of the bead breaker disc tangent proceed as follows 1 Turn the machine on and mount a 22 5 metal sheet rim on the turntable 2 Carry out an automatic bead breaker disc tan gent procedure and check the distance between disc and rim if the distance is correct there will be no need to carry out the global bead breaker disc tangent correction procedure and you can start working straight away with the machine Figure 7 1 gives the nominal bead breaker disc rim distance values used in the production ofthe machines Please referto these values to evaluate the precision of the tangent just performed and the need for global correction 3 If on the other hand the distance is too small or too great proceed with setting global correc tion of the bead
72. to connector X22 supplies an active signal LD34 Digital input LED DIN 4 Red This LED turns on when the sensor connected to connector X23 supplies an active signal LD28 Digital input LED DIN 5 Red This LED turns on when the sensor connected to connector X26 supplies an active signal LD39 Digital input LED DIN 6 Red This LED turns on when the sensor connected to connector X27 supplies an active signal MOTOR INVERTER CONTROL OUTPUT LEDS LD30 Control output Sl of the motor Red inverter This LED turns on when the speed rotation direction control bit S1 of the motor inverter is set LD31 Control output S2 of the motor Red inverter This LED turns on when the speed rotation direction control bit S2 of the motor inverter is set MONSTER AG TT Technical assistance manual 39 DEFINITION Comment and or reference value POWER OUTPUT LEDS LD33 Control output S3 of the motor Red inverter This LED turns on when the speed rotation direction control bit S3 of the motor inverter is set POWER SUPPLY LEDS LD35 Power supply 30V Green Ground GND30 This LED indicates that the solenoid valves are being powered 30V not stabilised Protection fuse F5 on the CPU RX2 board LD36 Power supply 24V Green Ground GND30 This LED indicates that the solenoid valves are powered 24V stabilised Protection fuse F5 on the CPU RX2 board LD37 Power supply 5V Green Ground GND AGND This LED indicates the presence of the boa
73. to 70 Nm the two M10x35 screws to lock the fixed part of the sliding block If you are going to replace the whole sliding unit do not forget to centre the carriage with respect to the sliding plate using a 2 5 mm shim The shim goes between the carriage and the fixed part of the sliding block See also the chapter on replacing a new sliding block 14 MONSTER AG TT Technical assistance manual 3 2 Adjusting the height This is the new adjustment added with these sliding blocks Loosen the four M10x80 screws to release the mobile part and make it adjustable Ensure that the mobile part is actually free to move Turn the adjustment screw to recover clearance Turn the wrench to tighten the sliding block The following pictures help understand how to tighten the mobile part The gt lt arrows by the adjustment screws show the direction in which to turn the screws to recover clearance Be very careful at this stage if the mobile part is not free to move you risk ruining the adjustment screw If you feel resistance do not force the screw you could ruin the thread TOOL CARRIAGE avvita stringi svita stringi svita stringi i avvita stringi MONSTER AG TT Technical assistance manual 15 SPINDLE CARRIAGE svita avvita stringe _ stringe strings TURNTABLE BAR Once adjusted tighten the four M10x80 screws to 70 Nm If there is still clearance you will have to work on the adjustment sc
74. ue 0 and the procedure finishes writing End on the display for one second However this operation is not mandatory 34 8 GLOBAL TOOL TANGENT CORRECTION Once calibrated the machine is able to perform allthe automatictool tangent functions However due to tiny mechanical differences between machines the automatic tool tangent functions could bring the tool too near or too far away from the rim To solve this problem a global tool tangent cor rection procedure is available with which it is possible to fix the tangent point i e the distance between the tool and rim deemed optimum NOTE This procedure is only available starting from the software release CG RO 18 incl In the software releases before release RO 18 the global bead breaker disc tangent correction procedure also acts on the tool moving it away or bringing it up to the rim edge by the same extent fixed for the bead breaker disc Therefore this procedure is not enabled for previous software releases dip switch 3 is not active 8 1 When to set global tool tangent correction Global correction of the tool tangent is not strictly necessary and must be done in the cases listed below only after having verified that the automatic tool tangent functions are not giving optimum results When the machine is manufactured in the factory When anewelectroniccontrol board is installed never calibrated When an electronic control board is installed tha
75. ulting values will have no mean ing MONSTER AG TT Technical assistance manual 41 Connectors The functions of all the connectors on the CPU RX2 board are given in table 10 3 The connectors reference numbers are first grouped by function and then by progressive number Table 10 3 Description of the connectors on the CPU RX2 board DEFINITION Comment and or reference value POWER OUTPUT CONNECTORS Power outputs 12 pole connector Outputs in DC 30V OUT 1 OUT 6 solenoid Common 30V on pins 1 3 5 7 9 11 valves on pin 2 YV2 on pin 4 and so on Power outputs 12 pole connector Outputs in DC 30V OUT 7 OUT 12 solenoid Common 30V on pins 1 3 5 7 9 11 valves YV7 on pin 2 YV8 on pin 4 and so on Power outputs 12 pole connector Outputs in DC 30V OUT 13 OUT 18 solenoid Common 30V on pins 1 3 5 7 9 11 valves YV13 pin 2 8 pin 4 and so on Power outputs 12 pole connector Outputs in DC 30V OUT 19 OUT 24 solenoid Common 30V on pins 1 3 5 7 9 11 valves YV19 on pin 2 YV20 on pin 4 and so on Ground GND30 2 pole connector This connector has both pins connected to GND30 ground and only used on the Radio Update Kits DIGITAL CONTROL OUTPUT CONNECTORS Contactor drive outputs 3 pole connector 25 Vac outputs X6 3 K2 drive output first hydraulic control unit speed X6 2 K1 K3 drive output second hydraulic control unit speed X6 1 common output Acoustic light signal
76. urn on when the relative solenoid valve is powered according to the fol lowing correspondence LD YVI LD2 YV2 LD3 YV3 and so on Figure 13 1 graphically illustrates allthe solenoid valves that must be powered by the various machine commands Generally speaking however the following is true To analyse correct powering of the solenoid valves give any one manual command and see which solenoid valve is powered and what the machine does If for the command given the solenoid valve powered is the one shown in figure 13 1 but the movement of the machine is opposite that indicated by the screen printing then there could be a reversal of the connections on the solenoids of the valves or the hydraulic pipes have been reversed If for the same command the solenoid valve powered is different from the one shown in figure 13 1 then it could be that the connections inside the control console have been reversed or the joysticks and lever switches mounted incorrectly This check is to be repeated for each manual command to ensure correct connection of the solenoid valves and hydraulic pipes MONSTER AG TT Technical assistance manual 59 Figure 13 1 Correspondence of the solenoid valves with the commands Oil return valve Must close every time when any other hydraulic commands is activated manual or automatic Electrovalves driven by manual commands Electrovalves driven by automatic commands note 13 3 F
77. y command on the console to awaken the transmitter and automatically set the communication channel via cable and turn the green LED on Layout diagram of the machine s control console and electrical board Segnalatore di pericolo DISPLAY SGP58 ed CABLE HL4 ed RX HL2 we ed ALARM HL3 RETE HL1 POWER o we 9 seriale di emergenza Emergency serial cable QUADRO ELETTRICO ELECTRIC PLANT Signaling alarm Caricabatterie A Battery charger 1 RADIO MODEM RX All intemo della console Inside the console Pulsante di ARRESTO STOP button RADIO MODEM TX CONSOLE DI COMANDO COMMAND CONSOLE 26 MONSTER AG TT Technical assistance manual Figure 3 3 Position of the sensors on the machine MOTOR INVERTER LASER WIRE POTEN TIOMETER PROXIMITY SWITCH 4 SERVICE PROGRAMMES The software provided with the electronic con trol board includes besides the normal work programme some service programmes intended for technical assistance personnel The service programmes may only be used by technical assistance personnel on the following occasions When installing the machine on the end cus tomer s premises to either calibrate or adjust machine parameters During technical assistance operations and or routine maintenance A service programmes are used with great caution to avoid setting wrong parameters which could cause the machine to malfunction These programmes can b
78. y time but not aborted Figure 3 1 shows the control console a shows the automatic hands on control b the auto matic NON hands on controls and c the manual controls MONSTER AG TT Technical assistance manual 25 Figure 3 1 Layout of the controls on the sole The commandsare given by acontrol console that is physically separate from the machine itisona trolley to give the worker more mobility The commands are recognised by the CPU TX board onthe control console serialised and then sent to the machine via radio or cable Figure 3 2 The serial data are received by the CPU RX2 board that then decodes them and actuates them driving the solenoid valves and the two motors See figures 3 2 and 3 3 to see the machine s dif ferent electrical and electronic parts Transmission is normally by radio but if the batteries are flat or the radio modem fails it is possible to use the emergency serial cable which is provided with the machine it sees to feeding the control console and to guaranteeing transmission of the commands When the emergency serial cable is connected the CABLE LED turns on HL4 green on the side of the electrical board and communication via cable is set automatically If an emergency cable is connected when the transmitter is in stand by i e if no more than 30 seconds have elapsed since the end of the last command the green LED will not turn on However it is enough to give an

Download Pdf Manuals

image

Related Search

Related Contents

Documentation Utilisateur Brailliant avec un lecteur d    絵画を描いてみよう  onlinecomponents.com  BioSIM 9 - User's Manual - Canadian Forest Service  Manejo del salvaescaleras T80 - Lippe Lift  …/… Étudiants salariés  

Copyright © All rights reserved.
Failed to retrieve file