PREVENT A DISASTER FOR YOUR KOI POND User Manual Main
Contents
1. module acp Measurements No measured values are available for this module Atter approximately 24 hours the internet connection is made the graphic are ready to show 5 1 5 2 5 3 E MODULE ENTRY showroom pond Wu m temperature measurement temperature measurement 1 week Actual Last acta vale 31 temperature AE 305 5 4 n 29 7 degrees Celsius 29 5 29 28 5 5 5 Te 28 y axis top value 5 6 27 5 y axis bottom value APPLY 2 26 5 67 gt es 16 00 16 00 16 16 00 1600 10 00 1600 16 00 Sat Sun T Wed Tha F S Sicreenas vut EI ve i 5 8 5 9 ae 5 10 fig5 Measurements 27 5 1 Name of the Koiguard module to select 5 2 Name of the sensor or device to show 5 3 Shows the last time an update of the module is made This is a tool to check if there is still an internet connection with the module 5 4 Show the last updated actual measurement of the selected sensor of device 5 5 To change the limits of the graphic for manual scaling the Y axis top after change press APPLY 5 6 To change the limits of the graphic for manual scaling the Y axis bottom after change press APPLY 5 7 To download all the raw data stored at the Koiguard internet server A csv file is generated and can be showed and edit with Microsoft Excel 5 8 If set a screensaver will start after the elapsed time Pushing the Start Now button will start the screensaver immediately 5 9 With the button
2. KoiGuard PREVENT A DISASTER FOR YOUR KOI POND n wus User Manual Main Controller KOIGUARD KG MC100 MAIN CONTROLLER Important Please read This User Manual is an integral part of your purchase and use of this product It contains important instructions regarding the start up and use of the KoiGuard pond monitoring system Read this user manual carefully The product s guarantee is no longer valid should the product become damaged as a result of the failure to observe these operating instructions We do not assume any liability for any resulting damage Nor do we assume liability for damage to property or personal injury caused by the improper use or failure to observe the safety instructions for the product Improper use or failure to follow instructions will invalidate the product guarantee A KoiGuard PREVENT A DISASTER FOR YOUR KOI POND Index Page number 1 Recommended use 4 2 Components included 4 3 Technical specifications and features 4 4 Safety instructions 5 5 Installation 5 fig 1 removing the flatcable connector 5 fig 2 external connections 6 fig 3 internal connections 7 5 2 Starting up for the first time 8 6 Device buttons 9 fig 4 front keyboard 9 6 1 Functions of the device buttons 9 6 2 Explanation of the display 10 7 MENU structure 11 7 1 Measurement menu 11 7 2 Alarm menu 12 7 2 Alarm Water Quality 12 7 2 2 Alarm Temperature 13 7 2 3 Alarm Water level 14 7 2 4 Alarm rep
3. in or decreasing the value with 10 each 20 7 5 3 1 Server IP address It is possible to change the IP address of which the module will contact The current WAN IP address is shown on the screen and can be edit manual if needed The IP address is divided into 4 positions Each position can be edit by selecting the position and to change the value with lt gt or lt gt There is an option to do the in or decreasing by each step 1 or 10 The adjustments are changing real time on the screen 7 5 3 2 Standard server IP address In the memory of the Koiguard main module are default already 3 internet addresses for respectively koiguard nl koiguard com and the koiguard de server By choosing one or these addresses the module is communicating with the requested web page After selecting it with the lt ok gt button the change is made automatically 7 5 3 3 LAN IP address Software version of the module and the webserver will appear automatically when connection and validation by the Koiguard internet server is made MAC address will appear automatically Default the Koiguard main controller is set IP via DHCP Via DHCP the module will obtain an IP address automatically Only for those situations wherewith this is not preferred the LAN IP address can filled in manual 7 5 3 4 Fixed IP address Al positions van be edit by lt gt or lt gt 21 If more than one Koiguard system is connected to the sa
4. remove stronger filthiness the cloth can be moistened with lukewarm water Under no circumstances should aggressive detergents or chemical solvents be used because these could damage the surface of the casing and the letterings After cleaning make sure the control module is completely dry before plugging the device back in the socket 12 Removal Remove the no longer to be used device according to the applicable statutory regulations 23 13 Declaration of Conformity DOC DECLARATION OF CONFORMITY R amp TTED 99 5 EEC EMC directive 89 336 EEC 0700 Koiguard Report number O6CO0765RPTO1 Licence Holder Koiguard BV Address De Hoek 42 NL 1601MR Enkhuizen The Netherlands We declare on our own responsibility that the product Kind of product KoiGuard KG MC100 Is in compliance with the following norm s and documents EN 50081 1 1992 EN 50082 1 1997 EN 61000 3 3 1995 A1 2001 EN 61000 6 3 2001 A11 2004 EN 61000 3 2 2000 EN 61000 6 2 2001 Enkhuizen 16 september 2006 Manufacturer Authorised representative M G B Stroet Managing Director 34
5. C lamp 230VAC clamping terminal PUMP 230V used for the main water pump Alarm voltage free contact NO COM NC voltage free contact for the heating thermostat clamping terminal 2 float switches GND INT IN2 clamping terminal IN RS 485 KoiGuard for module communication clamping terminal OUT RS 485 KoiGuard for module communication when using clamping terminal IN 3 13 there is no connection for 12 Volt This is only available on clamping terminal OUT 3 1 4 The 12Volt is not used for communication between modules only for special sensors Please also note The wiring must be secured properly outside the enclosure for example using solid mounted wiring ducts When other external equipment is to be connected to the main controller make sure that the mains is disconnected from the total system The alarm voltage free contact 3 10 is used by the controller to switch on an external alarm device when necessary The alarm contact can switch on a lamp or high output sounder To enable the main controller to communicate with the other KoiGuard modules the required 4 cores communication wire must be installed on the clamping terminal RS 485 3 13 or 3 14 This communication wire is available in several lengths It is possible to connect 2 communication wires on each module For example when the system contains 3 modules the first cable is fitted to the main controller onto the OUT position 3 14 From the controller to the IN
6. CODE ary E MAIL for alerts c Fill out your e mail address here necessary to be able to receive the login code TELEPHONE MR MOBILE NR for alerts in format 31612345678 FAX NR 23 Step 5 An e mail is sent to the e mail address filled out earlier In this e mail you ll find an internet link Copy this link in the address bar of your internet browser or double click on the link It may take a couple of minutes before this e mail is received ind enm Thank you for registering an activation e mail has been sent to the e mail address you entered This will contain a link that you need to copy into the address line of your browser to activate your account Step 6 When the e mail has been received the registration has been successful and you can log in as user Step 7 Log in ve MENENHENEHEEEEENI Password is Enter your unique password Select Sign in Enter at User ID your personal username 9 Using MyKoiGuard To add your koiguard system to your MyKoiGuard environment please go to th ED Module oo NIEM nfiguration page module No measured values are available for this module 24 9 1 Add a module or a camera id ADD MODULE Module ID Activation code li corr Monue Select module Name E Apo camera Name Type Attached to module IP B camera Cameras Name Type Attached to module IP Port e ou um udi SCREENSAVER Activated Timer Te
7. In the Settings Menu all settings can be edit or adjusted for all sensors system and the internet The Koiguard system is default set to the Koiguard basic system 7 5 1 1 Settings sensor _ installed When a sensor is not installed the sensor shows on the measurements screen only and no values It is also possible to switch the sensor off when the shown values are no longer valid when the sensor reaches the end of its lifetime 7 5 1 2 Settings sensor _ calibration Adjust the water level till the correct value is displayed 18 De NH3 sensor which Koiguard is using only has to be calibrated the first time of use The Analogue display will show its true value The status display will show safe alert alarm or Toxic Take the new ammonium alert sensor out of its enclosure and place it into the sensor holder This procedure is completely explained in the manual of the ammonium sensor For all other explanation for the sensor calibration procedure please reed chapter 7 of the Sensor controller manual 7 5 1 3 Sensor settings _ settings When Auto disable is selected M the sensor will automatically been removed from the list when it s not installed This means that the list of sensors is only showing the installed sensors 7 5 2 Settings system All one time settings that have to be entered can be entered in the system settings 7 5 2 1 Language The control module has already been preset in sever
8. controller housing in the desired installation location The openings plastic cable glands must face downward towards the ground fig 1 You will find several screw able clamping terminals on the circuit board in the main controller s casing The installation cables are attached to these Please note The power supply connection in the main controller 2 4 only serves as the power supply for the main controller When in operation hazardous voltage is present on the circuit board 2 1 2 2 2 3 2 4 2 5 2 1 2 2 2 5 Fig 2 external connections Integral SD flash card holder Ethernet 1OBase T RJ 45 connection Cable lead through M16 for other pond equipment 230V 50Hz Cable lead through M16 for mains 230V 50Hz Cable lead through M12 for 5 12 VDC external communication 3 2 3 3 3 1 3 2 3 3 3 4 3 5 3 6 3 7 3 8 3 9 3 10 3 11 3 12 3 13 3 14 NOTE g f m Rill f f 3 4 35 3 3 7 38 3 9 3 10 3 11 3 12 3 13 3 14 Fig3 internal connections Flat cable connector Fuse 6 3A slow for external equipment Fuse 160mA slow for internal equipment 230VAC clamping terminal mains 230VAC clamping terminal VALVE1 230V used for the ozone generator 230VAC clamping terminal VALVE2 230V used for the fresh water valve 230VAC clamping terminal AIR AUX 230V used for the air pump 230VAC clamping terminal UVLAMP 230V used for the UV
9. length of the start pulse is a setting which has to be made at the module itself but can be modified from 1 120 seconds see chapter 7 4 32 10 Preservation This product is exclusively meant to be used indoors or in outdoor spaces covered from rain Do not use the product immediately after bringing it from a cold into a warm space The water from condensation can destroy the device under certain circumstances Take some time to allow the device to assume the temperature of the environment before using it This can possibly take several hours The switch socket and the plug of the device to be connected must never be touched with moist or wet hands Please make sure that the insulation of the entire product is not damaged or destroyed Check the product for damages each time before it is used If the product is damaged it is NOT allowed to connect it on mains voltage Highly dangerous If the product will not be used for a prolonged period of time it must be disconnect from mains voltage Avoid unfavorable environmental conditions during transport and on the location of use Wetness and an high level of atmospheric humidity extreme high or low temperatures dust or inflammable gasses fumes or solvents strong vibrations strong magnetic fields like near engines or loudspeakers 11 Maintenance and cleaning The product is free of maintenance Clean the control module with a soft clean dry and non fluffy cloth To
10. of the camera with the internet the camera must have an IP Address Only when the use of a static IP address is requested choose Not attached otherwise select the module which will be used nearby the camera This static IP address is necessary when the IP address is changing or when the network doesn t support DHCP Only when using the static IP address fill in the LAN IP of the camera For access of the camera true the internet it is necessary to fill in the port number which is set in the router for using port forwarding For more technical information about this matter we direct you to the camera s manual Edit a camera It is possible to change the settings of the camera Select the camera which must be edit by moving to the first line and choose the camera Do the changing and press SAVE When a camera must be deleted from the list select the camera which must be deleted by moving to the first line and choose the camera Then press DELETE Screensaver When the screensaver is activated after the selected period of time default 1 minute a Koiguard screen saver will appear on the computer screen The text can be edit 26 9 2 Measurements When using the Koiguard system for the first time with the internet the current measurements of the connected sensors will appear after a few minutes on the screen Before of that the measurement bar shows No measured values are available for this module ead Moie EC out
11. the menu When the underlying lines are no longer visible the cursor will remain in the same position Device button ESC ESCAPE BACK One level up in the menu structure Once you are in the home screen you can switch between the home screen and the operating screen Device button OK CONFIRM One level down in the menu structure or to confirm a setting 6 2 Explanation of the display 6 In the normal operational mode the display shows the current values of all of the sensors and current values In the MAIN MENU screen it is possible to change all of the settings for each item You must press the ESC button 7 to return to the MAIN MENU When an arrow appears at the right side of the screen pointing up it means that more information settings can be seen when the cursor is moved upwards When an arrow appears at the right side of the screen pointing down it means that more information settings can be seen when the cursor is moved downwards 10 7 MENU structure The KoiGuard system has been programmed with the next purpose in mind Measuring Managing Control The menu has been subdivided into 4 items whereby every item has its own sub items Press the ESC 7 button to return to the home screen The structure of the menu is the following With the device buttons 4 3 and 4 6 it is possible to run through the menu The arrow on the left side indicates the current selection When the opti
12. 3 13 position of the 2 d module From the OUT position of this module to the IN position of the 3rd module Green wire Please note during installation GND A White wire B Brown wire 12V Yellow wire Not connected for communication between modules Screw the cable lead through with a spanner so that the rubber washer closes off the opening Replace the flat cable connector of the green pcb on the bottom fig 3 1 Replace the casing cover properly and tighten its screws When using the main controller outdoors make sure that the cover s rubber seal fits properly in its groove and does not get pinched when you screw on the cover Check again that the cabling is correct Only now may you connect the power cord to the power supply 5 2 Starting up for the first time When the main power supply is switched on after a few seconds a message appears on the main controller screen you are asked to enter the serial number and activation code of the Koiguard once You can find this on the yellow paper supplied with the Koiguard on purchase Use the and buttons to edit the value at the blinking cursor see chapter 6 Press the OK button to go to the next position Use the arrow up down key to the next line When you entered your serial number and activation code go to Validate and press OK e When the combination is ok the next message appears on the Koiguard Main controller You must restar
13. LY needs to be selected with the lt gt switch To make the system recognize the fact that the lower electric power tariff is also valid during the weekend this can be indicated in WEEKEND This is off as default if this needs to be changed the position in this menu needs to be selected with the lt gt switch Here it is possible to indicate as from which moment in time this special power tariff is valid The clock has been set for this on start 23 00 hours and end at 7 00 hours as default This can be modified by adapting the values with the lt gt or lt gt switch Lock internet if selected it is not possible to control the system via the internet To allow other users or the dealer to change or adjust settings via the internet the main user should provide the login code and password for the MyKoiGuard part on the internet site The use of this function can be blocked by lock internet Keyboard click Each time a button is pressed a small beep is played Backlight The backlight of the green display is illuminated for approximately 3 minutes after pressing a button When the backlight is selected the display is always illuminated 7 5 3 Internet All settings and tools needed for the connection between the Koiguard Main Controller and the internet or the private network are explained in the chapter internet settings The Koiguard module will start up to obtain a new IP address The first position will be changed
14. WEBOO optional 5 pieces of clamping terminals for connection with other pond equipment User manual 3 Technical specifications and features Power supply Power consumption Breaking capacity per relay Total breaking capacity equipment Protection class Front keyboard Display Clamping terminals for other pond equipment Water pump Air pump O3 generator 7 UV C lamp Freshwater valve 2 float switches Alarm contact voltage free contact NO NC Data storage SD Flash card optional Network connection KoiGuard intranet KoiGuard Ethernet 230V 50Hz approx 20W max 500VA 230V 2A max 1450VA 230V 6 3A IP41 DIN EN60529 polycarbonate LCD illuminated 4 20 characters Electrical current monitored Electrical current monitored Max 10A 230V Max 2Gbyte KoiGuardNET 1 00 Serial RS 485 10Base T RJ45 4 Safety instructions The product s guarantee becomes invalid if the product is damaged as a result of the failure to observe these operating instructions We do not assume any liability for any resulting damage Nor do we assume liability for damage to property or personal injury caused by the improper use or failure to observe the safety instructions In such cases the product s guarantee becomes invalid For safety and licensing CE reasons any unauthorised alterations to and or modification of the product are not permitted The product i
15. al languages For the menu there is a choice of the following languages English German Dutch and French 7 5 2 2 Date time When the control module is switched on the correct time and date have to be entered Select Settings System lt OK gt It is also possible to have time and date synchronized by the Koiguard Internet Computer This is only possible if the Web server has been installed and connected to the Internet To activate this select SERVER TIME To activate this option the box must be checked and selected with the lt gt switch To make sure the control module runs synchronistic with Summer Daylight Saving s Time the box needs to be checked and selected with lt gt switch The system will now automatically adjust the time when the seasonal hours are being changed Manual setting of time and date can be done by moving the cursor with the up 4 3 or down 4 6 switch to the desired item There is a choice of respectively HOURS MINUTES DAY MONTH YEAR In every item the actual time date can be modified by adapting the values with the lt gt or lt gt switch When modifying the date the system automatically changes the name of the corresponding day The system time zone is set to GMT 1 hour CET 19 If it is possible to use a double electric power tariff this can be indicated at the NIGHT TARIFF lt OK gt This setting is activated as default if this needs to be modified the position APP
16. e When the Main controller is connected to the internet these data will appear automatically after approx 1 minute Next lines are the information of al the sensors but the last tree lines are special These last tree lines 7 1 1 User online When a user is connected via the MyKoiguard internet page to this Koiguard module the V box appears 7 1 2 Internet ok When the Koiguard module is connected to the internet and adapted by the Koiguard server the M box appears This means that the Koiguard module is communicating properly with the server 7 1 3 heater 12 0 C When an electrical heater is installed the M box appears when the heater is running due to the requested temperature of 12 0 C For more details of electrical heating see chapter 7 2 2 Control Temperature 11 7 2 ALARM MENU If an alarm report is necessary it will activate the voltage free alarm contact 3 10 When and how the alarm report is generated may be set in the alarm menu The Alarm Menu is divided as follows Report Shows how many unread alarm reports have been generated When reports have been generated the number will be displayed To read these reports the item must be selected Cancel alarm When the system has generated an alarm which is currently active it is possible to overrule the alarm The system stops for this specific disturbance to generate any further alarm reports When an alarm is generated by another problem or wa
17. emory of the Koiguard controller If new levels are requested these can be changed by the line Maximum or Minimum and then select the associated SAVE button Then will the current maximum and minimum levels change into the requested levels Note These changes can switch off major appliances nearby the pond 31 9 3 9 4 9 1 9 2 9 3 9 4 9 5 9 5 Scheduler With the use of the scheduler it is possible to let the Koiguard system control the equipment and devices using the timetable Devices like the fish feeder dispenser can be controlled automatically by the timetable or manually switched on off permanently 9 1 9 2 Timetable Fishfeeder dispenser Controis Ey scheduler Tit state Permanently off Click the bows in the table where you want this sensor to be turmed on j MON THE WED THU FRI SAT SUM Fig9 Timetable 9 Selected device changeable by clicking on the drop down menv Possibility to modify the current control option to By scheduler Permanently on Permanently off After changing the control please confirm by selecting SAVE Shows the current state of the Koiguard control Changes made with Mykoiguard can take several minutes With the left mouse button each cell can be selected A blue cell means that the corresponding action for the device is selected For example at Monday morning at 8 00 am the Fish feeder is getting a start pulse The
18. ives a more stable situation but the heating is switched on more often 7 3 2 Control treatment The system provides a function to control other treatment devices witch can be installed nearby the pond It is possible to switch the KoiGuard system to automatic after all adjustments are made 7 3 2 1 Ozone generator The 230V Ozone generator is directly connected to the main board of the KoiGuard system on position 3 5 VALVE Adjustable minimal and maximal value for the ORP level to control the ozone generator The device is switched on off by the use of a relays between the adjusted values Min and Max This value is measured by the Redox sensor 15 7 3 2 2pH regulation To regulate the level of the pH 230V peristaltic pumps can be installed and controlled by the Koiguard The pumps are connected to the DOSE controller KG DC100 Not available in the basic set Adjustable minimal and maximal value for the pH pump Adjustable minimal and maximal value for the pH pump 7 3 2 3 Water pump The 230V water pump is directly connected to the main board of the KoiGuard system on position 3 9 The pump is prevented for mal function by the measurement of the electrical current of the pump If an error appears the pump is switched off It is also possible to protect the pond for over floating by the use of a floating switch By the use of the AND or the OR function you re able to tell the system to switch the
19. me network the hostname of the modules has to be changed The hostname is the name which the module is using on the net It is not possible that modules have the same name Default the hostname is set to koiguard changing the name with the lt gt or lt gt button will give Using this hostname in the browser of your computer will give all the network information of the Koiguard system The section Expert tools info is no part of this manual 22 8 Register on the internet Before the KoiGuard control module can be connected to the internet the module needs to be registered once on the KoiGuard internet site To register the module you need to enter the MAC address of your internet GSM module as well as the unique product code that has been attached with the delivery purchase of this product After the registration has been checked and approved by the Koiguard computer the module will be activated on the internet environment Step 1 go to www koiguard com on your internet browser Step 2 If you are a registered user already go to step 7 if you are a new user go to step 3 uel MENENENENEEREENI Step 3 Select Register ENTER gt Step 4 Fill out the complete table and select wa 7 USERNAME 2 Enter your personal username here PASSWORD s Enter your unique password here PASSWORD re type Enter your password again NAMI z Enter your personal data here FAMILY NAME STREET NUMBER POSTAL
20. n this user manual Only people who are appropriately trained are permitted to carry out work on voltage carrying parts If you are not properly trained please consult a qualified electrician who is authorised to carry out such work Any incorrect work carried out on the supply voltage may lead to a fatal electric shock You endanger not only your own life but also the lives of others Before we can determine a suitable installation location we must be sure of a suitable and solid installation location no danger for immersion of the housing when the pond floods or leaks When you have found a suitable installation location proceed with the installation as follows Disconnect the main controller completely from the supply voltage all poles Open the main controller s casing by removing the four screws on the top surface of the device using a suitable screwdriver Disconnect the flat cable connector of the green pcb on the bottom Fig 3 1 Fig 1 removing the flat cable connector There is one hole in each of the device s four corners You can use a suitable pencil to mark the position of the main controller through the four holes in order to drill holes in a wall for inserting dowels for example The space between the holes is 188 x 88 mm Make sure that the drill holes or screws do not damage any cables power supply lines gas pipes or similar Life threatening danger Now use the appropriate screws dowels to attach the
21. ngs select Save In this dropdown is the number of SMS that will be purchased The payment will be made with Paypal The invoice for the purchased SMS will be placed here in a pdf format 30 9 4 Controls All settings regarding the control of the installed equipment of devices can be made on the main module itself as well as on the Mykoiguard internet page All settings and adjustments can be made via the internet There is a difference between the method of control on some devices The main difference will be that some devices only can be switched on or off while others are more controllable due to some limits Maximum Current state ozone generator Jd 8 1 Controls Of w 8 2 Current settings off 8 3 Off 21 07 2010 18 02 51 8 4 0400 mV 8 5 Current maximum 0400 Minimum 0300 mV Current minimum 0300 Fig8 Controls 8 1 The selected device 8 2 To change the current state it is possible to change the state to ON OFF AUTOMATIC If the setting is changed press SAVE 8 3 After SAVE is selected the current setting will be changed into the requested setting Now the internet server is connecting to the Koiguard module to make the changes 8 4 When the connection is made the current state will change automatically into its requested state Note this can take up to several minutes 8 5 Some devices can be controlled by adjustable levels The current maximum and minimum are the settings in the m
22. oduct names contained herein are trademarks of their respective owners All rights reserved Should you have any further questions please contact our technical services department KoiGuard De Hoek 42 1601 MR Enkhuizen The Netherlands info koiguard nl www koiguard nl RECYCLABLE PAPER 1 Recommended use This product the main controller KG MC100 is designed for the control of the KoiGuard pond system It is possible to connect other KoiGuard products sold separately to maintain the water quality and other processes in the garden pond or to control them No part of the product may be modified or adapted otherwise the guarantee warrantee as well as the licence CE will become invalid Any use other than the one described above may damage the product and can also increase the risk of short circuit fire electric shock etc The main controller is able to run on an Internet connection or a connection via the mobile telephone network Please note Using an external network such as the ones mentioned above can result in additional costs for you Problems with the Internet connection or mobile telephone network are out of our range of influence For obvious reasons we cannot accept any responsibility for damage caused by a malfunction of these networks Take careful note of all the safety instructions in this user manual 2 Components included Main Controller KoiGuard KG MC100 Internet SMS Module KG
23. onal subjects in the main menu are selected using the OK 4 8 device button the choice is confirmed In the Measurement menu fig 6 2 all actual and current measurement values and settings of the installed equipment are displayed When a sensor is installed the result of this measurement is automatically displayed in the menu The status of installed equipment or the presence of an Internet user in the MyKoiGuard Internet section is indicated by a check box O on the display If the check box is empty then the item is not in use In the alarm menu the current alarms reports are shown You are also able to set the minimum and maximum values for each sensor when an alarm must be generated You may also indicate how an alarm must be communicated for example by e mail SMS or only via the display In the menu part control all installed pond equipment can be controlled You can switch the equipment on or off manually or you can choose to perform the monitoring of this equipment fully automatically using the KoiGuard system Automatic functions such as water changes heating or controlling the pond filter can controlled via this menu The settings of the KoiGuard system for maintenance or the operating system can be selected in the Settings menu Network settings for the Internet and the calibration of the sensors are also available in this menu 7 1 Measurements MENU The first line of the measurements menu will show you the time and the dat
24. ort auxiliary devices 14 7 3 Control menu 15 7 3 1 Control temperature 15 7 3 2 Control treatment 15 7 3 2 1 Ozone generator 15 7 3 2 2 pH regulation 16 7 3 2 3 Water pump 16 7 3 3 Control Manual 17 7 4 Scheduler menu 17 7 5 Settings menu 18 7 5 1 1 Settings sensor installed 18 7 5 1 2 Settings sensor calibration 18 7 5 1 3 Settings sensor settings 19 7 5 2 Settings system 20 7 5 2 1 Language 20 7 5 2 2 Time Date settings 20 7 5 3 Internet 20 7 5 3 1 Server IP address 21 7 5 3 2 Standard server IP address 21 7 5 3 3 LAN IP address 21 7 5 3 4 Fixed IP address 21 d Register on the internet 9 Using MyKoiguard 9 1 Add a module or a camera 9 1 1 Add a module 9 1 2 Edit a module 9 1 3 Add a camera 9 14 Edit a camera 9 1 5 Screensaver 9 2 Measurements fig 5 measurements 9 3 Alarm settings fig 6 alarm settings fig 7 sms management 9 4 Controls fig 8 Controls 9 5 Scheduler fig 9 timetable 10 Preservation 11 Maintenance and cleaning 12 Removal 13 Declaration of Conformity DOC 23 24 25 25 25 26 26 26 27 27 29 29 30 31 31 32 32 33 33 34 Introduction Dear Customer Thank you for purchasing this product This product meets the requirements of both current national and European standards In order to ensure the continued fulfilment of legal requirements and safe operation of this product we kindly ask you to carefully follow the instructions in this user manual All company and pr
25. pdown menv For each individual sensor the action after an error occurs can be set Ignore Nothing happens Report only an alarm report is shown on the display and on the Mykoiguard site SMS An alarm SMS will be send to the given phone number E Mail An alarm e mail will be send to the given e mail address NOTE there is only one SMS sent when there is sufficient credit See 6 8 SMS credit The maximum allowable level of the sensor before an alarm is generated The minimum allowable level of the sensor before an alarm is generated After changing the settings please confirm with selecting SAVE Actual number of available SMS credits When selecting this line a new screen appears with option of buying SMS credits A SMS alarm message is only send if the SMS credits are not exhausted 29 7 1 7 2 7 3 7 4 7 5 7 6 7 1 SMS credits 421 7 2 Allow SMS information free gt Yes No SMS alert 9 On Off 7 3 ee res w 7 4 vs __ NM Number 25 21 25 0 85 per SMS The Tatler amber way t6 pay 7 6 ie Number Price M State Fig7 SMS management Number of actual SMS credits Option for free SMS information from the Koiguard company SMS alert on or off If switched off no SMS is send when an error occurs This can be useful during maintenance or when a sensor is giving no longer valid measurements caused by an expired lifetime After changing the setti
26. pump off if both floating Switches are activated or just one The activation of float switch 2 is ignored Float switch 2 is switched off in normal situation 16 7 3 3 Control Manual All the installed pond equipment and auxiliary devices can be controlled by the KoiGuard system or individually controlled manually This option is required when the selected equipment should be switched on or off immediately In this Menu each item can be switched to A automatically The KoiGuard systems controls the device 1 ON The device is switched on O OFF The device is switched off To switch on the dosing pumps for 10 seconds just move the arrow to the desired pump and press ok 7 4 Scheduler menu In the Scheduler Menu all the installed devices and equipment can be controlled by the scheduler which is visual on the MyKoiguard web page This is useful for devices that are time related and manual control tend to recur If selected it is running via the timetable Give one time pulse to the Fish feeder Adjustable pulse time The fish feeder can be installed via the KG DC100 or directly in the main controller on VALVET If selected it is running via the timetable Give one time pulse to the water valve Adjustable xxx values are multiplies of 15 seconds For example value 8 means 120 seconds 17 NOTE Filter clean is only available when the Nexus automation from Evolution Aqua is installed 7 5 Settings
27. rning it will create a new report Acoustic alarm When the system has generated an alarm which is currently active it will produce some noise with the internal buzzer for warning Alarm settings All possible adjustments and system settings related to the value of the sensors can be made in this submenu 7 2 1 Alarm Water Quality Minimum Maximum value for the pH alarm Adjustable using device button or 12 M Report When the adjusted minimum or maximum values are being exceeded the system will generate an alarm report when this item is selected The control alarm lamp on the front 4 2 will blink as well SMS When the SMS item is selected the KoiGuard system will send an alarm SMS to the adjusted cell phone number This number can be adjusted on the MyKoiGuard Internet section Only available if the personal amount of SMS credits is not exceeded E Mail When the e mail item is selected the KoiGuard system will send an alarm e mail to the adjusted e mail address This address can be adjusted on the MyKoiGuard Internet section We use the same adjustments for all of the other sensor values such as ORP Redox conductivity and oxygen For the NH3 sensor the maximum limits are set to the default values These are Default limits Alert max 0 05 ppm Alarm max 0 20 ppm Toxic max 0 50 ppm When the level for Alarm max 0 20 ppm must be set move the arrow with the NV or f bu
28. s Day Week Month 3Months 6 Months Year the time scale of the measurement graphic can be adjusted When the scale is out of limit the next error message appears De pagina op http www koiguard com meldt ES A No values are available in the measurement section of the selected sensor 5 10 Graphic of the measurements of the selected sensor or device The values of the graph are interpolated to generate a readable printout 28 9 3 Alarm settings All settings regarding the alarm can be made on the main module itself as well as on the Mykoiguard internet page All settings and adjustments can be made via the internet 6 1 6 2 6 3 6 4 6 1 6 2 6 3 6 4 6 5 6 6 6 7 6 8 Date fime Alert You still have 421 SMS credit _ ye 11 50 TESTMODULEYABIT PH tao high 3 636 am lt 17 05 2008 11 48 TESTMODULEYABIT PH too hich 3 635 Alert settings Parameter redaworp measurement v Action Maximum Minimum mV em 6 5 6 6 6 7 Fig6 Alarm report Alarm message with date time to which sensor it is and the reason of the alarm When selecting the DELETE button the shown alarm report will be deleted from the line and Its memory Settings for the alarm can be made for each sensor or activator Selecting the drop down menu shows all the sensors and activators available The settings are made for these sensor which is highlighted in the dro
29. s designed in accordance with protection class Voltage power may only be supplied via the public power supply 230V 50Hz This product is not a toy Devices operated via the supply voltage should be kept out of the reach of children Therefore take particular care when children are around Never dismantle the product There is danger of a fatal electric shock Do not leave packaging material lying around This may become a dangerous plaything in the hands of children The device is manufactured according to protection class IP41 The product is designed to be used indoors but can be used outdoors when protected from rain and dust The accident prevention regulations established by the Employer s Liability Insurance Association for electrical equipment and facilities must be adhered to in commercial facilities Make sure you only load the product up to the capacity indicated An overload may lead to the destruction of the device a fire or an electrical accident Do not use inadequate power cords These should be sized according to the load to be connected Handle the product with care Any blow or impact to the product or if it falls even a short distance can contribute to it becoming damaged The approved ambient temperature may not be exceeded during operation minimum of 20 C and maximum of 55 C 5 Installation Before assembling and using the device make sure you take note of all the safety and assembly instructions i
30. t the Koiguard by removing the power cord from mains and connect the power card to the mains again after approx 10 seconds e When the combination is not ok the next message appears on the Koiguard You have to wait a few minutes to enter the serial number and activation code again Keep the Koiguard switched on Notice When you try to enter more wrong activation codes the wait time will increase 6 Device buttons 4 1 4 2 4 1 4 2 4 3 4 4 4 5 4 6 4 7 4 8 4 9 4 3 4 4 4 5 4 6 4 7 4 8 Fig4 front keyboard 4 9 Control lamp ON Control lamp ALARM Device button UP Device button LEFT MINUS DECREASE Device button RIGHT PLUS INCREASE Device button DOWN Device button ESC ESCAPE BACK Device button OK CONFIRM Display window 4 20 characters 6 1 Functions of the device buttons 3 4 5 6 7 8 Device button UP Go to the top of the display in the menu When the underlying lines are no longer visible the cursor will remain in the same position Device button LEFT MINUS DECREASE Decreases the present adjusted values of the selected item When the only options are ON or OFF these settings will be changed Device button RIGHT PLUS INCREASE Increases the present adjusted values of the selected item When the only options are ON or OFF these settings will be changed Device button DOWN Go to the bottom of the display in
31. tton to the position and press OK The default value of 0 20 ppm is set automatically 7 2 2 Alarm Temperature 13 7 2 3 Alarm Water level Minimum Maximum value pond water level Adjust if the switch is open or closed during the normal situation Adjust if the switch is open or closed during the normal situation 7 2 4 Alarm report auxiliary devices Just like the water quality values of the pond it s also possible to monitor the status of the installed Auxiliary devices In the menu Alarm settings you can adjust the desired alarm report when a failure appears To detect if the water pump or the UV C lamp is working properly the electrical current is measured When the device is switched on the main voltage of 230V but if there is no electrical current the system detects failure and generates an alarm report and switches off the power of the selected device 7 3 Control menu In the Control Menu all requested values and settings can be adjust for integrated functions For example the automatic addition or flushing with freshwater It s also possible to switch the pond equipment ON or OFF manually 7 3 1 Control Temperature To heat the water of the pond the system uses a voltage free relays contact it can be used to switch on a heat exchanger or an electrical heater Note an optional power module KG POW001 is needed when more 650 Watt is connected Adjustable water temperature A hysteresis of 0 2K g
32. xt 9 1 1 Enter the MAC address see side of module Enter Code see attached UNIQUE YELLOW sheet 0004A4000035 module bd ba aE Possibility to enter a module name Koiguard CAM 001 X Not attached Choose Not attached if you want to use a static IP address lt Choose which camera to change Possibility to enter a camera name Select the model of the camera installed Koiguard CAM 001 bd Not attached Choose Not attached if you want to use a static IP c Q0 0 0 address No Yes 1 Minutes www koiguard com Add a module When using the Koiguard module for the first time or when an extra Koiguard system is installed the module must be added to the own MyKoiguard environment Please fill in on the form ADD MODULE on the item Module ID the number witch is shown on the enclosed yellow paper Next the Activation code must filled in then press SAVE 9 1 2 Edit a module The module can be provided with a name in stead of only a serial MAC number This can be very useful when using several modules Select the desired module and fill in a name then press SAVE 25 9 1 3 9 1 4 9 1 5 Add a camera To Add a camera to the Koiguard system fill in the name of the camera on the first line It is useful to have use a name for the camera if several camera s are connected After that the type model of the camera must be selected by using the right blue drop down arrow For the operation
Download Pdf Manuals
Related Search
Related Contents
TA-Nr. 021891 02/07 Änd.-Nr. 29799 User`s Manual-Royalty Rate File Maint-READ Controladores de Temperatura Microprocessados Tripp Lite Cat6 Gigabit Snagless Molded Patch Cable (RJ45 M/M) - Green, 15-ft. Qu`y a-t-il de nouveau ? 1. Nouvel emballage 2) Nouvel DOSSIER DE CANDIDATURE Mode d`emploi Arquivo 1 ORIGO 5100 【課題】新規なノッチリガンド分子の遺伝子配列 La Qualité Vorw_erk Copyright © All rights reserved.