1. Non esporre l unit a gas infiammabili potrebbero essere fonti di pericolo Never use the unit to support other equipment n case of breakdown or failure turn unit off do not Neverleave tools spare parts etc inside the unit ry to repair it on your own call operator Make sure that all inspection panels are closed properly If you are going to leave the generator off for a long Do no expose the unit to inflammable gases ime first make sure that in no way this could cause harm to anyone in any way Tenere presente che modifiche elettriche meccaniche e manomissioni in genere fanno decadere la garanzia Please do not forget that warranty cannot be applied in case of electric mechanical and other general modifications Componenti principali Main components Pag 03 Di serie Standard Ventilatore centrifugo a doppia Double inlet centrifugal fan 1 aspirazione pale curve avanti forward curved fins Motore elettrico 230V 1Ph 50Hz dirett Electric motor 230V 1Ph 50Hz 2 s accoppiato al ventilatore directly coupled to the fan 3 Griglia di protezione antinfortunistica Fan protection grill Cassa portante in lamiera zincata e Main CL m de of galvanized 4 pre painted steel prevemiciata colore bianco RAL 9002 white RAL 9002 colour 5 Staffa di fissaggio orientabile Adjustable installation supporting kit Imballo Packing Le unit vengono spedite con imballo sta
2. ATTENTION When the unit is running do not place any object or cloths to dry on the air outflow grill they would Obstruct the flow and damage the unit Norme per l utente Manutenzione Pulizia Information for the user Maintenance Cleaning Pag 09 Queste unit sono costruite con tecnologie moderne che ne assicurano l efficienza ed il funzionamento nel tempo essenziale stabilire e seguire un regolare programma di ispezioni e manutenzione Il programma di manutenzione seguente stabilito considerando condizioni ottimali sullo stato di inquinamento dell aria del luogo di installazione Quindi le indicazioni dei tempi di intervento per una corretta manutenzione sono puramente indicativi e possono variare in relazione alle effettive condizioni di lavoro Le condizioni atmosferiche pi aggressive si hanno quando nell aria esiste una quantit anomala di fumi industriali sali fumi chimici e polveri industriali These units are constructed with state of the art technology that ensures long terms efficiency and operation t is essential to provide a very specific inspection and maintenance program in functions of those fluids characteristics The following maintenance program is established by taking into consideration the unit optimal conditions relative to the air quality and the installation site characteristics The response time for a correct servicing very much depends on the above conditions The most aggressiv
3. NOTE To control more than 1 unit or 1 unit with 2 motors it is recommended to keep the electrical power supply of the different motors SEPARATE AND INDEPENDENT FROM EACH OTHER To do so it is recommended 1o install 3 relays one each speed by independent contacts one contact each motor to be controlled or install the INTERFACE CHART accessory this way should any inconvenience happen to any of the fan motors it would not involve nor interfere with the others For installation of control panel choose an area where the max and min room temperature limit is respected 0 45 C 85 U R Do not install the control panel on metallic walls if the metallic wall is not permanently earthed Staffa orientabile Adjustable bracket Pag 07 Possibilit di utilizzo con qualsiasi angolazione a 360 per particolari applicazioni di tipo industriale tecnologico Any angulation possibility at 360 for special industrial technological applications Prima accensione First start La staffa di sostegno orientabile fornita standard assieme all unit consente una variet di inclinazioni diverse a seconda delle caratteristiche del portone sul quale viene posizionata The adjustable installation supporting kit standard supplied together with the unit allows a variety of different inclinations according to the gate characteristics A A A ESO PRIMA DI AVVIARE L UNIT VERIFICARE
4. SEGUENTI PUNTI Ancoraggio dell unit al soffitto o al muro pavimento tetto ecc Connessione del cavo di terra e serraggio di tutti i morsetti elettrici Eventuale collegamento dei canali Chiusura dei pannelli ispezionabili Tensione di alimentazione disponibile Assicurarsi che siano state rispettate le disposizioni e le norme vigenti sulla installazione di queste unit PER EFFETTUARE LA PRIMA ACCENSIONE OPERARE NEL SEGUENTE MODO Assicurarsi che l interruttore generale magnetotermico sia inserito Dare tensione all unit gt Estate regolare il termostato ambiente se presente ad una temperatura inferiore di alcuni gradi a quella esistente gt Inverno regolare il termostato ambiente se presente ad una temperatura superiore di alcuni gradi a quella esistente Si raccomanda di far funzionare l unit alla velocit massima per alcune ore appena montata e dopo lunghi periodi di inattivit AD UNIT IN FUNZIONE VERIFICARE Assorbimento elettrico e portata aria INFORMAZIONI ALL UTENTE Si raccomanda di informare l utente su tutte le operazioni necessarie al corretto funzionamento dell unit con particolare riguardo all importanza sui controlli periodici che dovranno essere effettuati da personale specializzato ATTENZIONE Le operazioni di prima accensione devono essere effettuate da personale qualificato WARNING The unit initial start up operations and the relative tests must be performed by skil
5. closed inside a space accessible only with the use of proper tools Fans can reach a speed of 1000 rpm Do not insert any object nor hands in the electric fan Installare in prossimit dell unit in posizione facilmente accessibile un interruttore di sicurezza che tolga la corrente alla macchina Prima di qualsiasi operazione di pulizia o manutenzione togliere l alimentazione elettrica dall unit Prima di accedere all unit assicurarsi che tutte le utenze elettriche siano state interrotte In particolare prima di aprire i pannelli d ispezione accertarsi che il ventilatore sia spento e che non possa essere riacceso all insaputa di chi sta intervenendo sulla unit stessa J VERIFICARE IL COLLEGAMENTO DELLA MESSA A TERRA We recommend to install a safety switch which can be easily reached to cut off the current near the unit Before any cleaning and servicing operation cut off the power line to the unit Ss Before opening the unit make sure that all electrical parts have been switched off In particular make sure that the fan is off and cannot be inadvertently started prior to opening inspection panels CHECK THE EARTHING Questa unit dovr essere destinata solo all uso di ventilazione Ogni altro uso da considerarsi improprio e quindi pericoloso Se l unit viene installata in ambienti con persone inabili e o bambini dovr essere posizionata in modo che non sia di facile accesso Assicurarsi
6. i CLIMA iem lw le Ir treatment ari all ell o d d trattamento BPS BA 101 MADE INHTALY Ce oc MI03 51022040 R00 BARRIERE ARIA uem Mii cit elettriche AIR FIERO oniy air az electrical Osservazioni Remarks Manuale Installazione Uso e Manutenzione Installation Use and Service Manual ARRIERE A SOLA ARIA RRIERS WITH AIR ONLY BIM 0301 60021192 R02 Ai fini di un utilizzo corretto e sicuro dell unit l installatore l utente ed il manutentore per le rispettive competenze sono tenuti ad osservare scrupolosamente quanto indicato nel presente manuale Conservare questo libretto in luogo asciutto per evitare il deterioramento per almeno 10 anni per eventuali riferimenti futuri leggere attentamente e completamente tutte le informazioni contenute in questo libretto forniscono importanti indicazioni riguardanti la sicurezza d installazione uso e manutenzione Prestare particolare attenzione alle norme d uso accompagnate dalle scritte PERICOLO o ATTENZIONE in quanto se non osservate possono causare danno all unit e o a persone e cose Per anomalie non contemplate da questo libretto interpellare tempestivamente il Servizio Assistenza di zona Assicurarsi che questo libretto accompagni sempre l unit Il libretto costituisce parte integrante ed essenziale del prodotto e dovr essere consegnato all utilizzatore
7. di personale tecnico specializzato ed in particolare della ditta installatrice che avendo completato i lavori dell impianto in grado di verificarne la sicurezza e la funzionalit nel suo complesso Prima della prima accensione dell unit verificare che la ditta installatrice abbia effettuato tutte le operazioni di propria competenza Non lasciare l unit inutilmente alimentata quando la stessa non utilizzata GUASTO O CATTIVO FUNZIONAMENTO In caso di guasto e o di cattivo funzionamento dell unit Disattivare l unit scollegare l alimentazione elettrica Astenersi da qualsiasi tentativo di riparazione o di intervento diretto Rivolgersi esclusivamente a personale professionalmente qualificato L eventuale riparazione dell unit dovr essere effettuata solamente da un Centro di Assistenza autorizzato dalla casa costruttrice utilizzando solamente ricambi originali Il mancato rispetto di quanto sopra pu compromettere la sicurezza dell unit ATTENZIONE Per garantire l efficienza dell unit e per il suo corretto funzionamento indispensabile fare effettuare da personale professionalmente qualificato la manutenzione annuale attenendosi alle indicazioni del costruttore STARTING AND STOPPING THE UNIT WARNING It should be recalled that the first start up of the unit and the relative tests must be performed by skilled technical personnel Non compliance with this procedure will invalidate the warranty condi
8. che la porta di accesso ai comandi interni sia sempre chiusa Un errata installazione pu causare danni a persone animali e cose nei confronti dei quali il costruttore non pu essere considerato responsabile Il costruttore non pu essere considerato responsabile per eventuali danni derivanti da usi impropri erronei o irragionevoli This unit is designed to be used for ventilating only Any different use is not allowed as it may be dangerous Should the unit work in a house where disabled people and or children live it must be placed safely away from their reach Always make sure that the access door to the inside control board stay locked An incorrect installation can cause damages to people animals and property In case of erroneous installation the manufacturer cannot be held responsible for such damages The manufacturer cannot be held responsible for such damages by improrer uses errate uses etc Non usare l unit come sostegno per altro macchinario n caso di guasto o cattivo funzionamento dell unit Non lasciare all interno dell unit utensili stracci parti di disattivarla astenendosi da qualsiasi tentativo di ricambio ecc riparazione e chiedere l intervento dell installatore Non lasciare i pannelli di ispezione parzialmente chiusi Dal momento che si decide di non utilizzare pi l unit accertarsi che tutte le viti siano perfettamente serrate si dovranno rendere innocue quelle parti che
9. confermati da entrambe le parti 5 Non sono coperte dalla garanzia tutte le parti che dovessero risultare difettose a causa di negligenza incuria trascuratezza nell uso errata installazione errata manutenzione manutenzione eseguita da personale non qualificato e o non autorizzato danni derivanti da incidenti danni derivanti da trasporto guasti conseguenti ad azioni volontarie o accidentali ovvero circostanze che comunque non possono farsi risalire a difetti di fabbricazione 6 Ai sensi dell art 1495 c c l Utente decade dal diritto di garanzia se non denunzia i vizi al costruttore per iscritto entro 8 giorni dalla scoperta salvo diversi accordi scritti e confermati da entrambe le parti 7 Non sono coperte dalla garanzia le normali operazioni di manutenzione periodica es pulizia filtri aria quando previsti e le conseguenze dovute alla normale usura delle unit es filtri aria quando previsti 8 Eventuali malfunzionamenti guasti componenti difettosi danni diretti ed indiretti provocati a persone animali e cose non conferiscono al committente alcun diritto di differire eventuali pagamenti in corso ritardi dei pagamenti da parte del compratore sospendono e annullano ogni garanzia La garanzia esclude qualsiasi indennizzo per il periodo di inefficienza delle unit 10 Le nostre unit sono garantite per un periodo di Gruppo ventilante e Parti elettriche anno Struttura portante Componenti in lamiera e Mobile di cope
10. is indicated by the design or other documents Always keep packing parts away from children reach as they may be harmful Before the unit installation please wear suitable protective clothes Use suitable equipments and tools to avoid any installation accident Before the unit installation we recommand to muont on the unit the eventual separating optionals by following the assembly instructions contained in each single kit Decide the installation position Locate the unit on a solid structure which does not cause vibrations and is able to support the machine KE Segnare attraverso le 4 aperture predisposte sulla staffa di fissaggio la posizione dei tasselli di sostegno ad espansione Eseguire la foratura per i 4 tasselli Installare l unit con n 4 viti ad espansione 10 MA o barra filettata 10 mm Installare l unit in una posizione tale da non compromettere l aspirazione e l emissione dell aria Mark through the 4 bracket fixing holes the position of the holding expansion dowels Make the 4 holes for the dowels Install the unit with no 4 expansion screws 10 MA or threaded rod b 10 mm The unit must be installed so that the air intake and supply are not jeopardized Il sollevamento deve essere preferibilmente fatto con l ausilio di mezzi meccanici a causa del peso dell unit The lifting should be done with mechanical devices because of the weight of the unit Installazione Spazi tecn
11. jurisdiction of the judicial authorities of Treviso Italy Tutti gli schemi elettrici sono soggetti ad aggiornamento opportuno fare riferimento allo schema elettrico allegato all unit dati tecnici contenuti nel presente Bollettino di Installazione Uso e Manutenzione non sono impegnativi per l azienda ed il costruttore si riserva il diritto di apportare qualsiasi modifica a dati tecnici prestazioni dimensioni ecc senza obbligo di preavviso La riproduzione totale o parziale del presente Bollettino di Installazione Uso e Manutenzione proibita All wiring diagrams are subjected to updatings we suggest to make reference to the wiring diagram included in every unit All technical data in this Installation Use and Service Bulletin are not binding for the manufacturer and the manufacturer reserves the right to do any change technical data performances dimensions etc without preadvice Total or partial reproduction of this Installation Use and Service Bulletin is forbidden treatment aria c O O le jud e Qo z 9 P ur ul P Par Ba CLIMA BPS S r l Zona Industriale Biban 56 31080 Carbonera TV Italy Tel 39 0422 445863 r a Fax 39 0422 398646 www bpstecnologie com e mail info bpstecnologie com
12. safety and savings It is recommended to carry out the following operations every month during operation Clean the external parts of the unit simply by using a damp cloth AIR FILTER If any Cleaning every 15 days The cells may be cleaned by a simple flapping or by washing them into water detergent or by using compressed air blast IMPORTANT when cleaning the cells make sure that the water air blast is crossing the media in the opposite direction of the one of normal unit operation The blasting over the media must not be too hard or near so to avoid possible damages of the filtering mass If the cells are washed with water detergent dry them up in open air before re installation in order not to affect the system efficiency FAN MOTOR GROUP As well the motor as the fans rotate on self lubricating bearings which do not need any lubrication Check the wheel is clean If this is not the case clean it using compressed air in such a way not to damage the wheel YEARLY CHECKS In order to grant the unit always the best performance and upkeep carry out timely maintenance operations at least once a year Remember that maintenance operations are to be carried out by qualified personnel only Electrical equipment check Check all the electrical apparatus and in particular the tightness of the electrical connections Check the tightness of all the nuts bolts and flanges which may have been loosened by vibrations Check
13. the barrier at every opening and or only the barrier according to the gate opening degree Il ventilatore a 3 velocit consente di variare la potenza di emissione dell aria in funzione dell altezza del portone The 3 speeds fan allows to change the air emission power according to the gate height Modello Model 10 20 30 40 Altezza di Min H1 m 25 3 0 3 2 3 7 installazione Installation Med H2 m 30 35 37 43 height Max H3 m 3 5 40 4 5 50 Larghezza portone B EZI RZE Gate width L rat Min Med Max 2 0 2 2 2 3 2 5 Velocit ventilatore Fan speed Installazione Collegamento elettrico Installation Electrical connections Pag 06 UNIT COSTRUITA IN CONFORMIT ALLA DIRETTIVA 2006 95 CE ex 73 23 CEE UNIT MANUFACTURED ACCORDING WITH 2006 95 CE STANDARD EX 73 23 CEE ATTENZIONE prima di effettuare qualsiasi intervento assicurarsi che l alimentazione elettrica sia disinserita ATTENZIONE i collegamenti elettrici l installazione dell unit e dei suoi accessori devono essere eseguiti solo da personale specializzato Tenere presente che modifiche elettriche meccaniche e manomissioni in genere fanno decadere la garanzia CAUTION make sure that electrical power to the unit is turned off before makin
14. ENT FUNCTIONS Therefore always follow the operating instructions attached to each remote control It is recommended to make the unit work at the maximum speed for a few hours once installed or in case it hadn t been working for a long time Norme per l utente Messa a riposo a fine stagione Information for the user Reset the end of the season Togliere la tensione all unit tramite l interruttore generale omnipolare posto sulla linea di alimentazione Take current off definitely by depressing the general omnipolar switch placed on the supply line Norme per l utente Usi impropri Information for the user Improper use NON STRATTONARE IL CAVO ELETTRICO E molto pericoloso tirare calpestare schiacciare o fissare con chiodi o puntine il cavo elettrico di alimentazione Il cavo AA NEVER INSERT OBJECTS IN THE AIR ORIENTARE CORRETTAMENTE IL GETTO D ARIA Orientare l unit in modo che il flusso d aria non investa direttamente le persone per lunghi periodi creando sensazioni di disagio CORRECT AIR JET POSITIONING Adjust the unit so to avoid direct air flow blowing continuously onto people L unit animali special TTENZIONE danneggiato pu provocare corto circuiti e danni alle persone NON INFILARE OGGETTI SULL USCITA DELL ARIA Non inserire oggetti di nessun tipo nelle feritoie di uscita dell aria Ci potrebbe provocare ferimenti alla persona e danni all unit Never inse
15. Se l unit dovesse essere venduta o trasferita ad altro proprietario assicurarsi sempre che il libretto accompagni l unit in modo che possa essere consultato dal nuovo proprietario e o dall installatore Il costruttore declina ogni responsabilit per qualsiasi danno dovuto ad un uso improprio dell unit ad una lettura parziale o superficiale delle informazioni contenute in libretto dati tecnici le caratteristiche estetiche i componenti e gli accessori riportati nel presente libretto non sono impegnativi Il costruttore si riserva la facolt di apportare in qualsiasi momento tutte le modifiche ritenute necessarie per il miglioramento del proprio prodotto riferimenti a leggi normative o regole tecniche citate nel presente ibretto sono da intendersi a puro titolo informativo e riferiti alla data di stampa dello stesso L entrata in vigore di nuove disposizioni o di modifiche a quelle vigenti non costituir motivo di obbligo alcuno del costruttore nei confronti di terzi costruttore responsabile della conformit del proprio prodotto alle eggi direttive e norme di costruzione vigenti al momento della commercializzazione La conoscenza e l osservanza delle disposizioni legislative e dele norme inerenti la progettazione degli impianti installazione l esercizio e la manutenzione sono ad esclusivo carico per e rispettive competenze del progettista dell installatore e dell utente ATTENZIONE EI import
16. al modifications Compliance with the safety norms laws applied in the country where the unit is installed Make sure that the technical data concerning the network meet the data indicated on the identification unit label Unit and accessories remote controls etc power supply Check that the line is single phase 230V 1Ph 50Hz and that the voltage remains within the limits Vmin 2195 Vmax lt 265 The work of the unit with voltages that are not within the above mentioned limits makes the guarantee unvalid Make sure that the electrical plant is able to supply in addition to the working current required by the unit also the current required to supply the domestic units already in use CHECK THE EARTHING The electrical safety of the unit is attained only when the unit itself is correctly connected and efficiently earthed according to the existing safety standards When connecting ensure that the earth wire is longer than the live wires so that it will be the last wire to break if the supply cable is stretched thus ensuring a good earth continuity CONNECTION CABLES SPECIFICATIONS Carry out all unit connections using cables of adeguate dimensions for ihe power used in accordance with the local laws in force Their dimensions must be of such dimensions to cause a phase voltage drop of less 376 of the nominal voltage Use HO5V K or NO7V K insulated cables with 300 500 V piped or ducted All cables have to
17. ale di aspirazione dell aria e non devono essere troppo violenti da danneggiare la massa filtrante Se i filtri vengono puliti con acqua prima del loro utilizzo lasciarli asciugare con cura per non compromettere l efficienza del sistema GRUPPO MOTORE VENTILATORE sia il motore sia le ventole ruotano su cuscinetti autolubrificanti e non richiedono manutenzione Accertarsi che la girante sia pulita In caso contrario pulirla mediante soffiaggio di aria compressa e comunque in modo da non danneggiare la girante CONTROLLI ANNUALI Per un regolare funzionamento e buona conservazione dell unit si raccomanda di far effettuare da personale tecnico qualificato le periodiche operazioni di manutenzione almeno una volta all anno Verifica parte elettrica Verificare tutta l apparecchiatura elettrica ed in particolare il perfetto serraggio delle connessioni elettriche Verifica del serraggio di tutti i bulloni dadi e flange che le vibrazioni avrebbero potuto allentare Verificare che il motore non presenti tracce di polvere sporcizia o altre impurit Verificare periodicamente che funzioni senza vibrazioni o rumori anomali che l ingresso del circuito di ventilazione non sia ostruito con conseguente possibilit di surriscaldamento degli avvolgimenti Verificare che la coclea del ventilatore sia libera da sporcizia e qualunque corpo estraneo ROUTINE MAINTENANCE TO BE PERFORMED BY THE USER NOTE Adequate maintenance ensures
18. amage goods Try not to use The unit s components as handholds When lifting bear in mind that the centre of gravity of the unit may be off centre NON SPOSTARE L UNIT DA SOLI SEIL SUO PESO SUPERA I 35 Kg DO NOT HANDLE THE UNIT ALONE IF ITS WEIGHT IS OVER 35 Kg Stoccaggio in cantiere Stocking at site Pag 04 Le unit devono essere immagazzinate al coperto The units must be stocked inside the building Installazione Posizionamento unit Installation Unit location L INSTALLAZIONE DEVE AVVENIRE NEL RISPETTO DELLE NORME VIGENTI Verificare la corrispondenza dell unit e delle sue caratteristiche tecniche rispetto a quanto previsto dal progetto o da altri documenti Non lasciare gli elementi dell imballaggio a portata dei bambini in quanto fonti di pericolo Indossare adeguati indumenti di protezione prima di procedere all installazione dell unit Utilizzare idonea attrezzatura per prevenire incidenti nel corso dell installazione Prima di procedere all installazione si raccomanda di montare sull unit gli eventuali accessori separati seguendo le istruzioni di montaggio contenute in ogni singolo Kit Decidere la posizione di installazione Posizionare l unit su di una struttura solida che non causi vibrazioni e che sia in grado di sopportare il peso della macchina THE INSTALLATION MUST BE ALWAYS COMPLIANT WITH THE CURRENT LOCAL LAWS Check that the unit and its technical characteristics match what
19. ance either asking directly your retailer or applying direct to the manufacturer who will give you the address of the assistance service nearest to you Before calling for service make sure the unit technical data and manual is within reach and namely a Unit model g Product serial no Brief description of the installation type Norme per l utente Ricambi Information for the user Spare parts A A Ai fini della sicurezza e della qualit si raccomanda di utilizzare per le sostituzioni componenti e ricambi originali Per l ordinazione delle parti di ricambio citare sempre il modello dell unit e la descrizione del componente For safety and quality reasons it is recommended to use original spare parts when replacing components To order spare parts you always have to indicate the unit model and the description of the part SOSTITUZIONE COMPONENTI Per la sostituzione dei componenti necessaria una specifica competenza tecnica per cui si raccomanda di rivolgersi sempre ad un Centro Assistenza Tecnica autorizzato ATTENZIONE Tutte le operazioni di sostituzione ricambi devono essere eseguite con l unit non funzionante escludendo l alimentazione elettrica Limiti di funzionamento Operating limits REPLACING PARTS Since specific technical skills are required to replace the spare parts it is recommended to always contact skilled technical personnel WARNING All the replace spare part
20. ante verificare che il progetto e l installazione siano conformi alle norme vigenti Norme EN Norme di sicurezza Regolamenti locali e siano approvati quando previsto dagli enti competenti al controllo in materia Ogni singola unit viene fornita con allegato il proprio specifico ed univoco schema elettrico FARE RIFERIMENTO SOLO AD ESSO DATI TECNICI ED ASSORBIMENTO ELETTRICO Fare riferimento ai valori dati riportati To use the unit correctly and safely the installer the user and the maintenance man for their respective competencies must comply with what is indicated in this manual Store this manual in a dry location to avoid deterioration as they must be kept for at least 10 years for any future reference All the information in this manual must be carefully read and understood as they ll be all very useful for both safe installation and proper use amp maintenance operations Pay particular attention to the operating norms marked with DANGER or WARNING signals as their distepect can cause damage to the unit and or person or objects For any malfunctions not mentioned in this manual contact the local After sales Service immediately Always keep this handbook with the unit This manual is an integral and essential part of the product and must be given to the user Should the unit be sold or transferred to another owner please ensure that the manual remains with the unit for use by the
21. be piped or ducted until they are not placed inside the terminal board of the unit The cables coming out of the pipe duct have not to be subjected to stretch or twist They must be protected from weathering Stranded cables shall only be used in connection with terminating sleeves Make sure that all individual cables are correctly inserted in the sleeve ELECTRICAL CONNECTIONS Carry out the electrical connections according to the wiring diagram All wiring diagrams are subjected to updatings we suggest to make reference to the wiring diagram included in every unit The use of adapters multi plugs and or extension cords is not permitted for unit main power supply t is the installer s responsibility to install the unit as close as possible to the general power switch To prevent short circuits the unit should be connected to the electric supply line by means of an omnipolar magnetothermic switch with a minimum contact opening of 3 mm to choose the suitable switch see electrical absorption as mentioned on the unit s label An omnipolar switch is a Double pole isolating switch i e a switch capable of disconnecting both on phase and neutral This means that when the switch is opened both contacts are disconnected The omnipolar switch or the plug connection by means of cable and plug must be mounted in places easy to reach absorption written on the unit s label EACH CONTROL PANEL CAN CONTROL ONE SINGLE UNIT ONLY
22. che non vi siano danni e che la sigla dell unit corrisponda al modello ordinato Ogni unit viene collaudata in fabbrica prima della spedizione quindi se vi sono stati danni avvisare immediatamente il trasportatore Il trasporto lo scarico e la Movimentazione devono essere effettuati con la massima cura per evitare possibili danneggiamenti utilizzando come punto di presa unicamente la base della macchina ed evitando di usare come punti forza i componenti dell unit Fare attenzione nel sollevamento della unit il cui baricentro pu anche essere fuori asse NON BAGNARE DO NOT WET NON CALPESTARE DO NOT TRAMPLE NON LASCIARE GLI IMBALLI SCIOLTI DURANTE IL TRASPORTO DO NOT LEAVE LOOSE PACKAGES DURING THE TRANSPORT The transport must be done according to the following indications gt Packages must be securely fixed at truck s floor gt Packages must be covered The unit has a special safety packing for transport and delivery which must be kept in good conditions till the unit is positioned on the installation place Make sure that the unit has all its parts as specified in the order Check if there are any damages and if the unit abbreviation is the same as the one of the ordered model Every unit is factory tested before shipment therefore if there are damages report them immediately to the carrier Shipping unloading and handling of the goods are all operations to be carried out very carefully in order not to d
23. d sull etichetta matricolare applicata sull unit on the unit s label Dichiarazione Conformit Conformity Declaration DCF 0304 31021070 R03 Dichiariamo sotto la nostra esclusiva responsabilit che la macchina in oggetto Unit per il riscaldamento condizionamento ventilazione e trattamento dell aria di ambienti civili residenziali commerciali ed industriali marchiata CE conforme alle direttive Europee ed Internazionali di sicurezza L unit conforme a 2006 42 CE Direttiva Macchine ex 98 37 CE ex 89 392 CEE e modifiche 91 368 CEE 93 44 CEE 93 68 CEE 2006 95 CE Direttiva Bassa Tensione ex 73 23 CEE 2004 108 CE Direttiva Compatibilit Elettromagnetica ex EMC 89 336 CEE 97 23 CEE come da Art 3 3 o Art 1 3 6 Direttiva Sistemi in Pressione PED Unit costruita e collaudata in conformit alle seguenti alle seguenti Direttive 92 31 CEE 92 59 CEE e alle seguenti Normative EN 292 1 EN 292 2 EN 294 EN 55014 1 A1 A2 EN 55014 2 A1 A2 EN 61000 3 2 A1 A2 EN 61000 3 3 EN 60555 2 EN 60204 1 EN 62233 EN 60335 1 A1 A11 A12 A13 A14 A15 EN 60335 2 40 A11 A12 A1 A2 A13 e loro emendamenti La Direzione Generale We declare under own responsability that the above equipment complies is Unit for heating conditioning ventilation and air treatment in civil residential commercial and industrial environment
24. e atmospheric conditions happen when in the air there is an abnormal quantity of industrial fumes salts chemical fumes and airborne dust PER PULIRE L UNIT ATTENZIONE Togliere tensione prima di iniziare operazioni di pulizia dell unit Non indirizzare getti d acqua sull unit Pu causare scosse elettriche o danneggiare l unit Non usare acqua calda sostanze abrasive o solventi per pulire l unit usare un panno soffice Evitare possibilmente il funzionamento durante la pulizia dei locali TO CLEAN THE UNIT WARNING Switch off power supply before cleaning unit Do not splash water on the unit It could result in electrical shock or damage to the unit Do not use hot water abrasive powders or strong solvents to clean unit use a soft cloth If possible avoid the working during the cleaning of the rooms h a ES MANUTENZIONE ORDINARIA RISERVATA ALL UTENTE NOTA Una manutenzione accurata sempre fonte di risparmio e di sicurezza Si raccomanda di eseguire almeno ogni mese di funzionamento le seguenti operazioni Pulire semplicemente con un panno umido le parti esterne dell unit FILTRO ARIA Se presente Pulizia ogni 15 giorni La pulizia pu essere effettuata mediante sbattimento del materassino lavandolo con un getto d acqua e detersivo oppure con un getto d aria compressa IMPORTANTE per pulire il filtro i getti di aria o acqua devono essere rivolti in senso contrario a quello norm
25. eed too low Increase fan speed Sense of rotation inverted Chech wiring diagram and electrical connections 4 Excessive noise Air flow too high Reduce air flow Metal components damaged Check state of components and replace damaged parts Rotation parts off balance Balance fan impeller The motor fan does not work Current lack Control the power supply Make sure that The electrical power is on Make sure that Switches and or thermostats are on the right working position Make sure that No objects obstruct the fan rotation Norme per l utente Assistenza Information for the user After sales service Pag 11 A amp ATTENZIONE Per tutte le operazioni di installazione messa in funzione manutenzione ecc avvalersi sempre dell opera di personale professionalmente qualificato WARNING For all installation operations start up etc always consult a qualified service engineer A questo riguardo il costruttore dispone di una rete di Centri di Assistenza che possono essere raggiunti tramite il venditore l agente di zona oppure telefonando direttamente al costruttore che vi fornir l indirizzo del servizio assistenza pi vicino a voi Prima di telefonare al Servizio Tecnico accertarsi di avere a portata di mano la documentazione della macchina e possibilmente Modello unit a Numero di matricola e Descrizione anche sommaria del tipo di installazione You can get technical assist
26. f heating and cooling installation unit for home use according to CORGI Register In any case telephone in Manufacturer office and you can receive all informations Sulla base del progetto di installazione predisporre le linee di alimentazione della energia elettrica Non mettere in funzione l unit senza che essa ed i suoi componenti elettrici siano stati collegati all impianto di terra dell edificio According to the installation project install the electric power lines Always make sure that the unit and all its electrical parts have been correctly earthed prior to starting up the unit Se l unit deve essere smontata proteggere le mani con guanti da lavoro Fare attenzione agli spigoli di lamiera all intemo dell unit Fare attenzione agli spigoli esterni dell unit Tenere libere le griglie di aspirazione If you have to disassemble the unit use special protective gloves Beware of sharp edges inside the unit Beware of roof corners of outdoor units Keep suction grids clear l O Perle unit con ventilatori accessibili versioni ad incasso non mettere in funzione l unit se la stessa non stata montata all interno di un vano accessibile solo con l uso di utensili Le ventole possono raggiungere la velocit di 1000 giri min Non inserire oggetti nell elettroventilatore n tantomeno le mani In the unit with accessible fans concealed versions don t start the unit if the unit itself is not
27. g any electrical connection CAUTION wiring connections unit installation and all accessories have to be made only by specialised installers Please do not forget that warranty cannot be applied in case of Osservare le norme di sicurezza vigenti nel paese di installazione Verificare che le caratteristiche della rete elettrica siano conformi ai dati di targa dell unit Alimentazione elettrica unit ed accessori comandi remoti ecc Verificare che la rete sia Monofase 230V 1Ph 50Hz e che la tensione di alimentazione rientri nei limiti Vmin 2195 Vmax 265 funzionamento dell unit con tensioni non comprese nei limiti suddetti fa decadere la garanzia Assicurarsi che l impianto elettrico sia in grado ad erogare oltre alla corrente di esercizio richiesta dall unit anche la corrente necessaria per alimentare elettrodomestici ed unit gi in uso VERIFICARE IL COLLEGAMENTO DELLA MESSA A TERRA La sicurezza elettrica dell unit raggiunta soltanto quando la stessa correttamente collegata ad un efficace impianto di messa a terra eseguito come previsto dalle vigenti norme di sicurezza Al momento del collegamento il cavo di terra sia pi lungo di quelli sotto tensione Sar l ultimo cavo a strapparsi in caso venga accidentalmente tirato il cavo di alimentazione e rimarr quindi assicurata una buona continuit di terra CARATTERISTICHE DEI CAVI DI COLLEGAMENTO Eseguire il collegament
28. i 3 mm per la scelta dell interruttore pi adatto vedi assorbimenti elettrici riportati sull etichetta matricolare applicata sull unit Si definisce interruttore omnipolare quello con possibilit di apertura sia sulla fase che sul neutro Questo significa che alla sua apertura entrambi i contatti risultano aperti L interruttore omnipolare o la eventuale spina collegamento per mezzo di cavo e spina devono essere posizionati in luoghi accessibili ASSORBIMENTO ELETTRICO Fare riferimento ai valori di assorbimento elettrico riportati sull etichetta matricolare dell unit OGNI PANNELLO COMANDI PU CONTROLLARE UNA SOLA UNITA NOTA Per controllare pi unit oppure una unit con 2 motori si raccomanda di tenere le alimentazioni elettriche dei diversi motori SEPARATE ED INDIPENDENTI Per fare questo si raccomanda di installare 3 relays uno per ogni velocit con contatti indipendenti un contatto per ogni motore da controllare o installare la SCHEDA DI INTERFACCIA accessorio in questo modo qualsiasi anomalia dovesse intervenire in un motore non va ad interferire od influenzare gli altri Il luogo di montaggio del pannello comandi deve essere scelto in modo che il limite di temperatura ambiente massimo e minimo venga rispettato 0 45 C lt 85 U R Il pannello comandi non pu essere montato su una parete metallica salvo che questa sia collegata alla presa di terra in modo permanente electric mechanical and other gener
29. ici per la manutenzione Installation Areas for maintenance MIN 500 Ventilatore Fan L unit deve essere installata in posizione tale da consentire facilmente la manutenzione ordinaria e straordinaria L eventuale controsoffitto deve prevedere la possibilit di accesso all unit per l ispezione dei filtri e dei ventilatori The unit has to be installed in order to allow ordinary maintenance and special maintenance n case of counter ceiling it must always be possible to inspect the unit for filter and fans inspection Dimensioni ed altezze di installazione Dimensions and installation heights Pag 05 Modello Model 10 20 30 40 Numero Ventilatori velocit Fans speed number No No 1 3 173 1 3 1 3 A mm 300 300 330 330 Dimensioni B mm 1 000 1 000 1 050 1 050 Dimensions C mm 390 390 445 445 D mm 130 130 75 75 Peso netto Net weight Kg 25 26 28 29 A Accostando pi unit possibile equipaggiare portoni di qualsiasi larghezza Coupling several units it is possible to equip any width gates LE E 71 1 T Un adeguato schema elettrico con sensore di contatto apertura portone permette di attivare la barriera ad ogni apertura e o solo la barriera di interesse a seconda del grado di apertura del portone A suitable electric wiring with gate opening contact sensor allows to activate
30. ified Personnel Prescrizioni di sicurezza Safety measures Nel corso DELL INSTALLAZIONE MESSA IN FUNZIONE USO E MANUTENZIONE delle unit devono essere rispettate le seguenti norme di sicurezza Observe the following regulations when INSTALLING STARTING UP USING AND SERVICING the units gt L installazione deve essere effettuata in ottemperanza alle vigenti normative del Paese di utilizzo secondo le istruzioni del costruttore da personale professionalmente qualificato o dai Centri di Assistenza autorizzati dal costruttore Solo personale precedentemente addestrato e qualificato pu eseguire le operazioni di installazione e manutenzione dell unit Per personale professionalmente qualificato si intende quello avente specifica competenza tecnica nel settore dei componenti di impianti di riscaldamento e condizionamento In ogni caso telefonando al Costruttore potrete ricevere le informazioni necessarie Installation is to be carried out always strictly complying with the current standards of the country where the appliance is going to be used and following of course the instructions given by the maker Only skilled operators and Authorized Assistance Centers will be entitled to carry out installation Theinstallation and maintenance operations of the unit can be carried out by qualified and trained personnel only Qualified service engineers are those having specific technical experience in the field o
31. iodo di garanzia saranno sostituite o riparate gratuitamente tutte le parti che ad insindacabile giudizio del costruttore risultino difettose all origine per materiale o fabbricazione Sono escluse le spese di trasporto dei componenti ed i costi di manodopera perla sostituzione 2 Eventuali manomissioni della parte elettrica o della parte strutturale delle unit fanno decadere le condizioni di garanzia 3 L installatore resta responsabile dell installazione che dovr essere a regola d arte nel rispetto delle leggi regolamenti e normative di sicurezza vigenti Il costruttore declina ogni responsabilit per eventuali danni che possano direttamente o indirettamente derivare a persone animali e cose in conseguenza alla mancata osservanza di tutte le normative in vigore e di tutte le prescrizioni ed avvertenze indicate sul Libretto Istruzioni di installazione uso e manutenzione 4 L installazione deve prevedere la totale accessibilit delle unit che permetta di eseguire eventuali operazioni successive manutenzione sostituzione di parti sostituzione integrale dell unit ecc in modo semplice rapido e senza rischio di danneggiare parti vicine arredamenti controsoffitti pareti cartongessi coperture ecc Eventuali costi e spese aggiuntive sostenute a seguito della non corrispondenza alla presente prescrizione danno luogo alla non accettazione di richieste di indennizzo o addebiti di qualsiasi natura salvo diversi accordi scritti e
32. iso e Note Note General terms of warranty CGG 0301 60021192 R00 l o Our units are guaranteed against all manufacturing defects In warranty period all parts which manufacturer deem unquestionably to be faulty at origin as a result of materials or manufacturing processes will be replaced or repaired free of charge he transporting components cost and work costs necessary for replacement activities are not included Any tampering with electrical system or structural part of units will result in orfeiture of the warranty terms he installer is installation s responsible which must be carried out professionally and in according to law regulations and legislation concerning current safety standards The manufacturer shall not be held liable for any damage which may directly or indirectly be caused to persons animals or objects as a result of the ailure to observe current norms and all regulations and warnings indicated in the installation use and maintenance Instruction Booklet nstallation must make allowance for full units accessibility this making it possible o perform any subsequent activities maintenance replacement of parts complete replacement of unit etc simply rapidly and without risk of damaging any items in the vicinity of unit furnishings false ceilings walls plasterboard divisions coverings etc Any additional costs or charges necessary for non compliance wi
33. led technical personnel BEFORE THE FIRST STARTUP THE UNIT CHECK THE FOLLOWING POINTS Fastening of the unit at the ceiling or at the wall floor roof etc Hearth wiring and all electrical connections have been tightened Ducts connection Fastening of the inspection panels Available feeding voltage Make sure that all the current norms laws and standards relative to the installation of these units have been observed TO CARRY OUT THE FIRST START UP PLEASE FOLLOW THE INSTRUCTIONS BELOW Put the magneto thermal main switch on Give voltage to the unit gt Summer set the temperature of the room thermostat if any a few degrees lower than the real one gt Winter set the temperature of the room thermostat if any a few degrees higher than the real one tis recommended to make the unit work at the maximum speed for a few hours once installed or in case it hadn t been working for a long time WITH THE UNIT IN OPERATION CHECK Absorbed current and air flow USEFUL INFORMATION It is recommended to inform the user about all the operations necessary to use the unit correctly with particular reference about the importance of periodic tests which must be performed at least once every year by skilled personnel Norme per l utente Uso Information for the user Use Pag 08 AVVIAMENTO E SPEGNIMENTO DELL UNIT ATTENZIONE La prima accensione dell unit di competenza esclusiva
34. ndard costituito da uno scatolone in cartone Nylon e pallets gli accessori vengono forniti sfusi imballati a parte o gi montati sull unit su richiesta Units are shipped with carton boxes Nylon on pallet as standard packing accessories Z z are supplied loose in packed separately or supplied mounted in the unit on request All interno dell unit si trova una busta contenente il manuale di installazione uso e manutenzione ed il certificato di garanzia Su ogni singola unit applicata l etichetta di identificazione riportante e Dati del costruttore e Modello dell unit e Codice di identificazione e Dati tecnici e Schemi elettrici There is an envelope inside the unit containing the installation use and maintenance manual and the warranty documents The identification label bearing the following data is applied on each unit e Manufacturer s data e Modelofthe unit and Identification code e Technical data and Wiring diagram Trasporto Ricevimento Movimentazione Transport Receipt Handling Il trasporto deve avvenire con le seguenti precauzioni gt Adeguato bloccaggio sul pianale del camion gt Protezione del carico con telone L unit viene spedita trasportata e consegnata racchiusa in un apposito imballo di protezione che deve essere mantenuto integro fino al posizionamento sul luogo di installazione Controllare che l unit sia completa nelle sue parti come da ordine Controllare
35. new owner and or installer The Manufacturer declines all responsibility for any damage whatsoever caused by improper use of the unit and a partial or superficial acquaintance with the information contained in this bulletin The technical data styling characteristics components and accessories reported in this manual are not binding The Manufacturer reserves the right to make changes at any time that are considered necessary to improve the product The lawful references standards or technical rules mentioned in this manual are presented merely for the sake of information and should be considered valid as of the date this manual is printed If new regulations or amendments to current laws go into effect this will not obligate the Manufacturer in any way with regard to others The Manufacturer is responsible for ensuring that its product conforms to the laws directives and construction standards in force at the time the product is sold Knowledge and compliance with legal regulations and standards regarding plant design installation operation and maintenance are the exclusive responsibility for the respective competencies of the designer installer and user WARNING It is important to verify that the design and installation conform with current standards Each unit is supplied with its specific univocal wiring diagram STRICTLY REFER TO IT ONLY TECHNICAL DATA AND ELECTRICAL ABSORPTION Refer to values data as mentione
36. ntilation group and Electrical part 1 year Bearing structure Steel components and Cabinet 1 year The units are guaranteed for this period from the date initially started up which the User is obliged to prove e g test start up invoice Otherwise the units are guaranteed or this period from the date of purchase which the User is obliged to prove by means of a fiscally valid document e g purchase invoice or receipt Otherwise he units are guaranteed for this period from the date of manufacture Following any failure taking place replacement unit is excluded Any measures aken to repair or replace parts of unit will not alter the effective start date or duration of the period of warranty specifically extension guarantee is excluded he faulty parts replaced will remain the property of the Seller Once the warranty period has elapsed the replacement of any parts will be charged for in full according to the current tariffs in force Each delivery is disciplined by these general terms of warranty which are considered to be tacitly accepted for all intents and purposes Any eventual exception to the terms of warranty which are established by means of agreement between the parties shall be valid only if confirmed in writing by the Seller The Italian version of these terms will remain the authoritative reference document for any translations thereof Any disputes concerning these terms will fall under the competent
37. o dell unit e di tutti i suoi accessori con cavi di sezione adeguata alla potenza impegnata e nel rispetto delle normative locali La loro dimensione deve comunque essere sufficiente per realizzare una caduta di tensione in fase di avviamento inferiore al 376 di quella nominale Usare cavi tipo HO5V K oppure NO7V K con isolamento 300 500 V incassati in tubo o canalina Tutti i cavi devono essere incassati in tubo o canalina finch non sono all interno della morsettiera dell unit cavi all uscita dal tubo o canalina devono essere posizionati in modo da non subire sollecitazioni a trazione o torsione e comunque protetti da agenti esterni Cavi a trefolo possono essere usati solo con capicorda Assicurarsi che i trefoli dei fili siano ben inseriti COLLEGAMENTO ELETTRICO Effettuare l allacciamento elettrico secondo lo schema elettrico Tutti gli schemi elettrici sono soggetti ad aggiornamento opportuno fare riferimento allo schema elettrico allegato all unit Per l alimentazione generale dell unit non consentito l uso di adattatori prese multiple e o prolunghe dovere dell installatore prevedere il montaggio il pi vicino possibile all unit del sezionatore dell alimentazione elettrica Per proteggere l unit contro i cortocircuiti l unit dovr essere collegata alla linea di alimentazione elettrica Mediante un appropriato interruttore omnipolare magnetotermico con apertura minima dei contatti d
38. rt objects in the air outlet slats This could cause physical injury or damage the unit NON USARE L UNIT IN MODO IMPROPRIO IMPROPER USE OF THE UNIT CONSTITUTES A HAZARD The unit is not designed for any type of animal breeding or similar applications On request NEVER JERK OR TWIST THE POWER CABLE Never pull walk over crush or secure the electric power cable with nails or tacks A damaged cable could cause short circuits or physical injury NON SEDERSI SOPRA L UNIT DO NOT SIT ON THE UNIT OUTLET non va utilizzata per allevare far nascere e crescere Su richiesta versioni speciali es acciaio INOX versions ex stainless steel PER PULIRE L UNIT Non indirizzare getti d acqua sull unit Pu causare scosse elettriche o danneggiarla Non usare acqua calda sostanze abrasive o solventi x per pulire l unit usare un panno soffice TITO CLEAN THE UNIT Do not splash water on the unit It could result in electrical shock or damage to the unit Do no use hot water abrasive powders or strong solvents to clean the unit use a soft cloth NON COPRIRE L UNIT CON OGGETTI O TENDAGGI CHE OSTRUISCANO ANCHE PARZIALMENTE IL FLUSSO DELL ARIA DO NOT COVER THE UNIT WITH OBJECTS OR CURTAINS WHICH MAY PARTIALLY OBSTRUCT AIR FLOW Durante il funzionamento non posare oggetti o panni ad asciugare sulla griglia di uscita aria ne ostruirebbero il passaggio con pericolo di danneggiamento dell unit
39. rtura 1 anno Le unit sono garantite per questo periodo dalla data di primo avviamento che l Utente tenuto a dimostrare ad es con la fattura di collaudo avviamento In caso contrario le unit sono garantite per questo periodo dalla data di acquisto che l Utente tenuto a dimostrare con un documento che abbia validit fiscale es fattura o ricevuta di acquisto In caso contrario le unit sono garantite per questo periodo dalla data di produzione 1 A seguito di intervenuto guasto esclusa la sostituzione dell unit Gli eventuali interventi di riparazione o sostituzione di parti dell unit non modificano la data di decorrenza e la durata del periodo di garanzia in particolare escluso il prolungamento della garanzia Le parti difettose sostituite restano di propriet della Venditrice 2 Trascorso il periodo di garanzia la sostituzione di qualunque componente avverr con totale addebito secondo le tariffe in vigore 3 Ogni fornitura disciplinata dalle presenti condizioni generali di garanzia che vengono considerate tacitamente accettate a tutti gli effetti Qualsiasi eventuale deroga dalle condizioni di garanzia che venisse stabilita concordemente tra le parti avr valore solamente se confermata per iscritto dalla Venditrice 4 Per traduzioni delle presenti condizioni in altre lingue fa fede sempre la traduzione in lingua italiana Per qualsiasi controversia sar competente l autorit giudiziaria di Trev
40. s CE branded in accordance with European and International security directives The unit is in accordance with 2006 42 CE Machine Directive ex 98 37 CE ex 89 392 CEE and amandments 91 368 CEE 93 44 CEE 93 68 CEE 2006 95 CE Low Voltage Directive ex 73 23 CEE 2004 108 CE Electromagnetic Compatibility Directive ex EMC 89 336 CEE 97 23 CEE see Art 3 3 or Art 1 3 6 Pressure Equipment Directive PED Unit manufactured and tested according to the following to the following Directives 92 31 CEE 92 59 CEE and the following Standards Standards EN 292 1 EN 292 2 EN 294 EN 55014 1 A1 A2 EN 55014 2 A1 A2 EN 61000 3 2 A1 A2 EN 61000 3 3 EN 60555 2 EN 60204 1 EN 62233 EN 60335 1 A1 A11 A12 A13 A14 A15 EN 60335 2 40 A11 A12 A1 A2 A13 and related amendments General Management Simboli di sicurezza Safety symbols Pag 02 ATTENZIONE PERICOLO PERICOLO PERICOLO PERICOLO Pericolo Tensione Togliere Tensione Alta Temperatura Organi in movimento ATTENTION DANGER DANGER DANGER DANGER Danger Power Supply Disconnect Power Line Hight Temperature Moving parts gt OBBLIGATORIO OBBLIGATORIO OBBLIGATORIO OBBLIGATORIO Messa a Terra Usare carrello Usare guanti protettivi Solo Personale Qualificato VIETATO COMPULSORY COMPULSORY COMPULSORY COMPULSORY FORBIDDEN Earthing Use undercarriage Use protective gloves Only Qual
41. s operations must be carried out while the unit is turned off disconnecting the electric supplies Alimentazione elettrica unit Power supply unit 230 V 15 1Ph 50Hz Max 265 V Min 195 V Alimentazione elettrica comandi remoti Power supply remote control 230V 15 1Ph 50Hz Max 265V Min 195 V Temperatura di funzionamento aria ambiente Temperature work limits environment air 10 C 50 C Umidit di funzionamento aria ambiente Humidity work limits environment air 10 90 U R R H senza condensa non condensing Smaltimento Waste disposal Pag 12 A fine vita le unit devono essere smaltite nel rispetto delle At the end of its operating life the unit must be disposed normative vigenti nel paese di installazione I materiali che compongono le unit sono Lamiera aluzink Lamiera acciaio inox Lamiera acciaio zincato Rame Alluminio Poliestere Polietilene Acciaio inox Plastica Certificato di Garanzia Warranty certificate according to the regulation in force in the installation country The units are manufactured with the following materials Aluzink plates Stainless steel plates Galvanized steel plates Copper Aluminium Polyester Polyethylene Stainless steel Plastic Condizioni generali di garanzia CGG 0301 60021192 R00 Le nostre unit sono garantite contro qualsiasi difetto di fabbricazione Durante il per
42. schema elettrico ed i collegamenti elettrici 4 Rumorosit eccessiva Portata aria eccessiva Ridurre la portata aria Rottura dei lamierati Verificare l integrit dei componenti e sostituire le parti danneggiate Mancata equilibratura delle parti rotanti Riequilibrare la girante del ventilatore Il motore ventilatore non gira Mancanza di corrente Controllare la presenza di tensione elettrica Controllare che L alimentazione elettrica sia inserita Controllare che Gli interruttori e o i termostati siano nella esatta posizione di funzionamento Controllare che Non vi siano corpi estranei a bloccare la rotazione della ventola WARNING Before to access the unit CUT OUT THE POWER SUPPLY to the unit using the omnipolar switch For anomalies don t hesitate contact the aftersales service immediately FAILURE POSSIBLE CAUSES CHECKS REMEDIES 1 Feeble air discharge Wrong speed setting on the control panel Select the right speed on the control panel Obstructed air filter if any Clean the air filter Obstruction of the airflow inlet and or outlet Remove the obstruction Air distribution system load loss has been underestimated Increase fan speed Sense of rotation inverted Chech wiring diagram and electrical connections 2 Excessive air flow Air distribution system load loss has been overestimated Reduce fan rotation speed and or create load loss 3 Insufficient static pressure Rotation sp
43. th these instructions will lead to refusal of requests for compensation or charges of any kind unless otherwise agreed in writing and confirmed by both the parties he warranty does not cover all parts which may result as being faulty due to negligence carelessness or neglect while using the unit incorrect installation incorrect maintenance maintenance carried out by unqualified and or unauthorised personnel damage caused by accidents damage caused by ransport failures as a result of voluntary or accidental action or circumstances which in any event cannot be referred back to manufacturing defects n compliance with Article 1495 of Italian Civil Code the User will forfeit the right of warranty if the faults are not reported to manufacturer in writing within 8 days of their discovery unless otherwise agreed in writing and confirmed by both the parties he warranty does not cover routine activities for periodic maintenance of units e g cleaning air filters if any and the consequences due to normal wear and ear e g air filters if any Any malfunctions failures faulty components damage directly or indirectly caused to persons animals or objects do not grant the customer the right to defer any payments outstanding Any delay in payment by the purchaser will lead to suspension or cancellation of all warranties he warranty excludes any compensation for period of black out unit Our units are guaranteed for a period of Ve
44. there are no traces of dust dirt or other impurities on the motor Periodically check that it operates without vibrations or abnormal noise that the ventilation circuit inlets are not obstructed causing consequently the possibility of motor winding overheating Check that the fan scroll is free of dirt and foreign bodies Ricerca guasti How to detect failures Pag 10 ATTENZIONE Prima di accedere alla macchina TOGLIERE TENSIONE mediante l interruttore omnipolare posto a monte dell unit Per anomalie non contemplate interpellare tempestivamente il Servizio Assistenza GUASTO POSSIBILI CAUSE VERIFICHE RIMEDI 1 Poca aria in uscita Errata impostazione della velocit sul pannello comandi Scegliere la velocit corretta sul pannello comandi Filtro aria intasato se presente Pulire il filtro aria Ostruzione del flusso d aria entrata e o uscita Rimuovere l ostruzione Perdita di carico del sistema di distribuzione sottostimate Aumentare la velocit di rotazione del ventilatore Senso di rotazione invertito Verificare lo schema elettrico ed i collegamenti elettrici 2 Portata aria eccessiva Perdita di carico del sistema di distribuzione sovrastimate Ridurre la velocit di rotazione del ventilatore e o inserire una perdita di carico 3 Pressione statica insufficiente Velocit di rotazione troppo bassa Aumentare la velocit di rotazione del ventilatore Senso di rotazione invertito Verificare lo
45. tions and release the manufacturer from all responsibilities Before first start up of the unit make sure that the installer has correctly carried out all the operations under his competence Avoid unnecessary supply when the unit is not in use FAILURE OR POOR OPERATION In case of failure and or poor operation Isolate the unit disconnect it from the power supply Do not attempt any repair or direct servicing Call qualified service engineers only Any repair to the units must only be carried out by the manufacturer s authorised service centres using only original spare parts Misapplication of the above might compromise the safety of the unit WARNING To ensure unit efficiency and correct operation it is essential that qualified service engineers carry out annual maintenance following the manufacturer s instructions Norme per l utente Funzionamento Information for the user Operating L unit funziona in modo diverso a seconda del modello di comando remoto a cui viene collegata infatti OGNI TIPO DI COMANDO REMOTO HA FUNZIONI DIFFERENTI Pertanto riferirsi alle istruzioni di funzionamento che accompagnano il comando remoto Si raccomanda di far funzionare l unit alla velocit massima per alcune ore appena montata e dopo lunghi periodi di inattivit The unit is working in a different way depending on the remote control which it is connected to In fact EVERY KIND OF REMOTE CONTROL HAS GOT DIFFER

Download Pdf Manuals

image

Related Search

Related Contents

USB対応 放射線検知器 CPI-UR001 ユーザーズマニュアル  Médée d`Euripide de Jacques Lassalle : entre ici et ailleurs  TPA - Clayton Utz  Nostalgia Electrics LJS-402 User's Manual  Outdoor LP Gas Barbecue Grill Model No. GBC1245W-C  Singer 3323  Panas。m。 取扱説明書 保管用  TEMPTATION 505 SBEA  iHome iP71  Igenix IG9010 space heater  