Home

USER MANUAL DorTag IV

image

Contents

1. buzzer Wiring from the reader is as follows BLUE Buzzer RED Buzzer BLACK CGN YELLOW Reader head GREEN Reader head Note The LED on the reader head will change from orange to green in colour with every valid tag presented Two screws and two wall plugs are supplied with the reader head for mounting onto a wall The following steps should be followed INSTALLING THE READER HEAD 1 Use the READER HEAD stencil on Pg 3 to mark the holes on the wall where the reader is to be mounted Note The center hole is for the wiring to go through The other two holes are for the wall plugs and should only be drilled deep enough to accept the wall plugs 2 Once the holes have been drilled insert wall plugs 3 Mount the reader head and fasten the screws making sure that the cable is run correctly 4 Align the LED hole on the sticker with that of the LED on the reader head and apply the sticker to the reader head 5 A version of this product allowing for the connection of 2 reader heads is available on request 6 Installing two reader heads It is possible to install two reader heads on this system Please note that this is a single door system and there is only one output relay The two heads will therefore be fitted to the ENTRY AND EXIT points on a single door 7 The two reader heads will be wired in parallel in the controller as per instructions overleaf INSTALLING THE CONTROLLER Installation of the
2. controller is slightly different to that of the reader head Instead of using the reader head stencil the CONTROLLER stencil must be used also on Pg 3 Note The controller may be mounted in a steel cabinet The wiring into the controller is as follows POWER POWER Connect the two power lines to these two contacts 12 24 AC DC CGN CGN Ground Black wire e DO DO Not used e Di D1 Not used READER READER Connect reader head loop wires to these e HEAD HEAD two contacts Yellow amp Green wires BUZZER BUZZER Buzzer negative connection Blue wire BUZZER BUZZER positive connection Red wire AUX INP AUX INP Relay switching auxiliary input Short to CGN to activate relay e e RELAY RELAY Relay normally open contacts Warning Connecting the wires incorrectly may cause permanent damage to the controller 2 DRILLING STENCIL READER STENCIL Prem R 10 oem TE CONTROLLER STENCIL 010mm emm BOTTOM TE PROGRAMMING INSTRUCTIONS TOP Note The DorTag IV Proximity Access Control Reader employs AUTO EXITING software for security reasons In any of the programming modes the controller will automatically revert back to standard operating mode if the user takes no action within 30 seconds Four different operating modes exists indicated by the display dot position POSITION 1 amp Standard Operatin
3. ESI Proximity Voiding Access Control Reader DorTag IV USER MANUAL DorTag IV Sep 2003 Revision 01 Installation InsSt UctiOFis ce e re tete et etc Dei ec 1 The reader head n tee Eee ted aem tio tais acta 1 The controller reti eee 2 Drlling stencils ise aturesit master denis sm d d d eL A 3 Programming nstructioris eite itae e beets he eine iet ei 4 Master Tag programming 5 User Tag programming 6 User Tag Voiding instruction 7 Relay Time Programming Instructions 8 Last Tag Read 8 Specifications sooo Hei rect endet Lad edet dee e ad eH god ee deba 9 Hardware eodd RC e RC qt d teet pH ete Ha 9 SOWAS i iid EE RC a Editi EE HALE E EET Ee 9 Special Features INDEX INSTALLATION INSTRUCTIONS THE READER HEAD READER HEAD LED STATUS Orange LED Normal status tag not presented Green LED Active status valid tag presented _ The reader head comes prewired with a 2m cable connected to it If the cable is to be replaced with a longer cable care must be taken to observe the polarity wiring on the
4. ad will be displayed DORTAG IV TECHNICAL SPECIFICATIONS HARDWARE Operating Voltage Average Current Consumption Maximum Current Consumption Relay Output Rating Operating Frequency Read range Reader heads Read head feeder cable length Cable Mechanical dimensions Environmental Rating Mass Operating temperature Indications 12 24V AC DC 33mA 55mA 12V 35mA 24V 24V 5A Change over contacts 125kHz 50Hz 4kHz modulation 11cm Dependant on tag type 1 2m Standard 5m max if unshielded 15m max if shielded 5 Core Controller 104mm L x 94mm W x 25mm D Reader head 75mm L x 39mm W x 15mm D Controller IP00 Reader head IP54 Controller 70g Reader head 70g 10 C to 60 Visual Bi Colour LED Audible Buzzer The unit communicates with signals between 50Hz and 4kHz and should thus be installed away from any such signals SOFTWARE Users Code Size Read Time 1000 max 64 bits 2 seconds SPECIAL FEATURES 10 Auto frequency tracking Auto exiting software Master tag learn mode Master tag voiding Individual tag voiding Entire memory voiding Auxiliary push button input Last tag read display Programmable relay output time 150ms 9 seconds
5. e User Tag that will be voided from the system when button P2 is pressed When voiding a User Tag the controller responds with a single beep and the display changes to Hoe Note 1 The display shows the memory location to be voided If is displayed that location has been voided If the display is incremented to that memory location again the location number will be displayed again but no code will be stored Note 2 The Master Tag memory location can not be accessed unless the whole memory is voided See Master Tag PROGRAMMING INSTRUCTIONS The unit responds with 3 beeps and enters Standard Operating Mode DORTAG Ill RELAY TIME PROGRAMMING INSTRUCTION PROGRAMMING FUNCTION USER ACTION CONTROLLER RESPONSE Adjusting the Relay Output Time 1 Press P1 and release 2 Continue pressing P1 to increment the timer 3 Leave the unit for 30 seconds to exit this MODE Unit responds with 3 Beeps and shows The display increments up to 2 seconds up to Bou 9 seconds This is a special setting for a 150mS PULSE OUTPUT The unit responds with 3 Beeps and enters Standard Operating Mode DORTAG lll LAST TAG READ INSTRUCTION PROGRAMMING FUNCTION USER ACTION CONTROLLER RESPONSE Looking for the Last TAG read 1 In Standard Operating Mode press and hold P2 2 Release button P2 The number of the last TAG re
6. esent each tag to the reader press button P2 on the controller to display the tag number and record this number against the name of the user in a register Repeat this exercise for all the new tags entered into the system Note Should an invalid card or tag be presented to the DorTag IV the unit will not respond with a beep the LED will remain orange in colour and no user number will appear on the controller USER TAG VOIDING INSTRUCTIONS PROGRAMMING FUNCTION USER ACTION CONTROLLER RESPONSE Voiding User Tag s 1 Present the Master Tag to the reader and keep it in the reader field for longer than 3 seconds 2 Press button P1 The left button on the controller 3 Press button P1 The left button to scroll to the User Tag number that has to be voided from the system Note By holding button P1 in the scrolling speed will increase 4 To void a User Tag from the system PRESS amp HOLD button P2 the right button 5 To exit User Tag Voiding Mode leave the controller for 30 seconds The controller initially responds with a single beep After a few seconds the controller responds with an additional 3 beeps indicating that it has entered User Tag Learn Mode The controller responds with 3 beeps and after P1 is released d BH is displayed This indicates that the controller has entered User Tag Voiding Mode The number displayed on the display is the number of th
7. g The controller will respond with 3 beeps This indicates that it has learnt the new Master Tag and exited Master Tag Learning Mode The controller is now ready for standard operation USER TAG PROGRAMMING INSTRUCTIONS PROGRAMMING FUNCTION USER ACTION CONTROLLER RESPONSE Teaching the controller a new User Tag 1 Present the Master Tag to the reader and keep it in the reader field for longer than 3 seconds Remove the Master Tag and present the new User 5 to be learnt one at a time to the reader After teaching the controller the new User Tag s present the Master Tag to the reader again to exit User Tag Learn Mode The controller initially responds with a single beep After a few seconds the controller responds with an additional 3 beeps indicating that it has entered User Tag Learn Mode 1 second after presenting a new User Tag the controller will respond with a single beep This indicates that the controller has learnt the new User Tag Note Should the controller respond with 3 beeps instead it is indicating that the 1000 user limit has been exceeded and that the controller has exited User Tag Learn Mode The controller responds with 3 beeps indicating that it has exited User Tag Learn Mode Note Should the user forget to exit User Tag Learn Mode the unit will automatically exit this mode after 30 seconds Note After completing this procedure pr
8. g Mode POSITION 2 H H User Tag Learn Mode e POSITION 3 T Voiding Mode POSITION 4 Master Tag Learn Mode The USER ACTION indicates the steps the user must take to accomplish a certain PROGRAMMING FUNCTION The CONTROLLER RESPONSE indicates the response that the controller will have to a USER ACTION IT IS RECOMMENDED THAT THE USER READ THE USER ACTIONS AND CONTROLLER RESPONSES CAREFULLY BEFORE ATTEMPTING TO PROGRAM THE CONTROLLER MASTER TAG PROGRAMMING INSTRUCTIONS PROGRAMMING FUNCTION USER ACTION CONTROLLER RESPONSE Teaching the controller a new Master Tag 1 PRESS amp HOLD button P2 The right button Note Teaching a new Master Tag can only be done in Standard Operating Mode 2 While still holding button P2 press button P1 The left button Warning On presenting a NEW MASTER TAG the entire memory will be voided and all user tags will have to be reprogrammed 3 Present the new tag to the reader This tag will become the new Master Tag The controller display changes to the last card read while pressing this button in Standard Operating Mode The controller will respond with 3 beeps immediately After releasing buttons P1 and P2 the controller display will light up displaying d B H This indicates that the controller is in Master Tag Learn Mode and that the first tag to be presented to the reader head will become the new Master Ta

Download Pdf Manuals

image

Related Search

Related Contents

Manual - USB  Wi-Fi Remote  THE USER'S GUIDE FOR THE AUTHORS  Web Energy Logger (WEL) User Guide: Rev 2.5 (Rev 3.3/4 boards  L8542874 10/2008 rev 0 UNIONE NAZIONALE  Digitus DA-11003  Leakfinder®  Pelco SPECTRA C3463M-B User's Manual  Hitachi ZX870LCH-3  Lightning Series Important Information.p65  

Copyright © All rights reserved.
Failed to retrieve file