SPARC Enterprise T5440 Server Service Manual
Contents
1. Commands cd show 26 Controlling How POST Runs The server can be configured for normal extensive or no POST execution You can also control the level of tests that run the amount of POST output that is displayed and which reset events trigger POST by using ILOM command variables The keyswitch_state parameter when set to diag overrides all the other ILOM POST variables TABLE ILOM Parameters Used for POST Configuration on page 26 lists the ILOM variables used to configure POST FIGURE Flowchart of Variables for POST Configuration on page 20 shows how the variables work together TABLE ILOM Parameters Used for POST Configuration Parameter Values Description keyswitch_mode normal The system can power on and run POST based on the other parameter settings For details see FIGURE Flowchart of Variables for POST Configuration on page 20 This parameter overrides all other commands diag The system runs POST based on predetermined settings stby The system cannot power on locked The system can power on and run POST but no flash updates can be made diag_mode off POST does not run normal Runs POST according to diag_level value service Runs POST with preset values for diag_level and diag_verbosity diag_level max If diag_mode normal runs all the minimum tests plus extensive processor and memory tests min If diag_mode normal runs minimum set of tests SPARC Enterprise T5440 Serve
2. e Fast blink System received a signal as a result of one of the methods previously mentioned indicating that it is active Service If on indicates that service is required POST and ILOM are two diagnostics Required LED tools that can detect a fault or failure resulting in this indication amber The ILOM show faulty command provides details about any faults that cause this indicator to light Under some fault conditions individual component fault LEDs are lit in addition to the system Service Required LED Power OK LED Provides the following indications green e Off Indicates that the system is not running in its normal state System power might be off The service processor might be running e Steady on Indicates that the system is powered on and is running in its normal operating state No service actions are required e Fast blink Indicates the system is running at a minimum level in standby and is ready to be quickly returned to full function The service processor is running e Slow blink Indicates that a normal transitory activity is taking place Slow blinking could indicate the system diagnostics are running or that the system is booting Related Information m Rear Panel Diagram on page 5 m Ethernet Port LEDs on page 8 m Detecting Faults Using LEDs on page 30 Identifying Server Components 7 Ethernet Port LEDs The service processor network management port and t
3. NNN 2 gt Dram Error AFAR channel 2 00000000 00000000 2 gt L2 AFAR channel 2 00000000 00000000 Perform further investigation if needed m If POST detects a faulty device the fault is displayed and the fault information is passed to the service processor for fault handling Faulty FRUs are identified in fault messages using t he FRU name m The fault is captured by the service processor where the fault is logged the Service Required LED is lit and the faulty component is disabled See CODE EXAMPLE Fault Detected by POST on page 48 m Run the ILOM show In this example SYS MI faulty command to obtain additional fault information B CPU0 CMP0 BR1 CHO DO is disabled The system can boot using memory that was not disabled until the faulty component is replaced Note You can use ASR commands to display and control disabled components See Disabling Faulty Components on page 50 Related Information m Diagnostic Flowchart on page 11 Managing Faults 43 a POST Fault Management Overview on page 19 a POST Fault Management Flowchart on page 20 a SPARC Enterprise T5440 Server Administration Guide Identifying Faults Detected by PSH When a PSH fault is detected a Solaris console message similar to CODE EXAMPLE Console Message Showing Fault Detected by PSH on page 44 is displayed CODE EXAMPLE Console Message Showing Fault Detected by PSH SUNW MSG ID
4. on page 150 Connect the Power Cords to the Server on page 153 Power On the Server on page 153 Servicing the Front I O Board The front I O board contains two USB connectors You must remove the front control panel to service the front I O board 146 SPARC Enterprise T5440 Server Service Manual July 2009 Related Information Infrastructure Boards and Cables on page 1 Front Panel Diagram on page 3 Servicing the Front Control Panel on page 144 Remove the Front I O Board Before you begin complete these tasks Read the section Safety Information on page 59 Power off the server using one of the methods described in the section Powering Off the System on page 63 Disconnect Power Cords From the Server on page 65 Remove the Server From the Rack on page 67 Perform Electrostatic Discharge Antistatic Prevention Measures on page 69 Remove the Top Cover on page 69 Remove a Fan Tray on page 83 Remove the Fan Tray Carriage on page 129 Unplug the front control panel cable from J9901 on the motherboard Unplug the front control panel cable from the front I O board Remove the two No 2 Phillips screws Servicing Field Replaceable Units 147 FIGURE Removing the Front I O Board 4 5 Lift the front I O board up and out of the system Place the front I O board on an antistatic mat V Install the Front I O Board 1 2 3
5. FIGURE Network Management Connector Diagram lt e e gt NET MGT TABLE Network Management Connector Signals Pin Signal Description Pin Signal Description 1 Transmit Data 5 Common Mode Termination 2 Transmit Data 6 Receive Data 3 Receive Data 7 Common Mode Termination 4 Common Mode Termination 8 Common Mode Termination Serial Port Connector Pinouts The serial port connector TTYA is a DB 9 connector that can be accessed from the back panel FIGURE Serial Port Connector Diagram 12345 oo COW o 6789 TABLE Serial Port Connector Signals Pin Signal Description Pin Signal Description 1 Data Carrier Detect 6 Data Set Ready 2 Receive Data 7 Request to Send 3 Transmit Data 8 Clear to Send 4 Data Terminal Ready 9 Ring Indicate 5 Ground Connector Pinouts 169 USB Connector Pinouts Two Universal Serial Bus USB ports are located on the motherboard in a double stacked layout and can be accessed from the back panel Two additional USB ports are located on the front panel FIGURE USB Connector Diagram TABLE USB Connector Signals Pin Signal Description Pin Signal Description Al 5 V fused Bl 5 V fused A2 USBO 1 B2 USB2 3 A3 USB0 1 B3 USB2 3 A4 Ground B4 Ground Gigabit Ethernet Connector Pinouts Four RJ 45 Gigabit Ethernet connectors NETO NET1 NET2 NET3 are lo
6. Isolate and replace the faulty FRU in the External 1 O Expansion Unit Identify and replace the faulty FRU from the PSH message and perform the procedure to clear the PSH detected fault faulty FRU from the POST Identify and replace the message and perform the procedure to clear the POST detected faults Managing Faults 11 TABLE Diagnostic Flowchart Actions Action No Diagnostic Action Resulting Action For more information 1 Check Power OK The Power OK LED is located on the front and rear Detecting Faults on and AC Present of the chassis page 30 LEDs on the server The AC Present LED is located on the rear of the server on each power supply If these LEDs are not on check the power source and power connections to the server 2 Run the ILOM The show faulty command displays the following Detect Faults Using the show faulty kinds of faults ILOM show faulty command to check e Environmental faults Command on page 33 for faults e External I O Expansion Unit faults e Solaris Predictive Self Healing PSH detected faults e POST detected faults Faulty FRUs are identified in fault messages using the FRU name Note If the ILOM show faulty output includes an error string such as Ext sensor or Ext FRU it indicates a fault in the External I O Expansion Unit 3 Check the Solaris The Solaris log files and the ILOM system event log Detecting Faults Us
7. Servicing Customer Replaceable Units 93 Vv Install a PCIe Card 1 Identify the correct slot for installation 2 Open the PCIe card latch FIGURE Installing a PCIe Card 3 4 Insert the PCIe card into its slot Close the PCIe card latch Next Steps Install the Top Cover on page 150 Slide the Server Into the Rack on page 151 Power On the Server on page 153 Y Add a PCIe Card Before you begin complete these tasks Read the section Safety Information on page 59 Power off the server using one of the methods described in the section Powering Off the System on page 63 Disconnect Power Cords From the Server on page 65 Extend the Server to the Maintenance Position on page 66 94 SPARC Enterprise T5440 Server Service Manual July 2009 m Perform Electrostatic Discharge Antistatic Prevention Measures on page 69 m Remove the Top Cover on page 69 1 Identify the correct slot for installation See PCIe Device Identifiers on page 96 and PCIe Slot Configuration Guidelines on page 97 2 Open the PCIe card latch 3 Remove the PCIe filler panel gt Insert the PCIe card into its slot FIGURE Installing a PCIe Card 5 Close the PCIe card latch Next Steps m Install the Top Cover on page 150 m Slide the Server Into the Rack on page 151 m Power On the Server on page 153 Servicing Customer Repla
8. autres pays Fujitsu et le logo Fujitsu sont des marques d pos es de Fujitsu Limited Toutes les marques SPARC sont utilis es sous licence et sont des marques de fabrique ou des marques d pos es de SPARC International Inc aux Etats Unis et dans d autres pays Les produits portant les marques SPARC sont bas s sur une architecture d velopp e par Sun Microsystems Inc SPARC64 est une marques d pos e de SPARC International Inc utilis e sous le permis par Fujitsu Microelectronics Inc et Fujitsu Limited SSH est une marque d pos e registre de SSH Communications Security aux Etats Uniset dans certaines autres juridictions L interface d utilisation graphique OPEN LOOK et Sun a t eusen Nae par Sun Microsystems Inc pour ses utilisateurs et licenci s Sun reconna t les efforts de pionniers de Xerox pour la recherche et le d veloppement du concept des interfaces d utilisation visuelle ou graphique pour l industrie de l informatique Sun d tient une license non exclusive de Xerox sur l interface d utilisation graphique Xerox cette licence couvrant galement les licenci s de Sun qui mettent en place l interface d utilisation graphique OPEN LOOK et qui en outre se conforment aux licences crites de Sun Droits du gouvernement am ricain logiciel commercial Les utilisateurs du gouvernement am ricain sont soumis aux contrats de licence standard de Sun Microsystems Inc et de Fujitsu Limited ainsi qu aux clauses appli
9. Front Panel Diagram The server front panel contains a recessed system power button system status and fault LEDs Locator button and LED The front panel also provides access to internal hard drives the DVD ROM drive if equipped and the two front USB ports FIGURE Front Panel Features on page 3 shows front panel features on the SPARC Enterprise T5440 server For a detailed description of front panel controls and LEDs see Front Panel LEDs on page 4 FIGURE Front Panel Features ann A OM oO o ommo Figure Legend 1 Locator Button LED 5 Component Fault LEDs 2 Service Required LED 6 DVD ROM Drive 3 Power OK LED 7 USB Ports 4 Power Button 8 Hard Drives Related Information m Front Panel LEDs on page 4 Identifying Server Components 3 m Rear Panel Diagram on page 5 m Servicing the Front Bezel on page 115 Front Panel LEDs See TABLE Rear Panel System LEDs on page 7 for a description of the front panel system LEDs and controls TABLE Front Panel LEDs and Controls LED or Button Icon Description Locator LED The Locator LED enables you to find a particular system The LED is activated and button using one of the following methods white e The ALOM CMT command setlocator on e The ILOM command set SYS LOCATE value Fast_Blink e Manually press the Locator button to toggle the Locator LED on or off This LED provides the following indications e Off Normal oper
10. Host System keyswitch_state Normal product_name T5440 product_serial_number 0723BBC006 fault_state OK clear_fault_action none power_state On Commands cd reset set show start stop Powering Off the System Note Additional information about powering off the system is located in the SPARC Enterprise T5440 Server Administration Guide Related Information m Power Off From the Command Line on page 64 m Power Off Graceful Shutdown on page 64 m Power Off Emergency Shutdown on page 65 Preparing to Service the System 63 V Power Off From the Command Line 1 Shut down the Solaris OS At the Solaris prompt type shutdown g0 i0 y svc startd The system is coming down Please wait svc startd 91 system services are now being stopped Jun 12 19 46 57 wgs41 58 syslogd going down on signal 15 svc stard The system is down syncing file systems done Program terminated r eboot o k prompt h alt 2 Switch from the system console prompt to the service processor console prompt Type ok gt 3 From the ILOM gt prompt type gt stop SYS Are you sure you want to stop SYS y n y Stopping SYS Note To perform an immediate shutdown use the stop force script SYS command Ensure that all data is saved before entering this command YV Power Off Graceful Shutdown Press and release the Power button If n
11. a Hard Drive LEDs on page 80 m Server Components on page 173 Remove a Hard Drive Hot Plug Removing a hard drive from the server is a three step process You must first identify the drive you want to remove unconfigure that drive from the server and then manually remove the drive from the chassis Note See Hard Drive Device Identifiers on page 79 for information about identifying hard drives Before you begin complete these tasks m Read the section Safety Information on page 59 Servicing Customer Replaceable Units 73 1 At the Solaris prompt issue the cfgadm al command to list all drives in the device tree including drives that are not configured Type cfgadm al This command should identify the Ap_id for the hard drive you wish to remove as in CODE EXAMPLE Sample Ap_id Output on page 75 2 Issue the cfgadm c unconfigure command to unconfigure the disk For example type cfgadm c unconfigure c0 dsk ditid1l where c0 dsk c0t1d1 is the disk that you are trying to unconfigure 3 Wait until the blue Ready to Remove LED lights This LED will help you identify which drive is unconfigured and can be removed 4 On the drive you plan to remove push the hard drive release button to open the latch FIGURE Removing a Hard Drive on page 74 FIGURE Removing a Hard Drive Caution The latch is not an ejector Do not bend the latch too far Doing so
12. amber O TOP FAN REAR PS The recessed Power button toggles the system on or off If the system is powered off press once to power on e If the system is powered on press once to initiate a graceful system shutdown e If the system is powered on press and hold for 4 seconds to initiate an emergency shutdown For more information about powering on and powering off the system see the SPARC Enterprise T5440 Server Administration Guide Provides the following operational fan indications e Off Indicates a steady state no service action is required e Steady on Indicates that a fan failure event has been acknowledged and a service action is required on at least one of the fan modules Provides the following operational PSU indications e Off Indicates a steady state no service action is required e Steady on Indicates that a power supply failure event has been acknowledged and a service action is required on at least one PSU Provides the following operational temperature indications e Off Indicates a steady state no service action is required e Steady on Indicates that a temperature failure event has been acknowledged and a service action is required Related Information m Front Panel Diagram on page 3 m Rear Panel LEDs on page 7 m Detecting Faults Using LEDs on page 30 Rear Panel Diagram The rear panel provides access to system I O ports PCle ports Gigabi
13. command to determine when the host has been powered off The console will display status Powered Off Servicing Customer Replaceable Units 107 c Switch to the system console to view POST output gt start SYS console Watch the POST output for possible fault messages The following output is a sign that POST did not detect any faults 0 0 gt INFO 0 0 gt POST Passed all devices 0 0 gt POST Return to VBSC 0 0 gt Master set ACK for vbsc runpost command and spin ooo o Note Depending on the configuration of ILOM POST variables and whether POST detected faults or not the system might boot or the system might remain at the ok prompt If the system is at the ok prompt type boot d Return the virtual keyswitch to Normal mode gt set SYS keyswitch_state Normal Set ketswitch_state to Normal e Switch to the system console and issue the Solaris OS fmadm faulty command fmadm faulty No memory faults should be displayed If faults are reported refer to the diagnostics flowchart in FIGURE Diagnostic Flowchart on page 11 for an approach to diagnose the fault 4 Switch to the ILOM command shell 5 Run the show faulty command m If the fault was detected by the host and the fault information persists the output will be similar to the following example gt show faulty Target Property Value eee ee ee sea cape ee ee a ee eee ee e
14. gt ALOM compatibility shell sc gt OpenBoot PROM firmware ok Conventions for Alert Messages This manual uses the following conventions to show alert messages which are intended to prevent injury to the user or bystanders as well as property damage and important messages that are useful to the user Warning This indicates a hazardous situation that could result in death or serious personal injury potential hazard if the user does not perform the procedure correctly Caution This indicates a hazardous situation that could result in minor or moderate personal injury if the user does not perform the procedure correctly This signal also indicates that damage to the product or other property may occur if the user does not perform the procedure correctly Caution This indicates that surfaces are hot and might cause personal injury if touched Avoid contact xviii SPARC Enterprise T5440 Server Service Manual July 2009 Caution This indicates that hazardous voltages are present To reduce the risk of electric shock and danger to personal health follow the instructions Tip This indicates information that could help the user to use the product more effectively Alert Messages in the Text An alert message in the text consists of a signal indicating an alert level followed by an alert statement A space of one line precedes and follows an alert statement Caution The following task
15. m Front control panel m Front I O board Related Information m Servicing Fan Trays on page 81 m Servicing the Hard Drive Backplane on page 132 m Servicing the Motherboard on page 135 m Servicing the Front Control Panel on page 144 m Servicing the Front I O Board on page 146 Remove the Fan Tray Carriage Before you begin complete these tasks m Read the section Safety Information on page 59 m Power off the server using one of the methods described in the section Powering Off the System on page 63 m Extend the Server to the Maintenance Position on page 66 m Perform Electrostatic Discharge Antistatic Prevention Measures on page 69 m Remove a Fan Tray on page 83 Note You must remove all four fan trays m Remove the Top Cover on page 69 m Remove a CMP Memory Module on page 99 Note You must remove all CPU modules and memory modules from the system Do the following Servicing Field Replaceable Units 129 1 Remove the nine No 1 Phillips screws securing the fan tray carriage to the top of the chassis FIGURE Removing the Fan Tray Carriage 2 Loosen the seven captive No 2 Phillips securing the bottom of the fan tray carriage to the motherboard assembly 3 Lift the fan tray carriage up and out of the system V Install the Fan Tray Carriage 1 Lower the fan tray carriage into the system 130 SPARC Enterprise T5
16. on page 165 Performing Node Reconfiguration 157 Reconfiguring I O Device Nodes You might need to change the connection between the CMP modules and the onboard devices described in TABLE Devices controlled by CMPs in 2P systems on page 164 or TABLE Devices controlled by CMPs in 4P systems on page 165 in one of the following circumstances a A CMP module has completely failed you need access to a PCIe slot or device which was attached to that CMP module and you are unable to temporarily replace the failed module or move an existing module over from a different slot until the failed CMP is replaced m You are upgrading from a 2P to a 4P system Related Information m Managing Faults on page 9 m I O Connections to CMP Memory Modules on page 156 a System Bus Topology on page 162 m I O Fabric in 2P Configuration on page 164 m I O Fabric in 4P Configuration on page 165 ma Temporarily Disable All Memory Modules on page 160 m Reconfigure the I O and PCIe Fabric on page 158 a Re Enable All Memory Modules on page 161 m Reset the LDoms Guest Configuration on page 162 Vv Reconfigure the I O and PCIe Fabric The reconf p1 script reconfigures the PCIe fabric to reconnect the PCIe slots and onboard devices to the CMP nodes as efficiently as possible The reconf p1 script also reconfigures the Solaris device names to match the new connections between the CMP modules and the PCIe device
17. v Obtain the Chassis Serial Number Remotely 62 Powering Off the System 63 v Power Off From the Command Line 64 v Power Off Graceful Shutdown 64 v Power Off Emergency Shutdown 65 v Disconnect Power Cords From the Server 65 Extending the Server to the Maintenance Position 65 v Extend the Server to the Maintenance Position 66 Removing the Server From the Rack 67 v Remove the Server From the Rack 67 Contents vii Performing Electrostatic Discharge Antistatic Prevention Measures 69 v Perform Electrostatic Discharge Antistatic Prevention Measures 69 Removing the Top Cover 69 v Remove the Top Cover 69 Servicing Customer Replaceable Units 71 Hot Pluggable and Hot Swappable Devices 72 Servicing Hard Drives 72 v Remove a Hard Drive Hot Plug 73 v Install a Hard Drive Hot Plug 75 v Remove a Hard Drive 77 v Installa Hard Drive 78 Hard Drive Device Identifiers 79 Hard Drive LEDs 80 Servicing Fan Trays 81 v Remove a Fan Tray Hot Swap 81 v Installa Fan Tray Hot Swap 82 v Remove a Fan Tray 83 v Installa Fan Tray 84 Fan Tray Device Identifiers 84 Fan Tray Fault LED 84 Servicing Power Supplies 85 v Remove a Power Supply Hot Swap 86 v Install a Power Supply Hot Swap 87 v Remove a Power Supply 89 v Installa Power Supply 90 Power Supply Device Identifiers 91 Power Supply LED 91 Servicing PCIe Cards 92 viii SPARC Enterprise T5440 Server Service Manual July 2009 v RemoveaPCle Card 93 v Installa PCIe Card 94 v Add
18. 4 Lower the front I O board into the system Install the two No 2 Phillips screws Plug the front control panel connector into the front I O board Plug the front control panel connector into J9901 on the motherboard Next Steps Install the Fan Tray Carriage on page 131 Install a Fan Tray on page 84 Install the Top Cover on page 150 Install the Server Into the Rack on page 150 Connect the Power Cords to the Server on page 153 Power On the Server on page 153 148 SPARC Enterprise T5440 Server Service Manual July 2009 Returning the Server to Operation These topics describe how to return the SPARC Enterprise T5440 and SPARC Enterprise T5440 servers to operation after you have performed service procedures Caution Never attempt to run the server with the cover removed Hazardous voltage is present Caution Equipment damage could occur if you run the server with the cover removed The cover must be in place for proper air flow Topic Links Install the top cover after servicing internal Install the Top Cover on page 150 components Re attach the server to the cabinet slide rails Install the Server Into the Rack on after performing a bench procedure page 150 Slide the server back into the equipment Slide the Server Into the Rack on page 151 rack Re attach power cords and data cables to the Connect the Power Cords to the Server on back
19. EVENT TIME nformation EC ACTION SUN4V 8000 DX TYPE Fault VER 1 SEVERITY Minor Wed Sep 14 10 09 46 EDT 2005 PLATFORM SUNW system_name CSN HOSTNAME wgs48 37 SOURCE cpumem diagnosis REV 1 5 EVENT ID 92e9fbe 735e c218 cf87 9e1720a28004 DESC The number of errors associated with this memory module has exceeded acceptable levels Refer to http sun com msg SUN4V 8000 DX for more i A UTO RESPONSE Pages of memory associated with this memory module are being removed from service as errors are reported IMPACT Total system memory capacity will be reduced as pages are retired R Schedule a repair procedure to replace the affected memory module Use fmdump v u lt EVENT_ID gt to identify the module Faults detected by the Solaris PSH facility are also reported through service processor alerts Note You can configure ILOM to generate SNMP traps or e mail alerts when a fault is detected by Solaris PSH You can also configure the ALOM CMT compatibility shell to display Solaris PSH alerts See the Integrated Lights Out Manager 3 0 Concepts Guide CODE EXAMPLE ALOM CMT Alert of PSH Diagnosed Fault on page 44 depicts an ALOM CMT alert of the same fault reported by Solaris PSH in CODE EXAMPLE Console Message Showing Fault Detected by PSH on page 44 CODE EXAMPLE ALOM CMT Alert of PSH Diagnosed Fault SC Alert Host detected fault MSGID SUN4V 8000 Dx The ILOM sho
20. FRU device names for the fan trays in the server TABLE Fan Tray Device Identifiers Device Device Identifier FTO SYS MB FTO FT1 SYS MB FT1 FT2 SYS MB FT2 FT3 SYS MB FT3 Related Information m Managing Faults on page 9 a Hot Pluggable and Hot Swappable Devices on page 72 m Fan Tray Fault LED on page 84 Fan Tray Fault LED Each fan tray contains a Fault LED that is located on the top panel of the server The LED is visible when you slide the server partially out of the rack 84 SPARC Enterprise T5440 Server Service Manual July 2009 See TABLE Fan Tray Fault LED on page 85 for a description of fan tray Fault LED and its function TABLE Fan Tray Fault LED LED Color Notes Fault Amber This LED is lit when the fan tray is faulty The front panel Fan Fault LED and the front and rear panel Service Required LEDs are also lit if the system detects a fan tray fault In addition the system Overtemp LED might be lit if a fan fault causes an increase in system operating temperature See Front Panel LEDs on page 4 and Rear Panel LEDs on page 7 for more information about system status LEDs Related Information Managing Faults on page 9 Hot Pluggable and Hot Swappable Devices on page 72 m Fan Tray Fault LED on page 84 Servicing Power Supplies The server is equipped with redundant hot swappable power supplies Redundant power supplies enable you to remove
21. ILOM 15 triggered by power supply fault 92 set command and component_state property 48 setkeyswitch parameter 28 55 56 107 setlocator command 4 7 55 66 show faulty command 31 43 55 and faults detected by POST 35 and PSH faults 34 and Service Required LED 32 description and examples 32 environmental fault 34 reasons to use 33 use in detecting faults in an External I O Expansion Unit 35 using to check for faults 12 using to diagnose FB DIMMs 106 using to verify successful FB DIMM replacement 108 showcomponent command 24 51 showenvironment command 55 showfaults command syntax 55 showfru command 25 56 showkeyswitch command 56 showlocator command 56 showlogs command 56 showplatform command 56 62 shutdown triggered by top cover removal emergency shutdown 150 using Power button emergency shutdown 5 using Power button graceful shutdown 5 using powercycle command graceful shutdown 54 using powercycle f command emergency shutdown 54 using poweroff command 54 slide rail latch 66 Solaris log files 12 Solaris log files as diagnostic tool 12 Solaris OS checking log files for fault information 12 collecting diagnostic information from 35 message buffer checking 36 message log files viewing 36 Solaris Predictive Self Healing 17 SunVTS 18 as fault diagnosis tool 12 browser environment 40 Component Stress parameter 40 exercising the system with 38 software packages 41 Syst
22. O Fabric in 2P Configuration on page 164 Performing Node Reconfiguration 165 166 SPARC Enterprise T5440 Server Service Manual July 2009 Connector Pinouts This section provides reference information about the system back panel ports and pin assignments Topic Links Reference for system Serial Management Port Connector Pinouts on page 167 connector pinouts Network Management Port Connector Pinouts on page 168 Serial Port Connector Pinouts on page 169 USB Connector Pinouts on page 169 Gigabit Ethernet Connector Pinouts on page 170 Related Information m Identifying Server Components on page 1 Serial Management Port Connector Pinouts The serial management connector labeled SERIAL MGT is an RJ 45 connector located on the back panel This port is the default connection to the system console 167 FIGURE Serial Management Connector Diagram SERIAL MGT TABLE Serial Management Connector Signals Pin Signal Description Pin Signal Description 1 Request to Send 5 Ground 2 Data Terminal Ready 6 Receive Data 3 Transmit Data 7 Data Set Ready 4 Ground 8 Clear to Send 168 Network Management Port Connector Pinouts The network management connector labeled NET MGT is an RJ 45 connector located on the motherboard and can be accessed from the back panel This port needs to be configured prior to use SPARC Enterprise T5440 Server Service Manual July 2009
23. Panel on page 144 m Servicing the Front I O Board on page 146 178 SPARC Enterprise T5440 Server Service Manual July 2009 Index Numerics 3 3V standby power supply rail 2 A AC Present power supply LED 12 92 adding CMP memory module 101 FB DIMMs 109 PCIe card 94 addresses device and system configuration 156 advanced ECC technology 21 Advanced Lights Out Management ALOM CMT connecting to 22 airflow blocked 13 antistatic wrist strap 61 ASR blacklist 51 52 asrkeys system components 24 Automatic System Recovery ASR 50 B battery installing 125 removing 125 blacklist ASR 51 bootmode command 54 break command 53 Cc cfgadm command 74 76 77 chassis dimensions 1 serial number 62 clearfault command 53 clearing POST detected faults 48 clearing PSH detected faults 49 CMP fault recovery 160 CMP module disabling to run system in degraded state 160 failure recovery 157 fault recovery 155 I O devices connected to 156 CMP memory module 100 adding 101 device identifiers 103 installing 100 removing 99 supported configurations 104 CMP memory modules supported configurations 104 CMP0 failure mode 156 CMP1 failure mode 156 command cfgadm 74 76 77 disablecomponent 52 fmdump 45 iostat E 77 removefru 55 setlocator 4 7 55 66 show faulty 32 108 showfaults 55 showfru 25 56 component_state ILOM component property 48 components disabled autom
24. Product Notes are available on the website only Please check for the recent update on your product xvi SPARC Enterprise T5440 Server Service Manual July 2009 UNIX Commands This document might not contain information on basic UNIX commands and procedures such as shutting down the system booting the system and configuring devices Refer to the following for this information m Software documentation that you received with your system m Solaris Operating System documentation which is at http doces sun com Text Conventions Typeface Meaning Examples AaBbCc123 and directories on screen computer output AaBbCc123 What you type when contrasted with on screen computer output AaBbCc123 Book titles new words or terms words to be emphasized Replace command line variables with real names or values The names of commands files Edit your login file Use 1s a to list all files You have mail o 6 su Password Read Chapter 6 in the User s Guide These are called class options To delete a file type rm filename The settings on your browser might differ from these settings Preface xvii Prompt Notations The following prompt notations are used in this manual Shell Prompt Notations C shell C shell superuser machine name machine name Bourne shell and Korn shell Bourne shell and Korn shell superuser ILOM service processor
25. Server Safety and Compliance Guide SPARC Enterprise PRIMEQUEST Common Installation Planning Manual SPARC Enterprise T5440 Server Site Planning Guide SPARC Enterprise T5440 Server Installation and Setup Guide SPARC Enterprise T5440 Server Service Manual SPARC Enterprise T5440 Server Administration Guide Integrated Lights Out Manager 2 0 User s Guide Integrated Lights Out Manager 2 0 Supplement for SPARC Enterprise T5440 Server Minimum steps to power on and boot the server for the first time Information about the latest product updates and issues Safety information that is common to all SPARC Enterprise series servers Safety and compliance information that is specific to the server Requirements and concepts of installation and facility planning for the setup of SPARC Enterprise and PRIMEQUEST Server specifications for site planning Detailed rackmounting cabling power on and configuring information How to run diagnostics to troubleshoot the server and how to remove and replace parts in the server How to perform administrative tasks that are specific to the server Information that is common to all platforms managed by Integrated Lights Out Manager ILOM 2 0 How to use the ILOM 2 0 software on the server C120 E504 C120 E508 C120 E391 C120 E509 C120 H007 C120 H029 C120 E510 C120 E512 C120 E511 C120 E474 C120 E513 Preface XV Title Description Manual C
26. Server Service Manual July 2009 Performing Node Reconfiguration If a CMP memory module pair develops a fault the SPARC Enterprise T5440 can be reconfigured to run in a degraded state until the CMP memory module is replaced In addition you can add CMP memory module pairs to existing systems However adding or removing CMP memory modules might affect internal hardware device addresses as well as the device address of any external devices attached to the system such as external disk arrays and devices attached via an External I O Expansion Unit Depending on which CMP memory module is added or removed it might be necessary to manually reassign one or more I O devices before they can function correctly in the new system configuration Topic Links Learn about how CMP memory modules I O Connections to CMP Memory map to I O devices Modules on page 156 Learn how to reconfigure the server to Reconfiguring I O Device Nodes on temporarily bypass a failed CMP memory page 158 module Disable memory modules Temporarily Disable All Memory Modules on page 160 Reconfigure I O and PCIe fabric Reconfigure the I O and PCIe Fabric on page 158 Re enable memory modules to work in a Re Enable All Memory Modules on new I O and PCle configuration page 161 Reset logical domain guest configuration Reset the LDoms Guest Configuration on page 162 Reference for system bus topology System Bus Topology on
27. Setup Guide m SPARC Enterprise T5440 Server Administration Guide m Integrated Lights Out Manager 3 0 Supplement for SPARC Enterprise T5440 Server Detecting Faults Using ILOM show faulty Command Use the ILOM show faulty command to display the following kinds of faults 32 SPARC Enterprise T5440 Server Service Manual July 2009 m Environmental or configuration faults System configuration faults Or temperature or voltage problems that might be caused by faulty FRUs power supplies fans or blower or by room temperature or blocked air flow to the server m POST detected faults Faults on devices detected by the POST diagnostics m PSH detected faults Faults detected by the Solaris Predictive Self Healing PSH technology m External I O Expansion Unit faults Faults detected in the optional External I O Expansion Unit Use the show faulty command for the following reasons m To see if any faults have been diagnosed in the system m To verify that the replacement of a FRU has cleared the fault and not generated any additional faults Related Information m Diagnostic Flowchart on page 11 m Detecting Faults Using LEDs on page 30 m ILOM to ALOM CMT Command Reference on page 53 m SPARC Enterprise T5440 Server Installation and Setup Guide m SPARC Enterprise T5440 Server Administration Guide m Integrated Lights Out Manager 3 0 Supplement for SPARC Enterprise T5440 Server V Detect Faults Us
28. SunVTS Tests on page 42 lists test categories that are especially useful to run on this server 5 Optional Customize individual tests Click on the name of the test to select and customize individual tests Tip Use the System Excerciser High Stress Mode to test system operations Use the Component Stress High setting for the highest stress possible SPARC Enterprise T5440 Server Service Manual July 2009 6 Start testing Click the Start Tests button Status and error messages appear in the test messages area located across the bottom of the window You can stop testing at any time by clicking the Stop button During testing the SunVTS software logs all status and error messages To view these messages click the Logs tab You can choose to view the following logs m Test Error Detailed error messages from individual tests m SunVTS Test Kernel Vtsk Error Error messages pertaining to the SunVTS software itself Look here if the SunVTS software appears to be acting strangely especially when it starts up m Information Detailed versions of all the status and error messages that appear in the test messages area m Solaris OS Messages var adm messages A file containing messages generated by the operating system and various applications m Test Messages var sunvts logs sunvts info A directory containing the SunVTS log files SunVTS Software Packages TABLE SunVTS Softw
29. Supply LED on page 91 Power Supply LED Each power supply contains a dual color LED that is visible when looking at the back panel of the system See TABLE Power Supply Status LEDs on page 91 for a description of power supply LED modes and their function listed from top to bottom TABLE Power Supply Status LEDs LED State Meaning Notes Off No AC present Power supply is unplugged or if no AC power is present Blinking green AC present system AC power is present and system is in standby in standby mode Servicing Customer Replaceable Units 91 TABLE Power Supply Status LEDs Continued Continued LED State Meaning Notes Green AC present system System is powered on powered on Blinking amber Fault Voltage overcurrent or other power fault Amber Fault Internal power supply failure or power supply fan failure The following LEDs are lit when a power supply fault is detected m Front and rear Service Required LEDs m Rear PS Failure LED on the bezel of the server a Fault LED mode on the faulty power supply The front and rear panel Service Required LEDs are also lit if the system detects a power supply fault See Front Panel LEDs on page 4 and Rear Panel LEDs on page 7 for more information about identifying and interpreting system LEDs See Power Supply LED on page 91 for specific information about power supply status LEDs Related Information m Managing Faults on page 9 Ho
30. Tools Boot reconf pl 10 Run the reconf p1 script Type mnt reconf pl Performing Node Reconfiguration 159 11 Halt the system Type halt 12 Power off the system For example to power off using the ALOM compatibility shell type sc gt poweroff Wait for the console message which indicates that the system has been powered off V Temporarily Disable All Memory Modules A disabled CMP node complicates the memory topology and can prevent a system from booting To run the system in a degraded state you must reduce the total amount of system memory by disabling all of the FB DIMMs on all of the memory modules in order to work around this complication If you are recovering from a failed CMP module you must temporarily disable the FB DIMMS on all memory modules when Solaris is halted and the system is powered off The FB DIMMs are re enabled after the I O and PCle devices are reconfigured You can either physically remove the memory modules from the system or remotely disable all FB DIMMs located on all memory modules using the disablecomponent command To remove the memory modules from the system see the instructions in the SPARC Enterprise T5440 Server Service Manual To remotely disable all FB DIMMs in the system do the following 1 Halt the Solaris OS 2 Power off the system 160 SPARC Enterprise T5440 Server Service Manual July 2009 3 Disable each FB DIMM sc
31. an antistatic mat 2 Ensure that the ejector tabs are in the open position 3 Line up the FB DIMM with the connector Align the FB DIMM notch with the key in the connector This ensures that the FB DIMM is oriented correctly Servicing Customer Replaceable Units 109 4 Push the FB DIMM into the connector until the ejector tabs lock the FB DIMM in place If the FB DIMM does not easily seat into the connector verify that the orientation of the FB DIMM is correct If the orientation is reversed damage to the FB DIMM might occur 5 Repeat Step 2 through Step 4 until all the FB DIMMs are installed Next Steps Install a CMP Memory Module on page 100 Install the Top Cover on page 150 Slide the Server Into the Rack on page 151 Power On the Server on page 153 Supported FB DIMM Configurations Use these FB DIMM configuration rules to help you plan the memory configuration of your server Each CMP memory module pair holds 16 industry standard FB DIMMs 4 FB DIMM slots are located on the CMP module 12 FB DIMM slots are located on the memory module All FB DIMMs in the system must be the same density same capacity At minimum Channel 0 FB DIMM Slot 0 in all branches must be populated In branches populated with more than one FB DIMM for example in 8 and 16 FB DIMM configurations FB DIMMs are addressed in pairs Each pair must be identical same part number A replacement FB DIMM must have the same
32. are installed If you removed an existing hard drive from a slot in the server you must install the replacement drive in the same slot as the drive that was removed 3 Slide the drive into the drive slot until it is fully seated Servicing Customer Replaceable Units 75 FIGURE Installing a Hard Drive 4 Close the latch to lock the drive in place 5 At the Solaris prompt type the cfgadm al command to list all drives in the device tree including any drives that are not configured Type cfgadm al This command should help you identify the Ap_id for the hard drive you installed For an output example refer to CODE EXAMPLE Sample Ap_id Output on page 77 6 Type the cfgadm c configure command to configure the disk For example type cfgadm c configure c0 sdl where c0 sd1 is the disk that you are trying to configure 7 Wait until the blue Ready to Remove LED is no longer lit on the drive that you installed 8 At the Solaris prompt type the cfgadm al command to list all drives in the device tree including any drives that are not configured Type cfgadm al This command should identify the Ap_id for the hard drive that you installed The drive you installed should be is configured 76 SPARC Enterprise T5440 Server Service Manual July 2009 9 Type the iostat E command Type iostat E The iostat E command displays information about your system s installed devic
33. can damage the latch 74 SPARC Enterprise T5440 Server Service Manual July 2009 5 Grasp the latch and pull the drive out of the drive slot CODE EXAMPLE Sample Ap_id Output Ap_id Type Receptacle Occupant Condition co scsi bus connected configured unknown c0 dsk d1t0do disk connected configured unknown c0 dsk d1t1d0 disk connected configured unknown usb0 1 unknown empty unconfigured ok usb0 2 unknown empty unconfigured ok usb0 3 unknown empty unconfigured ok usb1 1 unknown empty unconfigured ok usb1 2 unknown empty unconfigured ok usb1 3 unknown empty unconfigured ok usb2 1 unknown empty unconfigured ok usb2 2 unknown empty unconfigured ok usb2 3 unknown empty unconfigured ok usb2 4 unknown empty unconfigured ok usb2 5 unknown empty unconfigured ok usb2 6 unknown empty unconfigured ok usb2 7 unknown empty unconfigured ok unknown empty unconfigured ok V Install a Hard Drive Hot Plug Installing a hard drive into the SPARC Enterprise T5440 servers is a two step process You must first install a hard drive into the desired drive slot Then you must configure that drive to the server Perform the following process to install a hard drive 1 If necessary remove the blank panel from the chassis Note The server might have up to three blank panels covering unoccupied drive slots 2 Align the replacement drive to the drive slot Hard drives are physically addressed according to the slot in which they
34. for every fault d940ac2 d21e c94a 258 f 8a9bb69d05b m Message identifier which can be used to obtain additional fault information SUN4V 8000 JA m Faulted FRU The information provided in the example includes the part number of the FRU part 541215101 and the serial number of the FRU serial 101083 The Location field provides the name of the FRU In CODE EXAMPLE Output from the fmdump v Command on page 46 the FRU name is MB meaning the motherboard Managing Faults 45 Note fmdump displays the PSH event log Entries remain in the log after the fault has been repaired 2 Use the message ID to obtain more information about this type of fault a In a browser go to the Predictive Self Healing Knowledge Article web site http www sun com msg b Obtain the message ID from the console output or the ILOM show faulty command c Enter the message ID in the SUNW MSG ID field and click Lookup In CODE EXAMPLE PSH Message Output on page 46 the message ID SUN4V 8000 JA provides information for corrective action 3 Follow the suggested actions to repair the fault CODE EXAMPLE Output from the fmdump v Command fmdump v u d940ac2 d21e c94a f 258 f8a9bb69d05b TIME UUID SUNW MSG ID Jul 31 12 47 42 2007 fd940ac2 d21e c94a f258 f8a9bb69d05b SUN4V 8000 JA 100 fault cpu ultraSPARC T2 misc_regs Problem in cpu cpuid 16 serial 5D67334847 Affects cpu cpuid 16 serial 5D67334847 FRU he serial 101
35. gt disablecomponent SYS MB MEMx CMPx BR0 CHO D1 sc gt disablecomponent SYS MB MEMx CMPx BR0O CHO D2 sc gt disablecomponent SYS MB MEMx CMPx BR1 CH1 D3 where x is the memory module to be disabled CODE EXAMPLE Using the disablecomponent command to disable all FB DIMMs on MEM1 on page 161 shows how to disable all the FB DIMMs on MEM1 CODEEXAMPLE Using the disablecomponent command to disable all FB DIMMs on MEM1 sc gt sc gt sc gt sc gt sc gt sc gt sc gt sc gt sc gt sc gt sc gt sc gt disablecomponent disablecomponent disablecomponent disablecomponent disablecomponent disablecomponent disablecomponent disablecomponent disablecomponent disablecomponent disablecomponent disablecomponent SYS MB MEM1 CMP1 BR0 CH0 D1 SYS MB MEM1 CMP1 BR0 CH0 D2 SYS MB MEM1 CMP1 BR0 CH0 D3 SYS MB MEM1 CMP1 BR0 CH1 D1 SYS MB MEM1 CMP1 BR0 CH1 D2 SYS MB MEM1 CMP1 BR0 CH1 D3 SYS MB MEM1 CMP1 BR1 CH0 D1 SYS MB MEM1 CMP1 BR1 CH0 D2 SYS MB MEM1 CMP1 BR1 CH0 D3 SYS MB MEM1 CMP1 BR1 CH1 D1 SYS MB MEM1 CMP1 BR1 CH1 D2 SYS MB MEM1 CMP1 BR1 CH1 D3 YV Re Enable All Memory Modules Now that the connection between the CMP modules and the I O devices has been reestablished you can re enable the FB DIMMS that were temporarily disabled in Temporarily Disable All Memory Modules on page 160 Do one of the following m Install the memory modules if you removed them m Re enable all of the FB DIMMs whi
36. hard drive assemblies circuit boards or PCI cards When servicing or removing server components attach an antistatic strap to your wrist and then to a metal area on the chassis Following this practice equalizes the electrical potentials between you and the server Note An antistatic wrist strap is no longer included in the accessory kit for the SPARC Enterprise T5440 servers However antistatic wrist straps are still included with options Antistatic Mat Place ESD sensitive components such as motherboards memory and other PCBs on an antistatic mat Preparing to Service the System 61 Required Tools The SPARC Enterprise T5440 server can be serviced with the following tools Antistatic wrist strap Antistatic mat No 1 Phillips screwdriver No 2 Phillips screwdriver 7 mm hex driver No 1 flat blade screwdriver battery removal Pen or pencil power on server YV Obtain the Chassis Serial Number To obtain support for your system you need your chassis serial number The chassis serial number is located on a sticker that is on the front of the server and another sticker on the side of the server V Obtain the Chassis Serial Number Remotely Use the ILOM show SYS command to obtain the chassis serial number gt show SYS SYS Targets SERVICE LOCATE ACT PS_FAULT TEMP_FAULT 62 SPARC Enterprise T5440 Server Service Manual July 2009 FAN_FAULT Properties type
37. on reset None all resets all resets diag_verbosity error reset normal N a max max Description of POST This is the default POST POST does not POST runs the full POST runs the full execution configuration This run resulting in spectrum of tests spectrum of tests configuration tests the quick system with the maximum with the maximum system thoroughly and initialization This output displayed output displayed suppresses some of the is not a suggested detailed POST output configuration Related Information a Diagnostic Flowchart on page 11 m Detecting Faults Using LEDs on page 30 m ILOM to ALOM CMT Command Reference on page 53 m SPARC Enterprise T5440 Server Administration Guide m Integrated Lights Out Manager 3 0 Supplement for SPARC Enterprise T5440 Server Managing Faults 57 58 SPARC Enterprise T5440 Server Service Manual July 2009 Preparing to Service the System These topics describe how to prepare the SPARC Enterprise T5440 for servicing Topic Links Observe proper safety practices Gather the tools needed to perform service procedures Obtain the chassis serial number Power off the system Slide the server out of the equipment rack Remove the server from the equipment rack Remove the top cover to access internal components Safety Information on page 59 Required Tools on page 62 Obtain the Chassis Serial Number on page 62 Power
38. operation Remove install and add hard drives Remove and install fan trays Remove and install power supplies Remove install and add PCle cards Remove install and add CMP or memory modules Remove install and add FB DIMMs Exploded views of CRUs Hot Pluggable and Hot Swappable Devices on page 72 Servicing Hard Drives on page 72 Servicing Fan Trays on page 81 Servicing Power Supplies on page 85 Servicing PCle Cards on page 92 Servicing CMP Memory Modules on page 98 Servicing FB DIMMs on page 104 Customer Replaceable Units on page 174 Related Information m Servicing Field Replaceable Units on page 115 71 Hot Pluggable and Hot Swappable Devices Hot pluggable devices are those devices that you can remove and install while the server is running However you must perform administrative tasks before or after installing the hardware for example mounting a hard drive In the SPARC Enterprise T5440 server the following devices are hot pluggable a Hard drives Hot swappable devices are those devices that can be removed and installed while the server is running without affecting the rest of the server s capabilities In the SPARC Enterprise T5440 server the following devices are hot swappable m Fan trays a Power supplies Note The chassis mounted hard drives can be hot swappable depending on how they are configured Related In
39. page 162 Reference for I O fabric in supported I O Fabric in 2P Configuration on page 164 configurations I O Fabric in 4P Configuration on page 165 Related Information m Managing Faults on page 9 155 m Servicing PCle Cards on page 92 m Servicing CMP Memory Modules on page 98 m Servicing FB DIMMs on page 104 I O Connections to CMP Memory Modules Each PCle slot and onboard I O device is connected to one CMP module Device address is dependent on system configuration See TABLE Devices controlled by CMPs in 2P systems on page 164 and TABLE Devices controlled by CMPs in 4P systems on page 165 for more information If a CMP module fails the onboard devices and slots directly connected to it become unavailable Recovery of the I O services connected to the failed CMP requires I O node reconfiguration For example in a 4P system if CMPO goes offline the following devices become unavailable a PCIe0 PClel m Onboard hard drives In this failure scenario the system is unable to boot from internal drives Similarly if CMP1 goes offline the following devices become unavailable m PCle4 a PCle5 m Onboard network devices Related Information m System Bus Topology on page 162 m I O Fabric in 2P Configuration on page 164 a I O Fabric in 4P Configuration on page 165 156 SPARC Enterprise T5440 Server Service Manual July 2009 Recovering from a Failed CMP
40. part number as the other FB DIMM in its pair For example a replacement FB DIMM in J1201 must have the same part number as the FB DIMM in J1401 in order to ensure an identical pair If you are unable to obtain a matching FB DIMM you must replace both FB DIMMs in the pair Each CMP memory module pair supports the following configurations 4 FB DIMMs Group 1 8 FB DIMMs Groups 1 and 2 16 FB DIMMs Groups 1 2 and 3 fully populated configuration 110 SPARC Enterprise T5440 Server Service Manual July 2009 FIGURE Supported FB DIMM Configurations WU TT inn UMA DONON VANADATE MOEA VAT Z Figure Legend 1 Configuration 1 4 FB DIMMs 4 on CMP Module Only 2 Configuration 2 8 FB DIMMs 4 on CMP Module 4 on Memory Module 3 Configuration 3 16 FB DIMMs 4 on CMP Module 12 on Memory Module Note See TABLE FB DIMM Configurations and Device Identifiers on page 112 for a list of device identifiers and the corresponding slots on the CMP memory modules Related Information m Managing Faults on page 9 m FB DIMM Device Identifiers on page 112 a FB DIMM Fault Button Locations on page 113 m Performing Node Reconfiguration on page 155 Servicing Customer Replaceable Units 111 FB DIMM Device Identifiers TABLE FB DIMM Configurations and Device Identifiers on page 112 describes device and device identifiers for FB DIMMs on a CMP and memory module pair Device identifiers are cas
41. removing 81 83 fan tray carriage installing 131 removing 129 fan tray LEDs about 84 fan trays about 81 Fault hard drive LED 31 Fault power supply LED 86 92 fault manager daemon fmd 1M 18 fault records 49 fault recovery I O device 158 fault recovery CMP module 155 faults clearing POST detected faults 48 detected by POST 12 33 35 detected by PSH 12 34 diagnosing with LEDs 30 to 32 environmental 12 13 33 environmental displayed by show faulty command 34 FB DIMM 106 forwarded to ILOM 15 recovery 16 repair 16 types of 33 FB DIMM fault button 113 FB DIMM Fault LEDs 32 FB DIMMS 180 SPARC Enterprise T5440 Server Service Manual July 2009 disabling to run system in degraded state 160 FB DIMMs adding 109 device identifiers 112 diagnosing with fault button 113 diagnosing with show faulty command 106 ejector tabs 105 example POST error output 42 fault handling 21 installing 105 managing faults in 106 re enabling to run system in degraded state 161 removing 105 supported configurations 110 troubleshooting 22 verifying successful replacement 106 flex cable assembly installing 142 removing 141 fmadm command 49 108 fmdump command 45 front bezel installing 117 removing 116 front control panel installing 145 removing 144 front I O board installing 148 removing 147 front panel diagram 3 front panel LEDs 4 FRU event ID 45 FRU ID PROMs 15 FRU information d
42. strap When servicing or removing server components attach an antistatic strap to your wrist and then to a metal area on the chassis Removing the Top Cover V Remove the Top Cover Before you begin complete these tasks Preparing to Service the System 69 m Read the section Safety Information on page 59 m Power off the server using one of the methods described in the section Powering Off the System on page 63 m Extend the Server to the Maintenance Position on page 66 m Perform Electrostatic Discharge Antistatic Prevention Measures on page 69 1 Loosen the two captive No 2 Phillips screws at the rear edge of the top panel 2 Slide the top cover to the rear about 0 5 inch 12 7 mm 3 Remove the top cover Lift up and remove the cover Caution If the top cover is removed before the server is powered off the server will immediately disable the front panel Power button and shut down After such an event you must replace the top cover and use the poweron command to power on the server See Power On the Server on page 153 FIGURE Removing the Top Cover 70 SPARC Enterprise T5440 Server Service Manual July 2009 Servicing Customer Replaceable Units These topics describe how to service customer replaceable units CRUs in the SPARC Enterprise T5440 server Topic Links Read and learn about components which can be serviced while the system is in
43. system FRUs defaults to all FRUs unless one is specified See Display Individual Component Information With the ILOM show Command on page 25 show SYS keyswitch_state showkeyswitch show SYS LOCATE showlocator show SP logs event list showlogs b lines e lines v g lines p logtype r p show SYS showplatform v Displays information about the FRUs in the server Displays the status of the virtual keyswitch Displays the current state of the Locator LED as either on or off Displays the history of all events logged in the service processor event buffers in RAM or the persistent buffers Displays information about the operating state of the host system the system serial number and whether the hardware is providing service TABLE ALOM CMT Parameters and POST Modes on page 56 shows typical combinations of ALOM CMT variables and associated POST modes TABLE ALOM CMT Parameters and POST Modes Normal Diagnostic Mode Diagnostic Service Keyswitch Diagnostic Parameter Default Settings No POST Execution Mode Preset Values diag mode normal Off service normal keyswitch_state normal normal normal diag diag_level max N a max max 56 SPARC Enterprise T5440 Server Service Manual July 2009 TABLE ALOM CMT Parameters and POST Modes Normal Diagnostic Mode Diagnostic Service Keyswitch Diagnostic Parameter Default Settings No POST Execution Mode Preset Values diag_trigger power
44. that all 14 captive screws in the motherboard are retracted Servicing Field Replaceable Units 137 2 Lower the motherboard down into the chassis Guide the flex cable connector through the midwall partition FIGURE Installing the Motherboard 10 Secure the No 2 captive Phillips screws Ensure that all fasteners are secured See FIGURE Motherboard Fastener Locations on page 140 Lower and secure the midwall partition Install the six No 2 Phillips screws that secure the bus bar assembly to the motherboard Install the CMP memory module bracket The bracket is secured with six No 2 Phillips screws Plug in the auxiliary power cable to J9803 Plug in the flex cable connector to J9801 Install the flex cable retainer Place the retainer into position and tighten the captive No 2 Phillips screw Plug in the front I O cable to J9901 138 SPARC Enterprise T5440 Server Service Manual July 2009 Next Steps m Install the Fan Tray Carriage on page 131 m Install a Fan Tray on page 84 Note Install all four fan trays m Install a CMP Memory Module on page 100 Note Install all CMP and memory modules m Install the Service Processor on page 122 m Install a PCIe Card on page 94 m Install the Top Cover on page 150 m Install the Server Into the Rack on page 150 m Connect the Power Cords to the Server on page 153 m Power On the Se
45. 054 Etats Unis Tous droits r serv s Entr e et revue tecnical fournies par FUJITSU LIMITED sur des parties de ce mat riel Sun Microsystems Inc et Fujitsu Limited d tiennent et contr lent toutes deux des droits de propri t intellectuelle relatifs aux produits et technologies d crits dans ce document De m me ces produits technologies et ce document sont prot g s par des lois sur le copyright des brevets d autres lois sur la propri t intellectuelle et des trait s internationaux Les droits de propri t intellectuelle de Sun Microsystems Inc et Fujitsu Limited concernant ces produits ces technologies et ce document comprennent sans que cette liste soit exhaustive un ou plusieurs des brevets d pos s aux Etats Unis et indiqu s a l adresse http www sun com patents de m me qu un ou plusieurs brevets ou applications brevet es suppl mentaires aux Etats Unis et dans d autres pays Ce document le produit et les technologies aff rents sont exclusivement distribu s avec des licences qui en restreignent l utilisation la copie la distribution et la d compilation Aucune partie de ce produit de ces technologies ou de ce document ne peut tre reproduite sous quelque forme que ce soit par quelque moyen que ce soit sans l autorisation crite pr alable de Fujitsu Limited et de Sun Microsystems Inc et de leurs ventuels bailleurs de licence Ce document bien qu il vous ait t fourni ne vous conf re aucun droit e
46. 083 part 541215101 motherboard 0 Location MB CODE EXAMPLE PSH Message Output CPU errors exceeded acceptable levels Type Fault Severity Major Description The number of errors associated with this CPU has exceeded acceptable levels Automated Response The fault manager will attempt to remove the affected CPU from service Impact System performance may be affected Suggested Action for System Administrator 46 SPARC Enterprise T5440 Server Service Manual July 2009 CODE EXAMPLE PSH Message Output Continued Schedule a repair procedure to replace the affected CPU the identity of which can be determined using fmdump v u lt EVENT_ID gt Details The Message ID SUN4V 8000 JA indicates diagnosis has determined that a CPU is faulty The Solaris fault manager arranged an automated attempt to disable this CPU Clearing Faults This section describes how to clear faults Note Some system faults are cleared automatically Task Topic Clear faults detected during POST Clear Faults Detected During POST on page 48 Clear faults detected by PSH Clear Faults Detected by PSH on page 49 Clear faults detected in the Internal I O Clear Faults Detected in the External I O Expansion Unit Expansion Unit on page 50 Related Information Diagnostic Flowchart on page 11 POST Fault Management Overview on page 19 Solaris Predictive Self He
47. 114 shows the location of the FB DIMM fault buttons on the CMP module and the memory module Press this button to illuminate the fault indicator on the module Replace the FB DIMM identified by the indicator Note You must replace a faulty FB DIMM with an identical part same part number See Supported FB DIMM Configurations on page 110 for more information Servicing Customer Replaceable Units 113 FIGURE FB DIMM Fault Button Locations tls Related Information m Managing Faults on page 9 a Supported FB DIMM Configurations on page 110 a FB DIMM Device Identifiers on page 112 114 SPARC Enterprise T5440 Server Service Manual July 2009 Servicing Field Replaceable Units These topics describe how to service field replaceable units FRUs in the SPARC Enterprise T5440 server Note The procedures in this chapter must be performed by a qualified service technician Topic Remove and install field replaceable components Exploded views of FRUs Links Servicing the Front Bezel on page 115 Servicing the DVD ROM Drive on page 118 Servicing the Service Processor on page 120 Servicing the IDPROM on page 123 Servicing the Battery on page 125 Servicing the Power Distribution Board on page 126 Servicing the Fan Tray Carriage on page 129 Servicing the Hard Drive Backplane on page 132 Servicing the Motherboard
48. 4 Place the service processor on an antistatic mat Next Steps If you are replacing a faulty service processor you must install the IDPROM onto the new service processor Do the following m Remove the IDPROM from the old service processor See Remove the IDPROM on page 123 Servicing Field Replaceable Units 121 a Install the IDPROM onto the new service processor See Install the IDPROM on page 124 V Install the Service Processor 1 Ensure that the power cords are disconnected from the system 2 Lower the service processor into position Ensure that the service processor is oriented correctly over the motherboard connector and the two snap on standoffs FIGURE Installing the Service Processor 3 Press down evenly to plug the service processor into the motherboard 4 Secure the service processor with the two captive No 2 Phillips screws 122 SPARC Enterprise T5440 Server Service Manual July 2009 Next Steps m Install the Top Cover on page 150 m Slide the Server Into the Rack on page 151 m Connect the Power Cords to the Server on page 153 m Power On the Server on page 153 Servicing the IDPROM The IDPROM stores system parameters such as host ID and MAC address ILOM configuration settings and OpenBoot PROM configuration settings If you are replacing a faulty service processor you must move the IDPROM from the old service processor to the new one Related Informa
49. 4 SPARC Enterprise T5440 Server Service Manual July 2009 Related Information a Hot Pluggable and Hot Swappable Devices on page 72 m Servicing Hard Drives on page 72 m Servicing Fan Trays on page 81 m Servicing Power Supplies on page 85 m Servicing CMP Memory Modules on page 98 m Servicing FB DIMMs on page 104 m Servicing the Front Bezel on page 115 m Servicing the DVD ROM Drive on page 118 Server Components 175 Field Replaceable Units FIGURE Field Replaceable Units FRUs Figure Legend 1 2 3 CMP memory module bracket 4 Power supply backplane Fan cage 5 Flex cable assembly Hard drive backplane 6 Auxiliary power cable 176 SPARC Enterprise T5440 Server Service Manual July 2009 FIGURE Field Replaceable Units FRUs Motherboard and Auxiliary Boards Figure Legend 1 IDPROM 4 Motherboard 2 Front Control Panel 5 Battery 3 Front I O Board 6 Service Processor Related Information m Servicing the Service Processor on page 120 m Servicing the IDPROM on page 123 m Servicing the Battery on page 125 m Servicing the Power Distribution Board on page 126 Server Components 177 m Servicing the Fan Tray Carriage on page 129 m Servicing the Hard Drive Backplane on page 132 m Servicing the Motherboard on page 135 m Servicing the Flex Cable Assembly on page 140 m Servicing the Front Control
50. 440 Server Service Manual July 2009 FIGURE Installing the Fan Tray Carriage 2 Secure the seven captive No 2 Phillips screws 3 Install the nine No 1Phillips screws Next Steps m Install a Fan Tray on page 84 Note Install all four fan trays m Install the Top Cover on page 150 m Slide the Server Into the Rack on page 151 m Power On the Server on page 153 Servicing the Hard Drive Backplane The hard drive backplane provides the power and data interconnect to the internal hard drives Related Information m Servicing Hard Drives on page 72 Servicing Field Replaceable Units 131 Servicing the Fan Tray Carriage on page 129 V Remove the Hard Drive Backplane Before you begin complete these tasks Read the section Safety Information on page 59 Power off the server using one of the methods described in the section Powering Off the System on page 63 Extend the Server to the Maintenance Position on page 66 Perform Electrostatic Discharge Antistatic Prevention Measures on page 69 Remove the Top Cover on page 69 Remove a Hard Drive on page 77 Note You must remove all four hard drives from the server Note the location of each hard drive you remove You must re install each hard drive in the correct bay Remove a Fan Tray on page 83 Note You must remove all four fan trays Remove the Fan Tray Car
51. 50 m Slide the Server Into the Rack on page 151 m Connect the Power Cords to the Server on page 153 m Power On the Server on page 153 Servicing the Power Distribution Board Main 12V power is connected to the motherboard through a bus bar Standby power and other control signals are routed through the flex cable circuit to the motherboard Related Information m Safety Information on page 59 m Servicing Power Supplies on page 85 V Remove the Power Distribution Board Before you begin complete these tasks m Read the section Safety Information on page 59 m Power off the server using one of the methods described in the section Powering Off the System on page 63 m Disconnect Power Cords From the Server on page 65 m Extend the Server to the Maintenance Position on page 66 a Remove a Power Supply on page 89 Note You must remove all four power supplies from the system m Perform Electrostatic Discharge Antistatic Prevention Measures on page 69 m Remove the Top Cover on page 69 Do the following 126 SPARC Enterprise T5440 Server Service Manual July 2009 1 Remove the flex cable retainer Loosen the captive No 2 Phillips screw and lift the retainer up and out of the chassis 2 Unplug the flex cable from the power distribution board 3 Unplug the auxiliary power cable from the power distribution board 4 Remove the No 2 Ph
52. 51 enable you to view and manually add or remove components asrkeys from the ASR blacklist You run these commands from the ILOM gt prompt TABLE ASR Commands Command Description show components Displays system components and their current state set asrkey component_state Removes a component from the asr db blacklist Enabled where asrkey is the component to enable set asrkey component_state Adds a component to the asr db blacklist where Disabled asrkey is the component to disable Note The asrkeys vary from system to system depending on how many cores and memory are present Use the show components command to see the asrkeys on a given system Note A reset or power cycle is required after disabling or enabling a component If the status of a component is changed there is no effect to the system until the next reset or power cycle Related Information m Diagnostic Flowchart on page 11 m Detecting Faults on page 30 m SPARC Enterprise T5440 Server Administration Guide Managing Faults 51 Vv Disable System Components The component_state property disables a component by adding it to the ASR blacklist 1 At the gt prompt set the component_state property to Disabled gt set SYS MB CPU0 CMP0 BR1 CHO DO component_state Disabled 2 Reset the server so that the ASR command takes effect gt stop SYS Are you sure you want to stop SYS y n y Stopp
53. 5440 Server Service Manual July 2009 Preface This manual provides detailed procedures that describe the removal and replacement of replaceable parts in the SPARC Enterprise T5440 Server This manual also includes information about the use and maintenance of the server This document is written for technicians system administrators authorized service providers ASPs and users who have advanced experience troubleshooting and replacing hardware For Safe Operation This manual contains important information regarding the use and handling of this product Read this manual thoroughly Pay special attention to the section Notes on Safety on page xix Use the product according to the instructions and information available in this manual Keep this manual handy for further reference Keep this manual handy for further reference Fujitsu makes every effort to prevent users and bystanders from being injured or from suffering damage to their property Use the product according to this manual Before You Read This Document To fully use the information in this document you must have thorough knowledge of the topics discussed in the SPARC Enterprise T5440 Server Product Notes xiii Structure and Contents of This Manual This manual is organized as described below m Identifying Server Components on page 1 Provides an overview of the server including major boards and components as well as front and rear panel fe
54. B DIMM notch with the key in the connector This ensures that the FB DIMM is oriented correctly 4 Push the FB DIMM into the connector until the ejector tabs lock the FB DIMM in place If the FB DIMM does not easily seat into the connector verify that the orientation of the FB DIMM is correct If the orientation is reversed damage to the FB DIMM might occur 5 Repeat Step 2 through Step 4 until all replacement FB DIMMs are installed Next Steps a Install a CMP Memory Module on page 100 m Install the Top Cover on page 150 m Slide the Server Into the Rack on page 151 m Power On the Server on page 153 V Verify FB DIMM Replacement 1 Access the ILOM gt prompt Refer to the Integrated Lights Out Manager 3 0 Supplement for SPARC Enterprise T5440 Server for instructions 2 Run the show faulty command to determine how to clear the fault The method you use to clear a fault depends on how the fault is identified by the showfaults command Examples m If the fault is a host detected fault displays a UUID continue to Step 3 For example gt show faulty Target Property Value ee eee ee eee te ce ee ee ee ee S SP faultmgmt 0 fru SYS MB CPU0 CMP0 BRO CH1 D0 SP faultmgmt 0 timestamp Dec 14 22 43 59 SP faultmgmt 0 sunw msg id SUN4V 8000 DxX faults 0 SP faultmgmt 0 uuid 3aa7c854 9667 e176 efe5 e487e520 faults 0 7a8a SP faultmgmt 0 timestamp Dec 14 22 43 59 f
55. MMs Before you begin complete these tasks m Read the section Safety Information on page 59 m Power off the server using one of the methods described in the section Powering Off the System on page 63 m Extend the Server to the Maintenance Position on page 66 m Perform Electrostatic Discharge Antistatic Prevention Measures on page 69 m Remove the Top Cover on page 69 m Remove a CMP Memory Module on page 99 Do the following 1 If you are removing a faulty FB DIMM determine which FB DIMM you want to remove a Press the FB DIMM fault button See FB DIMM Fault Button Locations on page 113 b Note which FB DIMM fault LED is illuminated 2 Push down on the ejector tabs on each side of the FB DIMM until the FB DIMM is released Caution FB DIMMs might be hot Use caution when servicing FB DIMMs 3 Grasp the top corners of the faulty FB DIMM and remove it from the CMP memory module 4 Place the FB DIMM on an antistatic mat 5 Repeat Step 2 through Step 4 to remove any additional FB DIMMs Vv Install FB DIMMs 1 Unpackage the replacement FB DIMMs and place them on an antistatic mat Tip See Supported FB DIMM Configurations on page 110 for information about configuring the FB DIMMs 2 Ensure that the ejector tabs are in the open position Servicing Customer Replaceable Units 105 3 Line up the replacement FB DIMM with the connector Align the F
56. MP0 BR1 CHO D0O component_state Enabled The fault is cleared and should not show up when you run the show faulty command Additionally the Service Required LED is no longer on 3 Reset the server You must reboot the server for the component_state property to take effect 4 At the ILOM prompt use the show faulty command to verify that no faults are reported gt show faulty Target Property Value Se aa ee ee ee eee an Seen taste oaeeees CODE EXAMPLE Fault Detected by POST gt show faulty Target Property Value SP faultmgmt 0 fru SYS MB CPU0 CMP0 BR1 CH0 DO 48 SPARC Enterprise T5440 Server Service Manual July 2009 CODE EXAMPLE Fault Detected by POST Continued SP faultmgmt 0 timestamp Dec 21 16 40 56 SP faultmgmt 0 timestamp Dec 21 16 40 56 faults 0 SP faultmgmt 0 sp_detected_fault SYS MB CPU0 CMP0 BR1 CH0 D0 faults 0 Forced fail POST Vv Clear Faults Detected by PSH When the Solaris PSH facility detects faults the faults are logged and displayed on the console In most cases after the fault is repaired the corrected state is detected by the system and the fault condition is repaired automatically However this repair should be verified In cases where the fault condition is not automatically cleared the fault must be cleared manually 1 After replacing a faulty FRU power on the server 2 At the ILOM prompt use the show faulty command
57. Memory Module If your system experiences a complete CMP memory module failure do one of the following 1 Replace the failed CMP memory module 2 If a replacement CMP module is not available remove the failed CMP module and replace it with a CMP from a different slot that does not have any directly connected I O devices in use see TABLE Devices controlled by CMPs in 2P systems on page 164 andTABLE Devices controlled by CMPs in 4P systems on page 165 If this leaves a memory module without its associated CMP module remove the memory module Note At a minimum a functioning CMP module must be installed in CMP Slot 0 If you are performing a node reconfiguration following a failure in CMP Slot 0 you must move one of the remaining CMP modules to CMP Slot 0 3 If neither option 1 nor 2 is possible you must do the following a Temporarily Disable All Memory Modules on page 160 m Reconfigure the I O and PCIe Fabric on page 158 m Re Enable All Memory Modules on page 161 m Reset the LDoms Guest Configuration on page 162 Related Information m Managing Faults on page 9 m Servicing CMP Memory Modules on page 98 m Servicing FB DIMMs on page 104 m I O Connections to CMP Memory Modules on page 156 m Reconfiguring I O Device Nodes on page 158 m System Bus Topology on page 162 m I O Fabric in 2P Configuration on page 164 m I O Fabric in 4P Configuration
58. OM CMT Command Reference on page 53 m SPARC Enterprise T5440 Server Installation and Setup Guide m SPARC Enterprise T5440 Server Administration Guide m Integrated Lights Out Manager 3 0 Supplement for SPARC Enterprise T5440 Server View ILOM Event Log Type the following command gt show SP logs event list Note The ILOM event log can also be viewed through the ILOM BUI or the ALOM CMT CLI If a major or critical event is found that was not expected and not included under ILOM show faulty than it may indicate a system fault The following is an example of unexpected major events in the log gt show sp logs event list 1626 Fri Feb 15 18 57 29 2008 Chassis Log major Feb 15 18 57 29 ERROR CMPO Only 4 cores up to 32 cpus are configured because some L2_ BANKS are unusable 1625 Fri Feb 15 18 57 28 2008 Chassis Log major Feb 15 18 57 28 ERROR System DRAM Available 004096 MB 1624 Fri Feb 15 18 57 28 2008 Chassis Log major Feb 15 18 57 28 ERROR CMP1 memc_1_1 unused because associated L2 banks on CMPO cannot be used Managing Faults 37 1623 Fri Feb 15 18 57 27 2008 Chassis Log major Feb 15 18 57 27 ERROR Degraded configuration system operating at reduced capacity 1622 Fri Feb 15 18 57 27 2008 Chassis Log major Feb 15 18 57 27 ERROR CMP0 MB CPU0 CMP0 BR1 neither channel populated with DIMMO Branch 1 not configured Detecting Faults Using SunVTS Sof
59. Powering Off the System on page 63 m Disconnect Power Cords From the Server on page 65 m Perform Electrostatic Discharge Antistatic Prevention Measures on page 69 Note If you are servicing Power Supply 0 you must disconnect the cable management arm support strut 1 Grasp the power supply handle and press the release latch FIGURE Removing a Power Supply 2 Pull the power supply out of the chassis Servicing Customer Replaceable Units 89 V Install a Power Supply If you are installing the power supplies following another service tasks complete these steps 1 Align the replacement power supply with the empty power supply bay FIGURE Installing a Power Supply 2 Slide the power supply into the bay until it is fully seated Next Steps m Connect the Power Cords to the Server on page 153 m Power On the Server on page 153 90 SPARC Enterprise T5440 Server Service Manual July 2009 Power Supply Device Identifiers TABLE Power Supply FRU Names on page 91 describes the FRU device names for power supplies in the servers TABLE Power Supply FRU Names Device Device Identifier PSO SYS PSO PS1 SYS PS1 PS2 SYS PS2 PS3 SYS PS3 Note Power supply names in ILOM messages are displayed with the full FRU name such as SYS PSO Related Information m Managing Faults on page 9 m Hot Pluggable and Hot Swappable Devices on page 72 m Power
60. Reconnect the cables to the back of the server If the CMA is in the way slide the server partially out of the cabinet to access the necessary rear panel connections 152 SPARC Enterprise T5440 Server Service Manual July 2009 V Connect the Power Cords to the Server Reconnect both power cords to the power supplies Note As soon as the power cords are connected standby power is applied Depending on the configuration of the firmware the system might boot See the SPARC Enterprise T5440 Server Administration Guide for configuration and power on information V Power On the Server To power on the server do one of the following To initiate the power on sequence from the service processor prompt issue the poweron command You will see an gt Alert message on the system console This message indicates that the system is reset You will also see a message indicating that the VCORE has been margined up to the value specified in the default scr file that was previously configured Example start SYS To initiate the power on sequence manually use a pen or pencil to press the Power button on the front panel See Front Panel Diagram on page 3 for Power button location Note If you are powering on the server following an emergency shutdown triggered by the top cover interlock switch you must use the poweron command Returning the Server to Operation 153 154 SPARC Enterprise T5440
61. SPARC Enterprise T5440 Server Administration Guide Detecting Faults Using POST Run POST in maximum mode to detect system faults See Run POST in Maximum Mode on page 28 POST error messages use the following syntax c gt ERROR TEST failing test c S gt H W under test FRU c S gt Repair Instructions Replace items in order listed by H W under test above c gt MSG test error message C gt END_ERROR In this syntax c the core number s the strand number Warning and informational messages use the following syntax 42 SPARC Enterprise T5440 Server Service Manual July 2009 INFO or WARNING message In CODE EXAMPLE POST Error Message on page 43 POST reports a memory error at FB DIMM location SYS MB CPU0 CMP0 BR1 CH0 DO The error was detected by POST running on core 7 strand 2 CODE EXAMPLE POST Err or Message 7 2 gt 7 2 gt ERROR TEST Data Bitwalk 7 2 gt H W under test SYS MB CPU0 CMP0 BR1 CH0 DO 7 2 gt Repair Instructions Replace items in order listed by H W under test above 7 2 gt MSG Pin 149 failed on SYS MB CPU0 CMP0 BR1 CH0O DO J792 7 2 gt END_ERROR 7 2 gt Decode of Dram 60000000 0000108c Error Log Reg Channel 2 bits 7 2 gt 1 MEC 62 R W1C Multiple corrected errors one or more CE not logged 7 2 gt 1 DAC 61 R W1C Set to 1 if the error was a DRAM access CE 7 2 gt 108c SYND 15 0 RW ECC syndrome 2 gt
62. SYS HDD1 c0 dsk d1t1d0 HDD2 SYS HDD2 c0 dsk d1t2d0 HDD3 SYS HDD3 c0 dsk d1t3d0 Note Hard drive names in ILOM messages are displayed with the full FRU name such as SYS HDD0 Servicing Customer Replaceable Units 79 Related Information a Hard Drive LEDs on page 80 Hard Drive LEDs FIGURE Hard Drive LEDs TABLE Hard Drive Status LEDs No LED Color Notes 1 Ready Blue This LED is lit to indicate that a hard drive to Remove 4 is can be removed safely during a hot plug operation 2 Service Amber This LED is lit when the system is running Required AN and the hard drive is faulty 3 OK Activity Green This LED lights when data is being read from or written to the hard drive The front and rear panel Service Required LEDs are also lit if the system detects a hard drive fault Related Information a Hard Drive Device Identifiers on page 79 80 SPARC Enterprise T5440 Server Service Manual July 2009 Servicing Fan Trays Four fan trays are located toward the front of the server arranged in two N 1 redundant pairs Each fan tray contains a fan mounted in an integrated hot swappable CRU If a fan tray fails replace it as soon as possible to maintain server availability Caution Hazardous moving parts Unless the power to the server is completely shut down the only service permitted in the fan compartment is the replacement of the fan trays by trained personnel Related I
63. aPCleCard 94 PCIe Device Identifiers 96 PCle Slot Configuration Guidelines 97 Servicing CMP Memory Modules 98 v Remove a CMP Memory Module 99 v Installa CMP Memory Module 100 v AddaCMP Memory Module 101 CMP and Memory Module Device Identifiers 103 Supported CMP Memory Module Configurations 104 Servicing FB DIMMs 104 v Remove FB DIMMs 105 v Install FB DIMMs 105 v Verify FB DIMM Replacement 106 v Add FB DIMMs 109 Supported FB DIMM Configurations 110 FB DIMM Device Identifiers 112 FB DIMM Fault Button Locations 113 Servicing Field Replaceable Units 115 Servicing the Front Bezel 115 v Remove the Front Bezel 116 v Install the Front Bezel 117 Servicing the DVD ROM Drive 118 v Remove the DVD ROM Drive 118 v Install the DVD ROM Drive 119 Servicing the Service Processor 120 v Remove the Service Processor 120 Contents ix x v Install the Service Processor 122 Servicing the IDPROM 123 v Remove the IDPROM 123 v Installthe IDPROM 124 Servicing the Battery 125 v Remove the Battery 125 v Install the Battery 125 Servicing the Power Distribution Board 126 v Remove the Power Distribution Board 126 v Install the Power Distribution Board 128 Servicing the Fan Tray Carriage 129 v Remove the Fan Tray Carriage 129 v Install the Fan Tray Carriage 131 Servicing the Hard Drive Backplane 132 v Remove the Hard Drive Backplane 132 v Install the Hard Drive Backplane 133 Servicing the Motherboard 135 v Remove the Motherboar
64. acket The bracket is secured with six captive No 2 Phillips screws See FIGURE CMP Memory Module Bracket Captive Screw Locations on page 136 FIGURE CMP Memory Module Bracket Captive Screw Locations ie A J i a IO ENM m 2 Remove the flex cable retainer Loosen the captive No 2 Phillips screw and lift the retainer up and out of the chassis 3 Unplug the flex cable from J9801 on the motherboard 4 Unplug the auxiliary power cable from J9803 on the motherboard 136 SPARC Enterprise T5440 Server Service Manual July 2009 5 Unplug the front I O connector from J9901 on the motherboard 6 Remove the six No 2 Phillips screws that secure the bus bar assembly to the motherboard 7 Slide the chassis midwall panel up Note Use the clips to secure the midwall panel in the open position 8 Loosen the No 2 Phillips screws that secure the motherboard to the chassis floor See FIGURE Motherboard Fastener Locations on page 140 for the fastener locations 9 Lift the motherboard up and out of the chassis Guide the flex cable connector out from under the midwall partition FIGURE Removing the Motherboard 10 Place the motherboard on an antistatic mat Next Steps If you are replacing a faulty motherboard you must program the chassis serial number and product part number into the new motherboard See your service representative VY Install the Motherboard 1 Ensure
65. ady populated with a device install a new device in the next available slot in the order indicated TABLE PCIe Slot Configuration Guidelines Number of CMP Memory PCle XAUI Card Type Modules Installation Order Notes 10 GBit Ethernet XAUI 1 2 3 or 4 Slot 4 5 Install XAUI cards first card External I O Expansion 2 Slot 0 4 1 5 Maximum of 4 cards install in order Unit PCIe Link card shown 4 Slot 0 4 2 6 1 5 3 7 Maximum of 8 cards install in order shown All other devices 2 Slot 0 4 1 5 2 6 3 7 Maximum of 8 cards install in order shown 4 Slot 0 4 2 6 1 5 3 7 Maximum of 8 cards install in order shown These are guidelines to spread out the I O load across multiple CMP memory module pairs These are not configuration restrictions External I O Expansion Unit PCIe Link cards must be placed in a PCIe slot with a CMP memory module pair present as follows m PCle Slots 0 and 1 require CMP Memory pair 0 m PCle Slots 4 and 5 require CMP Memory pair 1 m PCle Slots 2 and 3 require CMP Memory pair 2 m PCle Slots 6 and 7 require CMP Memory pair 3 Related Information m PCle Device Identifiers on page 96 m System Bus Topology on page 162 m I O Fabric in 2P Configuration on page 164 m I O Fabric in 4P Configuration on page 165 Servicing Customer Replaceable Units 97 Servicing CMP Memory Modules Up to four CMP memory modules can be installed in the system Each CMP mod
66. age 44 m SPARC Enterprise T5440 Server Administration Guide SunVTS Overview Sometimes a server exhibits a problem that cannot be isolated definitively to a particular hardware or software component In such cases it might be useful to run a diagnostic tool that stresses the system by continuously running a comprehensive battery of tests SunVTS software is provided for this purpose Related Information m Diagnostic Flowchart on page 11 18 SPARC Enterprise T5440 Server Service Manual July 2009 m SunVTS Software Packages on page 41 m Useful SunVTS Tests on page 42 m SPARC Enterprise T5440 Server Administration Guide POST Fault Management Overview Power on self test POST is a group of PROM based tests that run when the server is powered on or reset POST checks the basic integrity of the critical hardware components in the server CMP memory and I O subsystem POST tests critical hardware components to verify functionality before the system boots and accesses software If POST detects a faulty component the component is disabled automatically preventing faulty hardware from potentially harming any software If the system is capable of running without the disabled component the system will boot when POST is complete For example if one of the processor cores is deemed faulty by POST the core will be disabled The system will boot and run using the remaining cores You can use POST as an initial diagnosti
67. age 69 Remove the Top Cover on page 69 Do the following 1 Identify the correct slot for installation Servicing Customer Replaceable Units 101 2 Remove the air baffle Squeeze the air baffle latches toward each other and lift the air baffle straight up and out of the chassis 3 If you are installing the module into a previously empty slot remove the plastic connector cover on the motherboard 4 Slide the module down into its slot FIGURE Installing a CMP Module gt ja OTT WN LU LULL EA l fi Se aS ae ee 5 Rotate the ejector levers down to secure the module into place Next Steps m Install the Top Cover on page 150 m Slide the Server Into the Rack on page 151 m Power On the Server on page 153 102 SPARC Enterprise T5440 Server Service Manual July 2009 CMP and Memory Module Device Identifiers TABLE CMP Memory Module Device Identifier on page 103 describes device device identifiers and supported configurations for CMP and memory modules Device identifiers are case sensitive TABLE CMP Memory Module Device Identifier Device Device Identifier CMPO SYS MB CPU0 CMPO0 MEMO SYS MB MEM0 CMPO0 CMP1 SYS MB CPU1 CMP1 MEM1 SYS MB MEM1 CMP1 CMP2 SYS MB CPU2 CMP2 MEM2 SYS MB MEM2 CMP2 CMP3 SYS MB CPU3 CMP3 MEMS3 SYS MB MEM3 CMP3 Note CMP and memory module names in ILOM messages are displayed with the full FRU n
68. aling Overview on page 17 SPARC Enterprise T5440 Server Administration Guide Integrated Lights Out Manager 3 0 Supplement for SPARC Enterprise T5440 Server External I O Expansion Unit Installation and Service Manual for SPARC Enterprise T5120 T5140 T5220 T5240 T5440 Servers Managing Faults 47 Vv Clear Faults Detected During POST In most cases when POST detects a faulty component POST logs the fault and automatically takes the failed component out of operation by placing the component in the ASR blacklist See Disabling Faulty Components on page 50 In most cases the replacement of the faulty FRU is detected when the service processor is reset or power cycled In this case the fault is automatically cleared from the system This procedure describes how to identify a POST detected fault and if necessary manually clear the fault 1 After replacing a faulty FRU at the ILOM prompt use the show faulty command to identify POST detected faults Faults detected by POST are distinguished from other kinds of faults by the text Forced fail No UUID number is reported Refer to CODE EXAMPLE Fault Detected by POST on page 48 If no fault is reported you do not need to do anything else Do not perform the subsequent steps 2 Use the component_state property of the component to clear the fault and remove the component from the ASR blacklist Use the FRU name that was reported in the fault in Step 1 gt set SYS MB CPU0 C
69. ame such as SYS MB CPUO Related Information m Managing Faults on page 9 m Supported FB DIMM Configurations on page 110 m Performing Node Reconfiguration on page 155 Servicing Customer Replaceable Units 103 Supported CMP Memory Module Configurations TABLE Supported CMP Memory Module Configurations on page 104 shows the supported CMP memory module configurations as viewed from the front of the server TABLE Supported CMP Memory Module Configurations CMP3 CMP1 CMP2 CMPO Configuration MEM3 MEM1 MEM2 MEMO One CMP memory pair Two CMP memory pairs X Three CMP memory pairs X X X x lt Four CMP memory pairs X full configurations Related Information a CMP and Memory Module Device Identifiers on page 103 m Performing Node Reconfiguration on page 155 Servicing FB DIMMs Up to 16 FB DIMMs can be installed in each CMP memory module pair Related Information m Managing Faults on page 9 m Remove FB DIMMs on page 105 m Install FB DIMMs on page 105 m Verify FB DIMM Replacement on page 106 m Add FB DIMMs on page 109 a Supported FB DIMM Configurations on page 110 a FB DIMM Device Identifiers on page 112 a FB DIMM Fault Button Locations on page 113 m Servicing CMP Memory Modules on page 98 m Performing Node Reconfiguration on page 155 104 SPARC Enterprise T5440 Server Service Manual July 2009 V Remove FB DI
70. and replace a power supply without shutting the server down provided that at least two other power supplies are online and working Note If a power supply fails and you do not have a replacement available leave the failed power supply installed to ensure proper airflow in the server Related Information m Identifying Server Components on page 1 m Managing Faults on page 9 a Hot Pluggable and Hot Swappable Devices on page 72 m Power Supply Device Identifiers on page 91 Servicing Customer Replaceable Units 85 m Power Supply LED on page 91 m Server Components on page 173 m SPARC Enterprise T5440 Server Site Planning Guide V Remove a Power Supply Hot Swap Caution Hazardous voltages are present To reduce the risk of electric shock and danger to personal health follow the instructions Note If you are servicing Power Supply 0 you must disconnect the cable management arm support strut 1 Identify which power supply requires replacement An amber LED on a power supply indicates that a failure was detected In addition the show faulty command indicates which power supply is faulty See Detecting Faults on page 30 2 Gain access to the rear of the server where the faulty power supply is located If necessary slide the system partially out of the rack to obtain better access to the rear panel 3 Disconnect the power cord from the faulty power supply 4 G
71. anings of the following symbols that might appear in this document Caution There is a risk of personal injury or equipment damage To avoid personal injury and equipment damage follow the instructions Caution Hot surface Avoid contact Surfaces are hot and might cause personal injury if touched Caution Hazardous voltages are present To reduce the risk of electric shock and danger to personal health follow the instructions Related Information m Safety Information on page 59 60 SPARC Enterprise T5440 Server Service Manual July 2009 Electrostatic Discharge Safety Measures Electrostatic discharge ESD sensitive devices such as the motherboard PCI cards hard drives and memory modules require special handling Caution Circuit boards and hard drives contain electronic components that are extremely sensitive to static electricity Ordinary amounts of static electricity from clothing or the work environment can destroy the components located on these boards Do not touch the components along their connector edges Caution You must disconnect both power supplies before servicing any of the components documented in this chapter Related Information m Safety Information on page 59 m Antistatic Wrist Strap on page 61 m Antistatic Mat on page 61 Antistatic Wrist Strap Wear an antistatic wrist strap and use an antistatic mat when handling components such as
72. ant to which the product or technology is provided EXCEPT AS EXPRESSLY SET FORTH IN SUCH AGREEMENT FUJITSU LIMITED SUN MICROSYSTEMS INC AND THEIR AFFILIATES MAKE NO REPRESENTATIONS OR WARRANTIES OF ANY KIND EXPRESS OR IMPLIED REGARDING SUCH PRODUCT OR TECHNOLOGY OR THIS DOCUMENT WHICH ARE ALL PROVIDED AS IS AND ALL EXPRESS OR IMPLIED CONDITIONS REPRESENTATIONS AND WARRANTIES INCLUDING WITHOUT LIMITATION ANY IMPLIED WARRANTY OF MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE OR NON INFRINGEMENT ARE DISCLAIMED EXCEPT TO THE EXTENT THAT SUCH DISCLAIMERS ARE HELD TO BE LEGALLY INVALID Unless otherwise expressly set forth in such agreement to the extent allowed by applicable law in no event shall Fujitsu Limited Sun Microsystems Inc or any of their affiliates have any liability to any third party under any legal theory for any loss of revenues or profits loss of use or data or business interruptions or for any indirect special incidental or consequential damages even if advised of the possibility of such damages DOCUMENTATION IS PROVIDED AS IS AND ALL EXPRESS OR IMPLIED CONDITIONS REPRESENTATIONS AND WARRANTIES INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE OR NON INFRINGEMENT ARE DISCLAIMED EXCEPT TO THE EXTENT THAT SUCH DISCLAIMERS ARE HELD TO BE LEGALLY INVALID eo Sea 4 Adobe PostScript Copyright 2009 Sun Microsystems Inc 4150 Network Circle Santa Clara California 95
73. are Packages on page 41 lists SunVTS packages TABLE SunVTS Software Packages Package Description SUNWvts Test development library APIs and SunVTS kernel You must install this package to run the SunVTS software SUNWvtsmn Man pages for the SunVTS utilities including the command line utility SUNWvtsr SunVTS framework root SUNWvtss SunVTS browser user interface BUI components required on the server system SUNWvtsts SunVTS test binaries Related Information m Diagnostic Flowchart on page 11 m Useful SunVTS Tests on page 42 m SPARC Enterprise T5440 Server Installation and Setup Guide m SPARC Enterprise T5440 Server Administration Guide Managing Faults 41 Useful SunVTS Tests TABLE Useful SunVTS Tests on page 42 describes the SunVTS tests which are useful for diagnosing issues with the SPARC Enterprise T5440 server TABLE Useful SunVTS Tests SunVTS Tests FRUs Exercised by Tests Memory Test FB DIMMs Processor Test CMP motherboard Disk Test Disks cables disk backplane DVD drive Network Test Network interface network cable CMP motherboard Interconnect Test Board ASICs and interconnects IO Ports Test I O serial port interface USB subsystem Environmental Test Motherboard and service processor Related Information a Diagnostic Flowchart on page 11 m SunVTS Software Packages on page 41 m SPARC Enterprise T5440 Server Installation and Setup Guide m
74. aris Predictive Self Healing software page 44 If the fault is a PSH detected fault refer to the PSH Knowledge Article web site for additional Clear Faults Detected by information The Knowledge Article for the fault is PSH on page 49 located at the following link http www sun com msg message ID where message ID is the value of the sunw msg id property displayed by the show faulty command After the FRU is replaced perform the procedure to clear PSH detected faults 9 Determine if the POST performs basic tests of the server components POST Fault Management fault was detected and reports faulty FRUs When POST detects a Overview on page 19 by POST faulty FRU it logs the fault and if possible takes the FRU offline POST detected FRUs display the Clear Paults Detected following text in the fault message During POST on page 48 Forced fail reason In a POST fault message reason is the name of the power on routine that detected the failure 10 Contact technical The majority of hardware faults are detected by the Obtain the Chassis Serial support server s diagnostics In rare cases a problem might Number on page 62 require additional troubleshooting If you are unable to determine the cause of the problem contact your service representative for support Related Information m Server Diagnostics Overview on page 9 m SPARC Enterprise T5440 Server Administration Guide Options for Accessing the Service Processo
75. atically by POST 51 disabling using disablecomponent command 52 displaying state of 51 displaying using showcomponent command 24 179 configuration device addresses 156 connecting to ALOM CMT 22 console command 29 53 108 consolehistory command 54 D DC OK power supply LED 91 device identifiers CMP memory modules 103 fan tray 84 FB DIMMs 112 hard drive 79 PCIe card 96 power supply 91 diag_level parameter 27 56 diag_mode parameter 26 56 diag_trigger parameter 27 57 diag_verbosity parameter 27 57 diagnostics about 9 flowchart 11 low level 19 running remotely 15 using SunVTS 18 disablecomponent command 52 displaying FRU status 25 dmesg command 36 DVD ROM drive installing 119 removing 118 E ejector tabs FB DIMM 105 electrostatic discharge ESD preventing 69 preventing using an antistatic mat 61 preventing using an antistatic wrist strap 61 safety measures 61 emergency shutdown 65 using Power button 5 enablecomponent command 48 environmental faults 12 13 16 33 event log checking the PSH 45 EVENT_ID FRU 45 exercising the system with SunVTS 38 External I O Expansion Unit fault detected by show faulty command 35 faults detection in 15 F Fan Fault system LED interpreting to diagnose faults 31 fan module determining fault state 31 Fault LED 31 fan module LEDs using to identify faults 31 fan tray 83 device identifiers 84 installing 82 84
76. ating state e Fast blink System received a signal as a result of one of the methods previously mentioned indicating that it is active Service If on indicates that service is required POST and ILOM are two diagnostics Required LED tools that can detect a fault or failure resulting in this indication amber The ILOM show faulty command provides details about any faults that cause this indicator to light Under some fault conditions individual component fault LEDs are lit in addition to the system Service Required LED Power OK Provides the following indications LED e Off Indicates that the system is not running in its normal state System green power might be off The service processor might be running e Steady on Indicates that the system is powered on and is running in its normal operating state No service actions are required Fast blink Indicates the system is running at a minimum level in standby and is ready to be quickly returned to full function The service processor is running e Slow blink Indicates that a normal transitory activity is taking place Slow blinking could indicate that the system diagnostics are running or that the system is booting 4 SPARC Enterprise T5440 Server Service Manual July 2009 TABLE Front Panel LEDs and Controls Continued LED or Button Icon Description Power button Fan Fault LED amber Power Supply Fault LED amber Overtemp LED
77. atures m Managing Faults on page 9 Describes the diagnostics that are available for monitoring and troubleshooting the server m Preparing to Service the System on page 59 Describes the steps necessary to prepare the server for service m Servicing Customer Replaceable Units on page 71 Describes how to service customer replaceable units CRUs m Servicing Field Replaceable Units on page 115 Describes how to service field replaceable units FRUs m Returning the Server to Operation on page 149 Describes how to bring the server back to operation after performing service procedures m Performing Node Reconfiguration on page 155 Describes how to perform node reconfiguration m Connector Pinouts on page 167 Contains pinout tables for all external connectors m Server Components on page 173 Contains illustrations showing server components xiv SPARC Enterprise T5440 Server Service Manual July 2009 Related Documentation The latest versions of all the SPARC Enterprise Series manuals are available at the following Web sites Global Site http www fujitsu com sparcenterprise manual Japanese Site http primeserver fujitsu com sparcenterprise manual Title Description Manual Code SPARC Enterprise T5440 Server Getting Started Guide SPARC Enterprise T5440 Server Product Notes Important Safety Information for Hardware Systems SPARC Enterprise T5440
78. aults 0 106 SPARC Enterprise T5440 Server Service Manual July 2009 In most cases if the fault was detected by POST and resulted in the FB DIMM being disabled such as the following example the replacement of the faulty FB DIMM is detected when the service processor is power cycled In this case the fault is automatically cleared from the system gt show faulty Target Property Value fed Be EN SASL ee seen lh Ses Bonet a tae dN Ms aS ens ohare nena geet tas Rape Aaa ea Ae Ne aE eae SP faultmgmt 0 fru SYS MB CPU0 CMP0 BR1 CHO DO SP faultmgmt 0 timestamp Dec 21 16 40 56 SP faultmgmt 0 timestamp Dec 21 16 40 56 faults 0 SP faultmgmt 0 sp_detected_fault SYS MB CPU0 CMP0 BR1 CH0 DO faults 0 Forced fail POST If the fault is still displayed by the show faulty command then run the set command to enable the FB DIMM and clear the fault Example gt set SYS MB CPU0 CMP0 BR0 CH0 D0 component_state Enabled 3 Perform the following steps to verify the repair a Set the virtual keyswitch to diag so that POST will run in Service mode gt set SYS keyswitch_state Diag Set keyswitch_state to Diag b Power cycle the system gt stop SYS Are you sure you want to stop SYS y n y Stopping SYS gt start SYS Are you sure you want to start SYS y n y Starting SYS Note The server takes about one minute to power off Use the show HOST
79. ble management arm CMA to the rack rail FIGURE Removing the Server From the Rack on page 68 Slide the CMA out of the end of the inner glide The CMA is still attached to the cabinet but the server is now disconnected from the CMA FIGURE Removing the Server From the Rack Figure Legend 1 Disconnect system cables and CMA 2 Press inner rail release buttons to remove the server from the rack Caution Use two people to dismount and carry the chassis 4 From the front of the server press inner rail release buttons and pull the server forward until it is free of the rack rails 5 Set the server on a sturdy work surface 68 SPARC Enterprise T5440 Server Service Manual July 2009 Performing Electrostatic Discharge Antistatic Prevention Measures Related Information m Electrostatic Discharge Safety Measures on page 61 m Perform Electrostatic Discharge Antistatic Prevention Measures on page 69 V Perform Electrostatic Discharge Antistatic Prevention Measures 1 Prepare an antistatic surface to set parts on during the removal installation or replacement process Place ESD sensitive components such as the printed circuit boards on an antistatic mat The following items can be used as an antistatic mat m Antistatic bag used to wrap a replacement part m ESD mat m A disposable ESD mat shipped with some replacement parts or optional system components 2 Attach an antistatic wrist
80. c tool for the system hardware In this case configure POST to run in maximum mode diag_mode service setkeyswitch diag diag_level max for thorough test coverage and verbose output Managing Faults 19 POST Fault Management Flowchart FIGURE Flowchart of Variables for POST Configuration Service Mode Forces a Sun prescribed level of diagnostic execution Overrides user defined settings as if parameters were diag_level max diag_verbosity max diag_trigger all resets diag_mode User defined settings are not modified Normal Mode Diagnostic execution is enabled User defined settings control test coverage and verbosity via diag_level diag_verbosity diag_trigger user_reset power _on_reset error_reset System Boot OpenBoot PROM Solaris boot Related Information m Diagnostic Flowchart on page 11 20 SPARC Enterprise T5440 Server Service Manual July 2009 m Detecting Faults Using POST on page 42 m SPARC Enterprise T5440 Server Installation and Setup Guide m SPARC Enterprise T5440 Server Administration Guide Memory Fault Handling Overview A variety of features play a role in how the memory subsystem is configured and how memory faults are handled Understanding the underlying features helps you identify and repair memory problems This section describes how the server deals with memory faults Note For memory configuration information see Sup
81. cO FUJITSU SPARC Enterprise T5440 Server Service Manual C120 E512 02EN c FUJITSU SPARC Enterprise T5440 Server Service Manual Manual Code C120 E512 02EN Part No 875 4392 11 July 2009 Revision A Copyright 2009 Sun Microsystems Inc 4150 Network Circle Santa Clara California 95054 U S A All rights reserved FUJITSU LIMITED provided technical input and review on portions of this material Sun Microsystems Inc and Fujitsu Limited each own or control intellectual property rights relating to products and technology described in this document and such products technology and this document are protected by copyright laws patents and other intellectual property laws and international treaties The intellectual property rights of Sun Microsystems Inc and Fujitsu Limited in such products technology and this document include without limitation one or more of the United States patents listed at http www sun com patents and one or more additional patents or patent applications in the United States or other countries This document and the product and technology to which it pertains are distributed under licenses restricting their use copying distribution and decompilation No part of such product or technology or of this document may be reproduced in any form by any means without prior written authorization of Fujitsu Limited and Sun Microsystems Inc and their applicable licensors if any The furnishi
82. cables stipul es dans le FAR et ses suppl ments Avis de non responsabilit les seules garanties octroy es par Fujitsu Limited Sun Microsystems Inc ou toute soci t affili e de l une ou l autre entit en rapport avec ce document ou tout produit ou toute technologie d crit e dans les pr sentes correspondent aux garanties express ment stipul es dans le contrat de licence r gissant le produit ou la technologie fourni e SAUF MENTION CONTRAIRE EXPRESS MENT STIPULEE DANS CE CONTRAT FUJITSU LIMITED SUN MICROSYSTEMS INC ET LES SOCIETES AFFILIEES REJETTENT TOUTE REPRESENTATION OU TOUTE GARANTIE QUELLE QU EN SOIT LA NATURE EXPRESSE OU IMPLICITE CONCERNANT CE PRODUIT CETTE TECHNOLOGIE OU CE DOCUMENT LESQUELS SONT FOURNIS EN L ETAT EN OUTRE TOUTES LES CONDITIONS REPRESENTATIONS ET GARANTIES EXPRESSES OU TACITES Y COMPRIS NOTAMMENT TOUTE GARANTIE IMPLICITE RELATIVE A LA QUALITE MARCHANDE A L APTITUDE A UNE UTILISATION PARTICULIERE OU A L ABSENCE DE CONTREFA ON SONT EXCLUES DANS LA MESURE AUTORISEE PAR LA LOI APPLICABLE Sauf mention contraire express ment stipul e dans ce contrat dans la mesure autoris e par la loi applicable en aucun cas Fujitsu Limited Sun Microsystems Inc ou l une de leurs filiales ne sauraient tre tenues responsables envers une quelconque partie tierce sous quelque th orie juridique que ce soit de tout manque gagner ou de perte de profit de probl mes d utilisation ou de perte de donn es
83. cated on the system motherboard and can be accessed from the back panel The Ethernet interfaces operate at 10 Mbit sec 100 Mbit sec and 1000 Mbit sec 170 SPARC Enterprise T5440 Server Service Manual July 2009 FIGURE 1 8 Le Gigabit Ethernet Connector Diagram TABLE Gigabit Ethernet Connector Signals Pin Signal Description Pin Signal Description 1 Transmit Receive Data 0 5 Transmit Receive Data 2 2 Transmit Receive Data 0 6 Transmit Receive Data 1 3 Transmit Receive Data 1 7 Transmit Receive Data 3 4 Transmit Receive Data 2 8 Transmit Receive Data 3 Connector Pinouts 171 172 SPARC Enterprise T5440 Server Service Manual July 2009 Server Components This section provides illustrations depicting system components Description Links A diagram and list of customer Customer Replaceable Units on page 174 replaceable units CRUs A diagram and list of components Field Replaceable Units on page 176 that only field service personnel can replace Related Information m Identifying Server Components on page 1 m Servicing Customer Replaceable Units on page 71 m Servicing Field Replaceable Units on page 115 173 Customer Replaceable Units FIGURE Customer Replaceable Units CRUs Figure Legend CMP modules Front bezel Memory modules Hard drives Power supplies on oa 1 2 3 Fan trays 4 Removable media drive 17
84. cation of each hard drive Servicing Customer Replaceable Units 77 Note You must install each hard drive in the same bay from which it was removed 2 Press the hard drive latch release button FIGURE Removing a Hard Drive 3 Slide the hard drive out of its bay Vv Install a Hard Drive If you are installing a hard drive after servicing another component in the system do the following 1 Align the replacement drive to the drive slot Hard drives are physically addressed according to the slot in which they are installed If you removed an existing hard drive from a slot in the server you must install the replacement drive in the same slot as the drive that was removed 2 Slide the drive into the drive slot until it is fully seated 78 SPARC Enterprise T5440 Server Service Manual July 2009 FIGURE Installing a Hard Drive 3 Close the latch to lock the drive in place 4 If you performed any additional service procedures see Power On the Server on page 153 Hard Drive Device Identifiers TABLE Physical Drive Locations FRU Names and Default Drive Path Names on page 79 lists physical drive locations and their corresponding default path names in OpenBoot PROM and Solaris for the SPARC Enterprise T5440 server TABLE Physical Drive Locations FRU Names and Default Drive Path Names Device Device Identifier OpenBoot PROM Solaris Default Drive Path Name HDDO SYS HDDO c0 dsk d1t0d0 HDD1
85. ceable Units 95 PCIe Device Identifiers TABLE PCle Device Identifiers on page 96 describes device and device identifiers for PCIe cards Device identifiers are case sensitive TABLE PCle Device Identifiers Device Device Identifier Notes PClIe0 SYS MB PCIEO x8 slot PCle1 SYS MB PCIE1 x16 slot operating at x8 PCIe2 SYS MB PCIE2 x8 slot PClIe3 SYS MB PCIE3 x8 slot PCle4 SYS MB PCIE4 or x8 slot shared with XAUI slot XAUIO SYS MB XAUIO PCle5 SYS MB PCIE5 or x8 slot shared with XAUI slot XAUI1 SYS MB XAUI1 PCle6 SYS MB PCIE6 x16 slot operating at x8 PCIe7 SYS MB PCIE7 x8 slot Note PCIe names in ILOM messages are displayed with the full FRU name such as SYS MB PCIEO Note In the Solaris OS PCIe slot addresses are associated with CMP modules The PCIe slot address in the Solaris OS might change if you add or remove CMP modules or if a CMP module is brought offline For more information see the SPARC Enterprise T5440 Server Product Notes Related Information m Managing Faults on page 9 m PCIe Slot Configuration Guidelines on page 97 a System Bus Topology on page 162 m Performing Node Reconfiguration on page 155 96 SPARC Enterprise T5440 Server Service Manual July 2009 PCIe Slot Configuration Guidelines Use the guidelines in TABLE Supported CMP Memory Module Configurations on page 104 to spread the load evenly across CMP memory modules If a slot is alre
86. ch you previously disabled using the enablecomponent command sc gt enablecomponent SYS MB MEMx CMPx BR0 CHO D1 sc gt enablecomponent SYS MB MEMx CMPx BR0 CHO D2 sc gt enablecomponent SYS MB MEMx CMPx BR1 CH1 D3 where x is the CMP memory module to be enabled Performing Node Reconfiguration 161 CODE EXAMPLE Using the enablecomponent command to enable all FB DIMMs on CMP1 on page 162 shows how to enable all the FB DIMMs on MEM1 CODE EXAMPLE Using the enablecomponent command to enable all FB DIMMs on CMP1 sce sco sc gt sc gt sc gt sco sc gt sc gt sc gt sce sce enablecomponent enablecomponent enablecomponent enablecomponent enablecomponent enablecomponent enablecomponent enablecomponent enablecomponent enablecomponent enablecomponent SYS MB MEM1 CMP1 BR0 CH0 D1 SYS MB MEM1 CMP1 BRO0 CH0 D2 SYS MB MEM1 CMP1 BR0 CH0 D3 SYS MB MEM1 CMP1 BR0 CH1 D1 SYS MB MEM1 CMP1 BRO0 CH1 D2 SYS MB MEM1 CMP1 BR0 CH1 D3 SYS MB MEM1 CMP1 BR1 CH0 D1 SYS MB MEM1 CMP1 BR1 CH0 D2 SYS MB MEM1 CMP1 BR1 CH0 D3 SYS MB MEM1 CMP1 BR1 CH1 D1 SYS MB MEM1 CMP1 BR1 CH1 D2 sc gt SYS MB MEM1 CMP1 BR1 CH1 D3 enablecomponent Vv Reset the LDoms Guest Configuration After reconfiguring the I O and PCle fabric you must recreate your LDoms guest configurations as hardware resources that had been previously assigned to your guests might no longer be available 1 Power off the system 2 In t
87. cts abridged POST output CODE EXAMPLE Initiating POST With a Power Cycle gt stop SYS Are you sure you want to stop SYS y n y Stopping gt start SYS SYS Are you sure you want to start SYS y n y Starting SYS CODE EXAMPLE POST Output Abridged gt start SP console 2007 12 1 BCM5466R 2007 12 1 Port 2 2007 12 1 2007 12 1 Port 3 2007 12 1 Loopback 2007 12 1 Port 3 2007 12 1 L9 22 01 17 810 0 0 PHY level Loopback L9 22 01 22 534 0 0 l9 22 01 Test Lo 22301 L9 22 01 9 22 01 9 22 01 22 22 2 27 T5440 No Keyboard to return to ALOM Enter 2007 12 1 2007 12 1 BCM5466R OpenBoot 2007 12 1 2007 12 11 Ethernet L9 22 01 32 012 0 0 L9 22 01 27 274 0 0 7968 MB memory available 22 32 553 542 556 004 271 O gt INFO STATUS Running RGMII 1G Test O gt End Neptune 1G Loopback Test 20 gt 0 gt Begin Neptune 1G Loopback Test 0 gt INFO STATUS Running BMAC level 0 gt End Neptune 1G Loopback Test 20 gt O gt INFO O gt INFO STATUS Running RGMII 1G PHY level Loopback Test Serial 75916434 19 22 01 32 019 0 0 0 gt POST Passed all devices stacie obp 0 l9 22 01 address 2007 12 1 0 ok L9 22 01 232 028 0 0 0 gt POST Return to VBSC 0 14 4 86 64 92 Host ID xxxxx 232 036 0 0 0 gt Master set ACK for vbsc runpost command and spin Manag
88. d 135 v Install the Motherboard 138 Motherboard Fastener Locations 139 Servicing the Flex Cable Assembly 140 v Remove the Flex Cable Assembly 141 v Install the Flex Cable Assembly 142 Servicing the Front Control Panel 144 v Remove the Front Control Panel 144 v Install the Front Control Panel 145 Servicing the Front I O Board 146 v Remove the Front I O Board 147 SPARC Enterprise T5440 Server Service Manual July 2009 v Install the Front I O Board 148 Returning the Server to Operation 149 v Install the Top Cover 150 v Install the Server Into the Rack 150 v Slide the Server Into the Rack 151 v Connect the Power Cords to the Server 153 v Power On the Server 153 Performing Node Reconfiguration 155 I O Connections to CMP Memory Modules 156 Recovering from a Failed CMP Memory Module 157 Reconfiguring I O Device Nodes 158 v Reconfigure the I O and PCIe Fabric 158 v Temporarily Disable All Memory Modules 160 v Re Enable All Memory Modules 161 v Reset the LDoms Guest Configuration 162 System Bus Topology 162 I O Fabric in 2P Configuration 164 I O Fabric in 4P Configuration 165 Connector Pinouts 167 Serial Management Port Connector Pinouts 167 Network Management Port Connector Pinouts 168 Serial Port Connector Pinouts 169 USB Connector Pinouts 169 Gigabit Ethernet Connector Pinouts 170 Server Components 173 Customer Replaceable Units 174 Contents xi Field Replaceable Units 176 Index 179 xii SPARC Enterprise T
89. e the specified FRU may not be faulty Contact service support to isolate the problem gt show faulty Target Property Value PEE ee Geese PE toa ite ee a ep Ea oe ete ect th SP faultmgmt 0 fru SYS IOX X0TC IOB1 LINK SP faultmgmt 0 timestamp Feb 05 18 28 20 SP faultmgmt 0 timestamp Feb 05 18 28 20 faults 0 SP faultmgmt 0 sp_detected_fault Ext FRU SYS IOX X0TC IOB1 LINK faults 0 SIGCON 0 I2C no device response Detecting Faults Using Solaris OS Files and Commands With the Solaris OS running on the server you have the full complement of Solaris OS files and commands available for collecting information and for troubleshooting If POST ILOM or the Solaris PSH features do not indicate the source of a fault check the message buffer and log files for notifications for faults Hard drive faults are usually captured by the Solaris message files Use the dmesg command to view the most recent system message To view the system messages log file view the contents of the var adm messages file Managing Faults 35 36 Related Information m Diagnostic Flowchart on page 11 m Detecting Faults Using LEDs on page 30 a ILOM to ALOM CMT Command Reference on page 53 m SPARC Enterprise T5440 Server Installation and Setup Guide m SPARC Enterprise T5440 Server Administration Guide m Integrated Lights Out Manager 3 0 Supplement for SPARC Enterprise T5440 Server Check the Message Bu
90. e 35 m SPARC Enterprise T5440 Server Installation and Setup Guide m SPARC Enterprise T5440 Server Administration Guide m Integrated Lights Out Manager 3 0 Supplement for SPARC Enterprise T5440 Server ALOM CMT Compatibility Shell Overview The default shell for the service processor is the ILOM shell However you can use the ALOM CMT compatibility shell to emulate the ALOM CMT interface supported on the previous generation of CMT servers Using the ALOM CMT compatibility shell with a few exceptions you can use commands that resemble the commands of ALOM CMT The service processor sends alerts to all ALOM CMT users that are logged in sends the alert through email to a configured email address and writes the event to the ILOM event log The ILOM event log is also available using the ALOM CMT compatibility shell See the Integrated Lights Out Manager 3 0 Supplement for SPARC Enterprise T5440 Server for comparisons between the ILOM CLI and the ALOM CMT compatibility CLI and for instructions for adding an ALOM CMT account Related Information m Diagnostic Flowchart on page 11 m Detecting Faults Using LEDs on page 30 m ILOM to ALOM CMT Command Reference on page 53 m SPARC Enterprise T5440 Server Installation and Setup Guide m SPARC Enterprise T5440 Server Administration Guide m Integrated Lights Out Manager 3 0 Supplement for SPARC Enterprise T5440 Server Solaris Predictive Self Healing Overview The Solaris Predict
91. e ILOM show components Command 24 v Display Individual Component Information With the ILOM show Command 25 Controlling How POST Runs 26 v Change POST Parameters 27 v Run POST in Maximum Mode 28 Detecting Faults 30 Detecting Faults Using LEDs 30 Detecting Faults Using ILOM show faultyCommand 32 v Detect Faults Using the ILOM show faulty Command 33 Detecting Faults Using Solaris OS Files and Commands 35 v Check the Message Buffer 36 v View System Message Log Files 36 Detecting Faults Using the ILOM Event Log 37 v View ILOM Event Log 37 Detecting Faults Using SunVTS Software 38 v Verify Installation of SunVTS Software 38 v Start the SunVTS Browser Environment 39 SunVTS Software Packages 41 Useful SunVTS Tests 42 Detecting Faults Using POST 42 Identifying Faults Detected by PSH 44 vi SPARC Enterprise T5440 Server Service Manual July 2009 v Detect Faults Identified by the Solaris PSH Facility Using the I LOM fmdump Command 45 Clearing Faults 47 v Clear Faults Detected During POST 48 v Clear Faults Detected by PSH 49 v Clear Faults Detected in the External I O Expansion Unit 50 Disabling Faulty Components 50 v Disable System Components 52 v Re Enable System Components 52 ILOM to ALOM CMT Command Reference 53 Preparing to Service the System 59 Safety Information 59 Safety Symbols 60 Electrostatic Discharge Safety Measures 61 Antistatic Wrist Strap 61 Antistatic Mat 61 Required Tools 62 v Obtain the Chassis Serial Number 62
92. e Server Into the Rack on page 151 Servicing Field Replaceable Units 117 If you performed any additional service procedures see Power On the Server on page 153 Servicing the DVD ROM Drive You must remove the front bezel before servicing the DVD ROM drive Related Information Servicing the Front Bezel on page 115 V Remove the DVD ROM Drive Before you begin complete these tasks Read the section Safety Information on page 59 Power off the server using one of the methods described in the section Powering Off the System on page 63 Extend the Server to the Maintenance Position on page 66 Perform Electrostatic Discharge Antistatic Prevention Measures on page 69 Remove the Top Cover on page 69 Remove the Front Bezel on page 116 Do the following 1 Remove the flex cable retainer Loosen the captive No 2 Phillips screw and lift the retainer up and out of the chassis Unplug the DVD ROM drive from the flex cable assembly Push the DVD ROM drive forward until it protrudes from the front of the chassis 118 SPARC Enterprise T5440 Server Service Manual July 2009 FIGURE Removing the DVD ROM Drive 4 Slide the DVD ROM drive out of the chassis V Install the DVD ROM Drive 1 Slide the DVD ROM drive into its bay FIGURE Installing the DVD ROM Drive 2 Connect the DVD ROM drive to the fl
93. e ee eee SP faultmgmt 0 fru SYS MB CPU0 CMP0 BRO CH1 D0 108 SPARC Enterprise T5440 Server Service Manual July 2009 7SP faultmgmt 0 timestamp Dec 14 22 43 59 SP faultmgmt 0 sunw msg id SUN4V 8000 Dx faults 0 SP faultmgmt 0 uuid 3aa7c854 9667 e176 efe5 e487e520 faults 0 7a8a SP faultmgmt 0 timestamp Dec 14 22 43 59 faults 0 m Ifthe show faulty command does not report a fault with a UUID then you do not need to proceed with the following step because the fault is cleared 6 Run the set command gt set SYS MB CPU0 CMP0 BRO CH1 D0 clear_fault_action True Are you sure you want to clear SYS MB CPU0 CMP0 BRO CH1 D0 y n y Set clear_fault_action to true Vv Add FB DIMMs If you are upgrading the system with additional FB DIMMs use this procedure Before you begin complete these tasks m Read the section Safety Information on page 59 m Read the sections Supported FB DIMM Configurations on page 110 and FB DIMM Device Identifiers on page 112 m Power off the server using one of the methods described in the section Powering Off the System on page 63 m Extend the Server to the Maintenance Position on page 66 m Perform Electrostatic Discharge Antistatic Prevention Measures on page 69 m Remove the Top Cover on page 69 m Remove a CMP Memory Module on page 99 1 Unpackage the FB DIMMs and place them on
94. e replacing faulty motherboard you must set diag_mode to normal or off before performing this procedure Related Information a Controlling How POST Runs on page 26 m Servicing CMP Memory Modules on page 98 m Servicing PCIe Cards on page 92 m Servicing the Service Processor on page 120 m Servicing the Fan Tray Carriage on page 129 m Motherboard Fastener Locations on page 139 Remove the Motherboard Before you begin complete these tasks m Read the section Safety Information on page 59 m Power off the server using one of the methods described in the section Powering Off the System on page 63 m Disconnect Power Cords From the Server on page 65 m Remove the Server From the Rack on page 67 m Perform Electrostatic Discharge Antistatic Prevention Measures on page 69 m Remove the Top Cover on page 69 m Remove a PCle Card on page 93 Note You must remove all PCIe cards Note the location of all PCIe cards so you can install them in the correct slots during reassembly m Remove the Service Processor on page 120 m Remove a CMP Memory Module on page 99 Note You must remove all CMP and memory modules Servicing Field Replaceable Units 135 m Remove a Fan Tray on page 83 Note You must remove all four fan trays m Remove the Fan Tray Carriage on page 129 1 Remove the CMP memory module br
95. e sensitive The FB DIMM address follows the same convention as the CMP or memory module upon which it is mounted For example SYS MB CPU0 CMP0 BR1 CHO D0 is the device identifier for the FB DIMM mounted at J792 on CMP module 0 TABLE FB DIMM Configurations and Device Identifiers Connector Location FB DIMM Device Identifiers Number FB DIMM Group CMP module SYS MB CPUx CMPx BR1 CH0 D0 J792 Group 1 SYS MB CPUx CMPx BR1 CH1 D0 J896 4 FB DIMMs SYS MB CPUx CMPx BRO CH0 D0O J585 SYS MB CPUx CMPx BRO CH1 D0 J687 Motherboard connector Memory module SYS MB MEMx CMPx BR1 CH1 D2 J1471 Group 2 SYS MB MEMx CMPx BR1 CH1 D3 J1573 4 FB DIMMs SYS MB MEMx CMPx BR1 CH0 D2 J1066 SYS MB MEMx CMPx BR1 CH0 D3 J1167 SYS MB MEMx CMPx BRO CH1 D2_ J847 Group 3 SYS MB MEMx CMPx BRO CH1 D3 J948 8 FB DIMMs SYS MB MEMx CMPx BRO CH0 D2 J660 SYS MB MEMx CMPx BRO CH0 D3_ J762 SYS MB MEMx CMPx BRO CH1 D1_ J746 SYS MB MEMx CMPx BRO CH0 D1_ J511 SYS MB MEMx CMPx BR1 CH0 D1_ J927 SYS MB MEMx CMPx BR1 CH1 D1_ J1344 Motherboard connector Minimum configuration Related Information m Managing Faults on page 9 m Supported FB DIMM Configurations on page 110 m FB DIMM Fault Button Locations on page 113 m Performing Node Reconfiguration on page 155 112 SPARC Enterprise T5440 Server Service Manual July 2009 FB DIMM Fault Button Locations FIGURE FB DIMM Fault Button Locations on page
96. ecessary use a pen or pencil to press the Power button 64 SPARC Enterprise T5440 Server Service Manual July 2009 Vv Power Off Emergency Shutdown File system corruption might occur M Caution All applications and files will be closed abruptly without saving changes Press and hold the Power button for four seconds V Disconnect Power Cords From the Server Unplug all power cords from the server unplug the power cords before accessing any cold serviceable components A Caution Because 3 3v standby power is always present in the system you must Extending the Server to the Maintenance Position The following components can be serviced with the server in the maintenance position Fan trays CMP memory modules FB DIMMs PCle XAUI cards Service processor Power supply backplane Hard drive backplane Related Information Front Panel Diagram on page 3 Rear Panel Diagram on page 5 Extend the Server to the Maintenance Position on page 66 Preparing to Service the System 65 V Extend the Server to the Maintenance Position 1 Optional Use the set SYS LOCATE command from the gt prompt to locate the system that requires maintenance gt set SYS LOCATE value Fast_Blink Once you have located the server press the Locator LED and button to turn it off 2 Verify that no cables will be damaged or will interfere when the server is extended Although the cable mana
97. ed All SPARC trademarks are used under license and are registered trademarks of SPARC International Inc in the U S and other countries Products bearing SPARC trademarks are based upon architecture developed by Sun Microsystems Inc SPARC64 is a trademark of SPARC International Inc used under license by Fujitsu Microelectronics Inc and Fujitsu Limited SSH is a registered trademark of SSH Communications Security in the United States and in certain other jurisdictions The OPEN LOOK and Sun Graphical User Interface was developed by Sun Microsystems Inc for its users and licensees Sun acknowledges the pioneering efforts of Xerox in researching and developing the concept of visual or graphical user interfaces for the computer industry Sun holds a non exclusive license from Xerox to the Xerox Graphical User Interface which license also covers Sun s licensees who implement OPEN LOOK GUIs and otherwise comply with Sun s written license agreements United States Government Rights Commercial use U S Government users are subject to the standard government user license agreements of Sun Microsystems Inc and Fujitsu Limited and the applicable provisions of the FAR and its supplements Disclaimer The only warranties granted by Fujitsu Limited Sun Microsystems Inc or any affiliate of either of them in connection with this document or any product or technology described herein are those expressly set forth in the license agreement pursu
98. ed any additional service procedures see Power On the Server on page 153 82 SPARC Enterprise T5440 Server Service Manual July 2009 V Remove a Fan Tray If you are removing the fan trays as a prerequisite for another service procedure follow the steps in this procedure Before you begin complete these tasks m Read the section Safety Information on page 59 m Power off the server using one of the methods described in the section Powering Off the System on page 63 m Perform the task Extend the Server to the Maintenance Position on page 66 m Perform the task Perform Electrostatic Discharge Antistatic Prevention Measures on page 69 Do the following Press the fan tray latches toward the center of the fan tray and pull the fan tray up and out of the system FIGURE Removing a Fan Tray Servicing Customer Replaceable Units 83 V Install a Fan Tray 1 Slide each fan tray into its bay until it locks into place Ensure that the fan tray is oriented correctly Airflow in the system is from front to back 2 Verify proper fan tray operation See Fan Tray Fault LED on page 84 Next Steps If you are replacing the fan trays after performing another service procedure complete these steps m Slide the Server Into the Rack on page 151 m Power On the Server on page 153 Fan Tray Device Identifiers TABLE Fan Tray Device Identifiers on page 84 describes the
99. em Excerciser 40 tests 42 user interfaces 38 39 41 42 using for fault diagnosis 12 verifying installation 38 syslogd daemon 36 system bus topology 162 system console 23 system console switching to 23 system controller 10 184 SPARC Enterprise T5440 Server Service Manual July 2009 T tools required for service 62 Top system LED about 5 top cover and emergency shutdown 150 installing 150 troublehooting CMP1 failure 156 troubleshooting AC OK LED state 12 actions 12 by checking Solaris OS log files 12 CMP0 failure 156 FB DIMMs 22 Power OK LED state 12 using LEDs 30 using POST 13 14 using SunVTS 12 using the show faulty command 12 U UltraSPARC T2 multicore processor 18 Universal Unique Identifier UUID 18 45 USB ports pinouts 169 USB ports front 3 vV virtual keyswitch 28 107 X XAUI card about 1 configuration guidelines see PCIe configuration guidelines installing See PCIe card installing Index 185 186 SPARC Enterprise T5440 Server Service Manual July 2009 cO FUJITSU
100. es such as manufacturer model number serial number size and system error statistics CODE EXAMPLE Sample Ap_id Output Ap_id Type co scsi bus c0 dsk d1t0d0 disk c0 sdl1 disk usb0 1 unknown usb0 2 unknown usb0 3 unknown usb1 1 unknown usb1 2 unknown usb1 3 unknown usb2 1 unknown usb2 2 unknown usb2 3 unknown usb2 4 unknown usb2 5 unknown usb2 6 unknown usb2 7 unknown usb2 8 unknown emp emp emp emp emp emp emp emp emp emp emp emp emp emp Receptacle connected connected connected cy cy cy cy cy cy cy cy cy cy cy cy cy cy Occupant configured configured uncon figured unconfigured uncon figured unconfigured uncon uncon uncon uncon uncon uncon uncon uncon figured figured figured figured figured figured figured figured unconfigured uncon figured unconfigured Condition unknown unknown unknown ok ok ok ok ok ok ok ok ok ok ok ok ok ok V Remove a Hard Drive If you are removing a hard drive as a prerequisite for another service procedure follow the steps in this section Before you begin complete these tasks m Read the section Safety Information on page 59 m Power off the server using one of the methods described in the section Powering Off the System on page 63 m Perform Electrostatic Discharge Antistatic Prevention Measures on page 69 Do the following 1 Note the lo
101. ex cable assembly 3 Install the flex cable retainer Place the retainer into position and tighten the captive No 2 Phillips screw Servicing Field Replaceable Units 119 Next Steps m Install the Front Bezel on page 117 m Install the Top Cover on page 150 m Slide the Server Into the Rack on page 151 m Power On the Server on page 153 Servicing the Service Processor The service processor module contains the service processor firmware IDPROM and system battery Related Information m Servicing the IDPROM on page 123 m Servicing the Battery on page 125 V Remove the Service Processor Before you begin complete these tasks m Read the section Safety Information on page 59 m Power off the server using one of the methods described in the section Powering Off the System on page 63 m Extend the Server to the Maintenance Position on page 66 m Disconnect Power Cords From the Server on page 65 m Perform Electrostatic Discharge Antistatic Prevention Measures on page 69 m Remove the Top Cover on page 69 Do the following 1 Ensure that the power cords are disconnected from the server 2 Loosen the two captive No 2 Phillips screws securing the service processor to the motherboard 120 SPARC Enterprise T5440 Server Service Manual July 2009 FIGURE Removing the Service Processor 3 Lift the service processor up and out of the system
102. f SunVTS packages using the pkginfo command pkginfo 1 SUNWvts SUNWvtsmn SUNWvtsr SUNWvtss SUNWvtsts m If the SunVTS software is installed information about the packages is displayed m If the SunVTS software is not installed you see an error message for each missing package as in CODE EXAMPLE Missing Package Errors for SunVTS Software on page 39 See TABLE SunVTS Software Packages on page 41 for a list of required SunVTS software packages 2 If the SunVTS software is not installed you can obtain the installation packages from the following places m Solaris Operating System DVDs m Download from the web Refer to the Preface for information on how to access the web site CODE EXAMPLE Missing Package Errors for SunVTS Software ERROR information for SUNWvts was not found ERROR information for SUNWvtsr was not found V Start the SunVTS Browser Environment For information about test options and prerequisites refer to the SunVTS 7 0 User s Guide Note SunVTS software can be run in several modes You must perform this procedure using the default mode 1 Start the SunVTS agent and Javabridge on the server cd usr sunvts bin startsunvts 2 At the interface prompt choose C to start the SunVTS client Managing Faults 39 40 3 Start the SunVTS browser environment from a web browser on the client system Type https server name 6789 The SunVTS browser environme
103. f the server Related Information a Diagnostic Flowchart on page 11 m SPARC Enterprise T5440 Server Installation and Setup Guide m SPARC Enterprise T5440 Server Administration Guide 10 SPARC Enterprise T5440 Server Service Manual July 2009 Diagnostic Flowchart FIGURE Diagnostic Flowchart on page 11 is a flowchart of the diagnostics available to troubleshoot faulty hardware TABLE ILOM Parameters Used for POST Configuration on page 26 has more information about each diagnostic in this chapter FIGURE Diagnostic Flowchart 1 Are the Check the Power OK and power source AC OK LEDs and off connections Faulty hardware suspected 2 Are any faults reported by the ILOM show faulty command displays a Identify faulty FRU from the fault message and replace the FRU or ILOPM event log fault an External I O Expansion Unit fault Identify faulty FRU from the 4 Does Sun VTS Sun VTS report message and any faulty replace the devices er ii Jis fault 8 Is the Yes Identify faulty 5 Does FRU from the POST report any faulty and replace devices the FRU 9 The fault is a POST detected fault 10 Contact Sun Support if the fault condition persists Numbers in this flow chart correspond to the Action numbers in Table 2 1 Identify the fault condition from the fault message
104. ffer 1 Log in as superuser 2 Issue the dmesg command dmesg The dmesg command displays the most recent messages generated by the system View System Message Log Files The error logging daemon syslogd automatically records various system warnings errors and faults in message files These messages can alert you to system problems such as a device that is about to fail The var adm directory contains several message files The most recent messages are in the var adm messages file After a period of time usually every week a new messages file is automatically created The original contents of the messages file are rotated to a file named messages 1 Over a period of time the messages are further rotated to messages 2 and messages 3 and then deleted 1 Log in as superuser 2 Type the following command more var adm messages 3 If you want to view all logged messages type the following command more var adm messages SPARC Enterprise T5440 Server Service Manual July 2009 Detecting Faults Using the ILOM Event Log Certain problems are recorded in the ILOM event log but not posted to the list of faults displayed by the ILOM show faulty command Inspect the ILOM event log if you suspect a problem but no entry appears in the ILOM show faulty command output Related Information a Diagnostic Flowchart on page 11 m View ILOM Event Log on page 37 a ILOM to AL
105. formation m Servicing Hard Drives on page 72 m Servicing Fan Trays on page 81 m Servicing Power Supplies on page 85 m Server Components on page 173 Servicing Hard Drives The hard drives in the server are hot pluggable but this capability depends on how the hard drives are configured To hot plug a drive you must take the drive offline before you can safely remove it Taking a drive offline prevents any applications from accessing it and removes the logical software links to it 72 SPARC Enterprise T5440 Server Service Manual July 2009 Caution You must use hard drives designed for this server which have a vented front panel to allow adequate airflow to internal system components Installing inappropriate hard drives could result in an overtemperature condition The following situations inhibit your ability to hot plug a drive m If the hard drive contains the operating system and the operating system is not mirrored on another drive m If the hard drive cannot be logically isolated from the online operations of the server If your drive falls into one of these conditions you must power off the server before you replace the hard drive Related Information m Identifying Server Components on page 1 m Managing Faults on page 9 m Powering Off the System on page 63 a Hot Pluggable and Hot Swappable Devices on page 72 m Hard Drive Device Identifiers on page 79
106. g 1 2 Identify the module you want to remove Rotate the ejector levers up and away from the module Servicing Customer Replaceable Units 99 FIGURE Removing a CMP Module PELELEL og oy FN UCU Gir a W i 3 Slide the module up and out of the system 4 Place the module on an antistatic mat Vv Install a CMP Memory Module Note If you are replacing a faulty CMP or memory module you must transfer the FB DIMMs on the faulty module to the replacement module Replacement CMP memory modules do not include FB DIMMs For more information about installing FB DIMMs see Servicing FB DIMMs on page 104 1 Identify the correct slot for installation 100 SPARC Enterprise T5440 Server Service Manual July 2009 FIGURE 2 Slide the module down into its slot Installing a CMP Memory Module 3 Rotate the ejector levers down to secure the module into place Next Steps Install the Top Cover on page 150 Slide the Server Into the Rack on page 151 Power On the Server on page 153 v Add a CMP Memory Module Before you begin complete these tasks Read the section Safety Information on page 59 Power off the server using one of the methods described in the section Powering Off the System on page 63 Extend the Server to the Maintenance Position on page 66 Perform Electrostatic Discharge Antistatic Prevention Measures on p
107. gement arm CMA that is supplied with the server is hinged to accommodate extending the server you should ensure that all cables and cords are capable of extending 3 From the front of the server release the two slide release latches FIGURE Extending the Server Into the Maintenance Position on page 66 Squeeze the slide rail locks to release the slide rails FIGURE Extending the Server Into the Maintenance Position Figure Legend 1 Slide Rail Lock 2 Inner Rail Release Button 66 SPARC Enterprise T5440 Server Service Manual July 2009 4 While squeezing the slide rail locks slowly pull the server forward until it is locked in the service position Removing the Server From the Rack The server must be removed from the rack to remove or install the following components m Motherboard Caution Two people must dismount and carry the chassis FIGURE Lift Warning Related Information m Front Panel Diagram on page 3 m Rear Panel Diagram on page 5 m Extend the Server to the Maintenance Position on page 66 m Remove the Server From the Rack on page 67 Remove the Server From the Rack 1 Disconnect all the cables and power cords from the server 2 Extend the server to the maintenance position See Extending the Server to the Maintenance Position on page 65 Preparing to Service the System 67 3 Disconnect the CMA Pull out the retention pin that secures the ca
108. he ALOM compatibility shell type sc gt bootmode config factory default 3 Power on the system 4 Recreate your LDoms guests using the remaining hardware resources System Bus Topology FIGURE System Bus Topology on page 163 describes the system bus topology for the SPARC Enterprise T5440 server 162 SPARC Enterprise T5440 Server Service Manual July 2009 FIGURE System Bus Topology Related Information m I O Fabric in 2P Configuration on page 164 m I O Fabric in 4P Configuration on page 165 Performing Node Reconfiguration 163 164 I O Fabric in 2P Configuration TABLE Devices controlled by CMPs in 2P systems CMP Number Devices Controlled CMPO0 Onboard disk drives Onboard USB ports Onboard DVD drive PCIe0 PCIe1 PClIe2 PClIe3 CMP1 Onboard Gbit or 10 Gbit network PCle4 PClIe5 PClIe6 PCle7 Related Information a System Bus Topology on page 162 m I O Fabric in 4P Configuration on page 165 SPARC Enterprise T5440 Server Service Manual July 2009 I O Fabric in 4P Configuration TABLE Devices controlled by CMPs in 4P systems CMP Number Devices Controlled CMPO0 Onboard disk drives Onboard USB ports Onboard DVD drive PCTe0 PCIe1 CMP1 Onboard Gbit or 10 Gbit network PCle4 PCIe5 CMP2 PClIe2 PCIe3 CMP3 PCle6 PCle7 Related Information m System Bus Topology on page 162 m I
109. he four 10 100 1000 Mbps Ethernet ports each have two LEDs as described in TABLE Ethernet Port LEDs on page 8 TABLE Ethernet Port LEDs LED Color Description Left LED Amber Speed indicator or e Amber on The link is operating as a Gigabit connection green 1000 Mbps e Green on The link is operating as a 100 Mbps connection e Off The link is operating as a 10 Mbps connection Right LED Green Link Activity indicator e Steady on A link is established e Blinking There is activity on this port e Off No link is established The NET MGT port only operates in 100 Mbps or 10 Mbps so the speed indicator LED will be green or off never amber Related Information m Rear Panel Diagram on page 5 m Rear Panel LEDs on page 7 m Detecting Faults Using LEDs on page 30 8 SPARC Enterprise T5440 Server Service Manual July 2009 Managing Faults These topics describe the diagnostics tools that are available for monitoring and troubleshooting the server This chapter is intended for technicians service personnel and system administrators who service and repair computer systems Topic Links Background fault detection methodology Configuring and using the service processor Displaying system configuration information with the service processor Configuring POST for diagnostic purposes Detecting system faults Clearing system faults Disabling faulty component
110. he rail s bracket The inner slide assemblies should be locked past the internal stop See FIGURE Inserting the System Into the Rack on page 151 Ensure that the ball bearing retainer is locked all the way forward 150 SPARC Enterprise T5440 Server Service Manual July 2009 FIGURE Inserting the System Into the Rack 2 Lift the server up and insert the inner rails into the inner slide assemblies Ensure that the inner rails are horizontal when the inner rails enter the inner slide assemblies 3 Ensure that the inner rails are engaged with the ball bearing retainers on both inner slide assemblies Note If necessary support the server with the mechanical lift while aligning the inner rails parallel to the rack mounted inner slide assemblies YV Slide the Server Into the Rack 1 Press the inner rail release buttons FIGURE Slide Rail Release Button Location on page 152 on both sides of the server Returning the Server to Operation 151 FIGURE Slide Rail Release Button Location Figure Legend 1 Inner rail release button 2 Slide rail lock 2 While pushing on the release buttons slowly push the server into the rack Ensure that the cables do not get in the way 3 If necessary re attach the CMA a Attach the CMA support strut to the inner glide b Attach the CMA to the inner glide Slide the hinge plate into the end of the outer rail until the retaining pin snaps into place 4
111. he service processor Ensure that the service processor is oriented correctly A notch on the IDPROM corresponds to a similar notch on the connector Servicing the Battery The battery provides the power necessary to maintain system configuration parameters during power outages or while the system is being serviced stored or relocated Related Information Servicing the Service Processor on page 120 Servicing the IDPROM on page 123 V Remove the Battery Before you begin complete these tasks Read the section Safety Information on page 59 Power off the server using one of the methods described in the section Powering Off the System on page 63 Extend the Server to the Maintenance Position on page 66 Disconnect Power Cords From the Server on page 65 Perform Electrostatic Discharge Antistatic Prevention Measures on page 69 Remove the Top Cover on page 69 Remove the Service Processor on page 120 Release the latch securing the battery to its holder on the service processor board Lift the battery up and off the board V Install the Battery 1 Place the battery into its holder on the service processor board Ensure that the battery is oriented correctly Servicing Field Replaceable Units 125 2 Press the battery firmly until it snaps into place Next Steps m Install the Service Processor on page 122 m Install the Top Cover on page 1
112. illips screw 5 Remove the two 7 mm hex nuts securing the bus bars to the power distribution board FIGURE Disconnecting the Power Distribution Board From the Chassis 6 Slide the power distribution board up and out of the chassis Servicing Field Replaceable Units 127 V Install the Power Distribution Board 1 Align the keyholes in the power distribution board with the corresponding mushroom standoffs in the chassis 2 Lower the power distribution board into the chassis FIGURE Installing the Power Distribution Board 3 Install the No 2 Phillips screw 4 Install the two 7 mm nuts securing the bus bars to the power distribution board 5 Plug in the flex cable connector Ensure that the auxilliary power cable is routed under the flex cable connector 6 Plug in the auxiliary power cable 7 Install the flex cable retainer Place the retainer into position and tighten the captive No 2 Phillips screw Next Steps m Install the Top Cover on page 150 m Slide the Server Into the Rack on page 151 a Install a Power Supply on page 90 Note Install all four power supplies m Connect the Power Cords to the Server on page 153 m Power On the Server on page 153 128 SPARC Enterprise T5440 Server Service Manual July 2009 Servicing the Fan Tray Carriage You must remove the fan tray carriage in order to service the following components m Hard disk backplane Motherboard
113. ing SYS gt start SYS Are you sure you want to start SYS y n y Starting SYS Note In the ILOM shell there is no notification when the system is actually powered off Powering off takes about a minute Use the show HOST command to determine if the host has powered off V Re Enable System Components The component_state property enables a component by removing it from the ASR blacklist 1 At the gt prompt set the component_state property to Enabled gt set SYS MB CPU0 CMP0 BR1 CHO DO component_state Enabled 2 Reset the server so that the ASR command takes effect gt stop SYS Are you sure you want to stop SYS y n y Stopping SYS gt start SYS Are you sure you want to start SYS y n y Starting SYS 52 SPARC Enterprise T5440 Server Service Manual July 2009 Note In the ILOM shell there is no notification when the system is actually powered off Powering off takes about a minute Use the show HOST command to determine if the host has powered off ILOM to ALOM CMT Command Reference TABLE ALOM CMT Parameters and POST Modes on page 56 describes the typical commands for servicing a server For descriptions of all ALOM CMT commands issue the help command or refer to the following documents m Integrated Lights Out Manager 3 0 Concepts Guide m Integrated Lights Out Manager 3 0 Supplement for SPARC Enterprise T5440 Server TABLE Service Re
114. ing log files and ILOM record system events and provide information Solaris OS Files and system event log about faults Commands on page 35 for fault e Browse the ILOM system event log for major or information critical events Some problems are logged in the event log but not added to the show faulty list e If system messages indicate a faulty device replace the FRU e To obtain more diagnostic information go to Action No 4 4 Run SunVTS SunVTS is an application you can run to exercise Detecting Faults Using software and diagnose FRUs To run SunVTS the server must SunVTS Software on be running the Solaris OS page 38 e If SunVTS reports a faulty device replace the FRU e If SunVTS does not report a faulty device go to Action No 5 12 SPARC Enterprise T5440 Server Service Manual July 2009 TABLE Diagnostic Flowchart Actions Continued Action No Diagnostic Action Resulting Action For more information 5 Run POST POST performs basic tests of the server components Detecting Faults Using and reports faulty FRUs POST on page 42 TABLE System Faults and Fault LED States on page 31 TABLE ALOM CMT Parameters and POST Modes on page 56 6 Determine if the Determine if the fault is an environmental fault ora Detecting Faults Using fault is an configuration fault ILOM show faulty environmental or Jf the fault listed by the show faulty command Command on page 32 configuration displays a temperature or voltage fa
115. ing Faults 29 Detecting Faults This section describes the different methods you can use to identify system faults in the SPARC Enterprise T5440 Task Topic Use front panel and back panel LEDs to identify system faults Use the ILOM show faulty command to etect faults se Solaris OS files and commands to d U detect faults U se the ILOM event log to detect faults Use POST to identify faults Use Solaris Predictive Self Healing PSH to identify faults Detecting Faults Using LEDs on page 30 Detecting Faults Using I LOM show faulty Command on page 32 Detecting Faults Using Solaris OS Files and Commands on page 35 Detecting Faults Using the ILOM Event Log on page 37 Detecting Faults Using POST on page 42 Identifying Faults Detected by PSH on page 44 Detecting Faults Using LEDs The server provides the following groups of LEDs m Front panel system LEDs See Front Panel LEDs on page 4 m Rear panel system LEDs See Rear Panel LEDs on page 7 a Hard drive LEDs See Hard Drive LEDs on page 80 a Power supply LEDs See Power Supply LED on page 91 m Fan tray LEDs See Fan Tray Fault LED on page 84 m Rear panel Ethernet port LEDs See Ethernet Port LEDs on page 8 a CMP module or memory module LEDs See Servicing CMP Memory Modules on page 98 a FB DIMM Fault LEDs See FB DIMM Fault Button Locations on
116. ing Off the System on page 63 Extending the Server to the Maintenance Position on page 65 Removing the Server From the Rack on page 67 Removing the Top Cover on page 69 Related Information m Managing Faults on page 9 m Servicing Customer Replaceable Units on page 71 m Servicing Field Replaceable Units on page 115 m Returning the Server to Operation on page 149 Safety Information This section describes important safety information that you need to know prior to removing or installing parts in the SPARC Enterprise T5440 server 59 gt For your protection observe the following safety precautions when setting up your equipment m Follow all cautions and instructions marked on the equipment and described in the documentation shipped with your system m Follow all cautions and instructions marked on the equipment and described in the SPARC Enterprise T5440 Server Safety and Compliance Guide m Ensure that the voltage and frequency of your power source match the voltage and frequency inscribed on the equipment s electrical rating label m Follow the electrostatic discharge safety practices as described in this section Related Information m Safety Symbols on page 60 a Antistatic Wrist Strap on page 61 m Antistatic Mat on page 61 m Perform Electrostatic Discharge Antistatic Prevention Measures on page 69 Safety Symbols Note the me
117. ing the ILOM show faulty Command Atthe gt prompt type the show faulty command The following show faulty command examples show the different kinds of output from the show faulty command m Example of the show faulty command when no faults are present gt show faulty Target Property Managing Faults 33 m Example of the show faulty command displaying an environmental fault gt show faulty Target Property Value Be ieee er Na So hh pete he ER EAE te 8 ee ee E SP faultmgmt 0 fru SYS MB FT1 SP faultmgmt 0 timestamp Dec 14 23 01 32 SP faultmgmt 0 timestamp Dec 14 23 01 32 faults 0 SP faultmgmt 0 sp_detected_fault TACH at SYS MB FT1 has faults 0 exceeded low non recoverable threshold a Example of the show faulty command displaying a configuration fault gt show faulty Target Property Value eee eer ater Serene Peete ee Saw soe ee ea Se ee La er ee SP faultmgmt 0 fru SYS SP faultmgmt 0 timestamp Mar 17 08 17 45 SP faultmgmt 0 timestamp Mar 17 08 17 45 faults 0 SP faultmgmt 0 sp_detected_fault At least 2 power supplies must faults 0 have AC power Note Environmental and configuration faults automatically clear when the environmental condition returns to the normal range of when the configuration fault is addressed a Example showing a fault that was detected by the PSH technology These kinds of faults are d
118. ing the service processor the IDPROM can be transferred to a new board to retain system configuration data Power supply backplane This board distributes main 12V power from the power supplies to the rest of the system The power supply backplane is connected to the motherboard and the disk drive backplane via a flex cable High voltage power is provided to the motherboard via a bus bar assembly Hard drive backplane This board includes the connectors for up to four hard drives It is connected to the motherboard via a flex cable assembly Each drive has its own Power Activity Fault and Ready to Remove LEDs Front control panel This board connects directly to the motherboard and serves as the interconnect for the front I O board It contains the front panel LEDs and the Power button Front I O board This board connects to the front control panel interconnect It contains two USB ports Flex cable assembly The flex cable assembly serves as the interconnect between the power supply backplane motherboard hard drive backplane and DVD ROM drive Power supply backplane I2C cable This cable transmits power supply status to the motherboard Related Information SPARC Enterprise T5440 Server Site Planning Guide Managing Faults on page 9 Servicing Customer Replaceable Units on page 71 Servicing Field Replaceable Units on page 115 SPARC Enterprise T5440 Server Service Manual July 2009
119. ion board 128 power supply 87 90 service processor 122 top cover 150 Integrated Lights Out Manager and fault detection in External I O Expansion Unit 15 iostat Ecommand 77 L latch power supply 86 89 slide rail 66 LED AC Present power supply LED 12 92 DC OK power supply LED 91 Fan Fault system LED 31 Fault fan module LED 31 Fault hard drive LED 31 Fault power supply LED 31 86 92 FB DIMM Fault motherboard LEDs 32 Gigabit Ethernet port 8 Locator 4 7 Overtemp system LED 5 31 Power OK system LED 12 Power Supply Fault system LED 5 31 88 92 Ready to Remove hard drive LED 74 76 Service Required system LED 4 31 92 Top system LED 5 LEDs about 30 fan module 31 fan tray 84 front panel 4 hard drive 80 network management port 8 rear panel 7 Service Required system LED 32 using to diagnose faults 30 using to identify device state 30 Locator LED and button 3 4 5 7 log files viewing 36 logical domains guest configuration 162 M MAC addresses stored on SCC module 2 maintenance position 65 67 memory also see FB DIMMs fault handling 21 memory modules see CMP memory modules message ID 18 messages file 35 motherboard about 1 fastener locations 139 installing 138 removing 135 N network management port LEDs 8 pinouts 168 node reconfiguration 155 and I O services 156 I O device nodes 158 PCIe 158 Normal mode virtual keys
120. isplaying with show command 25 FRU status displaying 25 G Gigabit Ethernet ports LEDs 8 pinouts 170 H hard drive about 72 addressing 75 78 determining fault state 31 device identifiers 79 Fault LED 31 hot plugging 75 installing 75 78 Ready to Remove LED 76 removing 73 77 hard drive backplane 132 about 2 installing 133 removing 132 hard drive LEDs 80 hard drive LEDs about 80 help command 53 host ID stored on SCC module 2 hot pluggable devices 72 hot plugging hard drive 73 75 hard drive situations inhibiting 73 hot swappable devices 72 hot swapping fan tray 81 82 power supply 86 l I O connections to CMP module 156 I O fabric in 2 processor configuration 164 in 4 processor configuration 165 I O subsystem 18 19 51 IDPROM installing 124 removing 123 ILOM commands show 25 show faulty 33 43 55 108 ILOM see Integrated Lights Out Management ILOM ILOM system event log 12 indicators 30 infrastructure boards about 1 See also power distribution board power supply backplane hard drive backplane front I O board front control panel installing 100 battery 125 Index 181 CMP memory module 100 DVD ROM drive 119 fan tray 82 84 fan tray carriage 131 FB DIMMs 105 flex cable assembly 142 front bezel 117 front control panel 145 front I O board 148 hard drive 75 78 hard drive backplane 133 IDPROM 124 motherboard 138 PCIe card 94 power distribut
121. istinguished from other kinds of faults by the presence of a sunw msg id and by a UUID gt show faulty Target Property Value EERE th Eee E E Oe PEN NOTAE SE eae cays bitte herd a lata AL ete te cha ta a SP faultmgmt 0 fru SYS MB MEMO CMP0 BR1 CH1 D1 SP faultmgmt 0 timestamp Dec 14 22 43 59 SP faultmgmt 0 sunw msg id SUN4V 8000 Dx faults 0 SP faultmgmt 0 uuid 3aa7c854 9667 e176 efe5 e487e520 faults 0 l 7a8a SP faultmgmt 0 timestamp Dec 14 22 43 59 faults 0 34 SPARC Enterprise T5440 Server Service Manual July 2009 m Example showing a fault that was detected by POST These kinds of faults are identified by the message Forced fail reason where reason is the name of the power on routine that detected the failure gt show faulty SP faultmgmt 0 SYS MB CPU0 CMP0 BR1 CHO DO SP faultmgmt 0 timestamp Dec 21 16 40 56 SP faultmgmt 0 timestamp Dec 21 16 40 56 faults 0 SP faultmgmt 0 sp_detected_fault SYS MB CPU0 CMP0 CMP0 BR1 CH0 DO faults 0 Forced fail POST m Example showing a fault in the External I O Expansion Unit These faults can be identified by the text string Ext FRU or Ext sensor at the beginning of the fault description The text string Ext FRU indicates that the specified FRU is faulty and should be replaced The text string Ext sensor indicates that the specified FRU contains the sensor that detected the problem In this cas
122. ive Self Healing PSH technology enables the server to diagnose problems while the Solaris OS is running and mitigate many problems before they negatively affect operations Managing Faults 17 The Solaris OS uses the Fault Manager daemon fmd 1M which starts at boot time and runs in the background to monitor the system If a component generates an error the daemon handles the error by correlating the error with data from previous errors and other related information to diagnose the problem Once diagnosed the Fault Manager daemon assigns the problem a Universal Unique Identifier UUID that distinguishes the problem across any set of systems When possible the Fault Manager daemon initiates steps to self heal the failed component and take the component offline The daemon also logs the fault to the syslogd daemon and provides a fault notification with a message ID MSGID You can use the message ID to get additional information about the problem from the knowledge article database The Predictive Self Healing technology covers the following server components m UltraSPARC T2 Plus multicore processor Memory a I O subsystem The PSH console message provides the following information about each detected fault m Type m Severity Description Automated response Impact m Suggested action for system administrator Related Information a Diagnostic Flowchart on page 11 m Identifying Faults Detected by PSH on p
123. l Diagram on page 3 Front Panel LEDs on page 4 Overview of rear panel features Rear Panel Diagram on page 5 Rear Panel LEDs on page 7 Ethernet Port LEDs on page 8 Related Information m Server Components on page 173 Infrastructure Boards and Cables The SPARC Enterprise T5440 server is based on a 4U chassis The SPARC Enterprise T5440 server has the following boards installed in the chassis Motherboard The motherboard includes slots for up to four CMP modules and four memory modules memory control subsystem up to eight PCle expansion slots and a service processor slot The motherboard also contains a top cover safety interlock kill switch Note 10 Gbit Ethernet XAUI cards are shared in Slots 4 and 5 CMP module Each CMP module contains an UltraSPARC T2 Plus chip slots for four FB DIMMs and associated DC DC converters 2 Memory module A memory module containing slots for an additional 12 FB DIMMs is associated with each CMP module Service processor The service processor ILOM board controls the server power and monitors server power and environmental events The service processor draws power from the server s 3 3V standby supply rail which is available whenever the system is receiving main input power even when the system is turned off A removable IDPROM contains MAC addresses host ID and ILOM and OpenBoot PROM configuration data When replac
124. lated Commands ILOM Command ALOM CMT Command Description help command help command Displays a list of all available commands with syntax and descriptions Specifying a command name as an option displays help for that command set HOST send_break_action break y c D Takes the host server from the OS to true e y skips the confirmation either kmdb or OpenBoot PROM question equivalent to a Stop A depending s c executes a consote command ee Solaris software was after the break command Goted completes e D forces a core dump of the Solaris OS set clearfault UUID Manually clears host detected SYS component clear_fault_a faults The UUID is the unique fault ction true ID of the fault to be cleared start SP console console f Connects you to the host system e f forces the console to have read and write capabilities Managing Faults 53 TABLE Service Related Commands Continued ILOM Command ALOM CMT Command Description show SP console history consolehistory b lines e lines v g lines boot run The following options enable you to specify how the output is displayed e g lines specifies the number of lines to display before pausing e lines displays n lines from the end of the buffer b lines displays n lines from the beginning of the buffer e v displays the entire buffer e boot run specifies the log to display run is the default log bootmode value no
125. lt ID UUID and logged PSH reports the fault and identifies the locations of the faulty FB DIMMs If you suspect that the server has a memory problem follow the flowchart see FIGURE Diagnostic Flowchart on page 11 Run the ILOM show faulty command The show faulty command lists memory faults and lists the specific FB DIMMs that are associated with the fault Managing Faults 21 Note You can use the FB DIMM DIAG buttons on the CMP module and memory module to identify faulty FB DIMMs See FB DIMM Fault Button Locations on page 113 Once you identify which FB DIMMs you want to replace see Servicing FB DIMMs on page 104 for FB DIMM removal and replacement instructions You must perform the instructions in that section to clear the faults and enable the replaced FB DIMMs Related Information a Controlling How POST Runs on page 26 a Displaying FRU Information with ILOM on page 24 m Detecting Faults on page 30 m Servicing FB DIMMs on page 104 22 Connecting to the Service Processor Before you can run ILOM commands you must connect to the service processor There are several ways to connect to the service processor Topic Links Connect an ASCII terminal directly to the SPARC Enterprise T5440 Server Installation serial management port and Setup Guide Use the ssh command to connect to service SPARC Enterprise T5440 Server Installation processor through an Ethernet connection a
126. lth of the processor and memory and works with ILOM to take a faulty component offline if needed The Predictive Self Healing technology enables systems to accurately predict component failures and mitigate many serious problems before they occur Log files and console messages Solaris OS log files and ILOM system event log can be accessed and displayed on the device of your choice m SunVTS software The SunVTS software exercises the system provides hardware validation and discloses possible faulty components with recommendations for repair The LEDs ILOM Solaris OS PSH and many of the log files and console messages are integrated For example a fault detected by the Solaris software displays the fault logs it and passes information to ILOM where it is logged Depending on the fault one or more LEDs might be illuminated The diagnostic flowchart in TABLE Diagnostic Flowchart Actions on page 12 and TABLE ILOM Parameters Used for POST Configuration on page 26 describes an approach for using the server diagnostics to identify a faulty field replaceable unit FRU The diagnostics you use and the order in which you use them depend on the nature of the problem you are troubleshooting So you might perform some actions and not others Before referring to the flowchart perform some basic troubleshooting tasks m Verify that the server was installed properly m Visually inspect cables and power Optional Perform a reset o
127. ltmgmt 0 fru SYS IOX X0TC IOB1 LINK SP faultmgmt 0 timestamp Feb 05 18 28 20 SP faultmgmt 0 timestamp Feb 05 18 28 20 faults 0 SP faultmgmt 0 sp_detected_fault Ext FRU SYS IOXQ X0OTC IOB1 LINK faults 0 SIGCON 0 I2C no device response After the problem is repaired use the ILOM set clear_fault_action command to clear a fault in the External I O Expansion Unit gt set clear_fault_action true SYS IOX X0TC IOB1 LINK Are you sure you want to clear SYS IOX X0TC IOB1 LINK y n y Set clear_fault_action to true Disabling Faulty Components You can use the Automatic System Recovery ASR feature to configure the server to automatically disable failed components until they can be replaced The following components are managed by the ASR feature m UltraSPARC T2 Plus processor strands Memory FB DIMMs 50 SPARC Enterprise T5440 Server Service Manual July 2009 m I O subsystem The database that contains the list of disabled components is referred to as the ASR blacklist asr db In most cases POST automatically disables a faulty component After the cause of the fault is repaired FRU replacement loose connector reseated and so on you might need to remove the component from the ASR blacklist Note For instructions on enabling or disabling ASR see the SPARC Enterprise T5440 Server Administration Guide The ASR commands TABLE ASR Commands on page
128. n complete these tasks Read the section Safety Information on page 59 Power off the server using one of the methods described in the section Powering Off the System on page 63 Disconnect Power Cords From the Server on page 65 Remove the Server From the Rack on page 67 Perform Electrostatic Discharge Antistatic Prevention Measures on page 69 Remove the Top Cover on page 69 Remove a Fan Tray on page 83 Remove the Fan Tray Carriage on page 129 Unplug the front control panel cable from J9901 on the motherboard Unplug the front control panel cable from the front I O board Remove the two No 2 Phillips screws 144 SPARC Enterprise T5440 Server Service Manual July 2009 FIGURE Removing the Front Control Panel 4 Lift the front control panel up and out of the system 5 Place the front control panel on an antistatic mat V Install the Front Control Panel 1 Lower the front control panel into the system Servicing Field Replaceable Units 145 FIGURE Installing the Front Control Panel 2 3 4 Install the two No 2 Phillips screws Plug the front control panel connector into the front I O board Plug the front control panel connector into J9901 on the motherboard Next Steps Install the Fan Tray Carriage on page 131 Install a Fan Tray on page 84 Install the Top Cover on page 150 Install the Server Into the Rack
129. nd Setup Guide on the network management port Switch from the system console to the Switch From the System Console to the service processor Service Processor ILOM or ALOM CMT Compatibility Shell on page 23 Switch from the service processor to the Switch From ILOM to the System Console system console on page 23 Switch From the ALOM CMT Compatibility Shell to the System Console on page 24 Related Information a Diagnostic Flowchart on page 11 SPARC Enterprise T5440 Server Service Manual July 2009 m Switch From the System Console to the Service Processor ILOM or ALOM CMT Compatibility Shell on page 23 m Switch From ILOM to the System Console on page 23 m Switch From the ALOM CMT Compatibility Shell to the System Console on page 24 m SPARC Enterprise T5440 Server Installation and Setup Guide m SPARC Enterprise T5440 Server Administration Guide V Switch From the System Console to the Service Processor ILOM or ALOM CMT Compatibility Shell To switch from the system console to the service processor prompt type Hash Period gt Vv Switch From ILOM to the System Console From the ILOM gt prompt type start SP console gt start SP console Vv Switch From the ALOM CMT Compatibility Shell to the System Console From the ALOM CMT sc gt prompt type console sc gt console Managing Faults 23 Displaying FRU Informa
130. nformation m Identifying Server Components on page 1 m Managing Faults on page 9 m Powering Off the System on page 63 m Hot Pluggable and Hot Swappable Devices on page 72 m Fan Tray Device Identifiers on page 84 m Fan Tray Fault LED on page 84 m Server Components on page 173 Remove a Fan Tray Hot Swap Before you begin complete these tasks m Read the section Safety Information on page 59 m Perform the task Extend the Server to the Maintenance Position on page 66 m Perform the task Perform Electrostatic Discharge Antistatic Prevention Measures on page 69 Do the following 1 Identify the fan tray to be removed See Fan Tray Device Identifiers on page 84 and Fan Tray Fault LED on page 84 2 Press the fan tray latches toward the center of the fan tray and pull the fan tray up and out of the system Servicing Customer Replaceable Units 81 FIGURE Removing a Fan Tray V Install a Fan Tray Hot Swap 1 Slide the fan tray into its bay until it locks into place Ensure that the fan tray is oriented correctly Airflow in the system is from front to back 2 Verify proper fan tray operation See Fan Tray Fault LED on page 84 Next Steps If you are replacing a faulty fan tray due to an overtemperature condition monitor the system to ensure proper cooling m Slide the Server Into the Rack on page 151 If you perform
131. ng of this document to you does not give you any rights or licenses express or implied with respect to the product or technology to which it pertains and this document does not contain or represent any commitment of any kind on the part of Fujitsu Limited or Sun Microsystems Inc or any affiliate of either of them This document and the product and technology described in this document may incorporate third party intellectual property copyrighted by and or licensed from suppliers to Fujitsu Limited and or Sun Microsystems Inc including software and font technology Per the terms of the GPL or LGPL a copy of the source code governed by the GPL or LGPL as applicable is available upon request by the End User Please contact Fujitsu Limited or Sun Microsystems Inc This distribution may include materials developed by third parties Parts of the produet may be derived from Berkeley BSD systems licensed from the University of California UNIX is a registered trademark in the U S and in other countries exclusively licensed through X Open Company Ltd Sun Sun Microsystems Ty the Sun logo Java Netra Solaris Sun StorageTek docs sun com M OpenBoot SunVTS Sun Fire SunSolve CoolThreads and J2EE are trademarks or registered trademarks of Sun Microsystems Inc or its subsidiaries in the U S and thi tri z y other countries Fujitsu and the Fujitsu logo are registered trademarks of Fujitsu Limit
132. ns independently of the server using the server s standby power Therefore ILOM firmware and software continue to function when the server OS goes offline or when the server is powered off Note Refer to the Integrated Lights Out Manager 3 0 Concepts Guide for comprehensive ILOM information Faults detected by ILOM POST the Solaris Predictive Self Healing PSH technology and the External I O Expansion Unit if attached are forwarded to ILOM for fault handling FIGURE ILOM Fault Management on page 16 In the event of a system fault ILOM ensures that the Service Required LED is lit FRUID PROMs are updated the fault is logged and alerts are displayed Faulty FRUs are identified in fault messages using the FRU name Managing Faults 15 FIGURE ILOM Fault Management FRU fault LEDs Environmentals Ty ILOM System fault LED al gt fault manager gt User alerts Solaris PSH showfaults The service processor can detect when a fault is no longer present and clears the fault in several ways m Fault recovery The system automatically detects that the fault condition is no longer present The service processor extinguishes the Service Required LED and updates the FRU s PROM indicating that the fault is no longer present m Fault repair The fault has been repaired by human intervention In most cases the service processor detects the repair and extingui
133. nt Fault Fault LEDs Lit Additional Information CMP module Service Required LED front and rear or memory panel module e CMP Module Fault LED or Memory Module Fault LED FB DIMM e Service Required LED front and rear panel e CMP Module Fault LED or Memory Module Fault LED e FB DIMM Fault LED CMP and memory modules when FB DIMM Locate button is pressed Other e Service Required LED front and rear components panel A lit CMP module or memory module fault LED might indicate a problem with an FB DIMM installed on the CMP module or a problem with the CMP module itself See these sections e Front Panel LEDs on page 4 e Rear Panel LEDs on page 7 e Servicing CMP Memory Modules on page 98 e Servicing FB DIMMs on page 104 See these sections e Front Panel LEDs on page 4 e Rear Panel LEDs on page 7 e Servicing FB DIMMs on page 104 e FB DIMM Fault Button Locations on page 113 Not all components have an individual component Fault LED If the Service Required LED is lit use the show faulty command to obtain additional information about the component affected See these sections e Front Panel LEDs on page 4 e Rear Panel LEDs on page 7 Related Information m Diagnostic Flowchart on page 11 a Detecting Faults Using LEDs on page 30 a ILOM to ALOM CMT Command Reference on page 53 m SPARC Enterprise T5440 Server Installation and
134. nt is displayed FIGURE SunVTS Browser Environment Test Group Screen on page 40 FIGURE SunVTS Browser Environment Test Group Screen L apeuications version oc our Here User ia112686 Server bofa d SunVTS Host Machine View Test Group Tests Logs an Test Group on bofa d By Default all the tests are enabled To run a subset of tests select the tests that should not be run and click Disable button Then to execute enabled tests click on Start Tests button To restart a completed test reset the test counters by clicking the Reset Results button System Status idle Elapsed Time 000 00 00 sessin sv Edit Global Options Start Tests Stop Tests Reset Results Reprobe ay eJ I Enabie disable EJES Test Results Test t State Scheduling Policy t Stress t Progress Indicator t Test Status o Disk Enabled Time high idle 0 0 Interconnect Enabled Time high idle 0 o0 loports Enabled Time high idle ojo Memory Enabled Time high idle 00 Network Enabled Time high idle D 0 Processor Enabled Time high idle 0j o0 Enable Disable 4 Optional Select the test categories you want to run Certain test categories are enabled by default You can choose to accept these Note TABLE Useful
135. ode Integrated Lights Out Manager Information that describes ILOM 3 0 C120 E573 3 0 Concepts Guide features and functionality Integrated Lights Out Manager Information and procedures for network C120 E576 3 0 Getting Started Guide connection logging in to ILOM 3 0 for the first time and configuring a user account or a directory service Integrated Lights Out Manager Information and procedures for accessing C120 E574 3 0 Web Interface Procedures ILOM 3 0 functions using the ILOM web Guide interface Integrated Lights Out Manager Information and procedures for accessing C120 E575 3 0 CLI Procedures Guide ILOM 3 0 functions using the ILOM CLI Integrated Lights Out Manager Information and procedures for accessing C120 E579 3 0 SNMP and IPMI Procedure ILOM 3 0 functions using SNMP or IPMI Guide management hosts Integrated Lights Out Manager Enhancements that have been made to C120 E600 3 x Feature Updates and Release ILOM firmware since the ILOM 3 0 release Notes Integrated Lights Out Manager How to use the ILOM 3 0 software on the C120 E587 3 0 Supplement for SPARC server Enterprise T5440 Server External I O Expansion Unit Procedures for installing the External I O C120 E543 Installation and Service Manual Expansion Unit on the SPARC Enterprise T5120 T5140 T5220 T5240 T5440 servers External I O Expansion Unit Important and late breaking information C120 E544 Product Notes about the External I O Expansion Unit Note
136. omponent_state Disabled SYS MB PCIE1 component_state Enabled SYS MB PCIE4 component_state Enabled 24 SPARC Enterprise T5440 Server Service Manual July 2009 CODE EXAMPLE Output of the show components Command Showing Disabled Components Continued SYS MB PCIE2 component_state Enabled SYS MB PCIE5 component_state Enabled SYS MB NETO component_state Enabled SYS MB NET1 component_state Enabled SYS MB NET2 component_state Enabled SYS MB NET3 component_state Enabled SYS MB PCIE component_state Enabled Vv Display Individual Component Information With the ILOM show Command Use the show command to display information about individual components in the server At the gt prompt enter the show command In CODE EXAMPLE show Command Output on page 25 the show command is used to get information about a memory module FB DIMM CODE EXAMPLE show Command Output gt show SYS MB CPU0 CMP0 BR1 CH0 DO SYS MB CPU0 CMP0 BR1 CH0 DO Targets RO R1 SEEPROM SERVICE PRSNT T_AMB Properties type DIMM component_state Enabled fru_name 1024MB DDR2 SDRAM FB DIMM 333 PC2 5300 fru_description FBDIMM 1024 Mbyte fru_manufacturer Micron Technology fru_version FFFFFF fru_part_number 18HF12872FD667D6D4 fru_serial_number d81813ce fault_state OK clear_fault_action none Managing Faults 25 CODE EXAMPLE show Command Output Continued
137. on page 135 Servicing the Flex Cable Assembly on page 140 Servicing the Front Control Panel on page 144 Servicing the Front I O Board on page 146 Field Replaceable Units on page 176 Servicing the Front Bezel You must remove the front bezel in order to service the DVD ROM drive Related Information m Servicing the DVD ROM Drive on page 118 115 V Remove the Front Bezel Before you begin complete these tasks m Read the section Safety Information on page 59 a If you are performing additional service procedures power off the server using one of the methods described in the section Powering Off the System on page 63 m Extend the Server to the Maintenance Position on page 66 m Perform Electrostatic Discharge Antistatic Prevention Measures on page 69 Do the following 1 Grasp the front bezel on the left and right sides 2 Pull the bezel off of the front of the chassis The bezel is secured with three snap in posts 116 SPARC Enterprise T5440 Server Service Manual July 2009 FIGURE Removing the Front Bezel Note Avoid bending the bezel by gradually pulling it from the middle and both ends simultaneously V Install the Front Bezel 1 Align the bezel with the chassis front panel 2 Press the bezel onto the front panel The bezel is oriented with four guide pins and is secured with three snap in posts Next Steps m Slide th
138. ons to the equipment Using this product after modifying or reproducing by overhaul may cause unexpected injury or damage to the property of the user or bystanders Preface xxi Alert Label The following is a label attached to this product m Never peel off the label m The following label provides information to the users of this product SPARC Enterprise T5440 General Service Information NOTE Procedures 1 41 can be performed by custome xxii SPARC Enterprise T5440 Server Service Manual July 2009 Fujitsu Welcomes Your Comments If you have any comments or requests regarding this document or if you find any unclear statements in the document please state your points specifically on the form at the following URL For Users in U S A Canada and Mexico https download computers us fujitsu com For Users in Other Countries http www fujitsu com global contact computing sparce_index ht ml Preface xxiii xxiv SPARC Enterprise T5440 Server Service Manual July 2009 Identifying Server Components This section provides an overview of the server including major boards and components as well as front and rear panel features Description Links Overview of the infrastructure boards and Infrastructure Boards and Cables on cables in the server page 1 Overview of front panel features Front Pane
139. ou d interruptions g activites ou de tout dommage indirect sp cial secondaire ou cons cutif m me si ces entit s ont t pr alablement inform es d une telle ventualit LA DOCUMENTATION EST FOURNIE EN L ETAT ET TOUTES AUTRES CONDITIONS DECLARATIONS ET GARANTIES EXPRESSES OU TACITES SONT FORMELLEMENT EXCLUES DANS LA MESURE AUTORISEE PAR LA LOI APPLICABLE Y COMPRIS NOTAMMENT TOUTE GARANTIE IMPLICITE RELATIVE A LA QUALITE MARCHANDE A L APTITUDE A UNE UTILISATION PARTICULIERE OU A L ABSENCE DE CONTREFACON Contents Preface xiii Identifying Server Components 1 Infrastructure Boards and Cables 1 Front Panel Diagram 3 Front Panel LEDs 4 Rear Panel Diagram 5 Rear Panel LEDs 7 Ethernet Port LEDs 8 Managing Faults 9 Understanding Fault Handling Options 9 Server Diagnostics Overview 9 Diagnostic Flowchart 11 Options for Accessing the Service Processor 14 ILOM Overview 15 ALOM CMT Compatibility Shell Overview 17 Solaris Predictive Self Healing Overview 17 SunVTS Overview 18 POST Fault Management Overview 19 POST Fault Management Flowchart 20 Memory Fault Handling Overview 21 Connecting to the Service Processor 22 v Switch From the System Console to the Service Processor ILOM or ALOM CMT Compatibility Shell 23 v Switch From ILOM to the System Console 23 v Switch From the ALOM CMT Compatibility Shell to the System Console 24 Displaying FRU Information with ILOM 24 v Display System Components With th
140. page 113 These LEDs provide a quick visual check of the state of the system 30 SPARC Enterprise T5440 Server Service Manual July 2009 TABLE Component Fault TABLE ASR Commands on page 51 describes which fault LEDs are lit under given error conditions Use the ILOM show faulty command to obtain more information about the nature of a given fault See Detect Faults Using the ILOM show faulty Command on page 33 System Faults and Fault LED States Fault LEDs Lit Additional Information Power supply Fan tray Hard drive e Service Required LED front and rear panel e Front panel Power Supply Fault LED Individual power supply Fault LED e Service Required LED front and rear panel e Front panel Fan Fault LED e Individual fan tray Fault LED e Overtemp LED if overtemp condition exists e Service Required LED front and rear panel e Individual hard drive Fault LED Front Panel LEDs on page 4 Rear Panel LEDs on page 7 Power Supply LED on page 91 Servicing Power Supplies on page 85 Front Panel LEDs on page 4 Rear Panel LEDs on page 7 Fan Tray Fault LED on page 84 Servicing Fan Trays on page 81 See these sections Front Panel LEDs on page 4 Rear Panel LEDs on page 7 Hard Drive LEDs on page 80 Servicing Hard Drives on page 72 Managing Faults 31 TABLE System Faults and Fault LED States Continued Compone
141. panel of the server page 153 Power on the server after performing a Power On the Server on page 153 service procedure Related Information m Preparing to Service the System on page 59 m Servicing Customer Replaceable Units on page 71 m Servicing Field Replaceable Units on page 115 149 V Install the Top Cover If you removed the top cover perform the steps in this procedure Note If removing the top cover caused an emergency shutdown you must install the top cover and use the poweron command to restart the system See Power On the Server on page 153 1 Place the top cover on the chassis Set the cover down so that it hangs over the rear of the server by about an inch 25 4 mm 2 Slide the top cover forward until it seats 3 Secure the top cover by tightening the two captive screws along the rear edge AN AN V Install the Server Into the Rack The following procedure explains how to insert the server into the rack Caution The weight of the server on extended slide rails can be enough to overturn an equipment rack Before you begin deploy the antitilt feature on your cabinet Caution The server weighs approximately 88 lb 40 kg Two people are required to lift and mount the server into a rack enclosure when using the procedures in this chapter 1 Slide the inner slide assemblies out from the outer rails about 2 inches 5 cm from the front face of t
142. ported FB DIMM Configurations on page 110 The server uses advanced ECC technology that corrects up to 4 bits in error on nibble boundaries as long as the bits are all in the same DRAM On 4 GB FB DIMMs if a DRAM fails the DIMM continues to function The following server features independently manage memory faults POST Based on ILOM configuration variables POST runs when the server is powered on For correctable memory errors CEs POST forwards the error to the Solaris Predictive Self Healing PSH daemon for error handling If an uncorrectable memory fault is detected POST displays the fault with the device name of the faulty FB DIMMs and logs the fault POST then disables the faulty FB DIMMs Depending on the memory configuration and the location of the faulty FB DIMM POST disables half of physical memory in the system or half the physical memory and half the processor threads When this offlining process occurs in normal operation you must replace the faulty FB DIMMs based on the fault message and enable the disabled FB DIMMs with the ILOM command set device component_state enabled where device is the name of the FB DIMM being enabled for example set SYS MB CPU0 CMP0 BRO CHO DO component_state enabled m Solaris Predictive Self Healing PSH technology A feature of the Solaris OS PSH uses the Fault Manager daemon fmd to watch for various kinds of faults When a fault occurs the fault is assigned a unique fau
143. r There are three methods of interacting with the service processor m Integrated Lights Out Manager ILOM shell default Available via the System Management Port and the Network Management Port m ILOM browser interface BI Documented in the Integrated Lights Out Manager 3 0 Web Interface Procedures Guide a ALOM CMT compatibility shell Legacy shell emulation of ALOM CMT 14 SPARC Enterprise T5440 Server Service Manual July 2009 The code examples in this document depict use of the ILOM shell Note Multiple service processor accounts can be active concurrently A user can be logged in under one account using the ILOM shell and another account using the ALOM CMT shell Related Information m Diagnostic Flowchart on page 11 m SPARC Enterprise T5440 Server Installation and Setup Guide m SPARC Enterprise T5440 Server Administration Guide m Integrated Lights Out Manager 3 0 Supplement for SPARC Enterprise T5440 Server ILOM Overview The Integrated Lights Out Manager ILOM firmware runs on the service processor in the server enabling you to remotely manage and administer your server ILOM enables you to remotely run diagnostics such as power on self test POST that would otherwise require physical proximity to the server s serial port You can also configure ILOM to send email alerts of hardware failures hardware warnings and other events related to the server or to ILOM The service processor ru
144. r Service Manual July 2009 TABLE ILOM Parameters Used for POST Configuration Continued Parameter Values Description diag_trigger none Does not run POST on reset user_reset Runs POST upon user initiated resets power_on_reset Only runs POST for the first power on This option is the default error_reset Runs POST if fatal errors are detected all_resets Runs POST after any reset diag_verbosity none No POST output is displayed min POST output displays functional tests with a banner and pinwheel normal POST output displays all test and informational messages max POST displays all test informational and some debugging messages Related Information Diagnostic Flowchart on page 11 Change POST Parameters on page 28 Run POST in Maximum Mode on page 28 Detecting Faults Using POST on page 42 Clear Faults Detected During POST on page 48 SPARC Enterprise T5440 Server Installation and Setup Guide SPARC Enterprise T5440 Server Administration Guide V Change POST Parameters 1 Access the ILOM prompt See Connecting to the Service Processor on page 22 Managing Faults 27 2 Use the ILOM commands to change the POST parameters Refer to TABLE System Faults and Fault LED States on page 31 for a list of LOM POST parameters and their values The set SYS keyswitch_state command sets the virtual keyswitch parameter For example gt set SYS keyswitch_state Diag Se
145. rasp the power supply handle and press the release latch 86 SPARC Enterprise T5440 Server Service Manual July 2009 FIGURE Removing a Power Supply 5 Pull the power supply out of the chassis V Install a Power Supply Hot Swap 1 Align the replacement power supply with the empty power supply bay 2 Slide the power supply into the bay until it is fully seated Servicing Customer Replaceable Units 87 FIGURE Installing a Power Supply 3 Reconnect the power cord to the power supply Verify that the power supply LED is green or blinking green 4 Verify that the system Power Supply Fault LED and the front and rear Service Required LEDs are not lit Note See Front Panel LEDs on page 4 and Rear Panel LEDs on page 7 for more information about identifying and interpreting system LEDs 5 At the ILOM gt prompt use the show faulty command to verify the status of the power supplies 88 SPARC Enterprise T5440 Server Service Manual July 2009 A V Remove a Power Supply Caution Hazardous voltages are present To reduce the risk of electric shock and danger to personal health follow the instructions If you are removing the power supplies as a prerequisite for another service procedure follow these steps Before you begin complete these tasks m Read the section Safety Information on page 59 m Power off the server using one of the methods described in the section
146. riage on page 129 Do the following 1 Remove the flex cable retainer Loosen the captive No 2 Phillips screw and lift the retainer up and out of the chassis Unplug the cable from the hard drive backplane Loosen the three captive No 2 Phillips screws 132 SPARC Enterprise T5440 Server Service Manual July 2009 FIGURE Removing the Hard Drive Backplane x ee 4 Lift the backplane up and out of the system V Install the Hard Drive Backplane 1 Lower the hard drive backplane into the system Align the tab on the lower edge the backplane with the corresponding slot in the chassis floor Servicing Field Replaceable Units 133 FIGURE Installing the Hard Drive Backplane 2 3 4 ial Tighten the three captive No 2 Phillips screws Plug the cable into its connector on the backplane Install the flex cable retainer Place the retainer into position and tighten the captive No 2 Phillips screw Next Steps Install the Fan Tray Carriage on page 131 Install a Fan Tray on page 84 Install a CMP Memory Module on page 100 Install the Top Cover on page 150 Install a Hard Drive on page 78 Note You must install the hard drives in the correct slots Slide the Server Into the Rack on page 151 Power On the Server on page 153 134 SPARC Enterprise T5440 Server Service Manual July 2009 Servicing the Motherboard Note If you ar
147. rmal reset_nvram bootscript string set HOST bootmode value normal re set_nvram bootscript string stop SYS start SYS powercycle The f option forces an immediate poweroff Otherwise the command attempts a graceful shutdown stop SYS poweroff y e y enables you to skip the confirmation question e f forces an immediate shutdown start SYSs poweron c e c executes a console command after completion of the poweron command Displays the contents of the system s console buffer Enables control of the firmware during system initialization with the following options e normal is the default boot mode e reset_nvram resets OpenBoot PROM parameters to their default values e bootscript string enables the passing of a string to the boot command Performs a powerof followed by poweron Powers off the host server Powers on the host server 54 SPARC Enterprise T5440 Server Service Manual July 2009 TABLE ILOM Command Service Related Commands Continued ALOM CMT Command Description set SYS PSx prepare_to_remove_acti on true reset SYS reset SP set SYS keyswitch_state value normal stby diag locked set SUS LOCATE value value Fast_blink Off No ILOM equivalent show faulty removefru PSO PS1 reset y c e y enables you to skip the confirmation question e c executes a console command after completion of
148. rver on page 153 Motherboard Fastener Locations FIGURE Motherboard Fastener Locations on page 140 shows the location of the captive screws that secure the motherboard to the chassis floor Servicing Field Replaceable Units 139 FIGURE Motherboard Fastener Locations Related Information m Servicing the Motherboard on page 135 Servicing the Flex Cable Assembly The flex cable assembly provides the power and data connection between the power supply backplane hard drive backplane and motherboard Related Information m Safety Information on page 59 m Servicing Power Supplies on page 85 140 SPARC Enterprise T5440 Server Service Manual July 2009 m Servicing the Power Distribution Board on page 126 m Servicing the Hard Drive Backplane on page 132 m Servicing the Motherboard on page 135 V Remove the Flex Cable Assembly Before you begin complete these tasks m Read the section Safety Information on page 59 m Power off the server using one of the methods described in the section Powering Off the System on page 63 m Extend the Server to the Maintenance Position on page 66 m Perform Electrostatic Discharge Antistatic Prevention Measures on page 69 m Remove the Top Cover on page 69 Do the following 1 Unplug the power cords 2 Remove the flex cable retainer Loosen the captive No 2 Phillips scre
149. s and slots Use the reconf p1 script to reattach each PCle slot and onboard device to its nearest available CMP module To use the reconf pl1 you must have the following m Solaris OS JumpStart server a Net install image m The reconf pl script Do the following 158 SPARC Enterprise T5440 Server Service Manual July 2009 1 Download the reconf p1 script available at https cds sun com is bin INTERSHOP enfinity WFS CDS CDS_SMI Site en_US USD ViewProductDetail Start ProductRef IORSC SP E54440SV G F CDS CDS_ SMT 2 Copy the reconf p1 script to the root directory of the miniroot of the netinstall image This is the Solaris_10 Tools Boot directory of your exported Solaris 10 8 07 Solaris 10 5 08 or Solaris 10 10 08 OS image on your JumpStart server 3 Power off the system 4 Log into the ALOM compatibility shell Type sc gt setsc sys_ioreconfigure nextboot 5 Power on the system 6 Boot from the network Type ok boot s 7 Mount the system boot disk under the mnt directory Type mount dev dsk c0t0d0s0 mnt 8 Change to the root directory of your boot disk and copy the reconf p1 script to the root of the boot disk Type 9 Do one of the following If your Jumpstart server is exporting Solaris 10 8 07 or Solaris 10 5 08 type cp reconf pl m If your Jumpstart server is exporting Solaris 10 10 08 type cp cdrom Solaris_10
150. s regarding this product and the optional products provided from Fujitsu should only be performed by a certified service engineer Users must not perform these tasks Incorrect operation of these tasks may cause malfunction Also important alert messages are shown in Important Alert Messages on page xix Notes on Safety Important Alert Messages This manual provides the following important alert signals Caution This indicates a hazardous situation could result in minor or moderate personal injury if the user does not perform the procedure correctly This signal also indicates that damage to the product or other property may occur if the user does not perform the procedure correctly Preface xix XX Task Warning Maintenance Damage Two people must dismount and carry the chassis The weight of the server on extended slide rails can be enough to overturn an equipment rack Before you begin deploy the antitilt feature on your cabinet The server weighs approximately 88 lb 40 kg Two people are required to lift and mount the server into a rack enclosure when using the procedures in this chapter Caution This indicates that hazardous voltages are present To reduce the risk of electric shock and danger to personal health follow the instructions Task Warning Maintenance Electric shock Never attempt to run the server with the covers removed Hazardous voltage presen
151. s to allow the system to run in a degraded state ILOM commands and equivalent ALOM CMT commands Understanding Fault Handling Options on page 9 Connecting to the Service Processor on page 22 Displaying FRU Information with ILOM on page 24 Controlling How POST Runs on page 26 Detecting Faults on page 30 Clearing Faults on page 47 Disabling Faulty Components on page 50 ILOM to ALOM CMT Command Reference on page 53 Understanding Fault Handling Options Server Diagnostics Overview You can use a variety of diagnostic tools commands and indicators to monitor and troubleshoot a server m LEDs Provide a quick visual notification of the status of the server and of some of the FRUs ILOM firmware This system firmware runs on the service processor In addition to providing the interface between the hardware and OS ILOM also tracks and reports the health of key server components ILOM works closely with POST and Solaris Operating System Solaris OS Predictive Self Healing technology to keep the system up and running even when there is a faulty component Power on self test POST POST performs diagnostics on system components upon system reset to ensure the integrity of those components POST is configurable and works with ILOM to take faulty components offline if needed m Solaris OS Predictive Self Healing PSH This technology continuously monitors the hea
152. shes the Service Required LED If the service processor does not perform these actions you must perform these tasks manually by setting the ILOM component_state or fault_state of the faulted component The service processor can detect the removal of a FRU in many cases even if the FRU is removed while the service processor is powered off for example if the system power cables are unplugged during service procedures This function enables ILOM to know that a fault diagnosed to a specific FRU has been repaired Note ILOM does not automatically detect hard drive replacement Many environmental faults can automatically recover A temperature that is exceeding a threshold might return to normal limits An unplugged power supply can be plugged in and so on Recovery of environmental faults is automatically detected Note No ILOM command is needed to manually repair an environmental fault The Solaris Predictive Self Healing technology does not monitor the hard drive for faults As a result the service processor does not recognize hard drive faults and will not light the fault LEDs on either the chassis or the hard drive itself Use the Solaris message files to view hard drive faults Related Information a Diagnostic Flowchart on page 11 16 SPARC Enterprise T5440 Server Service Manual July 2009 m Detecting Faults Using LEDs on page 30 m Detecting Faults Using Solaris OS Files and Commands on pag
153. t Because 3 3v standby power is always present in the system you must unplug the power cords before accessing any cold serviceable components Caution This indicates that surfaces are hot and might cause personal injury if touched Avoid contact Task Warning Maintenance Extremely hot FB DIMMs may be hot Use caution when servicing FB DIMMs SPARC Enterprise T5440 Server Service Manual July 2009 Product Handling Maintenance Warning Certain tasks in this manual should only be performed by a certified service engineer User must not perform these tasks Incorrect operation of these tasks may cause electric shock injury or fire m Installation and reinstallation of all components and initial settings m Removal of front rear or side covers Mounting de mounting of optional internal devices m Plugging or unplugging of external interface cards m Maintenance and inspections repairing and regular diagnosis and maintenance Caution The following tasks regarding this product and the optional products provided from Fujitsu should only be performed by a certified service engineer Users must not perform these tasks Incorrect operation of these tasks may cause malfunction m Unpacking optional adapters and such packages delivered to the users m Plugging or unplugging of external interface cards Remodeling Rebuilding Caution Do not make mechanical or electrical modificati
154. t keyswitch_state to Diag To change individual POST parameters you must first set the keyswitch_state parameter to normal For example gt set SYS keyswitch_state Normal Set ketswitch_state to Normal gt set HOST diag property Min YV Run POST in Maximum Mode This procedure describes how to run POST when you want maximum testing as in the case when you are troubleshooting a server or verifying a hardware upgrade or repair 1 Access the ILOM prompt See Connecting to the Service Processor on page 22 2 Set the virtual keyswitch to diag so that POST will run in service mode gt set SYS keyswitch_state Diag Set keyswitch_state to Diag 3 Reset the system so that POST runs There are several ways to initiate a reset CODE EXAMPLE Initiating POST With a Power Cycle on page 29 shows a reset using a power cycle command sequence For other methods refer to the SPARC Enterprise T5440 Server Administration Guide Note The server takes about one minute to power off Use the show HOST command to determine when the host has been powered off The console will display status Powered Off 28 SPARC Enterprise T5440 Server Service Manual July 2009 4 Switch to the system console to view the POST output gt start SP console If no faults were detected the system will boot CODE EXAMPLE POST Output Abridged on page 29 depi
155. t Ethernet ports power supplies Locator button and LED and system status LEDs FIGURE Rear Panel Features on page 6 shows rear panel features on the SPARC Enterprise T5440 server For more detailed information about ports and their uses see the SPARC Enterprise T5440 Server Installation and Setup Guide For a detailed description of PCIe slots see PCIe Device Identifiers on page 96 Identifying Server Components 5 FIGURE Rear Panel Features Figure Legend Power supplies Serial port Serial management port System status LEDs USB ports Network management port N Oo oO fF WD Gigabit Ethernet ports Related Information m Front Panel Diagram on page 3 m Rear Panel LEDs on page 7 m Ethernet Port LEDs on page 8 a Detecting Faults Using LEDs on page 30 6 SPARC Enterprise T5440 Server Service Manual July 2009 Rear Panel LEDs TABLE Rear Panel System LEDs on page 7 describes the rear panel system LEDs TABLE Rear Panel System LEDs LED Icon Description Locator LED The Locator LED enables you to find a particular system The LED is and button activated using one of the following methods white e The ALOM CMT command setlocator on e The ILOM command set SYS LOCATE value Fast_Blink e Manually press the Locator button to toggle the Locator LED on or off This LED provides the following indications e Off Normal operating state
156. t Pluggable and Hot Swappable Devices on page 72 m Front Panel LEDs on page 4 m Rear Panel LEDs on page 7 Servicing PCle Cards Up to eight low profile PCle cards may be installed in the system All slots are wired to x8 PCle lanes Slot 1 and Slot 7 support graphics cards with x16 connectors Slot 4 and Slot 5 also support 10 Gbyte Ethernet cards XAUI cards When a XAUI card is installed a PCIe card cannot be installed in the same slot Related Information a PCle Device Identifiers on page 96 92 SPARC Enterprise T5440 Server Service Manual July 2009 m PCle Slot Configuration Guidelines on page 97 m Performing Node Reconfiguration on page 155 V Remove a PCIe Card Before you begin complete these tasks m Read the section Safety Information on page 59 m Power off the server using one of the methods described in the section Powering Off the System on page 63 m Extend the Server to the Maintenance Position on page 66 m Perform Electrostatic Discharge Antistatic Prevention Measures on page 69 m Remove the Top Cover on page 69 Do the following 1 Identify the PCIe card you want to remove 2 Open the PCIe card latch FIGURE Removing a PCle Card 3 Remove the PCIe card the system 4 Place the PCIe card on an antistatic mat 5 If you are not replacing the PCIe card install a PCIe filler panel in its place 6 Close the PCIe card latch
157. t aucune licence expresses ou tacites concernant le produit ou la technologie auxquels ilse rapporte Par ailleurs il ne contient ni ne repr sente aucun engagement de quelque type que ce soit de la part de Fujitsu Limited ou de Sun Microsystems Inc ou des soci t s affili es Ce document et le pr duit et les technologies qu il d crit peuvent inclure des droits de propri t intellectuelle de parties tierces prot g s par copyright et ou c d s sous licence par des fournisseurs Fujitsu Limited et ou Sun Microsystems Inc y compris des logiciels et des technologies relatives aux polices de caract res Par limites du GPL ou du LGPL une copie du code source r gi par le GPL ou LGPL comme applicable est sur demande vers la fin utilsateur disponible veuillez contacter Fujitsu Limted ou Sun Microsystems Inc Cette distribution peut comprendre des composants d velopp s par des tierces parties Des parties de ce produit pourront tre d riv es des syst mes Berkeley BSD licenci s par l Universit de Californie UNIX est une marque d pos e aux Etats Unis et dans d autres pays et licenci e exclusivement par X Open Company Ltd Sun Su pee baat le Jobo Sun Java Netra Solaris Sun StorageTek docs sun com OpenBoot SunVTS Sun Fire SunSolve CoolThreads et J2EE sont des marques de fabrique ou des marques d pos es de Sun Microsystems Inc ou ses filiales aux Etats Unis et dans d
158. the reset command resetsc y e y enables you to skip the confirmation question setkeyswitch y value normal stby diag locked e y enables you to skip the confirmation question when setting the keyswitch to stby setlocator value on off showenvironment showfaults v Indicates if it is okay to perform a hot swap of a power supply This command does not perform any action But this command provides a warning if the power supply should not be removed because the other power supply is not enabled Generates a hardware reset on the host server Reboots the service processor Sets the virtual keyswitch Turns the Locator LED on the server on or off Displays the environmental status of the host server This information includes system temperatures power supply front panel LED hard drive fan voltage and current sensor status See Display Individual Component Information With the ILOM show Command on page 25 Displays current system faults See Detecting Faults on page 30 Managing Faults 55 TABLE Service Related Commands Continued ILOM Command ALOM CMT Command Description No ILOM equivalent showfru g lines s d FRU g lines specifies the number of lines to display before pausing the output to the screen s displays static information about system FRUs defaults to all FRUs unless one is specified d displays dynamic information about
159. tion m Servicing the Service Processor on page 120 m Servicing the Battery on page 125 Remove the IDPROM Before you begin complete these tasks m Read the section Safety Information on page 59 m Power off the server using one of the methods described in the section Powering Off the System on page 63 m Extend the Server to the Maintenance Position on page 66 m Disconnect Power Cords From the Server on page 65 m Perform Electrostatic Discharge Antistatic Prevention Measures on page 69 m Remove the Top Cover on page 69 m Remove the Service Processor on page 120 1 Lift the IDPROM up off its connector on the service processor Servicing Field Replaceable Units 123 FIGURE Removing the IDPROM 2 Place the IDPROM on an antistatic mat Y Install the IDPROM Before you begin complete these tasks Read the section Safety Information on page 59 Power off the server using one of the methods described in the section Powering Off the System on page 63 Extend the Server to the Maintenance Position on page 66 Disconnect Power Cords From the Server on page 65 Perform Electrostatic Discharge Antistatic Prevention Measures on page 69 Remove the Top Cover on page 69 Remove the Service Processor on page 120 124 SPARC Enterprise T5440 Server Service Manual July 2009 Plug the IDPROM into its connector on t
160. tion with ILOM Vv Display System Components With the ILOM show components Command The show components command displays the system components asrkeys and reports their status At the gt prompt type the show components command CODE EXAMPLE Output of the show components Command With No Disabled Components on page 24 shows partial output with no disabled components CODE EXAMPLE Output of the show components Command Showing Disabled Components on page 25 shows the showcomponents command output with a component disabled CODE EXAMPLE Output of the show components Command With No Disabled Components gt show components Target Property Value Bees Se tobe sees aos Poe eee ee eto eee ee toate oe ee oe eee eee SYS MB PCIEO component_state Enabled SYS MB PCIE3 component_state Enabled SYS MB PCIE1 component_state Enabled SYS MB PCIE4 component_state Enabled SYS MB PCIE2 component_state Enabled SYS MB PCIE5 component_state Enabled SYS MB NETO component_state Enabled SYS MB NET1 component_state Enabled SYS MB NET2 component_state Enabled SYS MB NET3 component_state Enabled SYS MB PCIE component_state Enabled CODE EXAMPLE Output of the show components Command Showing Disabled Components gt show components Target Property Value pe Se eee ee See ee eee a ee ee eee ee eee SYS MB PCIEO component_state Enabled SYS MB PCIE3 c
161. to identify PSH detected faults m If no fault is reported you do not need to do anything else Do not perform the subsequent steps m Ifa fault is reported perform Step 3 and Step 4 3 Use the clear_fault_action property of the FRU to clear the fault from the service processor For example gt set SYS MB CPU0 CMP0 BRO CHO DO clear_fault_action True Are you sure you want to clear SYS MB CPU0 CMP0 BRO CH0O DO y n y Set clear_fault_action to true 4 Clear the fault from all persistent fault records In some cases even though the fault is cleared some persistent fault information remains and results in erroneous fault messages at boot time To ensure that these messages are not displayed perform the following Solaris command fmadm repair UUID Example fmadm repair 7ee0e46b ea64 6565 e684 e996963 7b86 Managing Faults 49 Vv Clear Faults Detected in the External I O Expansion Unit For service processor detected faults in the External I O Expansion Unit the fault must be manually cleared from ILOM show faulty after the problem has been repaired Note After the problem has been repaired the fault will also be cleared from the ILOM show faulty command by resetting the service processor The example below shows a problem detected in the External I O Expansion Unit gt show faulty Target Property Value ae Et te ee te Sena I an a kDa Pet tee no ee OP an Oe Oe eee SP fau
162. tware The SunVTS software features a Java based browser environment an ASCII based screen interface and a command line interface For more information about how to use the SunVTS software see the SunVTS 7 0 User s Guide The Solaris OS must be running in order to use the SunVTS software You also must ensure that the SunVTS validation test software is installed on your system This section describes the tasks necessary to use SunVTS software to exercise your server Related Information m Diagnostic Flowchart on page 11 a Verify Installation of SunVTS Software on page 38 m Start the SunVTS Browser Environment on page 39 m SunVTS Software Packages on page 41 m Useful SunVTS Tests on page 42 m SPARC Enterprise T5440 Server Administration Guide m SunVTS 7 0 User s Guide V Verify Installation of SunVTS Software To perform this procedure the Solaris OS must be running on the server and you must have access to the Solaris command line Note The SunVTS 7 0 software and future compatible versions are supported on the server 38 SPARC Enterprise T5440 Server Service Manual July 2009 The SunVTS installation process requires that you specify one of two security schemes to use when running SunVTS The security scheme you choose must be properly configured in the Solaris OS for you to run the SunVTS software For details refer to the SunVTS User s Guide 1 Check for the presence o
163. ty components detected by 48 parameters changing 27 running in maximum mode 28 troubleshooting with 14 using for fault diagnosis 13 Predictive Self Healing PSH about 17 clearing faults 49 faults detected by 12 faults displayed by ILOM 33 memory faults 21 PSH see Predictive Self Healing PSH Q quick visual notification 10 R rack extending server to maintenance position 65 removing server from 67 Ready to Remove hard drive LED 74 76 rear panel access 5 rear panel LEDs 7 removefru command 55 removing 132 battery 125 CMP memory module 99 DVD ROM drive 118 fan tray 81 83 fan tray carriage 129 FB DIMMs 105 flex cable assembly 141 front bezel 116 front control panel 144 front I O board 147 hard drive 73 77 hard drive backplane 132 IDPROM 123 motherboard 135 PCle card 93 Index 183 power distribution board 126 power supply 86 89 server from rack 67 service processor 120 reset command 55 reset system using ILOM 28 using POST commands 28 resetsc command 55 S safety information 59 safety symbols 60 sanity check for hardware components 19 SCC module and host ID 2 and MAC addresses 2 serial management port pinouts 167 serial number chassis 62 serial port DB 9 pinouts 169 service processor installing 122 removing 120 Service Required system LED 32 about 4 cleared by enablecomponent command 48 interpreting to diagnose faults 31 triggered by
164. ule is paired with a memory module CMP modules and memory modules are keyed uniquely to prevent incorrect insertion into the wrong type of slot A faulty CMP or memory module is indicated with an alluminated fault LED An alluminated module LED also might indicate a faulty FB DIMM on that module FIGURE CMP Memory Module Pairs 98 SPARC Enterprise T5440 Server Service Manual July 2009 Related Information CMP and Memory Module Device Identifiers on page 103 Supported CMP Memory Module Configurations on page 104 I O Connections to CMP Memory Modules on page 156 Reconfiguring I O Device Nodes on page 158 Servicing FB DIMMs on page 104 System Bus Topology on page 162 I O Fabric in 2P Configuration on page 164 I O Fabric in 4P Configuration on page 165 Remove a CMP Memory Module Before you begin complete these tasks Read the section Safety Information on page 59 Power off the server using one of the methods described in the section Powering Off the System on page 63 Extend the Server to the Maintenance Position on page 66 Perform Electrostatic Discharge Antistatic Prevention Measures on page 69 Remove the Top Cover on page 69 Do the followin
165. ult then the fault fault is an environmental fault Environmental faults Detecting Faults on can be caused by faulty FRUs power supply or fan page 30 or by environmental conditions such as when computer room ambient temperature is too high or the server airflow is blocked When the environmental condition is corrected the fault will automatically clear If the fault indicates that a fan or power supply is bad you can perform a hot swap of the FRU You can also use the fault LEDs on the server to identify the faulty FRU fans and power supplies If the FRU displayed by the show faulty command is SYS the fault is a configuration problem SYS indicates no faulty FRU has been diagnosed but there is a problem with the system configuration 7 Determine if the Problems detected in the External I O Expansion Detecting Faults Using fault was detected in the External I O Expansion Unit Unit include the text string Ext FRU or Ext Sensor at the beginning of the fault description ILOM show faulty Command on page 32 Clear Faults Detected in the External 1 O Expansion Unit on page 50 Managing Faults 13 TABLE Diagnostic Flowchart Actions Continued Action No Diagnostic Action Resulting Action For more information 8 Determine if the If the fault displayed included a uuid and Identifying Faults fault was detected sunw msg id property the fault was detected by the Detected by PSH on by PSH Sol
166. w and lift the retainer up and out of the chassis Servicing Field Replaceable Units 141 FIGURE Removing the Flex Cable Retainer Aa ill k CE PRS Unplug the flex cable to power supply backplane connection Unplug the flex cable to hard drive backplane connection Unplug the flex cable to DVD ROM drive connection Unplug the flex cable to motherboard connection Lift the flex cable up and out of the system V Install the Flex Cable Assembly 1 2 3 Ensure the power cables are unplugged Plug in the motherboard connector Plug in the hard drive backplane connector Plug in the DVD ROM drive connector Plug in the power supply backplane connector 142 SPARC Enterprise T5440 Server Service Manual July 2009 6 Install the flex cable retainer Place the retainer into position and tighten the captive No 2 Phillips screw FIGURE Installing the Flex Cable Retainer 7 Plug in the power cables Next Steps m Install the Top Cover on page 150 m Slide the Server Into the Rack on page 151 m Power On the Server on page 153 Servicing Field Replaceable Units 143 Servicing the Front Control Panel The front control panel contains system status LEDs and the Power button Related Information Infrastructure Boards and Cables on page 1 Front Panel Diagram on page 3 Front Panel LEDs on page 4 V Remove the Front Control Panel Before you begi
167. w faulty command provides summary information about the fault See Detect Faults Using the ILOM show faulty Command on page 33 for more information about the show faulty command 44 SPARC Enterprise T5440 Server Service Manual July 2009 Note The Service Required LED is also turned on for PSH diagnosed faults Related Information m Diagnostic Flowchart on page 11 m Solaris Predictive Self Healing Overview on page 17 m ILOM to ALOM CMT Command Reference on page 53 m SPARC Enterprise T5440 Server Administration Guide m Integrated Lights Out Manager 3 0 Supplement for SPARC Enterprise T5440 Server Vv Detect Faults Identified by the Solaris PSH Facility Using the ILOM fmdump Command The ILOM fmdump command displays the list of faults detected by the Solaris PSH facility and identifies the faulty FRU for a particular EVENT_ID UUID Note Do not use fmdump to verify that a FRU replacement has cleared a fault because the output of fmdump is the same after the FRU has been replaced Use the fmadm faulty command to verify that the fault has cleared See Clear Faults Detected by PSH on page 49 1 Check the event log using the fmdump command with v for verbose output In CODE EXAMPLE Output from the fmdump v Command on page 46 a fault is displayed indicating the following details m Date and time of the fault Jul 31 12 47 42 2007 m Universal Unique Identifier UUID The UUID is unique
168. witch position 108 also see setkeyswitch command O Overtemp system LED 5 31 overtemperature condition 31 P PCIe card adding 94 configuration guidelines 97 182 SPARC Enterprise T5440 Server Service Manual July 2009 device identifiers 96 installing 94 removing 93 PCle fabric reconfiguration 158 pinouts Gigabit Ethernet ports 170 network management port 168 serial management port 167 serial port DB 9 169 USB ports 169 power cords plugging into server 153 unplugging before servicing the system 61 power distribution board about 2 installing 128 removing 126 power off 64 Power OK system LED 12 power supply about 85 AC Present LED 12 92 DC OK LED 91 device identifiers 91 Fault LED 31 86 92 hot swapping 87 90 installing 87 90 removing 86 89 Power Supply Fault system LED about 5 92 interpreting to diagnose faults 31 using to verify successful power supply replacement 88 powercycle command 28 54 powering off server emergency shutdown 65 from service processor prompt 64 graceful shutdown 64 service processor command 64 powering on at service processor prompt 153 following emergency shutdown triggered by top panel removal 150 153 using Power button 153 poweron command 54 power on self test POST 19 about 19 components disabled by 51 configuration flowchart 20 controlling output 26 error messages 42 fault clearing 48 faults detected by 12 33 faul
Download Pdf Manuals
Related Search
Related Contents
CRF 450R / 2006 - Motorock SC443 IS 7032-1 to 8 (1986): Physical methods of test for uncut Indian jute Fre - unesdoc Contenido: - Iniciar sesión Audionet SAM G2 Manual EDK II Flash Definition (FDF) File Format Specification Zakres programowania rejestratora KD7 各種料金表 - 横浜ケーブルビジョン Manejo del Teletexto - Instructions Manuals Copyright © All rights reserved.