Home

PROFIL100EINT

image

Contents

1. Rangs Code ue Rangs Code Ds Rangs Code prete 00 34 68 01 35 69 02 36 70 03 37 71 04 38 T2 05 39 T3 06 40 74 07 41 75 08 42 76 09 43 77 10 44 78 11 45 79 12 46 80 13 47 81 14 48 82 15 49 83 16 50 84 117 51 85 18 52 86 19 53 87 20 54 88 21 55 89 22 56 90 23 57 91 24 58 92 25 59 93 26 60 94 27 61 95 28 62 96 29 63 97 30 64 98 31 65 99 32 66 33 67 RAPPEL Du iano G0 TA 59 i Du dan an 99 cdvi com cdvigroup com 17 Tapez 2 fois le code maitre Temporisation clairage clavier Temporisation relais 1 A1 Temporisation relais 2 A2 Nombre de termes A4 Code maitre A5 La led verte s allume is 1 x bip 10 99 sec 00 continue 1 x bip OK 4 bips ERREUR La led verte s allume is 1 x bip La led verte s allume is 1 x bip La led verte s allume is 1 x bip La led verte s allume is 1 x bip continue 01 D faut 1 x bip OK 4 bips ERREUR 01 99 sec 00 continue 01 D faut 1 x bip OK 4 bips ERREUR 4 5 ou 6 chiffres 5 D faut 1 x bip OK 4 bips ERREUR 4 5 ou 6 chiffres 12345 D faut 1 x bip OK 4 bips ERREUR cdvi com 18 cdvigroup com MANUEL D INSTALLATION PROFIL100EINT i pe Clavier cod r tro clair avec lectronique int gr U Ma UUU A6 Termes de modification relais 1
2. Insert the 2 plastic anchors in the holes Mount the back plate of the PROFIL100EINT with the screw on the wall Fasten the PROFIL100EINT keypad to the back plate with the M5x8 Diax screw and T20 Diax spanner hardware cdvi com cdvigroup com 3 5 WIRING DIAGRAM LOOEINT Black d Mullion Weatherproof Keypad Self Contained INT1 INT2 Input voltage Code change Memory reset 12 to 24V ac 230V by the user switch or 12 to 48V dc set the switch set the switch to ON to ON Light bleu y y Light green dh Eh INT1 INT2 Dark green Dark blue oo oH go ahl qo Transmission strike Locked power supply Outputs Descri Black Input voltage 12V to 24V ac or 12V to 48V dc Red Power supply of 12V to 24V ac or 12V to 48V dc Pink Request to exit input relay 1 Purple Common Light blue Timer Contact Dark blue N C contact relay 2 Dark green Common relay 2 Light green N O contact relay 2 Orange N C contact relay 1 Yellow Common relay 1 Brown N O contact relay 1 white Output to prevent removal Grey Output to prevent removal This product is delivered with a varistor The varistor must be installed directly on the terminals of the strike electromagnetic lock motor etc controlled by the device If the device operates with several strikes each m
3. signals It can be turned off by cutting the ST1 wire on the remote controller 1 short beep Keypad powered 1 long beep Data computing in programming or access granted A RESET MASTER CODE AND USER CODES 1 Enter the master code twice 1 23 45 default value master code The red LED lights on 2 beeps are emitted to confirm entry in programming mode 2 Press A6 to reset the Master Code and the User codes The green LED lights on during 1 second One beep is emitted Press on A and B to confirm reset of all memory of the keypad The green LED lights on Wait until the LED lights off Wait for two beeps The master code is restored to its default value 12345 and all the User codes are deleted from the keypad The keypad is reset the red LEDs remain on and then turn off Once the reset is completed then the keypad returns to a stand by operating mode OR 1 Cut the power Place the jumper on P2 2 Put the power back The green LED lights on Wait approximately 3 seconds one beep is emitted be used as a PIN code User Pin code To delete a specific User pin Code replace it by 0000 if code length is 4 digits format or replace itby 00000 if the code is in 5 digits format Consumption With the 2 relays controlled and permanent lighting At 12V dc max 90mA At 12V ac max 70mA At 24V dc max 50mA At 24V ac max 40mA The green LED lig
4. PROFILIOOEINT Range Digicode Gamme Digicode INSTALLATION MANUAL MANUEL D INSTALLATION CDV I Group Products 1 PRODUCT PRESENTATION m Construction Stainless steel a m Capacity of 100 user codes H RY of 4 to 6 digits HIGH RESISTANCE TO Stored in non volatile EPROM memory m Buzzer audible signal m 13 backlit keys o o m Illumination mode permanent or timed D m High resistance to vandalism HRV m Master code and the User codes can be ORO of 4 to 6 digit in length m 100 user codes m 2 Form C Relay outputs 6A at 250V relay 2 oO 1A at 120V relay ORO m Adjustable time output 1 to 99 seconds select 00 for toggle mode m 1 Request to Exit input m 1 Requeest to Enter Key m Operating voltage 12 to 24V ac and 12 to 48V dc m Input voltage 12 to 24V ac or 12 to 48V dc m Consumption 25 to 80mA m Recommended for activating 64 and desactivating your alarm system eters te C CE Certification PR de d i A a power supplies m Mounting with Diax screws 25 C to 70 C m Dimensions L x W x D 165 x 43 x 27 mm m User modification of codes K WEEE amp RoHS 2 D D TE 2 NOTES amp RECOMMENDATIONS Recommended power supplies Security advice suitable for the PROFIL100EINT For security advice reasons change ARD12 230V input BS60 230V input the factory default master code Separate power supply for the control eleme
5. A7 Termes de modification relais 2 A8 Signal sonore AA La led verte La led verte La led verte La led verte s allume is s allume is s allume is s allume is 1 x bip 1 x bip 1 x bip 1 x bip Taper A ensuite B 2 chiffres AB D faut 1 x bip OK 4 bips ERREUR 2 chiffres 13 D faut 1 x bip OK 4 bips ERREUR 0 supprimer les bips 1 autoriser les bips 1 x bip OK 4 bips ERREUR Programmation des codes 00 99 4 bips rang occup 1 bip rang libre Tapez B pour sortir de la programmation cdvi com cdvigroup com 19 Extranet EXE CDVI_IM PROFIL100EINT CMYK A5 EN FR 01 Reference GO301FRO269V02 Manufacturing Access Control since 1985 CDVI Headquarters Si ge social FRANCE Phone 33 0 1 48 91 01 02 Fax 33 0 1 48 91 21 21 CcDVI AMERICAS Phone 1 450 682 7945 Fax 1 450 682 9590 CcDVI BENELUX Phone 32 0 56 62 02 50 Fax 32 0 56 62 02 55 CcDVI TAIWAN Phone 0 42471 2188 Fax 0 42471 2131 CDVI SWITZERLAND Phone 41 0 21 882 18 41 Fax 41 0 21 882 18 42 CDVI CHINA Phone 86 0 10 87664065 Fax 86 0 10 87664165 CDVI IBERICA Phone 34 935 390 966 Fax 34 935 390 970 CDVI ITALIA Phone 39 0331 97 38 08 Fax 39 0331 97 39 70 cdvigroup c cDVI MAROC hone 212 5 22 48 09 40 ax 212 5 22 48 34 69 DVI WEDEN hone 46 0 31 760 19
6. Press B to exit from programming mode The red LED lights off 2 beeps are emitted to confirm that the key pad is in stand by operating mode 4 times red LED flashing and 4 beeps emitted indicate a data computing error INSTALLATION MANUAL PROFIL100EINT Illuminated Mullion Weatherproof Keypad Self Contained F RESET MASTER CODE On stand by operating mode put a jumper on P2 The green LED lights on One beep is emitted Wait until the green LED switches off To desable the function remove the jumper The master code is restored to its default value 1 23 45 6 in 6 digits code 12345 in 5 digits code and 1 2 3 4 in 4 digits code G CHANGING THE CODE BY A USER To authorize a user to modify its own User code place the jumper on P3 to disable the function remove the jumper 1 Enter the old user code The relay is activated and a beep is emitted The green LED lights on One beep is emitted 2 Enter the 2 digits sub master code Relay 1 for the first use A and B Relay 2 for the first use 1 and 3 The red LED lights on A beep is emitted to authorise the modification 3 Enter the new user code The green LED lights on during 1 second 2 beeps are emitted to confirm the new code The red LED lights off 4 Check the new user code to be sure of the modification H SETTING A SUB MASTER CODE The Sub Master code allows the user to change its own code without entering in pr
7. conis es 64 CE Certification CE 1 oll G 25 C 70 C ARD12 BS60 2 RAPPELS ET RECOMMANDATIONS Rappel de c blage Faire attention bien isoler les fils non utilis s Montage Afin d optimiser la fixation du PROFIL1O0EINT et de pr venir les tentatives d arrachage privil giez les surfaces planes Recommandations d installation Pour s curiser l installation n oubliez pas de placer la varistance sur le syst me de verrouillage en parall le au niveau de l alimentation Composition des codes Par soucis de s curit veillez modifier le code ma tre usine par celui de votre choix Lors du changement du code maitre usine et de la cr ation des codes utilisateurs vitez les codes trop simples ex les suites 3 4 5 6 7 Alimentations Il existe deux alimentations adapt es pour le Digicode PROFIL100EINT ARD12 et BS60 Alimentation s par e pour les l ments de commande cdvi com cdvigroup com 11 AOOEINT i ps od r tro clair avec lectronique int gr 3 KIT DE MONTAGE PROFIL100EINT Varistance Cl male coud e Vis Diax 05D 680K pour vis Diax a t te frais e M5x8 1 1 1 4 MONTAGE Apr s avoir v rifi que le kit de montage est complet et op r le raccordement du clavier cod Digicode PROFIL100EINT vous allez pouvoir proc der l installation finale du produit R unissez le mat riel appropri Per euse tournevis
8. lors de la composition du code d ouverture aucun bip touche n est est possible d autoriser les bips audible Il touches en faisant comme suit Tapez 2 fois le code ma tre Pour la premi re utilisation le code ma tre usine est 12345 Deux bips sonores sont mis pour confirmer l entr e en programmation 2 Tapez AA Un bip est mis Tapez 0 pour supprimer les bips touches pendant la composition du code d ouverture Tapez 1 pour autoriser les bips touches pendant la composition du code d ouverture Un bip sonore est mis pour confirmer la programmation 3 Tapez B pour sortir de la programmation Deux bips sonores sont mis pour confirmer le retour au mode normal de fonctionnement Utilisation des leds rouges et vertes Les leds rouges et vertes sont pr vues pour accepter le 12 V DC r sistances int gr es Elles sont c bl es de la fa on suivante rs SrA Marron 2 2KQ O Led 12 V DC rr Rouge Blanc ov Vert 2 2KQ amp Led 12 V DC 74 Verte Jaune OW MANUEL D INSTALLATION PROFILI10OEINT aie Clavier cod r tro clair avec lectronique int gr EEE CU Ci joint un tableau r capitulatif qui vous servira indiquer le code attribu chaque utilisateur
9. m tre et suivez les recommandations de montage du PROFIL100EINT S C O S6S66cE 6 cdvi com 12 cdvigroup com Percer for t 5mm les 2 trous de fixation profondeur mini 35mm ainsi que l ouverture pour le passage du c ble lectrique Passer le c ble lectrique du PROFIL100EINT dans son ouverture Poser ensuite le Digicode contre son fond du haut vers le bas en L assemblant tout d abord avec le crochet sup rieur S 0 O O SESS66E 6 Positionner les 2 chevilles plastiques dans les trous Fixer le fond du PROFIL100EINT sur le support l aide des vis cruciforme a t tes frais es Fixer le Digicode avec son fond logement dans le bas du produit par l interm diaire de la vis Diax M5x8 et de leur outil sp cifique MANUEL D INSTALLATION PROFIL100EINT Clavier cod r tro clair avec lectronique int gr 5 SCHEMA DE RACCORDEMENTS INT1 Changement tides F fs de code par Switch de remise l utilisateur a zero de la m moire Placez Placez le Violet Switch sur ON le Switch sur ON Bleu clair Vert clair Vert fonc INTI INT2 Bleu fonc oo l gas Marron go Noir G che mission Alimentation 12 V 24 V AC 12 V 48 V DC 230 V Alimentation verrouillage Correspondances Alim
10. 30 ax 46 0 31 748 09 30 DVI K hone 44 0 1628 531300 ax 44 0 1628 531003 DIGIT FRANCE DCO 1000 T7 n Fax 33 0 1 41 71 06 86 Phone 33 0 1 41 71 06 85 drawing features and dimensions could be changed without prior notice it document photos dessins caract ristiques et c tes sont susceptibles sur le pr s alable LA G CHE LECTRIQUE FRANCE Phone 33 0 3 88 77 32 82 Fax 33 0 3 88 77 85 02
11. 50mA max En 24 V AC 40mA max des signaux sonores A Remise z ro de la m moire 1 Tapez 2 fois le code ma tre Pour la premi re utilisation le code ma tre usine est 12345 La Led rouge s allume Deux bips sonores sont mis confirment l entr e en programmation 2 Tapez A6 La led verte s allume 1 seconde Un bip sonore est mis Tapez A et B pour valider la remise z ro La led verte s allume Attendre qu elle s teigne Deux bips sonores sont mis Le code ma tre est de nouveau 12345 et tous les codes sont effac s Le clavier est r initialis les leds rouges restent allum es puis s teignent Le clavier est sorti de la programmation et les valeurs par d faut sont r tablies Vous avez aussi une seconde possibilit pour remettre z ro la m moire 1 Coupez l alimentation Basculez le switch INT2 sur ON 2 R tablir l alimentation La led verte s allume Attendre quelques secondes un bip est mis La led verte s teint cdvi com 14 cdvigroup com Basculez le switch INT2 sur OFF 3 Le code ma tre est de nouveau 12345 et tous les codes sont effac s Les Valeurs par d faut sont r tablies B Programmation du nombre de termes 1 Tapez 2 fois le code ma tre Pour la premi re utilisation le code ma tre usine est 12345 La led rouge s allume Deux bips sont mis pour confirmer l entr e en programmation 2 Tapez
12. 89 22 56 90 23 57 91 24 58 92 25 59 93 26 60 94 27 61 95 28 62 96 29 63 97 30 64 98 31 65 99 32 66 33 67 Relay 2 2 output Reminder From user location 00 to 99 Relay 1 From 00 to 59 cdvi com 10 cdvigroup com MANUEL D INSTALLATION PROFIL100EINT Clavier cod r tro clair avec lectronique int gr 1 PRESENTATION DU PRODUIT E R tro clair E Inox E 2 relais 1 relais d ouverture 1 contact RT 6A 250 V 1 relais d ouverture 1 contact RT 1A 120 V E Etroit Id al pour la pose sur profil Aluminium E Pr conis pour l activation et la d sactivation de votre syst me d alarme E Pose en applique E Free voltage E Montage avec vis Diax m 100 codes utilisateurs m Signalisation lumineuse et sonore m Dimensions L x x P 165 x 43 x 27 mm m Alimentation 12 V 24 V AC 12 V 48 V DC m Consommation de 25 80 mA m Clavier 13 touches lumineux m Sauvegarde m moire permanente E2PROM m 100 codes programmables en 4 5 ou 6 termes m Code maitre programmable en 4 5 ou 6 termes m 1 bouton poussoir de sortie commandant l ouverture m 1 touche pour l ouverture libre m Code maitre usine et raz des codes m Modification des codes par l utilisateur Tension libre HR CE AUTE R SISTAN RU VANDALISME 165 165 O MOO gt Q x DEEE amp RoHS Test brouillard salin its i Alimentations pr
13. A4 pour la saisie du nombre de termes des codes La led verte s allume 1 seconde Un bip est mis Tapez 4 5 ou 6 pour le nombre de termes La led verte s allume 1 seconde Deux bips sont mis pour confirmer la programmation 3 Tapez A5 pour changer le code ma tre La led verte s allume 1 seconde Un bip est mis Tapez les 4 5 ou 6 termes du nouveau code maitre La led verte s allume 1 seconde Un bip sonore est mis pour confirmer la programmation MANUEL D INSTALLATION PROFIL100EINT Clavier cod r tro clair avec lectronique int gr 4 Tapez B pour sortir de la programmation La led rouge s teint Deux bips sonore sont mis pour confirmer le retour au mode normal de fonctionnement Cas de figure Vous avez un code ma tre et des codes utilisateurs 5 termes Vous souhaitez utiliser des codes 4 termes Vous faites donc la d marche indiqu e ci dessus en modifiant le code ma tre Lorque le nombre de terme du code maitre est bien pass de 5 4 termes les codes utilisateurs deviennent simultan ment des codes 4 termes Ex Code maitre ou code utilisateur 12369 Passage 4 termes Tapez 2369 Code ma tre ou code utilisateur 12369 Passage 6 termes Tapez012369 Il est conseill de programmer les codes en 6 termes puis de modifier le nombre de termes C Programmation du code ma tre 1 Tapez 2 fois le code ma tre Pour la premi re ut
14. de commande en secondes 01 pour 1 seconde jusqu 99 pour 99 secondes La dur e 00 correspond au fonctionnement bistable du relais 2 La led verte s allume 1 seconde Un bip est mis pour confirmer la programmation cdvi com cdvigroup com 15 F 16 Pour sortir de la programmation tapez B La led rouge s teint Deux bips sont mis pour confirmer le retour au mode normal de fonctionnement 4 clignotements de la led rouge et 4 bips indique une erreur de saisie Remise a z ro du code maitre En fonctionnement normal basculez le switch INT2 sur ON La led verte s allume Un bip est mis Attendre que la led verte s teigne Basculez le switch INT2 sur OFF Le code maitre est de nouveau 123456 en 6 termes 1 2 3 4 5 en 5 termes ou 1 23 4 en 4 termes Changement du code d entr e par l utilisateur L autorisation de changement de code par l utilisateur est d termin e par le position nement du switch INT1 switch sur OFF pour interdire le changement de code 1 Composez le code utilis actuellement Le relais d ouverture est command La led verte s allume Un bip est mis 2 Tapez imm diatement les 2 termes du code de modification Relais 1 la premi re utilisation A et B Relais 2 la premi re utilisation 1 et 3 La led rouge s allume Un bip est mis pour autoriser le changement 3 Composez le nouveau code d ouverture La led verte s a
15. during 1 second One beep is emitted to confirm that the master code is programmed 3 Press B to exit from the programming mode The red LED lights off 2 beeps are emitted to confirm that the keypad is in stand by operating mode D ADDING CHANGING OR DELETING A USER CODE Group 1 From address 00 to address 59 relay output 1 Group 2 From address 60 to address 99 relay output 2 1 Enter the master code twice 12345 default value master code The red LED lights on 2 beeps are emitted to confirm entry in programming mode 2 To add a user code enter the user location from 00 to 99 If the user location is free the green LED lights on during 1 second and 1 beep is emitted enter the 4 5 or 6 digits User code If the user location is already programmed the red LED flashes 4 times 4 beeps are emitted Enter a new 4 5 or 6 digits code The green LED lights on during 1 second A beep is emitted to confirm the new user code 4 To delete a User code enter the user location 4 beeps are emitted Press 000000 in 6 digits length code or 00000 in 5 digits length code or 000 0 4 digits length code A beep is emitted to confirm the new user code cdvi com 6 cdvigroup com Mullion Weatherproof Keypad Self Contained NOTE If the Pin code is already programmed or is identical to the master code the red LED flashes 4 times then 4 beeps are emitted Press B to exit from the programming mode 2 b
16. eeps are emitted to confirm that the key pad is in stand by operating code E TIME OUTPUTS This section allows to program the illumination time and the Relay activation time 1 Enter the master code twice 1 23 45 default value master code The red LED lights off 2 beeps are emitted to confirm entry in programming mode 2 Press AO to program the key in keypad time and the keys lit time The green LED lights on during 1 second 1 beep is emitted Enter the time in 10th of second 10 for 10 seconds up to 99 for 99 seconds the backlighting dims 10 seconds after the last keypress or switches off after entering a valid code The green LED lights on during 1 second Press 00 for permanent illumination keys One beep is emitted to validate the time 3 Press A1 to program relay 1 output time door release time The green LED lights on during 1 second 1 beep is emitted For a latched output enter the time in seconds 01 for 1 second up to 99 for 99 seconds Press 00 for a toggled output The green LED lights on during 1 second One beep is emitted to validate the time 4 Press A2 to program relay 2 output time door release time The green LED lights on during 1 second 1 beep is emitted For a latched output enter the time in seconds 01 for 1 second up to 99 for 99 seconds Press 00 for a toggled output The green LED lights on during 1 second One beep is emitted to validate the time
17. entation 12 V 24 V AC ou 12 Va 48 V DC Rouge Alimentation 12 V 2 4V AC ou 12 Va 48 V DC Rose Bouton int rieur de sortie relais 1 Violet Commun Bleu clair Contact horloge H1 Bleu fonc Contact repos du relais 2 Vert fonc Commun du relais 2 Vert clair Contact travail du relais 2 Orange Contact repos du relais 1 Jaune Commun du relais 1 Marron Contact travail du relais 1 Blanc Sortie anti arrachement Gris Sortie anti arrachement Ce produit est livr avec une varistance Celle ci doit tre mont e directement sur les bornes de la g che ventouse moteur command e par l quipement Si l appareil fonctionne avec plusieurs g ches chacune doit tre quip e de varistance La varistance limite les surtensions provoqu es par le bobinage de la g che effet de self Dans le cas o la ventouse utilis e est du type Shear Lock celle ci doit tre aliment e par une alimentation ind pendante du PROFIL100EINT cdvi com cdvigroup com 13 OOEINT Les valeurs du PROFIL100EINT sont par d faut Sans codes Temporisation clairage 10 secondes Temporisation d ouverture pour tous les relais 1 seconde Nombre de termes 5 Code maitre usine 12345 Temporisation s curit programmation 120 secondes Termes de modification par utilisateur Version 1
18. hts off Remove P2 jumper 3 The master code is restored to its default value 12345 All the User codes are deleted from the keypad B SETTING CODE LENGTH 1 Enter the master code twice 1 23 45 default value master code The red LED lights on 2 beeps are emitted to confirm entry in programming mode 2 Press A4 to program the code length The green LED lights on during 1 second One beep is emitted Press 4 5 OR 6 for the digit code The green LED lights on during 1 second Two beeps are emitted to confirm programming of the code length 3 Press A5 to modify the master code The green LED lights on during 1 second One beep is emitted Enter the new 4 5 or 6 digits master code The green LED lights on during 1 second One beep is emitted to confirm programming of the new master code 4 Press B to exit from programming mode 2 beeps are emitted to confirm that the key pad is in stand by operating mode 4 beeps indicate a data computing error cdvi com cdvigroup com 5 OOEINT C CHANGING THE MASTER CODE The master code is used only to enter in programming mode 1 Enter the master code twice 1 23 45 default value master code The red LED lights on 2 beeps are emitted to confirm entry in programming mode 2 Press A5 to modify the master code The green LED lights on during 1 second One beep is emitted Enter the new 4 5 or 6 digits master code The green LED lights on
19. ilisation le code ma tre usine est 12345 La led rouge s allume Deux bips sonore sont mis pour confirmer l entr e en programmation 2 Tapez A5 La led verte s allume 1 seconde Un bip est mis Tapez les 4 5 ou 6 termes du nouveau code maitre La led verte s allume 1 seconde Un bip est mis pour confirmer la programmation 3 Tapez B pour sortir de la programmation La led rouge s teint Deux bips sont mis pour confirmer le retour au mode normal de fonctionnement D Programmation des codes Relais 1 Groupe 1 Du rang 00 au rang 59 Relais 2 Groupe 2 Du rang 60 au rang 99 Pour programmer des codes Code maitre Code maitre Led rouge gt P allum e 1 Tapez 2 fois le code maitre Pour la premi re utilisation le code maitre usine est 12345 La led rouge s allume Deux bips sonore sont mis pour confirmer l entr e en programmation 2 Tapez le n du rang programmer de 00 99 Si le rang est libre la led verte s allume 1 seconde tapez les 4 5 ou 6 termes du code Si le rang est occup la led rouge clignote 4 fois Et quatre bips sont mis Tapez les 4 5 ou 6 termes du code ou tapez 0000000100000010000 pour annuler le code existant La led verte s allume 1 seconde Un bip est mis pour confirmer la programmation Si le code entr correspond un code existant ou s il est identiq
20. llion Weatherproof Keypad Self Contained SC Sub master Sub master Buzzer audible User codes code 1 code 2 feedback A6 A7 A8 AA 00 99 The gren LED lights on during 1 sec The gren LED lights on during 1 sec The gren LED lights on during 1 sec 1 x beep The gren LED lights on during 1 sec 1 x beep 1 x beep 1 x beep 4 5 or 6 digit code 1 x beep 0 buzzer 2 digits 2 digits disabled AB Default 13 Default Press A then B 1 buzzer 4 beeps enabled user location used 1 beep user location free 1 x beep OK 1 x beep OK 4 beeps ERROR 4 beeps ERROR 2 x beeps OK 1 x beep OK 4 beeps ERROR Press B to exit from programming 1 x beep OK 2 beeps cdvi com cdvigroup com 9 JN MANUAL 100EIN ted Mullion Weatherproof Keypad Self Contained This spread sheet will help you keep track of the user codes programmed in the keypad ee Code Name Pr Code Name Seaton Name 00 34 68 01 35 69 02 36 70 03 37 71 04 38 72 05 39 73 06 40 74 07 41 75 08 42 76 09 43 717 10 44 78 11 45 79 12 46 80 13 47 81 14 48 82 15 49 83 16 50 84 17 51 85 18 52 86 19 53 87 20 54 88 21 55
21. llume 1 seconde Deux bips sont mis confirmant la validation du nouveau code et le retour un fonctionnement normal La led rouge s teint 4 V rifiez la m morisation du nouveau code en le composant Programmation des termes de modifications 1 Tapez 2 fois le code ma tre Pour la premi re utilisation le code ma tre usine est 12345 La led rouge s allume Deux bips sont mis pour confirmer l entr e en programmation 2 Tapez A7 pour la saisie des termes de modifications des codes utilisateurs du groupe 1 La led verte s allume 1 seconde Un bip est mis Tapez les deux termes de modifications La led verte s allume 1 seconde cdvi com cdvigroup com od r tro clair avec lectronique int gr Un second bip est mis pour confirmer la programmation 3 Tapez A8 pour la saisie des termes de modifications des codes utilisateurs du groupe 2 La led verte s allume 1 seconde Un bip est mis Tapez les deux termes de modifications La led verte s allume 1 seconde Un second bip est mis pour confirmer la programmation 4 Tapez B pour sortir de la programmation La led rouge s teint Deux bips sont mis pour confirmer le retour au mode normal de fonctionnement Programmation du signal sonore Le signal sonore est toujours audible en pro grammation Il en est de m me lors de la com mande d ouverture suite la reconnaissance d un code Par d faut
22. nts When selecting a master code and user code avoid simple codes Mounting recommendations Examplen 3 89 6 2 Mount the keypad on a flat surface to avoid any vandalism and to insure the best mounting Back EMF protection To secure the system from back electromagnetic Wiring reminder fields do not forget to mount the varistor Make sure to insulate any unused wires in parallel on the lock cdvi com 2 cdvigroup com INSTALLATION MANUAL PROFIL1O0OEINT Illuminated Mullion Weatherproof Keypad Self Contained 3 MOUNTING KIT Diax screws M5x8 Varistor T20 Diax Spanner PROFIL100EINT 1 1 1 4 MOUNTING INSTRUCTIONS Once you have made sure that the mounting kit is complete and that you prepared the cables of the Digicode PROFILIOOEINT encoded keypad you can proceed and mount the product Make sure that you have all the appropriate tools drill screw drivers and a meter tape and follow the mounting instructions for the PROFIL1OOEINT S S a O SESCEE 6 Place the back plate of the PROFIL100EINT on the wall then mark with a pen the hole location then drill the 2 mounting holes drill bit 5mm a nd 35mm hole depth and the hole wiring access Insert the cable in the hole access area of the back plate Then mount the keypad on the back plate placing first the top in the hooks and then the bottom OIOI CIOICIOICIOE 6e
23. ogramming mode For security reasons the code need to be changed periodically This feature makes it easier and faster to change its code 1 Enter the master code twice 1 23 45 default value master code The red LED lights on 2 beeps are emitted to confirm entry in programming mode 2 Press A7 to program a sub master code for the user individual Pin code modification The green LED lights on during 1 second One beep is emitted Enter the new 2 digits sub master code The green LED lights on during 1 second One beep is emitted to confirm programming of the sub master code 3 Press A8 to program a sub master code for the user individual Pin code modification The green LED lights on during 1 second One beep is emitted Enter the new 2 digits sub master code The green LED lights on during 1 second One beep is emitted to confirm programming of the sub master code 4 Press B to exit from the programming mode The red LED lights off 2 beeps are emitted to confirm that the keypad is in stand by operating mode Audible Feedback The audible signal is enabled in programming mode and when the relay is energised after a valid code To enable the audible feedback on a key press 1 Enter the master code twice 1 23 45 default value master code 2 beeps are emitted to confirm entry in programming mode 2 Press AA One beep is emitted Press O to disable the audible signal during a keypre
24. relais Groupe 1 A et B Version 2 relais Groupe 2 1 et 3 Un bip est mis lors de la mise sous tension Lors de la programmation certaines manipulations ont comme cons quences d r tro clair avec lectronique int gr 1 bip court Mise sous tension 1 bip long Validation d une saisie en programmation ou ouverture autoris e 2 bips courts Entr e ou sortie de programmation 4 bips courts Erreur de saisie Termes utilis s et codes d ouverture Toutes les touches du clavier sont autoris es pour composer les codes Le code maitre et les codes d ouverture de porte doivent tre compos s de 4 5 ou 6 termes Le code ma tre ne peut pas tre utilis comme code d ouverture Les codes 000000 ou000000u0000 servent a annuler un code existant et ne peuvent donc pas servir comme code d ouverture de porte Commande par bouton poussoir Le raccordement du bouton poussoir P1 est pr vu pour commander le relais 1 le mode et la temporisation sont programmables Le contact horloge H1 permet l utilisation de la touche Clef comme bouton ext rieur Si le contact horloge est ouvert la touche Clef est inactive Si le contact horloge est ferm la touche Clef est utilis e pour l ouverture libre Consommation Avec les 2 relais command s et l clairage permanent En 12 V DC 90mA max En 12 V AC 70mA max En 24 V DC
25. ss Press 1 to enable the audible signal during a keypress One beep confirms the new setting Press B to exit from programming 2 beeps are emitted to confirm exit from programming mode Use of the red and green LEDs The red and green LEDs are designed to receive 12V dc built in resistors They are wired as follows Brown 12V dc 2 2KQ Red lA LED NE Green LED White O ov Green 9 12V dc 2 2KQ Yellow cdvi com cdvigroup com 7 IL10 INT ed Mullion Weatherproof Keypad Self Contained Enter Master code twice Illumination duration AO Al A2 Code length A4 Master code A5 The gren LED lights on during 1 sec 1 x beep 10 99 sec 00 permanent 01 Default 1 x beep OK 4 beeps ERROR The gren LED lights on during 1 sec 1 x beep 01 99 sec 00 toggled 01 Default 1 x beep OK 4 beeps ERROR The gren LED lights on during 1 sec 1 x beep 01 99 sec 00 toggled 01 Default 1 x beep OK 4 beeps ERROR The gren LED lights on during 1 sec 1 x beep 4 5 or 6 digits 5 Default 1 x beep OK 4 beeps ERROR The gren LED lights on during 1 sec 1 x beep Change master code 12345 D faut 1 x beep OK 4 beeps ERROR 8 cdvi com cdvigroup com INSTALLATION MANUAL PROFIL100EINT Illuminated Mu
26. ue au code ma tre la led rouge clignote 4 fois pour indiquer une erreur Quatre bips sont mis en cas d erreur Les codes 000000000000 ou 0 0 0 0 servent annuler un code existant et ne peuvent donc pas servir comme code d ouverture de porte 3 Tapez B pour sortir de la programmation La led rouge s teint Deux bips sont mis pour confirmer le retour au mode normal de fonctionnement E Programmation des temporisations 1 Tapez 2 fois le code ma tre Pour la premi re utilisation le code ma tre usine est 12345 La led rouge s allume Deux bips sont mis pour confirmer l entr e en programmation 2 Tapez AO pour la temporisation du clavier La led verte s allume 1 seconde Un bip est mis Tapez la dur e de commande en secondes 10 pour 10 secondes 99 pour 99 secondes ou ta pez 00 pour obtenir un clairage permanent La led verte s allume 1 seconde Un bip est mis pour confirmer la programmation 3 Tapez A1 pour la temporisation du relais 1 La led verte s allume 1 seconde Un bip sonore est mis Tapez la dur e de commande en secondes 01 pour 1 seconde jusqu 99 pour 99 secondes La dur e 00 correspond au fonctionnement bistable du relais 1 La led verte s allume 1 seconde Un bip sonore est mis pour confirmer la programmation 4 Tapez A2 pour la temporisation du relais 2 La led verte s allume 1 seconde Un bip est mis Tapez la dur e
27. ust be equipped with a varistor The varistor prevents voltage electromagnetic lock is used it must be connected to a separate power supply from the PROFIL100EINT 4 cdvi com cdvigroup com surges caused by the coil of the strike self effect If the shear lock type of INSTALLATION MANUAL PROFIL100EINT Illuminated Mullion Weatherproof Keypad Self Contained ER 2 short beeps Enter or Exit from programming 4 short beeps Default values Without codes Illumination time 10 seconds Control by exit push button The connection of push button P1 is intended to control relay 1 Relay release time 1 second Code length 5 digits Master Code 12345 Programming security time 120 secondes Code length for sub master code in length m Version 1 relay Group 1 AandB All the keypad keys can be used to program a code The master code and the Pin code can be of 4 5 or 6 digits code m Version 2 relays Group 2 1 and 3 Audible signal Data computing error Code length The master code and the User codes can be of 4 or 5 digits the mode and the timer are programmable The clock switch H1 allows the Key key to be used as an outdoor button If the clock switch is open the Key key is inactive If the clock switch is closed the Key key is used for free unlocking The buzzer indicates different audible The master code CAN NOT

Download Pdf Manuals

image

Related Search

PROFIL100EINT

Related Contents

MIC Series 550 Camera - Bosch Security Systems  USER'S MANUAL TECSUN DR-920 DIAGRAM - BCL  Husqvarna 917.377231 Lawn Mower User Manual  DIGITAL 124 Limited Edition 2008  【初公開】初心者がネットビジネスを あっという間にマスターする方法  Documents_files/Le conducteur mode d`emploi  Emerson CSB400 Data Sheet  基本 CMYK - TerraTekIntl  AA - TopsCCC  Edsal RR31318 Instructions / Assembly  