Home

Samsung AST18P0GEA User Manual

image

Contents

1. Adjusting the Air Flow Direction Horizontally T O 2 LI There are two sets of inner air flow blades Just as the outer air flow blade can be adjusted vertically the inner blades can be adjusted horizontally 1 Adjust each set of inner blades to the required position by pushing or pulling them sideways Setting the On Timer oee 1 er Or Dl S Hr The On Timer enables you to switch on the air conditioner automatically after a given period of time You can set the period of time from 30 minutes to 24 hours On To set the operating time press the ME button one or more times until the required time is displayed Possible time is between 0 5 hour and 24 hours inclusive Timer Press the 3 Set Cancel button to complete the setting The remaining time is displayed Blinking of the timer indicator stops The selected mode and the temperature on the display disappear after 10 seconds The air conditioner will switch on automatically when the counter displayed on the remote control reaches the set time and disappears the On timer setting Result To select an operating mode in advance press the button until the desired mode is displayed at the top of the remote control Result The air conditioner will run in the selected mode when it is turned on To Cancel the On Timer Timer 4 If you press the cm b
2. Fat Timer Timer Set Cance Gs Am En U Kd ky D O D O UU On Off Timer Timer Timer Set Cancel CO GQ 5e Setting the Sleep Timer N On On Timer Timer Seta ee Sash The Sleep Timer can be used when you are cooling your room to switch the air conditioner off automatically after a period of 6 hours Note If you wish to switch the unit off at a specific time refer to page 19 1 Make sure that you have selected the COOL mode 2 Press the button CJ Result 4 The indoor unit beeps The air conditioner will be controlled as indicated in the illustrations below Cooling The desired temperature is increased by 1 C every hour When it has been increased by 2 C after 2 hours the temperature is maintained for four hours To Cancel the Sleep Timer If you no longer wish to use the Sleep Timer that you have set you can cancel it at any time Press the ey button Result 4 The indoor unit beeps The 2 is no longer displayed The air conditioner operates normally Operating Recommendation T O 2 LI Here is a recommendation that you should follow when using your air conditioner Topic Recommendation Power failure If a power failure occurs when the air conditioner is operating the unit is switched off When the power returns the air conditioner starts up again automatically Temperature and Humidity Ranges The fo
3. CD button again Result The air conditioner is reset automatically to the previous mode temperature and fan settings 4 To control the direction of the air flow refer to pages 16 and 17 Removing Excess Humidity If the atmosphere in your room is very humid or damp you can remove excess humidity without lowering the room temperature too much 1 If necessary press the On Off button Result The air conditioner starts up in Cool mode with Turbo fan speed The operation indicator on the indoor unit lights up The indoor unit beeps fora PORTANT The air conditioner is fitted with a protection mechanism to prevent the unit from being damaged when it is started A EEE immediately after being Plugged in Stopped It will start up normally after three minutes lt a a p gt 2 Ifthe CP is not displayed at the top of the remote control press the button on the remote control one or more times until it appears Result 4 The indoor unit beeps each time you press the button The air conditioner runs in DRY mode Note You can change modes at any time 7 L Mode tal 1 On Off FR CP 3 To adjust the temperature press the button one or more times until the required temperature is displayed Possible temperatures are between 18 C and 30 C inclusive BS Result 4 Each time you press the button C fr The temperature is adjusted by 1 C The indoor unit beeps 4 The air conditioner star
4. KRR KRR KK KRR KKK KRR K KRR KKK KRR KKKRKK KI You have just purchased a split type air conditioner and it has been installed by your installation specialist Your Owners Instructions contains valuable information on using your air conditioner Please take the time to read it as it will help you take full advantage of the unit s features The booklet is organized as follows The following figures are shown on pages from 4 to 6 Indoor and outdoor units Remote control buttons and display They will help you find the buttons and understand the symbols displayed In the manual you will find a series of step by step procedures for each function available The illustrations in the step by step procedures use three different symbols HOLD DOWN Inserting the Remote Control Batteries You must insert or replace the remote control batteries when You purchase the air conditioner The remote control does not work correctly Note Use two AAA LRO3 1 5V batteries Do not use old batteries or different kinds of batteries together Batteries may be completely discharged after 12 months even if they have not actually been used 1 Push the battery cover on the rear of the remote control with your thumb in the direction of the arrow and remove it 2 Insert the two batteries taking care to respect the polarities on the battery with on the remote control 4 on the battery with on the remote control 3
5. Close the cover by sliding it back until it clicks into place Selecting the Automatic Operating Mode You can start the air conditioner in Automatic mode from your remote control In the Automatic mode the optimum temperature and the fan speed is selected automatically 1 If necessary press the On Off button Result The air conditioner starts up in Cool mode with Turbo fan speed The operation indicator on the indoor unit lights up The indoor unit beeps PORTANT The air conditioner is fitted with a protection mechanism to prevent the unit from being damaged when it is started immediately after being Plugged in Stopped It will start up normally after three minutes 2 Ifthe Kano is not displayed at the top of the remote control press the button on the remote control one or more times until it appears Mode Result The indoor unit beeps each time you press the button The air conditioner runs in AUTO mode Note You can change modes at any time T O Z Lu 4 oro Mode Digital On Off NATURAL Wy CA ital 7 On Off Cooling Your Room You must select the Cool mode if you wish to adjust the Cooling temperature Fan speed when cooling 1 If necessary press the On Off button Result 4 The air conditioner starts up in Cool mode with Turbo fan speed The operation indicator on the indoor unit lights up The indoor unit beeps fora PORTA
6. Do not spray liquid of any kind into the indoor unit Should this happen switch off the breaker used for your air conditioner and contact your installation specialist Make sure that the unit is correctly ventilated at all times Do not place clothing or other materials over it If the wireless remote control will not be used for a long time remove the batteries If applicable When using a wireless remote control the distance should not be more than 7 meters from the air conditioner lf applicable Before throwing out the device it is necessary to pull back the battery cells and get rid of them safely for recycling reasons When you need to dispose of the unit consult your dealer If pipes are removed incorrectly refrigerant may blow out and come into contact with your skin causing injury Releasing refrigerant into the atmosphere also damages the environments Please recycle or dispose of the packaging material for this product in an environmentally responsible manner Never store or ship the air conditioner upside down or sideways to avoid damage to the compressor The appliance is not intended for use by young children or infirm persons without supervision Young children should be supervised to ensure that they do not play with the appliance Max current is measured according to IEC standard for safety and current is measured according to ISO standard for energy efficiency Contents PREPARING YOUR AIR CONDITIONER
7. NT The air conditioner is fitted with a protection mechanism to Mode Digital On Off prevent the unit from being damaged when it is started immediately after being Plugged in Stopped It will start up normally after three minutes OO TEKS 2 Ifthe WH is not displayed at the top of the remote control a V me Mode Hl m l press the O button on the remote control one or more times until it appears Result 4 The indoor unit beeps each time you press the button The air conditioner runs in COOL mode LY wu Mote You can change modes at any time Mode tal 7 On Off Ta 3 To adjust the temperature press the button one or more times until the required temperature is displayed Possible temperatures are between 18 C and 30 C inclusive F Result 4 Each time you press the button Gea ec gt The temperature is adjusted by 1 C The indoor unit beeps The air conditioner starts cooling provided that the room temperature is higher than the selected temperature If the room temperature reaches the set temperature the air conditioner stops cooling but the fan is still operating 4 Select the fan speed by pressing the By button one or more times until the required setting is displayed Gas Automatic rotated gt PKR gt Ke lt Low amp Medium a High Ga Turbo maximum Result Each time you press the button the indoor unit beeps 5 To contr
8. OWNER 5 INSTRUCTIONS MANUAL DE INSTRUCCIONES 8 MANUEL D UTILISATION Indoor unit Outdoor unit AST12P4GB UST12P4GB E AST12P4GE UST12P4GE z AST18POGBA UST18POGBA A AST18POGEA UST18POGEA 5 AST24P6GBA UST24P6GBA AST24P6GEA UST24P6GEA a lt O Z lt or LL Split type Room Air Conditioner Cool Aire acondicionado dom stico sistema Split Refrigeraci n Climatiseur de type S par Refroidissement BOBA DB98 16557A 1 Safety Precautions The following safety precautions must be taken when using your air conditioner N WARNING DURING OPERATION DISPOSING OF THE UNIT OTHERS Risk of electric shock Can cause injury or death Disconnect all remote electric power supplies before servicing installing or cleaning e This must be done by the manufacturer or its service agent or a similar qualified person in order to avoid a hazard Users of this product are cautioned not to attempt repair of this product at their own discretion Instead they are requested to directly contact a designated service center or the outlet at which the product was purchased Never spill any kind of liquid into the unit Should this happen unplug or main switch off the unit and contact an authorized service center Do not insert anything between the air outlet blades because the inner fan may be damaged and could cause injury Keep children away from the unit Do not place any obstacles in front of the unit
9. Result The air conditioner starts up in Cool mode with Turbo fan speed The operation indicator on the indoor unit lights up The indoor unit beeps Fora PORTANT The air conditioner is fitted with a protection mechanism to Mode Digital On Off prevent the unit from being damaged when it is started immediately after being Plugged in Stopped It will start up normally after three minutes 2 Select COOL mode by pressing the button Note You can select the Energy saving mode only in the COOL mode 5 H 3 Press the oe button Result 4 The indoor unit beeps The air conditioner runs in the Energy saving mode 4 The outer air flow blade moves up and down To stop the Energy saving mode press the pe button again 4 To adjust the temperature press the button one or more times until the required temperature is displayed Possible temperatures are between 26 C and 30 C inclusive Note If you want to adjust temperature under 26 C cancel the Energy saving mode before adjusting the temperature 5 To select the fan speed press the PEN button one or more times until the required setting is displayed Ga Q c y 6 To control the direction of the air flow refer to pages 16 and 17 ESC Generating Anion T O 2 LI The air conditioner can generate anion with an onizer in the indoor unit Since it is an additional function you can select it any mode even when t
10. erations can still be controlled using the remote control as usual Solving Common Problems I 2 O 2 Li Before contacting the after sales service perform the following simple checks They may save you the time and expense of an unnecessary call Problem The air conditioner does not operate at all The air conditioner does not operate with the remote control No beep is heard when you press the On Off on the remote control The air conditioner does not cool The fan speed does not change when you press the B button The air flow direction does not change when you press the button The timer is not correctly triggered Odour is permeated in the room during air conditioning Explanation Solution 4 Check that the breaker used for the air conditioner is switched on Check that the operation indicator on the indoor unit is on if necessary press the On Off button on the remote control Check whether the Timer indicator on the indoor unit is switched on If so Wait until the switch on time is reached and the air conditioner starts up automatically Cancel the timer See pages 18 and 19 for further details Check that there are no obstacles between you and the indoor unit 4 Check the remote control batteries Check that you are close enough to the indoor unit seven meters yards or less Check that you are pointing the remote control at the remote control sensor in the right o
11. et Room temperature sensor Air filter sg blades outlet Set temperature amp Timer ER Room temperature Sleep Timer indicator a Anion indicator Fan speed setting Al Note If you want to turn on off the display during operation press the E5 button on the remote control The room temperature sensor senses air temperature around the sensor and shows the temperature on the display o T Z LI Air Inlet Rear Air Outlet Connection Valve UST18POGBA UST18POGEA UST24P6GBA UST24P6GEA Air Inlet Rear Air Outlet Connection Valve Remote Control Buttons and Display Remote control transmission indicator Battery discharge indicator Fan speed Anion indicator Sleep mode On Off button Mode selection button AUTO COOL DRY FAN Fan speed adjustment button Turbo button On Timer button Off Timer button A Operating mode Lave AUTO amp COOL G DRY FAN Turbo mode Gaa H oe Olalla NATURAL Temperature setting Air flow direction Off Timer setting Energy saving Temperature adjustment buttons Digital On Off button Swing button Energy saving button Timer Set Cancel button Sleep button Anion button I D O 2 Li Getting Started SKRR KR KRR KRR KRRR KRR KRR KRR KRR KRR KRR KRR KRR KKK KRR KRR KK KRR KKK KRR KRR KRR
12. f the indoor unit Replace the remote control batteries if necessary Check that the correct operating mode has been selected AUTO COOL 4 The room temperature may be too low Dust may be blocking the air filter guard refer to page 24 for cleaning instructions Check that there is no obstacle in front of the outdoor unit Check that the operating mode is set to COOL or FAN in the AUTO mode the fan speed changes automatically and in the DRY mode it is set to AUTO Check that the air conditioner has been switched on if necessary press the On Off button on the remote control Check that the timer has been programmed correctly see pages 18 and 19 Air the room Cleaning Your Air Conditioner For the best use of your air conditioner you must clean it every two weeks regularly to remove the dust that accumulates on the air filter PORTANT Before cleaning your air conditioner ensure that you have switched off the breaker used for the unit 1 Slide the lower front grille down 2 Open the upper front grille by pulling right and left sides of the grille 3 Disassemble the upper front grille by opening the grille completely 4 Lift out the bottom edge of the air filters and pull down to release them 5 Remove all dust on the air filters with a vacuum cleaner or brush 6 When you have finished insert the top part of the filters into their slot and push down on the bottom edge unti
13. he air conditioner is turned off 1 Press the ZS button CJ Result 4 The air conditioner generates anion The indoor unit beeps o Note If you press the gt button during off the air conditioner will turn on automatically and generate anion in the Fan mode with Low fan speed Le ey 2 If you wish to stop the Anion function press the button again Ou Result The air conditioner is reset automatically to the previous mode D temperature and fan settings Y On Off Timer Timer Timer Set Cancel CJ CJ 3 To control the direction of the air flow refer to pages 16 and 17 E A Adjusting the Air Flow Direction Vertically Depending on the position of the indoor unit on the wall of your room you can adjust the position of the outer air flow blade on the bottom of the unit thus increasing the efficiency of the air conditioner 1 Press the O Result The outer blade is adjusted vertically button one or more times as required RECOMMENDATION When Adjust the blade to face Cooling Upwards 2 If you want the blade to move up and down automatically when the air conditioner is operating press the 5 button Result The blade move up and down around the base position set 3 To stop the blade moving up and down press the 5 button again Mote If you switch the air conditioner Then the blade is Off Closed completely On again Set to the initial position powered
14. l they click into place 7 Clean the front grille with a damp cloth and mild detergent do NOT use benzene solvents or other chemicals 8 Fix the left side of grille support then insert the right side of grille support Note If you have not used the air conditioner for a long period of time set the fan going for three to four hours to dry the inside of the air conditioner thoroughly Body groove 4 To close the upper front grille completely after cleaning filters turn on and turn off the air conditioner Cleaning Deodorizing and Bio Green Filters Option K 2E To remove minute dust particles and odors deodorizing and Bio Green filters are installed in the air conditioner You should clean the filters every 3 months 1 Open the upper front grille by pulling right and left sides of the grille 2 Pull out the deodorizing and Bio green filters Bio Green Filter Deodorizing Filter 1518 24 3 Wash the filters with clean water then dry them in the shade Bio Green Filter 4 Insert the filters into the original position Note You can change the position of filters with each other 5 Close the front g
15. llowing table indicates the temperature and humidity ranges within which the air conditioner can be used If the air conditioner is used at Then High temperatures The automatic protection feature may be triggered and the air conditioner stopped Low temperatures A water leak or some other malfunction may occur if the heat exchanger freezes High humidity levels Water may condense on and drip from the surface of the indoor unit if it is used for long periods Mode Outdoor Temperature Indoor Temperature Indoor Humidity Cooling 21 C to 54 C approx 18 C to 32 C approx 80 or less Drying 18 C to 54 C approx 18 C to 32 C approx Ifthe cooling operation is used at over 33 C indoor temperature it does not cool at its full capacity Operating Your Air Conditioner Without the Remote Control Your air conditioner can be operated directly from the indoor unit if the remote control is lost or broken 1 Slide the lower front grille down 2 To switch the air conditioner on press the On Off switch on the right side of the indoor unit Result 4 The Operation indicator on the indoor unit comes on The indoor unit beeps The air conditioner starts up in the most suitable mode for the room temperature Room Temperature Operating Mode 21 C or above Cool 3 To switch the air conditioner off press the On Off switch again Note Even if the air conditioner has been switched on via the On Off switch op
16. m Safety Precautions lt lt 22x65 vesten osado 2 m View of the Unit 4 Remote Control Buttons and Display 6 m Getting Started nennen 7 m Inserting the Remote Control Batteries 8 OPERATING YOUR AIR CONDITIONER m Selecting the Automatic Operating Mode 9 m Cooling Your ROOM ennn went edes eii 10 m Changing the Room Temperature Quickly 11 m Removing Excess Humidity o oooooooo 12 m Airing Your ROOM sanasana anaana 13 m Selecting Energy Saving Mode nnn 14 m Generating ANION 0 6 ee eens 15 m Adjusting the Air Flow Direction Vertically 16 m Adjusting the Air Flow Direction Horizontally 17 PROGRAMMING YOUR AIR CONDITIONER m Setting the On Timer ss2ssaisasssanaanaaaaa 18 m Setting the Off Timer 0 0 00 19 m Setting the Sleep Timer 2 0 00 20 RECOMMENDATIONS FOR USE m Operating Recommendation annen 21 m Temperature and Humidity Ranges 22 m Operating Your Air Conditioner Without the Remote Control 22 m Solving Common Problems sne arn des brem dann wad 23 m Cleaning Your Air Conditioner ennn 24 m Cleaning Deodorizing and Bio Green Filters option 24 TECHNICAL SPECIFICATIONS I D O 2 Li View of the Unit The design and shape are subject to change according to the model In It Auto grille Air Inl
17. ol the direction of the air flow refer to pages 16 and 17 web PL Note If you turn off the air conditioner in Cool mode the set temperature O CO is adjusted as below when you turn on the air conditioner again Previous set temperature Set temperature Over 24 C 24 C Below 24 C Previous set temperature Changing the Room Temperature Quickly I D O 2 Li The Turbo cooling function is used to cool your room as quickly as possible Example You have just come home and find that the room is very hot You wish to cool it down as quickly as possible The Turbo function operates for 30 minutes with the maximum settings before returning automatically to the mode and temperature previously selected 1 If necessary press the On Off button Result The air conditioner starts up in Cool mode with Turbo fan speed The operation indicator on the indoor unit lights up The indoor unit beeps Ma TURBO 2 Press the O button Result The temperature and fan settings are adjusted automatically The air conditioner cools the room as quickly as possible After 30 minutes the air conditioner is reset automatically to the previous mode temperature and fan settings But if you press the H button in DRY or FAN mode it will change to AUTO mode automatically Off Timer Timer Timer Set Cancel 3 If you wish to stop the Turbo function before the end of the 30 minute period press the
18. rille Deodorizing Filter Technical Specifications T O 2 LI Model Indoor unit Power Supply AST12P4GB AST18POGBA 220V 60Hz AST24P6GBA AST12P4GE AST18POGEA 220 240V 50Hz AST24P6GEA THIS AIR CONDITIONER IS MANUFACTURED BY ESTE AIRE ACONDICIONADO HA SIDO FABRICADO POR CE CLIMATISEUR EST FABRIQUE PAR a ELECTRONICS Printed in Korea
19. ts removing the excess humidity the quantity of air is adjusted automatically 4 To control the direction of the air flow refer to pages 16 and 17 a Mode Digital 1 On Off Airing Your Room T O 2 LI If the atmosphere in your room is stale you can air the room using the Fan feature 1 If necessary press the On Off button Result The air conditioner starts up in Cool mode with Turbo fan speed The operation indicator on the indoor unit lights up The indoor unit beeps J ca Mode Digital On Off 2 lf the K is not displayed at the top of the remote control press the button on the remote control one or more times until it appears Result The indoor unit beeps each time you press the button So The air conditioner runs in FAN mode FF gt 4 The temperature is set automatically Note You can change modes at any time 3 Select the fan speed by pressing the E button one or more times until the required setting is displayed L7 y Mode ye On Off o Low Ga _ Medium Ga High do Result Each time you press the button the indoor unit beeps gt i 4 4 To control the direction of the air flow refer to pages 16 and 17 Selecting Energy Saving Mode If you wish to save energy when using your air conditioner select the Energy saving mode with the Energy saving button 1 If necessary press the On Off button
20. utton when the Off Timer is set the Off Timer is also cancelled Timer Press the Set Cancel Set Cancel button C Note Setting the Off Timer The Off Timer enables you to switch off the air conditioner automatically after a given period of time You can set the period of time from 30 minutes to 24 hours Off 1 To set the operating time press the a button one or more times until the required time is displayed Possible time is between 0 5 hour and 24 hours inclusive 2 Press the o Set Cancel button to complete the setting Result The remaining time is displayed Blinking of the timer indicator stops The air conditioner will switch off automatically when the counter displayed on the remote control reaches the set time and disappears the Off timer setting Example If you would like to turn the air conditioner on after 2 hours and to operate it for 2 hours 1 Press the button until 2 0 Hr is displayed 2 Press the sai Set Cancel button 3 Press the Es button until 4 0 Hr is displayed 4 Press the Set Cancel button Note You can see or change the setting mode and or the temperature by pressing the button or the button after setting the Off timer To Cancel the Off Timer Timer Press the Set Cancal Set Cancel button sena Note If you press the 53 button when the On Timer is set the On Timer is also cancelled T O 2 LI Gea gt gc per