INSTALLATION MANUAL

image

Contents

1. LOW MED AUTO 11 LOCK display 12 SWING display 13 SLEEP display 14 Operation mode display Operation mode AUTO COOL ory FAN HEAT Remote controller F 61 15 Signal sending display 16 POWER SOFT display 17 TEMP display 18 TIMER OFF display 19 CLOCK display 20 TEMP button 21 FAN SPEED button 22 SWING button 23 HEALTH AIRFLOW button 24 POWER SOFT button 25 SET button 26 LOCK button If pressed the other buttons willbe disabled Press it once again lock will be cancelled 27 RESET button When the remote controller appears abnormal use a sharp pointed article to press this button to reset the remote controller normal NOTE Cooling only unit do not have displays and functions related with heating If the unit which you purchased has healthy function follow it If not please ignore POWER SOFT button is not available for 07k O9k 12k C Loading of the battery 1 Remove the battery cover 2 Load the batteries as illustrated 2 R 03 batteries resetting key cylinder oN 3Be sure that the loading is in line with the 4 Load the battery then put on the cover again Note The distance between the signal transmission head and the receiver hole should be within 7m without any obstacle as well When electronic started type fluorescent lamp or change over wireless telephone is installed in the type fluorescent lamp or room the receiver i
2. USER S MANUAL ial YORK BY JOHNSON CONTROLS Mini Split Air Conditioner YJHMXHOO7BARX FX 024BARX FX Contents PARTS AND FUNCTIONS 1 OPERATION 24 MAINTENANCE 4 CAUTIONS 5 6 TROUBLE SHOOTING 6 Read this manual before installation and operation Make sure that it is well kept for later reference Johnson H Controls Inlet grille Outlet Anion generator inside Horizontal flap adjust up and down air flow Parts and Functions E indoor Unit Inlet Air Purifying Filter One Oarra ee rT PE T f Se la A Emergency Switch Vertical blade adjust left and right air flow Display board Don t adjust it manually Q an Display board We 7S Q e Remote signal receiver A beeping sound is generated when a signal from remote controller isreceived Power indicator Lights up when unit starts Timer mode indicator Lights up whenTimer operation is selected 4 Operation mode indicator lights up when the compressor is on 5 Ambient temp display When receiving the remote control signal display the set temperature Actual inlet grille may vary from the one shown in the D manual according to the product purchased E Outdoor Unit C OUTLET INLET N ii fi CAE TCT iN HI N pi CAA l fn DRAIN HOSE Please be subject to t
3. 2 Press the button of healthy airflow again appears on the display Downward airflow sending Avoid the airflow blows direct to the body 3 The cancel of the healthy airflow function Press the button of healthy airflow again the unit goes on working under the condition before the setting of healthy airflow function Notice Do not direct the flap by hand Otherwise the grille will run incorrectly If the grille is not run correctly stop for a minute and then start adjusting by remote controller Note 1 After setting the healthy airflow function the position grill is fixed 2 In heating it is better to select the mode 3 In cooling it is better to select the mode 4 In cooling and dry using the air conditioner for a long time under the high air humidity condensate water may occur at the grille Operation E Timer On Off On Off Operation Set clock correctly before starting TIMER operation 1 After unit starts select your desired operation mode 2 Press TIMER button to change TIMER mode Every time the button is pressed display changes as follows Remote pues 3 H me 00 mee a TIMER OFF Then select your desired TIMER mode TIMER ON or TIMER OFF or TIMER ON OFF or aa will flash 3 Press TIME TIME button to set time It can be adjusted within 24 hours 4 After setting correct time press SET button to confirm or fa on the remote controller stops flashing 5 Cancel TIMER mode Just pre
4. EMENT ENFORCEMENT PROHIBITION Do not use power supply Take care not to damage Do not insert objects into the air cord in a bundle the power supply cord inlet or outlet O 5 2 O ZAAN PROHIBITION Do not start or stop the Do not channel the air flow directly Do not try to repair or operation by disconnecting at people especially at infants or the power supply cord the aged and so on WU Do not operate the switch with food art work precise equipment when gas appliance is running at the wet hand breeding or cultivation same time J C S Aa ae rr em fla STRICT er PROHIBITION ENFORCEMENT Do not install the unit near a fireplace Check good condition of the Do not pour water onto the unit or other heating apparatus installation stand for cleaning a S cots PROHIBITION PROHIBITION a PROHIBITION Do not place animals or plants in Do not place any objects on or Do not place flower vase or water the direct path of the air flow climb on the unit containers on the top of the unit 3 O OQ vis PROHIBITION PROHIBITION Dann Trouble shooting Before asking for service check the following first a Phenomenon Cause or check points e When unit is stopped it won t restart immediately until 3 minutes have elapsed t
5. ature set correctly e Are there some doors or windows left open e Is there any direct sunlight through the window during the cooling operation Use curtain e Are there too much heat sources Multiple Poor cooling check Cautions a Do not obstruct or cover the ventilation grille of the air Do not put fingers or any other things into the inlet outlet and swing louver e Do not allow children to play with the air conditioner In no case should children be allowed to sit on the outdoor unit Specifications e The refrigerating circuit is leak proof The machine is adaptive in following situation 1 Applicable ambient temperature range Maximum D B W B 32 C 23 C Indoor Minimum D BIWB 21 C 15 C Cooling Maximum D B W B 43 C 26 C Outdoor a Minimum D B 18 C Maximum D B 27 C Indoor i Minimum D B 15 C Heating Maximum D B W B 24 C 18 C Outdoor ae Minimum D B W B_ 7 C 8 C Outdoor Maximum D B W B 24 C 18 C INVERTER Minimum D B 15 C 2 If the power supply cord is damaged it must be replaced by the manufacturer or its service agent or a similar qualified person 3 If the fuse of indoor unit on PC board is broken please change it with the type of T 3 15A 250V If the fuse of outdoor unit is broken change it with the type of T 25A 250V The fuse is must be replaced by the manufacturer or its service agent or a similar qualified person 4 The wiring meth
6. g position Operation WE Sleep Operation Before going to bed you can simply press the SLEEP button and unit will operate in SLEEP mode and bring you a sound sleep Use of SLEEP function After the unit starts set the operation status then press SLEEP button before which the clock must be adjusted and time being set Operation Mode 1 In COOL DRY mode 1 hours after SLEEP mode starts temp will become 1 C higher than temp setting After another 1 hours temp rises by 1 C futher The unit will run for further 6 hours then stops Temp is higher than temp setting so that room temperature won t be too low for your sleep Fa SLEEP operation starts SLEEP operation ops Approx 6hrs Temp setting Unit stop C In COOL DRY mode J 2 In HEAT mode 1 hours after SLEEP mode starts temp will become 2 C lower than temp setting After another 1 hours temp decrease by 2 futher After more another 3 hours temp rises by 1 C futher The unit will run for further 3 hours then stops Temp is lower than temp setting so that room temperature won t be too high for your sleep Temp setting Unit stop Decreases 2 C 3 hrs SLEEP SLEEP operation starts operation stops In HEAT mode J 3 In AUTO mode The unit operaters in corresponding sleep mode adapted to the automatically selected operation mode 4 In FAN mode It has no SLEEP function 5 Set the wind speed change when sleeping If
7. he actual produce purchased the above picture is just from your reference HB Clock set Press CLOCK button AM or PM flashes Press TIME or Time to set correct time Each press will increase or decrease 1min If the button is kept pressed time will change quickly After time setting is confirmed press SET AM and PM stop flashing while clock starts working HEALTH N AIRFLOW SWING SLEEP York TIME SWING gt INS ces me 2E LIGHT Lock cone RESET 3 CONNECTING PIPING AND ELECTRICAL WIRING Mi Remote controller YORK o agza 12 Hate o eal Qf EEEE miea TEMP S won ERS mmer nue frer tee 1 CODE Used to select CODE A or B which will be displayed on LCD Please select A without special explanation 2 LIGHT button Control the lightening and extinguishing of the indoor LED display board 3 TIMER button 4 CLOCK button 5 SLEEP button 6 TIME button 7 MODE button 8 ON OFF button 9 TIMER ON displa y 10 FAN SPEED display Par mer mer HI
8. ille surely NOTE The photocatalyst air purifying filter will be solarized in fixed time In normal family it will be solarized every 6 months The bacteria killing medium air purifying filter will be used e for a long time no need for replacement But in the period of using them you should remove the dust frequently by using vacuum cleaner or them lightly otherwise its performance will be affected Please keep the bacteria killing medium air purifying filter in e the cool and dry conditions avoid long time directly sunshine when you stop using it or its ability of sterilization will be reduced Cautions A WARNING Please call Sales Service Shop for the Installation Do not attempt to install the air conditioner by yourself because improper works may cause electric shock fire water leakage A WARNING When abnormality such as burnt small found Use an exclusive Check proper immediately stop the operation button and power source installation of the contact sales shop with a circuit drainage securely breaker Q STRICT STRICT ENFORCEMENT ENFORCEMENT Connect power supply cord Use the proper voltage 1 Do not use power supply cord extended to the outlet completely or connected in halfway gt 2 Do not install in the place where there is any G Q Z possibility of inflammable gas leakage around the unit D 3 Do not get the unit exposed STRICT STRICT to vapor or oil steam ENFORC
9. ntil it is released JE from the stopper and remove the filter downward 3 Clean the filter f Use a vacuum cleaner to remove dust or wash the filter with water After washing dry the filter completely in the shade 4 Attach the filter Attach the filter correctly so that the FRONT indication is facing to the front Make sure that the filter is completely fixed behind the stopper lf the right and left filters are not attached correctly that may cause defects _ 5 Close the inlet grille J Maintenance eplacement of Air Purifying Filter RS E Air purifying filter is optional part 1 Open the Inlet Grille Prop up the inlet grille by using a D small device named grille support which located in the right side of the indoor unit 2 Detach the standard air filter SE ae J Slide the knob slightly upward to release the filter then withdraw it 3 Attach Air Purifying Filter Put air purifying filter appliances into the right and left filter frames 4 Attach the standard air filter Necessary installation a ATTENTION The white side of the photocatalyst air purifying filter face outside and the black side face the unit The green side of the bacteria killing medium air purifying filter face outside and the white side face the unit 5 Close the Inlet Grille Close the Gr
10. o protect the system e When the electric plug is pulled out and reinserted the protection circuit will work for 3 minutes to protect the air conditioner The system does not restart immediately e During unit operation or at stop a swishing or gurgling noise may be heard At first 2 3 minutes after unit start this noise is more noticeable This noise is generated by refrigerant flowing in the system e During unit operation a cracking noise may be heard This noise is generated by the casing expanding or shrinking because of temperature changes e Should there be a big noise from air flow in unit operation air filter may be too dirty Noise is heard Normal Performance inspection e This is because the system circulates smells from the interior air such as the smell of furniture paint cigarettes Smells are generated Mist or steam are blown out During COOL or DRY operation indoor unit may blow out mist This is due to the sudden cooling of indoor air e In DRY mode when room temperature becomes lower than temp setting 2 C unit will run intermittently at LOW speed regardless of FAN setting In dry mode fan speed can t be changed e The circuit breaker switch is ON but not off e Is there a power failure e Is fuse blownout e Is the air filter dirty Normally it should be cleaned every 15 days e Are there any obstacles before inlet and outlet e Is temper
11. od should be in line with the local wiring standard 5 The waste battery should be disposed properly 6 This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of appliance by a person responsible for their safety 7 Children should be supervised to ensure that they do not play with the appliance 8 In order to protect the units please turn off the A C first and at least 30 seconds later cutting off the power or too many people in the room during cooling operation A k J Johnson Y Controls 2014 Johnson Controls Inc www johnsoncontrols com AHHJXHAMX 140301 Johnson Controls reserve the right to change product features withouprior notice
12. ode Air flow BELOW 23 C FAN 26 C NO_ AUTOMATIC elt is not possible to operate in dry mode Test operation Test operation switch is the same as emergency switch Use this switch in the test operation when the room temperature is below 16 C do not use it in the normal operation Continue to press the test operation switch for more than 5 seconds After you hear the Pi sound twice release your finger from the switch the cooling operation starts with the air flow speed Hi WE Air Flow Direction Adjustment 1 Status display of air flow Vertical flap Pos 1 Pos 2 Pos 3 Ss Pos 4 Pos 5 Auto swing 2 Left and right air flow adjustment manual Move the vertical blade by a knob on air conditioner to adjust left and right direction referring to Fig Remote controller can memorize each operation status When starting it next time just press ON OFF button and unit will run in previous status Cautions e When adjusting the flap by hand turn off the unit e When humidity is high condensate water might occur at air outlet if all vertical louvers are adjusted to left or right t is advisable not to keep horizontal flap at downward position for a long time in COOLor DRY mode otherwise condensate water might occur Note When restart after remote turning off the remote controller will automatically memorize the previous set swin
13. oom temperature Operation Remote Display Nor Mode Controller Board 2e Under the mode of auto operation air conditioner will p m automatically select Cool or Heat operation according AWO VW Y 2 to room temperature When FAN is set to AUTO the air conditioner automatically adjusts the fan speed CooL 3 k according to room temperature In DRY mode when room temperature becomes DRY Y J lower than temp setting 2 C unit will run intermittently at LOW speed regardless of FAN setting E Coca SS In FAN operation mode the unit will not operate in COOL or HEAT mode but only in FAN mode AUTO is FAN D not available in FAN mode And temp setting is disabled In FAN mode SLEEP operation is not available HM Emergency operation and test operation Emergency Operation e Use this operation only when the remote controller is defective or lost When the emergency operation switch is pressed the Pi sound is heard once which means the start of this operation e In this operation the system automatically selects the operation modes cooling or fan or heat according to the room temperature Operation Designated Timer mode temperature mode NO AUTOMATIC No AUTOMATIC Room temperature Air flow ABOVE 23 C COOLING 26 C BELOW 230C HEAT 23 C cooling only Operation Designated Timer n Room temperature Pode temperature m
14. s apt to be disturbed in receivingthe signals so the distance to the Indoor unit should be shorter Full display or unclear display during operation Indicates the batteries have been used up Please change batteries If the remote controller can t run normally during operation please remove the batteries and reload several minutes later Hint Remove the batteries in case unit won t be in usage for a long period If there are any display after taking out just need to press reset key Operation Mi Base Operation A aes conv CLOCK TIME SWING gt POWER TIMER TIME f LIGHT j LOCK j CODE RESET 1 Unit start Press ON OFF on the remote controller unit starts 2 Select operation mode Press MODE button For each press operation mode changes as follows Remote controller ETIKI AUTO COOL DRY FAN HEAT 3 Select temp setting Press TEMP TEMP button TEMP Every time the button is pressed temp setting increase 1 C if kept depressed it will increase rapidly TEMP Every time the button is pressed temp setting decrease 1 C if kept depressed it will decrease rapidly Select a desired temperature 4 Fan speed selection Press FAN SPEED button For each press fan speed changes as follows Remote controller peat eat atl ttt LOW MED HI AUTO Air conditioner is running under displayed fan speed When FAN is set to AUTO the air conditioner automatically adjusts the fan speed according to r
15. ss TIMER button several times until TIMER mode disappears Hints After replacing batteries or a power failure happens time setting should be reset Remote controller possesses memory function when use TIMER mode next time just press SET button after mode selecting if time setting is the same as previous one According to the Time setting sequence of TIMER ON or TIMER OFF either Start Stop or Stop Start can be achieved TIMER ON OFF For Smart Use of The Air Conditioner Do not block the air inlet A or outlet y gp or a long time turn off the power supply main switch L B OFF Ba Use the timer effectively Setting of proper room temperature Remote Controller Wipe the air conditioner by using a soft and dry cloth For serious stains use a neutral detergent diluted with water Wring the water Do not use water wipe the controller with a dry cloth Do not use glass cleaner or chemical out of the cloth before wiping then wipe off cloth the detergent completely e Do not use the following for cleaning D MD Hot water over 40 C 104 F may cause Gasoline benzine thinner or cleanser may A A discoloring or deformation al damage the coating of the unit Air Filter cleaning 1 Open the inlet grille by pulling it upward 2 Remove the filter keem Push up the filter s center tab slightly u
16. the wind speed is high or middle before setting for the sleep set for lowing the wind speed after sleeping If it is low wind no change Note When TIMER function is set the sleeping function can t be set up After the sleeping function is set up if user resets TIMER function the sleeping function will be cancelled the machine will be in the state of timing on HM POWER SOFT Operation 1 POWER Operation When you need rapid heating or cooling you can use this function In COOL mode fan speed automatically takes high speed of AUTO fan mode In HEAT mode fan speed automatically takes medial speed of AUTO fan mode 2 SOFT Operation You can use this function when silence is needed for rest or reading In SOFT operation mode fan speed automatically takes low speed of AUTO fan mode Note During POWER operation in rapid HEAT or COOL mode the room will show inhomogeneous temperature distribution Long period SOFT operation will cause effect of not too cool or not too warm To cancel POWER or SOFT operation Press POWER SOFT button again POWER or SOFT disappears NOTE Cooling only unit do not have displays and functions related with heating W Healthy airflow Operation 1 Press ON OFF to starting Setting the comf ort work conditions 2 The setting of healthy airflow function 1 Press the button of healthy airflow appears on the display Horizontal airflow sending Avoid the airflow blows direct to the body