Home
Combinatore telefonico GSM con messaggi vocali pre
Contents
1. 9999 TDX16 with the screw in dotation ATTENTION connect sai crime vi se Chiave elettronica The base of TDX16 can be mounted on a standard wall mounted boxtype 503 For the anti theft protection fixing Use any GSM phone for delete the access code PIN CODE that enables the use of the SIM CARD Installation 2 2 Connection with Serie XM seem 000 000 G0 00 H 1 central unit SA COM EL OUT IN 009 011 012 i 009 D 1 1 1 i 12 AUXI 010 1 I I Ly V Hie 00000 00000 C NA NC INT IN IN OUTI 1 2 1 TDX16 ATTENTION Programming from XM consolle To communicate from XM to TDX16 the status of the network you need to enable an exit for example the logical output on console and type 012 XM MASTER code is displayed 3 Stato Rete 000 000 000 000 press or 3 Stato Rete gt 000 000 000 000 insert the output 012 012000000000 3 Stato Rete confirm with or and exit from programmation by pressing most times the button a TDX16 user s manual 3 Programmation 5X 6X7X8 The programmation the telephone dialer is allowed only by local keyboard typing the master code default is
2. emen inie ibai 10 3 6 Ripristino impostazioni di 10 3 7 RIAVVIO COmbInaltore ccce 10 3 6 EE 10 Capitolo 4 Funzionamento 11 4 1 Informazioni Sul 11 4 2 Descrizione generale del 2 12 4 3 Codice COMANDI zeiten ete etd hn eG ce i ve d Uo da 13 4 3 1 Inserimento disinserimento 13 4 3 2 Modifica codice 14 A A Ciclidi eee EE d dee eU i 14 4 5 Controllo 15 ALG O SMS E 16 4 7 Interrogazione credito residuo tramite SMS e reinvio SMS ricevuti 16 Introduzione 1 1 1 1 2 Introduzione Caratteristiche funzionali Combinatore telefonico completamente pre programmato con messaggi vocali di allarme antifurto assenza rete e tutti i men guida vocali Risponditore vocale con messaggi guida pre registrati Comandi remoti per Ins Dis e Blocco ciclo chiamate Codici accesso programmazione e utente Display alfanumerico con visualizzazione stato impianto e presenza rete Uscita comando centrale con funzionamento ad impulsi SerieXM o ON OFF SerieTM Modulo GSM Quad Band Tamper di protezione antiapertura Messaggi vocali pre registrati SMS pre impost
3. Premere 7 per inserire oppure Premere 9 per disinserire se l impianto gi inserito Premere 0 per STOP CICLI NOTA Per terminare l ascolto ambientale possibile digitare Con il comando lt 0 gt si arresta il ciclo di chiamate si chiude la telefonata corrente Al termine della chiamata sul display si visualizza 25Y Fine Chiam Imp INSERITO 15 TDX16 Manuale dell utente 4 6 InvioSMS Quando parte un ciclo di allarme vengono inviati per prima cosa gli SMS verso tutti i numeri abilitati a tale servizio nella rubrica messaggi sono a seconda dei casi Impianto in allarme rete OK Impianto in allarme assenza rete Impianto inserito assenza rete Impianto disinserito assenza rete Bom NOTA L SMS viene inviato PRIMA di effettuare la telefonata e i tentativi di chiamata sono 3 per ogni numero di telefono 4 7 Interrogazione credito residuo tramite SMS e reinvio SMS ricevuti Per conoscere il credito residuo sulla SIM inserita nel TDX16 seguire la procedura descritta di seguito e Inviare un SMS al combinatore dal proprio cellulare con la seguente dicitura SMS XXXXXX YYYYYYY A b Numero di telefono del Testo SMS Centro Servizi operatore SIM Esempi numeri centri servizi di alcuni operatori OPERATORE TESTO SMS TIM SMS 40916 PRECRESIN VODAFONE SMS 404 TRAFFICO WIND 1 SMS 4155 Saldo Il combinatore invier un
4. the step is easy just enter in Address book and press one of the buttons we have RUBRICA Cancella Press G select the phone number you want to delete with w 4 example Number 03 will displayed Numero 03 122668899 press the button G D displayed Vuoi Cancellare 7 SI 9 NO pressing the button For a few seconds will be displayed CANCELLATO to exit the submenu Delete numbers just go back by pressing the button ESO for more times NOTE If during programming the keyboard is not used for more than 1 min the dialer exit of this phase 3 2 Parameters 5X6X7X8X1 X2 3 2 1 Relay OUT configuration Lets you choose the behavior of the output relay to allow the insertion of central alarm system In the run TO STATE suitable for Central TM type or PROTEC the output relay reverses output OUT1 to each command while IMPULSE OPERATION suitable for SerieXM or XR the relay closes the contacts C NA of OUT1 for about 1 sec and then returns to resting conditions Once you enter the menu press the button 25r you displayed Conf Relay OUT A STATO or Conf Relay OUT A IMPULSO for change the configuration of the output settings just press 1 TDX16 user s manual 3 2 2 Netalarm configuration Press for visualize Conf All RETE Allarme su OV or Conf All RETE Allar
5. 5X6X7X8 followed by G or by opening the dialer and pressing the button P1 for about 15 seconds Once inside is displayed Indicates the intensity of the signal 1 min 31max 1 Address book 2 Parameters 3 Codes 4 Common Messages 5 Restoration 6 Info 7 Restart 8 Test ABCD Service Provider 1 Rubrica 16 telephone number call Configure the operating mode of the Relay OUT1 In State TM PROTEC or pulse XMseries TM600P XR500 Configuration recognition on Network IN K2 Modify of MASTER code and COMMANDS code Make atest call Reset the codes MASTER and command and the entire phone book Visualization of the model Firmware and IMEI of GSM module Restart the telephone dialer Make a test call 3 4 Address book 5X 6X7X8X5X1 3 1 1 Telephone numbers insered Once you enter the menu press em is displayed press the button WD is displayed press the button WD is displayed RUBRICA Inserisci Numeri Numero 01 Non Programmato Numero 01 gt atthis point we must insered the phone number maximum of 32 digits Numero 01 123456789 gt Once inserted to confirm by pressing only the key and immediately is displayed Invio SMS all 7 SI 9 NO When deciding if associed the SMS to number just confirm by pressing the button 7 or 9 NO 6 Programmation 3 1 2 Delete numbers To delete a phone number
6. Codes and user programming access Alphanumeric Display with viewing system status and network presence Central command output with pulsed operation SerieXM or ON OFF SerieTM Quad Band GSM Module Anti opening tamper protection Pre recorded voice messages Pre set SMS for net presence anti theft alarm status and presence indication GSM signal strength and service provider Remote listening Delay Timer absence reporting network 10 minutes Credit reading forwarding of incoming SMS to the numbers in the address book and reset of the device from the menu without power supply Technical charcteristics Channels 2 Power supply voltage 13Vdc 1096 Max current consumption 400mA Address book 16 numbers Antenna ANTGSMX included INT Anti theft inserting status Inputs K1 Alerm status K2 Net presence Output Arming Disarming command External onnector ABS Dimensions W 107mm Dimensions H 140mm Dimensions D 26mm TDX16 User s manual 2 2 1 Installation HiltTron Connection Serie TM and Protec No electronic key Burglar central unit SSSL to voltage net Int Sir 04Vdc max To connect 12Vcc Chiave T O TitaMA 10 With electronic key Burglar central unit 1 1 1 0
7. AND Code by default 1 2 X3 X4 at difference from the MASTER code allows you of enable or disable of the burglar alarm system or change the COMMAND CODE 4 3 1 Arming Disarming 1X2X3X4XsX1 Once you have typed the COMMAND Code press in sequence keys Displays Imp DISINSERITO 7 INS 9 DIS press the button dialer command the insertion of the burglary system 7 with th button not perform any operation If you visualize Imp INSERITO 7 INS 9 DIS Is possible utilize the button to operate the disconnection of the system While using the button gp not command any operation To exit this menu press the key 13 TDX16 users manual HILTFON 4 3 2 COMMANDS code modify you have typed the COMMAND Code press in sequence the keys st and 2 is displayed SELEZ CODICE CODICE COMANDI for change the COMMAND code press the button I si visualizza CODICE COMANDI Insert the code you want it displayed SELEZ CODICE CODICE COMANDI NOTE Accessing the COMMANDS cannot change the MASTER code 4 4 Alarm Cycles When an event of alarm the cycle of calls The display will show 25 XChiama gt gt gt 1234567890 In case of Network Failure event timer part 600 seconds 10 min before it is carried out the cycle of calls In case of network recovery call cycle does not run Once connected you sho
8. O lt HILTF On TDX16 Combinatore telefonico GSM con messaggi vocali pre registrati MANUALE PER L UTENTE TDX16 Manuale dell utente Capitolo 1 4 42 444 4402 3 1 1 Caratteristiche crei corti ern 3 1 2 Caratteristiche 3 Capitolo 2 Installazione iuniiiiii ii 4 2 1 Schema di collegamenti Serie TM e 4 2 2 Schema di collegamenti con Serie XM n 5 Capitolo 3 Programmiazione 6 Sl EUDEFICO ede tr a esa ded dando 6 3 1 1 Inserimento Numeri 6 3 1 2 Cancellazione Numeri 7 3 2 2 been eden tede d a 7 3 2 1 Configurazione Relay OUT 7 3 2 2 Configurazione Allarme 8 3 2 3 Funzione abilitazione disabilitazione inoltro SMS 8 3 3 Codici MASTER e COMANDI 8 3235 Codice MAS TER ccce reta x e aa 8 3 3 2 Codice COMAND ccccssssssecssssssecesceseseessceserseeesseesseessseeensesseseesaness 9 3 3 4 Messaggio Vocale Comune 2 9 SEMI 10 3 6 Informazioni sul TDX16
9. SMS col testo immesso precedentemente yy yvy vy al numero di telefono del centro servizi dell operatore di telefonia xx XX XX Il combinatore attendera per circa 50 secondi la risposta dal server dell operatore TIM VODAFONE WIND ecc La risposta sara inviata al numero da cui stato inviato l SMS Qualsiasi altro SMS ricevuto dal combinatore telefonico verr inviato al primo numero se presente memorizzato nella rubrica del TDX16 promozioni bonus punti ecc 16 L o 2 T HILTON TDX16 GSM phone dialers with prerecorder vocal messages USER S MANUAL TDX16 user s manual Index Chapter 1 4 424 424422 2 3 1 1 Functional characteristics oot ret teo ri ct ema eet eee eed ena aves 3 1 2 Technical characteristics eet bent ir RR RR RR E ea xS 3 Capitolo 2 Installation 4 2 1 Connection Serie TM and Protec nanasa aee 4 2 2 Connection with Serie XM 66 em enne nnn 5 Chapter 3 ProgrammationN lai 6 3 1 Address DOOK c t e e ERR XR dx Rd 6 3 1 1 Telephone numbers 6 3 1 2 Delete numbers tete tre er ri 7 9 2 Paramelets ees te eoa Ne UR e YR ENTERA f 3 2 1 Relay OUT configuration iii 7 3 2 2 Net Alarm conf
10. X16 Manuale dell utente 3 2 2 Configurazione Allarme Rete Premere per visualizzare Conf All RETE Allarme su OV oppure Conf All RETE Allarme su 12V Per passare da una configurazione all altra premere i tasti GE AD Con Allarme su OV adatto per impianti con centrali Serie il timer comincia il conteggio quando viene a mancare la tensione sull ingresso IN K2 mentre con Allarme su 12V adatto per impianti con centrali Serie XM il countdown comincia quando si presenta una tensione sull ingresso IN K2 Per terminare la configurazione premere il tasto ESC 3 2 3 Funzione abilitazione disabilitazione inoltro SMS Con questa funzione abilitata il combinatore invia tutti gli SMS ricevuti al numero inserito alla posizione numero 1 della rubrica Premere per visualizzare Inoltro SMS Abilitato oppure Inoltro SMS Disabilitato per cambiare configurazione usare i tasti WAD 3 3 Codici MASTER e COMANDI SCOT EG In questo men possibile cambiare i Codici MASTER e COMANDI Una volta entrati nel men premere il tasto 3 si visualizza 3 3 1 Codice MASTER Il codice MASTER permette di accedere alle funzioni del men che oltre programmare il TDX16 consente anche di effettuare eventuali modifiche Infatti per cambiare i codici basta confermare con WAD e si visualizza SELEZ CODICE CODICE MASTER a
11. ati per stato presenza rete stato antifurto e presenza allarme Indicazione dell intensit di segnale GSM e del gestore telefonico Ascolto ambientale da remoto Timer ritardo segnalazione assenza rete 10minuti Lettura credito inoltro degli SMS ricevuti ai numeri in rubrica e reset del device da men senza togliere alimentazione Caratteristiche Tecniche Canali 2 Tensione nominale di alimentazione 13Vcc 10 Assorbimento max 400mA Rubrica 16 numeri Antenna ANTGSMX inclusa INT Stato inserimento antifurto Ingressi K1 Stato allarme K2 Presenza rete Uscita Comando Inserimento Disinserimento Contenitore esterno ABS Dimensioni L 107mm Dimensioni A 140mm Dimensioni P 26mm TDX16 Manuale dell utente 2 2 1 Installazione HiltTron Schema di collegamenti Serie TM e Protec Senza chiave elettronica Centrale antifurto Da collegare a unriferimento di Int Sir tensione di rete 24Vcc max Eo 12Vcc Chiave Con chiave elettronica Centrale antifurto Da collegare a un riferimento di tensione di rete 24Vcc max T Int Sir Eod 12Vcc Chiave Chiave Elettronica SS lt S lt Ss TDX16 Il fondo della consolle
12. atore comanda l inserimento della centrale mentre con il tasto 0 non esegue nessuna operazione Se invece si visualizza Imp INSERITO 7 5 9 DIS possibile utilizzare il tasto 9 per comandare il disinserimento dell impianto mentre con il tasto non si comanda nessuna operazione Per uscire da questo men basta premere il tasto Esc 13 TDX18 manuale dell utente HILTFON 4 3 2 Modifica Codice COMANDI 2 3 4 2 Una volta digitato il Codice COMANDI premere in sequenza i tasti e 2 si visualizza SELEZ CODICE CODICE COMANDI per cambiare il Codice COMANDI premere il tasto C 1 1 Si visualizza CODICE COMANDI inserire il codice desiderato si visualizza di nuovo SELEZ CODICE CODICE COMANDI NOTA Accedendo con il Codice COMANDI non possibile modificare il Codice MASTER 4 4 Cicli di Allarme Quando si verifica un evento di allarme parte il ciclo di chiamate Sul display si visualizza 25 gt gt gt 1234567890 In caso di evento Assenza Rete parte il timer di 600 secondi 10min prima che venga effettuato il ciclo di chiamate In caso di ripristino della rete il ciclo di chiamate non viene eseguito Effettuata la connessione si visualizza 25 Connesso gt gt gt 1234567890 si ascolter Impianto in allarme e o assenza rete a seconda dell evento inserire codice s
13. bout 50 seconds the response from the server of the operator TIM VODAFONE WIND etc to the number from which the request was made Any SMS received from the phone dialler will be sent to the first number if any stored in the phonebook of TDX16 promotions bonus points etc 16 738ADIE 4 00
14. e inserito correttamente solo CODICE COMANDI passa alla fase successiva GESTIONE REMOTA che verr descritta in seguito 25 Connesso GESTIONE REMOTA altrimenti se risulta incorretto dopo circa 30sec la chiamata termina Il ciclo di allarme prosegue con la chiamata al numero successivo inserito nella rubrica In ogni ciclo il combinatore effettua 3 tentavi per raggiungere l utente inserito nella rubrica dopodich termina il ciclo 14 Funzionamento 4 5 Controllo Remoto Il controllo remoto permette di interrogare o comandare attraverso il TDX16 l impianto di allarme ad esso collegato E possibile attivare questa modalit sia durante una chiamata di allarme come descritto in precedenza sia chiamando direttamente il combinatore da un telefono in grado di inviare toni DTMF Quando la connessione si attiva sul display comparir 25 Connesso Imp INSERITO si ascolta il messaggio pre registrato Inserire Codice solo Codice COMANDI se inserito correttamente si attiva la gestione remota altrimenti se risulta errato dopo circa 30sec la chiamata termina Immesso il codice sul display comparira 25 Connesso GESTIONE REMOTA Si ascolter il messaggio Impianto Inserito oppure Impianto disinserito seconda dello stato di inserimento della centrale collegata Rete OK oppure Assenza rete Premere 5 per ascolto ambientale
15. iguration 2 crederet ee tiani 8 3 2 3 Enable disable SMS forwarding 8 3 3 MASTER and COMMANDS ocode sss en 8 3 31 MAS TER COGO eniti Eins 8 3 3 2 COMMANDS 9 3 4 Customizable common vocal 9 3 5 10 3 6 Reset default 9 10 3 7 Telephone dialer reDbOot 2 rere tr e EE SE RE 10 Chapier4 Operallonica exu 11 4 1 Display information t te aa gaa TEE Ende 11 4 2 General description of operation 12 4 3 COMMANDS 6 2 Enea i 13 4 3 1 Arming Disarmilfig cia 13 4 3 2 Commands code 14 4 4 Alarm CYCles 14 4 5 Remote COMO n ieri 15 4 6 SMS sendlitig reo 16 4 7 SMS residual credit and sending SMS received 16 Introduction 1 1 2 Introduction Functional characteristics Completely pre programmed phone dialer with anti theft alarm voice messages no network and all voice guidance menu Pre recorded Guide voice responder messages Remote controls for on off and call loop block
16. ione 3 1 2 Cancellazione Numeri Per eliminare un numero telefonico l operazione da effettuare semplice basta entrare in Rubrica e premere uno tra i tasti w vremo RUBRICA Cancella premere EDA selezionare con W Bi numero di telefono che si vuole eliminare es Numero 03 si visualizza Numero 03 122668899 premere sempre il tasto visualizza Vuoi Cancellare 7 SI 9 NO premendo il tasto Thi visualizza per qualche istante CANCELLATO per uscire dal sottomen Cancella Numeri basta tornare indietro premendo pi volte il tasto NOTA Se durante la programmazione la tastiera non viene utilizzata per un tempo superiore ad 1 min il combinatore esce da questa fase 3 2 Parametri 5X 67K 8X 2 3 2 1 Configurazione Relay OUT Permette di scegliere il comportamento del rel di uscita per consentire l inserimento della centrale antifurto Nel funzionamento A STATO adatto per centrali tipo TM o PROTEC il rel di uscita inverte l uscita OUT1 ad ogni comando mentre nel funzionamento A IMPULSO adatto per le centrali SerieXM o XR il rel chiude i contatti di OUT1 per circa 1sec e poi ritorna in condizioni di riposo Una volta entrati nel men premere il tasto oppure si visualizza Conf Relay OUT A STATO oppure Conf Relay OUT A IMPULSO per cambiare la configurazione dell uscita basta premere ED TD
17. ipristino OK with pressing the button 9 itexits the menu without reset 36 TDX16 Information DIETA ANY To proceed simply use the keys w and displays Model TDX16 Y Rel Firmware 738ESW 2 00 00 0000000000000000 37 Telephone dialer reboot This function restarts the dialer you can be useful to force a new S 5 Xe TY EI on amp GSM network Once you enter the menu press you displayed 25 Indicates the intensity P ofthe signal from 1 at 31 7 Reset ABCD Service Provider 3 4 Test 5X6 7 X8 X35X4 Once you enter the menu press 4 you are viewing Inserire Numero 10 HILTON Insert a phone number and after press the button is visualized 25 Chiama Indicates the intensity P of the signal from 1 at 31 1234567890 Operation Number telephone answering the call will show 25 Connesso 1234567890 During the test you can listen and send DTMF tones but you can t talk to the users connected This function can be used for example to know the credit balance ofthe SIM CARD 4 Operation 4 1 Display Information GSM dialler use is facilitated by the presence of the display that provides information about the activities and status of the dialer The backlight of the display is handled automatically illuminates when the user types any button or activa
18. isplayed CODICE MASTER Enter your desired code of 4 digits Once you have typed the new code the TDX16 automatically returns the menu Select Code SELEZ CODICE CODICE COMANDI CODICE COMANDI 3 4 Customizable common vocal message 5 6 7 8 4 Use the buttons or directly by pressing the key to display 25 ABCD 4 Msg Comune Msg Comune Play Rec Holding down the button G will be possible to record a message Releasing it will stop recording NOTE Recording will stop automatically once it reaches the maximum message duration 15 seconds To play the recorded message press the key During playback or recording an animation will appear in the second line ofthe display as follows Msg Comune gt gt gt gt Msg Comune gt gt gt gt gt gt gt gt Toreturn to the previous menu press Esc The message is played atthe beginning of each call before requesting the code is TDX16 user s manual 3 5 Reset default settings 5 6 7 8 5 Clears all the phone numbers the address book you restore the factory settings of the dialer Once you enter the menu press 5 is visualized 25 ABCD 5 Ripristino IMP press the button 3 is displayed Conf Ripristino 7 SI 9 NO confirm with the button 7 is visualized for a few seconds R
19. l combinatore e premendo il pulsante P1 per circa 15 secondi Una volta entrati si visualizza Indica l intensit del 25 XABCD segnale 1 min 31max i Bubri ABCD Gestore Telefonico Rubrica 1 Rubrica 16 Numeri telefonici 2 Parametri Configurazione del modo di funzionamento del Rel OUT1 A Stato SerieTM PROTEC o A Impulsi SerieXM TM600P XR500 Configurazione riconoscimento Assenza Rete su IN K2 3 Codici Modifica del Codice MASTER e del Codice COMANDI 4 Messaggio Comune Possibilit di registrare un messaggio comune 5 Ripristino Azzera i codici MASTER e COMAND e tutta la rubrica telefonica 6 Info Visualizzazione del Modello Firmware e IMEI del modulo GSM 7 Riavvio Riavvia il combinatore 8 Test Effettua una chiamata di prova 3 1 Rubrica 5X6X7X8X1X1 3 1 1 Inserimento Numeri Telefonici Una volta entrati nel menu premere 1 si visualizza RUBRICA Inserisci Numeri premere si visualizza Numero 01 w Non Programmato premere WAD si visualizza Numero 01 gt a questo punto bisogna inserire il numero di telefono max di 32 cifre Numero 01 123456789 gt una volta inserito per confermare basta premere solo il ed immediatamente si visualizza Invio SMS all 7 SI 9 NO per associare l SMS al numero basta confermare premendo il tasto 7 SI oppure il 9 NO 6 Programmaz
20. l messaggio verr riprodotto all inizio di ogni telefonata prima della richiesta dell inserimento del codice TDX16 manuale dell utente 3 5 Ripristino impostazioni di fabbrica 5 6 7 8 5 cancellano tutti i numeri telefonici presenti nella rubrica si ripristinano le impostazioni di fabbrica del combinatore Una volta entrati nel men premere il tasto 5 si visualizza 25 ABCD 5 Ripristino IMP premendo il tasto si visualizza Conf Ripristino 7 SI 9 NO confermarmando con il tasto si visualizza per qualche istante Ripristino OK invece premendo il tasto 9 si esce dal men senza eseguire il reset 3 6 Informazioni sul TDX16 5X6X7X98 X1 X6 Per procedere basta utilizzare i tasti w 4 esi visualizza Modello TDX16 Y Rel Firmware IMEI p 738ESW 2 00 00 0000000000000000 3 7 Riavvio combinatore 56 71 8X X 3 Questa funzione riavvia il combinatore pu risultare utile a forzare una nuova registrazione della scheda SIM sulla rete GSM Una volta entrati nel men premere il tasto 7 si visualizza Indica l intensit del 25 XABCD segnale 1 min 31max ABCD Gestore Telefonico 7 Reset 3 8 Test 5X6X7X8YX X 8 Una volta entrati nel men premere il tasto Si visualizza Inserire Numero 10 HILTON Inserire un numero telefonico qualsiasi dopodich preme
21. me su 12V To switch from one configuration to another press the keys WD With alarm on OV suitable for installations with Central TM series PROTEC the timer begins counting when it fails on input voltage IN K2 While with alarm on 12V suitable for systems with XM Series plants the countdown begins when there is a voltage on input IN K2 To finish the configuration press the key ESC 3 2 3 Enable disable SMS forwarding function With this feature enabled the dialer sends all text messages received the number entered at number 1 in the address book Inoltro SMS Abilitato Press Cw for visualize Or Inoltro SMS Disabilitato for change configuration press the buttons WAD 3 3 MASTER and COMMANDS code In this menu you can change the MASTER Code and commands Once you enter the menu press E you are viewing 3 3 1 MASTER code 506078 03 The MASTER code allows you to access the menu functions which in addition to program the TDX16 also allows you to make any changes In fact to change the codes just confirm with a and visualize SELEZ CODICE CODICE MASTER now insert your desired code of 4 digits in automatically displays in the menu Select Code HilTron Programmation 3 3 2 COMMANDS code This code provides only one function and that is to INSERT or REMOVE the antitheft alarm connected to it For code commands use until you d
22. nd it resets the return thereof At the end of the count the alarm cycle Pause between one telephone call and the next Activation of the control from remote during the connection 11 TDX16 user s manual 4 2 Generaldescription of operation The TDX16 generates a series of calls to the phone numbers entered in the address book by sending as well as pre recorded message also the pre set SMS provided that the latter has been activated along with the phone number The first step is to insert the SIM Card as shown above You are viewing Inserire SIM Rubrica Off Turn OFF the dialer before inserting the SIM CARD then turn it back on Insert the SIM CARD the dialer registers the same Rubrica Off Once this operation is terminated is displayed 25 ABCD Rubrica Off Attention For a good functioning of the dialer the antenna must be connected The RED led GSM on panel indicates the activity of the GSM module OFF GSM not operative A flash every second Network not found A flash every 3 seconds Network found The green LED Status indicates the status of the TDX16 Long Flash followed by a short break GSM module in registration Slow blinking Combiner waiting Two short flashes pause In GSM connection during alarm cycles Rapid flashing Remote Control 12 HilTron Operation 4 3 COMMANDS code 1X2X3X4 The COMM
23. one telefonica GSM Il combinatore attende l inserimento di una SIM card staccare l alimentazione prima di inserire la SIM Tentativo di registrazione sulla rete telefonica in atto Indica l avvenuta connessione con il gestore telefonico specificato e segnala in particolare l intensit del segnale da 1 a 31 con il simbolo Y lampeggiante In corso un tentativo di chiamata telefonica Il tentativo di chiamata non ha avuto risposta Il num chiamato occupato ha rifiutato la chiamata La chiamata telefonica conclusa Connessione telefonica effettuata Ricezione chiamata telefonica Nessun numero telefonico inserito nella rubrica Sull ingresso Input INT1 non presente la tensione di 12V Sull ingresso Input INT1 presente la tensione di 12V Manca tensione di rete elettrica Tensione di rete elettrica presente Countdown di 600sec 10min che si attiva al mancare della rete elettrica e si resetta al ritorno della stessa Al termine del conteggio parte il ciclo di allarme Piccola pausa tra una telefonata e l altra Attivazione controllo da remoto durante la connessione 11 TDX16 Manuale dell utente 4 22 Descrizione generale del funzionamento L attivazione del TDX16 genera un ciclo di chiamate verso i numeri telefonici inseriti nella rubrica inviando oltre che il messaggio pre registrato anche l SMS pre impostato sempre che quest ultimo sia stato attivato assieme al numero telefonico La prima
24. operazione quella di inserire la SIM Card come mostrato in precedenza Si visualizza Inserire SIM Rubrica Off Spegnere il combinatore prima di inserire la SIM CARD poi riaccenderlo Inserita la SIM il combinatore effettua la registrazione della stessa Rubrica Off Una volta terminata questa operazione viene visualizzato 25 ABCD Rubrica Off IMPORTANTE Per un corretto funzionamento del combinatore l antenna deve sempre essere collegata Il LED rosso GSM presente sul pannello indica l attivit del modulo GSM Spento GSM non operativo Un flash ogni secondo Rete non trovata Un flash ogni 3 secondi Rete trovata Il LED verde Status indica lo stato del TDX16 Lampeggio lungo seguito da una pausa breve Modulo GSM in registrazione Lampeggio lento Combinatore in attesa Due lampeggi brevi una pausa In connessione GSM durante i cicli di allarme Lampeggio veloce Controllo Remoto 12 HilTron Funzionamento 4 3 Codice COMANDI 1X2X3X4 Il Codice COMANDI di default 2 X 3 4 a differenza del Codice MASTER permette di INSERIRE o DISINSERIRE l impianto antifurto collegato o di cambiare il CODICE COMANDI 4 3 1 Inserimento Disinserimento 1X2X3X4 X 8X1 Una volta digitato il Codice COMANDI premere in sequenza i tasti e 1 si visualizza Imp DISINSERITO 7 INS 9 DIS premendo sul tasto 7 il combin
25. pu essere montato su una comune cassetta murale tipo 503 Per la protezione antistrappo fissare anche la vite in dotazione IMPORTANTE Eliminare il codice PIN dalla SIM con un qualsiasi cellulare Inserire la SIM all interno del combinatore come indicato nella figura avendo cura di staccare prima l alimentazione HILTCOn Installazione 2 2 Schemadicollegamenti Serie XM centrale 060000000100 Serie 12 int sa 518 IN onp AUX 010 009 011 012 1 009 1 tt 1 u V e O INT IN IN OUT 1 TAMPER TDX16 ATTENZIONE Programmazione da effettuare sulla consolle dell impianto XM Per comunicare dalla centrale XM al TDX16 lo stato della rete bisogna abilitare un uscita per esempio l uscita logica 012 e digitare sulla consolle XM Codice MASTER si visualizza 000000000000 3StatoRete premere o 3 Stato Rete gt 000 000 000 000 inserire l uscita 012 012000000000 3 Stato Rete confermare con o uscire dalla programmazione premendo pi volte il tasto TDX16 manuale dell utente HILTrFON 3 Programmazione 5X6X7X8 La programmazione del combinatore consentita soltanto dalla tastiera locale digitando il codice MASTER di default 5 X 6 7 X 8 seguito da oppure aprendo i
26. questo punto inserire un codice desiderato di 4 cifre in automatico si riporta nel men Selezione Codice Programmazione 3 3 2 Codice COMANDI Questo codice invece permette di effettuare solo una funzione e cio quella di INSERIRE DISINSERIRE l impianto d antifurto ad esso collegato Per il codice comandi utilizzare fino a visualizzare CODICE MASTER inserire il codice desiderato di 4 cifre come visto in precedenza Una volta digitato il nuovo codice il TDX16 in automatico si riporta nel men Selezione Codice SELEZ CODICE CODICE COMANDI gt CODICE COMANDI 3 4 Messaggio Vocale Comune personalizzabile C5X 6X 7X 8 X4 Utilizzare i pulsanti o Oppure premendo direttamente il tasto C4 si visualizza 25 ABCD 4 Msg Comune Msg Comune 1 Rec Tenendo premuto il tasto sar possibile registrare un messaggio Rilasciandolo si interrompera la registrazione NOTA la registrazione si interrompera automaticamente una volta raggiunta la durata massima del messaggio 15 secondi Perriprodurre il messaggio registrato premere il tasto Durante la riproduzione la registrazione comparir un animazione nella seconda riga del display come Segue Msg Comune gt gt gt gt Msg Comune gt gt gt gt gt gt gt gt Per tornare al menu precedente premere il tasto so I
27. re il tasto l si visualizza 25 Chiama Indica l intensit dl segnale da1a31 1234567890 Funzionamento Numero telefonico rispondendo alla chiamata si visualizza 25 Connesso 1234567890 Durante il test possibile ascoltare ed inviare toni DTMF ma non possibile parlare con l utenza connessa Questa funzione pu essere utilizzata ad esempio per conoscere il credito residuo della SIM CARD 4 Funzionamento 4 1 Informazioni sul display L uso del combinatore GSM facilitato dalla presenza del display che fornisce informazioni sulle attivit e sullo stato del combinatore La retroilluminazione del display gestita automaticamente si accende quando l utente digita un qualsiasi tasto o si attiva un canale e si spegne trascorsi 20 secondi circa dal termine di tutte le operazioni Le informazioni sono visualizzate su due righe sulla prima appaiono quelle relative alle operazioni del combinatore sulla linea telefonica mentre sulla seconda le indicazioni riguardano lo stato dei canali Prima riga del display Init GSM INSERIRE SIM REGISTRAZIONE 20 ABCD 20 Chiama 20 Ch fallita Occupato 20 Fine chiam 20 Connesso Ric Chiamata Seconda riga del display Rubrica off Imp Disinserito Imp Inserito Assenza Rete Rete OK TIMER RETE 0600 Intervallo Gestione Remota Inizializzazione del modulo di connessi
28. stening Press 7 per enable or Press 9 for disable if the system is ON Press 0 for STOP CICLI NOTE To stop listening you can type With the command lt 0 gt stops the cycle of calls and closes the current phone call At the end of the call the display show 25 Fine Chiam Imp INSERITO 15 TDX16 user s manual 46 SMSsending Quando parte un ciclo di allarme vengono inviati per prima cosa gli SMS verso tutti i numeri abilitati a tale servizio nella rubrica messaggi sono a seconda dei casi alarm system network OK alarm system absence network System ON absence network System OFF absence network Bom NOTE The SMS is sent before making the call and the call are 3 attempts for each phone number 4 7 SMS residual credit and sending SMS received For know the remaining credit on the SIM inserted in TDX16 follow the steps below Send an SMS to your mobile phone with controller the following wording SMS XXXXXX YYYYYYY Telephone number of the SMS Text Service Center operator SIM Examples of some italian numbers service centers operators OPERATOR SMS TEXT TIM SMS 40916 PRECRESIN VODAFONE SMS 404 TRAFFICO WIND SMS 4155 Credit balence The dialer will send an SMS with the text that you entered previously vyy YY Y Y the Central phone number phone operator services XXXXXX The dialler will wait for a
29. ting a channel and turns off after 20 seconds from the end of all operations The information shall be displayed on two lines the first are those relating to the operations of the mode dial on the telephone line while the second relates to indications of state channels First line of the display Second line of the display Init GSM INSERT SIM REGISTRATION 20Y ABCD 20Y Call 20 Failed call Occupied 20 And of call 20 Connected Called Rec Chn Rubric off Chn Disabled Chn Enable Absence Network Rete OK Chn Timer 0600 Chn Interval Remote Control Initialization of the module of telephone logon GSM The combiner attends the insertion of one SIM card disconnect the power before inserting the SIM CARD Attempt of recording on the telephone net in course It indicates the happened logon with the specified telephone manager and marks it in particular the intensity of marks them from 1 to 31 with the symbol blinking In course an attempt of telephone call The call attempt has not had answer The called number turns out occupied or the call has been refused The telephone call is concluded Connection out telephone logon Called reception telephone No telephone number is associated to the channel On Input INT1 not present the voltage of 12V On Input INT1 is present the voltage of 12V No power supply Present voltage Countdown of 600sec 10 min that activates the mains fails a
30. w 25 Connesso gt gt gt 1234567890 You listen alarm system and or absence network depending the event enter code if correctly inserted only CODE commands switch to next step REMOTE MANAGEMENT which will be described below 25X Connesso GESTIONE REMOTA otherwise if it is incorrect after about 30 sec the call ends The alarm cycle continues with the next number in the address book In each cycle the mode dial makes 3 attempts to reach the user entered in the address book and then ends the cycle 14 HILTCOn Operation 4 5 Remote Control The remote control allows you to interrogate or controlled through the TDX16 the alarm system connected to it Is it possible to activate this mode both during an alarm call as described above is by directly calling the mode dial from a mobile phone can send DTMF tones When the connection is active on the display appear 25 Connesso Imp INSERITO listening to the pre recorded message Insert code only COMMANDS code if entered correctly you enable remote management otherwise if it is broken after about 30 sec the call ends Entered the code the display will appear 25 Connesso GESTIONE REMOTA You will hear the message System enabled or System disabled depending on the state of incorporation of the connected Network OK or Absence network Press 5 for ambiental li
Download Pdf Manuals
Related Search
Related Contents
Mobile Messenger Quick Start Manual Utilizar dispositivos 1394 (somente em alguns modelos) RP-1000 Quick Start Manual for DeskCNC Chamberlain HD150DM User's Manual Manuel d`installation HD BOX MEMORY Pentax Optio S5z Digital Camera manual de usuario Bedienungsanleitung . Mode d'emploi - prof GORDIUS Little Giant Copyright © All rights reserved.