Home

User guide

image

Contents

1. Home Ramp Time Humidity Level Mask Run Mask Fit Airplane Mode Sleep Report Ramp Time Designed to make the beginning of therapy more comfortable Ramp Time is the period during which the pressure increases from a low start pressure to the prescribed treatment pressure You can set your Ramp Time to Off 5 to 45 minutes or Auto When Ramp Time is set to Auto the device will detect when you have fallen asleep and then automatically rise to the prescribed treatment pressure My Options My Options JS To adjust Ramp Time 1 In My Options turn the dial to highlight Ramp Time and then press the dial lt Home Ramp Time 2 Turn the dial to adjust the ramp time to your preferred setting and press the dial to save the change Humidity Level ty Auto Mask Run Mask Fit gt Airplane Mode Off Humidity Level The humidifier moistens the air and is designed to make therapy more comfortable If you are getting a dry nose or mouth turn up the humidity If you are getting any moisture in your mask turn down the humidity You can set the Humidity Level to Off or between 1 and 8 where 1 is the lowest humidity setting and 8 is the highest humidity setting 6 My Options My Options JUS To adjust the Humidity Level lt H mer me Ms rma ava 1 In My Options turn the dial to highlight Humidity Ramp Time Level and then press the dial Humidity Level 4 l 2 Turn the dial to adjust the humidity level an
2. ResMed AirSense 10 AuToset AUTOSET FOR HER User guide English ENGLISH Welcome The AirSense 10 AutoSet and AirSense 10 AutoSet for Her are ResMed s premium auto adjusting pressure devices The AirSense 10 Elite and Airsense 10 CPAP are ResMed s Continuous Positive Airway Pressure CPAP devices Z WARNING Read this entire guide before using the device Z CAUTION In the US Federal law restricts this device to sale by or on the order of a physician Indications for use AirSense 10 AutoSet The AirSense 10 AutoSet self adjusting device is indicated for the treatment of obstructive sleep apnea OSA in patients weighing more than 66 Ib 30 kg It is intended for home and hospital use The humidifier is intended for single patient use in the home environment and re use in a hospital institutional environment AirSense 10 AutoSet for Her The AirSense 10 AutoSet for Her self adjusting device is indicated for the treatment of obstructive sleep apnea OSA in patients female patients with mild to moderate OSA when using AutoSet for Her treatment mode weighing more than 66 Ib 30 kg It is intended for home and hospital use The humidifier is intended for single patient use in the home environment and re use in a hospital institutional environment AirSense 10 Elite The AirSense 10 Elite device is indicated for the treatment of obstructive sleep apnea OSA in patients weighing more than 66 I
3. Operating temperature Operating humidity Operating altitude Storage and transport temperature Storage and transport humidity 100 240V 50 60Hz 1 0 1 5A Class Il 115V 400Hz 1 5A Class II nominal for aircraft use 24V 3 75A 53W 57VA 104W 108VA 41 F to 95 F 5 C to 35 C Note The air flow for breathing produced by this therapy device can be higher than the temperature of the room Under extreme ambient temperature conditions 104 F 40 C the device remains safe 10 to 95 relative humidity non condensing Sea level to 8 500 2 591 m air pressure range 1013 hPa to 738 hPa 4 F to 140 F 20 C to 60 C 5 to 95 relative humidity non condensing English 15 Electromagnetic compatibility The AirSense 10 complies with all applicable electromagnetic compatibility requirements EMC according to IEC60601 1 2 2007 for residential commercial and light industry environments It is recommended that mobile communication devices are kept at least 1 m away from the device Information regarding the electromagnetic emissions and immunity of this ResMed device can be found on www resmed com on the Products page under Service and Support IEC 60601 1 2005 classification Class II double insulation Type BF Ingress protection IP22 Sensors Pressure sensor Internally located at device outlet analog gauge pressure type 5 to 45 cm H20 Flow sensor Internally located at device inlet
4. unblocked to maintain the flow of the fresh air into the mask e Becareful not to place the device where it can be bumped or where someone is likely to trip over the power cord e Blocking the air tubing and or air inlet of the device while in operation could lead to overheating of the device e Keep the area around the device dry clean and clear of anything eg clothes or bedding that could block the air inlet or cover the power supply unit e Do not place the device on its side as water might get into the device e Incorrect system setup may result in incorrect mask pressure reading Ensure the system is correctly set up e Do not use bleach chlorine alcohol or aromatic based solutions moisturizing or antibacterial soaps or scented oils to clean the device the water tub or air tubing These solutions may cause damage or affect the humidifier performance and reduce the life of the products e If you use the humidifier always place the device on a level surface lower than your head to prevent the mask and air tubing from filling with water e Leave the water tub to cool for ten minutes before handling to allow the water to cool and to make sure that the water tub is not too hot to touch e Make sure that the water tub is empty before transporting the device Technical specifications 90W power supply unit AC input range DC output Typical power consumption Peak power consumption Environmental conditions
5. Check the air filter and replace it at least every six months Replace it more often if there are any holes or blockages by dirt or dust To replace the air filter 1 Open the air filter cover and remove the old air filter The air filter is not washable or reusable 2 Place a new air filter onto the air filter cover and then close it Make sure the air filter is fitted at all times to prevent water and dust from entering the device Reassembling When the water tub and air tubing are dry you can reassemble the parts 1 Connect the air tubing firmly to the air outlet located on the rear of the device 2 Open the water tub and fill it with distilled room temperature water up to the maximum water level mark 3 Close the water tub and insert it into the side of the device 4 Connect the free end of the air tubing firmly onto the assembled mask Therapy data Your AirSense 10 device records your therapy data for you and your care provider so they can view and make changes to your therapy if required The data is recorded and then transferred to your care provider wirelessly or via an SD card Wireless Your AirSense 10 device is equipped with cellular communication This allows your therapy data to be wirelessly transmitted to your care provider to enhance the quality of your treatment The Wireless signal strength icon alll displayed at the top right of your screen indicates the signal strength The data is usually transmitted
6. after therapy has stopped In order to make sure that your data is transferred leave your device connected to the mains power at all times and make sure that it is not in Airplane Mode Notes e Therapy data might not be transmitted if you use it outside of the country or region of purchase e Devices with cellular communication might not be available in all regions SD card An alternative way for your therapy data to be transferred to your care provider is via the SD card Your care provider may ask you to send the SD card by mail or to bring it in When instructed by your care provider remove the SD card Do not remove the SD card from the device when the SD light is flashing English 9 To remove the SD card 1 Open the SD card cover 2 Push in the SD card to release it Remove the SD card from the device Place the SD card in the protective folder and send it back to your care provider For more information on the SD card refer to the SD card protective folder provided with your device Note The SD card should not be used for any other purpose Traveling You can take your AirSense 10 device with you wherever you go Just keep the following in mind e Use the travel bag provided to prevent damage to the device e Empty the water tub and pack it separately in the travel bag e Make sure you have the appropriate power cord for the region you are traveling to For information on purchasing contact your care provid
7. amination due to cigarette pipe cigar or other smoke Warranty is void on product sold or resold outside the region of original purchase Warranty claims on defective product must be made by the initial consumer at the point of purchase This warranty replaces all other expressed or implied warranties including any implied warranty of merchantability or fitness for a particular purpose Some regions or states do not allow limitations on how long an implied warranty lasts so the above limitation may not apply to you ResMed shall not be responsible for any incidental or consequential damages claimed to have resulted from the sale installation or use of any ResMed product Some regions or states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from region to region For further information on your warranty rights contact your local ResMed dealer or ResMed office Further information If you have any questions or require additional information on how to use the device contact your care provider 20 ResMed ResMed Ltd DISTRIBUTED BY 1 Elizabeth Macarthur Drive ResMed Corp 9001 Spectrum Center Boulevard San Diego CA 92123 USA wauawe Bella Vista NSW 2153 Australia ResMed UK Ltd 96 Jubilee Ave Milton Park Abingdon Oxfordshire 0X14 4RW UK See www resmed com for ot
8. ation at 10 cm H20 according to ISO 17510 1 2007 Standard air tubing SlimLine air tubing Without humidification 0 5 cm H20 0 5 cm H20 With humidification 0 5 cm H20 0 5 cm H20 Maximum dynamic pressure variation according to ISO 17510 1 2007 Device without humidification and Standard air tubing Device with humidification and Standard air tubing Pressure cm H20 10 BPM 15 BPM 20 BPM 4 0 5 0 5 0 5 0 5 0 8 0 8 8 0 5 0 5 0 5 0 5 0 8 0 8 12 0 5 0 5 0 5 0 5 0 8 0 8 16 0 5 0 5 0 5 0 5 0 8 0 8 20 0 5 0 5 0 5 0 5 0 8 0 8 Device without humidification and SlimLine air tubing Device with humidification and SlimLine air tubing Pressure cm H20 10 BPM 15 BPM 20 BPM 4 0 5 0 5 0 5 0 5 0 8 0 8 8 0 5 0 5 0 5 0 5 0 8 0 8 12 0 5 0 5 0 5 0 5 0 8 0 8 16 057 05 0 5 0 5 0 8 0 8 20 0 5 0 5 0 5 0 5 0 8 0 8 18 Symbols The following symbols may appear on the product or packaging Read instructions before use A Indicates a warning or caution Follow instructions before use wal Manufacturer EC REP European Authorized Representative LOT Batch code REF Catalog number Serial number Device number On Off A Device weight IP22 Protected against finger sized objects and against dripping water when tilted up to 15 degrees from specified orientation gt gt gt Direct current A type BF applied part o Class I equipment SS Humidity limitation 4 Temperature limitation Non ionising radiation amp China polluti
9. b 30 kg It is intended for home and hospital use The humidifier is intended for single patient use in the home environment and re use in a hospital institutional environment AirSense 10 CPAP The AirSense 10 CPAP device is indicated for the treatment of obstructive sleep apnea OSA in patients weighing more than 66 Ib 30 kg It is intended for home and hospital use The humidifier is intended for single patient use in the home environment and re use in a hospital institutional environment Contraindications Positive airway pressure therapy may be contraindicated in some patients with the following pre existing conditions e severe bullous lung disease e pneumothorax e pathologically low blood pressure e dehydration e cerebrospinal fluid leak recent cranial surgery or trauma English 1 Adverse effects You should report unusual chest pain severe headache or increased breathlessness to your prescribing physician An acute upper respiratory tract infection may require temporary discontinuation of treatment The following side effects may arise during the course of therapy with the device e drying of the nose mouth or throat e nosebleed e bloating e ear or sinus discomfort e eye irritation e skin rashes At a glance The AirSense 10 includes the following e Device with HumidAir integrated humidifier e Water tub e Air tubing e Power supply unit e Travel bag e SD card already inserted Con
10. d press the dial to save the change Mask Run Mask Fit Airplane Mode If you continue to get a dry nose or mouth or moisture in your mask consider using ClimateLineAir heated air tubing ClimateLineAir together with Climate Control delivers more comfortable therapy Mask Fit Mask Fit is designed to help you assess and identify possible air leaks around your mask My Options ulk To Check Mask Fit 1 Fit the mask as described in the mask user guide 2 In My Options turn the dial to highlight Run Mask Fit and then press the dial The device starts blowing air K Mask Fit 3 Adjust the mask mask cushion and headgear until you get a Good result To stop Mask Fit press the dial or Start Stop If you are unable to get a good mask seal talk to your care provider More options Your care provider may have given you access to personalize a few more options Pressure Relief When Pressure Relief is enabled you may find it easier to breathe out This can help you get used to therapy SmartStart When SmartStart is enabled therapy starts automatically when you breathe into your mask When you remove your mask it stops automatically after few seconds Mask This option shows your mask type setting If you use more than one type of mask adjust this setting when switching between masks Run Warmup This option allows you to pre heat the water before starting therapy so that the air is not cold or dry at the begi
11. digital mass flow type 70 to 180 L min Maximum single fault steady pressure Device will shut down in the presence of a single fault if the steady state pressure exceeds 30 cm H20 for more than 6 sec or 40 cm H20 for more than 1 sec Sound Pressure level measured according to ISO 17510 1 2007 CPAP mode SlimLine 26 6 dBA with uncertainty of 2 dBA Standard 26 6 dBA with uncertainty of 2 dBA Power level measured according to ISO 17510 1 2007 CPAP mode SlimLine 34 6 dBA with uncertainty of 2 dBA Standard 34 6 dBA with uncertainty of 2 dBA Declared dual number noise emission values in accordance with ISO 4871 1996 Physical device and water tub Dimensions H x W x D 4 57 x 10 04 x 5 91 116 mm x 255 mm x 150 mm Air outlet complies with ISO 5356 1 2004 22 mm Weight device and standard water tub 44 07 1248 g Weight device and cleanable water tub 44 o0z 1248 g Housing construction Flame retardant engineering thermoplastic Water capacity To maximum fill line 380 mL Standard water tub material Injection molded plastic stainless steel and silicone seal Cleanable water tub material Injection molded plastic stainless steel and silicone seal Temperature Maximum heater plate 154 F 68 C Cut out 165 F 74 C Maximum gas temperature lt 106 F lt 41 C Air filter Standard Material Polyester non woven fiber Average arrestance gt 75 for 7 micron dust Hypoallergenic Material Acrylic and
12. er e f you are using an external battery you should turn off the humidifier in order to maximize the life of your battery Do this by turning the Humidity Level to Off Traveling by plane Your AirSense 10 device may be taken on board as carry on luggage Medical devices do not count toward your carry on luggage limit You can use your AirSense 10 device on a plane as it meets the Federal Aviation Administration FAA requirements Air travel compliance letters can be downloaded and printed from www resmed com When using the device on a plane e Make sure the water tub is completely empty and inserted into your device The device will not work without the water tub inserted e Turn on Airplane Mode My Options 4 My Options Ja To turn on Airplane Mode lt H ome AREF 1 In My Options turn the dial to highlight Airplane Ramp Time Mode and then press the dial Cancel Humidity Level i 2 Turn the dial to select On and then press the dial to save the change The Airplane Mode icon gt is displayed at the top right of the screen Mask Run Mask Fit Z CAUTION Do not use the device with water in the water tub on a plane due to the risk of inhalation of water during turbulence Troubleshooting If you have any problems have a look at the following troubleshooting topics If you are not able to fix the problem contact your care provider or ResMed Do not try to open the device General troublesho
13. er cord into the power supply unit and the other end into the power outlet 3 Connect the air tubing firmly to the air outlet located on the rear of the device 4 Open the water tub and fill it with distilled water up to the maximum water level mark Do not fill the water tub with hot water 5 Close the water tub and insert it into the side of the device 6 Connect the free end of the air tubing firmly onto the assembled mask See the mask user guide for detailed information Recommended masks are available on www resmed com Starting therapy 1 Fit your mask 2 Press Start Stop or breathe normally if SmartStart is enabled You will know that therapy is on when the Sleep Report screen is displayed The current treatment pressure is shown in green Sleep Report During ramp time the pressure is gradually increasing and you will see a spinning circle Once the prescribed treatment pressure is reached the entire Pressure 12 0 20 0 i l circle will be green 4 0 The screen will go black automatically after a short period of time You can press Home or the dial to turn it back on If power is interrupted during therapy the device will automatically restart therapy when power is restored The AirSense 10 device has a light sensor that adjusts the screen brightness based on the light in the room Stopping therapy 1 Remove your mask 2 Press Start Stop or if SmartStart is enabled therapy will st
14. her ResMed locations worldwide For patent information see www resmed com ip Air10 AirSense AutoSet ClimateLine HumidAir and SlimLine are trademarks of ResMed Ltd AutoSet SlimLine and ClimateLine are registered in U S Patent and Trademark Office SD Logo is a trademark of SD 3C LLC 2014 ResMed Ltd 378120 2 2014 07 ResMed com NENET AN N aL 378120
15. nning of therapy Caring for your device It is important that you regularly clean your AirSense 10 device to make sure you receive optimal therapy The following sections will help you with disassembling cleaning checking and reassembling your device English 7 Disassembling ES OL S Hold the water tub at the top and bottom press it gently and pull it away from the device Open the water tub and discard any remaining water Hold the cuff of the air tubing and gently pull it away from the device Hold both the cuff of the air tubing and the swivel of the mask then gently pull apart Cleaning You should clean the device weekly as described Refer to the mask user guide for detailed Instructions on cleaning your mask 1 Wash the water tub and air tubing in warm water using mild detergent Do not wash in a dishwasher or washing machine Rinse the water tub and air tubing thoroughly and allow to dry out of direct sunlight and or heat Wipe the exterior of the device with a dry cloth Checking You should regularly check the water tub air tubing and the air filter for any damage ls FR d Check the water tub e Replace it if it is leaking or has become cracked cloudy or pitted e Replace it if the seal is cracked or torn e Remove any white powder deposits using a solution of one part household vinegar to 10 parts water Check the air tubing and replace it if there are any holes tears or cracks
16. on control logo 1 D G China pollution control lo78030go 2 Rx Only Prescription only In the US Federal law restricts these devices to sale by or on the order of a physician _AAMAX Maximum water level mF Use distilled water only g Operating altitude 20 Atmospheric pressure limitation Qs Complies with RTCA DO 160 section 21 category M m Environmental information This device should be disposed of separately not as unsorted municipal waste To dispose of your device you should use appropriate collection reuse and recycling systems available in your region The use of these collection reuse and recycling systems is designed to reduce pressure on natural resources and prevent hazardous substances from damaging the environment If you need information on these disposal systems please contact your local waste administration The crossed bin symbol invites you to use these disposal systems If you require information on collection and disposal of your ResMed device please contact your ResMed office local distributor or go to www resmed com environment Servicing The AirSense 10 device is intended to provide safe and reliable operation when operated in accordance with the instructions provided by ResMed ResMed recommends that the AirSense 10 device be inspected and serviced by an authorized ResMed Service Centre if there is any sign of wear or concern with device function Otherwise service and inspection of the products generall
17. op automatically after a few seconds The Sleep Report now gives you a summary of your therapy session Usage hours Indicates the number of hours of therapy you received last session Sleep Report Uae k Home pre Mask Seal Indicates how well your mask sealed 7 15 hours Good mask seal Mask un Q Needs adjusting see Mask Fit Humidifier 3 Humidifier Indicates if your humidifier is working properly Humidifier working Humidifier might be faulty contact your care provider If set by your care provider you will also see Events AHI per hour Indicates the number of apneas and hypopneas experienced per hour More Info Turn the dial to scroll down to view more detailed usage data English 5 Power save mode Your AirSense 10 device records your therapy data In order to allow it to transmit the data to your care provider you should not unplug the device However you can put it into power save mode to save electricity To enter power save mode e Press and hold Start Stop for three seconds The screen goes black To exit power save mode e Press Start Stop once The Home screen is displayed My Options Your AirSense 10 device has been set up for your needs by your care provider but you may find you want to make small adjustments to make your therapy more comfortable Highlight My Options and press the dial to see your current settings From here you can personalize your options
18. opped therapy but the device is still blowing air Device is cooling down Device blows a small amount of air in order to avoid condensation in the air tubing It will stop automatically after 20 minutes My water tub is leaking Water tub may not be assembled correctly Check for damage and reassemble the water tub correctly Water tub may be damaged or cracked Contact your care provider for a replacement My therapy data has not been sent to my care provider Wireless coverage may be poor Make sure that the device is placed where there is coverage ie on your bedside table not in a drawer or on the floor The Wireless signal strength icon ulll indicates good coverage when all bars are displayed and poor coverage when fewer bars are displayed The No wireless connection icon M l is displayed on the Make sure that the device is placed where there is coverage top right of the screen No wireless network available ie on your bedside table not in a drawer or on the floor If instructed to do so send the SD card to your care provider The SD card also contains your therapy data Device may be in Airplane Mode Turn off Airplane Mode see Traveling by plane Data transfer is not enabled for your device Contact your care provider to enable the data transfer Service My screen and buttons are flashing Software upgrade is in progress Software upgrade takes approximately 10 minutes to complete Device messages Device message p
19. ossible cause Solution High leak detected check your water tub tub seal or side cover Water tub may not be inserted properly Make sure the water tub is correctly inserted Water tub seal may not be inserted properly Open the water tub and make sure that the seal is correctly inserted High leak detected connect your tubing Air tubing may not be connected properly Make sure the air tubing is firmly connected at both ends Mask may be fitted incorrectly Make sure your mask is fitted correctly See your mask user guide for fitting instructions or use the Mask Fit function to check your mask fit and seal Tubing blocked check your tubing Air tubing may be blocked Check the air tubing and remove any blockages Press the dial to clear the message and then press Start Stop to restart the device SD card error remove your card and press Start to begin therapy SD card may not be inserted correctly Remove and reinsert the SD card Read only card please remove unlock and re insert SD card SD card switch may be in the lock read only position Move the switch on the SD Card from the lock position fa to the unlock position m and then re insert it System fault refer to user guide Error 004 Device may have been left in a hot environment Allow to cool before re use Disconnect the power supply and then reconnect it to restart the device Air filter may be blocked Check the air filter and replace it if there are any blockage
20. oting Problem possible cause Solution Air is leaking from around my mask Mask may be fitted incorrectly Make sure your mask is fitted correctly See your mask user guide for fitting instructions or use the Mask Fit function to check your mask fit and seal am getting a dry or blocked nose Humidity level may be set too low Adjust the Humidity Level If you have ClimateLineAir heated air tubing see the ClimateLineAir user guide am getting droplets of water on my nose in the mask and air tubing Humidity level may be set too high Adjust the Humidity Level If you have ClimateLineAir heated air tubing see the ClimateLineAir user guide My mouth is very dry and uncomfortable Air may be escaping through your mouth Increase the Humidity Level You may need a chin strap to keep your mouth closed or a full face mask Air pressure in my mask seems too high it feels like am getting too much air Ramp may be turned off Use the Ramp Time option Air pressure in my mask seems too low it feels like am not getting enough air Ramp may be in progress Wait for air pressure to build up or turn Ramp Time off My screen is black Backlight on the screen may have turned off It turns off Press Home or the dial to turn it back on automatically after a short period of time Power may not be connected Connect the power supply and make sure the plug is fully inserted English 11 Problem possible cause Solution have st
21. polypropylene fibers in a polypropylene carrier Efficiency gt 98 for 7 8 micron dust gt 80 for 0 5 micron dust Aircraft use ResMed confirms that device meets the Federal Aviation Administration FAA requirements RTCA DO 160 section 21 category M for all phases of air travel Wireless module Technology used FCC ID 2ACHL AIR10CD The AirSense 10 device complies with FCC Rules CDMA USA and Canada only 2G GSM all regions except USA and Canada The AirSense 10 device should be used at a minimum distance of 0 8 2 cm from the body during operation Additional information regarding the FCC Rules for this device can be found on www resmed com Operating pressure range AutoSet AutoSet For Her Elite CPAP Supplemental oxygen Maximum flow Pneumatic flow path 1 2 3 Design life Device power supply unit Cleanable water tub Standard water tub air tubing General The patient is an intended operator Humidifier performance 4 to 20 cm H20 4 L min 1 Flow sensor 2 Blower 3 Pressure sensor 4 Mask 5 Air tubing 6 Water tub 7 Device 8 Inlet filter D years 2 5 years 6 months The following settings have been tested at 71 6 F 22 C ambient temperature Mask Pressure RH output cm H20 Setting 4 Setting 8 4 85 100 10 85 100 20 85 90 1 AH Absolute Humidity in mg L 2 BTPS Body Temperature Pressure Saturated Nominal system output AH BTPS Setting 4 Se
22. s Disconnect the power supply and then reconnect it to restart the device Air tubing may be blocked Check the air tubing and remove any blockages Press the dial to clear the message and then press Start Stop to restart the device There may be water in the air tubing Empty the water from the air tubing Disconnect the power supply and then reconnect it to restart the device All other error messages for example System fault refer to user guide Error OXX An unrecoverable error has occurred on the device Contact your care provider Do not open the device English 13 Reassembling parts Some parts of your device are designed to easily come off in order to avoid damage to the parts or the device You can easily reassemble them as described below To insert the water tub seal 1 Place the seal into the lid 2 Press down along all edges of the seal until it is firmly in place To reassemble the water tub lid 1 Insert one side of the lid into the pivot hole of the base 2 Slide the other side down the ridge until it clicks into place General warnings and cautions WARNING e Make sure that you arrange the air tubing so that it will not twist around the head or neck e Make sure the power cord and plug are in good condition and the equipment is not damaged e Keep the power cord away from hot surfaces e lf you notice any unexplained changes in the performance of the device if it is making unusual
23. sounds if the device or the power supply are dropped or mishandled or if the enclosure is broken discontinue use and contact your care provider or your ResMed Service Center e Do not open or modify the device There are no user serviceable parts inside Repairs and servicing should only be performed by an authorized ResMed service agent e Beware of electrocution Do not immerse the device power supply or power cord in water If liquids are spilled into or onto the device unplug the device and let the parts dry Always unplug the device before cleaning and make sure that all parts are dry before plugging it back in e Supplemental oxygen must not be used while smoking or in the presence of an open flame e Always make sure that the device is turned on and airflow generated before the oxygen supply is turned on Always turn the oxygen supply off before the device is turned off so that unused oxygen does not accumulate within the device enclosure and create a risk of fire e Do not perform any maintenance tasks while the device is in operation Z CAUTION e Use only ResMed parts and accessories with the device Non ResMed parts may reduce the effectiveness of the treatment and or damage the device e Use only vented masks recommended by ResMed or by the prescribing doctor with this device Fitting the mask without the device blowing air can result in rebreathing of exhaled air Make sure that the mask vent holes are kept clear and
24. tact your care provider for a range of accessories available for use with the device including e Air tubing heated and non heated ClimateLineAir SlimLine Standard e Water tub Standard water tub cleanable water tub can be disinfected e Filter Hypoallergenic filter standard filter e Air10 DC DC converter e SD card reader e Air10 oximeter adapter e Air10 USB adapter About your device A U N gt Air outlet Air filter cover Power inlet Serial number and device number About the control panel Co Start Stop button O Dial Home button Water tub Screen Adapter cover CON O 01 SD card cover Press to start stop therapy Press and hold for three seconds to enter power save mode Turn to navigate the menu and press to select an option Turn to adjust a selected option and press to save your change Press to return to the Home screen Different icons may be displayed on the screen at different times including A Ramp Time Ramp Time Auto amp S55 APA A Humidity Humidifier warming Humidifier cooling Wireless signal strength green Wireless transfer not enabled gray A No wireless connection gt Airplane Mode English 3 Z CAUTION Do not overfill the water tub as water may enter the device and air tubing 1 Place the device on a stable level surface 2 Plug the power connector into the rear of the device Connect one end of the pow
25. tting 8 6 gt 10 6 gt 10 6 gt 10 English 17 Air tubing Air tubing Material Length Inner diameter ClimateLineAir Flexible plastic and electrical components 6 6 2 m 0 6 15 mm SlimLine Flexible plastic 6 1 8 m 0 6 15 mm Standard Flexible plastic 6 6 2 m 0 75 19 mm Heated air tubing temperature cut out lt 106 F lt 41 C Notes e The manufacturer reserves the right to change these specifications without notice e The electrical connector end of the heated air tubing is only compatible with the air outlet at the device end and should not be fitted to the mask e Do not use electrically conductive or antistatic air tubing e The temperature and relative humidity settings displayed are not measured values Displayed values Value Range Display resolution Pressure sensor at air outlet Mask pressure 4 20 cm H20 0 1 cm H20 Flow derived values Leak 0 120 L min 1 L min Value Accuracy Pressure measurement Mask pressure 0 5 cm H20 4 of measured value Flow and flow derived values Flow 6 L min or 10 of reading whichever is greater at 0 to 150 L min positive flow Leak 12 L min or 20 of reading whichever is greater 0 to 60 L min 1 Results are expressed at ATPD Ambient Temperature and Pressure Dry 2 Accuracy may be reduced by the presence of leaks supplemental oxygen tidal volumes lt 100 mL or minute ventilation lt 3 L min Pressure accuracy Maximum static pressure vari
26. y should not be required during their design life Limited warranty ResMed Ltd hereafter ResMed warrants that your ResMed product shall be free from defects in material and workmanship from the date of purchase for the period specified below Product Warranty period e Mask systems including mask frame cushion headgear and tubing excluding 90 days single use devices e Accessories excluding single use devices e Flex type finger pulse sensors e Humidifier water tubs e Batteries for use in ResMed internal and external battery systems 6 months English 19 e Clip type finger pulse sensors 1 year e CPAP and bilevel device data modules e Oximeters and CPAP and bilevel device oximeter adapters e Humidifier cleanable water tubs e Titration control devices e CPAP bilevel and ventilation devices including external power supply units 2 years e Humidifiers e Battery accessories e Portable diagnostic screening devices This warranty is only available to the initial consumer It is not transferable If the product fails under conditions of normal use ResMed will repair or replace at its option the defective product or any of its components This Limited Warranty does not cover a any damage caused as a result of improper use abuse modification or alteration of the product b repairs carried out by any service organization that has not been expressly authorized by ResMed to perform such repairs and c any damage or cont

Download Pdf Manuals

image

Related Search

Related Contents

The micrOMEGAs user's manual, version 4.1 - LAPTh  SMSC USB2502 User's Manual  Salon Ecobat 2014 - BIPLAN®, une réponse constructive aux  Prestigio MultiPad 2 Ultra Duo 8.0 8GB Black  NTSC Instruction Manual Manuel d\instruction Manual de  "user manual"  User's Guide to: 1614 - 600 psi 3343 - 1000 psi 1381  EPSON PX-201 操作ガイド  CGP800L  Omni WA-36  

Copyright © All rights reserved.
Failed to retrieve file