Contents

1. L m R G 06 35 09 53 Less than 5m Added refrigerant when over 5 m R g Additional refrigerant to be charged L m The length of the refrigerant pipe one way D mm Liquid Side Piping Diameter 7 3 Check the Leakage Check all the joints with the leak detector or soap water point of indoor unit D C oint of outdoor unit Note In the figure A Lo stop valve B Hi stop valve C D Joints of the connecting pipe to the indoor unit Installation Manual 8 CONNECT THE DRAIN PIPE 8 1 Install the drainpipe of the indoor unit The outlet has PTI screw thread Please use easy clean drain trap supplied with the unit CAUTION e The outlet has PTI screw bread Please use sealing materials and pipe sheath fitting when connecting PVC pipes e The drain pipe of indoor unit must be insulated or it will condense dew as well as the connections of the indoor unit e PVC solvent must be used for pipe connection and make sure there is no leakage e With the connection part to the indoor unit please be noted not to impose pressure on the side of indoor unit pipes e The total length of the drain pipe when pulled out transversely shall not exceed 20m when the pipe is over long a prop stand must be installed to prevent winding e Refer to the under figures for the installation of the pipes Insulating Downward declivity material lower than 1 100 Bend x S shape Pu
2. Use the specified cable and connect tightly and clamp the cable so that cable is protected from external force If connection or fixing is not perfect it may cause heating arcing or fire at the connection Wiring routing must be properly arranged so that control board cover is fixed properly If control board cover is not fixed perfectly it will cause heat up at connection point of terminal fire or electrical shock An all pole disconnection device which has at least 3mm separation distance in all pole and a residual current device RCD with the rating of above 10mA shall be incorporated in the fixed wiring according to the national rule When carrying out piping connection take care not to let air substances go into refrigeration cycle Otherwise it will cause lower capacity abnormal high pressure in the refrigeration cycle explosion and injury Carry out the specified installation work after taking into account strong winds typhoons or earthquakes Improper installation work may result in the equipment falling and causing accidents Winer the new space If the refrigerant leaks during installation ventilate the area immediately Toxic gas may be produced if the refrigerant comes into the place contacting with fire The temperature of refrigerant circuit will be high please keep the interconnection cable away from the copper tube After completing the installation work check that the refrigerant does not leak
3. Indoor Units Notes All units split into two parts Installation Manual 1200 1400 808 400 Supply and Return air sizes are designed for Airtite series plenums e Field or installation wiring must be connected as per the connection diagram to ensure the unit performs as it is designed 808 400 Installer electrician is to ensure that when an external overload device is fitted it be calibrated or set to the maximum amp draw on the rating plate of the motor it is controlling H VAV 7 Entrances and exits for communication lines of indoor and outdoor 4 12 25 oblong suspention bolt holes Electrical parts box P 1300 306 125 FREECALL F 07 3890 8730 E info livezi com au A 1 49 Miller Street Murrarie Qld 4172 Unit mm 16 3 2 holes for air outlet duct connection Connecting point of drain pipe 24 3 2 holes for air intake duct connection Fig 5 8 Installation Manual livezi the new space Unit mm Entrances and exits for communication lines of indoor and outdoor 4 12 25 oblong suspention Air outlet bolt holes 65x13 845 28 65 65 6546 Electrical parts box 12 3 2 holes for air outlet duct connection Connecting point of drain pipe 14 3 2 holes for air intake duct connection ua 24 Lh 65 4 260 M Fig 5 9 Unit mm Entrances and exits for communication lines of indoor and outdoor 4 12 25 oblong suspention Air
4. Toxic gas may be produced if the refrigerant leaks into the room and comes into contact with a source of fire such as a fan heater stove or cooker CAUTION Ground the air conditioner Do not connect the ground wire to gas or water pipes lightning rod or a telephone ground wire Incomplete grounding may result in electric shocks Be sure to install an earth leakage breaker Failure to install an earth leakage breaker may result in electric shocks Connect the outdoor unit wires then connect the indoor unit wires You are not allow to connect the air conditioner with the power source until wiring and piping the air conditioner is done While following the instructions in this installation manual install drain piping in order to ensure proper drainage and insulate piping in order to prevent condensation Improper drain piping may result in water leakage and property damage Install the indoor and outdoor units power supply wiring and connecting wires at least 1 meter away from televisions or radios in order to prevent image interference or noise Depending on the radio waves a distance of 1 meter may not be sufficient enough to eliminate the noise The appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for the
5. outlet bolt holes 6513 845 128 D 65 65 6546 E al Ka R Electrical parts box 12 03 2 holes for air outlet duct connection Connecting point Refrigerant pipe flared of drain pipe So ecien LOCA 14 03 2 holes for air Refrigerant pipe flared F intake duct corineetion connection9 52 3 8 gt Air intake duct flange in U j di ri e e 1 o BR E NF 4 Ft 65x14 910 _65x4 260_ Fig 5 10 P 1300 306 125 FREECALL F 07 3890 8730 E info livezi com au A 1 49 Miller Street Murrarie Old 4172 we Installation Manual IVEZI the new space model i A Bi CD E S VIA Pal I x s 24 22 ras Wall or obstacle Fig 6 2 gt 30cm N Air inlet D gt Maintain channel gt 60cm D Fig 6 5 M SY Air outlet a a 3L Jen Cucine R I r Al TY TH f I TTY LLLPEF tec ill SS EEIT NOTE ER uN yee TARR UOC VE AE E e EI E N AN AII the pictures in this manual are for explanation purpose only They may be slightly different from the air conditioner you purchased depend on model The actual shape shall prevail 6 2 Moving and installation e Since the gravity center of the unit is not at its physical center so please be careful when lifting it with a sling e Never hold the inlet of the outdoor unit to prevent it from deforming e Do not touch the fan with hands or other objects e Do not lean it mor
6. p Pass the bound connecting pipe through the wall conduct from outside Be careful of the pipe allocation to do on damage to the tubing gt Connect the pipes Refer to How to Connect the pipes for details pi Expel the air with a vacuum pump Refer to How to expel the air with a vacuum pump for details Open the stop values of the outdoor unit to make the refrigerant pipe connecting the indoor unit with the outdoor unit in fluent flow m Check the leakage Check all the joints with the leak detector or soap water a Cover the joints of the connecting pipe with the soundproof insulating sheath fittings and bind it well with the tapes to prevent leakage NOTE Installation Manual CAUTION Be sure to with insulating materials cover all the exposed parts of the flare pipe joints and refrigerant pipe on the liquid side and the gas side Ensure that there is no gap between them Incomplete insulation may cause water condensation How to Connect the Pipes 1 Flaring e Cuta pipe with a pipe cutter Refer to Fig 7 1 OX X X Lean crude burr DE e inserta flare nut into a pipe and flare the pipe e Refer to Table 7 2 for the dimension of flare nut spaces Fig 7 1 Flare Dimension A Pipe Gauge Tighten Torque Flare Shape 06 35 142172Nm 144 183 8 7 176 kgf cm 9 53 i 32 7 39 9 N m 333 12 0 12 4 407 kgf cm Q12 7 i 495603 N m 504 15 4 115
7. the manifold value completely 4 When the pumping has finished close the Lo lever of the manifold valve completely and turn off the vacuum pump Evacuate to 500 microns 5 Loosen and remove the cap of stop valves A and B to open stop valve A and B completely then fasten the cap 6 Disassemble the charge hose from the service port of stop valve A and fasten the nut a Indoor unit Gas side C Outdoor unit E Liquid sid iquid side Stop valve Fig 7 6 Manifold valve Multi meter Pressure meter 76 cmHg 6 A O O Lo lever AT Mi iever Charge hose S Vacuum pump HN 77777 Lo lever Fig 7 7 3 livezi 7 2 Additional Refrigerant Charge CAUTION Refrigerant cannot be charged until field wiring has been completed Refrigerant may only be charged after performing the leak test and the vacuum pumping When charging a system care shall be taken that its maximum permissible charge is never exceeded in view of the danger of liquid hammer Charging with an unsuitable substance may cause explosions and accidents so always ensure that the appropriate refrigerant is charged Refrigerant containers shall be opened slowly Always use protective gloves and protect your eyes when charging refrigerant HM The outdoor unit is factory charged with refrigerant Calculate the added refrigerant according to the diameter and the length of the liquid side pipe of the outdoor unit indoor unit connection
8. 15 INSTALLATION NOTES PRIOR TO splitting indoor unit for installation DISCONNECT Indoor coil and return sensors T1 T2 T2B and T3 P 1300 306 125 FREECALL F 07 38908730 E info livezi com au A 1 49 Miller Street Murrarie Old 4172 ON OFF E Y X P EQ ALARM Installation Manual D Mid Coil Sensor T2 Return Air Sensor T1 Outdoor Unit Data Interconnect CT 3 core shielded TRO 3 x 0 5 mm Outdoor Unit Power Interconnect 3 x 1 0 mm Zoning Module Transformers Power Interconnect Zoning System Data Interconnect RJ12 6p6c 4 Return Air Sensor T3 lt _ Supply Air Sensor T4 13 Wives the new space Installation Manual Notes P 1300 306 125 FREECALL F 07 3890 8730 E info livezi com au A 1 49 Miller Street Murrarie Qld 4172 Wives the new space Installation Manual Notes P 1300 306 125 FREECALL F 07 3890 8730 E info livezi com au A 1 49 Miller Street Murrarie Qld 4172 15 Winer the new space Installation Manual livezi the new space Livezi Phone 1300 306 125 Fax 07 3890 8734 Web www livezi com au Email info livezi com au P 1300 306 125 FREECALL F 07 38908730 E info livezi com au A 1 49 Miller Street Murrarie Old 4172
9. 8 616 kgf cm 16 i 61 8 75 4 N m 630 186 19 0 770 kgf cm 19 97 2 118 6 N m 990 i 22 9 23 3 1210 kgf cm 2 Connect the indoor unit at first then the outdoor unit All bends must be performed using appropriate tools Deformed bends can reduce system capacity e The bend angle should not exceed 90 e Bend position is preferably in the middle of the pipe The larger the bend radius the better it is e Donot bend the pipe more than three times e When connecting the flare nut coat the flare both inside and outside with either oil or ester oil and initially tighten by hand 3 or 4 turns before tightening firmly P 1300 306 125 FREECALL F 07 38908730 E info livezi com au A 1 49 Miller Street Murrarie Old 4172 7 Winer the new space CAUTION Too large torque will harm the bell mouthing and too small will cause leakage Please determine the torque according to Table 7 3 After the connecting work is finished be sure to check that there is no gas leak How to expel the air with a vacuum pump Stop valve operation introduction 1 Opening stop valve e Remove the cap and turn the valve counter clock wise with the hexagon wrench e Turn it until the shaft stops Do not apply excessive force to the stop valve Doing so may break the valve body as the valve is not a backseat type Always use the special tool e Make sure to tighten the cap securely 2 Closing stop valve
10. Installation Manual Horizontal ig iaarge Inve IHO oor Variable A uick SIAMO oor Winer the new space CONTENTS PRECAUTIONS INSTALLATION INFORMATION ACCESSORIES INSPECTING AND HANDLING THE UNIT INDOOR UNIT INSTALLATION OUTDOOR UNIT INSTALLATION INSTALL THE CONNECTING PIPE CONNECT THE DRAIN PIPE CONTROL WIRING TEST OPERATION 1 PRECAUTIONS Be sure to conform with the local national and international laws and regulations Read PRECAUTIONS carefully before installation The following precautions include important safety items Observe them and never forget Keep this manual with the owner s manual in a handy place for future reference The safety precautions listed here are divided into two categories In either case important safety information is listed which must be read carefully WARNING Failure to observe a warning may result in death CAUTION Failure to observe a caution may result in injury or damage to the equipment After completing the installation make sure that the unit operates properly during the start up operation Please instruct the customer on how to operate the unit and keep it maintained Inform customers that they should store this installation manual along with the owner s manual for future reference WARNING Be sure only trained and qualified service personnel to install repair or service the equipment Improper installation repair and mainte
11. SENS notet I P ALH lT AJN bi IBISISISISISI lele 0000 ON OFF E Y X P EQ ALARM Installation Manual B Mid Coil Sensor T2 N Return Air Sensor T1 Outdoor Unit Data Interconnect 3 core shielded 3 x 0 5 mm Outdoor Unit Power Interconnect 3 x 1 0 mm Zoning Module Transformers Power Interconnect Zoning System Data Interconnect RJ12 6p6c c Return Air Sensor T3 Supply Air Sensor T4 P 1300 306 125 FREECALL F 07 38908730 E info livezi com au A 1 49 Miller Street Murrarie Old 4172 11 livezi the new space Outer Coil Sensor T2B SW1 ENC1 ENC2 SA SENS RET SENY naat L LP SC S2 SC S1 J1 JC H VAV 11 INSTALLATION NOTES PRIOR TO splitting indoor unit for installation DISCONNECT Indoor coil and return sensors T1 T2 T2B and T3 ON OFF E Y X P E Q ALARM Installation Manual D Mid Coil Sensor T2 8 Return Air Sensor T1 Outdoor Unit Data Interconnect 3 core shielded 3x0 5 mm Outdoor Unit Power Interconnect Zoning Module Transformers Power Interconnect Zoning System Data Interconnect RJ12 6p6c R Return Air Sensor T3 Supply Air Sensor T4 P 1300 306 125 FREECALL F 07 38908730 E info livezi com au A 1 49 Miller Street Murrarie Old 4172 12 livezi the new space Outer Coil Sensor T2B CN2 6 CNI bd IBDISISVIVIVISII Iel SW1 ENC1 ENC2 SA SENS RE Digtal 17P SC S1 J1 JC REACTOR Y H VAV
12. e Remove the cap and turn the valve clockwise with the hexagon wrench e Securely tighten the valve until the shaft contacts the main body seal e Make sure to tighten the cap securely e For the tightening torque refer to the table below Tightening torque N m Turn clockwise to close o 0 0 0 0 0 0 0 0 0 6 20 3 30 3 3 0 6 6 0 0 0 000 0 000 0 0 600 00 00000600000 0 Cap Sees Shaft valve Body valve Ene Size 2 nut Lid mor 5 4 6 6 PERA 99 53 i Hexagonal i sd ce MONCIA DD EM mm D12 7 8 1 8 9 18 22 216 13 5 16 5 i Hexagonal i 545 11 5 13 9 wrench 6mm 022 Hexagonal eve i Borsa ni GAA D25 4 T CAUTION Always use a charge hose for service port connection After tightening the cap check that no refrigerant leaks are present P 1300 306 125 FREECALL F 07 3890 8730 E info livezi com au A 1 49 Miller Street Murrarie Qld 4172 Installation Manual service port maintenance nut cap M shaft seal hexagon hole Fig 7 5 Using the Vacuum Pump 1 Loosen and remove the maintenance nuts of stop valves A and B and connect the charge hose of the manifold valve to the service port of stop valve A Be sure that stop valves A and B are both closed 2 Connect the joint of the charge hose with the vacuum pump Open the Lo lever of
13. e than 45 and do not lay it sidelong e Make concrete foundation accoding to the sepecif ications of the Fig 6 3 outdoor units Refer to Fig 6 6 e Fasten the feet of this unit with bolts firmly to prevent it from collapsing in case of earthquake or strong wind Refer toFig 6 6 NOTE All the pictures in this manual are for explanation purpose only They may be slightly different from the air conditioner you purchased depend on model The actual shape shall prevail Ov P 1300 306 125 FREECALL F 07 3890 8730 E info livezi com au A 1 49 Miller Street Murrarie Old 4172 3 livezi 7 INSTALL THE CONNECTING PIPE Check whether the height drop between the indoor unit and outdoor unit the length of refrigerant pipe and the number of the bends meet the following requirements The Max When unit is 15 25 35 Height Drop top ta TEM ETE NONE MU NM ORE TEC E 10 20 25 unit is bottom The length of When unit is 25 30 50 refrig pipe m top when outdoor 25 30 50 unit is bottom CAUTION When the pipe matrix is not observed significant reductions in system capacity and longevity should be expected 7 1 The Procedure for Connecting Pipes CAUTION m Drill a hole in the wall suitable just for the size of the wall conduit then set on the fittings such as the wall conduit and its cover DI Bind the connecting pipe and the cables together tightly with binding tapes
14. ir safety Don t install the air conditioner in the following locations mi There is petrolatum existing E Corrosive environments mi There is caustic gas the sulfide for example existing in the air near a hot spring The Volt vibrates violently in the factories In buses or cabinets In kitchen where it is full of oil gas There is strong electromagnetic wave existing There are inflammable materials or gas There is acid or alkaline liquid evaporating Other special conditions Installation Manual 2 INSTALLATION INFORMATION E To install properly please read this installation manual at first LJ The air conditioner must be installed by qualified persons E When installing the indoor unit or its tubing please follow this manual as strictly as possible E If the air conditioner is installed on a metal part of the building it must be electrically insulated according to the relevant standards to electrical appliances E When all the installation work is finished please turn on the power only after a thorough check EI We reserve the right to make changes to this document INSTALLATION ORDER Select the location Install the indoor unit Install the outdoor unit Install the connecting pipe Connect the drain pipe Wiring Test operation P 1300 306 125 FREECALL F 07 38908730 E info livezi com au A 1 49 Miller Street Murrarie Old 4172 3 Winer the new space
15. nance may result in electric shocks short circuit leaks fire or other damage to the equipment Ask your dealer for improvement repair and maintenance P 1300 306 125 FREECALL F 07 3890 8730 E info livezi com au A 1 49 Miller Street Murrarie Old 4172 Installation Manual Install strictly according to these installation instructions If installation is defective it may cause water leakage electrical shock fire When installing the unit in a small room take measures to keep refrigerant concentration from exceeding allowable safety limits in the event of refrigerant leakage Contact the place of purchase for more information Excessive refrigerant in a closed ambient can lead to oxygen deficiency Use the attached accessories parts and specified parts for installation Install at a strong and firm location which is able to withstand the set s weight If the strength is not enough or installation is not properly done the set will drop to cause injury The appliance must be installed at least 2 5m above floor The appliance shall not be installed in the laundry Before obtaining access to terminals all supply circuits must be disconnected For electrical work follow the local national wiring standard regulation and this installation instructions An independent circuit must be used If electrical circuit capacity is insufficient or there is a defect in electrical work it may cause electrical shock and or fire
16. t as deep as possible about 10cm Downward A Dy lower than 1 100 VP30 8 1 Drain Test 1 Check whether the drainpipe is unhindered 2 Newly built homes should have this test done before sheeting the ceiling P 1300 306 125 FREECALL F 07 3890 8730 E info livezi com au A 1 49 Miller Street Murrarie Qld 4172 9 we Installation Manual IVEZI the new space POWER SPECIFICATION H INV 7 H VAV 7 H INV 11 H VAV 11 H INV 15 H VAV 15 Indoor Unit Phase phase phase A phase NET Frequency amp volt 220 240V 50hz 220 240V 50hz 220 240V 50hz pe ME 3x1 0 3x1 0 3x1 0 BEEN 06 Ll ie ue Circuit Breaker A E 10 s 10 s 10 T Phase Phase i phase phase Frequency amp volt 220 240V 50hz 220 240V 50hz 220 240V 5Ohz Outdoor Unit E OS AUTE 3x2 5 3x2 5 3x2 5 Power ei 11 116 M _ I Sf es Circuit Breaker A 20 25 32 ce 3 core shielded 3 core shielded 3 core shielded Weak Electric Signal mm i wire 3x0 5 wire 3x0 5 i wire 3x0 5 10 3 Wiring Figure R i Connect Controller Central Controller Chatterbox HVAC P 1300 306 125 FREECALL F 07 3890 8730 E info livezi com au A 1 49 Miller Street Murrarie Old 4172 10 livezi H VAV 07 INSTALLATION NOTES PRIOR TO splitting indoor unit for installation DISCONNECT Indoor coil and return sensors T1 T2 T2B and T3 Outer Coil Sensor T2B S2 S1 SW1 ENC1 ENC SA SENSIRET