SPC-2 Static Pressure Control user manual

image

Contents

1. To program the High alarm Default 0 100 Range from the Low alarm to 0 250 or OFF 1 Press Up or Down until the display shows Hi AL 2 Press Select The current setting in degrees displays and the High alarm LED flashes 3 Press Up or Down to adjust the setting and then press Select The change is saved and the display shows Hi AL 4 Press Down to move to the Low alarm or Back and return to the main display To program the Low alarm Default 0 020 Range 0 000 to High alarm or OFF 1 Press Up or Down until the display shows L aA 2 Press Select The current setting in degrees displays and the Low alarm LED flashes 3 Press Up or Down to adjust the setting and then press Select The change is saved and the display shows LoAL 4 Press Down to move to Open Close or Back to return to the main display Testing and maintaining the SPC 2 Using pressure test mode Pressure test mode allows you to test your equipment and settings by simulating the pressure In pressure test mode you adjust the test pressure 33145000 11 Static Pressure Control Phason As you increase or decrease the test pressure the relays operate according to their settings and the test pressure This gives you an idea of how your system performs over a full range of pressures The relays remain operating according to the test pressure until you exit test mode When the SPC 2 is in pressure test mode it operates the equipment
2. 12 33145000 Phason Static Pressure Control To override the curtain There is a three second delay when switching between Open and Close This is to allow the motor to stop before switching directions The SPC 2 remains in override mode until you exit it does not exit automatically 1 Press Up or Down until the display shows E ur E 2 Press Select The Open and Close LEDs blink rapidly If you are in automatic mode the display shows Aut a If you are in override mode the display shows Dur d 3 Press Up or Down until Gur d override displays 4 Press Select The display shows dL E idle 5 Press Up to switch between idle stop and aPEn open or Down to switch between idle and cta5 close Each time you press the button the curtain starts or stops moving 6 Press Select The control returns to the main menu and the display shows Lurt 7 Press Up or Down to select a different menu item or Back to return the main display To exit manual mode 1 Press Up or Down until the display shows E ur E 2 Press Select The relay LED s blink rapidly and the display shows Gur d Press Up or Down until the display shows Auto 4 Press Select The display shows Cur 5 Press Up or Down to select a different menu item or Back to return the main display Restoring the factory defaults Setting Default Range set point 0 045 0 010 to 0 250 inches of water inWC Open ON duration 20 1 to 900 seconds
3. 0 045 Range 0 to 0 250 inWC Adjust the Idle band Idle band Default 0 060 Range 0 to 0 250 inWC Adjust the curtain open duration Open on duration Default 20 seconds Range 1 to 900 up to 15 minutes Adjust the open idle duration Open off duration Default 15 seconds Range 1 to 900 up to 15 minutes Adjust the close duration Close on duration Default 20 seconds Range 1 to 900 up to 15 minutes Adjust the close idle duration Close off duration Default 15 seconds Range 1 to 900 up to 15 minutes Adjust the high alarm pressure High alarm Default 0 100 Range 0 to 0 250 inWC Adjust the low alarm pressure Low alarm Default 0 020 Range 0 to 0 250 inWC Test Version Installing the Static Pressure Control and sensor i Read and follow all instructions when installing the control and equipment Read Electrical ratings on page 2 Do not exceed the electrical ratings of the control 33145000 3 Static Pressure Control Phason Static Pressure Control layout J J ess amp D Electrical ratings mexe input power AC LINE e 35 to 264 VAC 50 60 Hz 0 12 A Power relays OPEN and CLOSE e 15 A at 120 230 VAC resistive load e 1 2 HP at 120 VAC 1 HP at 230 VAC Alarm relay ALARM 0 4A at 125 VAC 2 0 A at 30 VDC resistive load e 0 2 A at 125 VAC 1 0 A at 30 VDC inductive load Read the installation guide for complete instructions Incoming power terminal connect
4. 1 to 900 up to 15 minutes 1 Press Up or Down until the display shows an 2 Press Select The current setting in seconds displays and the Close on duration LED flashes 3 Press Up or Down to adjust the setting and then press Select The change is saved and the display shows an 4 Press Down to move to the Close off duration or Back to return to the main display 33145000 9 Static Pressure Control Phason To program the Close off duration Default 120 seconds Range 1 to 900 up to 15 minutes Cc 1 Press Up or Down until the display shows LaF F 2 Press Select The current setting in seconds displays and the Close off duration LED flashes 3 Press Up or Down to adjust the setting and then press Select The change is saved and the display shows LaF F 4 Press Down to move to the Idle band or Back to cancel and return to the main display To program the Idle band Default 0 060 Range 0 010 to 0 250 inWC 1 Press Up or Down until the display shows dLE 2 Press Select The current setting in degrees displays and the Idle band LED flashes 3 Press Up or Down to adjust the setting and then press Select The change is saved and the display shows dL 4 Press Down to move to the High alarm or Back to cancel and return to the main display Alarm settings and conditions When there is an alarm condition the alarm relay activates and the Alarm LED flashes The display alternates between t
5. according to the test pressure not according to the measured pressure The SPC 2 does not exit test mode automatically When you are finished testing press Back to exit test mode To use pressure test mode ee 1 Press Up or Down until the display shows EE SE 2 Press Select The display shows Pr E 5 3 Press Select The Test LED flashes and the display shows the test pressure The SPC 2 is now in pressure test mode 4 Press Up or Down to adjust the test pressure The SPC 2 operates the equipment according to the test pressure 5 When finished press Back to return the control to automatic mode Press Back twice to return to the main display Testing the alarm You can manually switch the alarm relay on and off so that you can test your alarm system To test the alarm 1 Press Up or Down until the display shows AL Ar 2 Press Select The display shows aF F off and the Alarm LED flashes Press Up or Down to change the relay state 4 When finished press Back to return to the main menu Press Back again to return to the main display Using manual override mode Manual override mode allows you to override the automatic settings and manually control the curtain You can open close or pause the curtain Manual mode is also useful for testing equipment When the main display is showing and the curtain is in override mode the Open and Close LEDs will blink three times and then stay off for one second
6. s Open OFF duration 15 1 to 900s Close ON duration 20 1 to 900 s Close OFF duration 15 1 to 900 s Idle band 0 060 0 to 0 250 inWC High alarm 0 100 Low alarm to 0 250 inWC Low alarm 0 020 0 000 to High alarm 33145000 13 Static Pressure Control Phason You can restore the default settings using one of two methods the power on method or the power off method The power on method is the easiest way to restore the factory defaults If the power on method does not work use the power off method To restore the factory defaults using the POWER ON method 1 Press Up or Down until the display shows EE SE 2 Press Select The display shows Pr E 5 Press Up or Down until the display shows FACE 4 Press Select The Test LED flashes and the display shows na 5 Press Up or Down to until the display shows YE 5 6 Press Select to restore the factory defaults The control resets displays the version for a few seconds and then displays the pressure To restore the factory defaults using the POWER OFF method lt TIP or We recommend having someone assist you if using the power off method 1 Switch off the power to the control 2 Switch on the power to the control while holding the Up and Down buttons Keep holding the buttons until dE F displays 3 Release the buttons The control resets displays the version for a few seconds and then displays the pressure Displaying the firmware version Firmware
7. the incoming power 85 to 264 VAC 50 60 Hz to this terminal For more information read Connecting the power source on page 5 Open and close relay terminals connect a curtain machine to these terminals For more information read Connecting a curtain machine on page 6 Display connector make sure the ribbon cable from the display is properly connected Alarm relay terminal connect an external alarm system or siren to this terminal For more information read Connecting an alarm system on page 7 Input terminal connect the Static Pressure Sensor SPS 2 to this terminal For more information read Connecting the sensor wiring on page 6 USB connection connect a USB memory stick to this connector to update the firmware For more information read Updating the firmware on page 15 33145000 Phason Static Pressure Control Static Pressure Sensor layout 1 Output terminal connect a cable from here to the control For more information read Connecting the sensor wiring on page 6 2 Low pressure tube remove the red cover and then connect a tube to the room you are controlling For more information read Connecting air tubes on page 6 3 High pressure tube remove the red cover and then connect a tube to an area that is the same pressure as outside Mounting the sensor When mounting the Static Pressure Sensor select a location where you can easily connect it to the control Make sure you Low W W High can run the pressure
8. tubes to the room you are controlling and a9 JE the reference pressure area usually an attic or outside Mounting the control Select a location for the SPC 2 Make sure you have enough wire and tubing to reach the equipment and area you want to control Remove the screws from the front cover and then gently lift it off Mount the enclosure to a wall using the four screws provided with the control Insert the screws into the large holes in each corner of the box and then tighten Connecting the power source aasa Connect the incoming power 85 to 264 VAC 50 60 Hz as im shown in the following diagram Before connecting the incoming power switch OFF the power at the source gt Do not switch ON the power until you have finished all wiring and verified all equipment is properly connected and free of obstructions 33145000 5 Static Pressure Control Phason Connecting the sensor wiring Routing the sensor wires in the same conduit as or beside AC power cables can cause electrical interference or erratic readings Follow these guidelines when routing the sensor wires Use 22 AWG wire no more than 300 feet in length Do not run the wires in the same conduit as AC power cables Do not run the wires beside AC power cables or near electrical equipment When crossing other cables or power lines cross them at a 90 degree angle Connecting air tubes Use PVC or similar fl
9. Phason Static Pressure Control The Static Pressure Control model SPC 2 is a fully programmable controller that provides extensive flexibility for your curtain or awning control needs The SPC 2 automatically controls the pressure in a room by operating a curtain machine according to yout programmed settings Controlling a curtain machine Phas n 7 f Alarm HETA gt Qo Test Cow Version z g rik Set point Close on duration Close off duration idie band D Open on duration j High alarm X i Open off duration i g _ o e M g ny Static Pressure Control X__SPC 2 STi Low alarm Four character LED display Programming and status LEDs Manual override test mode Power failure settings protection Differential pressure sensor Rugged enclosures corrosion resistant water resistant and fire retardant cCSAus approval Limited warranty 2 years for control 90 days for sensor When the pressure is within the Idle band of the Set point the SPC 2 maintains the curtain position When the pressure rises above the Idle band the SPC 2 opens the curtain for the Open On duration and then pauses for the Open Off duration After each Off duration the SPC 2 checks the pressure and then either opens or closes the curtain for the preset duration depending on the pressure Features Automatic pressure based control Two curtain relays one open one close Pr
10. e 2 Click Properties 3 Make sure the file system is FAT32 If the file system is not correct you will need to format the drive as FAT32 or use a different drive that is the correct format pree P 7 oD SS Recent Tabs 4 Recent Fi m Removable Disk General Hardware St Organize Share with New a jE Computer It gt a Removable Disk E M 2 Properties 4 Copy the update file to the root of the USB drive The voor of the drive means wor in a folder Type Removable Disk l 3 File system FAT32 To update the firmware using the POWER ON method 1 Loosen the four cover screws and gently remove the cover from the control Make sure not to disconnect the ribbon cable from the base it must stay properly connected 2 Insert the USB drive into the connector on the back of the cover Press Up or Down until the display shows HEr 4 Press Select The display shows d 5P 5 Press Up or Down until the display shows UP dt Becrical ratings me 6 Press Select The display shows na and the Version LED blinks a 7 Press Up or Down until the display shows YE 5 he 8 Press and 4o d Select until the Test LED blinks rapidly 9 Release the button 33145000 15 Static Pressure Control Phason While the Test LED is blinking rapidly the firmware is updating Updating can take up to 2 minutes After updating the display shows AAAA for a f
11. ew seconds followed by the version number and then the main pressure display 10 When finished remove the USB drive verify the ribbon cable is properly connected and then fasten the cover to the base To update the firmware using the POWER OFF method w lt TIP K We recommend having someone assist you if using the power off method 1 Switch off the power to the control 2 Loosen the four cover screws and gently remove the cover from the control Make sure not to disconnect the ribbon cable from the base it must stay properly connected 3 Insert the USB drive into the connector on the back of the cover 4 Switch on the power to the control while holding the Select button Keep holding the button until the Test LED blinks rapidly 5 Release the button While the Test LED is blinking rapidly the firmware is updating Updating can take up to 2 minutes After updating the display shows 484 for a few seconds followed by the version number and then the main pressure display 6 When finished remove the USB drive verify the ribbon cable is properly connected and then fasten the cover to the base Troubleshooting If you see an error code and are not sure what it means look it up in Alarm settings and conditions on page 10 and then follow the instructions to resolve the condition The following table lists some problems possible causes and possible solutions If you are having a problem usin
12. exible tubing with an mee 5 7 Phas n inside diameter of 3 16 inch ee Static 1 Remove the red caps from the existing air Pressure tubes Sensor 2 Connect a tube to the ambient pressure SPS 2 port LOW and route it to the room you are controlling rey pr Low i i High 3 Connect a tube to the reference pressure port HIGH and route it to an area that is the VE same pressure as the outside lt area you are controlling outside reference area gt Do not blow or force air into the sensor tubes The tubes are connected to highly sensitive equipment Forcing air into a tube can easily damage the sensor Connecting a curtain machine area L N OPEN Curtains are usually controlled by equipment called curtain machines sometimes referred to as wznches Connect the curtain machine to the control as shown in the diagram PPPPSFWPPPFE atv tet 7 6 33145000 Phason Static Pressure Control Connecting an alarm system An alarm system can be a siren an alarm panel or an auto dialer See your alarm siren s installation guide for installation instructions and information about the type of system The descriptions for the alarm terminal are as follows CC common connection CA closed on alarm OA open on alarm To connect an alarm system If you are connecting the alarm system to a network of controls and your system uses a normally open connection closes on alarm connect the system a
13. g the SPC 2 see if the problem is in the following table and then follow the directions for correcting the problem 16 33145000 Phason Static Pressure Control Problem Possible cause Possible solution The power supply components are There has been a power surge Avoid the problem in future by blown or there are burn marks on brownout or power outage providing proper voltage and boards and components protection for the control Motors and fans slow down or stop There is no power display A circuit breaker at service panel is off or lt Reset the circuit breaker tripped The incoming power wiring is incorrect lt Correct the wiring The display shows unusually high or The cable connected to the Static Check the cable connection and low pressure Pressure Sensor is providing a poor tighten it if necessary connection The sensor is not a Phason sensor lt Remove the sensor and then install a Phason sensor The Static Pressure Sensor is damaged Replace the sensor The curtain opens when it should close The wiring is incorrect the close and Correct the wiring For more or closes when it should open open wires are reversed information read Connecting a curtain machine on page 6 The alarm relay is not operating the The alarm wiring is incorrect Correct the wiring For more alarm system information read Connecting an alarm system on page 7 Power contactors Phason s 240 volt power contactors are heavy dut
14. he ambient pressure and the alarm message You cannot acknowledge the alarm until the condition has cleared When the condition goes away the alarm relay deactivates and the Alarm LED switches off The display continues to alternate between the pressure and alarm message until you acknowledge the alarm To acknowledge an alarm press Select There are two alarm conditions High pressure is when the pressure is above the high pressure alarm setting You can adjust the high pressure alarm from the Low alarm value to 0 250 Low pressure is when the pressure is below the low pressure alarm setting You can adjust the low pressure alarm from 0 to the High alarm value 10 33145000 Phason Static Pressure Control Alarm messages Message and description Possible cause Possible solution The ambient pressure is too high lt Increase the open on duration and or D decrease the open off duration to lower the LC y D D pressure in the room The high pressure alarm setting is Increase the high pressure alarm setting For High pressure alarm too low more information read To program the High alarm below The ambient pressure is too low Increase the close on duration and or pee decrease the close off duration to increase D j pressure in the room The low pressure alarm setting is Decrease the low pressure alarm setting For Low pressure alarm too high more information read To program the Low alarm below
15. ing and maintaining the SPC 2 on page 11 5 Fasten the cover to the base Programming the Static Pressure Control Before you begin programming the control make sure it has power and that you have properly connected all equipment to the correct terminals How the curtain settings work Set point the pressure at which the curtain holds its position Idle band the buffer around the set point within which the curtain holds its position Open on duration the duration the curtain opens during the open cycle Open off duration the duration the curtain holds its position during the open cycle Close on duration the duration the curtain closes during the close cycle 6M Close off duration the duration the curtain holds its position during the close cycle Time seconds Open off duration 120 seconds After the curtain opens for the On duration it holds its position 7 for the Off duration Lt jf ff rrr Open on duration 30 seconds EELSETE foe lf the pressure rises above the Idle band the curtain opens for the On duration When the pressure is within the Idle band the curtain remains C t i i iCa Idle band 0 060 0 030 above and below the Set point _ in its current position Pressure inWC D 5 TT eee TTT Close off duration 150 seconds 4 After the curtain closes for the On duration it holds its position for the Off duration to Close on duration 60 seconds lf the press
16. is the internal programming instructions of the SPC 2 It is much like an operating system or software on a computer Just like an operating system the firmware has a version If you call technical support the support agent might ask you for the firmware version To display the firmware version 1 Press Up or Down until the display shows HE r 2 Press Select The display shows d 5P 3 Press Select The display shows the firmware version and the Version LED flashes 4 Press Back twice to return to the main display 14 33145000 Phason Static Pressure Control Updating the firmware At Phason we constantly improve and add new features to our products You can update the firmware in your SPC 2 as these improvements become available all you need is a USB memory stick and a firmware update file You can update the firmware using one of two methods the power on method or the power off method The power on method is the easiest way to update the firmware If for some reason the power on method does not work use the power off method Getting a file You can get a firmware update file from the Phason support forum at www forum phason ca or the Phason website at www phason ca You need to copy the file to a USB memory stick USB drive The USB drive must be formatted as a FAT32 file system To check if the USB drive is the correct format insert it into your computer and then open Windows Explorer 1 Right click the USB driv
17. jury the user should provide adequate back up ventilation supplementary natural ventilation or an independent failure alarm system The user s lack of such precautions acknowledges their willingness to accept the risk of such loss or injury Phason Inc 2 Terracon Place Winnipeg Manitoba Canada Phone 204 233 1400 E mail support phason ca R2J 4G7 Fax 204 233 3252 Web site www phason ca
18. lity and fitness for a particular purpose shall apply to the SPS 2 Any implied warranties are excluded Phason is not liable for consequential damages caused by the SPS 2 Phason does not assume or authorize any representatives or other people to assume any obligations or liabilities other than those specifically stated in this warranty Phason reserves the right to improve or alter the SPS 2 without notice 33145000 19 Service and technical support Phason will be happy to answer all technical questions that will help you use yout SPC 2 Before contacting Phason check the following Read this manual for information about the feature with which you are having trouble If you are having a problem using your SPC 2 look in the Troubleshooting table on page 16 and then follow the directions to correct the problem If you still have a problem with your SPC 2 collect the following information The serial number Any messages displayed by your SPC 2 A description of the problem A description of what you were doing before the problem occurred Phason controls are designed and manufactured to provide reliable performance but they are not guaranteed to be 100 percent free of defects Even reliable products can experience occasional failures and the user should recognize this possibility A If Phason products are used in a life support ventilation system where failure could result in loss or in
19. ogrammable On and Off durations for the open and close relays 1 to 900 seconds R up to 15 minutes Programmable Idle band 0 010 to 0 250 inWC Programmable High and Low pressure alarms Alarm relay for external alarm system Four button keypad Sensor ratings Pressure range 0 to 0 25 inWC Output voltage 0 to 4 VDC Supply voltage 11 to 30 VDC 12 VDC typical 33145000 Supply current 30 mA Operating range 32 to 185 F 0 to 70 C Storage range 40 to 194 F 40 to 90 C Overpressute 20 psi Phason Electrical ratings Input power 85 to 264 VAC 50 60 Hz Open close relays 15 A at 120 230 VAC resistive load 1 2HP at 120 VAC 1 HP at 230 VAC Alarm relay 0 4 A at 125 VAC 2 A at 30 VDC resistive load 0 2 A at 125 VAC 1 A at 30 VDC inductive load must install power contactors For more information read Power contactors on page 17 If you are connecting any equipment that exceeds the ratings of the relays you Becoming familiar with the SPC 2 The main display shows the pressure and any alarm messages The main display is what you see when you are not in a menu or settings display Here are some things to know about the main display Alarm shows when there is an alarm Alarm condition Status LEDs show the status of the relays or which relay is being Open Test Test shows when test mode is active Close Version controlled Version show
20. s shown in the normally open diagram Join all the common CC connections together and all the closed on alarm CA connections together The SPC 2 alarm relays must be in parallel with each other so any control can trigger the alarm system when an alarm condition occurs If you are connecting the alarm system to a network of controls and your system uses a normally closed connection opens on alarm connect the system as shown in the normally closed diagram Join the alarm relays in a continuous loop The SPC 2 alarm relays must be in series with each other so any control can trigger the alarm system when an alarm condition occurs Normally open system closed on alarm Normally closed system open on alarm ee Finishing the installation After you have finished connecting all equipment 1 Oh oa Make sure all wires are properly connected to the correct terminals Place the cover on the control Switch on the power to the control it should display AAAA for three seconds the version for example u 100 for three seconds and then the pressure 33145000 7 Static Pressure Control Phason If the display does not light up go back to step 1 If the alarm settings are not properly set or the sensor is not properly connected the display will likely show an alarm message For more information read Alarm settings and conditions on page 10 4 Test the equipment For more information read Test
21. s the firmware version Programming LEDs show which Set point Close on duration setting is being displayed or e uebamd Close orf duration Programming LEDs rogrammed Open on duration High alarm p l Open off duration Low alarm Press Down to scroll down or Lv lt Press Select to select an option or decrease a value accept a value Press Up to scroll up or increase df Press Back to go back or cancel a value changes When a relay is on the status LED for that relay is lit When there is an alarm condition the display flashes between the alarm message and the current pressure For more information about alarms read Alarm settings and conditions on page 10 When the control is in manual override mode the Open and Close LEDs will blink three times and then stay off for one second For more information read Using manual override mode on page 12 2 33145000 Phason Static Pressure Control Main menu When you are in the main menu the display shows the menu items the LEDs light up to show you which menu item is selected Press Up or Down to move through the menu items Menu item Function Open Close select automatic or manual override open close or idle Alarm Switch the alarm relay on or off for testing only Adjust the test pressure Restore the factory defaults Display the firmware version Update the firmware version Adjust the curtain set point set point Default
22. sure Sensor limited warranty This warranty applies only to the Static Pressure Sensor SPS 2 If you need warranty service return the product and original proof of purchase to your dealer Phason Inc Phason warrants the SPS 2 subject to the following terms and conditions This warranty is valid only to the original purchaser of the product for 90 days from the manufacturing date The manufacturing date is stated in the first eight digits of the serial number in the form year month day Phason hereby warrants that should the SPS 2 fail because of improper workmanship Phason will repair the unit effecting all necessary parts replacements without charge for either parts or labor Conditions Installation must be done according to our enclosed installation instructions The product must not have been previously altered modified or repaired by anyone other than Phason The product must not have been involved in an accident misused abused or operated or installed contrary to the instructions in our user and or installation manuals Phason s opinion about these items is final The person requesting warranty service must be the original purchaser of the unit and provide proof of purchase upon request All transportation charges for products submitted for warranty must be paid by the purchaser Except to the extent prohibited by applicable law no other warranties whether expressed or implied including warranties of merchantabi
23. ure falls below the Idle band the curtain closes for the On duration 8 33145000 Phason Static Pressure Control To program the Set point Default 0 045 Range 0 to 0 250 inWC 1 Press Down until the display shows 5EP i 2 Press Select The current setting in degrees displays and the Set point LED flashes 3 Press Up or Down to adjust the setting and then press Select The change is saved and the display shows SEPE 4 Press Down to move to the Open on duration or Back return to the main display To program the Open on duration Default 15 seconds Range 1 to 900 up to 15 minutes 1 Press Up or Down until the display shows an 2 Press Select The current setting in seconds displays and the Open on duration LED flashes 3 Press Up or Down to adjust the setting and then press Select The change is saved and the display shows an 4 Press Down to move to the Open off duration or Back return to the main display To program the Open off duration Default 180 seconds Range 1 to 900 up to 15 minutes 1 Press Up or Down until the display shows Daf F 2 Press Select The current setting in seconds displays and the Open off duration LED flashes 3 Press Up or Down to adjust the setting and then press Select The change is saved and the display shows UaF 4 Press Down to move to the Close on duration or Back to return to the main display To program the Close on duration Default 30 seconds Range
24. y relays that increase the load handling capability of control relays Power contactor relay PC 240 includes power contactor relay and mounting hardware for easy mounting in an enclosure Power contactor kit 122 1 includes power contactor relay on off auto switch and label snubber filter reduces electrical noise and mounting hardware for easy mounting in an enclosure Power contactor unit 129 0 includes two power contactor relays two on off auto switches and two snubber filters mounted in a large enclosure The enclosure has room for two additional contactor relays or kits Parts and kits If the display fails you can replace it with a display kit After replacing the display you will need to program the control If the bottom circuit board fails you can replace it with a control kit Pressure sensor SPS 2 Display kit model KSPC2 DISPLAY Control kit model KSPC2 CONTROL 33145000 17 Static Pressure Control Phason Static Pressure Control limited warranty This warranty applies only to the Static Pressure Control SPC 2 If you need warranty service return the product and original proof of purchase to your dealer Phason Inc Phason warrants the SPC 2 subject to the following terms and conditions This warranty is valid only to the original purchaser of the product for two years from the manufacturing date The manufacturing date is stated in the first eight digits of the serial number in the form
25. year month day Phason hereby warrants that should the SPC 2 fail because of improper workmanship Phason will repair the unit effecting all necessary parts replacements without charge for either parts or labor Conditions Installation must be done according to our enclosed installation instructions The product must not have been previously altered modified or repaired by anyone other than Phason The product must not have been involved in an accident misused abused or operated or installed contrary to the instructions in our user and or installation manuals Phason s opinion about these items is final The person requesting warranty service must be the original purchaser of the unit and provide proof of purchase upon request All transportation charges for products submitted for warranty must be paid by the purchaser Except to the extent prohibited by applicable law no other warranties whether expressed or implied including warranties of merchantability and fitness for a particular purpose shall apply to the SPC 2 Any implied warranties are excluded Phason is not liable for consequential damages caused by the SPC 2 Phason does not assume or authorize any representatives or other people to assume any obligations or liabilities other than those specifically stated in this warranty Phason reserves the right to improve or alter the SPC 2 without notice 18 33145000 Phason Static Pressure Control Static Pres