GENERALAire RESIDENTIAL AIR TREATMENT PRODUCTS
Contents
1. GENFRALA L re RESIDENTIAL AIR TREATMENT PRODUCTS 1 ELECTRONIC TEMPERATURE COMPENSATING HUMIDISTAT 4 NORMAL wub 5 ZA 2 N _ 1 HUMIDITY CURVE ELECTRONIC TEMPERATURE SEE OWNERS MANUAL El COMPENSATING HUMIDISTAT N INSTALLER PLEASE FILL OUT AND MAIL WARRANTY CARD AFTER INSTALLATION IS COMPLETE LEAVE OWNERS MANUAL WITH HOME OWNER SAFETY WARNING Improper electrical wiring can result in fire failure or loss of humidity control Disconnect electrical power before installing and servicing Failure to disconnect electrical power may result in injury or death All local building and electrical codes must be followed The E1 must be installed by a qualified Technician Failure to properly install the E1 may result in property damage or personal injury Homeowners must read instructions and understand the operation of the E1 and the humidifier s it controls Improper operation can result in over or under humidification Over humidification can result in condensation structural damage and mold Condensation within a building s structure can cause loss of structural strength Condensation can also enable mold and mildew growth resulting in personal injury and damage to building structure and contents Safety questions regarding the E1 may be directed to General Filters Inc ll APPLICATION The E1 Electronic Humidistat provides automatic low voltage con
2. MODE AUTO R GLAGES DE BASE R glez le bouton de commande 5 r glage convient la plupart des maisons construites apr s 1965 Si votre maison est plus ancienne si vous y d celez de la condensation ou que vous soup onnez que de la condensation s y forme voir les R glages suppl mentaires Dans les cas o un taux d humidit plus lev est souhait voir les R glages suppl mentaires MODE AUTO R GLAGES SUPPL MENTAIRES L air humide se condense au contact d une surface froide Vous pouvez observer ce ph nom ne sur le miroir de la salle de bain apr s une douche chaude ou la cuisine lorsque vous faites bouillir de l eau La condensation r sulte de la combinaison d un taux d humidit lev et d une faible temp rature La r sistance d une habitation la condensation d pend de la r gulation de la qualit de l air et de l infiltration de vapeur Plus la qualit de l isolation des pare vapeur et des parois tanches l infiltration est lev e plus le taux d humidit peut tre lev sans risque de condensation Votre humidistat 1 est con u pour emp cher la condensation sur les fen tres ext rieures et l int rieur des murs ext rieurs en diminuant le taux d humidit l int rieur pour compenser toute diminution de la temp rature l ext rieur Le E1 fait appel une courbe d humidit que vous choisissez pour r gler les taux d humidit l int rieur selon le type d habitation La cour
3. The installer must be a qualified Technician Disconnect electrical power before beginning installation Do not install the humidistat on the warm air duct The foam gasket is used for mounting on a return duct only Conduct a thorough checkout before leaving the installation WALL MOUNTING INSTRUCTIONS 1 Chose a location for the E1 about five feet above the floor on an inside wall with average room temperature and relative humidity conditions 2 Drill a small hole in the wall and run low voltage wiring to the location chosen Pull about 6 of wire through the hole Plug the opening to prevent drafts from affecting the humidistat operation 3 Remove the knob and housing from the base by prying with a small screwdriver at the notch in the side of the housing Copy serial number located on housing back onto the warranty registration 4 Mount the base horizontally over the wires Attach directly to the wall using four screws provided 5 Connect wires to screw terminals on the control assembly as shown in DIAGRAM 1 2 3 4 5 Replace housing and knob OWNERS MANUAL MOUNTING ON THE RETURN AIR DUCT 2 Do not install the humidistat on the warm air duct 1 Locate the humidistat at least 24 upstream of the humidifier or bypass on the return air duct Avoid areas of direct radiation like secondary heat exchangers in the fan compartment 2 Place template using level Cut sensor hole as shown on template Drill four 3 32 hol
4. walls and ceiling no vapor barrier 3 4 Average home built between 1950 and 1965 use of R6 2 insulation in walls and ceiling no vapor barrier 4 5 Average home built after 1965 use of R11 3 1 2 insulation in walls and ceiling with kraft vapor barrier Average home built after 1980 use of R11 3 1 2 insulation in 5 6 walls and R19 6 in ceiling with kraft vapor barrier Styrofoam insulation on exterior 1 min Double pane windows Top quality home built after 1990 use of R19 6 insulation in 6 7 walls and R38 12 in ceiling with interior poly vapor barrier Styrofoam insulation on exterior 2 min Triple pane windows IF YOU ARE UNSURE OF YOUR HOME S CONSTRUCTION Set the control knob at 5 lower 1 2 graduation until condensation stops If condensation occurs turn the control knob CAN 27 1 L re RESIDENTIAL AIR TREATMENT PRODUCTS 1 ELECTRONIC TEMPERATURE COMPENSATING HUMIDISTAT TABLE OF IDEAL HUMIDITIES NOTE Humidifier shuts off above 50F 10 C OUTDOOR TEMPERATURE 20 10F OF 10F 207 307 40 50F 29 C 23 C 18 C 12 C 7 1 4 10 30 35 40 45 45 45 45 KNOB POSITION 25 30 35 40 45 45 45 20 25 30 35 40 45 45 15 40 30 45 35 3 10 10 15 20 25 30 35 40 2 10 10 10 15 20 25 30 35 1 10 10 10 10 15 20 25 30 III INSTALLATION INSTRUCTIONS PRECAUTIONS
5. INSTALLATION 50 F 10 C 18 000 DE CE PRODUIT OU L USAGE QUI EN EST FAIT SAUF TEL QU NONC DANS LA 77 F 25 10 000 PRESENTE GARANTIE LIMITEE LE FABRICANT DECLINE TOUTE RESPONSABILITE POUR FORMULAIRE N E1 07 DOSSIER 13125 LES DOMMAGES INDIRECTS OU CONS CUTIFS La pr sente garantie limit e vous conf re des droits donn s qui sont reconnus par la loi Vous pouvez aussi jouir d autres droits qui varient d une province ou d un tat l autre Certaines provinces et certains tats n autorisent pas les limitations sur les garanties tacites ou les exclusions de dommages indirects ou cons cutifs l avis de limitation et d exclusion qui pr c de peut donc ne pas s appliquer vous Toute question concernant la pr sente garantie limit e doit tre adress e au fabricant Aux tats Units seulement le fabricant a choisi de ne pas participer au syst me de r glement l amiable pr vu par le Magnuson Moss Warranty Act GENERAL FILTERS INC 43800 GRAND RIVER AVE NOVI MICHIGAN 48375 1115 CANADIAN GENERAL FILTERS LTD 39 CROCKFORD BLVD SCARBOROUGH ONTARIO M1R3B7 Lithographie faite aux tats Unis WWW GENERALAIRE COM WWW CGFPRODUCTS COM 5 T 28 He Og 5389 cogs o o S Q so sao 2 EH TE ne gt 20e 8 A 95r LD A O O isn lt O O r D 5 H Pum S 2 lt 2 wg co m V 5 LU N gt lt 9
6. SH311Id4 1VH3N35S Please Fold and Tape LE PROPRI TAIRE DOIT REMPLIR LA CARTE D ENREGISTREMENT et accessoires purificateurs 9J8H FUEL OIL FILTERS AND ACCESSORIES Filtres mazout DIGITAL HUMIDITY GAGE Hygrom tre num rique Air CLEANERS AND AIR PURIFIERS Filtres air et Air FILTER GAGE Indicateur pour filtre air FILL OUT THIS LITERATURE REQUEST FORM HUMIDIFIERS Humidificateurs FORM NO E1 07 FILE 13125 Rev Litho in U S A e GENERALA L re RESIDENTIAL AIR TREATMENT PRODUCTS 1 HUMIDISTAT LECTRONIQUE COMPENSATION THERMIQUE 4 NORMAL HUMIDITY CURVE EL IC TEMPERATURE SEE OWNERS MANUAL COMPENSATING HUMIDISTAT N AVIS L INSTALLATEUR VEUILLEZ RETOURNER PAR LA POSTE LE BON DE GARANTIE DUEMENT REMPLI UNE FOIS L INSTALLATION TERMINEE REMETTEZ LE MANUEL D UTILISATION AU PROPRIETAIRE DE L HABITATION I S CURIT ATTENTION AVERTISSEMENT Toute erreur de c blage peut entra ner un incendie ou la d faillance du syst me de r gulation de l humidit Coupez le courant avant de proc der l installation ou l entretien de cet appareil Ne pas couper le courant peut entra ner des blessures voire la mort Tous les codes du b timent et les codes de l lectricit locaux doivent tre respect s Le E1 doit tre install par un technicien comp tent Si le E1 n est pas install convenablement cela pe
7. a lieu utilisez des tuyaux en cuivre 3 Infiltration d air excessive Colmatez toutes les fuites d air 4 Humidificateur sous dimensionn Passez une alimentation eau chaude s il y a lieu utilisez des tuyaux en cuivre Installez des humidificateurs suppl mentaires ou remplacez l appareil en place par un mod le plus puissant D PANNAGE suite TABLEAU 1 TEMP RATURE R SISTANCE EXT RIEURE OHMS GARANTIE LIMITEE 20 F 29 C 105 400 Le pr sent humidistat s il est enregistr comme il convient c est dire en retournant le bon de garantie ci joint d ment rempli General Filters Inc est garanti aux consommateurs contre tout 10 F 23 78 300 vice de mat riaux ou de fabrication et ce pendant duex p riode d un ann es compter de la 0 F 18 61 500 date d installation Toute pi ce d fectueuse sera r par e gratuitement sauf les frais de d montage de r installation et de transport Pour r clamer une r paration au titre de la pr sente 10 F 12 C 46 500 garantie limit e le consommateur doit exp dier la pi ce d fectueuse ou l humidistat au complet 20 F 7 37 100 au fabricant AUCUNE GARANTIE EXPRESSE AUTRE QUE CELLE QUI APPARAIT CI DESSUS N EST 30 F 1 28 500 OFFERTE POUR L HUMIDISTAT EN QUESTION LA DUR E DE TOUTE GARANTIE TACITE 40 F 4TC 23 000 DE VALEUR MARCHANDE OU D ADAPTATION A UN USAGE PARTICULIER EST LIMITEE UN ANNEE LE FABRICANT DECLINE TOUTE RESPONSABILITE LIEE A L
8. compris les vents de s cheuse 7 Si un capteur de temp rature ext rieure est fix l int rieur d une prise d air frais assurez vous que la sonde n est pas pos e plus d un pieds de la paroi externe de l habitation L humidificateur 1 Le module de commande actionnera l humidificateur tant que le taux d humidit l int rieur de l habitation ne d passe pas le fonctionne point de consigne sp cifi par le bouton de r glage sans arr t r 2 Mettez l appareil en mode TEST V rifiez que l humidificateur fonctionne 1 minute puis s arr te 3 Mesurez la r sistance du capteur de temp rature ext rieure s il y a lieu en d branchant les fils du capteur des bornes Mesurez la r sistance entre les fils au moyen d un ohm tre Comparez les valeurs mesur es celles qui figurent au TABLEAU 1 4 Le capteur de temp rature ext rieure ne doit pas tre fix sur un mur orient vers le Sud ni expos la lumi re directe du soleil 5 Le capteur de temp rature ext rieure ne doit pas tre install moins de 4 pieds des vents y compris les vents de s cheuse 6 Si un capteur de temp rature ext rieure est fix l int rieur d une prise d air frais assurez vous que la sonde n est pas pos e plus d un pied de la paroi externe de l habitation 7 D branchez les fils des bornes OUT Si l humidificateur continue de fonctionner inspectez le robinet lectromagn tique L humidificateur 1 R glez le thermostat d
9. tension 5 Le capteur de temp rature ext rieure doit tre situ au moins 6 po au dessus de la limite pr vue des neiges C BLAGE ATTENTION AVERTISSEMENT Coupez le courant avant de proc der l installation Le courant 120 volts peut causer des blessures voire la mort Voir les SCHEMAS DE C BLAGE 1 2 3 4 ou 5 TOUT LE C BLAGE DOIT TRE CONFORME AUX CODES DU B TIMENT LOCAUX CONTR LES V rifiez que les DEL vertes luisent Tournez le bouton de l humidistat en position TEST pendant que l appareil de chauffage fonctionne V rifiez que l humidificateur fonctionne effectivement 1 minute avant de s arr ter IV R GLAGES ATTENTION AVERTISSEMENT Ne r glez pas le taux d humidit relative une valeur excessive par temps froids L exc s d humidit peut provoquer de la condensation la fissuration et la moisissure La condensation l int rieur d une habitation peut causer des pertes de r sistance de la structure La condensation peut aussi favoriser la croissance de la moisissure entra nant des l sions et en endommageant l habitation et son contenu Consultez la section sur les MODES DE FONCTIONNEMENT pour savoir quels r glages conviennent CAVALIER INSTALL CAVALIER DE SELECTION DU MODE LE DEPLACER VERS LA DROITE POUR LE MODE MANUEL AUTO MAN CAPTEUR DE TEMP EXT MODE AUTOMATIQUE IL N EST PAS UTILIS EN MODE MANUEL ROBINET ELECTROMAGNETIQUE DE L HUMID
10. AGRAM 3 DIAGRAM 4 DIAGRAM 5 ALL WIRING SHOULD COMPLY WITH LOCAL ELECTRICAL CODES CHECKOUT Check that L E D glows green With furnace in operation turn humidistat to TEST position Observe that the humidifier operates for one minute then shuts off IV SETTINGS WARNING Do not set relative humidity too high during cold weather Over humidification can result in condensation structural damage and mold Condensation within a building s structure can cause loss of structural strength Condensation can also enable mold and mildew growth resulting in personal injury and damage to building structure and contents Refer to OPERATING MODES for proper settings WIRING DIAGRAMS DIAGRAM 1 WIRING 24V BYPASS HUMIDIFIER JUMPER WIRE INSTALLED MODE SELECTION JUMPER MOVE TO RIGHT FOR MANUAL MODE o o AUTO MAN AUTO MODE OUTDOOR TEMP SENSOR HUMIDIFIER 24V SOLENOID VALVE OR 24V DRUM MOTOR 727 58 24 V TRANSFORMER OMIT IF POWER SUPPLY m IS 20 30 VAC 120V POWER SUPPLY SWITCHED WITH FURNACE OPERATION ELECTRONIC TEMPERATURE COMPENSATING HUMIDISTAT E1 WIRING DIAGRAMS Continued DIAGRAM 2 WIRING 120V BYPASS HUMIDIFIER MODE SELECTION JUMPER MOVE TO RIGHT FOR MANUAL MODE o AUTO MAN JUMPER WIRE INSTALLED HUMIDIFIER 120V SOLENOID VALVE OR 120V DRUM MOTOR FIELD SUPPLIED RELAY 24 V COIL N O 5A MIN 24 V TRANSFOR
11. ATEUR EN USINE SCH MA 3 C BLAGE DE L HUMIDIFICATEUR DE PUISSANCE 1137 120 VOLTS CAVALIER RETIR _ CAVALIER DE SELECTION DU MODE LE DEPLACER VERS LA DROITE POUR LE MODE MANUEL Soe o o 24 V SORTIE CAPTEUR AUTO MAN SCHEMA 5 HUMIDIFICATEUR A INJECTION DE VAPEUR ELITE AVEC CABLAGE DE 230 V CAPTEUR DE TEMP EXT MODE AUTOMATIQUE z CAVALIER DE S LECTION DU MODE LE D PLACER IL N EST PAS UTILISE EN MODE MANUEL CAVALIER RETIRE VERS LA DROITE POUR LE MODE MANUEL 666666 gt FILS DE COMMANDE DE L HUMIDIFICATEUR CAPTEUR DE EXT MODE AUTOMATIQUE 727 58 IL N EST PAS UTILIS EN MODE MANUEL TRANSFORMATEUR 24 V 20 30 VCA L HUMIDIFICATEUR G A INJECTION DE VAPEUR ALIMENTATION DE 120 V FOURNIE LORSQUE LA FOURNAISE FONCTIONNE CAVALIER INSTALL l ser o o EN USINE GENERALA ire EE MANUEL D UTILISATION 1 HUMIDISTAT LECTRONIQUE A CONPENSATION THERMIQUE D PANNAGE AU MOYEN DES DEL COULEUR FONCTION Vert Les raccordements de l alimentation et du capteur sont bien faits Vert clignotant Les raccordements sont bien faits l humidistat est en mode TEST Rouge Erreur de c blage teinte D faillance de l alimentation du module de commande D PANNAGE SYMPT ME PROC DURE DE DIAGNOSTIC L humidificateur 1 V rifiez la tension aux bornes 24 V du module de commande de l humidificateur La lecture de tension devrait tre stable et se s
12. ED TEMPERATURE SETTING 20F 29 C 15 10F 23 20 OF 18 25 10F 12 30 20F 7 35 30F 1 40 AUTO MODE BASIC OPERATION Set the control knob at 5 This setting is suitable for most homes built after 1965 If your home was built before 1965 you see condensation or suspect condensation may occur see Advanced Operation For higher humidity requirements see Advanced Operation AUTO MODE ADVANCED OPERATION Moist air condenses on cold surfaces You may experience this on a bathroom mirror after a hot shower or in the kitchen when boiling water Condensation is caused by the combination of low temperature and high humidity A home s ability to resist condensation depends on the control of air and vapor infiltration The higher the quality of insulation infiltration barriers and vapor barriers the higher the humidity may be without condensation Your E1 humidistat is designed to prevent condensation on exterior windows and within exterior walls by lowering indoor humidity to compensate for lower outside temperatures The E1 uses a Humidity Curve you select to adjust the indoor humidity levels to your home s construction The Humidity Curve contains the proper humidity for every outdoor temperature Use the following Construction Qualifications to select the correct Humidity Curve RECOMMENDED HUMIDITY CURVE CONSTRUCTION QUALIFICATIONS Average home built before 1950 little or no insulation in 2 3
13. G OZ S m ES ow g g lt 6 5 25 NA 5 D LN lt wee lt D 95 5 ST on Zeaq 2 Z lt 0 9 Q as va LL O e D gt 2 3 de SEGE SES 5 5 Zu Z Oz o lt OF 2 0 lt 05 A
14. IFICATEUR 24 V OU MOTEUR TAMBOUR 24 V TRANSFORMATEUR 24 VOLTS OMETTRE SI L ALIMENTATION EST DE 20 30 V ALIMENTATION DE 120 V FOURNI LORSQUE LA FOURNAISE FONCTIONNE GENERAL A ire EXE MANUEL D UTILISATION 1 HUMIDISTAT LECTRONIQUE A CONPENSATION THERMIQUE SCH MA DES C BLAGE suite 2 DE L HUMIDIFICATEUR DE DERIVATION 120V CAVALIER DE S LECTION DU MODE LE D PLACER VERS LA DROITE POUR LE MODE MANUEL AUTO MAN CAPTEUR DE TEMP EXT MODE AUTOMATIQUE IL N EST PAS UTILIS EN MODE MANUEL SCHEMA 4 HUMIDIFICATEUR INJECTION DE VAPEUR ELITE AVEC CABLAGE DE 230 V CAVALIER INSTALL CAVALIER DE SELECTION DU MODE LE D PLACER VERS LA DROITE POUR LE MODE MANUEL ROBINET 56599909 LECTROMAGN TIQUE N E a AUTO MAN DE L HUMIDIFICATEUR 120 V Poy RELAIS FOURNI PAR L UTILISATEUR 24 V SERPENTIN N O DE pt OU MOTEUR TAMBOUR 120 V CAPTEUR DE TEMP EXT MODE AUTOMATIQUE IL N EST PAS UTILISE EN MODE MANUEL TRANSFORMATEUR 24 V 20 a 30 VCA MODULE DE COMMANDE DE L HUMIDIFICATEUR VERS LE VENTILATEUR L A INJECTION 120V 60 Hz RELAIS UNIDIRECTIONNEL DE VAPEUR A TROIS POLES FOURNI PAR SOUSTENSION L UTILISATEUR OMETTRE SI L ALIMENTATION EST ACTIV E PAR LES PRESSOSTAT U R DE LA FOURNAISE 12500 MARCHE ARR T CAVALIER DE L ALIMENTATION INSTALL DU VENTIL
15. IQUE TABLEAU HUMIDIT S ID ALES N B L humidificateur s teint au dessus de 50 F 10 TEMP RATURE EXT RIEURE 20 F 10 F OF 10F 20F 30 40F 50 29 C 23C 18C 12C 7C 1 4 10 C 25 30 35 40 45 45 45 45 POSITION DU BOUTON 20 25 30 35 40 45 45 45 20 25 30 35 40 15 45 45 10 15 20 25 35 40 45 3 10 10 15 20 25 30 35 40 2 10 10 10 15 20 25 30 35 1 10 10 10 10 15 20 25 30 D INSTALLATION PRECAUTIONS L installation doit tre effectu e par un technicien competent Coupez le courant avant de proc der l installation N installez pas l humidistat dans un conduit d air chaud La garniture en mousse sert uniquement fixer l humidistat dans un conduit de reprise d air Inspectez la zone de travail fond avant de quitter les lieux apr s avoir termin l installation DIRECTIVES POUR FIXER L APPAREIL AU MUR 1 Choisissez un emplacement pour le 1 sur une paroi int rieure qui se trouve au moins cinq pieds au dessus du sol et o r gne une temp rature et un taux d humidit relative moyenne par rapport aux conditions dans la salle 2 Percez un petit trou dans le mur et amenez un c ble basse tension jusqu l emplacement choisi Tirez sur le c ble jusqu ce qu environ 6 po de fil d passent du trou Rebouchez le trou pour viter que les courants d
16. MER 20 30 volts A C C HOT 60CY OMIT IF POWER SUPPLY IS SWITCHED WITH 12500 AIR PRESSURE ON OFF FURNACE CYCLE SWITCH SWITCH DIAGRAM 3 WIRING 120V 1137 POWER HUMIDIFIER JUMPER WIRE REMOVED 556 24 V OUT sensor MODE SELECTION JUMPER MOVE TO RIGHT FOR MANUAL MODE o AUTO MAN AUTO MODE OUTDOOR TEMP SENSOR NOT USED IN MANUAL MODE HUMIDIFIER CONTROL LEADS ee 727 58 24 V TRANSFORMER 20 30 VAC 120V POWER SUPPLY SWITCHED WITH FURNACE OPERATION 3 DIAGRAM 4 WIRING 230V ELITE DUCT STEAM HUMIDIFIER JUMPER WIRE INSTALLED MODE SELECTION JUMPER MOVE TO RIGHT FOR MANUAL MODE lo AUTO MAN AUTO MODE OUTDOOR SENSOR NOT USED IN MANUAL MODE TOTAN STEAM HUMIDIFIER CONTROL MODULE FIELD SUPPLIED 2 POLE SINGLE THROW RELAY FACTORY VR INSTALLED JUMPER FROM FAN POWER SUPPLY 12500 AIR PRESSURE SWITCH DIAGRAM 5 WIRING 230V ELITE ROOM STEAM HUMIDIFIER JUMPER WIRE REMOVED MODE SELECTION JUMPER MOVE TO RIGHT FOR MANUAL MODE 24V OUT sensor AUTO MAN AUTO MODE OUTDOOR TEMP SENSOR NOT USED IN MANUAL MODE STEAM HUMIDIFIER CONTROL MODULE FACTORY INSTALLED Z JUMPER GENERALA ire DEI OWNERS MANUAL 1 ELECTRONIC TEMPERATURE A COMPENSATING HUMIDISTAT TROUBLESHOOTING USING THE L E D COLOR FUNCTION Green Input power and senso
17. ain repair service under this limited warranty the consumer must send the defective part or the complete humidistat to the manufacturer 20F 7 37 100 THERE ARE NO EXPRESS WARRANTIES COVERING THIS HUMIDISTAT OTHER 30 1 28 500 THAN AS SET FORTH ABOVE THE IMPLIED WARRANTIES OF MERCHANTABILITY 40F 4b 23 000 AND FITNESS FOR PARTICULAR PURPOSE ARE LIMITED IN DURATION TO ONE YEAR THE MANUFACTURER ASSUMES LIABILITY IN CONNECTION 50F 10 18 000 WITH THE INSTALLATION OR USE OF THIS PRODUCT EXCEPT AS STATED IN 77 25 10 000 THIS LIMITED WARRANTY THE MANUFACTURER WILL IN NO EVENT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES This limited warranty gives you specific legal rights and you may also have other rights which vary from state to state Some states do not allow either limitations on implied warranties or exclusions from incidental or consequential damages so the above exclusion and limitation may not apply to you Any questions pertaining to this limited warranty should be addressed to the manufacturer U S A The manufacturer has elected not to make available the informal dispute settlement mechanism which is specified in the Magnuson Moss Warranty Act GENERAL FILTERS INC CANADIAN GENERAL FILTERS LTD 43800 GRAND RIVER AVE 39 CROCKFORD BLVD NOVI MICHIGAN 48375 1115 SCARBOROUGH ONTARIO M1R3B7 WWW GENERALAIRE COM WWW CGFPRODUCTS COM vsn GLLL GZ 8t NVDIHOIIN IAON JAY YSAIY GNVYD 008 ONI
18. air ne nuisent au bon fonctionnement de l humidistat 3 Retirez le bouton et le bo tier du socle en soulevant le bo tier par effet de levier au moyen d un petit tournevis enfonc dans l encoche lat rale du bo tier Recopiez le num ro de s rie inscrit l arri re du bo tier sur le bon de garantie 4 Montez le socle l horizontale au dessus des fils Vissez le directement au mur en utilisant les vis fournies 5 Branchez les fils aux bornes vis du module de commande tel qu illustr aux SCH MAS 1 2 3 4 ou 5 Remettez le bo tier et le bouton en place SCHEMA DES CABLAGE SCHEMA 1 CABLAGE DE L HUMIDIFICATEUR DE DERIVATION 24 VOLTS MANUEL D UTILISATION FIXATION SUR UN CONDUIT DE REPRISE D AIR N installez pas l humidistat sur un conduit d air chaud 1 Choisissez un emplacement pour l humidistat qui est au moins 24 po en amont de I humidificateur ou de la d rivation du conduit de reprise d air vitez les zones de radiation directe telles que les changeurs thermiques dans le compartiment du ventilateur 2 Localisez le gabarit au moyen d un niveau D coupez le trou pour le capteur comme le gabarit l indique Percez quatre trous de 3 32 po tel qu illustr 3 Retirez le bouton et le bo tier du socle en soulevant le bo tier par effet de levier au moyen d un petit tournevis enfonc dans l encoche lat rale du bo tier Recopiez le num ro de s rie inscrit l arri re du bo tier sur le bon de g
19. arantie 4 Posez la partie externe de la garniture d tanch it en mousse sur le socle de l humidistat et fixez le socle en place au moyen de quatre vis Lefil basse tension peut tre ins r dans l humidistat en le glissant sous la garniture en mousse 5 Raccordez les fils aux bornes vis qui se trouvent sur le module de commande tel qu illustr au SCH MAS 1 2 ou 3 Remettez le bo tier et le bouton en place CHOIX DE L EMPLACEMENT DU CAPTEUR DE TEMP RATURE EXT RIEURE Choisissez un emplacement qui convient S il s av re impossible d utiliser le capteur de temp rature ext rieure posez le cadran du mode manuel sur le bo tier avant de remettre le bouton et d placez le cavalier de r glage du mode en cons quence voir le sch ma de c blage 1 2 3 4 ou 5 Remettez le bo tier et le bouton en place 1 Le capteur de temp rature ext rieure ne doit pas tre fix sur un mur orient vers le Sud ni expos la lumi re directe du soleil 2 Le capteur de temp rature ext rieure ne doit pas tre install moins de 4 pieds des vents dont notamment les vents de s cheuse 3 Si un capteur de temp rature ext rieure est fix l int rieur d une prise d air frais assurez vous que la sonde n est pas pos e plus d un pieds de la paroi externe de l habitation 4 Assurez vous que les fils du capteur de temp rature ext rieure ne passent pas proximit d autres c bles en particulier les lignes haute
20. be d humidit pr cise le taux d humidit qui convient pour chaque temp rature l ext rieur Utilisez le tableau de classement de types d habitations qui suit pour choisir la courbe d humidit qui convient CLASSEMENT DES TYPES D HABITATIONS Courbe d humidit conseill e x Maisons types construites avant 1950 peu ou aucune isolation 2a3 des murs et des plafonds pas de pare vapeur Maisons types construites entre 1950 et 1965 isolant R6 2 po dans les murs et dans les plafonds pas de pare vapeur 4 5 Maisons types construites apr s 1965 isolant R11 3 5 po dans les murs et dans les plafonds pare vapeur en papier kraft Maisons types construites apres 1980 isolant R11 3 5 po dans les 5a6 murs et R19 6 po dans les plafonds pare vapeur en papier kraft minimum d un 1 po de mousse isolante l ext rieur fen tres a double vitrage Maisons haut de gamme construites apres 1990 isolant R19 6 po dans les murs et R38 12 dans les plafonds avec pare vapeur int rieur poly thyl ne minimum de 2 po de mousse isolante l ext rieur fen tres triple vitrage SI VOUS N TES PAS CERTAIN DU CLASSEMENT DE VOTRE DEMEURE R glez le bouton de commande 5 En cas de condensation diminuez le r glage une demi division la fois jusqu ce que la condensation disparaisse GENERALA L re RESIDENTIAL AIR TREATMENT PRODUCTS 1 HUMIDISTAT LECTRONIQUE A COMPENSATION THERM
21. e fa on faire fonctionner le br leur et le ventilateur de l appareil de chauffage Le fonctionnement peut ne fonctionne pas s av rer n cessaire pour mettre le syst me sous tension TE T shee od enmane 2 V rifiez les branchements des capteurs de temp rature ext rieurs v rifiez qu ils sont raccord s aux bornes SENSOR CAPTEUR du module de commande 3 Pour fonctionner en mode standard v rifiez que le cavalier est dans la position AUTO pour fonctionner en mode manuel v rifiez que le cavalier est dans la position MAN 4 V rifiez le c blage de l humidificateur Consultez les sch mas de c blage v rifiez que le cavalier est install sur les bornes 5 Contr lez les tensions aux bornes La tension devrait tre nulle pour un humidificateur Elite Steam et pour l humidificateur de puissance 1137 La tension devrait tre de 20 30 VCA pour les autres mod les 6 V rifiez que l humidificateur fonctionne en court circuitant l humidistat Le mode TEST fait fonctionner l humidificateur 1 minute seulement NE LAISSEZ PAS L HUMIDIFICATEUR EN MODE TEST CAR IL CESSERA DE FONCTIONNER APR S UNE MINUTE Le taux d humiti 1 D faillance de l humidificateur V rifiez l alimentation en eau les connexions lectriques et l tat du tampon l vaporateur id al n est pas one N ER tabli 2 Temps de fonctionnement de l humidificateur trop court Passez une alimentation eau chaude s il y
22. e whether jumper is installed in terminal block 5 Check voltage at OUT terminals There should be no voltage for an Elite Room Steam or a 1137 Power Humidifier Voltage should be 20 30 VAC for most others 6 Check for humidifier operation by bypassing humidistat TEST mode operates humidifier for 1 minute only DO NOT LEAVE IN TEST MODE HUMIDIFIER WILL NOT OPERATE AFTER 1 MINUTE Ideal Humidity 1 Technical fault with humidifier Check water supply electrical connections and condition of evaporator pad a 2 Humidifier run time is too short Switch water supply to hot water if appropriate use copper tubing 3 Excess air infiltration Seal sources o air loss 4 Humidifier is undersized Switch water supply to hot water if appropriate use copper tubing Add additional unit s or replace existing unit with larger unit GENERALA ir e EE OWNERS MANUAL 1 ELECTRONIC TEMPERATURE 5 COMPENSATING HUMIDISTAT TROUBLESHOOTING Continued TABLE 1 OUTDOOR RESISTANCE TEMPERATURE one LIMITED WARRANTY 20F 29 105 400 This humidistat if properly registered by the return of the warranty registration card to 10 23C 78 300 the manufacturer is warranted to the consumer against defects in materials and workmanship for period of two years from the date of installation Any defective parts OF 18 C 61 500 will be repaired without charge except for removal reinstallation and transportation 10F 12C 46 500 costs To obt
23. es as shown 3 Remove the knob and housing from the base by prying with a small screwdriver at the notch in the side of the housing Copy serial number located on housing back onto the warranty registration 4 Place the outer part of the foam gasket on the humidistat base and mount the base with four screws Low voltage wire may enter the humidistat under the foam seal 5 Connect wires to screw terminals on the control assembly as shown in DIAGRAM 1 2 4 5 Replace housing and knob LOCATING OUTDOOR TEMPERATURE SENSOR Determine suitable location If it is impractical to utilize the outdoor temperature sensor place the manual mode dial plate on the housing before replacing knob and move the mode selection jumper see wiring diagram 1 2 3 4 or 5 1 Outdoor temperature sensor may not be mounted on the South side of the house or in direct sunlight 2 Outdoor temperature sensor may not be located closer than 4 feet to exhaust vents dryer vents etc 3 If outdoor temperature sensor is mounted in fresh air intake duct make sure the probe is no further than 1 foot from outside wall 4 Make sure wiring for outdoor temperature sensor is not close to other wires particularly high voltage 5 Outdoor temperature sensor must be at least 6 above expected snow line WIRING WARNING Disconnect electrical power before beginning installation 120 volts may cause injury or even death Refer to wiring DIAGRAM 1 DIAGRAM 2 DI
24. is mounted in fresh air intake duct make sure the probe is no further than 1 foot from outside wall Humidifier 1 When the humidity in the home is less than the knob setting or humidity curve the control will operate humidifier operation until the humidity is higher Reduce knob setting continuous 2 Use TEST mode Verify that the humidifier operates for 1 minute and shuts off 3 Measure resistance of the outdoor temperature sensor if installed by removing the leads of the sensor from the terminals Measure the resistance across the wires with an ohmmeter Confirm reading with TABLE 1 4 Outdoor temperature sensor may not be mounted on the South side of the house or in direct sunlight 5 Outdoor temperature sensor may not be located closer than 4 feet to exhaust vents dryer vents etc 6 If outdoor temperature sensor is mounted in fresh air intake duct make sure the probe is no further than 1 foot from outside wall 7 Remove wires from control OUT terminals If humidifier continues to operate check solenoid valve No Humidifier 1 Set thermostat to operate both furnace burner and blower Operation may be necessary for system power Operation in TEST mode 2 Check outdoor temperature sensor connections Check connection to SENSOR terminals of control 3 For standard operation check that jumper is in AUTO position For manual operation check that jumper is in MAN position 4 Inspect humidifier wiring Refer to wiring diagrams not
25. ituer dans la plage de 20 30 VCA se met en marche et s arr te 2 Assurez vous que les fils du capteur de temp rature ext rieure ne passent pas proximit d autres c bles en particulier les lignes haute tension sans arr t 3 Si le module de commande de l humidificateur est install dans un conduit de reprise d air assurez vous qu il se trouve au moins 24 po en amont de la sortie de l humidificateur L humidificateur 1 La temp rature l ext rieur est sup rieure a 50 F ou inf rieure 20 F auquel cas l humidificateur fonctionnera uniquement en ne fonctionne mode TEST cela est tout fait normal qu en mode TEST 2 Le taux d humidit dans la maison est sup rieure au 45 HR L humidificateur fonctionnera uniquement en mode TEST cela est tout fait normal 3 Le taux d humidit dans l habitation est sup rieur au r glage du bouton de commande le module de commande de l humidificateur ne pourra pas actionner l humidificateur 4 Mesurez la r sistance du capteur de temp rature ext rieure s il y a lieu en d branchant les fils du capteur des bornes Mesurez la r sistance entre les fils au moyen d un ohm tre Comparez la valeur mesur e celles qui figurent au TABLEAU 1 5 Le capteur de temp rature ext rieure ne doit pas tre fix sur un mur orient vers le Sud ni expos la lumi re directe du soleil 6 Le capteur de temp rature ext rieure ne doit pas tre install moins de 4 pieds des vents y
26. r connections are properly made Green blinking Connections are properly made humidistat is in Test Mode Red Electrical connections are not properly made Off No power or insufficient power to the control TROUBLESHOOTING SYMPTOM DIAGNOSTIC STEPS Humidifier 1 Check voltage at humidifier control 24 V terminals Voltage should be steady at 20 30 VAC turns on and off repeatedly 2 Make sure wiring for outdoor temperature sensor is not close to other wires particularly high voltage If mounted on return air duct make sure humidifier control is at least 24 upstream of humidifier s air discharge Humidifier 1 Outdoor temperature is greater than 50 or less than 20 F The humidifier control will only operate in TEST this is normal operation A LEUR 2 Humidity level in the home is higher than 45 RH The humidifier control will only operate in TEST this is normal operation only 3 Humidity level in the home is higher than knob setting Humidifier control will not operate the humidifier 4 Measure resistance of the outdoor temperature sensor if installed by removing the leads of the sensor from the terminals Measure the resistance across the wires with an ohmmeter Confirm reading with TABLE 1 5 Outdoor temperature sensor may not be mounted on the South side of the house or in direct sunlight 6 Outdoor temperature sensor may not be located closer than 4 feet to exhaust vents dryer vents etc 7 If outdoor temperature sensor
27. trol of most humidifiers The humidistat uses microchip electronics for precise control and is designed for wall mounting in the living area or mounting on the return air duct RANGE 10 to 45 RH ELECTRICAL RATING 30 VAC 60 VA OPERATING MODES The E1 has two operating modes The standard AUTO operating mode compensates for outdoor temperature By automatically raising the humidity as outdoor temperatures rise the E1 allows the highest possible humidity By automatically lowering the humidity as temperatures drop the E1 minimizes the risk of condensation on cold surfaces Your E1 Electronic Humidistat when operating in its AUTO outdoor temperature compensating mode will provide you and your family with optimum comfort and is an investment in the integrity of your home s structure The MANUAL mode is used when conditions require constant humidity levels or when technical issues make use of the AUTO mode impractical Desired humidity levels are selected manually and any adjustments for outdoor temperature must also be made manually OWNERS MANUAL MANUAL MODE Set the control knob to the relative humidity recommended in the chart below for corresponding average outdoor temperature This setting is suitable for most homes built after 1965 For older homes reduce the control knob setting 5 relative humidity For newer quality built homes advance the control knob setting 5 relative humidity for better comfort Ge RECOMMEND
28. ut entra ner des dommages mat riels et des blessures Les propri taires de l habitation doivent lire et comprendre le mode d emploi du 1 et de tout humidificateur dont celui ci assure la commande Un mauvais usage peut entra ner un apport excessif ou insuffisant d humidit L exc s d humidit peut provoquer condensation fissuration et moisissure La condensation l int rieur d un b timent peut provoquer une perte de r sistance de la structure La condensation favorise aussi la croissance de la moisissure ce qui peut causer des l sions et abimer la structure et le contenu du b timent Pour toute question relative la s curit et au E1 veuillez communiquer avec General Filters Inc ll USAGE L humidistat lectronique 1 assure la commande basse tension de la plupart des humidificateurs L humidistat fait appel des circuits lectroniques micropuces pour procurer une r gulation tr s pr cise Il est con u pour tre fix au mur dans les salles de s jour ou pour tre install dans un conduit de reprise d air PLAGE D HUMIDIT S RELATIVES 10 45 CALIBRE 30 VAC 60 VA MODES DE FONCTIONNEMENT Le E1 peut fonctionner selon deux modes Le mode automatique AUTO qui est standard assure la compensation automatique de la temp rature l ext rieur En augmentant automatiquement l humidit mesure que la temp rature augmente l ext rieur le 1 procure une humidit maximum En diminuant a
29. utomatiquement l humidit mesure que la temp rature diminue le 1 r duit au minimum les risques de condensation sur les surfaces froides L humidistat lectronique 1 assurera votre famille lorsqu il fonctionne en mode AUTO un maximum de confort en compensant automatiquement les variations de temp rature l ext rieur C est un investissement dans l int grit de la structure de votre domicile Le mode MANUEL est utilis lorsque les conditions ambiantes exigent des r glages constants du taux d humidit ou lorsque des questions d ordre technique rendent impossible l utilisation du mode AUTO Les taux d humidit souhait s sont r gl s manuellement Tout ajustement afin de compenser les variations de temp rature l ext rieur doit aussi tre fait manuellement MANUEL D UTILISATION MODE MANUEL R glez le bouton de commande au taux d humidit relative conseill qui correspond la temp rature ext rieure moyenne voir le tableau ci dessous Ce r glage conviendra la plupart des maisons construites apr s 1965 Pour les maisons plus anciennes diminuez le r glage du taux d humidit relative de 5 Pour les maisons haut de gamme construites plus r cemment augmentez le r glage du taux d humidit relative de 5 pour un confort accru TEMP RATURE R GLAGE EXT RIEURE CONSEILL 20 29 15 10 F 23 C 20 0 18 C 25 10 12 C 30 20 F 7 C 35 30 F 1 40
Download Pdf Manuals
Related Search
Related Contents
DataVideo MP-6000MD サイトマスタ™ Sirene da esterno via radio modd. GAIA e HYDRA Composants inférieurs de la suspension Introducing Lantmäteriet`s gravity data in ArcGIS with Vérification de la gérance financière du portefeuille de logements User manual ŠKODA Superb ISTRUZIONI PER L`USO - Media Portal TTS-280K Copyright © All rights reserved.