STK-3302PET PIR Motion Detector INSTALLATION MANUAL
Contents
1. Canadian Electrical Code BACK 12 2 COVER PIN FIG 2 BACK TOP VIEW FIG 3 POWER INPUT 12VDC ANTI TAMPER SWITCH The detector comes equipped with the pet immunity PET 2 lens For more information on the full range of lenses ask your local distributor for details If another lens pattern is required choose the desired lens and a remove front cover of the detector 1 by gently pushing in the cover pin 2 with a screwdriver b pull out the bezel 4 by lightly pressing on bezel pins 5 and 6 c remove the lens and replace it with the alternate lens COVERAGE ADJUSTMENT Using the standard lens at the recommended installation height of 2 1m 7ft 10 the 3302PET will provide full coverage from 1 2m 4ft to 11m 35ft at 20 C Please ensure that the PCB is fixed at the 2 1m 7ft mark A small vertical adjustment of the PCB 0 5mm may be required Refer to FIG 4 on other side For any of the other lenses please refer to pattern drawings for each lens If another installation height is called for move the PCB to the proper installation height indicated on the left side of the PCB A small adjustment may be required depending on the protected area Any PCB adjustment should be followed by a walk test of the protected area Walk testing verifies that the required coverage is in place as per the lens pattern being used When walk testing always move across the detection path not toward the detecto
2. of merchantability and fitness for a particular purpose are expressly excluded Because Seller does not install or connect the products and the products may be used in conjunction with products not manufactured by SellerO Seller cannot guarantee the performance of the security system Seller obligation and liability under this warranty is expressly limited to repairing or replacing at Seller s option any product not meeting the specifications In no event shall the Seller be liable to the buyer or any other person for any loss or damages whether direct or indirect or consequential or incidental including without limitation any damages for lost profits stolen goods or claims by any other party caused by defective goods or otherwise arising from the improper incorrect or otherwise faulty installation or use of the merchandise sold TECHNICAL SPECIFICATION FIG 4 Sensor ant la anainn Liah Dual rectangular elem ance tiv Top View Auto Pulse two levels AN ON compensation 10 C to 50 C 14 F Processing Detection Speed Operating Temperature Power Input s amp 12Vdc 31 MA maximu Lens __ I2 generation Fresne Coverage _ 35 11m x 88 5 up to Pet Immunity No alarm for pet unde 15m 11m 5m Om 5m 11m 15m Mounting Height 7 9 ft 2 1m 2 7m seven Alarm Indication Blue LED constant lig Alarm Output N C 28Vde 0 15A m Anti tamper Switch IN C 28Vdc 0 15A M e ri H
3. STK 3302PET PIR Motion Detector INSTALLATION MANUAL SAMTEK SECURITY SYSTEMS The 3302PET with pet immunity is a state of the art analogue detection system that incorporates the following unique features Patented Auto Pulse signal processing with two programmable levels Specially designed lens provides pet immunity up to 18kg 40 Ibs For ANPI listed installati Improved RFI rejection with metal shield The plastic ever enclosure Automatic Temperature Compensation nes High density reflow SMD design Lodif segment Fresnel lens Optional other lenses Fire resistant case FIG 1 EXPLODED VIEW 1 COVER 3 LENS DO NOT TOUCH THE SENSOR SURFACE AS THIS COULD BEZEL PIN 3 RESULT IN DETECTOR MALFUNCTION IF NECESSARY CLEAN USING A SOFT CLOTH AND PURE ALCOHOL 4 BEZEL 6 BEZEL PIN ELECTRICAL CONNECTORS 7 D 10 RF METAL SHIELD COMMENCING INSTALLATION FIG 1 SENN Select the detector s installation site based on the oe aie 11 DETECT ALARM LED BLUE required coverage and recommended height of 2 1m WODE METAL SHIELD PCB 9 J1 LED JUMPER 7ft Avoid proximity to any of the following reflective surfaces direct air flow from vents fans and windows sources of steam oil vapor objects causing temperature changes such as heaters refrigerators ovens and infrared light sources For CUL Listed applications the unit shall be installed in accordance with Part I of the
4. ery high pulse count rate up to 6 or more in the presence of low level signals AUTO TEMPERATURE COMPENSATION These detectors are equipped with automatic temperature compensation ATC which adjusts amplifier gain to maintain coverage levels across a wide range of temperatures WALK TESTING In fast mode J2 ON at 20 C you should not be able to cross more than one complete zone consisting of two beams left and right sensor detecting elements in the coverage area with any kind of movement slow fast walking or running In slow mode J2 OFF the amount of movement required to generate an alarm is doubled The approximate width of a full beam at 11m 35ft from the detector is 1 7m 6ft Please note when the indoor temperature is higher than 25 C the detection distance will be shorter IMPORTANT NOTES The detector cover must be installed properly when conducting walk tests The unit shall be tested annually by the installer in order to comply with UL 639 Only the WA 1 standard lens was tested to UL 639 The unit is intended to be connected to a UL listed control unit or power supply which supplies a minimum of 4 hours of standby power WARRANTY The Seller warrants its products to be free from defects in materials and workmanship under normal use for a period of one year Except as specifically stated herein all express or implied warranties whatsoever statutory or otherwise including without limitation any implied warranty
5. r PET ALLEY To create a pet alley using the pet alley lens the recommended installation height is slightly above the maximum area occupied by the pet The PCB should be set at the 2 1m 7ft mark regardless of the installation height for this lens JUMPER SETTING LED SETTING J1 ON OFF To disable the LED display set jumper J1 to OFF see FIG 1 E i SLOW FAST MODE J2 Jumper J2 is located inside the metal shield and is factory set to the ON position fast mode which is recommended for the majority of installations The use of slow mode jumper OFF is suggested in areas where the incidence of false alarms may be greater To access Jumper J2 use a small screwdriver to gently pry off the metal shield 10 Please refer to FIG 1 TURNING ON THE 3302PET Apply power by connecting the AUX and AUX of the control panel to the and terminals of the detector FIG 3 Powering the detector initiates a self testing program for the signal processor memory and relay The green LED will flash for a period of 35 seconds and the relay will follow the status of the LED AUTO PULSE SIGNAL PROCESSING Patented Auto Pulse Signal Processing provides a variable pulse count rate in response to signal shape strength and width The 3302PET will immediately generate an alarm for very strong signals or switch automatically to pulse counting as signals become weaker The 3302PET motion detector permits a v
6. umidity 95 Maximum Weight 75g 2 60z