1. Com N O Com N O NIC n2 Com N O be N C Com Com d A N C QV 12V Relay 1 Relay 2 lay 3 Relay 4 Relay 5 Relay 6 Relay 7 Relay Outputs 1 8 Aux 12V INS191 Installation Premier Relay Module Installation Manual 2 Installation General Before attempting to install the Premier RM8 relay module isolate ALL power from the control panel AC Mains and Battery Do not continue if there is power still present on the control panel DR Plugging on the Relay Module with power still present on the control panel may damage the relay module control panel or both and invalidate any warranty Plugging on the Relay Module 1 Ensure that the Relay Module is the correct way up see page 3 2 Ensure that all pins on the control panel line up the sockets on the Relay Module 3 Gently press down on the Relay Module until the relay Module is seated correctly 4 Reconnect power to the control panel Testing on the Relay Module 1 For plug on operation test the Relay Module in accordance with the control panel instructions 2 Totestthe auxiliary inputs apply OV to each input in turn and ensure that the correct LED illuminates and a click is heard from the relay 4 INS191 Premier Relay Module Installation Manual Specifications Connecting Outputs The Premier RM8 Relay Module has 8 outputs These outputs can be used to drive auxiliary devices such as LED s sounders or co
2. 2 INTRUDER ALARM MANUFACTURER L N N ER OF THE YEAR BEST MANUFACTURER 200 200081999 THANK YOU FOR VOTING TEXECOM INSTALLATION MANUAL 7 Premier Hm Relay Module www texe com Contents Premier Relay Module Installation Manual pou a MH 3 cir Al e M 4 Plugging on the Relay Module Testing on the Relay Module Connecting OUIDls iiepm pe HAHEHHHHEH EHE EHE HAE HE FEY 5 Connectinq Inputs sisse i ARAM AMAMAMAMAMAMARRARHARHRARHARHARHRRHREHREK HR RERO 5 3 Specifications Electrical Environmental Physical Standards 7 hu pn p 7 2 INS191 Premier Relay Module Installation Manual Overview General The Premier RM8 Relay Module is compatible with any control panels that have a plug on RedCARE Dualcom footprint Features 8 relay outputs 12V 3Amp each 8 Auxiliary inputs ve applied Auxiliary 12V output protected by a 1 Amp fuse Relay ON indication via LED s Relay Module PCB Layout Auxiliary Inputs 1 8 ve applied RLI RL2 RL3 RL4 ALS RL amp RL7 ALB e LC C ACC Ft Relay ON 5 A Indicators Num al a Fuse e ane sees d mammam
3. mmunicators etc Each output is a clean contact relay rated at 12V The diagram below shows typical wiring examples for the outputs Premier Rm8 Relay Module D D D gt lt gt gt gt gt gt gt vuela BEEE Cem N C Com N O Cd Relay 1 Relay 2 LED 1 0 12V Buzzer Connecting Inputs The Premier RM8 Relay Module has 8 auxiliary inputs These inputs can be used to activate the relays from an external source Each input is Ve applied and draws up to 30mA The diagram below shows typical wiring examples for the inputs Ve Outputs from external Source Outputs E 4 ALS RL6 RL7 ALB m un lt 2 Premier Rm8 Relay Module 5 0NvN INS191 Specifications Premier Relay Module Installation Manual 3 Specifications Electrical Operating Voltage Current Consumption Quiescent One Relay ON ALL Relays On Outputs O P 1 to 8 Inputs O P 1 to 8 Environmental Operating Temperature Storage Temperature Maximum Humidity EMC Environment Physical Dimensions Packed Weight 10 13 7Vpc 10mA 40mA 250mA 12V Clean Contact each ve applied each 10 C 14 F to 50 122 F 20 C 4 F to 60 C 140 F 95 non condensing Residential Commercial Light Industrial Indust
4. rial 145mm x 75mm x 30mm 100g approx INS191 Premier Relay Module Installation Manual Specifications Standards Conforms to European Union EU Electro Magnetic Compatibility EMC Directive 89 336 EEC amended by 92 31 EEC and 93 68 EEC The CE mark indicates that this product complies with the European requirements for safety health environmental and customer protection Warranty All Texecom products are designed for reliable trouble free operation Quality is carefully monitored by extensive computerised testing As a result the Premier RM8 relay module is covered by a two year warranty against defects in material or workmanship As the Premier RM8 relay module is not a complete alarm system but only a part thereof Texecom cannot accept responsibility or liability for any damages whatsoever based on a claim that the Premier 8 failed to function correctly Due to our policy of continuous improvement Texecom reserve the right to change specification without prior notice Premier is a trademark of Texecom Ltd INS191 7 www texe com Texecom Limited Bradwood Court St Crispin Way Haslingden Lancashire BB4 4PW England Technical Support Tel 44 0 1706 234833 Tel 44 0 1706 234811 Fax 44 0 1706 213187 INS191

Download Pdf Manuals

image

Related Search

Related Contents

casos, experiências e proposições  "user manual"  1. Introduction to the Personal Lines Module  Function of Gmate  Dimension One Spas Home Series User's Manual  GBC IB386619 binding cover  USER MANUAL Letter US  Untitled - Krulalltech  UV Manual Recent  Rexel Smartcut A200  

Copyright © All rights reserved.
Failed to retrieve file