Contents

1. User s Guide www fetco com Models CBS 2131 CBS 2132 3 liter and 1 gallon airpot brewers gt CB5 2131 Single 3 Liter Airpot Coffee Brewer 5 2132 Twin 1 Gallon Coffee Brewer NSF NOTICE TO INSTALLER Please leave this book with the machine LJUS Nor Table of Contents Contact Information Saas 2 Operating Instructions 10 Description amp Features 2 Programming operator access programming 12 2 Hot water convenience tap sss 17 Requirements 2 Adjustable spray pattern 17 Weights Capacities and Measurements Eror COJOS 17 Electrical Configuration and Brewing Efficiency 3 Airpot use instructions and cleaning 18 Mestalla tOM o Parts diagrams bill of materials lists 22 Accessing batch and programming menu screens S WING ae 33 FETCOG LUXUSG EXTRACTOR INTERMITTENT BREW and Driven To Innovation are trademarks or trade names of Food Equipment Technologies Company 2012
2. 8 SCREW SIZE W NEOPRENE BONDED SEAL 1084 00006 00 NUT 8 32 18 8 HEX MACHINE SCREW 1102 00113 00 SWITCH REED ASSEMBLY 1029 00006 00 84 40 NYLON FINGER NUT 1071 00010 00 FAUCET HPSC BR 8 REGULAR HANDLE 1031 00003 00 FITTING BARB 3 8 ID x 1 4 FPT 1057 00043 00 SOLENOID VALVE SINGLE 180 DEG 24VDC 1083 00005 00 1082 00010 00 1102 00164 00 1104 00043 00 1112 00163 00 1083 0001 1 00 1082 00023 00 WASHER 4 18 8 INTERNAL TOOTH LOCKWASHER SCREW 4 10 ZINC PLATED PAN PHILLIPS MACHINE ADAPTER ASSY 3 4 BSP X 1 4 SAE FLARE TANK ASSY 2300W 120VAC CBS 2131 GROMMETS WELDMENT TANK LOCK BRACKET CBS 2100 WASHER 8 SCREW SIZE INTERNAL TOOTH LOCK SCREW 88 32 X 3 8 TRUSS HD PHIL MACHINE 1102 00187 00 PUMP BRACKET AND HOLDER ASSEMBLY 1086 00003 00 UNICLAMP 15 9 HOSE OD CLAMP 1025 00063 00 TUBE 5 8 OD X 3 8 X 8 50 LG 1102 00181 00 ASSEMBLY BACK PANEL CBS 2130 1082 00017 00 SCREW 6 32 X 1 2 TRUSS HD PHIL MACHINE 1023 00147 00 PLUG TANK SERVICE DRAIN FOR 18GA AND UP BODY 1024 00040 00 CARD PLUG HWD 2100 1102 00190 00 ASSEMBLY FRONT PANEL CBS 2100 1082 00058 00 SCREW 8 32 X 5 8 FLAT HD PH 18 8 SS 1102 00182 00 ASSEMBLY LOCATOR CBS 2130 1082 00065 00 SCREW 728 32 X 1 1 2 FLAT HD PH 18 8 SS 1023 00159 00 CORNER INSERT 1112 00168 00 WELDMENT TOP COVER CBS 2131 1402 00034 00 HARNESS HIGH AMP CBS 2131 1402 00035 00 HARNESS LOW AMP CBS 2131 B012280B1 BB ASSY 13 X5 280 DIA HOLE BLK HNDL
3. 1073 00008 00 FOOT CBS 2130 1082 00066 00 SCREW 1 4 20 X 1 2 SOCKED HD CUP 1024 00052 00 CONNECTOR BREW PUMP 1086 00002 00 CLAMP HOSE SIZE G NYLON 1055 00001 00 PUMP HOT LIQUID 1025 00012 00 TUBE 5 16 OD X 3 16 ID X 11 00 LG 1025 00061 00 TUBE 9 16 OD X 5 16 ID X 2 75 LG 1029 00002 00 FITTING HOSE BARB TEE SIZE 3 8 NYLON 1025 00058 00 TUBE 9 16 OD X 5 16 ID X 25 00 LG 1025 00060 00 TUBE 9 16 OD X 5 16 X 3 25 LG 1083 00009 00 WASHER 6 SCREW INTL LOCKWASHER 1084 00010 00 NUT HEX 86 32 UNDERSIZED ZINC PLATED 1025 00006 00 TUBE VENT SUPPORT 5 16 OD X 3 16 ID X 1 1025 00064 00 TUBE 1 2 OD X 1 4 ID X 9 00 LG 1013 00073 00 TUBE 5 16 OD 1 LONG 1046 00006 00 LABEL WARNING HOT WATER FAUCET 1044 00004 00 LABEL DANGER HIGH VOLTAGE 1046 00003 00 LABEL CSD WARNING 1 5 X 5 0 1 NI l N Ob WN 09 NO gt OO 4 OI 01 B GO RO 1 OI 1 0 4 OIOINI Od 01 B IGO N 54 25 d AEN AR WP EF Nr Drawing 1104 00043 00 TANK ASSY 2300W 120VAC CBS 2
4. 197 4 m BREW AT TEMP OFF USER SELECTABLE Allows brewing at any temperature above 179 F 82 C Not recommended 14 Programming Factory set Programming Range Items Default display 1 3 Reset HErrors must be so iris e G corrected cleared SD gt Brewer Setup upload e From SD to B SD2 Brewer eFromBtoSD Brewer gt SD O UPLOAD LOGO Upload Logo Are you sure Reset to Default Reset to default Are you a YES NO All Counters Error Codes Copy Program Please insert SD card with the setup data Setup download Please insert SD card with sufficient space 22GB Please insert SD Upload Logo card with logo file Completely overwrites all user setup incl user logo Res to Factory Left Brews Left Brew activated Left Brew liters Left Bypass Activated Left Bypass liters Right Brews Right Brew activated Right Brew liters Right Bypass Activated Right Bypass liters Fill valve Activated Fill Valve liters Heater Activated Heater on time Touch To Return Reset All Counters Reset All Are you sure Counters e Display Counters OR e Reset Counters Resetting will restart counter from zero Counters Display Total Counters Counters O O O O O O e Reset Counters SW ver 1 0 2A HW ver Displays firmware BL ver 1 0 1 version QP ver 4 5 01 UPDATE Firmware uplo
5. B012280B1 BB ASSY 13 5 280 DIA HOLE BLK HNDL 1086 00002 00 CLAMP HOSE SIZE G NYLON 1083 00009 00 WASHER 86 SCREW INTL LOCKWASHER 1084 00010 00 NUT HEX 86 32 UNDERSIZED ZINC PLATED 1025 00006 00 TUBE VENT SUPPORT 5 16 OD X 3 16 ID X 1 1025 00064 00 TUBE 1 2 OD X 1 4 ID X 9 00 LG 1013 00073 00 TUBE 5 16 OD 1 LONG 1073 00008 00 FOOT CBS 2130 1082 00066 00 SCREW 1 4 20 X 1 2 SOCKED HD CUP 0 2 01 TOE gt N GO OO IN 7 O O NIDA CO CO IN gt O CO NI O O O OI OO DO gt SS 27 AR 4 29 1 1101 00131 00 5 2132 2 X3kW 240VAC 1gal BYPASS Ref Qy 1 1 1111 00029 00 WELDMENT BODY CBS 2132 EDGE PROTECTOR 7 00 LG CBS 2130 3 6 1086 00004 00 BUSHING SNAP 1 MOUNTING HOLE 4 2 1024 00017 00 O RING 3 739 ID X 0 070 CS 70 DURO BUNA 6 8 1083 00010 00 WASHER 10 SCREW W NEOPRENE BONDED 8 2 110200113 00 SWITCH REED ASSEMBLY 9 6 1029 00006 00 4 40 NYLON FINGER NUT 13 13 LET SE 16 1 1102 00164 00 ADAPTER ASSY 3 4 BSP X 1 4 SAE FLARE 21 1 1102 00187 00 PUMP BRACKET AND HOLDER ASSEMBLY 22 2 10240004800 YCONNECTOR TUBE 5 16 OD X 3 16 ID X 11 00 LG FITTING HOSE BARB TEE SIZE 3 8 NYLON TUBE 9 16 OD X 5 16 ID X 3 25 LG TUBE 9 16 OD
6. X 5 16 ID X 2 75 LG TUBE 9 16 OD X 5 16 ID X 25 00 LG TUBE 5 8 OD X 3 8 ID X 8 50 LG SCREW 6 32 X 1 2 TRUSS HD PHIL MACHINE SCREW 88 32 X 1 1 2 FLAT HD PH 18 8 SS 40 1 1112 00167 00 WELDMENT TOP COVER CBS 21322 WASHER 1 4 SCREW SIZE SPRING LOCK 45 1 1402 00032 00 HARNESS HIGH CBS 2132 46 1 140200033 00 HARNESS LOW 5 2132 1 0 BB ASSY 13 X5 280 DIA HOLE BLK HNDL CLAMP HOSE SIZE G NYLON 49 1 1083 00009 00 WASHER 6 SCREW INTL TOOTH LOCKWASHER 50 1 1084 00010 00 NUT HEX 46 32 UNDERSIZED ZINC PLATED TUBE VENT SUPPORT 5 16 OD X 3 16 ID X 1 TUBE 5 16 OD 1 LONG 30 N 1 d 3 d e Pu tou K dU TANK ASSY 2 X 3000W 240VAC 5 2132 GROMMETS PART NO DESCRIPTION WELDMENT TANK CBS 2132e GROMMET DESIGN GROMMET SILICONE LL amp TEMP PROBES GROMMET SILICONE 11 4mm ID 1102 00183 00 PCSD Pump Spray Housing Assembly Parts QTY PART NO DESCRIPTION SPRAY HOUSING ASSY amp 1 1 0 1024 00045 00 023 00164 00 1 SCREW M3 9x13 CHEESE PH 4 2 1082 00068 00 70 1102 00019 00 CASCADE SPRAY DOME ASSEMBLY Complete CBS 2130 Spray Housing Assembly Part number 1102 00183 00 Description BB WLDMNT 13 X5 W 9 280 HOLE Never strike or hit a brewbasket against any hard surfa
7. coffee dispenser cleaner such as URNEX TABZ DIP IT or Squeak Clean 2 Carefully Follow the instructions supplied with the cleaning product 3 Never use spray cleaners solvent solvent based cleaner or petroleum based polish anywhere on dispensers Safety notes Professional installation is required This appliance is manufactured for commercial use only Operation requirements and maintenance for commercial cooking appliances differ from household appliances Operators must be trained for this equipment and must understand the use maintenance and hazards Do not attempt to move hot beverage equipment once it is filled Drain equipment before moving CBS 2130 series coffee brewers prepare up to 3 liters 1 gallon of coffee or tea in a single batch using very hot water For safety the brew basket is locked and may be serviced 5 5 minutes after starting the brew The factory set brew default time is 5 5 minutes with the brew basket locked for safety from start of brew gt Never attempt to defeat or override a brew basket locking feature Warning Turn off power before any cleaning procedure including wiping the exterior for appearance reasons Dry the exterior especially the face panel before turning on power Do not apply any type of spray cleaner on the face panel of this equipment Never use solvent or solvent based cleaner or petroleum based polish anywhere on this equipment Dry the face of the touch pad before turning
8. on power Do not electrically energize this equipment or attempt operation without all covers in place and all screws fastened Unplug machine before disassembly or servicing EON Operating Instructions gt Quick brewer setup NOTES Install plumbing and electrical utilities See Installation Section in this guide Turn rear power switch ON Located on back lower right side Brewer hot water tank will fill in 4 8 minutes Ready screen will display FILLING Heater s activate when tank is full Ready screen will display HEATING Initial heating will be 15 30 minutes Tank displays READY when filled amp 200 F 93 C is reached Place dispenser under brewbasket s to collect any overflow and condensate Brewer is ready to brew when READY is displayed Best results if brewer remains ON Brewing gt To brew a single 3 liter coffee batch using default recipe NOTES FETCO CBS 2130 series equipment is factory calibrated and preloaded with recipes and is ready to brew Place 13 X5 paper filter in brew basket FETCO Product F002 or any 13 X5 Add 3 8 ounces 85 227 g of ground coffee Weights given are only suggested Insert loaded brewbasket into brewer rails Brewbasket s must be in place Have empty dispenser under brewbasket Use the convenient locator guide Tap READY screen to enter
9. setting for all batches is WIDE The brewer software calculates and corrects to achieve proper volume based on the flow rate changes of the spray pattern Error Codes Code Description 00000 Possible Cause Corrective Action How to Clear Error Codes 050 Shorted temperature probe Probe failure Replace probe 60086 Check all connections Open temperature probe connection or Replace probe if CLEAR FAULT make probe failure y repairs as required Watch for short potting Below is the only way to Initial Fill Error Initial fill Water supply flow during brew cycle cereri coe time was more than 4 1 Ent minutes after power up rate is too low Investigate cause of low flow Enter rate Clogged water filter PROGRAMMING rap Gn Watch for short potting Water supply flow during brew cycle 2 Scroll left to OTHER Tank did not refill within 3 minutes rate is too low Investigate cause of low E rate Clogged water filter 3 Scroll down to Check inside of machine for il 102 Unwanted fill tank fitting or leak valve 4 Scroll down to Display Clean check all Errors Probe fouled or 103 Liquid level probe fault bon connections Replace probe Shorts if necessary 5 Scroll left to Reset Errors Heater open high limit SSR High Limit Check and replace heating thermostat or Solid State or heating laminis PROCESAL Relay SSR fault element failure y 6 Scro
10. 005 00 1082 00010 00 1102 00164 00 1104 00044 00 1112 00163 00 1083 00011 00 1082 00023 00 1102 00187 00 1024 00052 00 WASHER 4 18 8 INTERNAL LOCKWASHER SCREW 4 10 ZINC PLATED PAN PHILLIPS MACHINE ADAPTER ASSY 3 4 BSP X 1 4 SAE FLARE TANK ASSY 2 X 3000W 240VAC 5 2132 GROMMETS WELDMENT TANK LOCK BRACKET CBS 2100 WASHER 8 SCREW SIZE INTERNAL TOOTH LOCK SCREW 8 32 X 3 8 TRUSS HD PHIL MACHINE PUMP BRACKET AND HOLDER ASSEMBLY CONNECTOR BREW PUMP 1055 00001 00 PUMP HOT LIQUID 1086 00003 00 UNICLAMP 15 9 HOSE OD CLAMP 1025 00012 00 TUBE 5 16 OD X 3 16 ID X 11 00 LG 1029 00002 00 FITTING HOSE BARB TEE SIZE 3 8 NYLON 1025 00060 00 TUBE 9 16 0D X 5 16 ID X 3 25 LG 1025 00061 00 TUBE 9 16 0D X 5 16 ID X 2 75 LG 1025 00058 00 TUBE 9 16 OD X 5 16 ID X 25 00 LG 1025 00063 00 TUBE 5 8 OD X 3 8 ID X 8 50 LG 1102 00181 00 ASSEMBLY BACK PANEL CBS 2130 1082 00017 00 SCREW 6 32 X 1 2 TRUSS HD PHIL MACHINE 1023 00147 00 PLUG TANK SERVICE DRAIN FOR 18GA AND UP BODY 1024 00040 00 CARD PLUG HWD 2100 1102 00190 00 ASSEMBLY FRONT PANEL CBS 2100 1082 00058 00 SCREW 8 32 X 5 8 FLAT HD PH 18 8 55 1102 00182 00 ASSEMBLY LOCATOR CBS 2130 1082 00065 00 SCREW 48 32 X 1 1 2 FLAT HD PH 18 8 SS 1023 00159 00 CORNER INSERT 1112 00167 00 WELDMENT TOP COVER CBS 2132 1402 00032 00 HARNESS HIGH CBS 2132 1402 00033 00 HARNESS LOW AMP CBS 2132
11. 131 GROMMETS 1083 00009 00 WASHER 46 SCREW INTL LOCKWASHER THERMOSTAT SINGLE SHOT 240V 40A 1084 00010 00 NUT HEX 46 32 UNDERSIZED ZINC PLATED 1003 00005 00 BRACKET ONE SHOT THERMOSTAT 1052 00014 00 ASSEMBLY RELAY SOLID STATE 25A 230V 1107 00021 00 HEATER ASSEMBLY IMMERSION 1500W 120VAC 1107 00022 00 HEATER ASSEMBLY IMMERSION 1700W 120VAC 1 26 1081 00042 00 STANDOFF 6 32 1 25 LG 1 4 HEX WIDTH 1107 00019 00 HEATER ASSEMBLY IMMERSION 2300W 120VAC 1 31 3 3 31 31 31 3 3 3 31 3 31 3 N Go No CO Ni Od 01 20 NN SN N m es ER 5 x _ 27 Drawing 1101 00132 00 CBS 2132 3 Liter BYPASS 2 X 3kW 240VAC DESCRIPTION 1111 00029 00 WELDMENT BODY CBS 2132 1024 00049 00 EDGE PROTECTOR 7 00 LG CBS 2130 6 1086 00004 00 BUSHING SNAP 1 MOUNTING HOLE 1024 00017 00 O RING 3 739 ID X 0 070 CS 70 DURO BUNA 1102 00183 00 SPRAY HOUSING ASSEMBLY CBS 2130 8 1083 00010 00 WASHER 8 SCREW SIZE W NEOPRENE BONDED SEAL 1084 00006 00 NUT 8 32 18 8 HEX MACHINE SCREW 1102 00113 00 SWITCH REED ASSEMBLY 1029 00006 00 84 40 NYLON FINGER NUT 1071 00010 00 FAUCET HPSC BR 8 REGULAR HANDLE 1031 00003 00 FITTING BARB 3 8 ID x 1 4 1057 00043 00 SOLENOID VALVE SINGLE 180 DEG 24VDC 1083 00
12. Food Equipment Technologies Company P114 1 October 2012 Contact Information Phone 800 338 2699 US 8 Canada Food Equipment Technologies Company 847 719 3000 600 Rose Road Fax 847 719 3001 Lake Zurich e IL 60047 0429 USA Email sales fetco com Internet www fetco com techsupport fetco com Description amp Features The CBS 2130 Series coffee brewers feature our universal spray over technology which works like this The following variables are programmed for each batch size Brew volume Prewet percent Percentage of the brew volume Brew time Prewet delay The time between prewetting and the brew cycle Adjustable number of pulses Bypass percent Percentage of the brew volume Drip delay The time between the end of the brew cycle to Three selectable spray patterns empty the brewbasket and end of the brewing cycle Using these variables the software calculates how much water to use for prewetting bypass optional and brewing The total brew time is divided into several cycles Within these cycles the software calculates how long to spray water over the coffee grounds and how long to pause before the next cycle begins The optional bypass valve opens at the beginning of the brew cycle and dispenses the correct amount of water all at once Spray pattern into brew basket may be user set for perfect penetration Features Touchscreen Operation Pump circuit calibration on star
13. GER NUT 11 1 1031 00003 00 FITTING BARB 3 810 1 4 FPT 12 1 1057 00043 00 SOLENOID VALVE SINGLE 180 DEG 24VDC a a a 00 1 1083 00005 00 WASHER 4 18 8 INTERNAL LOCKWASHER 1082 00010 00 SCREW 4 10 ZINC PLATED PAN PHILLIPS MACHINE 1 1 22 9 1086 00003 00 UNICLAMP 15 9 HOSE OD CLAMP 0 TUBE 5 8 OD X 3 8 ID X 8 50 LG BB ASSY 13 X5 280 DIA HOLE BLK HNDL CLAMP HOSE SIZE G NYLON TUBE 5 16 OD X 3 16 ID X 11 00 LG TUBE 9 16 OD X 5 16 ID X 2 75 LG FITTING HOSE BARB TEE SIZE 3 8 NYLON TUBE 9 16 OD X 5 16 ID X 25 00 LG TUBE 9 16 OD X 5 16 ID X 3 25 LG TUBE VENT SUPPORT 5 16 OD X 3 16 ID X 1 2 LG TUBE 5 16 OD 1 LONG LABEL CSD WARNING 1 5 X 5 0 23 7 y A i a OO gt a 04 00045 00 1101 00131 00 101 00138 00 1104 00046 00 101 00139 00 1104 00047 00 1 sene 191 00140 00 1104 00048 00 TANK ASST 3000W 240VAC 85 2131 GROMMETS 24 rawing 1101 00127 00 CBS 2131ASSEMBLY 3 Liter NO BYPASS 2 3kW 120VAC PART NO DESCRIPTION 1111 00030 00 WELDMENT BODY CBS 2131 1024 00049 00 EDGE PROTECTOR 7 00 LG CBS 2130 1086 00004 00 BUSHING SNAP 1 MOUNTING HOLE 1024 00017 00 O RING 3 739 ID X 0 070 CS 70 DURO BUNA 1102 00183 00 SPRAY HOUSING ASSEMBLY 5 2130 1083 00010 00 WASHER
14. IE 8 ANK s 24V 2 A or 50 O RED BREW PUMP RIGHT 3 FILL VALVE 24VDC E X 3 BB SENSOR RIGHT 8 M E ELE 57 BYPASS PUMP option RIGHT 4 TANK GND LEVEL PROBE GREEN BLACK TEMP PROBE BLACK BROWN cu Cem RED RED RED 5V 24V E na mE BYPASSR 8 c 2 3 RED BREW PUMP 1 6 2 2 d a m RED WHITE 2 BBSL GRAY WHITE a m RED j 8 1 qua PAS option LEFT 2 BBLOCKS ME TOLERANCES REVISIONS FOOD EQUIPMENT TECHNOLOGY COMPANY OPTION CAKE ZURICH IL 60047 E EXCEPT AS NOTED ku PHONE 847 719 3000 FAX 847 719 3001 ES 06 07 12 DWG NAME SD CARD 005 WIRING CBS 2132 L1 L2 GND 2 HEATERS READER FRACTIONAL ES 10 22 12 E 0 APP D DATE ek 0 PROPRIETARY AND CONFIDENTIAL THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF FETCO ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF FETCO IS PROHIBITED
15. S 2131 1 gallon WATER SUPPLY INLET CBS 2132 23 113 1gallon 1 3 4 8 ota 9 2 3 13 16 9 1 1 WATER SUPPLY INLET 1 16 Rough in CBS 2132 Twin station 1 gallon version Installation For Qualified Service Technicians Only Guide to A Successful Installation If not installed correctly by qualified personnel the brewer will not operate properly and damage may result Damages resulting from improper installation are not covered by the warranty and will void the warranty Here are the key points to consider before installation Electrical 4 FETCO brewers require an electrical ground wire Installation without grounding is dangerous Verify voltages polarity circuits and circuit breaker access before attaching equipment The electrical diagram is located in the Users Guide and online at www fetco com The installation must comply with applicable federal state and local codes having jurisdiction at your location Check with your local inspectors to determine what codes will apply Plumbing All installations must comply with applicable federal state or local plumbing codes An inline water filter is highly recommended It should be installed after a water shutoff valve and in a position to facilitate filter replacement The water line and newly installed filter cartage must be flushed thoroughly prior to co
16. Show how to attach covers close and or secure the dispensers for transporting Show the location and operation of the water shut off valve as well as the circuit breaker for the brewer Steam from the tank will form condensation in the vent tubes This condensation will drip into and then out of the brew baskets Up to 1 4 cup 118cc discharging overnight is possible Place an appropriate container under each brew basket when not in use 7 Werecommend leaving the power to the brewer on overnight The water tank is well insulated and very little electricity is used to keep the tank hot Leaving the brewer in the ON position will also avoid delays at the beginning of shifts for the brewer to reach operating temperature ova Cleaning amp Maintenance After Each Brew 1 Dispose of grounds and rinse brew basket 2 Never strike a brewbasket or hit it against a hard surface This will damage the brew cone and may damage the brewbasket support rails 3 Rinse dispensers before reuse Every Day 1 Wash brew basket with hot sudsy water 2 Pull CSD from the spray head it is magnetically attached Use gloves or a heavy towel Wash off any film and reattach Use vinegar if limescale filming is present 3 Clean dispensers with hot suds water and a brush rinse and air dry 4 Use only a soft cloth and hot suds on the outside to avoid scratches Never use abrasives which will scratch surface Weekly 1 Use a commercial
17. UTPUTS OTHER Items for Programming i Items for Programming 1 Items for Programming 1 02 d Items for Programming Batch LEFT TankTemp Display Inputs LeftPump Error Codes Batch2Left Brew At Temp Calib Touch Scr LBypassPump Display Errors _ Batch 3 Left Unit of Meas RightPump Reset Errors 0006 Batch 4Left Volume R Bypass Pump Program _ Batch 1 RIGHT ECOMode FromSDtoB _ Batch 2 Right Logo Timeout Heater Batch 3Right Brew B Sensor Upload Logo _ Batch Copy 1 gallon airpot version Menu Features Batch Parameters PROGRAM Programming Items Batch 1 LEFT Factory set Default Programming Range Notes e Batch Summary Display Summary e Batch Name Regular 1 16 Choose from list Regular 1 16 Regular1 OR Write any name 3 05 liter Batch Volume 1 0 4 7 w gt 4 00 mm ss e Brew Time 4 00 mm ss 2 00 10 00 Wide e Spray Pattern Wide L Wide Middle Narrow 8 e Nr Of Pulses 8 1 30 0 90 e Prewet Perc 090 0 0 15 1 30 mm ss e Prewet Delay 0 00 mm ss 1 0 00 1 00 0 90 Bypass option is only on 1 e Bypass Perc 090 Ll gallon airpot version 1 30 mm ss e Drip Delay 1 30 mm ss 0 30 5 00 Batch 2 Left Batch 2 4 Right and Batch2 4 Left may be individually selecte
18. VAC 3 wires H elol g HM ej N z2 e GROUND LUG lt L2 NOT USED For 120 volt GROUND WIRE IMUST BE INSTALLED CORD WITH NEMA 5 15P or 5 20P or without PLUG Factory Configuration Terminal block for professional installation N 2 1 20V N NOT USED 208 240V NEW FETCO CONFIGURATIION METHOD GROUND LUG GROUND WIRE IMUST BE INSTALLED Final Setup Final Setup Turn on incoming water supply line and carefully inspect both inside and outside of the brewer for leaks in all fittings and tubes Turn on power Press the brewer s main power switch located on the lower right of the back of the equipment Pre check will display DC voltage calibration for pumps is running Please wait Calibration is successfully done 15 seconds The water tank will begin filling FETCO Home Screen 1 will read FILLING When the water level rises and is sensed by the probe at the top of the tank the heaters will activate Heaters are automatically disabled until the tank is full While the water is heating Screen 2 HEATING will display and the actual water temperature will be displayed After the water has reached the set temperature Screen 3 will display READY Review the Operating Instructions Brew one full batch water only on each side to confirm proper fill levels The brewer is factory set with water only no coffee to d
19. ad e Firmware Version Software type Firmware Version e Update E Firmware UPDATE Please insert SD card with 0 YES NO the firmware file ERROR CODES Error code 50 Shorted temperature probe Error code 51 Open temperature probe Error code 100 Initial Fill Error Initial fill time was more than 4 minutes after power up Error code 101 Error on refill Error code 102 Unwanted fill possible leak Error code 103 Liquid level probe fault Error code 201 Heater open high limit thermostat or Solid State Relay SSR fault 15 Items Default display TEST Runs pump to verify Left Pump e Left Pump Test Press to test Press To Test flow Have container under brewbasket Calibrate Factory or service use L Pump Flow Rate for flow rate gt Runs pump to verify L Bypass Pump Press to test Press To Test flow Have container under brewbasket L BP Pump Calibrate 0 or service use Calib Flow Rate flow rate TEST Runs pump to verify Right Pump Right Pump Test Press to test Press To Test flow Have container under brewbasket Calibrate Factory or service use Flow Rate for flow rate TEST gt Runs pump to verify R Bypass Pump 2 Press to test Press To Test flow Have container under brewbasket e R BP Pump Calibrate Factory or service use Calib Flow Rate for f
20. alibration is successfully done lt FETCO home screen will display on completion Batch selection and brew operation menu screens Tap FETCO HOME SCREEN to enter batch selection screen Tap left or right side batches Hold down batch selector pennant to begin brew FETCO home screen Programming menu screens MAIN POWER SWITCH Located to lower right side of back panel FETCO home screen e First message on touchscreen display at powerup This shows Please wait only at POWER ON when ON OFF The software is analyzing and correcting any variations as a quality control feature Calibration is successfully done lt FETCO home screen will display on completion From power Turn main power switch to Touch screen will illuminate and pump voltage calibration will display When Complete FETCO HOME SCREEN will display Immediately touch and hold finger to enter programming In 5 8 seconds PROGRAMMING screen will appear Operator Training Review the operating procedures with whoever will be using the brewer Pay particular attention to the following areas 1 Always pre heat the dispensers before the first use of each day by filling them half way with hot water and letting them stand for at least 5 minutes Don t remove the brew basket from a coffee brewer until it has stopped dripping Make sure the dispenser is empty before brewing into it
21. ce 32 REVISIONS REV DAE ECONO DESCRIPTION B 06 07 12 N A ORIGINAL To WW B 08 21 12 N A GND WIRE ADDED REVISED Slo RV C 10 22 12 N A REVISED WIRE CONNECTION GREEN gt gt 2 2 0 O O nO ro CEN AN NN C J a 0 POWER SWITCH r 24V BREW PUMP RIGHT 3 BB SENSOR RIGHT BYPASS PUMP option RIGHT H Tony E TOLERANCES REVISIONS FOOD EQUIPMENT TECHNOLOGY COMPANY 7 EXCEPT AS NOTED KZ RA PHONE BAJ 7199060 FAX 847 719 3001 DECIMAL 06 07 12 Lw DWG NAME ao m 08 21 12 WIRING CBS 2131 L1 N GND 1 HEATER DRA B SCALE MATERIAL 10 22 12 PRN PY SAE yya NA o ok APP D DATE gans ek 9 1401 00042 00 FILL VALVE 6 RED BLACK LEVEL PROBE BLACK TEMP PROBE BLACK 51 0 Lo z gt o 658 GREEN T1 BBLOCKS OPTION WWW FETCO COM PROPRIETARY AND CONFIDENTIAL THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF FETCO ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF FETCO IS PROHIBITED REVISIONS REV DAME ECONO DESCRIPTION BF B 07 02 12 N A SECOND SSR ADDED B 10 22 12 N A REVISED WIRE CONNECTION RED GROUND S C
22. d 1 gallon brewers Total Weight Brewer Brewer amp Filled Dispenser CBS 2131 22 x 16 5 8 x 22 7 8 3 liter 57 8 42 3 58 1 CBS 2131 22 16 5 8 x 22 7 8 gallon 57 8 x42 3x58 1cm CBS 2132 24 2278 23 3 liter 62 2 x 58 1 x 58 4cm CBS 2132 24 22 23 gallon 62 2 x 58 1 x 58 4cm Shipping Weight Shipping Dimensions Electrical Configuration and Brewing Efficiency Electrical Configurations CBS 2131 3 liter version Configuration Heater Electrical Maximum Amp Gallon Hour Code Configuration Bypass i voltage Phase Connection n Draw 3 liters per batch E213103 1X1 5 kW 100 120 NEMA 5 15P 10 9 13 0 3 9 gal 14 8 lit E213104 1 1 7 kW 100 120 5 15 12 3 14 7 4 4 gal 16 7 lit E213101 1 X 2 3 kW 100 120 NEMA 5 20P 16 5 19 7 5 8 gal 22 lit E213105 1 2 3 kW 200 240 Cord No Plug 8 5 10 1 5 8 gal 22 lit E213108 1X3 0 kW 200 240 Cord No Plug 10 9 13 0 7 7 gal 29 1 lit Electrical Configurations CBS 2132 3 liter version Configuration Heater Electrical Maximum Gallon Hour Code Configuration Bypass voltage Hass Connection Amp Draw 3 liters per batch E213201 2 X 2 3 kW 200 240 Terminal Block 16 5 19 7 11 5 gal 43 5 lit E213202 2 3 0 kW 200 240 Terminal Block 21 3 25 5 14 0 gal 53 lit Electrical Configurations CBS 2131 1 gallo
23. d or entirely deleted ON e Batch ON OFF ON 0 94 4 73 e Batch Summary Display Summary e Batch Name Regular 1 Regular 1 16 Write own name 3 03 liter ON e Batch Volume 0 94 4 73 i r 4 00 mm ss Brew Time 4 00 mm ss 1 2 00 10 00 Wide e Spray Pattern Wide Wide Middle Narrow 8 e Nr Of Pulses 8 1 10 0 90 e Prewet Perc 0 0 15 0 00 mm ss e Prewet Delay 0 00 mm ss 0 00 1 00 O 90 Bypass option is only 1 e Bypass Perc 090 Li oh 1 30 mm ss e Drip Delay 1 30 mm ss 0 30 5 00 Batch 3 Left See Batch 2 Left Batch 4 Left See Batch 2 Left Batch 1 Right See Batch 1 Left Batch 2 Right See Batch 2 Left Batch 3 Right See Batch 2 Left Batch 4 Right See Batch 2 Left Batch Copy Copy From Batch L1 L1 L4 R1 R4 Copy To Batch L1 L1 L4 R1 R4 5 x example YES NO Batch 184 cannot be disabled CBS 2132 Batch 1 cannot be disabled CBS 2131 Batch can be disabled and removed from display 13 Programmin Factory set Programming Range GENERAL 9 9 ry Items Default display 200 200 OFF allows Brew at Temp brewing at any AUTO temperature ree j Gallons Lit 1 00 mm ss Logo Timeout 1 00 mm ss Brew B Sensor NORMAL ELE Programming Facto
24. equipment Never use cleaners or polishes formulated with the solvent diethylene glycol butyl ether DGBE on any equipment remain in tank 2130 COFFEE BREWING SYSTEM Complete Commercial Parts Listing For CBS 2131 and CBS 2132 Model Range Includes types for the 5 liter and 1 gallon airpot dispensers NEW September 2012 Please see our website www fetco com for the most up to date listings and additional parts and service information Designs materials specifications physical dimensions firmware and software protocol for equipment or replacement parts are subject to change without notice 21 Parts diagrams bill of materials lists A i m 4 me en Vm om din O d 6 FINAL ASSY NO TANK 0 1104 00048 00 00135 00 TANK ASSY DESCRIPTION ASST 23008 240VAC 85 2131 GROMMETS TANK ASSY 30008 240VAC 85 2131 GROMMETS 22 Ref Qty 1 1 1111 00030 00_ WELDMENT BODY 5 2131 gt O 4 1 1024 00017 00 O RING 3 739 ID X 0 070 CS 70 DURO BUNA FDA 5 1 110200183 00 SPRAY HOUSING ASSEMBLY CBS 2130 6 4 1083 00010 00 WASHER 10 SCREW W NEOPRENE BONDED SEAL 7 8 1084 00006 00 NUT 8 32 18 8 MACHINE SCREW 8 1 1102 00113 00 SWITCH REED ASSEMBLY 9 4 10290000000 440 NYLON FIN
25. gs are adjustable and the names can be changed Batch 1 amp 4 cannot be disabled Accessing Menu screen displayed Programming menu screens Accessing Programming Menu screen displayed Turn unit OFF m CBS 2130 After 10 second delay acu lt line is programming Pre check will display DC Sd voltage calibration for pumps 15 zeuen voe Second line displays E T running Please wait Calibration items for programming is successfully done Turn unit ON 2012 all rights HOME Screen on left will reserved appear Right and left hand arrows Will scroll to the screens that Ready Touch display Program General O Heating screen Immediately place finger 00 Inputs Outputs and Other screen and HOLD Screen on right will appear Down arrow enters the gt FETCO HOME screen individual programming items shown below Programming category screens Menu Tree Programming category screens To enter Turn unit OFF After 10 second delay turn unit ON Home Screen will appear Immediately place finger on screen and HOLD PROGRAM Screen first below will appear Use right left and down arrows to travel through programming EXIT saves settings Batchilett gt Programming Category E Programming Category Programming Category li Programming Category Programming Category PROGRAM GENERAL INPUTS O
26. ispense the correct amount of water If the actual volume is slightly different from the programmed volume fine tuning the brewer may be necessary See Calibrate Pumps in the OUTPUT section in the PROGRAMMING section Re attach the covers after one final inspection for leaks Look closely in the top of the brewer section at the dispense fittings during this inspection FETCO Home Screen 1 FILLING CBS 2132 O 2012 all nghis reserved O Ready Touch O Heating screen B Ailing do unlock FETCO Home Screen 2 HEATING CBS 2132 D 20102 all ved Ready Tank T F o nos 192 FETCO Home Screen 3 READY CBS 2132 FREIEN 7 2012 all nghis reserved B Ready Touch Healing Filing to unlock Features of your FETCO Brewer Touch screen for brewer operation Brew basket sensor not accessible SD card interface port Load amp Save Hot Water Faucet Locator removable for service access Locator for airpot dispenser Two for CBS 2132 Main power switch Slide out back panel for service access Accessing batch and programming menu screens Accessing batch and programming menu screens DC voltage calibration for pumps is running First message on touchscreen display at powerup This shows Please wait only at POWER ON when ON OFF The software is analyzing and correcting any variations as a quality control feature C
27. l of water The heating process will start automatically when the tank has filled 3 Most CBS 2131 equipment is factory equipped with a 120 V cord and plug Some CBS 2131 and all CBS 2132 have a terminal block for connecting the incoming power wires Consult local codes to determine if a cord and plug can be installed on factory supplied terminal block equipment or if the unit must be hard wired 4 Plug in unit if the equipment has an attached cord amp plug or wire into circuit for terminal block units Note that the plug is NEMA 5 15P or NEMA 5 20P domestic 5 A fused disconnect switch or circuit breaker on the incoming power line must be conveniently located near the brewer and its location and markings known to the operators 6 The body of the brewer must be grounded to a suitable building ground A ground lug is provided in the brewer next to the power terminal block Use 10 gauge copper wire for grounding 7 Electrical connections must be secured in place within the unit to meet national and local standards Warning To prevent electrical shock this unit must be properly grounded WARNING DANGER Do not plug in or electrically energize this equipment or attempt operation without all covers in place and all screws fastened Electrical Configurations Terminal Block Diagram US amp Canada CBS 2131 some CBS 2131 and all CBS 2132 120 volt models 208 240 volt models Factory Configuration Attached cord 120
28. ll down to Reset 7 Follow directions shown on screen Toggling ON OFF switch Brewbasket must will not clear error codes Insert brewbasket be in place Error codes must be cleared Designs materials specifications physical dimensions firmware and software protocol for equipment or replacement parts are subject to review and change by FETCO without notice Airpot use instructions and cleaning Dispenser Diagram 0041 3 liter and DRIVEN TO INNOVATION 0063 1 gallon Airpot DESCRIPTION Dispenser Diagram The FETCO 0041 3 liter and 0063 1 gallon airpots are lever type air pressure evacuated beverage dispenser featuring double wall vacuum insulated construction The hermetically sealed vacuum double wall construction provides excellent heat or cold retention while the stainless steel outer and inner liners provide robust durability PARIS Locking Tab Lever Bellow Cap Bellow Bellow Cap Plate opout Tube Drip Through Down Tube Lip Release Button Ww Dispenser Operation Instructions FETCO 0041 3 liter and DRIVEN TO INNOVATION D063 1 gallon Airpot To Fill 1 oet brewer to dispense the Squeeze the Lid Release 3 Place the airpot under the proper amount into the Buttons to release the lid brewer against the airpot dispenser Locator if 3 liters FETCO D041 Swing the lid completely featured Or backwards Alig
29. low rate TEST Operates fill valve Fill Valve e Fill Valve Test Press to test Press To Test Have container under both brewbaskets TEST Heater Test Press to test Press To Test Energizes Heater s Use for servicing 2555 e S Brightness Brightness 1 10 Bypass option is only on 1 gallon version How to calculate flow rate Measured gt 2 90 Set Point gt 3 00 If flow rate setting is 0 49 Then new flow rate is 0 49 X 0 9620 47 By entering the new flow rate number into the brewer the software will correct the discrepancy in the pump Hot water convenience tap 1 The CBS 2130 coffee brewers include a hot water convenience tap for single cup beverage purposes 2 Single use delivery volume should not exceed maximum 16fl oz 473cc 3 Water dispensed from this faucet is very hot up to 205 F 96 C Adjustable spray pattern This FETCO equipment features digitally adjustable spray patterns for perfect penetration FETCO CBS 2131 and CBS 2132 coffee brewers feature digitally adjustable spray patterns for perfect penetration All batches can be set for wide middle or narrow spray patterns of the hot brew water that showers the coffee bed in the brewbasket The turbulence created by the spray pattern combined with variable pulses is infinitely adjustable for desired flavor extraction of individual roasts and grinds of any coffee variety The default
30. n airpot version Configuratio Heater Electrical Maximum Gallon Hour n Code Configuration 00 6 Connection Amp Draw 1 gallon per batch E213102 1 X 2 3 kW 100 120 NEMA 5 20P 16 5 19 7 5 8 gal 22 lit E213112 1X2 3 kW 100 120 NEMA 5 20P 16 5 19 7 5 8 gal 22 lit E213106 1 X 2 3 kW 200 240 Cord No Plug 8 5 10 1 5 8 gal 22 lit E213116 1X2 3 kW 200 240 Cord No Plug 8 5 10 1 5 8 gal 22 lit E213108 1X3 0 kW 200 240 Cord No Plug 10 9 13 0 7 7 gal 29 1 lit E213118 1X3 0 kW 200 240 Cord No Plug 10 9 13 0 7 7 gal 29 1 lit Electrical Configurations CBS 2132 1 gallon airpot version Configuration Heater Electrical Maximum Gallon Hour Code Configuration Bypass Voltage Connection Amp Draw 1 gallon per batch E213203 2X3 0 kW 200 240 Terminal Block 21 3 25 5 14 0 gal 53 lit E213213 2X3 0 kW 200 240 Terminal Block 21 3 25 5 14 0 gal 53 lit Designs materials specifications physical dimensions firmware and software protocol for equipment or replacement parts are subject to review and change by FETCO without notice Dimensions amp Utility Connections Rough in drawings 20 11 32 51 6 DRAIN ON OFF CBS 2131 04 3 liter 1 5 16 3 41 WATER SUPPLY INLET 9 7 1716 12 131 Rough in CBS 2131 Single station 3 liter airpot version CBS 2132 3 liter 2 7 NEMA PLUG CONFIGURATION Oc 1 NEMA 5 15P 5 20P CB
31. n prewet CBS 2131 CBS 2132 gt Regular m 1 50 9 0 F 20 Brewing CBS 2131 CBS 2132 gt Regular Brewing CBS 2131 CBS 2132 gt Regular 7 Brew completed in drip delay CBS 2131 CBS 2132 gt CBS 2132 FETCO 2012 all rights d Ready L1 Heating O Filling Reqular Regular 1 7 Decal 1 11 Note there are three BREW TEMPERATURE DEFINITONS The Brew at temperature default routine is shown below Brew basket sensor Regular enabled Unit is brewable only when F 205 brebasket is in place option may be disabled by user Brew at tempertaure enabled brew will start when tank temperature reaches he set point Both sides of CBS 2132 brewing simaltanously Both sides of CBS 2132 brewing simaltanously Both sides of CBS 2132 brewing simaltanously Left side completing drip delay CBS 2132 right side completing drip delay left side ready for next brew Decal Programming operator access programming The FETCO CBS 2130 brewers have four brew batch menus per side They are preprogrammed with basic settings that will operate the equipment as purchased There are two batches each marked Regular and two marked Decaf Most operators prefer a full batch and half batch setting for regular and decaf or specialty coffees These will need to be programmed by the operator Settin
32. n the center of the 1gallon FETCO D063 airpot Drip Through with the outlet of the brewbasket To Dispense 3 Push the lever downwards 1 After the brew cycle is completed Lever Lock drops into multiple times to dispense Remove the from position and engages the the desired amount under the brewbasket and pump mechanism close the lid Dispenser Cleaning amp Maintenance 0041 3 liter and FETCO DRIVEN TO INNOVATION D063 1 gallon Airpot DRIVEN TO INNOVATION To Clean Squeeze the Lid Release Buttons to release the lid Press the Lid Detach Button that will completely detach the lid Remove the Lid Cover Remove the Drip Through 3 Carefully remove the Detach the Down Tube and the Spout Tube Clean with warm water detergent and a brush Proprietary airpot cleaners may also be used 4 Clean the interior of the tank 5 Clean the exterior of the with warm water detergent and a brush Proprietary airpot cleaners may also be used Do not put the airpot into an automatic dishwasher Do not allow solutions containing chlorine to unit with warm water non abrasive mild detergent Do not submerge the unit in water 20 bellows Cap Handling the parts gently clean the Bellows Bellows Cap and Bellow Cap Plate with warm water and non abrasive mild detergent Do not use petroleum based or organic cleaners on food
33. nnecting it to the brewer to prevent debris from contaminating the machine Verify that the water line will provide a flow rate of at least 172gpm 5 7lpm per minute and water pressure is between 20 75 psig 138 517kPa before making any connections Install a backflow prevention device if required Many municipalities require a recognized backflow preventer Usable on all hot beverage and cold beverage equipment is a WATTS SD 2 or SD 3 These spring loaded double check valve models are accepted by most zoning authorities The check valve should be as close to the water supply inlet of the beverage equipment as possible General Utilize only qualified beverage equipment service technicians for installation A Service Company Directory is available at www fetco com Utility slide on back of brewer Power Switch Electrical Connection WARNING Leveling legs if installed are to be adjusted for leveling the brewer only Do not use for height adjustment or extend them higher than necessary Connection Installation Instructions Brewer Setup 1 Review the dimensions for the unit and verify that it will fit properly in the space intended for it Verify that the counter or table will support the total weight of the brewer and dispensers when filled specifics page 3 Place the brewer on the counter or stand When the brewer is in position level it front to back as well as side to side by adju
34. ry set Programming Range INPUTS Items Default display Brew Basket Sensor High Liquid Level probe e Input High Tank Temperature Probe Display Inputs Summery Lower Tank Temperature Probe SD Card Recognized USB Drive Recognized USB is for factory setup only Calibrate If Yes Cal Touch Scr Calibrate D Follow directions on YES NO the touch screen Chart to correct for boiling point for altitude BREW AT TEMPERATURE DEFINITONS in tank water temperature Suggested Boilin BREW AT TEMP AUTO Altitude ft 9 a Setting F point F DEFAULT FACTORY PROGRAMMED INTO BREWER 212 0 This allows the BREW START to active If the hot water 2114 tank is at the selected temperature the brew will start If the temperature is too low the brewer will wait until the 2102 proper temperature is reached A screen example to the 208 4 right will display showing a thermometer icon and the tank 207 5 temperature 206 6 IMPORTANT ALWAYS have dispenser s under the brew baskets when in the BREW TEMP mode 204 8 BREW AT TEMP ON USER SELECTABLE 205 BREW START Batch Section Buttons will not be accessible until tank temperature is at set point 203 0 The BREW START screens with the Batch Section 202 0 Buttons become accessible when hot water tank is at the 201 819 201 selected temperature The screen at right displays when m 202 the BREW AT TEMP is selected 199 3 198 3
35. sting the legs For 200 240 volt units remove the lower utility slide out at the back of the equipment to access the CON electrical connections The utility slide must remain close to the unit Note it cannot be detached completely Water Connection 1 Water inlet is a 74 inch male flare fitting 2 The brewer can be connected to a cold or hot water line Cold water is preferred for best coffee flavor but hot water will allow for faster recovery times High temperature water should not exceed 160 F 71 C 3 Install a water shut off valve near the brewer to facilitate service An in line water filter should be used it should be installed after the water shut off valve and in a position to facilitate filter replacement 4 Flush the water supply line and filter before connecting it to the brewer 5 Verify that the water line will provide at least 172gpm 5 7lpm per minute for the CBS 2131 amp CBS 2132 and also that the water pressure is between 20 75 psig 138 517kPa before connecting it to the brewer Electrical Connection US amp Canada 1 Verify that the actual voltage at the electrical service connection is compatible with the specifications on the brewer s serial number label Install an electrical ground wire 2 The temperature and water tank fill level are pre set at the factory There is no need to turn off the heaters during the installation process The heaters are disabled by the control board until the tank is ful
36. the batch selection menu A long duration TAP with fingertip Touch a top batch key for REGULAR 1 Touch batch pennant with fingertip Brewer will brew and display the icon for the function step it is in may be toggled for information On dual side brewer touch other side to access batches for brewing Right to left side switching by touch Batch will complete brewing in 5 gt minutes Brew time 4 minutes 172 min drip out Touch the Ready screen anywhere briefly to activate Touch and hold finger on selection pennant for about two h seconds to start brew Regular 2 3 50 V 7 O 5 30 Decaf 1 3 50 CBS 2132 2 FETCO 12 DRIVEN INNOVATION 2012 all rights reserved CBS 2132 selection for brewing on right Ready Touch 0852132 O Heating screen to unlock O Filling Touch batch pennant to access menu 10 Brewing shown by touchscreen Brewer screens displayed for brewing KRK CBS 2131 CBS 2132 NOTES CBS 2131 FETCO 2012 all rights d READY SCREEN Tap screen to display menus Ready Touch O Heating screen Filling unlock Unit displays four preprogrammed batch buttons per side CBS 2132 has right and left CBS 2131 CBS 2132 gt Select and hold one button for 2 seconds Regular Brew started 2 i
37. tup Cascading Spray Dome no holes to clog in sprayhead Magnetic flux brew basket sensor Four fully programmable batch sizes per side Dispenser locator under brew basket Batch sizing Brew at temperature protection Customizable batch name Brew mechanism is digitally adjustable Recipe copy Adjustable bypass with bypass option Screen logo customizable by user from SD card Three adjustable spray patterns SD card firmware program and upgrade installation Totalizing counters for brewer functions User programs save to and load from SD cards Shipped ready to operate out of the box Specifications Requirements Water Requirements CBS 2131 20 75 psig 138 517kPa 175gpm 5 7lpm Inlet Water Temperature Cold or Hot supply Coffee Filter Size CBS 2132 20 75 psig 138 517kPa 1 9 5 7 13 X5 standard FE TCO F002 Water inlet fitting is a 1 4 inch male flare Electrical See electrical configuration chart Brew Volume Temperature Full Batch liter CBS 2132 8 CBS 2131 3 liter version 200 F 93 inside water tank at sea level Full Batch 1gal CBS 2132 amp CBS 2131 1 gal version 195 F 91 x 5 at sprayhead Designs materials specifications physical dimensions firmware and software protocol for equipment or replacement parts are subject to change by FETCO without notice 2 Weights Capacities and Measurements Weights and Capacities amp Measurements 3 liter an