Contents

1. EH amp Stat Spin Express PRIMARY TUBE CENTRIFUGE 2 Minute Spin Plasma for Coag Testing Plasma for Cardiac Markers Serum or Plasma for Stat Chemistry THE EXPRESS 2 WILL CUT TURNAROUN Stat5pin Express Rapid Blood Separation PRIMARY TUBE CENTRIFUGE The StatSpin Express 2 can improve turnaround time and productivity in any lab By placing it next to any analyzer that requires serum or plasma you ll see an immediate improvement in test efficiency and turnaround time Samples are processed as they arrive no need for batching no unproductive time spent waiting for the centrifuge you I have results in minutes For peak workflow several units can actually provide higher throughput than a larger more costly centrifuge StatSpine Express 2 is ideal for e Rapid plasma for coagulation tests e Sample prep for stat chemistry e Cardiac profiles for the ER e Sharp separations for send out e Anywhere rapid serum or plasma is needed ID TIME IN HALF Cut turnaround time in half Improve productivity One study found that a typical hospital laboratory could reduce cardiac profile TAT from about one hour to thirty minutes by switching to plasma separator tubes streamlining sample transport and installing a StatSpin Express in the workstation Evaluation of the StatSpin9 Express primary tube centrifuge for preparation of samples for measurement of cardiac markers on the ACS
2. Updated US Public Health Service Guidelines for the Management of Occupational Exposures to HBV HCV and HIV and Recommendations for Post Exposure Prophylaxis Appendix A and B MMWR 50 RR 11 1 42 June 29 2001 55 003910 001 Rev E 10 StatSpin Warranty StatSpin Inc a Subsidiary of IRIS International Inc warrants that the instruments shall be free from defects in material and or workmanship under normal use and service for the period expiring twelve 12 months from the date of installation provided the purchaser has completed and forwarded to StatSpin the Warranty Registration Card StatSpin will at its discretion repair or replace any unit covered under this warranty returned to StatSpin with shipping costs prepaid Repaired or replaced instruments supplied under this warranty carry only the remaining portion of the original warranty and repairs shall not interrupt or prolong this warranty For warranty terms and conditions outside the United States contact your Authorized StatSpin Distributor No warranty extended by StatSpin shall apply to any instrument that has been damaged due to misuse negligence accident or damage resulting from unauthorized repairs alterations or improper installation StatSpin makes no warranty other than the one set forth herein This warranty is given expressly in lieu of all other warranties expressed or implied The purchaser agrees that there is no warranty of merchantability or of fitness for
3. any intended purpose and that there are no other remedies or warranties expressed or implied which extend beyond the description on the face of the agreement No agent or employee of StatSpin is authorized to extend any other warranty or assume for StatSpin any liability except as set forth above This warranty is only applicable to the original purchaser Limitation of Liability StatSpin shall not be liable for any loss of use revenue or anticipated profits or for any consequential or incidental damages resulting from the sale or use of the products The purchaser shall be deemed liable for any and all claims losses or damages incurred by the use or misuse of the StatSpin instrument by the purchaser its employees or others following receipt of the instrument or other items 11 STATSPIN EXPRESS 2 CENTRIFUGE GASKET KIT MODEL M501 22 O1 002543 001 NUT DRIVER m m INSERTS a Fi ic RDGA COVER ASSEMBLY 01 008494 001 54 004385 007
4. 1809 System Bayer Corp Diagnostic Division Walpole MA AACC 99 Abstract 277 High quality results for coag or chemistry The Express 2 can produce serum or plasma equal to tubes spun for 7 10 minutes in conventional clinical centrifuges Gel barrier tubes are separated rapidly with minimal barrier distortion Processed tubes can be used on automatic sampling equipment without contaminating the sample probe The Chart shows data on the ability of the Express to produce quality plasma from PST tubes for testing chemistry analytes A full report of this chemistry testing as well as a detailed independent report on platelet count is available upon request Fast Rapid acceleration and dynamic braking reduce waiting for routine blood separations Spins in 2 or 3 minutes Accurate Microprocessor control maintains speed and time to within 5 Compact Takes less than 7 inches 18cm of bench space fits almost any work area or instrument cart Quiet Generates only about 60dB of noise won t disturb nearby workers Safe Cover interlock system chamber gasket and proven mechanical containment for operator safety UL Listed U S Canada CE marked Simple Load tubes and press start preprogrammed cycles simplify run time selection Easy to Maintain 10 bleach compatible surfaces and polypropylene rotor make cleaning easy Disposable chamber liners available for added efficiency Self diagnostics error code lights help reduc
5. 2 has no on off switch and therefore is normally left plugged in and on Unloading 1 Upon completion of the cycle the rotor decelerates to a complete stop in 25 seconds and the latch interlock automatically unlocks 2 Squeeze the black latch pieces together to open cover 3 Carefully remove tubes using care not to re suspend the sediment Overview Section Maintenance StatSpin recommends that instrument operators perform periodic inspections and preventative maintenance on all StatSpin instruments Contact StatSpin s customer service department or distributor if at any time the instrument is not functioning properly Cleaning CAUTION Unplug the Express 2 from the wall outlet before performing maintenance WARNING Do not expose Express 2 and its rotor to strong or concentrated acids bases esters aromatic or halogenated hydrocarbons ketones or strong oxidizing agents The Express 2 is supplied with a disposable bowl liner to simplify routine cleaning Additional bowl liners are available Product No DLO1 The liner should be replaced monthly or whenever a spill occurs Clean the outside surfaces and switch overlay panel with a water dampened cloth and mild detergent Clean the inner surface or bowl with a mild detergent and if necessary a disinfectant wiping surfaces with a dampened cloth using 70 alcohol or 10 bleach solution General Cleaning Rotor Disinfecting eer Or dS Ro es DUPLO IG S C
6. AUTION DO NOT spray the bowl or outer surfaces with detergent or bleach Excess liquid will harm the electronics and subsequent problems may not be covered under warranty Open centrifuge cover Unplug the power supply from the electrical outlet Remove all tubes and inserts Remove the rotor see Removing and Installing the Rotor Remove the black gasket surrounding the chamber by pulling up one end of the gasket Remove the bowl liner and dispose Install a new bowl liner Replace the black gasket around the chamber opening Reinstall rotor see Removing and Installing the Rotor Plug in the power supply Open centrifuge cover Unplug the power supply from the electrical outlet Remove all tubes and inserts Remove the rotor see Removing and Installing the Rotor The rotor and inserts may be soaked in detergent and warm water or a 10 bleach solution DO NOT attempt to clean an insert that has a broken tube Dispose of insert immediately Dry the rotor and inserts with a clean absorbent paper towel or allow to air dry Re install the rotor see Removing and Installing the Rotor Checking the Rotor Speed Service The rated speeds 5 can be checked with a photoelectric tachometer available from many sources If the Express 2 fails to achieve operating speed 8500 rom 5 contact your distributor or StatSpin Customer Service department There are no user serviceable parts Refer all service to qualified service personnel Re
7. acility Appendix A Specifications Product No Model No Speeds Force Cycles Acceleration Time Deceleration Time Electrical Dimensions Environmental Appendix SSX2 M501 22 8500 rom 250 4440 xg 30s 30 seconds 120s 120 seconds 180s 180 seconds Approximately 20 seconds Approximately 25 seconds 24 Volts DC 1 7 amp Includes switching power supply for 100 240 VAC 50 60 Hz Diameter 6 6 16 8 cm Height 6 0 15 2 cm Weight 5 1bs 2 3 kg Indoor use Altitude up to 2000m Temperature 5 C to 40 C Maximum relative humidity 80 for temperatures up to 31 C decreasing linearly to 50 relative humidity at 40 C Main supply voltage fluctuations not to exceed 10 of the nominal voltage Transient over voltages according to installation category II Pollution degree 2 Stat 5pim A Subsidiary of IRIS International Inc Norwood MA 02062 USA Phone 800 782 8774 or 781 551 0100 Fax 781 551 0036 www statspin com EC REP mdi Europa GmbH Wittekamp 30 D 30163 Hanover Germany 49 511 39089530 C c Made in USA References 1 NCCLS Protection of Laboratory Workers from Occupationally Acquired Infections Approved Guideline Second Edition NCCLS document M29 A2 ISBN 1 56238 453 8 NCCLS 940 West Valley Rd Suite 1400 Wayne Pennsylvania 19087 1898 USA 2001 2 CDC Recommendations for prevention of HIV transmission in health care settings MMWR Suppl No 2S 2S 18S 1987 3 CDC
8. e chance of operator error and aid in instrument trouble shooting Chemistry Plasma StatSpin Express 2 Beckman Centrifuge 8500 rpm 3000 rpm 2 MINUTES 10 MINUTES Marker Mean Range Mean Range Potassium 4 04 3 3 4 7 4 05 3 3 4 7 AST 21 6 12 52 Zh 12 52 ALT 16 0 3 38 16 0 3 36 LDH 134 68 205 137 209 24 Duplicate Samples in PST Tubes Plasma Separator Analyzed in a Beckman CX 7 Stat Spint Express sentes Statspin Express 2 Reg includes a remote M E s gu P universal power Aa off any single phase electrical power from 100 240V The power supply has an IEC 320 receptacle so virtually any standard computer type power cord can be used Specifications Speed Force e 8500 rpm 4440 xg 250 Quick Spin 30 seconds Cycle Time Normal 120 seconds Hard Spin 180 seconds Acceleration Time 20 seconds to 95 of speed Deceleration Time e Accepts up to 5 mL blood tubes 13 x 75 mm Tube Accommodation Monovette syringe tubes and smaller tube formats see ordering information 100 to 240V 50 60 Hz 1 7 amp Remote power supply has a 50 cm 3 5 ft line to the centrifuge and a 5 ft North American power cord Replacement AC power cord must have an IEC 320 connector and meet lt HAR gt standard Power Requirements Dimensions Hx wx D Weight e 15 2 x 16 8 x 21 9 cm 6 0 In x 6 6 In x 8 6 In 2 3 kg 5 Ibs Specification subject to change w
9. e EMIL URL E EUN DIE 9 Appendix A Specifications seessssseeee eene nennen 9 IGIerencas ooodeaxx pedi E dri epee pa M Md Em be Ma EE 10 StatSpin Warranty sociae ueiducuad E OEE 11 How to use this manual This manual along with information contained on product labels and in package inserts should provide you with all the information you need to operate and maintain the Express 2 Notes appear in italics to highlight information When the information requires special attention a caution symbol appears next to the italicized text Please pay close attention to the instructions that accompany the notes and symbols as well as the standard laboratory practices outlined by your facility and local regulatory agencies The table below lists all the CAUTIONS WARNINGS for the Express 2 WARNING North American Installation Only use the power supply included with the unit Use of other power supplies or transformers will damage the Express 2 electronics and void the warranty WARNING Outside of North America Do Not Use the Line Cord Supplied Use power cord for at least 1 0 Amp or more with an IEC320 CEE22 female connector and male connector suitable for the power outlet to be used CAUTION The cover interlock bypass is designed for emergency use only If the equipment is not used properly safety may be impaired CAUTION The rotor RTX4 has a finite lifespan that is dependant on usage Cracks or swelling that develop indicat
10. e only If the equipment is not used properly safety may be compromised Removing and Installing the Rotor The Express 2 is shipped with the rotor installed To prevent possible damage to the centrifuge s motor mount it is important to remove the rotor whenever the centrifuge is moved or shipped to another location CAUTION The rotor RTX4 has a finite lifespan that is dependant on usage Cracks or swelling are signs of fatigue replace immediately 1 Remove the tube inserts from the rotor 2 Remove rotor locking nut and washer from the rotor holder using 7 16 nut driver 3 Gently rock the rotor back and forth until the mounting pins on the rotor holder release 4 Remove the rotor To re install rotor 1 Remove the tube inserts from rotor Place rotor on rotor holder ensuring the two mounting pins on the rotor holder are aligned with two of the four small holes near the center of the rotor 2 Gently rock the rotor back and forth to ensure the rotor seats properly on the rotor holder 3 Install washer then nut and secure the rotor by tightening the nut with the 7 16 nut driver provided 4 Re install the tube inserts into the rotor cavities The centrifuge is now ready for use CAUTION Failure to properly install the rotor may result in damage to the centrifuge and will void the warranty Spinning the Sample Loading CAUTION Never operate the Express 2 without the rotor in place 1 Ensure the appropriate t
11. e the rotor should be replaced immediately CAUTION Failure to properly install the rotor may result in damage to the centrifuge and will void the warranty CAUTION Never operate the Express 2 without the rotor in place CAUTION Replace balance tube every 10 cycles to prevent possible breakage due to the repeated stress of centrifugation CAUTION Unplug the Express 2 from the wall outlet before performing maintenance WARNING Do not expose Express 2 and its rotor to strong or concentrated acids bases esters aromatic or halogenated hydrocarbons ketones or strong oxidizing agents CAUTION DO NOT spray the bowl or outer surfaces with detergent or bleach Excess liquid will harm the electronics and subsequent problems may not be covered under warranty CAUTION Universal Precautions should be followed on all specimens regardless of whether a specimen is known to contain an infectious agent See references Please use the system as intended Improper use of the Express 2 Primary Tube Centrifuge and or its accessories may cause damage to the system inaccurate results or potentially nullify warranties The Express 2 Primary Tube Centrifuge and its associated components are covered under US patent nos 4 846 974 amp 4 981 585 amp 5 566 919 Section Al Unpacking and Installation Inspect Packaging The Express 2 and its accessories are delivered in one carton If the centrifuge or accessories have suff
12. east 1 0 Amp or more with an IEC320 CEE22 female connector and male connector suitable for the power outlet to be used Principle and Intended Use Section 2 System Overview For in vitro diagnostic use for rapid separation of whole blood contained in original collection tubes IVD The Express 2 is a microprocessor controlled high speed bench top centrifuge designed to rapidly separate blood in the original evacuated or syringe type collection tubes The four place 30 angle rotor included with the centrifuge is designed to provide rapid separation while minimizing potential re suspension of cells The speed is fixed at 8500 rpm 250 rpm producing a centrifugal force of 4440 xg at the maximum tube radius of 5 5 cm The operator may select three factory set timed cycles each cycle spinning for 30 120 and 180 seconds Symbols and Definitions Start button Stop open button Cycle selector Error Service indicator 00O Power input 2 8 0 24V 1 7A The start button initiates a pre timed cycle at the speed selected NOTE The Express 2 does not have an on off switch and is normally left plugged in and k 5 on The stop open button interrupts the cycle and stops the centrifugation This button may also be used to release the cover This button allows for selection of the appropriate cycle The red LED identified as error service is illuminated continuously or flashing when service is r
13. equired DC Power Input 24V DC Plug in Symbols and Definitions cont Product Reference Indicates the StatSpin product catalog number Number Caution Statement of caution warning read instruction carefully Temperature Indicates storage requirements range limitation EC Representative European Community Authorized Representative REP IVD For in vitro Clarifies for use as in vitro diagnostic only diagnostic use 2 Non sterile Indicates non sterile product Serial Number Indicates instrument serial number code i Consult Consult instruction manual or insert sheet for further Instructions explanation Error Indicators Error codes for the Express 2 are specified by a combination of the Error Service LED flashing or continuous and any combination of the cycle LEDs on the front panel Error Service I Quick Spin 30 s Normal Spin 120 s Hard Spin 180 s M a SOE308 Rotor failed 20s Cover opened il to reach rpm i i ue 120 within 30 s INS changed during Error Service a ane operation light flashing 180s 120s or continous 30s pai e Insufficient CASS Rotor spun 120s Sikes to 120s backward maintain ie direction during ie i rpm ZOHas0s reverse braking mou e ENN Error Service light will continuously illuminate when the centrifuge has achieved a total cycle count of 18 000 which is the useful life of the drive system Drive mechanism needs replacing Contact an authorized service center Access
14. ered any damage in transport please inform your carrier immediately NOTE Save shipping carton and components to simplify return should service be required Verify Contents The package contains One Express 2 centrifuge Model No M501 22 One Centrifuge Rotor Product No RTX4 Four Rotor Inserts for 13x75 mm tubes Product No SV01 One Universal Switching Power Supply StatSpin Product No 01 3553 001 APS Product No AD 740U 1240 One grounded line cord for North American use only One Operator s Manual One Tool for Removing Rotor 7 16 Nut Driver Install System 1 Place the Express 2 on a level surface suitable for laboratory instrumentation 2 Maintain a 300mm clearance boundary around the centrifuge for ventilation and safety 3 Position the Express 2 away from direct sunlight and sources of heat or cold See Appendix A for specifications 4 Remove blue foam packaging around the rotor before operating the centrifuge Connect Power Plug the power supply into a grounded outlet supplying the voltage and frequency indicated on the power supply When power is connected the 30 s LED will illuminate and the cover lock will release WARNING North American Installation Only use the power supply included with the unit Use of other power supplies or transformers will damage the Express 2 electronics and void the warranty WARNING Outside of North America Do Not Use the Line Cord Supplied Use power cord for at l
15. ference the StatSpin Warranty for further instruction Be sure to complete and return the warranty card as directed Decontamination before returning for service Any instrument or accessory containing accumulated blood and or other biological or chemical deposits must be cleaned prior to shipment to the manufacturer dealer for service This decontamination is required by Federal Law Title 48 and 49 of the Federal Regulations and in accordance with the Environmental Protection Agency s Regulations for Biohazard Waste Management StatSpin personnel cannot perform this decontamination Troubleshooting No Power Light l Is the power cord completely gt NO Plug power cord into the wall plugged into the wall i YES L Is the wall outlet working properly gt NO gt Try another wall outlet Is the barrel connector from the gt NO gt Plug the barrel connector into the centrifuge transformer completely plugged into the centrifuge i YES I Contact StatSpin or an Authorized Repair Facility Centrifuge Will Not Spin Shuts Off Prematurely l Is the cover completely closed and gt NO Completely close the cover cannot be opened manually YES L Contact StatSpin or an Authorized Repair Facility Centrifuge will not open at end of cycle 4 Is the bowl gasket completely gt NO gt Press the bowl gasket all the way down into seated and sealing the bowl the housing slot YES i Contact StatSpin or an Authorized Repair F
16. ithout prior notice The StatSpin Express drive and suspension system are covered under U S Patent No 5 566 919 StatSpin is a registered trademark of StatSpin Inc Monovette is a trademark of Sarstedt Inc StatSpin Express 2 for 100 240V 50 60 Hz Includes 4 place rotor RTX4 universal power supply removable chamber liner four 5 mL Inserts and North American power cord Inserts for 5 mL Tubes 13 x 75 mm 4 pk Included with centrifuge VO2 Inserts for 3 mL Tubes 10 25 x 64 mm 4 pk Inserts for 2 mL Tubes 10 25 x 47 mm or BD Microtainers 4 pk V04 Inserts for 1 5 2 mL Microtubes e g LipoClear 4 pk DLO1 Disposable Chamber Liners 10k RTX4 Replacement Express 2 Rotor Includes four SVO1 Inserts pu CE A Division of Iris International Inc The 24V line to the centrifuge includes a locking nut for secure installation li Sample Processing 60 Glacier Drive Westwood MA 02090 Tel 781 551 0100 Fax 781 551 0036 800 782 8774 www proiris com 64 003929 001 Rev C Express 2 Primary Tube Centrifuge Operator s Manual Stat 5pim Operator s Manual Express 2 Primary Tube Centrifuge Model Number M501 22 FOR IN VITRO DIAGNOSTIC USE Product Number SSX2 Express 2 for 100 240 VAC 50 60 Hz StatSpin is a registered trademark of StatSpin Inc a Subsidiary of IRIS International Inc Copyright 2001 2003 Printed in U S A Table of Contents How fo use this manhldl scoc
17. ories Product No Description SV01 Inserts for 5 mL tubes 13 x 75 mm or 10 25 x 82 mm 4 pk Included with centrifuge SV02 Inserts for 3 mL tubes 10 25 x 64 mm 4 pk SV03 Inserts for 2 mL tubes 10 25 x 47 mm or BD Microtainers 4 pk SV04 Inserts for 1 5 2 mL Microtubes e g LipoClear 4 pk DLO1 Disposable chamber liners 10 pk RTXA Express 2 Rotor Includes four SVO1 inserts Section 3 Operating Instructions Opening and Closing the Cover The system s electrically operated cover interlock mechanism prevents operation until the cover is completely closed and latched and prevents the cover from being opened while the rotor is turning When the cover is completely closed and locked an operating cycle can be initiated The system is also equipped with a manually operated latch that holds the cover down after spinning is complete The interlock is automatically released at the end of the operating cycle or by pushing the stop open button Squeeze the black latch pieces together to open cover Cover Interlock By pass The electronically operated cover interlock mechanism can be released manually by inserting the straightened end of a large paper clip or similar object into the small hole in the center of the front membrane panel Manually push the lock lever inward about one inch 25mm to release the interlock mechanism if the stop open button does not release the cover CAUTION The cover interlock bypass is designed for emergency us
18. sees sess cascccesecscdenvcesausevecendenssesnunesaceaceasnoosanescceaceasvevsectaccsedens ii DOCUON a P 1 Unpacking and Installation oie estt ccs e etos o aaro ener Rea bano ERE CHR SERE ea RR a eee PER eus EE Eds 1 MVS CCU Pac ACN otedcst SNERRE ENES vs serait pace acne dde ente sauteed beta vectes OET eene l VVC ONEN ar T AAA l AS CAN VS E E A A ET E A E A l CONNECUPOWE gee oktan al hel f les het a AE an l Id Mee A E O He 2 System OV GIVI OW x tei ste cede hese dec need Er EE AECE 2 Principle and Intended Use 1 2 Symbols and Definitions seeessssssssssseenennnnnnnnnnnnnnnnnnnes 2 EITOPTDOIedlO S siia MD E oe ae NONE Ot ge LAM I EE 3 AGERE SSO f 21 gt nee ee E eee LED E M M MEO RUE eee ee 3 SST ET aa I Fr I pod EURO 4 Operating Instructions 0 0 c ccc cece eee eee e eee e eee Imm nnns 4 Opening and Closing the Cover ssssssssssssIR n es 4 Removing and Installing the Rotor ssssssss 4 SPINNING the Sample eene mener 5 vi ieldfo E epe uU 6 Mailtenal6B uon ovettesdah Ups o bxdut T pato ebradRud eae aa alma anne 6 SI o o 6 CIeSnilleseceehoietcu IMMER ere 6 Checking the Rotor Speed ssssssssseseennnnes 7 vlc 7 TFOUDIESKOO WING NNI RUE 8 ADDOBOD assis teat ate tans tee ERI MERE UM I ened aad MEE Mese d M p E SL c
19. ube inserts are installed The Express 2 centrifuge is provided with four tube inserts for 13 x 75 mm tubes Product No SV01 Other sizes are available See accessories 2 Two or four tubes may be processed at one time The rotor must be properly balanced to ensure smooth operation 3 Use the same size and style tubes in opposite positions Balance liquid in tubes to within 0 5 mL CAUTION Replace balance tube every 10 cycles to prevent possible breakage due to repeated stress of centrifugation 4 Close and latch the centrifuge cover 5 Select the appropriate cycle by pressing the cycle selector until the desired LED is illuminated See Table 1 6 Press start button Table 1 Express 2 Cycle Settings The operator should experiment with different settings to achieve optimum performance for specific applications The following are general guidelines Setting Speed Time 30s Intended to provide a short spin 8500 rpm 30 seconds to immediately separate the red cells from the plasma serum 120s Intended to produce good 8500 rpm 120 seconds quality plasma serum from whole blood for chemistry or coagulation 180s Intended to provide a minimal 8500 rpm 180 seconds particle cell count and should be used for specialized applications e g Lipoclear The normal spin 120 s can be used for most chemistry and coagulation applications The hard spin 180 s can be used for gel separator tubes PST SST NOTE The Express