Home
Notice Horloge mère Microquartz 6
Contents
1. display D1 D2 220 V 3 wires N he ia minute 24 V Ip D1 D2 220 V 3 wires D1 de 1 2 minute 24 V 15 6 D2 220 Telesect impulses 220 V 4 wires 1 0 re D minute 24 V FER PO 07 T l sect impulses 220 V 4 wires 4 Ye minute 24 V 5 3 G 6 2 j j D 220 po og Synchronous wired 3wired D FR n Example 24 V min impulse D1 D2 3 wire code PO 04 Press 4 times the second key to obtain Enter The display shows P1 Selection of the impulse duration P 3 Impulse duration is adjustable to the minute 1 2 minute SR2 output clock line terminal 18 from 1 sec to 1 8 sec The clock is delivered with 1 3 sec duration Press the second key to disply the required duration EG Impulse duration 1 8 seconds Enter The display shows P2 Selection of operating mode For the Microquartz 6 always enter For the Microquartz 6 R select the operating mode Stand alone enter Slave operation controlled by another master clock On minute On 1 2 minute impulse Pi 13 Pi B P2 Hi P2 Hi P2 D P2 De 17 18 P3 Selection of radio synchro mode P2 00 must be entered P3 00 official time by DCF 77 or FRANCE INTER P3 1 official time by DCF 77 or FRANCE INTER plus 1 hour P3 Synchro radio without summer winter time changeover P3 1 official time by DCF 77 ofr FRANCE INTER les
2. Set the circuit switch to Normal Set the keypad switch to OFF Erasing a programme step or a programme Set the keypad to switch to ON Set the channel switch to Program The display shows the 1st programme step 0 B Y of G Press the ENTER key repeatedly until the display shows the programme to be erased Press on DELETE the display shows the following programme 3 leg 00 5 step Set the channel switch to Normal position J le j p E 5 The display shows the time of the day Set the keypad switch to OFF To erase a programme completely hold the DELETE key pressed P as a a sees until the display shows Manual controls of channels Set the keypad switch to ON Set the corresponding channel s switch es to Program Press MANUAL key the corresponding channel relay will close and the LED will light up Set the channel switch back to Normal Set the keypad switch to OFF Cut off of channel s programming s Set the channel switch es to STOP position 22 TEST PROGRAMME This test is designed for trouble shooting It can be performed when installing Caution This test cancels all the programming Starting the test programme Remove the cover Disconnect the clock and channels circuits to avoid activation of the equipments Switch on the mains green LED lights up Press 6 times on RESET to display successively Test 1 display Each segme
3. horloges r ceptrices suivant le type d impulsions choisi voir Programmation de la distribution horaire Nota Les impulsions 1 2 minute s rie s obtiennent en ajoutant un rh ostat de r glage d intensit sur la sortie 18 e Brancher les circuits de programmation sur le bornier 15 Si l appareil est pr vu avec Synchro radio brancher l antenne sur le bornier 24 en prenant soin de serrer la tresse du c ble avec l attache pr vue pour assurer une bonne prise la masse Fonctionnement en r cepteur minute ou 1 2 minute brancher la ligne d impulsions sur le bornier 25 entre A et C e Brancher la cosse fil rouge de la batterie La visu affiche Si l affichage est incorrect appuyer sur RESET e Mettre le secteur la LED verte 17 s allume Antenne radio Le Microquartz 6 peut tre synchronis soit sur DCF 77 avec l antenne AD 10 soit sur FRANCE INTER avec le r cepteur FRANCE INTER Choisir l emplacement e le plus haut possible e loign d une paroi m tallique ou en b ton arm e loigne de source de parasites e l abri de la foudre Ouvrir le coffret de l antenne CJ c3 CJ CJ cJ L antenne doit tre perpendiculaire la direction de l metteur ALLOUIS 18 pour FRANCE INTER MAINFLINGEN RFA pour DCF 77 le presse toupe vers le bas L orientation est bonne si e les voyants se trouvant dans l antenne et sur le Microquartz clignotent une fois par s
4. ou les interrupteur s du ou des circuit s concern s en position Programme Appuyer sur la touche Manuel la LED du ou des circuit s commut s s allume pendant le temps d appui Remettre les interrupteurs du circuit en position Normal Mettre l interrupteur clavier sur OFF Coupure de programme s Mettre le ou les interrupteur s des circuits concern s en position STOP 11 PROGRAMME TEST Le programme Test permet de localiser un d faut Il peut tre effectu pr ventivement l installation Attention Ce test peut annuler tous les programmes Lancement du programme test Enlever le capot D brancher les sorties distribution d heure et circuits afin que le test mait pas d effet sur les quipements command s Mettre le secteur la LED verte s allume Appuyer 6 fois sur RESET pour faire appara tre successivement CJ C3 J CJ CJ cJ V Co Co C2 C2 cJ C5 cJ C2 cJ Test 1 Afficheur Chacun des segments appara t successivement sur la visu Gd F E Appuyer sur RESET Test 2 Touches et inter clavier Appuyer sur chaque touche pour faire appara tre le code L L A Un correspondant sur la visu Inter clavier CLA ON OFF Touche seconde 01 Touche Minute 02 Touche marche arr t 03 Touche 1h 04 Touche 1h 05 Touche jour 06 Synchro 07 Valid 08 Effacement 09 Manuel 10 Appuyer sur RESET int i Test 3 Interrupteurs de circuit
5. Bornier batterie 23 Fusible batterie 2A 24 Bornier antenne radio 25 Bornier antenne impulsions mode r cepteur 1 Second advance key 2 Minute advance key 3 Stop Start Synchro pilot LED 4 Clock control key stop start 5 Hour advance key 1 h 6 Hour retard key 1h 7 Weekday setting key 8 Slave clocks synchro key 9 Keypad locking switch 10 Key for manual control of circuits 11 Delete key for programming 12 Enter key for programming o Circuit switches 1 to 6 14 Circuit pilot LED 1 to 6 15 Terminal for circuits 1 to 6 16 Radio reception pilot LED 17 Sector indicating LED 18 Terminal for slave clock ligne 19 Sector connection terminal 20 Transformer connection terminal 21 Microprocessor Reset key 22 Battery terminal 23 Battery fuse 22A 24 Radio antenna terminal 25 Impulse input terminal for slave mode CARACT RISTIQUES TECHNIQUES e Alimentation 220 240 V 50 60 hz option 110 220 V 50 60 Hz e Base de temps a quartz pr cision 0 1 sec par jour entre 20 et 25 C e Synchronisation radio par antenne externe assurant une pr cision absolue long terme et les changements automatiques t hiver Europe seulement e Option r ception d impulsions minute ou 1 2 minute pour placer dans r seau de distribution d heure existant e Changement automatique d heure d t et d hiver programmable jusqu une semaine en avance e Reserve de marche 72 h par m moire avec remise
6. interrupteur clavier sur ON Arr ter l horloge en appuyant sur la touche STOP START la LED rouge 3 s allume Mettre l horloge au jour et l heure exacte l aide des touches jour 1h 1 h min Au TOP horaire appuyer sur Start Stop Le t moin rouge s teint Les secondes fonctionnent Mettre l interrupteur clavier sur OFF Les horloges r ceptrices se synchroniseront automatiquement soit par rattrapage LED clignote soit par attente si elles sont en avance de moins d une heure Le cycle de rattrapage est sur 24 h Nota Il est possible de contr ler l heure des r ceptrices a tout moment pour le 24 V distribution Min 1 2 le SR2 SR3 en appuyant sur la touche VALID pour le D1 D2 et le T l sect en pla ant l interrupteur du circuit 6 13 en mode programme et en appuyant sur la touche VALID Changement d heure Et Hiver Le Microquartz permet d effectuer le changement d heure Et Hiver soit instantan ment soit pr programme e Changement instantan Mettre l interrupteur clavier sur ON Appuyer sur la touche 1 h pour l heure d t ou 1 h pour l heure d hiver Remettre l interrupteur clavier sur OFF e Changement programm Mettre l interrupteur verrouillage clavier sur ON Appuyer sur la touche 1 h t ou 1 h hiver et la maintenir 5 secondes La visu affiche o 0 8 0 gp Entrer le jour heure minute du changement d heure Ex Dimanche 0
7. located below the transformer WARNING The cable should not run behind the printed circuit board e Hole for cables Connections e Connect live phase and earth ground on terminal 19 e Connect the slave clock line s according to the type of impulse selected see master clock set up chapter Note for 1 2 min SERIES impulses add an adjustable resistor on output 18 to regulate intensity e Connect the programming channels on terminal 15 terminal 4 to 6 may be already used for slave clock impulses If the equipment is intended for operation with Radio antenna connect the antenna on terminal 24 taking care of setting the cable shield into the clamp to ensure good earthing Min or 1 2 min reception connect the impulse line on terminal 25 in A and C e Connect the terminal of the battery The display shows if display is incorrect press RESET e Switch on the mains the green LED 17 lights up m Ono Gogo a Radio antenna connection Europe only Microquartz 6 can be synchronized by means of either AD 10 antenna for DCF 77 signal or Fl antenna for FRANCE INTER signal Select the antenna location as follows e As high as possible e Far from any metallic structure or armoured concrete e Far from eventual electric interference sources e Protected from lightning 15 Open the antenna box The antenna must be perpendicular to the transmitter direction A
8. with its controls e After connecting the battery avoid any operation or connection inside the appliance e Change de 12 V battery every 4 years while keeping the mains on in order to avoid losing the programming CONSERVER CE LIVRET DANS L APPAREIL STORE THIS BOOKLET INSIDE THE UNIT DESCRIPTIF FES fos S i f f j N f Le Pi a A i i a z k TA n Z 4 i j pi ji Si Pi E oo es de Te 19 J ae aale oo 0O 18 ol O a ne ET O i 8 ee a a 17 Peet 4 LL of 2 ui j Hga 3 9 ays o rp D y RO a 4 45 14 43 42 11 40 9 8 7 6 5 4 1 Touche avance des secondes 2 Touche avance des minutes 3 T moin marche arr t synchro 4 Touche marche arr t horloge 5 Touche avance heures 1h 6 Touche retard heures 1h 7 Touche avance jour de semaine 8 Touche synchro horloges r cept 9 Inter de verrouillage clavier 10 Touche de commande manuelle des circuits 11 Touche d effacement de la programmation 12 Touche de validation de la programmation n Inter des circuits 1 6 14 T moins des circuits 1 6 15 Bornier de connexion des circuits 1 6 16 T moin de r ception radio 17 T moin de pr sence secteur 18 Bornier de ligne d horloges r ceptrices 19 Bornier raccord secteur 20 Bornier raccord transformateur 21 Touche Reset microprocesseur 22
9. 3 h 00 La visu clignote 4 0 3 0 gp Valider La visu affiche de nouveau lheure normale Replacer l interrupteur clavier sur OFF Pour v rifier l heure du changement programm e proc der comme ci dessus le jour et l heure programm s s afficheront sur la visu PROGRAMMATION DES CIRCUITS Les 6 circuits peuvent tre programm s en mode DUREE sonneries ou en mode MARCHE ARRET Pour programmer un circuit Placer l interrupteur du circuit a programmer en mode PROGRAMME Entrer le jour l heure la minute la dur e ou Marche Arr t l aide des touches JOUR HEURE MINUTE SECONDE La visu clignote les donn es sont en attente Valider La visu devient fixe donn es enregistr es Le choix du mode se fait comme suit e Arr t circuit ouvert D D D D g i e Marche circuit ferm pU p e Dur e 2 59 sec ex 6 sec HA no 5 Si des circuits 4 5 6 sont utilis s en distribution horaire SR3 D1 D2 Telesect ils ne sont pas accessibles pour la programmation Exemple Programmation du circuit 4 C4 en sonnerie Placer l inter clavier sur ON Placer l inter circuit 13 C4 sur programme le premier pas s affiche Programmer dans n importe quel ordre le jour l heure la minute et la dur e du signal Ex Lundi 08 h 45 dur e 5 sec n gH Sgp 5 Valider La visu devient fixe la donn e est enregistr e l 0 8 4 of 5 Pour les
10. INSTRUCTIONS DE MISE EN SERVICE OPERATING INSTRUCTIONS MICROQUARTZ 6 B P 1 49340 TR MENTINES FRANCE T l 02 41 71 72 00 Fax 02 41 71 7201 www bodet com PE ehcp 0 825 06 68 71 R f 604078 G 0 15 min AFAQ N 1997 8075 S assurer r ception que le produit n a pas t endommag durant le transport pour r serve au transporteur Table des mati res 2 RECOMMANDATIONS G N RALES 3 DESCRIPTIF 4 CARACT RISTIQUES TECHNIQUES 5 INSTALLATION 6 PROGRAMMATION DE LA DISTRIBUTION HORAIRE 8 MISE L HEURE 10 PROGRAMMATION DES CIRCUITS 12 PROGRAMME TEST Index 2 GENERAL RECOMMENDATIONS 14 TECHNICAL CHARACTERISTICS 15 INSTALLATION 16 SET UP OF CLOCK SYSTEM 18 SETTING THE TIME 20 PROGRAMMING OF THE CHANNELS 22 TEST PROGRAMME RECOMMANDATIONS GENERALES e S assurer la r ception que l appareil n a pas t endommag dans le transport e Avant la mise en service lire le mode d emploi et se familiariser avec les manipulations e Lorsque la batterie est branch e viter toute manipulation et branchement l int rieur de l appareil e Changer la batterie 12V tous les 4 ans en conservant l alimentation secteur afin de ne pas perdre la programmation GENERAL RECOMMENDATIONS e Upon receipt of the equipment make sure that it has not been damaged during transport e Before setting in operation read the instructions manual and get familiarized
11. LLOUIS F for Fl antenna MAINFLINGEN Germany for DCF and cable joint towards the ground The position is correct if e The LED in antenna box and on Microquartz 6 blinks once per second e The sound in the earphone is clear and disappears once per second AD 10 antenna Fix the antenna on its bracket Close the box taking care of the waterproof joint Note The clock synchronizes itself on time after 5 to 15 minutes However in case of difficult environment it may take as much as 24 h to endure synchronization SET UP OF CLOCK SYSTEM The Microquartz 6 is designed to operate various types of time systems using the slave clock ling output and 1 2 or 3 channels of the programmer The unit is delivered from the factory adjusted for 1 min 24 V reverse polarity In order to obtain other types of impulses operate as indicated using the 3 keys RESET SECOND and ENTER remove the cover set the keyboard switch to ON O Oo U OU T LO press 4 times on RESET key The display shows p p 0 n PO Selection of the clock system type ine on Type of impulses Output terminal isplay 18 po gg Minute 24 V polarized ZH pe 18 po o4 1 2 minute 24 V or serial ZA Le TEE PC po op SR2 hourly supervision 59 2 wires abe 8 C 18 Po o3 SRS hourly supervision 59 2 wires K Te E B Code on Type of impulses Output terminal
12. NNELS The 6 channels can be programmed in TIMER MODE bells or in ON OFF mode To program a channel Set the corresponding channel switch to Program mode Key in the day hour minute signal duration or ON OFF by means of the day hour minute and sec keys The display blinks data are on stand by Enter the display becomes still data are recorded The mode selection is done as follows e OFF open circuit HEHH u e ON closed circuit l n nnp p e TIMER 2 to 59 sec EG 6 sec i GOoaggs If channels 4 5 6 have been preset for SR3 D1 D2 Telesect or sync wired slave clock systems they are not accessible for programming Example Programming of channel C4 for bells Set the keypad switch to ON Set the channel C4 13 switch to Program If the channel already contains a programme the first program step Co CQ Ae Ln Co Wn is displayed Set the signal day hour min and duration in any order EG Monday 08 H 45 duration 5 sec f DE Uu 5 0 G Enter The display becomes still the data are recorded For other steps proceed as above After programming is terminated e Set the channel switch C4 13 to normal e Set the keypad switch to OFF Reading the programme Set the keypad switch to ON Set the circuit switch to Program The display shows the ha programme step Press the ENTER key repeatedly to display the programme until the display shows
13. SU 220 T l sect impulsions 220 V 4 fils 06 minute 24 V FH T l sect impulsions 220 V 4 fils 4 3 5 ie Je Y minute 24 V Synchronous wired inutilis en PO 08 Europe Exemple Impulsions minute 24V D1 D2 Code PO 04 po 0 u Appuyer 4 fois sur la touche seconde pour afficher Valider La visu affiche p J P1 Choix de la dur e d impulsion La dur e des impulsions min 1 2 min ou SR2 SR3 est r glable de 1 P i 13 1 8 Elle est livr e en standard r gl e sur 1 3 sec Appuyer sur la touche Seconde pour afficher la dur e d sir e p iB ex 1 8 Valider La visu affiche P2 Mode de fonctionnement re ug Pour le Microquartz 6 toujours valider Pour le Microquartz 6 R R cepteur choisir le mode de fonctionnement Ind pendant Pe ug R cepteur d impulsions minute Pe gi R cepteur d impulsions 1 2 minute P o2 Valider P3 Choix du mode de synchro radio il faut avoir valid P2 00 P3 00 Heure officielle mise par DCF 77 ou FRANCE INTER P3 1 R seau horaire en avance d une heure sur DCF ou FI P3 Synchro sans changement t hiver P3 1 R seau horaire en retard d une heure sur DCF ou FI Valider la visu affiche le 1er pas de programme r alis la programmation est termin e Contr le du programme Appuyer successivement sur la touche VALIDATION p
14. autres pas de programme proc der comme ci dessus Une fois la programmation termin e Placer l interrupteur C4 13 sur Normal Placer l interrupteur clavier sur OFF Le programme est alors imm diatement ex cut V rification d un programme Placer l interrupteur clavier sur ON 084505 Placer l interrupteur du circuit sur Programme La visu affiche le premier pas du programme gt ee Appuyer successivement sur Valid pour afficher les pas de programme jusqu ce que la visu affiche Placer l interrupteur circuit sur Normal Placer l interrupteur clavier sur OFF Effacement d un pas de programme ou d un programme Placer l interrupteur clavier sur ON Placer l interrupteur du circuit sur Programme La visu affiche le premier pas de programme H 08 4 oo 5 Appuyer successivement sur Valid jusqu afficher le pas de programme effacer 3 CU0U0S Appuyer sur EFFACEMENT La visu affiche le pas suivant J le j 00 5 Placer l interrupteur du circuit sur Normal La visu affiche l heure Placer l interrupteur clavier sur OFF Pour effacer tout un programme maintenir la touche EFFACEMENT jusqu ce que la visu affiche Puis valider L appui sur une autre touche annule la demande d effacement de la totalit du programme Commande manuelle des circuits Mettre l interrupteur clavier sur ON Mettre le
15. econde e Le son l couteur est net et s il dispara t une fois par seconde antenne AD10 Fixer l antenne sur son support Fermer l antenne en faisant attention a l tanch it de la bo te Nota L horloge se synchronise automatiquement apres 5 a 15 minutes toutefois en cas d environnement difficile la synchronisation peut n cessiter jusqu a 24 heures PROGRAMMATION DE LA DISTRIBUTION HORAIRE Le Microquartz 6 permet de r aliser divers types de distribution horaires par utilisation de la sortie ligne d horloges et de 1 2 ou 3 circuits de programmation L appareil est livre regl sur Impulsions minute 24V Pour obtenir d autres types d impulsions programmer en utilisant les 3 touches RESET SECONDES et VALIDATION Enlever le capot Placer l interrupteur du clavier sur ON Appuyer 4 fois sur la touche RESET La visu affiche p 0 0 i PO choix du type d impulsion de distribution horaire Code sur Type d impulsion Bornier de sortie VISU i z 18 po oo Minute 24 V polaris J9 8 i yoa 18 po oq 1 2 minute 24 V ou s rie R 8 T PC po op SP2 recalage horaire 59 2 fils ab 8 i 18 po o3 SRS recalage horaire 59 3 fils T 2 i B po o4 D1 D2 impulsions min 220 V 3 N fils minute 24 V su D1 D2 impulsions min 220 V 3 D1 PE 93 fils 1 2 minute 24 V gt G Code sur Type d impulsion Bornier de sortie VI
16. l heure des cadrans apr s coupure secteur e Sauvegarde du programme plusieurs jours en cas de coupure secteur e 1 sortie d horloges r ceptrices impulsions minute 24 V ou 1 2 minute sur SR2 59 ou SR3 a programmer 1A e 6 circuits programmables de minute en minute en mode marche arr t ou dur e sur une semaine Capacite 4A 240 VAC Capacit de programmation 127 pas par circuit Commandes manuelle marche arr t pour chaque circuit Ces circuits permettent par programmation de r aliser les distributions horaires suivantes D1 D2 220 V 3 fils T l sect 4 fils SR3 Sync wired e Temp rature de fonctionnement 0 50 C e Poids 3 4 kg g 2 2 ma E E ec S 5 f FE 9 2 py 9 2 22 S 2s GE 1 OO Vers horloge r ceptrice TZ A Vers circuits O 8 o O m ms O co Vers circuits o ao O O O O QO o HO O INSTALLATION LE 316 e Choisir un local faibles variations de temp rature et loign de toute q source de parasites lectriques y contacteurs moteurs Vue de face e Fixer l appareil au mur capot enleve e Passer les cables lectriques par ouverture situ e sous le transformateur ATTENTION Les cables ne doivent pas passer derri re le circuit LY N lt ___ passage des cables TX BRANCHEMENT e Brancher phase neutre TERRE sur le bornier 19 e Brancher la ou les ligne s d
17. mmer winter time changeover Europe only e Option operation as slave clock on minute or 1 2 minute system e Outputs 1 slave clock line 1 A 24 V minute impulses duration 1 3 sec adjustable to 1 2 minute or SR2 or SR3 by programming 6 channels with relays contact rating 4 amp 240 VAC programmable in Timer mode from 2 to 59 sec ON OFF mode from 1 min to 7 days Impulses for slave clocks The type of impulses programmable on the channels are 220 V 3 wires 1 min impulse for tower clocks D1 D2 impulses 220 V Telesect 4 wires impulses SR3 3 wires impulse system with hourly supervision Sync wired hourly and 12 hour correction system e Programming cycle 1 week e Accuracy of programming minute to minute e Programming capacity 127 steps per channel e Channel controls manual automatic off e Summer winter time changeover programmable up to 1 week in advance e Operating temperature O to 50 C e Weight 3 4 kg 5 c 5 S gt amp 7 2 2 2 8 g S g a O a To slave clocks 1 To circuits O Zis Ol O O cc cr roca F 9 e000 g o HE Oo INSTALLATION LE 316 e Select a location with minimal temperature variations and far from q J 4 any electrical interference source P D relays motors Front view e Fix the Microquartz on the wall cover removed e Run all cables through the opening
18. nt is displayed successively Press RESET Test 2 Keypad keypad switch on ON Each key has a code number which is displayed when pressed Key Keypad switch Second key Minute key Stop start key 1 hour key 1 hour key Day key Synchro Enter Delete Manual Press RESET code ON OFF 01 02 03 04 05 06 07 08 09 10 Co CJ alis co Ca C2 C2 Co C3 CI GGUaod 00 CLA Un link Test 3 Channel switches Each channel switch when activated is displayed as follows Normal Program Stop Press RESET Test 4 Power supply Radio Impulse reception 1 indicates presence blinking for radio 0 indicates absence Press RESET Test 5 Slave clock circuit This test delivers fast impulses on clock circuit output 18 Check with voltmeter Press RESET Test 6 Channel relays Each relay is activated successively Check contact with ohmmeter Press RESET Test 7 Memory link PI hank Ci Impulse input Radio synchro Mains hor rI PAG This test checks the 16 memory pages after a 5 sec Stand by Caution This test erases the data contained in the memory To avoid losing the data press RESET before the test starts END OF TEST C2 C2 C2 CJ cJ 23 24
19. our afficher les pas de programme Sortie du programme l NANA Appuyer sur la touche RESET La visu affiche I LU VU wo LI Nota Si l on appuie une nouvelle fois sur la touche RESET on entre dans le programme TEST voir P 11 Pour revenir au programme DISTRIBUTION HORAIRE d marrer horloge puis l arr ter touche Start Stop puis appuyer 4 fois sur la touche RESET MISE L HEURE Mise l heure de la distribution horaire Si la distribution horaire est programm e pour commander 2 r seaux de r ceptrices s par s la mise l heure de chaque r seau se fait de mani re ind pendante pour permettre le recalage de l un par rapport l autre R seaux Minute 24 V 1 2 minute SR2 SR3 Mettre toutes les r ceptrices la m me heure Enlever le capot du Microquartz Placer l interrupteur clavier sur ON Arr ter l horloge en appuyant sur la touche Stop Start le t moin rouge s allume Mettre le Microquartz l heure indiqu e par les r ceptrices l aide des touches 1h 1h min Appuyer sur la touche Stop Start Le t moin rouge s teint Appuyer imm diatement sur la touche Synchro 8 Les r ceptrices sont synchronis es Mettre l interrupteur clavier sur OFF R seaux D1 D2 Telesect Placer l interrupteur C 6 13 en position programme puis proc der comme ci dessus Remettre l interrupteur C6 13 en position normal Mise l heure du Microquartz Mettre l
20. s Chaque interrupteur affiche Normal Program int P Stop ine C Appuyer sur RESET Test 4 Pr sence Secteur Radio R ceptrice impulsion 1 indique la pr sence clignote pour radio Entr e impulsion 0 indique l absence Radio Secteur Appuyer sur RESET Test 5 Circuit horloge Contr ler la pr sence d impulsions sur le bornier 18 l aide d un hor voltm tre Appuyer sur RESET Test 6 Relais circuit 1 6 r i Les relais 1 6 sont activit s successivement et la LED s allume V rifier le contact avec un ohmmetre Appuyer sur RESET Test 7 M moire PAG Ce test v rifie les 16 pages m moire apr s une temporisation de 5 secondes Attention Ce test efface toutes les donn es contenues en m moire Pour viter de perdre ces donn es appuyer sur RESET avant le d marrage du test Appuyer sur RESET FIN DU TEST CJ C2 Ci CJ CJ cJ 13 14 TECHNICAL CHARACTERISTICS e Power supply 220 240 V 50 60 Hz or 110 120 V 50 60 Hz e Power reserve over 72 h by electronic memory providing automatic resetting of slave clocks as soon as the mains is re established e Quartz Time base accuracy 0 1 sec day between 20 and 25C e Radio synchronization by means of external antenna providing absolute long term accuracy and automatic su
21. s 1 hour Enter The display shows the ist programme step entered The programming is completed Programme control Press successively on ENTER to display the programme steps Programme exit noonon U GLI LL L Wea Press the RESET key The display shows Note A further press on the RESET key will open the TEST programme see P 20 To re enter the set up programme start the clock then stop it Start Stop key and then press the RESET key 4 times SETTING THE TIME Clock system start up If the master clock has been set up to control 2 separate slave clock circuits setting the time of each circuit is done independently to allow for the reset of one circuit only Clock circuit 24 V minute 1 2 minute SR2 SR3 Set all slave clocks on the same time Remove the cover of the MICROQUARTZ Set the keyboard switch to ON Stop the clock by pressing the Stop Start key the pilot Led lights up Set the Microquartz to the time shown on the slave clocks by means of the 1h 1h minute keys Start the clock by pressing the Stop Start key the pilot LED switches OFF Immediately press the synchro key the slave clocks are now synchronized Set the keyboard switch to OFF Clock circuit D1 D2 3 wires Telesect 4 wires Set the channel 1 switch C6 13 on programme position then proceed as above Replace switch C6 in normal position Setting the time of the Microquartz Set the keyboard swi
22. tch to ON Stop the clock by pressing the Stop start key the red LED lights up Set the clock to the exact day and time using the 1 h 1 h min keys On the time signal press the Start Stop key the red LED switches OFF the second start counting Set the keyboard switch to OFF The slave clocks will synchronize themselves automatically either catching up or in stand by if they are ahead less than 1 h catching up cycle is 24 h Note It is possible to check the slave clocks time at any time for min 24 V 1 2 min 24 V and SR2 SR3 by pressing the enter key for D1 D2 and Telesect by setting the channel 6 13 switch to program and pressing the enter key SEASONAL TIME CHANGE Seasonal time changes can be performed instantly or preset up to 1 week in advance Instant time change Set the keypad switch to ON Press briefly the 1 h for summer time and 1 h for winter time Set the keypad switch to OFF Preset time change Set the keypad switch to ON Press the 1 h summer time or 1 h winter time key and hold it for 5 sec until the display shows Enter the day and time of the changeover 0 au a D EG Sunday 03h00 the display blinks Press ENTER key q U 700 The display shows the tiem of the day again Set the keypad switch to OFF To check time of the changeover proceed as above the preset day and time will be displayed 19 PROGRAMMING OF THE CHA
Download Pdf Manuals
Related Search
Related Contents
McIntosh MA6600 audio amplifier Descargar Ficha de Productos CONTEC Handbuch STEALTHcam (application/pdf) - The Toughphone TE- 300/500W –WV Series Inverters User Manual Bosch 2609255313 Cobra Electronics HH300 User's Manual SCIROCCO - Pennine Tea and Coffee Company MANUAL DE USUARIO - Besøg masterpiece.dk Copyright © All rights reserved.