Home

Installation and User Manual Advanced Battery - Tech

image

Contents

1. Find Editing charging configuration paragraph page 8 1 Ensure that the charger is unplugged and that the installation environment meets the conditions described in the previous paragraph Warning Explosive gases Prevent flames and sparks Provide adeguate ventilation during charging 2 Connect the charger cables to the battery terminals the positive cable to the positive terminal and the negative cable to the negative terminal The positive cable is red colored The negative cable is black or blue 3 Turn the power on by plugging the power cord in a mains outlet with protective earth 4 Charging starts automatically STOP Pressing STOP will PAUSE charging Pressing STOP again resumes charging F1 and F2 F1 and F2 buttons can be assigned the various functionality By default no function is assigned F1 and F2 pressed at power on Charger is configured with factory default settings The factory default setting is 12 cells algorithm LK10 06 freely ventilated capacity 50 Ah 5 Front panel indicators Error STOP button Charging F1 F1 button F1 function LED Ready ET Fa F2 button O F2 function LED Mains Radio X L Green flashing STOP pressed _ charging paused Yellow continuously lit main charging phase Defined in charging algorithm Additional charging Defined in charging algorithm Equalize charging Defined in charging algorithm Charging ready mainte
2. 1 ln fixed installation the operation temperature range is 35 C to 55 Higher than 40 ambient temperature will limit the output power Caution Mains cord amp battery cable indoor use min temperature 5 C Do not bend in cold environment 2 The charger is to be installed vertically on a concrete or other non combustible surface only For unplugging the unit make sure the wall socket is located in an easy access area 3 To ensure sufficient ventilation leave a free space of at least 10 cm around all sides and 30 cm top and bottom of the charger Do not cover the unit 4 The charging process generates explosive hydrogen gas Install the charger as far away from the battery as possible to prevent hydrogen gases from entering the charger Keep the area well ventilated Never use an open flame or equipment that produces Sparks close to the battery and charger 5 Charger is to be installed vertically to a wall like shown in the next figures BRACKET 1 BRACKET 2 Operations Read these operating instructions carefully before using the charger for the first time Also read the safety instructions in the next paragraph thoroughly It must be ensured that children do not play with the device To charge a battery with the R1100 charger follow these instructions Charger is configured with factory default settings The factory default setting is 12 cells algorithm LK10 06 freely ventilated capacity 50 Ah
3. R1100 Installation and User Manual Advanced Battery Chargers Table of POWERFINN R1100 2 contents Genea i e hook aeons 2 Installation and Warnings 3 Operations Sa retenue cernes 5 Safety Instructions 7 Troubleshooting and repalr 8 GAME sien tota on kt 8 Editing charging configuration 8 Charger dimensions 221 9 R1100 Powerfinn R1100 battery chargers use modern switching technology The intelligent microcontroller extends the life of the battery by Supervising the charging process The charger is compact silent and meets the EU safety and EMC requirements Protection class against water amp dirt is IP54 General R1100 chargers are available for a variety of battery types The charger type and charging algorithm should correspond to the battery sealed vented etc Attempting to charge a battery with the wrong type of charger may result in considerable damage Find Editing charging configuration paragraph page 8 and Operations page 5 Check the battery to ascertain that the five hour capacity in ampere hours Ah5 is between 5 and 14 times greater than the nominal current in amperes of the charger E g a 10A charger is suitable for charging batteries with a 5 hour capacity of 50Ah 140Ah Installation and Warnings The following points must be respected when choosing a location for the charger
4. nance charging Defined in charging algorithm m E E a gt lt ee E p a E E u B Alarm low battery voltage Defined in charging algorithm Alarm high battery voltage Defined in charging algorithm Alarm time limit exceeded Defined in charging algorithm Alarm Ah limit exceeded Defined in charging algorithm X Alarm invalid charging parameters s ii Alarm high charger temperature Alarm low charger temperature or sensor fault Alarm regulation fault 6 To avoid sparking disconnect the charger from the mains voltage before removing charger output cables from the battery terminals Safety Instructions In addition to the safety measures mentioned under Operations page o the following personal precautions should be taken whenever charging batteries 1 For emergency situations ensure in advance that help is available in time of need Batteries contain acid that is harmful to the eyes skin and clothes Always wear overalls and safety goggles Never touch the eyes with unwashed hands after handling batteries Ensure that a working fresh water tap is available If acid gets into the eyes or on the skin immediately rinse the area with plenty of water for several minutes If visible injury occurs contact a physician immediately In case of eye injuries always contact a physician The charging process generates explosive hydrogen gas Do not smoke or otherwise bring burni
5. ng or sparking matter to the vicinity of the battery when it is being charged If a short circuit occurs the battery may explode or the item causing the short circuit may melt Keep the work area clear from tools and debris Remove jewelry watches etcetera before working with the battery The power cord should be unplugged and the battery must be disconnected from the charger in case the equipment is left unused for a longer period of time The charger must locate away from heat sources like radiators and heat registers This device is not meant to be used by children or people whose physical sensory or mental attributes or lack of experience and knowledge prevent them from using the device safely unless a person responsible for their safety supervises them or has instructed them how to use the device Trouble If the cause of malfunction cannot be found contact your retailer or the shooting manufacturer Only authorized persons can repair the charger and repair Guarantee The charger has a guarantee of two years from the date of purchase Guarantee covers manufacturing and component failures and is valid only if the equipment is installed and used according to the instructions in this manual Keep the receipt as evidence of the date of purchase Editing Disconnect battery charging Connect charger to mains supply configuration As soon as blue LED is lit press STOP for about 10 s All LEDs should flash sh
6. ortly Release STOP 4 Special configuration mode has been entered Various charging algorithms and battery capacities can be selected The list of selections and their indications are according to the table below Charger displays table item 1 5 Press STOP to scroll down the list Small yellow LED F1 indicates if item is on or off Press F1 to toggle item on off After configuration is done disconnect charger from mains algorithm LK10 06 freely ventilated algorithm LK10 04 wet puls Sonnenschein yellow green algorithm LK10 05 wet with constant current maintenance charging nn ser Algorithms LK10 06 freely ventilated 0 3 3 0 U W cell 0 2 2 0 0 1 1 0 IE time LK10 04 wet puls 0 3 een 3 0 O A TEE S U V cell 0 2 2 0 0 1 1 0 IC time LK20 09 valve ventilated Sonnenschein 3 0 U V cell 2 0 1 0 time LK10 05 wet with constant current maintenance charging 3 0 U V cell 2 0 1 0 time 10 PP100 unsealed 3 0 U W cell 2 0 1 0 time PP101 sealed 3 0 J V cel 2 0 1 0 time 11 PP102 Sonnenschein 3 0 U V cell 2 0 1 0 time 12 Charger dimensions 289 107 229 KU KP039 doc 14