Home

SERIE MM1 63-71-80-90-100

image

Contents

1. Grandezza IEC Ir HT l IEC size Velocita giri min numero di poli Speed revs min number of poles 750 8p 1000 6p 1500 4p 3000 2p 750 8p 1000 6p 1500 4p 3000 2p 63 0 27 0 22 0 16 0 20 0 15 71 0 33 0 26 0 17 0 30 0 25 0 16 80 0 48 0 47 0 37 0 22 0 44 0 44 0 34 0 20 90 0 61 0 54 0 43 0 32 0 57 0 49 0 39 0 29 100 0 80 0 76 0 59 0 39 0 74 0 69 0 54 0 34 Tab 8 2 COPPIE DI SERRAGGIO Nm TIGHTENING TORQUES Nm T Diametri di filettatura Applicazione Thread diameter Application M5 M6 M8 M10 M12 M16 M20 M24 Connessioni elettriche ottone Electrical connections brass 9 10 20 29 I 1 Connessioni meccaniche acciaio classe 8 8 Mechanical connections steel grade 8 8 6 9 k 255 Tab 8 3 soga COEFFICIENTI CORRETTIVI PER LA POTENZA RESA RATED POWER CORRECTION COEFFICIENTS Coefficiente per la temperatura Temperature coefficient Coefficiente per l altitudine Altitude coefficient Temperatura Ambiente Coefficiente correttivo Altitudine s l m Coefficiente correttivo Environment temperature Correction coefficient Altitude a s l Correction coefficient 40 1 00 1000 1 00 45 0 965 1500 0 97 50 0 93 2000 0 945 55 0 90 2500 0 92 60 0 865 3000 0 89 Tab 8 4 Coefficienti da molt
2. Tab 5 3 2 7 PARTI DI RICAMBIO E DENOMINAZIONE COMPONENTI Nelle eventuali richieste di parti di ricambio precisare il codice del motore la matricola stampigliata in targhet ta e l esatta denominazione dei pezzi rilevabile dalla nomenclatura riportata nei disegni esplosi Utilizzare esclusivamente parti originali per qualsiasi manuten zione o riparazione a 7 SPARE PARTS AND COMPONENT DENOMINATION When requesting spare parts report the motor code the part number printed marked on the motor name plate and the exact denomination of the pieces to be found in the nomenclature given in the following ex ploded view drawings Use only original parts in case of maintenance and repair 8 ALLEGATI 8 ANNEXES soga MASSIMO CARICO RADIALE AMMISSIBILE MAXIMUM RADIAL LOAD Grandezza IEC Carico radiale massimo tiro cinghia Misura espressa in kN Maximum radial load belt pulling measurement expressed in KN IEC size 3000 r p m 1500 r p m 1000 r p m 750 r p m 2 poli poles 4 poli poles 6 poli poles 8 poli poles 63 0 25 0 31 71 0 29 0 39 0 48 80 0 47 0 61 0 71 0 81 90 0 52 0 67 0 78 0 89 100 0 74 0 90 1 08 1 23 Tab 8 1 MASSIMO CARICO ASSIALE AMMISSIBILE MAXIMUM AXIAL LOAD Carico assiale massimo Misura espressa in kN Maximum axial load measurement expressed in kN
3. ever any Soga machine malfunc tions the client is invited to contact our Assistance Service by calling 0039 0444 747700 If the decision is made to return the product we will provide you with an Authorized Material Return RMA number that must be included in the de livery document that accompany material Products that have been returned without following the pro cedure above will be returned to sender In order to obtain coverage under warranty Soga must be con tacted exclusively by its authorized dealers or by its direct customers Requests for repairs received di rectly from final user clients will be considered outside the terms of warranty coverage Prior to per forming repair an estimation will be provided and authorization must be received from the authorized client before proceeding with the repair Shipment All products to be repaired are shipped at the risk and expense of the Client regardless of whether warranty coverage will be claimed or not The client must make sure that the machines sent for repair are in good order and clean We recom mend returning the products in adequate packaging that ensures protection against impact PI CES DE RECHANGE ET SERVICE APR SVENTE Proc dures et adresses de r f rence pour demandes de service apr svente Notre Service Apr svente fournit un conseil technique complet S assu rer pour les demandes de Service Apr svente sous garantie de dis poser des
4. frequenza corrente e velocit nominali Se non diversamente specificato i modelli sono proget tati per temperature ambientali comprese tra 15 C e 40 C e per altitudini non superiori a 1000m s l m valori di rumorosit sono in accordo alla curva A del fonometro secondo la norma CEI EN 60651 La tabel la 8 5 riporta i valori medi della potenza sonora LwA e della pressione sonore LpA in dB A valori sono 4 1 INFORMATION ABOUT SAFETY The User and Maintenance Manual included with the motor provides important indications regarding safety installation use and maintenance This instruction manual has been compiled in accord ance with the dispositions supplied by the Directive 2006 95 EC Low Voltage Directive and by the IEC 60204 1 standard Electrical machine equipment ma chinery safety principles of design specifications and technical principles Strictly observe the instructions given in the User and Maintenance Manual that is provided to indicate the correct conditions for installation use and main tenance in order to prevent motor malfunctions and avoid hazardous situations for the user This product has been designed and constructed solely for the ap plication indicated in this manual Any use not specified in this manual may cause damage to the product and become a source of hazard Moreover all the suggestions deriving from application experience have been included as these are
5. soga 71 80 90 100 SERIE MM1 63 Manuale di uso e manutenzione Use and Maintenance manual soga INDICE CONTENTS 1 INFORMAZIONI SULLA SICUREZZA 4 1 INFORMATION ABOUT SAFETY 4 2 USO 2225 4 2 UC 4 3 TRASPORTO E GIACENZA A MAGAZZINO 5 3 TRANSPORTATION AND STORAGE 5 4 INSTALLAZIONE ccoo orar 6 4 INSTALLATION cocinas cara 6 4 1 Fori scarico condensa 7 4 1 Condensate drain poris 7 4 2 Collegamenti terminali e senso di rotazione 7 4 2 Cabling terminals and direction of rotation A 43 Messa in Servizio iii 8 43 GComnmissi oning 8 5 MANUTENZIONE eese 9 5 MAINTENANCE 9 5 1 Smontaggio e rimontaggio 9 51 Disassembly and re assembiy 9 5 2 A nente 1052 BONOS uma izada 10 5 3 Risoluzione dei problemi 11 53 Trouble shooting 12 6 DEMOLIZIONE E SMALTIMENTO 11 6 DISMANTLING sse 11 7 PARTI DI RICAMBIO E DENOMINAZIONE 7 SPARE PARTS AND COMPONENT COMPONENTI sister 12 DENOMINATION 12 8 ALLEGATI 8 ANNEXES iones 13 Collegame
6. ONUIP eruasu 15 E OS 2 2 5 E 2 5 5 2 Via Della Tecnica 15 e 36075 Montecchio Maggiore VI e ITALY English translation of original instructions www sogaenergyteam com 5 soga Italiano istruzioni originali Soga S p A
7. e Blue LINEA N soga Schema di collegamento motore monofase Wiring diagram of a single phase standard motor standard con interruttore bipolare luminoso e cavo with bipolar switch and cable ONTONIM NIVAZVIOUVN u NMO38 3 Lu m 3018 08022 Vv HS Sla di ca iuj Lu Sz 9 ui X o r o 8 Wo o 0 012 Sx a E ox m OO gt m lt m ac Se a S gt oO N LJ N k aj su Il 1 i ONIONIM ONILYYLS i 1 OLNANVIAAY 1 i c o pa i N me i I i soga Qsoga Disegno esploso Exploded view Fig 8 1 soga Spare parts and component denomination inazione denom io e b Iricam Parti componenti Z8 GEL Lezozi 218021 218021 g62021 111021 892021 48109 UE ejojueAudo 91 869 96v4LL rezul GLILIL ue eua SSv6LL 1v96LL 1v96LL S6S6LL 023611 OSS6LL cg prelys JON gq 9uOUSISOJ opnos qy 29611 1v96LL 1996 ZZ96LL 9 5611 955611 p
8. gli organi accoppiati le connessioni e il collega mento per la messa a terra Verificare che siano state chiuse le protezioni degli organi in movimento che l ingresso dell aria sia libero e che l albero ruoti liberamente Eseguire dunque una prova funzionale per verificare la rotazione Se il moto re stato immagazzinato per un periodo che supera i 3 anni consigliabile cambiare il grasso dei cuscinetti o sostituirli se del tipo auto lubrificato Use power supply cables which have an adequate cross section to bear the current consumption of the motor thus avoiding overheating and or power fail ure IMPORTANT Prevent the cables from transmitting mechanical stress to the motor terminals and having carried out all con nections make sure that the cable glands and the ter minal box cover are well closed so as to have maximum protection Check that the shaft rotates freely Connect the motor by means of a protection device The protection device must not be activated by the mo tor start up current To have a higher starting torque some motors are equipped with centrifugal switch and starting capacitor Connection to the auxiliary devices if provided Thermal protection before carrying out connec tions check the type of thermal protection in stalled for thermistors a special release relay is necessary Some motors on request are provided with thermal protection and switch Anti condensation resistances t
9. neces sary to guarantee the correct safe use of electric mo tors It is requested that all the basic work of preparing the plant assembly installation start up and mainte nance be carried out by qualified staff and be controlled by the technical staff responsible for it The SOGA motor series covered by this manual com ply with the following directives European Directive 2006 95 EC Low Voltage Direc tive European Directive 2004 108 EC Electromagnetic Compatibility Directive European Directive 2002 95 EC RoHS Directive The SOGA motor series has been designed to meet the IEC 60034 standard Rotating Electrical Machines IEC 60072 e EN 50347 Standard output and frame sizes The following standards were used to evaluate the elecromagnetic compatibility IEC 61000 6 2 and IEC 61000 6 3 2 USE The motors of the MM1 63 MM1 71 MM1 80 MM1 90 MM1 100 series with an axial height range from 63 to 100 are intended for industrial and commercial installation The motors ofthe MM1 63 MM1 71 MM1 80 MM1 90 MM1 100 series with an axial height ranging from 63 to 100 are three phase closed type motors On the nameplate are shown the following data nomi nal power voltage frequency current and speed Unless otherwise specified models are designed for ambient temperatures between 15 C to 40 C and altitudes up to 1000 m a s l The noise level is deter mined in accordance
10. togliere i tiranti che bloccano lo scudo flan gia anteriore Agire con due leve sulle orecchie dello scudo flangia anteriore e spostarlo dalla cassa Sfilare il rotore e lo scudo flangia anteriore prestando soga 5 MAINTENANCE Any operation to the motor must be carried out with machine at standstill and disconnected from the power grid Included the auxiliary circuits such as anti condensation resistances WARNING Never and for no reason whatsoever use fluids or water Do not use com pressed air to clean internal electrical parts since this could cause short cir cuits or similar failures WARNING Never touch the motor during opera tion or immediately after the stopping of the unit because some surface parts WARNING might still be very hot It is a good rule to check periodically if the motor is operating without vibrations or strange noises if the current consumption does not exceed the nominal one indicated in the nameplate if the inlet air from the fan cover is not obstructed and that there are no traces of dust oil or other impurities on the motor if power ter minals are well connected to the terminal board and no wear signs are visible if the coupling is in good condi tion and does not exceed the maximum axial and radial load values permitted Any irregularity detected must be promptly corrected The above maintenance operations do not require the motor disassembly But if bearing have to be replace
11. 6 3 Nell installazione e impiego del motore nella macchina finale attenersi alle disposizioni della direttiva 2006 42 CE e alle istruzioni riportate in questo manuale Il Costruttore si impegna a trasmettere in risposta ad una richiesta adeguatamente motivata dalle autorit nazionali informazioni pertinenti il prodotto Montecchio Maggiore li 03 2012 For the installation and use of the motor in the final machine follow the prescriptions of directive 2006 42 EC standard and the instructions in this manual The Manufacturer undertakes to provide information on the product in reply to an adequately motivated request by the national authorities compatibility Soga S p A Door Bess Technical Manager Ing Tommaso Benedetti olAaud os ne un6ulu urs sojonpoud soidoud sns o Jezijenjoe Bled sojep SO Jeoyy pou ouoeJep je EAJasaJ es eog UlessequeA nz Jejjem Bipuejs nz pun ueieisijenpje nz ep win wepue nz BunBipunyueloA euyo pun juawoyy urepef l lp JOA 44994 sep YIS yeyaq eBos unone segud sues synposd ses ep uoneJoi oue p no neanu e asiu ap anbuijod es ep eipeo suep senbnsuejejeo s y JAUIPOLU ep yoJp e anasas es LOS onou Joud INOUJIM sjonpo4d sy Jo o Japso ui ejep v eBueuo o 14 ey san asau e6os os meaud unoje ezues nopoud udoud asesoibiu o aJEUJOI DE sad NEP ip
12. 811 Z09811 Jees woog jut euoiziuJenc 6 X N doyoedeo Buruejs OJUSUIBIAAE Ip 9JOJESUSPUOJ 8 X X Jopoedeo jJueueuuod ejueueuued 9JOJESUSPUOJ VA 28961 08661 086611 006611 719 ebuer pf eouejuy elbue y 29 9976 GG96LL GG96LL 909611 a peus ad eg eouejuy opnos q9 6196 v966LL 796611 518611 Ga ebue 4 gg eouejuy eiBue 4 eg 286411 186211 186211 086211 uonesu duloo auoIzesuaduios p ll uyi G Sr8 LL 969211 969211 068 4 buueeq q uv oll uiosno e BulsnoH 2J0 8 S esse JZ yeys oJaqle l OLPSZL 99 SZL eevezi 266921 OJUAWUIJ9JlJ Ip BD1IPOD OZ OZ 21 OZ axa Reis ees d ere pozsa aau soga RICAMBI ED ASSISTENZA Procedura e indirizzi di riferimen to per richieste di assistenza Il nostro Servizio di Assistenza fornisce completa consulenza tec nica Assicurarsi per richieste di Assistenza in garanzia di disporre dei dati identificativi del motore del suo numero di serie e del numero dell ordine di produzione riportati sulla targhetta La lista dei centri di assistenza autorizzati disponi bile nel nostro sito internet www sogaenergyteam com Nel caso di guasti o anomalie di fun zionamen to delle macchine Soga il Cliente e invitato ad interpellare il nostro Servizio Assistenza telefonando allo 0039 0444 747700 Se dopo tale contatto risultasse necessa ria la restituzione del prodotto il no stro S
13. ERTENZA buona regola verificare periodicamente che il motore funzioni senza vibrazioni o rumori anomali che l assor bimento di corrente non superi quello indicato in targa che l ingresso dell aria dal copriventola non sia impedi to che sul motore non siano presenti tracce di polvere olio o altre impurit che i conduttori di alimentazione siano ben fissati alla morsettiera e non presentino se gni di deterioramento che l accoppiamento sia in per fette condizioni e non superi i valori di carico assiale radiale ammessi Ogni irregolarit rilevata dovr essere prontamente corretta Le manutenzioni sopra descritte non presuppongono lo smontaggio del motore Questo per si rende necessa rio se bisogna sostituire i cuscinetti In tale occasione si dovranno verificare tutti i serraggi di viti e bulloni se condo la tabella 8 3 la resistenza d isolamento e l alli neamento alla macchina accoppiata 5 1 Smontaggio e rimontaggio Eseguire qualsiasi lavoro sulla mac china solo in assenza di tensione Il montaggio e lo smontaggio degli AVVERTENZA organi di accoppiamento e dei cu scinetti devono venire effettuati da personale qualificato con modalit ed attrezzi adatti allo scopo L eventuale smontaggio del motore si esegue liberando il motore dagli organi di accoppiamento con la macchi na operatrice Togliere successivamente il copriventola e la ventola asportando le relative parti di fissaggio Rimuovere la linguetta e
14. Lg eg peus FQN 719 9 exoueisod opnos ep EEBZIL 616211 916211 vL64LL 606 11 206211 poj all ques el Sr08LL tr09LL tr08LL 1208 1108 LLOSLL y en n ur1 21 000611 Buu 1060998 oll uy n VLOLLL VLOLLL VLOLLL VLOLLL GLSLIL GLSLIL XoqJojoede wojesuepuooeuod ejojeos 0L 269211 06v0ZL 076021 Ov 60ZL 076021 076021 pJeoq Jeuiuue BI SMSSION 6 2098 Z09811 2098 11 2098 109811 109811 R s woog jui uolzluueno 8 y Y Jojioede 9Jojesuepuo 289611 086611 086611 00664 98611 66 611 719 aBuely pig e ouejuy eiue 09 S9v6LL GE96LL 6 96LL 909611 Z S6LL ZSS6LL Eg peus Ta eg eouejuy opnos 49 ELIGLI t966LL 966LL 67864 962611 cg gg eouejuy eibuej4 Jeg Z86244 186211 18621 086 11 L16111 926211 uonesu duloo uolzesu duloo IP ll uyi G St9 gESZLL 968 068 GLSZLL 062211 buueeq xYq N 802 on ulosno r Sr8 LL 969211 968 068 LL GISLIL 062211 Buueeq q uv on urosno UISNOH 810 E S esse 2 Ye ys oJaqie L 179221 L6SEZL L6SEZI 21 LVVEZI 226821 ojueul9jl Ip lpoo 92 9ZI 2 92 92 2 uber ender TelDen Tender j bel Jenbero uonduoseq euojzuosea da soga Disegno esploso Exploded view Fig 8 2 soga Spare parts and component denomination inazione denom io e b I ricam Parti componen
15. MPORTANTE Impedire che i cavi trasmettano sollecitazioni mecca niche ai morsetti del motore Al termine di tutte le con nessioni assicurarsi che pressacavi e coprimorsettiera siano ben chiusi per garantire il massimo grado di pro tezione Controllare che l albero ruoti liberamente Effettuare l inserzione del motore in linea tramite un dispositivo di protezione Il dispositivo di protezione del motore non deve scattare a causa della corrente di avviamento Per avere maggiore coppia di spunto alcuni motori sono dotati di disgiuntore e condensatore di avviamento Allacciamento degli ausiliari se presenti Protezioni termiche verificare il tipo di protezione termica installata prima di effettuare il collegamen to per i termistori necessario un apposito rel di sgancio Alcuni motori su richiesta sono provvisti di protezione termica pi interruttore Resistenze anticondensa le resistenze anti condensa scaldiglie devono essere alimentate da linee separate e dotate di protezioni proprie La tensione di alimentazione si trova in targa Non devono assolutamente essere alimentate con il motore in funzione Ventilazione ausiliaria collegare separatamente il motore dell elettroventilatore dal motore prin cipale Predisporre un dispositivo che consenta l avviamento del motore principale solo quando il ventilatore ausiliario in funzione 4 3 Messa n servizio Prima della messa in servizio verificare l allineamento con
16. aber seguido el procedimiento descrito Para la eventual concesi n de la garant a es indispensable que sea exclusivamente el cliente a ponerse en contacto con Soga Solicitudes de reparaci n procedentes directa mente del usuario final se consi derar n en todo caso como NO en garant a Antes de efectuar reparaciones se comunicar un presupuesto y se esperar la autorizaci n del Cliente Expedicon de restituci n al fabri cante para reparaci n La mercanc a devuelta viaja exclu sivamente por cuenta y riesgo del Cliente independientemente de que se conceda o no la reparaci n en garant a Las m quinas tienen que estar en buen estado y limpias El material se debe restituir adecua damente embalado protegiendo el producto contra golpes soga soga GARANZIA La Soga garantisce ai propri clienti le macchine prodotte al suo in terno per un periodo di 18 mesi a decorrere dalla data di fatturazione Soga oppure 12 mesi a decorrere dalla data di prima messa in fun zione quale delle due avviene per prima Si precisa che detta garan zia rivolta ai soli clienti della Soga ai quali direttamente risponde La Soga non riconosce direttamente la garanzia ad alcun soggetto che pur in possesso dei suoi prodotti non li abbia da essa acquistati di rettamente Entro i suddetti termini la Soga si impegna a fornire gratu itamente pezzi di ricambio di quelle parti che a giudizio della Soga o di un suo rappresent
17. able 8 4 Special treatments for particular corrosive environ ments and those with high humidity are available on request For temperatures over 40 C and for environments with temperatures constantly below 15 C it is advisable to contact our Technical Office For overloads services of limited duration or for intermittent duty with frequent start ups it is necessary to contact us and give the in formation on the type of duty the number of start ups every hour and the inertia of the masses connected to the motor Excessive heating of the motor due to overloading prolonged starting up braking or power failure can be avoided by using an adequate overload relay on re quest Special thermal sensors can be installed in the windings for a higher operational safety with particularly heavy duty On request we can supply motors provided with starting devices magneto thermal switches with triggering relay for minimum voltage thermal switches thermistors thermal detectors anti condensation heat ers Fuses do not provide protection for the motor but only protection against short circuits IMPORTANT 3 TRANSPORTATION AND STORAGE Upon arrival carefully examine the motor to check whether it has been damaged during transportation Any visible damage should be immediately reported to the carrier If the motor is not immediately commissioned it should be stored in a sheltered clean and dry place free of vi brations The motor w
18. ante autorizzato presentino difetti di fabbricazione o di materiale oppure a suo giu dizio ad effettuarne la riparazione direttamente o per mezzo di officine autorizzate senza assumersi alcun onere per il trasporto Rimane co munque esclusa qualsiasi altra for ma di responsabilit o obbligazione per altre spese danni e perdite di rette o indirette derivanti dall uso o dalla impossibilit d uso dei prodot ti sia totale che parziale La riparazione o la fornitura sostitu tiva non prolungher n rinnover la durata del periodo di garanzia La garanzia decadr qualora si mani festassero inconvenienti o guasti dovuti ad imperizia utilizzo oltre ai limiti delle prestazioni nominali se il prodotto avesse subito modifiche o se dovesse ritornare disassem blato o con dati di targa alterati o manomessi WARRANTY Soga guarantees the own machines for a period of 18 months starting from the invoice date of Soga or 12 months starting from the first start up whichever occurs first We confirm that warranty is di rected only to Soga customers to which we respond Soga does not grant warranty to those who have not directly purchased the product from the factory in spite of the pos session of it Within the above men tioned terms Soga commits itself to supply free of charge those spare parts that according to its judgment or to the one of an authorized repre sentative appear with manufactur ing or material defects
19. atta nel ri spetto delle norme vigenti Nel caso di demolizione del motore non esistono particolari rischi o pericoli derivati dal motore stesso E opportuno in caso di recupero materiali che vengano separati per tipologia acciaio rame plastica etc Rivolgersi ad un agenzia di smal timento Assicurarsi che nessuna parte del motore ven ga dispersa nell ambiente 6 DISMANTLING Most of motor parts are made of steel cooper and alu minium All materials should be eliminated in compli ance with the local dispositions The motor does not present any particular risk or hazards during disman tling To aid recovery of the material it is best to classify it by type l e steel copper plastic etc When dis mantling the machine contact authorised scrap dealer and ensure that no parts of the motor are dumped in the environment n soga 5 3 Trouble shooting PROBLEM CAUSES WHAT TO DO The motor with no load does not start 1 Feeding lack the OFF position 3 Underfed motor 4 Wrong connections in the terminal box 5 Lack of one phase 6 Faulty capacitor 2 Motor protection switch is in 1 Check connections to the main 2 Check the switch position 3 Check that the feeding line voltage corresponds to motor rated voltage 4 Check all connections 5 Check all three phases fuses and other protections 6 Change the capacitor The motor with load does not start The motor with no
20. d disassembly is necessary On this occasion tightness of all screws and bolts should be checked according to table 8 3 Insulation resistance and alignment to the coupled machine should also be checked 5 1 Disassembly and re assembly Any operation to the motor must be carried out with machine at standstill The assembly and disassembly of the coupling elements and the bearings must be carried out by qualified per sonnel with methods and tools suitable for the purpose WARNING Any disassembly of the motor should be carried out by disconnecting the coupling elements from the drive machine At this point remove the fan cover and the fan tak ing away the relevant fastening parts Remove the key take off the tie rods fastening the D E shield flange Act with two levers on the ears of the D E shield flange and remove it from the housing Take off the rotor and the D E shield or flange taking soga particolare attenzione a non danneggiare l avvolgimen to Per l estrazione dei cuscinetti adoperare un estrat tore Per facilitare l assemblaggio dei nuovi cuscinetti buona norma usare un tubo di ottone o di rame con superficie di appoggio corrispondente all anello interno degli stessi sono da evitare colpi e martellate per non danneggiarli Il montaggio si effettua con sequenza inversa da quella indicata per lo smontaggio In occasione della sostitu zione dei cuscinetti si consiglia di pulire i supporti
21. de restituer le ma t riel dans un emballage ad quat en veillant prot ger le produit contre les chocs e ERSATZTEILE UND RECANBIOS Y KUNDENDIENST ASISTENCIA Prozedur und Referenzadres sen zur Anforderung von Kun dendienstleistungen Unser Kundendienst bietet eine umfassende technische Beratung Zur Beantragung von Kunden dienstleistungen im Rahmen der Garantie sicherstellen dass alle Kenndaten des Motor seine Serien nummer und die Nummer des Pro duktionsauftrags vorliegen welche dem Aufkleber entnommen werden k nnen Die Liste der autorisierten Kundendienst Zentren finden Sie auf unserer Internet Site www so gaenergyteam com Im Falle von Defekten oder Funkti onsanomalien der Soga Maschinen wenden Sie sich bitte an unsere Kundendienstabteilung unter der Telefonnummer 0039 0444 747700 Falls sich ergeben sollte dass das Produkt eingesandt wer den muss erhalten Sie von unserer Kundendienstabteilung eine Num mer f r die autorisierte R ckgabe RMA welche auf den Begleitpa pieren der Ware angegeben wer den muss Waren die nicht nach dieser Pro zedur eingesandt werden k nnen nicht angenommen werden F r die eventuelle Gew hrung von Garantieleistungen ist es erforder lich dass die Firma Soga von ihrem direkten Kunden kontaktiert wird Reparaturantr ge die direkt vom Endbenutzer eingehen k nnen NICHT als Garantieleistungen be handelt werden Vor der Reparatur wird ein Kosten v
22. donn es d identification du moteur de son num ro de s rie et du num ro de l ordre de produc tion indiqu s sur l tiquette La liste des centres apr svente agr s est disponible sur notre site internet www sogaenergyteam com En cas de pannes ou d anomalies de fonc tionnement des machines Soga le client est invit contacter notre Service Apr svente en t l phonant au 0039 0444 747700 Si apr s ce contact la restitution du produit se r v le n cessaire notre Service Apr svente fournira au client un num ro de Retour Mat riel Autoris RMA qui devra tre indiqu sur les documents joints au mat riel Les produits renvoy s sans avoir effectu la proc dure d crite seront renvoy s l exp diteur par le magasin de r ception Pour l accord ventuel de la garantie il est indispensable que Soga soit contact e exclusivement par son client Les demandes de r paration provenant directement de Tutilisa teur final seront consid r es dans tous les cas comme interventions HORS GARANTIE Avant de proc der des r parations un devis sera envoy au Client qui devra commu niquer son acceptation Renvoi au si ge pour r paration En cas de retour de mat riel la marchandise voyage exclusive ment aux frais et aux risques du Client ind pen damment de la concession de l intervention sous garantie Veiller ce que les ma chines soient propres en ordre ll est recommand
23. e so stituire eventuali elementi di tenuta soggetti ad usura Dovendo sostituire qualche elemento di fissaggio as sicurarsi che questo sia dello stesso tipo e classe di resistenza di quello originale Nell eseguire il montaggio assicurarsi che le coppie di serraggio di viti e bulloni siano conformi ai valori ripor tati in tabella 8 3 5 2 Cuscinetti Le macchine in esecuzione standard hanno cuscinet ti a doppio schermo autolubrificanti e non richiedono manutenzione Una volta usurati i cuscinetti vanno sostituiti In tale occasione pulire i supporti e verificare che non siano presenti usure sui mozzi degli scudi flangie Il tipo di cuscinetti utilizzati in ciascun motore riporta tato in tabella 8 6 special care not to damage the winding Use an extractor to remove the bearings To facilitate the assembly of the new bearings it is good rule to use a brass or copper tube with a resting surface corre sponding to the inner ring of the bearings Avoid knock ing or hammering so as not to damage them To assemble the motor follow the instructions in re verse order During the replacement of the bearings it is recommended to clean the housings and replace any sealing element subject to wear For new fastening components make sure that they are of the same type and resistance class of the original element When assembling the motor make sure that the fasten ing couples of screws and bolts comply with table 8 3 5 2 Bearing
24. eight is shown on the nameplate After four years from the date of supply and with the motor stored in good conditions it is advisable to re place the bearings and check if the insulation resist ance is higher than 10 MO Under unfavourable stor age conditions this check time is reduced by half soga 4 INSTALLAZIONE Prima di procedere con l installazione controllare che i dati di targa siano adeguati alle caratteristiche della macchina e del luogo dove si sta assemblando il mo tore Il motore elettrico un componente che viene meccanicamente accoppiato ad un altra macchina sin gola o costituente parte di un impianto ed pertanto responsabilit di chi esegue l installazione garantire la conformit a tutte le prescrizioni e le raccomandazioni delle norme IEC 60204 1 sull equipaggiamento elettri co delle macchine Per accertare la rispondenza alle specifiche di proget to durante il ciclo di produzione e al collaudo finale il motore viene sottoposto ad accurati controlli di qualit ll motore esce dalla fabbrica pronto per l installazione Installare il motore in modo da prevedere la possibilit di ispezioni e manutenzioni durante il funzionamento in ambiente aerato lontano da fonti di calore Evitare che la vicinanza di ostacoli impedisca la ventilazione e che l aria calda in uscita sia di nuovo aspirata L eventuale basamento del motore deve essere piano robusto in modo d assorbire le vibrazioni sufficiente me
25. ervizio Assistenza fornir al Cliente un numero di Rientro Mate riale Autorizzato RMA che dovr essere riportato sui documenti di accompagnamento del materiale Prodotti resi senza aver esegui to la descritta procedura verranno respinti al mittente dal magazzino accettazione Per l eventuale con cessione della garanzia indispen sabile che la Soga sia contattata esclusivamente dal proprio Clien te Richieste di riparazione prove nienti direttamente dall utilizzatore finale saranno in ogni caso consi derate NON in garanzia Prima di procedere a riparazioni verr comunicato un preventivo e si attender l autorizzazione da parte del Cliente Resa della merce per riparazione La merce resa viaggia esclusiva mente a spese e a rischio del Clien te indipendentemente dalla conces sione dell intervento in garanzia Curare che le macchine siano in ordine e pulite Si raccomanda di restituire il materiale entro un imbal lo adeguato curando di proteggere il prodotto dagli urti SPARE PARTS AND AFTERSALES Aftersales procedure and con tact addresses Our Aftersales Service provides a comprehensive technical advise service When requesting assist ance under warranty make sure that the motor identification data is on hand including its serial number and production order as shown on the nameplate The list of author ised aftersales assistance centres can be found on our homepage www sogaenergyteam com When
26. f excessive vibrations or damage of the bearings check the alignment at once as the motor could be mis aligned Power transmission to the drive machine can be done by direct coupling transmission belts gears etc In case of direct connection an elastic coupling or a flexible coupling should be used to avoid the trans mission of any axial thrusts to the bearings In case of coupling by transmission belts install the motor with the shaft parallel to that of the driven machine and on a belt tightening pulley to adjust belt tension Keep in mind that the excessive tension is harmful to bearings life and in the worst case could cause the breaking of the shaft Never exceed the maximum axial and radial loads allowed and when in doubt consult our Technical Office IMPORTANT See fables 8 1 and 8 2 Unless otherwise specified the rotor is balanced dy namically by half a key also the transmission organs should be carefully balanced before assembly Assem bly and disassembly of the coupling organs and the bearings should be carried out by qualified personnel only and using adequate tools At first commissioning check that the insulation resist ance is not lower than 10 MO The insulation resist ance of windings that have operated for long period of time should be over 1 MO the values refer to a room temperature of 25 C and a dc voltage of 500V Lower volgimento non sia inferiore a 1 MA i valori sono riferiti ad una tempera
27. he anti conden sation resistances heaters should be powered with separate power lines and special protections Power supply voltage is shown on the nameplate These resistances must never be powered when the motor is operating Auxiliary fan connect the electric fan separately from the motor terminals Provide a device which allows the motor start up only when the auxiliary fan is activated 4 3 Commissioning Before commissioning check the correct alignment of the coupled elements as well as the correct connec tions and earthing Make sure the protections of live components are closed that the air inlet is free from obstructions and the shaft turns smoothly Perform an operating test to check rotation If the motor has been stored for a period longer than 3 years it is advisable to change the bearing grease or replace the bearings if they are self lubricating type 5 MANUTENZIONE Qualsiasi intervento sul motore deve essere effettuato a macchina ferma e scollegata dalla rete di alimentazio ne Compresi i circuiti ausiliari come le resistenze anticondensa AVVERTENZA Non utilizzare in alcuna occasione liquidi o acqua Non pulire con aria compressa le parti elettriche interne perch potrebbero verificarsi corto circuiti o altre anomalie AVVERTENZA Non toccare il motore durante il fun zionamento e subito dopo l arresto del gruppo in quanto vi potrebbero essere superfici a temperatura ele vata AVV
28. i Su richiesta vengono forniti motori provvisti di dispositivi di avviamento interruttore magnetotermico con rel di sgancio di minima tensio ne protettori termici termistori termorilevatori scaldi glie anticondensa I fusibili non costituiscono una pro tezione per il motore bensi solo una protezione contro i cortocircuiti IMPORTANTE 3 TRASPORTO E GIACENZA A MAGAZZINO All arrivo a destinazione esaminare il motore accurata mente onde verificare che non abbia subito danni du rante il trasporto Eventuali danni visibili devono essere denunciati subito al trasportatore Se il motore non viene posto immediatamente in servi zio dovr essere immagazzinato in un luogo coperto pulito asciutto e privo di vibrazioni Il peso del motore lo si pu leggere nei dati di targa Dopo quattro anni dalla fornitura e con un immagazzi namento in condizioni favorevoli consigliabile sostitu ire i cuscinetti e controllare che la resistenza di isola mento sia superiore a 10 MQ In condizioni sfavorevoli tale tempo si dimezza soga LpA in dB A These values are measured with the motor running at no load rated voltage and 50Hz The tolerance is 3 dB A If not otherwise specified the motors are supplied with IP54 protection class according to IEC 60034 5 stand ard For environmental conditions different from the above mentioned ones the power varies and it is obtained by applying the correcting factors indicated in t
29. ies MM1 63 MM1 71 MM1 80 MM1 90 MM1 100 sono costruiti e collaudati in accordo alle norme di seguito indicate have been manufactured and tested in compliance with the following standards CEI EN 60034 1 IEC 60034 1 CEI EN 60204 1 IEC 60204 1 Risultano conformi alle disposizioni legislative 1 Direttiva 2006 95 CE concernente il ravvicinamento delle legislazioni degli stati membri relative al materiale elettrico destinato ad essere adoperato entro taluni limiti di tensione 2 Direttiva 2004 108 CE riguardante il ravvicinamento delle legislazioni degli stati membri in materia di compatibilit elettromagnetica 3 Direttiva 2002 95 CE sulla limitazione dell impiego di alcune sostanze pericolose nelle apparecchiature elettriche ed elettroniche RoHS La verifica di compatibilit stata condotta in base alle seguenti norme Comply with the legal requirements 1 Directive 2006 95 EC on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits 2 Directive 2004 108 EC on the approximation of the laws of Member States relating to electromagnetic compatibility 3 Directive 2002 95 EC on the restriction of the use of certain hazardous substances in electrical and electronic equipment The following standards were used to evaluate the electro magnetic compatibility CEI EN 61000 6 2 IEC 61000 6 2 CEI EN 61000 6 3 IEC 61000
30. iplicare alla potenza nominale in targa Coefficients has to be multiplied by the rated power shown on the nameplate CUSCINETTI DEI MOTORI IN ESECUZIONE STANDARD STANDARD MOTOR BEARINGS Grandezza IEC IEC size 63 Ti 80 90 100 L Comando Control side 6002 2Z 6202 2Z 6204 2Z 6205 2Z 6206 2Z L Opposto Opposite Side 6002 2Z 6202 2Z 6204 2Z 6205 2Z 6206 2Z Tab 8 5 CUSCINETTI DEI MOTORI CON DISGIUNTORE CENTRIFUGO MOTOR BEARINGS WITH CENTRIFUGAL SWITCH Grandezza IEC IEC size 80 90 S L 100 L Comando Control side 6204 2Z 6205 2Z 6206 2Z L Opposto Opposite Side 6203 2Z 6203 2Z 6203 2Z Tab 8 6 soga COLLEGAMENTI IN MORSETTIERA TERMINAL BOARD CONNECTIONS Motore Monofase Standard Single phase standard motor LINEA F Condensatore Avviamento Capacitor Azzurro Auxiliary Blue Schema motore monofase con termico Single phase motor with thermal protection LINEA F Cond t Protettore termico interno ido i er ore avvolgimento 755 o D Thermal switch in the winding Auxiliary Blue Schema motore monofase con disgiuntore Single phase motor with centrifugal switch Bianco LINEA F LINE F Permanent capacitor Condensatore avviamento permanente Marcia Nero N Faston femmina _ Main Female Faston 7 Black Marcia one Rosso Avviamento Bianco Auxiliary Red Auxiliary White
31. load hardly starts during no load starting it is possible to lock the shaft 1 Wrong connections in the terminal box 2 Underfed motor 3 Defect in the vvindings 1 Check all connections 2 Check that the feeding line voltage corresponds to motor rated voltage 3 Check vvinding resistance The motor vvorks but the rotation is not the one desired 1 VVrong connection on the terminal board 1 Check the connection on the terminal board vvith the vviring diagram on the terminal box cover or on the manual The motor is too noisy it vibrates and or absorbs a higher current than the one stated on the nameplate is too high 2 VVrong connections in the terminal box nominal performances 4 Fauliy centrifugal svvitch If present 5 Faulty winding 1 VVrong feeding or the voltage 3 The motor is vvorking over its 1 Check feeding line voltage and frequency and compare them to the motor ratings 2 Check all connections 3 Reduce the load 4 Change the centrifugal switch 5 Contact our after sales service The motor is noisy and or vibrates but the electric absorption is correct 2 Axial radial loads or wrong belt voltage on the pulley applied to the shaft 3 Faulty bearings 1 Wrong connection to the load 1 Check connections and verify that the application is lined up with the motor 2 Check tables 8 2 and 8 3 and correct the loads 3 Replace the bearings see table 8 6
32. motore 3 Controllare le resistenze dell avvolgimento Il motore funziona ma la rotazione non quella desiderata 1 Collegamento in morsettiera errato 1 Consultare lo schema posto sul coprimorsettiera manuale Il motore fa un rumore eccessivo vibra e o assorbe una corrente notevolmente pi alta rispetto a quella dichiarata in targa 1 Alimentazione errata oppure tensione troppo alta 2 Collegamenti in morsettiera errati 3 Il motore sta lavorando al di sopra delle sue prestazioni nominali 4 Disgiuntore difettoso 5 Avvolgimento difettoso 1 Controllare tensione e frequenza della linea di alimentazione e confrontarla con i dati di targa del motore 2 Controllare che i collegamenti siano conformi 3 Ridurre il carico 4 Sostituire il disgiuntore 5 Contattare l Ufficio Assistenza Soga Il motore fa un rumore eccessivo vibra ma l assorbimento elettrico corretto 1 Errato accoppiamento con il carico 2 Carichi Assiali Radiali o tiro cinghia non corretto 3 Cuscinetti avariati 1 Controllare l accoppiamento e verificare che l applicazione sia in asse con il motore 2 Verificare che i valori siano inferiori alle tabelle 8 1 e 8 2 ed eventualmente correggere i carichi 3 Sostituire i cuscinetti vedi tabella 8 6 Tab 5 3 1 6 DEMOLIZIONE E SMALTIMENTO Il motore costituito in massima parte da acciaio rame ed alluminio L eliminazione dei materiali va f
33. nte rigido da mantenere l allineamento Il motore deve essere sempre ben installato soprattut to se accoppiato direttamente alla macchina condotta In caso di vibrazioni eccessive o guasti dei cuscinetti controllare immediatamente l alineamento che po trebbe risultare disassato La trasmissione di potenza alla macchina operatrice pu avvenire tramite accop piamento diretto cinghie di trasmissione ingranaggi etc Nel caso di accoppiamento diretto si deve usare un giunto elastico o un giunto flessibile che eviti la tra smissione di eventuali spinte assiali ai cuscinetti Nel caso di accoppiamento con cinghie di trasmissione installare il motore con l albero parallelo a quello della macchina condotta e su di un tendicinghia per poter regolare la tensione delle cinghie Tenere ben presente che una tensione eccessiva nociva alla durata dei cuscinetti e nei casi pi gravi pu provocare la rottura dell albero Non superare mai i carichi assiali e radiali massimi consentiti e in caso di dubbi interpellare il nostro Ufficio IMPORTANTE Tecnico vedi tabelle 8 1 e 8 2 Salvo diversa indicazione il rotore equilibrato dina micamente con mezza linguetta Anche gli organi di trasmissione devono essere accuratamente bilancia ti prima del montaggio Il montaggio e lo smontaggio degli organi di accoppiamento e dei cuscinetti devono essere eseguiti da personale qualificato con modalit e attrezzi adatti allo scopo Prima della messa in
34. nti in morsettiera Terminal board connections 15 Disegno esploso DE Exploded view 18 Parti di ricambio e denominazione componenti 19 Spare parts and component denomination 19 Disegno esploso sene 20 Parti di ricambio e denominazione componenti 21 RICAMBI ED ASSISTENZA GARANZIA Dichiarazione di conformiti Exploded view Spare parts and component denomination SPARE PARTS AND AFTERSALES O soga 1 INFORMAZIONI SULLA SICUREZZA Il Manuale Uso e Manutenzione accluso al motore fornisce importanti indicazioni riguardanti la sicurezza l installazione l uso e la manutenzione Questo manuale di istruzioni stato redatto sulla base delle indicazioni fornite dalla Direttiva 2006 95 CE nota come Direttiva Bassa Tensione e dalla norma IEC 60204 1 Equipaggiamento elettrico delle macchine sicurezza del macchinario principi di progettazione specifiche e principi tecnici Attenersi scrupolosamente a quanto riportato nel ma nuale che ha lo scopo di indicare le corrette condizioni di installazione e manutenzione al fine di prevenire eventuali malfunzionamenti del motore ed evitare si tuazioni di pericolo per l utente Questo prodotto stato progettato e costruito esclusivamente per l utilizzo indi cato in questa documentazione Usi non indicati in que sta documentazione potrebbero essere fon
35. or always to its judgment to directly or through an authorized center carry out the repairing without undertaking trans port costs We anyhow exclude forms of responsibility or obligation for other costs damages and direct or indirect loss caused by total or partial usage or impossible usage of the products The repairing or the substitution will not extend or renew the warranty duration Warranty will not be granted whenever break downs or problems may appear be cause of lack of experience usage over the nominal performances if the product had been modified or should return incomplete disas sebled or with modified nameplate data GARANTIE Soga garantit ses clients les ma chines produits par ses soins pour une p riode de 18 mois compter de la date de facturation par Soga ou 12 mois compter de la pre mi re mise en service cela de pende da la condition que si verifie en premi re Nous pr cisons que cette garantie ne s adresse qu aux clients Soga auxquels elle r pond directement Soga ne reconna t pas la garantie aux sujets qui quels qu ils soient bien qu tant en pos session de ses produits ne les lui ont pas achet s directement Au cours des p riodes susmention n es Soga s engage fournir gra tuitement les pieces de rechange des parties qui de l avis de Soga ou d un de ses repr sentants agr s pr sentent des d fauts de fabri cation ou de mat riau ou bien sa discr tion elle
36. oranschlag erstellt und die Autori sierung des Kunden abgewartet Einsenden von produkten an den firmensitz zur reparatur Der Transport der eingesandten Ware geht ausschlie lich auf Kos ten und Ri siko des Kunden unab h ngig von der Genehmigung der Garantieleistung Die Maschinen m ssen sauber in Ordnung sein Das Material muss so verpackt sein dass der Inhalt gegen Sto einwirkungen gesch tzt ist Procedimientos y direcciones de referencia para solicitudes de asistencia Nuestro Servicio de Asistencia pro porciona una completa asesor a t cnica Antes de solicitar Asisten cia en garant a comprobar que se dispone de los datos de identifica ci n del motor de su n mero de serie y del n mero de pedido de producci n indicados en la etiqueta La lista de los centros de asistencia autorizados se encuentra en nues tro sitio internet www sogaener gyteam com En caso de aver as o anomal as de funcionamiento de las m quinas Soga le rogamos que interpele nuestro Servicio de Asistencia llamando por tel fono al n mero 0039 0444 747700 Si tras haberse puesto en contacto fuera necesaria la restituci n del producto nuestro Servicio de Asistencia le facilitar un n mero de Retorno de Material Autorizado RMA que se debe r indicar en los documentos que acompa en el material El almac n de aceptaci n devolve r al remitente los productos que hayan sido enviados al fabricante sin h
37. s Standard machines are provided with self lubricating double shield bearings and do not require any main tenance Once worn bearings must be replaced When replac ing the bearings clean the bearing housing and check that no abrasion is visible on the hubs of the shields flanges In table 8 6 are indicated the bearing type used for every motor size 5 3 Risoluzione dei problemi soga INCONVENIENTI CAUSE COSA FARE Il motore a vuoto non parte 1 Mancanza di Alimentazione 2 Interruttore in posizione OFF 3 Sottoalimentato eventuale intervento della bobina di minima tensione se presente 4 Collegamenti in morsettiera errati 5 Mancanza di una Fase 6 Condensatore difettoso 1 Controllare il collegamento alla rete elettrica 2 Controllare che il salvamotore sia in posizione ON 3 Controllare che la tensione di alimentazione corrisponda con la tensione nominale del motore 4 Controllare che i collegamenti siano conformi 5 Controllare la presenza di tutte le fasi ed eventuali fusibili o altre protezioni 6 Sostituire il condensatore Il motore resta fermo a carico A vuoto stenta a partire durante l avviamento a vuoto si riesce a bloccare l albero 1 Collegamenti in morsettiera errati 2 Sottoalimentato 3 Difetto negli avvolgimenti 1 Controllare che i collegamenti siano conformi 2 Controllare che la tensione di alimentazione corrisponda con la tensione nominale del
38. s engage en effectuer la r paration directement ou par l interm diaire d ateliers au toris s sans soutenir aucun frais de transport Toute autre forme de responsabilit ou d obligation inh rente a d autres frais dommages ou pertes directes ou indirectes derivant de Tutilisa tion ou de l impossibilit totale ou partielle d utiliser les produits reste exclue La r paration ou la fourni ture de remplacement ne prolon gera pas et ne renouvellera pas la p riode de garantie La garantie devient caduque en cas d incon venients ou de pannes li es Finexperience d utilisation audel des limites des performances no minales si le produit a subi des mo difications et est renvoy d mont ou avec les don n es de la plaque signal tique alt r es ou modifi es GARANTIE Die Firma Soga garantiert die von ihr hergestellten Drehstromgenera toren f r die Dauer von 18 Mona te ab dem Datum der billing Soga oder 12 Monate ab dem Datum der Inbetriebsetzung je nachdem was geschieht bevor Die Garantie bezieht sich aus schlie lich auf die direkten Kunden der Firma Soga Die Firma Soga kann solchen Personen die zwar im Besitz ihrer Produkte sind diese aber nicht direkt von ihr erworben haben keine Garantieanspr che anerkennen Die Firma Soga ver pflichtet sich innerhalb der genann ten Lauffristen kostenlos Ersatzteile f r jene Teile zu liefern die nach ihrem Daf rhalten oder nach Beur teil
39. s plazos indicados Soga se compromete a suministrar gratuitamente piezas de recambio de aquellas partes que a juicio de Soga o de su representan te autorizado presenten defectos de fabricaci n o de material o bien a su juicio efectuar directamente su reparaci n directamente o a trav s de talleres autorizados sin aceptar ning n gasto por el trans porte Se excluye en cualquier caso cualquier otra forma de responsa bilidad o de obligaci n por otros gastos da os y p rdidas directas o indirectas que deriven de la utili zaci n o de la imposibilidad de uti lizar los productos tanto total como parcialmente La reparaci n o el suministro sustitutivo no alargar ni renovar la duraci n del periodo de garant a La garant a se perde r si se manifestaran problemas o aver as debidos a inexperiencia o a utilizaci n superando los l mites de las prestaciones nominales si el producto hubiera sido modificado o si se restituyera desmontado o con los datos de la placa alterados o manipulados soga soga Dichiarazione di conformit Il sottoscritto rappresentante dell Azienda 5 soga 5 soga Declaration of conformity The undersigned representative of the Company CE Soga S p A Via della Tecnica 15 36075 Montecchio Magg re VI ITALY DICHIARA DECLARES sotto la propria responsabilit che i motori della serie under its own responsibility that the motors of the ser
40. servizio verificare che la resisten za d isolamento non sia inferiore a 10 MO Per macchi ne che hanno gi lavorato per lunghi periodi di tempo si deve verificare che la resistenza d isolamento dell av 4 INSTALLATION Before proceeding with the installation check that the data shown on the nameplate are adequate to the char acteristics of the machine and the site where the motor is to be installed The electric motor is a component which is mechanically connected to another single ma chine or a machine which is part of a plant and it is therefore responsibility of the installer to guarantee compliance with all the dispositions and recommen dations of the Regulations IEC 60204 1 regarding the electrical equipment of machinery To verify the compliance with the project specifications during the production process and the final testing the motor is subjected to accurate quality controls The mo tor leaves our factory ready for installation Provide the possibility of inspection and maintenance during its operation Install the motor in an aerated room far from heating sources Make sure that near obstacles do not avert ventilation and that hot air com ing out is sucked again If the motor is installed on a basement it should be flat strong enough to absorb vibrations and rigid enough to maintain alignment The motor should always be well installed above all if coupled directly with the driven machine In case o
41. setta o presente in questo manuale Collegare il conduttore di messa a terra sul morsetto con il simbolo Per il collegamento a massa fare ri ferimento a quanto previsto dalle norme locali in materia Collegamenti a massa o di protezione eseguiti in modo errato possono portare a gravi lesioni o al decesso AVVERTENZA Le superfici di contatto devono essere pulite e protette dalla corrosione Il senso di rotazione dipende dal tipo di motore e dal collegamento in morsettiera Per maggiori informazioni andare al paragrafo Collegamenti in morsettiera op pure contattare l Ufficio Tecnico Alcuni modelli sono provvisti di interruttori con bobina di sgancio di minima tensione a richiesta Nel caso in cui la tensione di linea sia molto inferiore al suo valore nominale l interruttore rimane in posizione off soga values indicate that the winding has excessive dan gerous humidity and should be dried by a specialised company Electrical connection should be carried out with the ma chine at standstill disconnected from the power grid in strict compliance with the safety standards given in the IEC 60204 1 4 1 Condensate drain ports If the motor is provided with condensate drain ports closed with a screw cap periodically drain the conden sate this operation has to be carried out with the mo tor at standstill In certain conditions but not in danger areas it might be suitable to remove the closing caps The pro
42. te di danni al prodotto e fonte di pericolo Sono stati riportati inoltre tutti i suggerimenti derivanti da esperienze applicative necessari per garantire l uso corretto e sicuro del moto re elettrico Viene richiesto che i fondamentali lavori di predisposizione dell impianto montaggio installazione messa in servizio manutenzione vengano eseguiti da personale qualificato e controllati dal personale tecnico responsabile Le serie di motori elettrici SOGA coperte da questo ma nuale sono conformi alle seguenti direttive Direttiva europea 2006 95 CE Direttiva Bassa ten sione Direttiva europea 2004 108 CE Direttiva sulla com patibilit elettromagnetica Direttiva europea 2002 95 CE Direttiva RoHS Le serie di motori elettrici SOGA sono stati progettati seguendo le norme internazionali IEC 60034 Mac chine elettriche rotanti IEC 60072 e CEI EN 50347 Dimensioni e potenze standard La verifica della compatibilit elettromagnetica stata condotta in base alle seguenti norme IEC 61000 6 2 e IEC 61000 6 3 2 USO PREVISTO motori elettrici della serie MM1 63 MM1 71 MM1 80 MM1 90 MM1 100 con altezza d asse compresa tra 63 e 100 sono destinati ad installazioni di tipo industria le e commerciale motori della serie MM1 63 MM1 71 MM1 80 MM1 90 MM1 100 con altezza d asse compresa tra 63 e 100 sono trifase del tipo chiuso Sulla targhetta sono riportati i seguenti dati potenza tensione
43. tection level of the motor without closing caps is reduced Some motors manufactured by SOGA are provided with a green condensate drain cap This cap has cap ilary slots which allow the exit of condensate without reducing the protection level Even in this case it is rec ommended to remove periodically the cap and clean it with compressed air so as to avoid that dirt clogs the drain capillary ducts 4 2 Cabling terminals and direction of rotation Connection to the power supply should be carried out following indications shown in the wiring diagram inside the terminal strip cover or given in this manual Earthing is to be carried out to the terminal with the cor responding symbol Follow the local regulations on earth ing for the ground connection An in efficient earth connection can cause WARNING injury or death Contact surfaces should be clean and protected against corrosion The rotation direction depends on the motor type and the wiring diagram For more information see the para graph Terminal board connections or contact the Technical Department Some motor types are provided with minimum voltage relay on request When the line voltage is much lower than the nominal voltage the switch remains in the off position soga Impiegare cavi di alimentazione aventi sezione adeguata a sopportare la corrente assorbita dal motore evi tando sovrariscaldamenti e cadute di tensione eccessive I
44. ti 6 8 461 8968 2628 1628 1968 9628 9628 UOJMS eBnjujueo 10 04 810103 BSIp 8l 998811 86Z8LL 8628LL 99 81l 8681 86Z8LL UONMS peBnyi uso pjerus opnos 9 001 VS 06 08 001 VS 06 08 UOdIJISAC 2UOIZIJISAQ 3244 S3TOd t MOd y S410d Z MOd Z Buu s b s pue pjeius 3 GN siepjou euim uoyws JeBnjujueo pjelys pi usS 3 q N JO 9AISUBUBIJUIOO apo 210LI9 SOd opnos asojuniBsip s d IN euuej opnos e1ojuniBsip euouejsod ojjeurosno ip OAISUDIJUIOO BIIPOD 4 g e qel LELOZI 218021 218021 SELOZI 48109 Ue ejoyuenudog 91 26 26 87 uey eJoJuen m X X UD9NMS ebnyujueo JOJOJ aJounibsig 491 LZ8ZLL 1Z8211 1Z8211 VZ8211 Buueeq 2 soq h ulosnol psi 991811 991911 991911 991911 s plou uyeuue4d 04 yay ms EBNJLRUSO pISIUS opnos 9 0 AGL 8FF6LL 96LL 96LL 896 sg pRUS FAN sg e1ouejsog Opnos eg x O9rr6LL 2696 2696 78G6LL 71 68 PI2IUS TI N 14 68 eoueisoq opnos 91 6 26 616211 816211 pol IL pue vi 08 220811 yi egenBur eL EZOGLI EZOG6LI EZOGLI Z0611 s b s oll uy ZL 667211 66b211 66b211 vOOLLL Jojoedeo ejojeos LL 269211 0760zL 0760zL 0760zL pseog jEuiuue elemas oyy OL 609811 609811 609
45. tura ambiente di 25 C applicando una tensione continua di 500 V Se il valore della resisten za d isolamento inferiore l avvolgimento presenta una eccessiva e pericolosa umidit per cui neces sario essiccarlo ricorrendo ad una ditta specializzata Il collegamento elettrico viene eseguito a macchina fer ma con impianto di alimentazione scollegato dalla rete elettrica rispettando scrupolosamente le istruzioni di sicurezza precisate nella norma CEI EN 60204 1 4 1 Se il motore provvisto di foro scarico condensa chiuso da un tappo a vite procedere periodicamente allo scarico della condensa da effettuarsi con motore spento In certe condizioni e comunque non in zone di pericolo pu essere opportuno eliminare gli eventuali tappi di chiusura Il grado di protezione del motore sen za tappi di chiusura risulta diminuito Taluni motori di produzione SOGA hanno un tappo sullo scarico condensa di colore verde Tale tappo ha del le fessure capillari che permettono la fuoriuscita della condensa senza diminuirne il grado di protezione An che in questo caso si consiglia comunque di togliere periodicamente il tappo e pulirlo con dell aria compres sa onde evitare che particelle di sporco chiudano i con dotti capillari di scarico Fori scarico condensa 4 2 Collegamenti terminali e senso di rotazione Il collegamento all alimentazione dovr avvenire con le indicazioni riportate sullo schema posto all interno del copriba
46. ung eines autorisierten Vertre ters Fertigungs oder Materialfehler aufweisen oder nach ihrem Daf r halten direkt oder mittels autorisier ter Werkst tten die entsprechende Reparatur durchzuf hren wobei die Transportkosten nicht zu ihren Lasten gehen Von der Garantie ausgenommen ist jede andere Form der Haftung oder Verpflich tung f r weitere Kosten Sch den und direkte oder indirekte Verlus te die infolge des Gebrauchs oder des totalen oder teilweisen verhin derten Gebrauchs der Produkte entstehen k nnten Reparaturen oder Ersatzlieferungen verl ngern oder erneuern in keinem Fall die Laufzeit der Garantie Der Garan tieanspruch verf llt Wenn Proble me oder St rungen auftreten die auf Unerfahrenheit oder Gebrauch ber die Grenzwerte der Nennleis tungen hinaus beruhen bzw wenn das Produkt ver ndert wurde oder wenn es in zerlegtem Zustand oder mit ver nderten oder besch dig ten Typenschildern zurtickgesandt wird GARANT A Soga garantiza a sus clientes las maquinas producidos por ella por un periodo de 18 meses a partir de la fecha de factura de Soga o bien 12 meses a partir de la fecha de pri mera puesta en marcha la primera que se produzca Se especifica que esta garant a es v lida exclusivamente para los clientes Soga a los que responde directamente Soga no reconoce directamente la garant a a ning n sujeto que a n poseyendo pro ductos suyos no se los haya com prado directamente En lo
47. with curve A of the sound level meter as per EN 60651 Table 8 5 shows the average values of sound power level LwA and pressure level stati rilevati con motore funzionante a vuoto alimentato alla tensione nominale a 50Hz La tolleranza pari a 3 dB A motori se non diversamente specificato sono protetti secondo il grado IP54 della norma IEC 60034 5 Per condizioni ambientali diverse da quelle sopraindi cate la potenza nominale del motore varia In questo caso necessario applicare i fattori correttivi indicati nella tabella 8 4 Su richiesta si eseguono trattamen ti speciali per ambienti particolarmente corrosivi e ad elevata umidit Per temperature maggiori di 40 C e per ambienti con temperature costantemente inferiori ai 15 C consi gliabile consultare di volta in volta i nostri Uffici Tecnici Per sovraccarichi servizi di durata limitata o per servizi intermittenti con frequenti avviamenti occorre interpel lare il nostro Ufficio Tecnico fornendo le informazioni riguardo il tipo di servizio il numero degli avviamenti orari l inerzia delle masse accoppiate al motore L eccessivo riscaldamento del motore per sovraccari chi avviamenti o frenature prolungate o per mancanza di una fase di rete viene evitato con l impiego di un appropriato salvamotore Per aumentare la sicurezza di funzionamento in presenza di servizi particolarmen te gravosi si possono installare negli avvolgimenti dei particolari sensori termic