Home
Electrolux 316495008 Ventilation Hood User Manual
Contents
1. CONNECTOR Mount the discharge collar above the hood Fig 4 DISCHARGE we COLLAR NON DUCTED CONFIGURATION amp NOTE Purchase a Non ducted recirculation KIT from your dealer Model DFKTPC40EC 1 Insert the non ducted recirculation plenum through the support frame openings Fig 5 2 Through the support frame openings fit the duct connector to the plenum locking it with a turning movement Fig 6 3 Fix a 5 duct to the duct connector of the non ducted Installation Q Connect decorative flue 1 Secure the upper flue to the upper support frame with the mounting screws 3 9x9 5mm Fig 8 2 Insert the lower flue moving it completely towards the top and fix it temporarily with a tape Fig 9 MOUNTING SCREWS 3 9x9 5mm ROOMS WITH 10 FOOT CEILINGS Rooms with 10 foot ceilings require flue extension model EXPC75GS8 available from your local dealer Discard the flue supplied with the product Replace it with the flue extension EXPC75GS Continue with the instructions above points 1 and 2 Install the hood amp NOTE Atleast three people will be required to mount the hood Fix the hood to the support frame with 6 3 9x9 5mm mounting screws and 2 serrated washers Fig 10 MOUNTING SCREWS 3 9x9 5mm SERRATED WASHERS 10 Installation Connect ductwork DUCTED HOODS ONLY 1 Use 6 round metal duct to connect the discharge collar on the hood to the du
2. 1 Support Frame Bracket 1 Discharge Collar 4 Mounting Screws 6 x 70 16 Mounting Screws 3 9 x 9 5mm Pan Head 4 Washers D 6 4mm 6 Serrated Washers 1 Wiring Box Cover 1 Wire Clamp 1 Installation Instructions 1 Warranty Card gt WIRING BOX COVER 4 WASHERS D 6 4mm SUPPORT DECORATIVE FRAME SCREWS 6 x 70mm _ 6 SERRATED WASHERS 2 one SUPPORT FRAME BRACKET 16 MOUNTING SCREWS 3 9 x 9 5mm Pan Head 6 Installation Install the ductwork A CAUTION s CAP To reduce the risk of fire use only metal ductwork 1 Decide where the ductwork will run between the Zn Al a hood and the outside LE ER loo wee ROUND ELBOW FLUE By E perform most efficiently 7 ae Hoop 2 A straight short duct run will allow the hood to ai f 24 TO 30 ABOVE 3 Long duct runs elbows and transitions will reduce COOKING SURFACE the performance of the hood Use as few of them as possible Larger ducting may be required for best performance with longer duct runs R E E R R ea EEE EEE Ee mu 4 Install a roof or wall cap Connect round metal ductwork to cap and work back towards hood location Use duct tape to seal the joints between ductwork sections 5 Never make the size or area of the ductwork smaller than the size that originates at the hood 6 Bigger ductwork is better 7 Keep duct lenght less than 50 linear feet 8 Minimize use of elbow
3. Use amp Care Guide Installation Instructions Vent Hood A Electrolux 2 Finding Information Please read and save this guide Thank you for choosing Electrolux the new premium brand in home appliances This Use amp Care Guide is part of our commitment to customer satisfaction and product quality throughout the service life of your new appliance We view your purchase as the beginning of a relationship To ensure our ability to continue serving you please use this page to record important product information Keep a record for quick reference Purchase date Electrolux model number Electrolux serial number see picture for location NOTE Registering your product with Electrolux enhances our ability to serve you You can register online at www electroluxusa com or by dropping your Product Registration Card in the mail Questions For toll free telephone support in the U S and Canada 1 877 4ELECTROLUX 1 877 435 3287 For online support and Internet product information visit http www electroluxusa com Table of contents Finding information 2 Maintenance cccccccceceeeceeeeeeeeeuaeeeueeeuneeanees 11 SEE a seed nn ee 0 Grease S Se eee nn ee ee ee 11 Verify package contents 9 Non Ducted recirculation filters c ccc secsesssseesssseeeens 11 SAT tareeredse nnana Aa O HOMO SE ne 1
4. or cleaning compounds to remain in contact with stainless steel for extended periods Many of these compounds contain chemicals which may be harmful Rinse with water after exposure and wipe dry with a clean cloth Painted surfaces should be cleaned with warm water and mild detergent only 12 Operation Controls 9 Le light filter fan switch reset on off switch switches fan speed switches T GG GB MG display Dead front mode Stand by mode Q In dead front mode press any key for enter in stand by mode If the hood is in stand by mode after 10 seconds on return automatically in dead front mode Light switch Press any key for enter in stand by mode Push the light switch once to turn the lights ON to a dim level Push a second time to turn the lights ON to a brighter level Push a third time to turn the lights OFF stand by mode Fan speed switches Press any key for enter in stand by mode The fan speed switches turns the fan on 1 fan ON at low speed 2 fan ON at medium low speed 3 fan ON at medium high speed 4 fan ON at high speed Fan on off switch Push this fan switch to turn OFF the fan The hood turns in the stand by mode Delay shut off switch Pressing this switch when is active any speed sets a timer which keeps the fan operating at this speed for 10 minutes the number 10 appears in the display After 10 minutes the hood turns in the stand by mode P
5. exclusions listed below home and any costs for pick up and Applicable to apply delivery of the appliance required the State of Alaska because of service NORMAL This warranty applies only to products in ordinary household use and the consumer is responsible for RESPONSIBILITIES the items listed below OF THE CONSUMER 1 Proper use of the appliance in accordance with instructions provided with the product 2 Proper installation by an authorized servicer in accordance with instructions provided with the appliance and in accordance with all local plumbing electrical and or gas codes 3 Proper connection to grounded power supply of sufficient voltage replacement of blown fuses repair of loose connections or defects in house wiring 4 Expenses for making the appliance accessible for servicing such as removal of trim cupboards Shelves etc which are not a part of the appliance when it was shipped from the factory 5 Damages to finish after installation 6 Replacement of light bulbs and or fluorescent tubes on models with these features This warranty does not cover the following EXCLUSIONS 1 CONSEQUENTIAL OR INCIDENTAL DAMAGES SUCH AS PROPERTY AND INCIDENTAL EXPENSES RESULTING FROM ANY BREACH OF THIS WRITTEN OR ANY IMPLIED WARRANTY NOTE Some states do not allow the exclusion or limitation of incidental or consequential damages so this limitation or exclusion may not apply to you 2 Service calls which do not involve malfunction
6. four halogen bulbs max 20W 12V Type T3 bulb G4 Base A WARNING Halogen Bulb Key 5304454951 SWITCH OFF THE ELECTRICITY SUPPLY A WAR N l NG Remove the grease filters ALWAYS SWITCH OFF THE ELECTRICITY SUPPLY OP the fuse box BEFORE CARRYING OUT ANY OPERATIONS ON THE Replace with the same type of fuse 5x20mm 4A 125V APPLIANCE 5 Fuse Key 5304455332 To change bulbs 1 Open the cover by prying from the proper slots DO NOT ROTATE CAUTION BULB MAY BE HOT 3 Replace with a max 20W 12V Type T3 bulb G4 Base bulb Do not touch replacement bulb with bare hands If the bulb is touched with the bare hand it should be cleaned with a lint free cloth moistened with methylated spirit FUSE BOX 14 Wiring N WARNING This range hood must be properly grounded Improper grounding can result in a risk of electric shock The unit should be installed by a qualified electrician in accordance with all applicable national and local electrical codes Turn off electrical power at service entrance before wiring 1 Remove the 2 screws of the upper flue and move the upper flue towards the bottom 2 Feed 6 of power cable through the top opening of the support frame bracket installed on ceiling and into the wiring box For the Non Ducted Hoods do not use the upper hole of the wiring box Secure cable to the wiring box using an appropriate connector 3 Feed the range hoods power cable through the lower ho
7. 1 Install Me dUCIWOTK sitet ee se 6 Operaliol SE ne de 12 HASTA SUP OL RSS EE LEE CO E E E E EATE A A E A E 12 Preparethe DOOU iersinii 8 Halogen B IDS 2 13 Connect decorative UG ccxescsinersancetenssineveietaneteneeneusemuneaniones 9 Fuse TEDIACEIMENE 2 2 13 Instal TING NOOA sieer noscenaugetoencceesereds M a 14 Connect dUCIWOrK 10 Warranty information 15 RS AN TCT Ss A E an 10 2007 Electrolux Home Products Inc All rights reserved Printed in Italy Important Safety Instructions Read all instructions before using this appliance Save these instructions for future reference Do not attempt to install or operate your appliance until you have read the safety precautions in this manual Safety items throughout this manual are labeled with a WARNING or CAUTION based on the risk type A WARNING This symbol alerts you to situations that may cause serious body harm death or property damage This symbol alerts you to situations that may cause bodily injury or property damage N CAUTION INTENDED FOR DOMESTIC COOKING ONLY A WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING 1 Use this unit only in the manner intended by the manufacturer If you have questions contact the manufacturer at the address or telephone number listed in the warranty 2 Before servicing or cleaning uni
8. ctwork above Fig 11 2 Use duct tape to make all joints secure and air tight 3 Remove the tape from the lower flue and set it in place on the hood Fig 11 6 ROUND METAL DUCT Install filters DUCTED AND NON DUCTED HOODS 1 To remove the GREASE filters pull the metal latch tab outside and unlock the filter 2 To install the GREASE filters align rear filter tabs with slots inthe hood Depress the metal latch tab push filter into position and release Make sure filter is securely engaged after installation NOTE Prior to use remove protective film from the filter frame NON DUCTED HOODS ONLY 1 To remove the CHARCOAL filter push in on the front filter latch Pull the filter down to disengage the rear filter tabs 2 To install the CHARCOAL filter align the rear filter tabs with slots in the hood Push the filter up into place until the front latch snaps securely into the slot Make sure the filter is securely engaged after assembly 3 Install GREASE filters after charcoal filter is in Stalled GREASE FILTERS NON DUCTED lt lt RECIRCULATION FILTER Maintenance Proper maintenance of the Range Hood will assure proper performance of the unit Grease filters The grease filters should be cleaned when the filter reset switch will be illuminated Use a warm detergent solution Grease filters are dishwasher safe See INSTALL FILTERS section for removal and installat
9. en cooking at high heat or when flambeing food i e Crepes Suzette Cherries Jubilee Peppercorn Beef Flambe C Clean ventilating fans frequently Grease should not be allowed to accumulate on fan or filter D Use proper pan size Always use cookware appropriate for the size of the surface element 4 Safety A WARNING TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE OBSERVE THE FOLLOWING s SMOTHER FLAMES with a close fitting lid cookie sheet or metal tray then turn off the burner BE CAREFUL TO PREVENT BURNS If the flames do not go out immediately EVACUATE AND CALL THE FIRE DEPARTMENT 2 NEVER PICK UP A FLAMING PAN You may be burned 3 DO NOT USE WATER including wet dishcloths or towels violent steam explosion will result 4 Use an extinguisher ONLY if A You know you have a Class ABC extinguisher and you already know how to operate it B The fire is small and contained in the area where it started C The fire department is being called D You can fight the fire with your back to an exit Based on Kitchen Fire Safety Tips published by NFPA N CAUTION 1 To reduce risk of fire and to properly exhaust air be sure to duct air outside Do not vent exhaust air into spaces within walls or ceilings or into attics crawl spaces or garages 2 Take care when using cleaning agents or detergents 3 Avoid using food products that produce fla
10. ion instructions Once the grease filters are cleaned and installed press in and hold the filter reset switch for approximately 3 seconds Non Ducted Recirculation filters The non ducted recirculation filter should be changed when the filter reset switch will be illuminated and blink See INSTALL FILTERS section for removal and installation instructions Once the new charcoal filter is installed press in and hold the filter reset switch for approximately 3 seconds Hood cleaning Stainless steel is one of the easiest materials to keep clean Occasional care will help preserve its fine appearance Cleaning tips Hot water with soap or detergent is all that is usu ally needed Follow all cleaning by rinsing with clear water Wipe dry with a clean soft cloth to avoid water marks For discolorations or deposits that persist use a non scratching household cleanser or stainless steel polishing powder with a little water and a soft cloth For stubborn cases use a plastic scouring pad or soft bristle brush together with cleanser and water Rub lightly in direction of polishing lines or grain of the stainless finish Avoid using too much pressure which may mar the surface DO NOT allow deposits to remain for long periods of time DO NOT use ordinary steel wool or steel brushes Small bits of steel may adhere to the surface causing rust DO NOT allow salt solutions disinfectants bleaches
11. le of the wiring box use a wire clamp located in the Hardware Package 4 Make electrical connections Wire white to white black to black and green to green 5 Push all wiring inside the wiring box Install the wiring box cover with 2 3 9x9 5mm screws and 2 serrated washers making sure wires are not pinched 6 Tuck excess power cable inside the flue 7 Reinstall the upper flue p LINE IN 120 VOLTS 60 HZ WIRING BOX COVER BLK BLK WIRE CLAMP GRN GRN Warranty Information 19 In the U S A your appliance is warranted by Electrolux Home Products North America a division of White Consolidated Industries Inc We authorize no person to change or add to any of our obligations under this warranty Our obligations for service and parts under this warranty must be performed by us or authorized Electrolux Home Products North America servicer In Canada our appliance is warranted by Electrolux Canada Corp WARRANTY THROUGH OUR AUTHORIZED SERVICERS THE CONSUMER WILL BE PERIOD WE WILL RESPONSIBLE FOR FULL ONE YEAR One year from Pay all costs for repairing or replacing any parts of Costs of service calls that are listed WARRANTY original purchase this appliance which prove to be defective in under NORMAL RESPONSIBILITIES OF date materials or workmanship THE CONSUMER LIMITED Time periods All of the provisions of the full and limited Costs of the technician s travel to the WARRANTY listed above warranties above and the
12. mes under the Range Hood 4 For general ventilating use only Do not use to exhaust hazardous or explosive materials and vapors 5 To avoid motor bearing damage and noisy and or unbalanced impellers keep drywall spray construction dust etc off power unit 6 Your hood motor has a thermal overload which will automatically shut off the motor if it becomes over heated The motor will restart when it cools down If the motor continues to shut off and restart have the hood serviced 7 Forbest capture of cooking impurities the bottom of the hood should be a minimum of 24 and a maximum of 30 above the cooking surface 8 Two installers are recommended because of the large size and weight of this hood 9 This product is equipped with a thermostat which may start blower automatically To reduce the risk of injury and to prevent power from being switched on accidentally switch power off at service panel and lock or tag service panel 10 Please read specification label on product for further information and requirements AUTOMATICALLY OPERATED DEVICE TO REDUCE THE RISK OF INJURY DISCONNECT FROM POWER SUPPLY BEFORE SERVICING THE UNIT IS EQUIPPED WITH AN INTEGRAL DISCONNECTING SWITCH LOCATED INSIDE THE BLOWER HOUSING INTEGRAL DISCONNECTING SWITCH Verify package contents 5 Unpack hood and check contents You should receive 1 Hood 1 Decorative Flue Assembly 1 Support Frame 1 Parts Bag containing
13. or defects in workmanship or material or for appliances not in ordinary household use The consumer shall pay for such service calls 3 Damages caused by services performed by servicers other than Electrolux Home Products North America or its authorized servicers use of parts other than genuine Electrolux Home Products parts obtained from persons other that such servicers or external causes such as abuse misuse inadequate power supply or acts of God 4 Products with original serial numbers that have been removed or altered and cannot be readily determined IF YOU NEED Keep your bill of sale delivery slip or some other appropriate payment record The date on the bill SERVICE establishes the warranty period should service be required If service is performed it is in your best interest to obtain and keep all receipts This written warranty gives you specific legal rights You may also have other rights that vary from state to state Service under this warranty must be obtained by contacting Electrolux Home Products This warranty only applies in the 50 states of the U S A Puerto Rico and Canada Product features or specifications as described or illustrated are subject to change without notice All warranties are made by Electrolux Home Products North America a division of White Consolidation Industries Inc In Canada your appliance is warranted by Electrolux Canada Corp USA Canada 1 800 944 9044 1 866 294 9911 Electrolux Home Produc
14. s and transitions 4 or less 9 Always separate 90 degree elbows with at least 2 feet of straight ductwork 10 Place transitions at least 1 foot from the hood outlet Installation 7 Install support system 1 At hood location install 2 X 4 cross framing between ceiling joists using dimensions shown Lag CROSS FRAMING 2 Finish the ceiling surface Be sure to mark the location of the ceiling joists and cross framing 3 Secure the support frame bracket to joists and cross framing with four screws provided 6x70mm and four washers D 6 4mm Make sure screws are driven into center of joists and framing for maximum strength 4 Fix the support frame to the support frame bracket with 4 3 9x9 5mm mounting screws Fig 2 5 Adjust the overall height of the support frame Loosen and re tighten the 4 screws in the height adjustment slots as necessary sad oe x UmmM MOUNTING SCREWS 3 9x9 5mm HEIGHT ADJUSTMENT SLOTS 8 Installation Prepare the hood recirculation plenum Fig 6 4 Mount the 6 5 adapter above hood Fig 7 NON DUCTED NOTE RECIRCULATION PLENUM On stainless steel hoods carefully remove the plastic protective film from all exterior surfaces of the hood and decorative flues prior to final installation Fix the electrical mounting plate with 2 3 9x9 5mm screws and 2 serrated washers Fig 3 ELECTRICAL MOUNTING MOUNTING PLATE SCREWS 3 9x9 5mm DUCTED CONFIGURATION
15. t switch power off at service panel and lock service panel to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel 3 Installation work and electrical wiring must be done by a qualified person s in accordance with all ap plicable codes and standards including fire rated construction codes and standards 4 Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent backdrafting Fol low the heating equipment manufacturer s guide safety lines and safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigera tion and Air Conditioning Engineers ASHRAE and the local code authorities 5 When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities 6 Ducted fans must always be vented to the outdoors 7 Do not use this unit with any separate solid state speed control device 8 To reduce the risk of fire use only metal ductwork 9 This unit must be grounded TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE A Never leave surface units unattended at high settings Boilovers cause smoking and greasy spillovers that may ignite Heat oils slowly on low or medium settings B Always turn hood ON wh
16. ts Electrolux Home Products North America North America P O Box 212378 802 boul L Ange Gardien Augusta GA 30917 L Assomption Quebec JoW 1T6 4 Electrolux
17. ush this switch once to turn the timer Off Filter reset switch When the filter switch is illuminated it is necessary to clean the GREASE FILTERS Once the grease filters are cleaned and installed press in and hold the filter reset switch for approximately 3 seconds When the filter switch is illuminated and blink it is necessary to replace the CHARCOAL FILTER Once the new charcoal filter is installed press in and hold the filter reset switch for approximately 3 seconds Heat Sentry Your hood is equipped with a HEAT SENTRY thermostat This thermostat is a device that will turn on or speed up the blower if it senses excessive heat above the cooking surface 1 If blower is OFF it turns blower ON to HIGH speed 2 If blower is ON at a lower speed setting it turns blower up to HIGH speed When the Heat Sentry is active the word HS appears in the display and the tone alarm is active To disarm the tone alarm press the 4 fan speed switch When the temperature level drops to normal the blower will return to its original setting IMPORTANT The HEAT SENTRY thermostat can start the blower even if the hood is turned OFF When this occurs it is impossible to turn the blower OFF with its switch If you must stop the blower do it from the integral disconnecting switch located inside the blower housing Heat Sentry active Operation 13 Halogen bulbs Fuse replacement This range hood requires