Home
Canada – Installation, Ballast & Specification Guide
Contents
1. BACS A ii pA Canada Installation Ballast amp Specification Guide Philips LED T8 InstantFrt Lamp Please take the time to read this quick installation guide The guide contains important information and notes regarding the installation and operation e Please keep this Quick Installation Guide for future reference e Product is not dimmable e Compatible only with instant start ballasts e Philips LED T8 InstantFit lamps are not compatible with luminaires that use a remote starter e Modifications to the product void the warranty e Suitable to replace 18 fluorescent lamps as specified on the product label PHILIPS Product Specifications Product Order Average System Initial Length Bulb No Code Bare Lamp Power W Power W Lumens In Type Low Normal High Low Normal High Low Normal High Ballast Ballast Ballast Ballast Ballast Ballast Ballast Ballast Ballast Factor Factor Factor Factor Factor Factor Factor Factor Factor Cr 0 88 CAL CU CA 1 CAL CU CA 1 CALE 14 5T8 48 433060 3000 IF 10 1 12 5 14 5 20 14 5 16 5 22 1300 1500 1900 40 000 G13 48 T8 14 5T8 48 433268 3500 IF 10 1 12 5 14 5 20 14 5 16 5 22 1300 1500 1900 40 000 GI3 48 T8 14 5T8 48 433078 4000 IF 10 1 12 5 14 5 20 14 5 16 5 22 1400 1600 2000 40 000 G13 48 T8 14 5T8 48 433086 5000 IF 10 1 12 5 14 5 20 14 5 16 5 22 1450 1650 2100 40 000 G13 48 T8 List of Compatible Ballasts Philips Advance Models GOPA 2P32 SC G
2. OPA 4P32 SC GOPA 2P32 LW SC GOPA 4P32 LW SC IOPA 2P32 N IOPA 4P32 N IOPA 2P32 LW N IOPA 4P32 LW N IOP 2P32 N IOP 4P32 N IOP 2P32 LW N IOP 4P32 LW N ICN 2P32 N ICN 4P32 N ULT Models B2321347HP A B4321347HP GE Models GE232MAX347 N GE432MAX347 N UltraSave Models UT232347 UT432347 4 Check Ballast 5 LED T8 InstantFit 6 LED T8 InstantFit 7 3 Fluorescent 2 Fluorescent Instructions Switch off power to the luminaire 2 Remove diffuser if provided 3 Remove the existing fluorescent lamps from the luminaire Note Verify the fluorescent tube type is listed on the label of Philips LED T8 InstantFit lamp 4 Confirm that the ballast in the luminaire typically located in the ballast channel is an instant start ballast listed in the compatibility guide Install the Philips LED T8 InstantFit lamp one for each fluorescent lamp removed Replace diffuser if removed in step 2 7 Switch on power to the luminaire Instructions Coupez l alimentation du luminaire m Retirer le diffuseur si inclu UIJ Retirez les lampes fluorescentes du luminaire V rifier que le ballast dans le luminaire est un ballast allumage instantan g n ralement situ dans le canal du ballast 4 Sile ballast n est pas un ballast allumage instantan veuillez arr ter et contacter le fabricant Autrement passez l tape 2 5 6 Installer la lampe LED T8 InstantFit Philips une pour chaque lampe flu
3. R UN BALLAST LECTRONIQUE SI LA LAMPE NE S ALLUME PAS LORSQUE LE LUMINAIRE EST MIS SOUS TENSION RETIRER LA LAMPE DU LUMINAIRE ET CONTACTER LE FABRICANT DE LA LAMPE OU UN ELECTRICIEN QUALIFIE MISE EN GARDE CE PRODUIT EST SUSCEPTIBLE DE CAUSER DE L INTERF RENCE AVEC LES QUIPEMENTS RADIO ET NE DEVRAIT PAS TRE INSTALL PRES DES APPAREILS DE COMMUNICATION DE SECURITE MARITIME OU TOUT AUTRE EQUIPEMENT DE COMMUNICATION OU DE LA NAVIGATION QUI FONCTIONNE UNE BANDE ENTRE 0 45 ET 30 MHZ CE DISPOSITIF N EST PAS PR VU POUR UN USAGE AVEC LES INDICATEURS DE SORTIE 2013 Koninklijke Philips N V Philips Lighting Philips Lighting PH l LI PS All rights reserved A Division of Philips North America A Division of Philips Canada Printed in USA 09 13 200 Franklin Square Drive 281 Hillmount Road Somerset NJ 08873 Markham Ontario Phone 855 486 2216 Canada L6C 253 www philips com Phone 800 555 0050
4. orescente retir e Remplacer le diffuseur si inclu 7 Allumez l interrupteur du luminaire CAUTION IF THE LAMP OR LUMINAIRE EXHIBITS UNDESIRABLE OPERATION BUZZING FLICKERING ETC IMMEDIATELY TURN OFF POWER REMOVE LAMP FROM LUMINAIRE AND CONTACT THE MANUFACTURER CAUTION RISK OF FIRE DO NOT INSTALL IN A PRE HEAT LUMINAIRE WARNING RISK OF FIRE USE ONLY IN PLACE OF FLUORESCENT LAMPS SPECIFIED ON LABEL SEE INSTRUCTIONS THIS LAMP ONLY OPERATES ON ELECTRONIC BALLASTS IF LAMP DOES NOT LIGHT WHEN THE LUMINAIRE IS ENERGIZED REMOVE LAMP FROM LUMINAIRE AND CONTACT LAMP MANUFACTURER OR QUALIFIED ELECTRICIAN THIS PRODUCT MAY CAUSE INTERFERENCE TO RADIO EQUIPMENT AND SHOULD NOT BE INSTALLED NEAR MARITIME SAFETY COMMUNICATIONS EQUIPMENT OR OTHER CRITICAL NAVIGATION OR COMMUNICATION EQUIPMENT OPERATING BETWEEN 0 45 30MHZ THESE DEVICES ARE NOT INTENDED FOR USE WITH EMERGENCY EXIT FIXTURES OR EMERGENCY EXIT LIGHTS Lamps must be operated within an ambient fixture temperature of 4F 20c and 13F 45c to ensure UL compliance AVERTISSEMENTS MISES EN GARDE ET MODE D EMPLOI MISE EN GARDE SI LA LAMPE OU LE LUMINAIRE MONTRE UN FONCTIONNEMENT INAPPROPRIE BOURDONNEMENT CLIGNOTEMENT ETC INTERROMPRE IMMEDIATEMENT LE COURANT ENLEVER LA LAMPE DU LUMINAIRE ET CONTACTER LE FABRICANT MISE EN GARDE RISQUE D INCENDIE NE PAS INSTALLER DANS UN LUMINAIRE DU TYPE A PRECHAUFFAGE MISE EN GARDE CETTE LAMPE FONCTIONNE SEULEMENT SU
Download Pdf Manuals
Related Search
Related Contents
Pelican SabreLite 2000 Flashlight - Xenon Bulb - 3.30 W - C - ABSBody, Manual - FAST.Eu FSG 70 FSG 71M Imago 60/40 Drucker Laser 2000 eBOX639-840 & eBOX-639-840-FL Series Embedded Product Manual Electrolux 316495008 Ventilation Hood User Manual LES COMPETENCES CLES DES CONTROLEURS DE GESTION Copyright © All rights reserved.
Failed to retrieve file