Home
Installers Guide Guide d`installation
Contents
1. ON OFF ROCKER SWITCH INTERRUPTEUR BASCULE MARCHE ARRET O PS TH N I TP RS Ve So WHITE T2 GAS VALVE VALVE DE COMMANDE DE GAZ i wr BLANC T2 RED T ROUGE T1 THERMOPILE o o OPTIONAL WALL SWITCH THERMOSTAT OR REMOTE INTERRUPTEUR MURAL THERMOSTAT OU COMMANDE DISTANCE FACULTATIFS Figure 8 Standing Pilot Ignition Wiring Diagram 20 Figure 8 Sch ma de filage de l allumage par veilleuse Installing the Insert continued Installation de la cassette suite WARNING DO NOT CONNECT 110 120 VAC TO N AVERTISSEMENT NE BRANCHEZ PAS DE THE WALL SWITCH OR THE CONTROL VALVE COURANT DE 110 120 VCA A L INTERRUP WILL BE DESTROYED TEUR MURAL DE COMMANDE CELA DETRUIRAIT LA VALVE DE COMMANDE CAUTION LABEL ALL WIRES PRIOR TO DISCONNEC gm TION WHEN SERVICING CONTROLS WIRING ERRORS ELE a MCHED Pol 2 CEDE DES prm CAN CAUSE IMPROPER AND DANGEROUS OPERA MANDES LES ERREURS DE FILAGE RISQUENT TION VERIFY PROPER OPERATION AFTER SERVICING D ENTRA NER UN FONCTIONNEMENT ANO raed DA
2. Step3 The Gas Control Systems Step4 The Gas Supply Line Step5 Gas Pressure Requirements Step6 Wiring the Fireplace Step 7 Installing Logs and Ember Material Positioning the Logs Placing the Ember Material Step8 Installing the Trim Surrounds Step9 Before Lighting the Appliance Step10 Lighting the Appliance After the Installation Section 4 Maintaining and Servicing Your Appliance Contains updated information Table des mati res Consignes de s curit et mises en garde 2 Liste des pi ces de rechange 4 Section 1 Homologations et codes 7 Homologations et codes 7 Homologation de l appareil 7 Codes d installation a 7 Installation haute altitude sssesss 8 Section 2 Comment d buter 9 Pr sentation des appareils gaz Heat N Glo 9 Pr paration avant l installation 9 Evacuation et installation 10 Section 3
3. AVERTISSEMENT UN COURANT LEC TRIQUE DE 110 120 VCA NE DOIT JAMAIS TRE BRANCH UN SYSTEME DE VALVE DE COMMANDE MILLIVOLT STANDING PILOT VEILLEUSE SN EE S SY 3 8 10 mm Figure 6 Gas Controls Systems Sow Figure 6 Syst mes de commande de gaz Installing the Insert continued Step 4 The Gas Supply Line NOTE Have the gas supply line installed in accordance with local building codes by a qualified installer approved and or licensed as required by the locality NOTE Before the first firing of the fireplace the gas supply line should be purged of any trapped air NOTE Consult local building codes to properly size the gas supply line leading to the 1 2 inch 13 mm hook up at the unit This gas fireplace is designed to accept a 1 2 inch 13 mm gas supply line To install the gas supply line Alisted and State of Massachusetts approved 1 2 inch 13mm tee handle manual shut off valve and a listed flexible gas connector are connected to the 1 2 inch 13mm inlet of the control valve NOTE If substituting for these components please consult local codes for compliance The gas line may be run from either side of the fireplace provided the hole in the outer wrap does not exceed 2 in diameter and it does not penetrate the airtight firebox The gap between the supply piping and gas access hole can be plugged with non comb
4. N entreposez ou n utilisez jamais d essence ou autres vapeurs et liquides inflammables proximit de cet appareil ou de tout autre appareil QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ Ne tentez d allumer aucun appareil Ne touchez aucun interrupteur lectrique N utilisez aucun t l phone dans votre difice Appelez imm diatement votre fournisseur de gaz vous servant du t l phone d un voisin Suivez les ins tructions du fournisseur de gaz Si vous ne pouvez pas atteindre votre fournisseur de gaz appelez le service des incendies L installation et l entretien doivent tre effectu s par un installateur qualifi une agence de maintenance ou le four nisseur de gaz 1 Cetappareil peut tre install dans un mobile home pr fabriqu qui a t vendu et ne sera plus d plac si les codes locaux l autorisent 2 Cet appareil est concu pour tre utilis seulement avec le type de gaz indiqu sur la plaque signal tique Cet appareil ne peut tre converti l utilisation d autres gaz qu avec un module homologu 438 910EFB 12 00 WARNING Improper installation ad justment alteration service or mainte nance can cause injury or property damage Refer to this manual For assistance or additional informa tion consulta qualified installer service agency or the gas supplier Read this manual before installing or operating this appliance This Installers Guide
5. 7 8 m or less length of 18 A W G minimum wire and connect it to the fireplace valve pigtails Installation de la cassette suite tape 6 Filage lectrique du foyer REMARQUE Le filage lectrique doit tre effectu par un lectricien agr ATTENTION D BRANCHEZ LES COMMANDES DIS TANCE SI VOUS VOUS ABSENTEZ POUR DES PERI ODES PROLONGEES DE CETTE FACON LE FOYER NE POURRA PAS S ALLUMER ACCIDENTELLEMENT Filage de l allumage par veilleuse Sp cifications de l appareil Le fonctionnement de cet appareil NE n cessite PAS de courant lectrique de 110 120 VCA AVERTISSEMENT NE BRANCHEZ PAS DE COURANT ELECTRIQUE DE 110 120 VCAA LA VALVE DE COMMANDE DE GAZ CELA ENTRAINERAIT UN MAUVAIS FONCTIONNEMENT DE L APPAREIL ET LADESTRUCTION DE LAVALVE Accessoires facultatifs Les ensembles facultatifs de ventilateur et de commande distance n cessitent que la boite de d rivation install e en usine soit aliment e par un courant lectrique de 110 120 VCA Faites sortir le cordon par l encoche de l entourage et branchez le dans une prise ad quate Interrupteur mural de commande Placez l interrupteur mural de commande l emplacement voulu sur un mur D ployez un fil de calibre 18 AWG minimum ne d passant pas 7 8 m de long et branchez le aux raccords flexibles de la valve du foyer THERMOCOUPLE 3 16 PIGGY BACK CONNECTOR CONNECTEUR EN CASCADE DE 3 16 PO x
6. Installation de la cassette 12 tape 1 Installation du syst me d vacuation 12 Homologation du syst me d vacuation 12 tape 2 Emplacement nivellement et solidification de la cassette 17 tape 3 Syst mes de commande de gaz 17 tape 4 Conduit gaz aaa aaa aaa 18 tape 5 Sp cifications de la pression du gaz 19 tape 6 Filage lectrique du foyer 20 tape 7 Installation des b ches et des braises 22 Mise en place des b ches 22 Mise en place des braises 22 tape 8 Installation des entourages 24 Etape 9 Avantd allumerl appareil 26 tape 10 Allumage de l appareil 26 Apr s l installation 26 Section 4 Entretien et service de votre appareil 27 Contient des informations mises jour Service Parts HEAT N CLO No one builds a better fire AT SUPREME C NG LP Exploded Parts Diagram AT SUPREME C GN PL Vue clat e des pi ces Part number list on following page La liste des num ros de pi ce se trouve la page suivante AT SUPREME C NG LP Service Parts List AT SUPREME C GN PL Liste des pi c
7. National Fuel Gas Code ANSI Z223 1 in the United States or the CAN CGA B149 Installation Codes in Canada The appliance must be electrically grounded in accordance with local codes or in the absence of local codes with the National Electric Code ANSI NFPA No 70 in the United States or to the CSA C22 1 Canadian Electric Code in Canada These models may be installed in a bedroom or bed sitting room in the U S A and Canada Homologations et codes Homologation de l appareil Les mod les Heat N Glo dont il est question dans ce Guide d installation ont t test s conform ment aux normes d homologation et ont t approuv s par les laboratoires comp tents NORME D HOMOLOGATION MODELE AT Supreme C LABORATOIRE Underwriters Laboratories TYPE Cassette de chemin e gaz syst me d vacuation directe ANSI Z21 88 CSA2 33 UL307B NORMES Codes d installation L installation de l appareil doit tre conforme aux codes locaux Avant d installer l appareil consultez les autorit s locales en mati re de codes de construction afin de vous assurer que vous respectez tous les codes en vigueur y compris les permis de construire et les inspections En l absence de codes locaux l installation de l appareil doit tre conforme au code am ricain National Fuel Gas Code ANSI Z223 1 aux Etats Unis ou aux Codes des installations CAN CGA B149 au Canada L appareil doit tre muni d un fil de terre conform ment aux c
8. Si ces instructions ne sont pas suivies la garantie sera annul e et vous pourriez causer un incendie La garantie Heat N Glo division de Hearth Technologies Inc sera annul e par les actes suivants pour lesquels Heat N Glo d cline toute responsabilit Installation d l ments endommag s dans l appareil ou dans le syst me d vacuation Modification de l appareil ou du syst me d vacuation directe Installation diff rente de celle indiqu e par Heat N Glo Placement incorrect des b ches gaz ou de la porte en verre Installation et ou utilisation de pi ces n ayant pas t fabriqu es et approuv es par Heat N Glo m me si cette pi ce ou cet accessoire a t homologu par un laboratoire d essais ind pendant ou un autre organisme comp tent CES ACTES POURRAIENT CAUSER UN INCENDIE REMARQUE La grille a t fix e sur le haut du foyer pour le transport Retirez la grille en d vissant les supports avant de commencer l installation Getti ng Started continued Comment d buter suite VENTING AND INSTALLATION 1 Heat N Glo gas inserts are designed for recessed instal lations into solid fuel Masonry or Factory Built Non Com bustible fireplaces that have been installed in accordance with the National Provincial State and local building codes Minimum fireplace opening requirements are shown in Figure 1 ofthis installation manual The firebrick refrac tory can be remove
9. assembly MUST be in place on the fireplace before the unit can be placed into safe operation DO NOT OPERATE this appliance with the glass door removed cracked or broken Replacement of the glass door should be performed by a licensed or qualified service person DO NOT strike or slam the glass door The glass door assembly SHALL ONLY be replaced as a complete unit as supplied by the gas fireplace manufacturer NO SUBSTITUTE material may be used DO NOT USE abrasive cleaners on the glass door assembly DO NOT ATTEMPT to clean the glass door when it is hot Turn off the gas before servicing this appliance It is recommended that a qualified service technician perform an appliance check up at the beginning of each heating season Any safety screen or guard removed for servicing must be replaced before operating this appliance A A A A A N OBSTRUEZ JAMAIS la circulation d air de combustion et de ventilation Maintenez l avant de l appareil DEGAGE de tout obstacle et mat riau afin d en permettre le service et le bon fonctionnement En raison de la temp rature lev e l appareil doit SE TROUVER en dehors des zones de passage et bonne distance des meubles et des rideaux NE PLACEZ JAMAIS DE v tements OU mat riaux inflammables sur l appareil ou proximit Les enfants et les adultes doivent tre AVERTIS des risques que pr sentent les surfaces haute temp rature et doivent RESTER A L ECART afin d vit
10. d air de combus tion de 76 mm de long un 1 raccord conduit capuchon et un 1 capuchon vertical SLK 991DA ou SLK 980D REMARQUE II sera peut tre n cessaire de d monter le registre de la chemin e en magonnerie pour permettre l installation du conduit flexible Cette chemin e a t modifi e pour pouvoir recevoir une cassette et doit tre inspect e par une personne qualifi e avant d tre r utilis e en tant que chemin traditionnelle REMARQUE L tiquette ci dessus qui se trouve dans le paquet d instructions doit tre appos e sur la chemin e existante avant l installation du mod le AT SUPREME C Sur les chemin es bois pr fabriqu es sans d gagement l utilisation du module LINK ZC ADP au lieu du solin carr standard vous permettra de monter le raccord et le capuchon sur un conduit m tallique Par ailleurs l utilisation du module FLASH DAMP bouchera herm tiquement l ouverture du registre si le conduit d admission d air d bouche juste au dessus du registre Ces deux modules sont recommand s sur les chemin es bois pr fabriqu es sans d gagement Raccord du conduit d air Faites passer les conduits flexibles de 76 mm dans la chemin e Retirez le support de collet de raccord du dessus de l appareil Consultez la Figure 5 Fixez l extr mit inf rieure des conduits flexibles au support de collet de raccord l aide de 3 vis t le sur chaque collet Ins rez la cassette et renfoncez toute lon
11. on insert A VACUATION ET INSTALLATION 1 Les cassettes gaz Heat N Glo sont con ues pour tre encastr es dans des chemin es en mat riaux non com bustibles en ma onnerie ou pr fabriqu es combus tible solide qui ont t install es conform ment aux codes de construction nationaux provinciaux et locaux Les sp cifications d ouverture minimum de la chemin e sont indiqu es sur la Figure 1 de ce manuel d installation Les briques r fractaires peuvent tre retir es d une chemin e pr fabriqu e afin d obtenir l ouverture minimum sp cifi e pour la cassette gaz Afin d obtenir des performances une s curit et une efficacit optimales les cassettes doivent tre install es avec un rev tement de conduit approuv conform ment aux codes CAN CGA B 149 ou au code am ricain Na tional Fuel Code ANSI Z223 et ces instructions AVERTISSEMENT LACHEMIN E COMBUS TIBLE SOLIDE A T CONVERTIE POUR TRE UTLIS E SEULEMENT AVEC DU GAZ ET NE PEUT PLUS TRE UTILIS E POUR BR LER DU BOIS OU D AUTRES COMBUSTIBLES SOLIDES MOINS QUE TOUTES LES PIECES D ORIGINE NE SOIENT REMISES EN PLACE ET QUE LA CHEMIN E N AIT T NOUVEAU APPROUV E PAR LES AUTORIT S COMP TENTES Leregistre du tuyau de la chemin e combustible solide doit tre verrouill en position d ouverture maximale ou bien d mont pour l installation La chemin e doit tre nettoy e en bon tat de fon
12. the surround against the face of the unit aligning the holes in upper and lower right and left corners and 5 Faites glisser l entourage contre la facade de l appareil secure the surround to the unit with the attachment en alignant les orifices des coins sup rieurs et inf rieurs screws droits et gauches et fixez l entourage sur l appareil l aide des vis de fixation NOTE PLACE THE THREE INSULATION PIECES INTO THE CAVITIES AT THE BACK OF THE SURROUND REMARQUE PLACEZ LES TROIS MORCEAUX BEFORE POSITIONING THE INSERT INTO THE FACTORY D ISOLANT DANS LES CAVIT S L ARRI RE DE BUILT OR MASONRY FIREPLACE THIS INSULATION L ENTOURAGE AVANT DE PLACER LA CASSETTE DANS WILL HELP SEAL FOR COLD AIR LEAKS LA CHEMIN E PR FABRIQU E OU EN MACONNERIE CET ISOLANT EMP CHE LE PASSAGE D AIR FROID I 12 30 5cm MAX MANTEL HABILLAGE L 12 30 5cm MIN TOP OF UNIT DESSUS DE L APPAREIL n Figure 13 Figure 13 Figure 13 shows the minimum vertical and corresponding La Figure 13 repr sente la dimension minimale verticale et maximum horizontal dimensions of mantels or other la dimension maximale horizontale correspondante des combustible projections above the gas fireplace habillages ou autres saillies combustibles au dessus du foyer gaz 25 Installing the Inser
13. verre 1 Place the ember material onto the top of the burner front ports only Also place dime size pieces over the 4 front burner screws 1 Placez les braises sur le br leur seulement sur les orifices avant Placez gale ment des braises de la taille d une pi ce de 10 cents sur les 4 vis avant du br leur MATERIAL BRAISES SCREWS VIS Figure 11 Figure 11 Placement of the Mise en place des Ember Material braises 23 Installing the Insert continued Installation de la cassette suite Step 8 Installing the Trim Surrounds Combustible materials MUST NEVER overlap onto the front tape 8 Installation des entourages Les mat riaux combustibles NE DOIVENT JAMAIS face chevaucher la facade WARNING WHEN FINISHING THE FIREPLACE AVERTISSEMENT LORS DE LA FINITION DE INSERT NEVER OBSTRUCT OR MODIFY THE LACASSETTE DE CHEMIN E N OBSTRUEZ ET AIR INLET OUTLET GRILLES ON THE INSERT NE MODIFIEZ JAMAIS LES GRILLES IN ANY MANNER D ADMISSION DE SORTIE D AIR DE LA CASSETTE D AUCUNE FACON QUE CE SOIT FIREBOX SURROUND WITH TRIM FOYER ENTOURAGE GARNITURE SURROUND ENTOURAGE ON OFF SWITCH INTERRUPTEUR uU MARCHE ARR T TRIM DOOR FILS DE BASSE TENSION Figure 12 Figure 12 NOTE REMOVE FRONT TRIM DOOR AND GLASS DOOR ASSEMBLIES FROM THE INSERT BEFORE SURROUND INSTALLATION 1 Find the coiled low voltage wires and ON OFF switch a
14. 07 5 613 487 Australie 543790 586383 Canada 1 123 296 1 297 746 2 195 264 Mexique 97 0457 Nouvelle Z lande 200265 et autres bre vets am ricains et trangers en instance Please contact your Heat N Glo dealer with any ques tions or concerns For the number of your nearest Heat N Glo dealer please call 952 985 6000 Heat N Glo a division of Hearth Technologies Inc 20802 Kensington Boulevard Lakeville MN 55044 Printed in U S A Copyright 2000 This product is covered by one or more of the following patents United States 4 112 913 4 408 594 4 422 426 4 424 792 4 520 791 4 793 322 4 852 548 4 875 464 5 000 162 5 016 609 5 076 254 5 191 877 5 218 953 5 328 356 5 429 495 5 452 708 5 542 407 5 613 487 Australia 543790 586383 Canada 1 123 296 1 297 746 2 195 264 Mexico 97 0457 New Zealand 200265 or other U S and 28
15. 1 12 12 12 De 12 12 14 12 De 14 12 16 12 De 16 12 18 12 De 18 12 20 12 De 20 12 21 12 H MINI EN CM Figure 2 Hauteur minimum entre le toit et l ouverture d vacuation la plus basse Installing the Insert continued TERMINATION CAP CAPUCHON ADAPTOR RACCORDJ EXHAUST VENT PIPE CONDUIT D VACUATION if PLACE INSULATION HERE AROUND DAMPER AREA PLACEZ L ISOLANT ICI AUTOUR DU REGISTRE V 14ft 4 2m Minimum 50ft 15m Maximum Installation de la cassette suite This option shows both exhaust and inlet air vent pipes attached to the adaptor Cette option repr sente les conduits d vacuation et d admission d air attach s au raccord WARNING DO NOT BLOCK PIPE END WITH INSULATION OR ANY OTHER SEALING MATERIAL AVERTISSEMENT NE BOUCHEZ PAS L EXTREMITE DU CONDUIT AVEC DE L ISOLANT OU UN AUTRE MAT RIAU DE FERMETURE Figure 3 WARNING THE EXHAUST PIPE MUST ONLY BE CONNECTED TO THE EXHAUST STARTING COLLAR OF THE UNIT AND THE CENTER COLLAR OF THE TERMINATION CAP THE INLET AIR PIPE
16. EUT tre raccord au capuchon ou aboutir l int rieur de la chemin e L ouverture inf rieure de la chemin e doit tre jointe herm tiquement aux conduits si le conduit d air de combustion n est PAS raccord au capuchon Voir Figures 3 4 et 5 REMARQUE La longueur verticale conduit d vacuation doit tre comprise entre 4 3 m tres et 15 2 m tres Cette dimension est mesur e entre les collets de raccord de l appareil et l extr mit de la derni re section de conduit d vacuation Voir la dimension V sur la Figure 3 Installing the Insert continuea Installation de la cassette suite A vertical vent termination system installed on this model will include one 1 length of 3 inch flexible vent pipe for the combustion air one 1 pipe to cap adaptor and one 1 SLK 991DA or SLK 980D vertical termination cap NOTE The damper of the masonry chimney may need to be removed to allow installation of the flexible vent pipe This fireplace has been altered to accommodate an insert and should be inspected by a qualified person prior to re use as a conventional fireplace NOTE The above label located in the instruction package must be affixed to the existing fireplace prior to installation of Model AT SUPREME C For zero clearance factory built woodburning fireplaces the use of kit LINK ZC ADP in place of the standard square flashing will allow you to mount the adaptor and cap on metal pipe Additionally the u
17. H EAT N CLO Installers Guide No one builds a better fire Guide d installation c UL Jus Model Mod le LISTED AT Supreme C Underwriters Laboratories Listed Homologu Underwriters Laboratories WARNING If the information in these instructions is not followed exactly a fire or explosion may result causing property damage personal injury or death Do not store or use gasoline or other flammable vapors and liquids in the vi cinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS e Donottry to light any appliance Do not touch any electrical switch Do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas sup plier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier This appliance may be installed in an after market permanently located manufactured mobile home where not prohibited by local codes 2 This appliance is only for use with the type of gas indicated on the rating plate This appli ance is not convertible for use with other gases unless a certified kit is used n M S SS AVERTISSEMENT Si ces instructions ne sont pas suivies a la lettre un incendie ou une explosion pourraient en r sulter causant des dommages mat riels des blessures ou la mort
18. MUST ONLY BE CONNECTED TO THE INLET AIR COLLAR OF THE UNIT AND EI THERATTACHED TO THE INLET AIR COLLAR OF THE TERMINATION CAP OR TERMINATED IN THE CHIMNEY INLET AIR VENT PIPE CONDUIT D ADMISSION D AIR aoe e Figure 3 AVERTISSEMENT LE CONDUIT D VACUA TION DOIT TRE RACCORD SEULEMENT AU COLLET DE RACCORD DU SYST ME D VACUATION DE L APPAREIL ET AU COLLET CENTRAL DU CAPUCHON LE CONDUIT D ADMISSION D AIR DOIT TRE RACCORD SEULEMENT AU COLLET CORRESPON DANT DE L APPAREIL ET SOIT TRE ATTACH AU COLLET CORRESPONDANT DU CAPUCHON SOIT D BOUCHER DANS LA CHEMIN E Installing the Insert continued Installation de la cassette suite EXHAUST COLLAR COLLET D VACUATION TERMINATION CAP CAPUCHON ADAPTOR RACCORD INLET AIR COLLAR COLLET D ADMISSION D AIR Figure 4 INLET AIR STARTING COLLAR COLLET DE RACCORD DU CONDUIT D ADMISSION D AIR EXHAUST STARTING COLLAR COLLET DE RACCORD DU CONDUIT D EVACUATION INLET AIR STARTING COLLAR COLLET DE RACCORD DU CONDUIT D ADMISSION D AIR EXHAUST STARTING COLLAR COLLET DE RACCORD DU CONDUIT D EVACUATION Figure 5 16 Installing the Insert continued Step 2 Positioning Leveling and Securing Insert 1 Place the insert into position 2 Level the insert fro
19. NGEREUX VERIFIEZ LE BON FONCTIONNEMENT DE L APPAREIL APRES CHAQUE SERVICE FAN WIRING DIAGRAM VARIABLE SPEED CONTROL SCH MA DE FILAGE DU VENTILATEUR COMMANDE DE VITESSE VARIABLE JUNCTION BOX BLACK T NOIR BOITE DE DERIVATION co BLACK NOIR BLOWER RECEPTACLE 17 DU VENTILATEUR BLACK M J NOIR KE 0 GROUND TERRE TEMPERATURE SENSOR SWITCH INTERRUPTEUR DE D TECTION THERMIQUE BLOWER VENTILATEUR 110 120 VAC 110 120 V CA TEMPERATURE SENSOR SWITCH JUNCTION BOX b INTERRUPTEUR DE BO TE DE DERIVATION lt a i DETECTION THERMIQUE NOTE IF ANY OF THE ORIGINAL WIRE AS SUP PLIED WITH THE APPLIANCE MUST BE RE PLACED IT MUST BE REPLACED WITH TYPE 105 C RATED WIRE REMARQUE S IL S AV RE N CESSAIRE DE REMPLACER LE FILAGE ORIGINAL TEL QUE FOURNI AVEC L APPAREIL UTILISEZ DU FILAGE DE TYPE 105 C VENTILATEUR SPEED CONTROL RHEOSTAT COMMANDE DE VITESSE RH OSTAT Figure 9 Fan Wiring Diagram Figure 9 Sch ma de filage du ventilateur 21 Installing the Insert continued Installation de la cassette suite Step 7 Installing Logs and Ember Material Positioning the Logs If the gas logs have been factory installed they should not need to b
20. T D VACUATION AU DESSUS DU TOIT CES HAUTEURS MINIMALES SONT N CESSAIRES POUR DES RAISONS DE S CURIT CONSULTEZ LE SCH MA SUIVANT POUR CONNA TRE LES HAUTEURS MINIMALES RESPECTER LORSQUE LE CAPUCHON EST LOIGN D AU MOINS 61 CM D UN MUR Note This also pertains to vertical vent systems installed VERTICAL ET AU DESSOUS D UN SURPLOMB on the outside of the building Remarque Ces restrictions s appliquent galement aux syst mes d vacuation verticale install s l ext rieur de l difice h HORIZONTAL OVERHANG SURPLOMB 2 FT 61cm MINI VERTICAL WALL qo gt MUR VERTICAL ye LOWEST DISCHARGE ls Se OPENING L OUVERTURE D VACUATION LA PLUS BASSE ee TERMINATION CAP CAPUCHON X 12 E ROOF PITCH IS X 12 LA PENTE DU TOIT EST DE X 12 H MINI MINIMUM HEIGHT FROM ROOF TO LOWEST DISCHARGE OPENING H MINI HAUTEUR MINIMUM ENTRE LE TOIT ET LOUVERTURE D VACUATION LA PLUS BASSE L ROOF PITCH H MIN FT Flat to 6 12 1 0 6 12 to 7 12 1 25 Over 7 12 to 8 12 1 5 Over 8 12 to 9 12 Over 9 12 to 10 12 Over 10 12 to 11 12 Over 11 12 to 12 12 Over 12 12 to 14 12 Over 14 12 to 16 12 Over 16 12 to 18 12 Over 18 12 to 20 12 Over 20 12 to 21 12 Figure 2 Minimum height from roof to lowest discharge opening PENTE DU TOIT De plat 6 12 De 6 12 7 12 De 7 12 8 12 De 8 12 9 12 De 9 12 10 12 De 10 12 11 12 De 1
21. U VENTILATEUR ACCES DU FILAGE ELECTRIQUE DIMENSIONS MINIMUM DE L APPAREIL LARGEUR AVANT 835 mm LARGEUR ARRI RE 521 mm PROFONDEUR 345 mm HAUTEUR 508 mm 32 7 8 835mm 20 12 521mm 13 5 8 345mm 20 508mm NOTE If exhaust collar on insert and fireplace damper do not line up add 4 inches 102mm to minimum fireplace height for bends in vent pipe 11 REMARQUE Si le collet d vacuation de la cassette et le registre de la chemin e ne s alignent pas ajoutez 102 mm a la hauteur minimale de la chemin e pour les coudes du conduit d vacuation Installing the Insert Step 1 Installing the Vent System Vent System Installation Precautions Before starting installation of vent kits the installer should read these instructions and the Vent Kit Instructions to ensure that a proper vent installation is completed Consult your local Building Codes before beginning the Installation WARNING THIS GAS INSERT AND VENT ASSEMBLY MUST BE VENTED DIRECTLY TO THE OUTSIDE AND MUST NEVER BE ATTACHED TO A CHIMNEY SERVING A SEPARATE SOLID FUEL BURNING APPLIANCE EACH GAS APPLIANCE MUST USEA SEPARATE VENT SYSTEM COMMON VENT SYSTEMS ARE PROHIBITED Vent System Approvals Table 1 and Figure 3 through 5 shows the vent termination caps and systems approved for use with these models Approved vent system terminations are labeled for identification 3 inch diameter listed flexible alu
22. agrams including the dimensions are shown in this section Pre installation Preparation This gas insert and its components are tested and safe when installed in accordance with this Installers Guide Report to your dealer any parts damaged in shipment particularly the condition of the glass Do not install any unit with damaged incomplete or substitute parts The vent system components and trim surrounds are shipped in separate packages The gas logs are packaged separately and must be field installed Read all of the instructions before starting the installation Follow these instructions carefully during the installation to ensure maximum safety and benefit Failure to follow these instructions will void the owner s warranty and may present a fire hazard The Heat N Glo a division of Hearth Technologies Inc Warranty will be voided by and Heat N Glo disclaims any responsibility for the following actions Installation of any damaged appliance or vent system component Modification of the appliance or direct vent system Installation other than as instructed by Heat N Glo Improper positioning of the gas logs or the glass door Installation and or use of any component part not manu factured and approved by Heat N Glo not withstanding any independent testing laboratory or other party approval of such component part or accessory ANY SUCH ACTION MAY POSSIBLY CAUSE A FIRE HAZ ARD NOTE The log grate has been se
23. ation AVERTISSEMENT CETTE CASSETTE GAZ ET CE SYSTEME D VACUATION DOIVENT VACUER LES GAZ DE COMBUSTION DIRECTEMENT L EXT RIEUR ET NE DOIVENT JAMAIS TRE RAC CORD S UNE CHEMIN E DESSERVANT UN AU TRE APPAREIL COMBUSTIBLE SOLIDE CHAQUE APPAREIL GAZ DOIT UTILISER UN SYST ME D VACUATION DISTINCT L UTILISATION DE SYST MES D VACUATION EN COMMUN EST INTERDITE Homologation du syst me d vacuation Le Tableau 1 etles Figures 3 5 repr sentent les capuchons et les syst mes d vacuation homologu s pour utilisation avec ces mod les Les terminaisons de syst me d vacuation homologu es portent une tiquette d identification Des conduits flexibles homologu s de 76 mm de diam tre en aluminium ou en acier inoxydable servent l aspiration de l air de combustion et l vacuation des gaz de combustion AUCUN AUTRE SYST ME OU L MENT D VACUATION NE PEUT TRE UTILIS Des instructions d installation d taill es sont incluses avec chaque module de terminaison de syst me d vacuation et doivent tre utilis es en conjonction avec ce manuel vacuation horizontale Le syst me d vacuation de ce mod le NE PEUT PAS comporter de terminaison horizontale vacuation verticale Les conduits DOIVENT tre raccord s aux collets corres pondants de l appareil ET le conduit d vacuation DOIT tre raccord au capuchon pour que l appareil puisse fonctionner Le conduit d air de combustion P
24. cassette suite Step 5 Gas Pressure Requirements Pressure Natural Gas Propane 11 0 inches W C 14 0 inches W C 10 0 inches W C 5 0 inches W C 14 0 inches W C Minimum Inlet Pressure Maximum Inlet Gas Pressure Manifold Pressure 3 5 inches W C A one eighth 1 8 inch 3 mm N P T plugged tapping is provided on the inlet and outlet side of the gas control for a test gauge connection to measure the manifold pressure Use a small flat blade screwdriver to crack open the screw in the center of the tap Position a rubber hose over the tap to obtain the pressure reading The fireplace and its individual shut off valve MUST be disconnected from the gas supply piping system during any pressure testing of the system at test pressures in excess of one half 1 2 psig 3 5 kPa The fireplace MUST be isolated from the gas supply piping system by closing its individual shut off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than one half 1 2 psig 3 5 kPa tape 5 Sp cifications de la pression du gaz Gaz naturel Pression minimale 127 mm d approvisionnement CE Pression maximale 356mm d approvisionnement CE Pression Propane Pression du collecteur Une d rivation de visite NPT de 3 mm est pr vue sur le c t d admission et sur le c t de sortie de la commande de gaz afin d y brancher un manom tre pour mesurer la pression du c
25. ctionnement et compos e de mat riaux non combus tibles V rifiez que toutes les portes de ramonage soient bien ajust es afin que l air ne puisse pas entrer dans la chemin e Installez la cassette sans l entourage et effectuez tous les raccords de gaz et d vacuation ainsi que tous les branchements lectriques AVERTISSEMENT Le d coupage de t les n est en aucun cas autoris pour faciliter l installation Si la chemin e pr fabriqu e ne comporte aucun orifice d arriv e de gaz un orifice d acc s de 25 mm de diam tre maximum peut tre perc au bas des parois lat rales ou au fond du foyer de mani re appropri e Installez l entourage d coratif Veuillez consulter les ins tructions incluses avec l entourage Une fois l entourage d coratif install sur la cassette v rifiez que ses conduits d air lat raux ne soient pas obstru s Getting Started continued When planning a fireplace insert installation it s necessary to determine The vent system configuration to be used Gas supply piping Whether optional accessories devices such as a wall switch or remote control are desired Figure 1 Diagram of the AT Supreme C 20 1 8 lt 511 1mm 4 1 2 114 8mm bE 10 255 6mm HA Comment d buter suite Avant de commencer l installation de la cassette de chemin e il est n cessaire de d terminer Laconfiguration du syst me d vacuation qui se
26. cured to the top of the firebox for shipment Remove the log grate by unscrewing the brackets before proceeding with your installation Pr sentation des appareils gaz Heat N Glo Les appareils gaz vacuation directe Heat N Glo sont con us pour aspirer tout l air de combustion de l ext rieur de l difice et expulser tous les gaz de combustion en dehors de l difice Les informations contenues dans ce Guide d installation sauf dans le cas de mention contraire s appliquent tous les mod les et tous les syst mes de commande de gaz Cette section comprend des sch mas de l appareil gaz avec ses dimensions Pr paration avant l installation Cette cassette gaz et ses l ments ont t test s et ne pr sentent aucun danger s ils sont install s conform ment ce Guide d installation Signalez votre concessionnaire toutes pi ces endommag es lors du transport en particulier s il s agit de la porte en verre N installez aucun appareil dont des pi ces sont endommag es sont incompl tes ou ont t remplac es par des pi ces diff rentes Les l ments du syst me d vacuation et les entourages sont exp di s dans diff rents colis Les b ches gaz sont emball es s par ment et doivent tre install es sur place Lisez toutes les instructions avant de commencer l installation Suivez attentivement ces instructions pendant l installation afin d assurer une s curit et une efficacit optimales
27. d from a factory built fireplace in order to gain minimum gas insert opening requirements Toassure top performance safety and efficiency inserts must be installed with an approved flue liner as per CAN CGA B 149 or National Fuel Code ANSI Z223 and these instructions WARNING THE SOLID FUEL FIREPLACE HAS BEEN CONVERTED FOR USE WITH GAS ONLY AND CANNOT BE USED FOR BURNING WOOD OR SOLID FUELS UNLESS ALL ORIGINAL PARTS HAVE BEEN REPLACED AND THE FIREPLACE HAS BEEN REAPPROVED BY THE AUTHORITY HAVING JURISDICTION The solid fuel fireplace s flue damper must be fully locked in the open position or removed for installation The chimney must be cleaned and in good working order and constructed of noncombustible materials Make sure that all chimney cleanouts fit properly so air cannot leak into the chimney Install the insert without the trim surround and make all gas venting and electrical connections WARNING Under no circumstances is cutting of sheet metal surfaces allowed for installa tion If the factory built fireplace has no gas access holes provided an access hole of 1 diameter 25mm or less may be drilled through the lower sides or bot tom of the combustion chamber in a proper work manship like manner Install decorative trim surround Please refer to instruc tions included with the trim surround Ensure there are no obstructions to side air passages of decorative trim once installed
28. e fabricant du foyer gaz AUCUN mat riau DE SUBSTITUTION ne peut tre utilis N UTILISEZ PAS de produits d entretien abrasifs sur la porte en verre N ESSAYEZ PAS de nettoyer la porte en verre lorsqu elle est chaude Fermez le gaz avant d effectuer le service de cet appareil Il est conseill qu un technicien de service qualifi inspecte l appareil au d but de chaque saison de chauffage Tous les crans et dispositifs de protection d mont s pour le service doivent tre remis en place avant l utilisation de cet appareil Table of Contents Safety and Warning Information Service Parts List Section 1 Approvals and Codes Approval Listing and Codes Appliance Certification code Installation CodeS irens asna High Altitude Installations Section 2 Getting Started Introducing the Heat N Glo Gas Appliances Pre installation Preparation Venting and Installation a Section 3 Installing the Insert Step 1 Installing the Vent System Vent System Approvals Step2 Positioning Leveling and Securing the Insert
29. e positioned If the logs have been packaged separately refer to the installation instructions that accompany the logs Save the log instructions with this manual If sooting occurs the logs might need to be repositioned slightly to avoid excessive flame impingement Placing the Ember Material Two separate bags of ember material are shipped with this gas appliance The bag labeled Golden Ember GE 93 is flame colorant material The bag labeled Glowing Ember 050 721 is standard glowing ember material To place the ember material Remove the trim door by lifting up and removing from the unit Unlatch the latches at the top and bottom of the glass door Remove the glass door from the unit Cover the top of the burner with a single layer of ember material Then sprinkle GE 93 on top of the burner Save the remaining ember materials for use during fire place servicing Replace the glass door Re install and latch the glass door Replace the trim door 22 Etape 7 Installation des b ches et des braises Mise en place des b ches Si les b ches gaz ont t plac es en usine elles n ont pas besoin d tre replac es Siles b ches ont t emball es s par ment reportez vous aux instructions d installation qui accompagnent les b ches Conservez les instructions relatives aux b ches avec ce manuel En cas de formation de suie il est possible que les b ches aient beso
30. e votre foyer Assurez vous que les flammes soient r guli res elles ne doivent pas s lever ou flotter Voir Figure 14 Les pointes du dispositif thermopile thermocouple veilleuse doivent tre entour es de flammes Voir Figure 6 Entretien et service de votre appareil suite Maintaining and Servicing Your Appliance continued V rification du syst me d vacuation Fr quence Avant la premi re utilisation puis au moins une fois l an plus souvent si possible Par Technicien de service qualifi Propri taire T che Inspectez r guli rement le capuchon d vacuation externe afin de v rifier que la circulation de l air ne soit pas entrav e par des d bris Inspectez l ensemble du syst me d vacuation afin de v rifier qu il fonctionne correctement Checking Vent System Frequency Before initial use and at least annually thereafter more frequently if possible By Qualified service technician Home owner Task Inspect the external vent cap on a regular basis to ensure that no debris is interfering with the flow of air Inspect entire vent system for proper function Cleaning Glass Door Frequency As necessary By Home owner Task Clean as necessary particularly after adding new ember flame colorant material Film deposits on the inside of the glass door should be cleaned off using a household glass cleaner NOTE DO NOT handle or attempt to clean Nettoyage de la porte en verre Fr q
31. er les br lures et l enflammement de v tements Les enfants en bas ge doivent tre SURVEILLES ATTENTIVEMENT lorsqu ils se trouvent dans la m me pi ce que l appareil Ces appareils DOIVENT utiliser l un des syst mes d vacuation d crits dans la section intitul e Installation de la cassette dans le Guide d installation AUCUN AUTRE syst me ou l ment d vacuation NE PEUT ETRE UTILISE Cet appareil gaz et ce syst me d vacuation DOIVENT vacuer les gaz de combustion directement l ext rieur et NE DOIVENT JAMAIS tre raccord s une chemin e desservant un autre appareil combustible solide Chaque appareil gaz DOIT UTILISER un syst me d vacuation distinct L utilisation de syst mes d vacuation en commun est INTERDITE INSPECTEZ r guli rement le capuchon d vacu ation ext rieur afin de vous assurer que la circulation de l air ne soit pas entrav e par des d bris La porte en verre DOIT tre en place et herm tiquement ferm e et l ensemble de la porte de garniture DOIT tre en place sur le foyer pour que l appareil puisse fonctionner en toute s curit NE FAITES PAS FONCTIONNER cet appareil si la porte en verre est d mont e f l e ou bris e La porte en verre doit tre chang e par un technicien de service agr ou qualifi NE frappez et NE claquez PAS la porte en verre La porte en verre DOIT tre chang e UNIQUEMENT en tant qu unit compl te telle qu elle est fournie par l
32. es de rechange IMPORTANT THIS IS DATED INFORMATION The most current information is located on your dealers VIP site When ordering supply serial and model numbers to ensure correct service parts IMPORTANT L information fournie dans cette brochure n est valide que pendant une courte p riode Les sites VIP des distributeurs disposent des renseignements les plus r cents Lors d une commande veuillez fournir les num ros de s rie et de mod les pour un remplacement ad quat des pi ces PIECE D ALLUMAGE PAR VEILLEUSE ROBERT SHAW VALVE N DE SERIE N DE PIECE 2 Burner Orifice NG 33A Orifice de br leur GN 233A d 438 800 2 Burner Orifice LP 51A Orifice de br leur PL 51A NE 438 803 Approvals and Codes Homologations et codes Approval Listing and Codes Appliance Certification The Heat N Glo models discussed in this nstallers Guide have been tested to certification standards and listed by the applicable laboratories CERTIFICATION STANDARD MODEL AT Supreme C Underwriters Laboratories LABORATORY TYPE Direct Vent Gas Fireplace Heater STANDARD ANSI Z21 88 CSA2 33 UL307B Installation Codes The appliance installation must conform to local codes Before installing the appliance consult the local building code agency to ensure that you are in compliance with all applicable codes including permits and inspections In the absence of local codes the appliance installation must conform to the
33. et approuv s pour fonctionner entre 0 et 610 m tres d altitude aux Etats Unis et entre 0 et 1 370 m tres d altitude au Canada Si cet appareil est install une altitude sup rieure 610 m tres aux Etats Unis il peut s av rer n cessaire de r duire l admission du gaz en diminuant l ouverture de l orifice du br leur L admission doit tre r duite de quatre pour cent 4 96 par 305 m tres au dessus du niveau de la mer moins que le pouvoir calorifique du gaz ait t r duit Dans ce cas cette r gle g n rale ne s applique pas Pour connaitre l ouverture de l orifice qui convient consultez le service local de distribution de gaz Si cet appareil est install entre 610 et 1 370 m tres d altitude au Canada l admission du gaz doit tre r duite de dix pour cent 10 96 Si cet appareil est install une altitude sup rieure 1 370 m tres au Canada consultez les autorit s locales Consultez votre service local de distribution de gaz afin de d terminer le diam tre de l orifice requis pour votre r gion Getting Started Comment d buter Introducing the Heat N Glo Gas Appliances Heat N Glo direct vent gas appliances are designed to oper ate with all combustion air siphoned from outside of the build ing and all exhaust gases expelled to the outside The infor mation contained in this nstallers Guide unless noted oth erwise applies to all models and gas control systems Gas appliance di
34. gueur excessive de conduit flexible dans la chemin e Re fixez le support de collet sur la fa ade de l appareil l aide d une vis t le Fixez le raccord conduit capuchon sur le capuchon et le haut du conduit flexible puis mettez le capuchon en place en haut de la chemin e Consultez les Figures 3 4 et 5 ATTENTION POUR VITER LES PROBLEMES DE REFOULEMENT ET OU DE COURANTS D AIR FROID IL EST RECOMMAND DE BOUCHER HERM TIQUEMENT L ESPACE ENTRE LE CAPUCHON ET LE HAUT DE L OUVERTURE DE LA CHEMIN E COMBUSTIBLE SOLIDE SUR LAQUELLE LE CAPUCHON A T INSTALL AVEC LE SYSTEME D VACUATION LINK DV4 30 IL EST OBLIGATOIRE DE BOUCHER HERM TIQUEMENT LES JOINTS DES CONDUITS FLEXIBLES AUTOUR DU REGISTRE CONSULTEZ LA FIGURE 3 UTILISEZ DE L ISOLANT DE FIBRE DE VERRE OU UN AUTRE MAT RIAU NON COMBUSTIBLE ADAPT HOMOLOGATION DU SYST ME D VACUATION LINK DV30 LINK DV4 30 AT Supreme C TABLEAU 1 Installing the Insert continued WARNING MAJOR U S BUILDING CODES SPECIFY MINIMUM CHIMNEY AND OR VENT HEIGHT ABOVE THE ROOF TOP THESE MINIMUM HEIGHTS ARE NECESSARY IN THE INTEREST OF SAFETY SEE THE FOLLOWING DIAGRAM FOR MINIMUM HEIGHTS PROVIDED THE TERMINATION CAP IS AT LEAST 2 FEET FROMA VERTICAL WALL AND 2 FEET BELOW A HORIZONTAL OVERHANG Installation de la cassette suite AVERTISSEMENT LES PRINCIPAUX CODES DE CONSTRUCTION AM RICAINS D FINISSENT LA HAUTEUR MINIMALE DE LA CHEMIN E ET OU DU CONDUI
35. in d tre l g rement repositionn es afin d viter un empi tement excessif sur les flammes Mise en place des braises Deux sacs diff rents de braises sont livr s avec cet appareil gaz Lesac tiquet Golden Ember GE 93 est un colorant de flammes Lesac tiquet Glowing Ember 050 721 est une imi tation standard de braises incandescentes Pour mettre les braises en place Retirez la porte de garniture en la soulevant et en la d gageant de l appareil Ouvrez les verrous en haut et en bas de la porte en verre Retirez la porte en verre de l appareil Couvrez le dessus du br leur d une seule couche de braises puis saupoudrez le br leur de GE 93 Conservez le reste des braises afin de pouvoir les utiliser lors de l entretien du foyer Replacez la porte en verre R installez la porte en verre et verrouillez la e Replacez la porte de garniture Installing the Insert continued Installation de la cassette suite 1 Soulevez la porte de garniture pour la retirer de 1 Liftthe top trim door up and out of the unit PATCHES l appareil 2 Unlatch and remove the ab et M glass door from the unit VERROUS EN 2 D verrouillez et retirez la SORTE porte en verre de l appareil GLASS SPECIFICATIONS SPECIFICATIONS DE LA VITRE RUP LE ASSEMBLY 794 mm x778 mm on eee 7 2 C RAMIQUE Figure 10 Figure 10 Glass Assembly Porte en
36. ion il est conseill de demander un technicien de service qualifi d inspecter l appareil au d but de chaque saison de chauffage Vous trouverez ci dessous des directives sp cifiques chaque op ration de maintenance de l appareil IMPORTANT FERMEZ LE GAZ AVANT TOUT SERVICE D ENTRETIEN DE VOTRE APPAREIL Remplacement des braises usag es Fr quence Une fois l an lors du service Par Technicien de service qualifi T che l aide d une brosse nettoyez les r sidus de braises aux environs du br leur Remplacez les braises usag es par de nouveaux morceaux de braises Golden Ember DE 93 et Glowing Ember 050 721 de la taille et de la forme d une pi ce de dix cents Alternez les couches de braises sur le br leur une couche de Golden Ember une couche de Glowing Ember etc Conservez la balance des braises et r p tez l op ration lors du prochain service d entretien Pour plus d informations voir Mise en place des braises dans le Guide d installation Nettoyage du br leur et des commandes Fr quence Une fois l an Par Technicien de service qualifi T che Nettoyez au moyen d une brosse ou d un aspirateur le boitier de commandes les b ches du foyer et les environs du br leur proximit des b ches V rification de la forme et de la hauteur des flammes Fr quence P riodiquement Par Technicien de service qualifi Propri taire T che V rifiez visuellement la forme des flammes d
37. lation de l appareil RESTENT PROPRES afin de permettre une circulation suffisante d air de combustion et de ventilation A Ne PLACEZ jamais de mat riaux combustibles essence ou autres vapeurs ou liquides inflammables proximit de l appareil NEVER OBSTRUCT the flow of combustion and ventilation air Keep the front of the appliance CLEAR of all obstacles and materials for servicing and proper operations Due to the high temperature the appliance should be LOCATED out of traffic areas and away from furniture and draperies Clothing or flammable material SHOULD NOT BE PLACED on or near the appliance Children and adults should be ALERTED to the hazards of high surface temperature and should STAY AWAY to avoid burns or clothing ignition Young children should be CAREFULLY SUPERVISED when they are in the same room as the appliance These units MUST use one of the vent systems described in the Installing the Insert section of the Installers Guide NO OTHER vent systems or components MAY BE USED This gas fireplace and vent assembly MUST be vented directly to the outside and MUST NEVER be attached to a chimney serving a separate solid fuel burning appliance Each gas appliance MUST USE a separate vent system Common vent systems are PROHIBITED INSPECT the external vent cap on a regular basis to make sure that no debris is interfering with the air flow The glass door assembly MUST be in place and sealed and the trim door
38. m side to side and from front to back If necessary use the legs included in the manual bag Screw the legs into the nuts installed in the bottom rear of the insert Turn legs in until insert is level Step 3 The Gas Control Systems WARNING THIS UNIT IS NOT FOR USE WITH SOLID FUEL The gas control system used with this model is Standing Pilot Ignition Standing Pilot Ignition System This system includes millivolt control valve standing pilot thermopile thermocouple flame sensor and piezo ignitor WARNING 110 120 VAC MUST NEVER BE CONNECTED TO A CONTROL VALVE IN A MILLIVOLT SYSTEM Installation de la cassette suite tape 2 Emplacement nivellement et solidification de la cassette 1 Placez la cassette l emplacement d sir 2 Nivelez la cassette d un c t l autre et de l avant l arri re Sin cessaire utilisez les pieds inclus dans la pochette du manuel Vissez les pieds dans les crous install s au bas de la cassette l arri re Vissez les pieds jusqu ce que la cassette soit nivel e tape 3 Syst mes de commande de gaz AVERTISSEMENT CET APPAREIL NE DOIT PAS TRE UTILIS AVEC DES COMBUS TIBLES SOLIDES Le type de commande de gaz utilis sur ce mod le est l allumage par veilleuse Syst me d allumage par veilleuse Ce syst me comprend une valve de commande millivolt une veilleuse un d tecteur de flamme thermopile thermocouple et un allumeur pi zo
39. merez l appareil il faudra quelques minutes pour que les conduits se purgent de cet air Une fois la purge termin e l appareil s allumera et fonctionnera normalement Les prochaines fois que vous allumerez l appareil les conduits gaz ne contiendront pas d air vacuer moins que la valve de commande n ait t ferm e Dans ce cas l air devra tre vacu REMARQUE Vous devez faire fonctionner le foyer pendant 8 heures la premi re fois que vous l allumez Cela permet de mieux liminer les produits chimiques utilis s dans la peinture et les b ches tape 10 Allumage de l appareil Vous avez revis toutes les consignes de s curit vous avez v rifi que l appareil ne pr sentait aucune fuite de gaz vous savez que le syst me d vacuation est bien d gag et vous avez v rifi qu aucun l ment n tait d fectueux Vous tes d sormais pr t allumer l appareil AVERTISSEMENT VEUILLEZ VOUS REPORTER AU MODE D EMPLOI POUR CONNAITRE TOUTES LES CONSIGNES DE SECURITE RELA TIVES A L ALLUMAGE ET AU FONCTION NEMENT DE L APPAREIL Apres l installation GARDEZ CE MANUEL D INSTALLATION AVEC L APPAREIL POUR POUVOIR VOUS Y REPORTER ULTERIEUREMENT Maintaining and Servicing Your Appliance Entretien et service de votre appareil Appliance Maintenance Although the frequency of servicing and maintenance will depend on use and the type of installation you should have a qualified service technicia
40. minum or stainless steel gas vent is used for both the incoming combustion air and exhaust vent pipes NO OTHER VENTING SYSTEMS OR COMPONENTS MAY BE USED Detailed installation instructions are included with each vent termination kit and should be used in conjunction with this manual Horizontal Venting The vent system on this model CANNOT be terminated horizontally Vertical Venting The vent pipes MUST be connected to the proper collars on the unit AND the exhaust vent pipe MUST be connected to the termination cap or the unit will not operate The combustion air vent pipe CAN be connected to the termination cap or it can terminate inside the chimney The bottom opening of the chimney must be sealed around the vent pipes if the combustion air vent is NOT connected to the termination cap See Figures 3 4 and 5 NOTE The minimum vertical rise exhaust vent is 14 feet and the maximum vertical rise is 50 feet These dimensions are measured from the starting collars of the unit to the end ofthe last section of vent pipe See dimension V in Figure 3 Installation de la cassette tape 1 Installation du syst me d vacuation Pr cautions d installation du syst me d vacuation Avant de commencer installer les modules d vacuation l installateur doit lire ces instructions et celles des modules d vacuation afin d obtenir une installation correcte Consultez les codes de construction de votre r gion avant de commencer l install
41. must be left with appliance for future reference AVERTISSEMENT Une installation un r glage une modification une r paration ou un service incorrects risquent d entrainer des blessures ou des dommages mat riels Consultez ce manuel Pour obtenir de l aide ou des informa tions suppl mentaires consultez un installateur qualifi une agence de maintenance ou le fournisseur de gaz Lisez ce manuel avant d installer ou d utiliser cet appareil Ce Guide d installation doit rester avec l appareil pour r f rence ult rieure SAFETY AND WARNING INFORMATION CONSIGNES DE S CURIT ET MISES EN GARDE A READ and UNDERSTAND all instructions LISEZ ATTENTIVEMENT lesi i carefully before starting the installation FAILURE A LIS uen D Me TO FOLLOW these installation instructions may result in a possible fire hazard and will void the warranty A Prior to the first firing of the fireplace READ the Using Your Fireplace section of the Owners Guide N DONOTUSEthis appliance if any part has been under water Immediately CALL a qualified service technician to inspect the unit and to replace any part of the control system and any gas control which has been under water THIS UNIT IS NOT FOR USE WITH SOLID FUEL Installation and repair should be PERFORMED by a qualified service person The appliance and venting system should be INSPECTED before initial use and at least annually by a professional
42. n perform an appliance check up at the beginning of each heating season Specific guidelines regarding each appliance maintenance task are listed below IMPORTANT TURN OFF THE GAS BEFORE SERVICING YOUR APPLIANCE Replacing old ember material Frequency Once annually during the checkup By Qualified service technician Task Brush away loose ember material near the burner Replace old ember material with new dime size and shape pieces of Golden Ember DE 93 and Glowing Ember 050 721 New ember material should be placed alternately on top of the burner a layer of Golden Ember a layer of Glowing Ember and so on Save the remaining ember material and repeat this procedure at your next servicing For more information see Placing Ember Material in the Installers Guide Cleaning Burner and Controls Frequency Once annually By Qualified service technician Task Brush or vacuum the control compartment fireplace logs and burner areas surrounding the logs Checking Flame Patterns Flame Height Frequency Periodically By Qualified service technician Home owner Task Make a visual check of your fireplace s flame patterns Make sure the flames are steady not lifting or floating See Figure 14 The thermopile thermocouple standing pilot tips should be covered with flame See Figure 6 27 Entretien de l appareil Bien que la fr quence de l entretien et des services d pende de l utilisation et du type d installat
43. odes locaux ou en l absence de codes locaux au code am ricain National Electric Code ANSI NFPA n 70 aux tats Unis ou au Code lectrique canadien CSA C22 1 au Canada Ces mod les peuvent tre install s dans une chambre coucher ou une chambre salon aux Etats Unis et au Canada Approvals and Codes continued Homologations et codes suite High Altitude Installations U L Listed gas appliances are tested and approved for elevations from 0 to 2 000 feet in the U S A and are tested and approved for elevations from 0 to 4 500 feet in Canada When installing this appliance at an elevation above 2 000 feet in the United States it may be necessary to decrease the input rating by changing the existing burner orifice to a smaller size Input should be reduced four percent 496 for each 1 000 feet above sea level unless the heating value of the gas has been reduced in which case this general rule will not apply To identify the proper orifice size check with the local gas utility When installing this appliance at an elevation between 2 000 and 4 500 feet in Canada the input rating must be reduced by ten percent 10 When installing this appliance at an elevation above 4 500 feet in Canada check with local authorities Consult your local gas utility for assistance in determining the proper orifice for your location Installation haute altitude Les appareils gaz homologu s U L ont t test s
44. ollecteur Utilisez un petit tournevis plat pour entrouvrir la vis au centre de la d rivation Placez un tuyau en caoutchouc sur la d rivation pour mesurer la pression Le foyer et son robinet individuel DOIVENT tre isol s de la tuyauterie d alimentation en gaz pendant les contr les de pression du syst me des pressions d essai sup rieures 3 5 kPa Le foyer DOIT tre isol de la tuyauterie d alimentation en gaz en fermant son robinet individuel pendant les contr les de pression de la tuyauterie d alimentation en gaz des pressions d essai inf rieures ou gales 3 5 kPa Installing the Insert continued Step 6 Wiring the Fireplace NOTE Electrical wiring must be installed by a licensed electrician CAUTION DISCONNECT REMOTE CONTROLS IF YOU ARE ABSENT FOR EXTENDED TIME PERIODS THIS WILL PREVENT ACCIDENTAL FIREPLACE OPERATION For Standing Pilot Ignition Wiring Appliance Requirements This appliance DOES NOT require 110 120 VAC to oper ate WARNING DO NOT CONNECT 110 120 VAC TO THE GAS CONTROL VALVE OR THE APPLIANCE WILL MALFUNCTION AND THE VALVE WILL BE DESTROYED Optional Accessories Optional fan and remote control kits require that 110 120 VAC be supplied to the factory installed junction box Run the cord out the notch in the surround and plug into a convenient outlet Wall Switch Position the wall switch in the desired position on a wall Run a maximum of 25 feet
45. ra utilis e Latuyauterie d alimentation en gaz Si vous d sirez installer des accessoires facultatifs dispositifs tels qu un interrupteur mural ou une commande distance Figure 1 Sch ma de la cassette AT Supreme C r 9 16 39 4mm ELECTRICAL So 14 5 8 371 5mm 13 5 8 345 5mm 28 7 8 732 6mm GAS LINE ACCESS t ACCESS 9 13 16 ACCES DU 249 93mm FILAGE LECTRIQUE 13 5 8 344 8mm EX ACC S DU CONDUIT GAZ 21 16 2234 575 5mm 15 508 7mm 57 2mm L Y 517mm x 41 8 105 1mm LL 47 8 124 3mm 892T7Tl8 835 1mm EXHAUST STARTING COLLAR COLLET DE RACCORD DU SYSTEME D EVACUATION INLET AIR STARTING COLLAR COLLET DE RACCORD DU CONDUIT D ADMISSION D AIR GAS ACCESS ACCES DU CONDUIT A GAZ MINIMUM APPLIANCE SIZE FRONT WIDTH REAR WIDTH DEPTH TOP VIEW HEIGHT VUE DU DESSUS GLASS DOOR PORTE EN VERRE GAS CONTROLS amp RATING PLATE BEHIND GRILL COMMANDES DE GAZ ET PLAQUES SIGNAL TIQUES DERRIERE LA GRILLE F 1 10 1 2 266 7mm SURROUND CHOSES 2 FAN ACCESS ELECTRICAL ACCESS ACCES A
46. rifice d admission de la valve de commande de 13 mm 1 2 po REMARQUE Veuillez consulter les codes locaux pour vous assurer que les l ments de remplacement sont r glementaires Le conduit gaz peut arriver d un c t ou de l autre du foyer condition que l orifice pratiqu dans l ext rieur du foyer ne d passe pas 50 8 mm de diametre et que le conduit ne p n tre pas dans le foyer herm tique L cart entre la tuyauterie d approvisionnement et l orifice d acc s du conduit gaz peut tre bouch l aide d isolant non combustible pour emp cher l infiltration d air froid Rep rezl orifice d acc s du conduit gaz dans la paroi ext rieure de la cassette Ouvrez la grille inf rieure ins rez le conduit gaz dans l orifice d acc s du conduit gaz et branchez le au robinet e Pour brancher le tuyau soutenez la commande afin que les conduits ne soient pas tordus ou rompus e Une fois l installation du conduit gaz termin e utilisez une solution savonneuse pour d tecter des fuites sur tous les raccords de gaz AVERTISSEMENT N UTILISEZ PAS DE FLAMME NUE POUR DETECTER DES FUITES DEGAZ USE A WRENCH MANUAL ON SHUT OFF VALVE SHUT OFF VALVE WHEN TIGHTENING ROBINET MANUEL GAS LINE c arias UNE CL SUR LE ROBINET DE GAZ LORS DU SERRAGE DU CONDUIT GAZ GAS VALVE VE DE VAL COMMANDE DE GAZ FLEX CONNECTOR TUYAU FLEXIBLE Installing the Insert continued Installation de la
47. se of kit FLASH DAMP will seal off the damper opening when terminating the inlet air vent pipe just above the damper These two kits are recommended for zero clearance factory built woodburning fireplaces Connecting the Vent Pipe Install the 3 inch flexible vent pipes down through the chimney Remove the starting collar bracket from the top of the unit See figure 5 Attach and secure the bottom ends of the flex pipes to the starting collar bracket with 3 sheetmetal screws on each collar Slide the gas insert into place and position any excess flex vent pipe back up into the chimney Re attach the collar bracketto the unit with one sheetmetal screw through the front ofthe unit Attach the pipe to cap adaptor to the termination cap and the top of the flexible vent pipe and set the cap in place at the top of the chimney See Figures 3 4 amp 5 CAUTION TO AVOID DOWNDRAFTS AND OR COLD AIR PROBLEMS IT IS RECOMMENDED TO SEAL OFF THE AREA BETWEEN THE TERMINATION CAPAND THE TOP OF THE SOLID FUEL CHIMNEY OPENING INTO WHICH THE VENT CAP HAS BEEN INSTALLED WHEN USING THE LINK DV4 30 VENT SYSTEM IT IS REQUIRED TO SEAL AROUND THE FLEXIBLE VENT PIPES IN THE DAMPER AREA SEE FIGURE 3 USE FIBERGLASS INSULATION OR OTHER SUITABLE NON COMBUSTIBLE MATERIAL VENT SYSTEM APPROVALS LINK DV30 LINK DV4 30 AT Supreme C TABLE 1 Un syst me d vacuation a terminaison verticale install sur ce mod le doit inclure un 1 conduit flexible
48. service person More frequent cleaning may be required due to excessive lint from carpeting bedding material etc It is IMPERATIVE that the unit s control compartment burners and circulating air passageways BE KEPT CLEAN to provide for adequate combustion and ventilation air gt gt Always KEEP the appliance clear and free from AN combustible materials gasoline and other flammable vapors and liquids avant de commencer l installation Si ces instructions d installation ne sont pas suivies un risque d incendie pourrait en r sulter et la garantie sera annul e AN Avant l allumage initial LISEZ la section du Guide de l utilisateur intitul e Utilisation de votre foyer VAN N UTILISEZ PAS cet appareil si une pi ce a t submerg e APPELEZ imm diatement un technicien de service qualifi pour l inspection de l appareil et le remplacement de toute pi ce qui fut submerg e IN CET APPAREIL N EST PAS CONCU POUR TRE UTILIS AVEC DES COMBUSTIBLES SOLIDES AN L installation et les r parations doivent tre EFFECTU ES par un technicien de service qualifi L appareil et le syst me d vacuation doivent tre INSPECTES avant la premi re utilisation et au moins une fois l an par un technicien professionnel Un nettoyage plus fr quent peut s av rer n cessaire en cas d accumulation de fibres de tapis de literie etc Il est IMPERATIF que le boitier de commandes les br leurs et les conduits d air de circu
49. t continued Installation de la cassette suite Step 9 Before Lighting the Appliance Before lighting the appliance do the following Review safety warnings and cautions e Read the Safety and Warning Information section at the beginning of this Installers Guide Double check for gas leaks Before lighting the appliance double check the unit for possible gas leaks Double check vent terminations and front grilles for obstructions Before lighting the appliance double check the unit for possible obstructions that could be blocking the vent terminations or the front grilles Double check for faulty components Any component that is found to be faulty MUST BE replaced with an approved component Tampering with the appliance components is DANGEROUS and voids all warranties A small amount of air will be in the gas supply lines When first lighting the appliance it will take a few minutes for the lines to purge themselves of this air Once the purging is complete the appliance will light and will operate normally Subsequent lightings of the appliance will not require this purging of air from the gas supply lines unless the gas valve has been turned to the OFF position in which case the air would have to be purged NOTE The fireplace should be run for 8 hours on the initial start up This will help to cure the chemicals used in the paint and logs Step 10 Lighting the Appliance You ve reviewed all safet
50. ttached to outer right side of the insert See Figure 12 Disconnect the ON OFF switch from the low voltage wire leads and insert the ON OFF switch through the hole at the upper right corner of the surround it will be retained in the hole 24 REMARQUE RETIREZ L ENSEMBLE DE LAPORTE DE GARNITURE AVANT ET LA PORTE EN VERRE DE LA CASSETTE AVANT D INSTALLER L ENTOURAGE 1 Rep rez les fils h licoidaux de basse tension et l interrupteur MARCHE ARR T attach s l ext rieur du c t droit de la cassette Voir Figure 12 2 D branchez l interrupteur MARCHE ARR T des fils de basse tension et ins rez le dans l orifice situ dans le coin sup rieur droit de l entourage Il restera en place dans l orifice Installing the Insert continued Installation de la cassette suite 3 Run the low voltage lead wires up the back of the right 3 Faites monter les fils de basse tension le long du c t side of the surround and secure them with the three wire droit de l entourage et fixez les l aide des trois liens ties found there Re connect the low voltage wires to the m talliques qui s y trouvent Rebranchez les fils de basse ON OFF switch tension l interrupteur MARCHE ARR T 4 Remove and retain the four surround attachment screws 4 Retirez et conservez les quatre vis de fixation de atthe corners of the face of the unit See Figure 12 l entourage situ es aux coins de la facade de l appareil I I PS Voir Figure 12 5 Slide
51. uence Selon les besoins Par Propri taire T che Nettoyez selon les besoins en particulier apr s avoir ajout des braises colorant de flammes Nettoyez la pellicule de d p ts sur l int rieur de la porte en verre avec du nettoyeur vitre REMARQUE Ne manipulez et the door when it is hot and DO NOT use abrasive cleaners ASSUREZ VOUS QUE LES FLAMMES SOIENT REGULIERES QU ELLES NE n essayez PAS de nettoyer la porte lorsqu elle est chaude et n utilisez PAS de produit S L VENT PAS ET NE FLOTTENT PAS d entretien abrasif MAKE SURE THE FLAMES ARE STEADY NOT LIFTING OR FLOATING Figure 14 Forme des flammes du br leur Figure 14 Burner Flame Patterns ANSI RAB ES QMS A Heat N Glo Quality Systems registered by SGS ICS i ANSI RAB ES X Heat N Glo vum stems s registered by SGS ICS aii Contacter le concessionnaire Heat N Glo pour toute question ou tout probl me Pour obtenir le num ro de t l phone du concessionnaire Heat N Glo le plus proche t l phoner au 952 985 6000 Heat N Glo division de Hearth Technologies Inc 20802 Kensington Boulevard Lakeville MN 55044 Imprim aux Etats Unis Copyright 2000 Ce produit est prot g par un our plusieurs des brevets suivants tats Unis 4 112 913 4 408 594 4 422 426 4 424 792 4 520 791 4 793 322 4 852 548 4 875 464 5 000 162 5 016 609 5 076 254 5 191 877 5 218 953 5 328 356 5 429 495 5 452 708 5 542 4
52. ustible insulation to pre vent cold air infiltration Locate the gas line access hole in the outer casing of the insert Openthe lower grille insert the gas supply line through the gas line hole and connect it to the shut off valve When attaching the pipe support the control so that the lines are not bent or torn After the gas line installation is complete use a soap solution to carefully check all gas connections for leaks WARNING DO NOT USE AN OPEN FLAME TO CHECK FOR GAS LEAKS GAS ACCESS ACCES DU CONDUIT GAZ Figure 7 Gas Supply Line Installation de la cassette suite tape 4 Conduit gaz REMARQUE Le conduit gaz doit tre install conform ment aux codes de construction locaux L installation doit tre effectu e par un technicien qualifi et ou muni d une licence de mani re re specter les r glements municipaux REMARQUE Avant d allumer le foyer pour la premi re fois toutes les bulles d air doivent tre vacu es du conduit gaz REMARQUE Consultez les codes de construction locaux pour choisir correctement le diam tre du conduit gaz s acheminant vers le raccord de 13 mm du foyer Ce foyer gaz est concu pour accepter un conduit gaz de 13 mm Pour installer le conduit gaz Unrobinet manuel poign e en T de 13 mm 1 2 po homologu et approuv par l Etat du Massachusetts et un tuyau gaz flexible homologu sont branch s l o
53. y warnings you ve checked the appliance for gas leaks you know the vent system is unobstructed and you ve checked for faulty components Now you re ready to light the appliance WARNING PLEASE REFER TO THE USER S MANUAL FOR ALL CAUTIONS SAFETY AND WARNING INFORMATION PERTAINING TO THE LIGHTING AND OPERATION OF THE APPLI ANCE After the Installation LEAVE THIS INSTALLATION MANUAL WITH THE APPLIANCE FOR FUTURE REFERENCE Etape 9 Avant d allumer l appareil Avant d allumer le foyer effectuez les op rations suivantes Revisez les consignes de s curit et les mises en garde Lisez la section Consignes de s curit et mises en garde au d but de ce Guide d installation V rifiez qu il n y ait pas de fuites de gaz Avant d allumer l appareil v rifiez nouveau qu il ne pr sente pas de fuites de gaz V rifiez qu il n y ait pas d obstructions dans les terminaisons du syst me d vacuation et dans les grilles avant Avantd allumer l appareil v rifiez une fois de plus qu il n y ait pas d obstructions dans les terminaisons du syst me d vacuation et dans les grilles avant de l appareil V rifiez qu il n y ait pas d l ments d fectueux Tout l ment d fectueux DOIT ETRE remplac par un l ment approuv Il est DANGEREUX de modifier les l ments de l appareil et ceci annule toutes les garanties Les conduits gaz contiendront une petite quantit d air La premi re fois que vous allu