Home

Mettler Toledo Multirange Apllication software IND690

image

Contents

1. No Content Format 301 Pac version Response A B IND690 Form V1 00 302 Program number Response A B 1P62 0 0xxx 310 Counter Response A B Number 4 Comment Application FORMULATION PHARMA FORMULATION Component counter Application TOTALIZING Item counter 311 Container counter Response A B Number 4 Comment only with the application FORMULATION PHARMA FORMULATION 312 Component counter Response A B Number 4 current container Comment only with the application FORMULATION 313 Sum net weight Response A B Weight value _ Unit 314 Sum gross weight Response A B Weight value Unit Comment only with the application TOTALIZING 315 Manual entry Response A B Weight value _ Unit 316 Unit manual entry Response A B Unit Write AW 3 1 6 Unit 317 Start value item Response A B Number 4 counter Write A W 3 1 7 Number 4 Comment only with the application TOTALIZING 318 001 Identification data Response A B Name Text 20 Identification Text 20 TE Code A Code F Write A W 3 x x Name Text 20 Identification Text 20 318 006 Comment xx 18 001 18 006 corresponds to the application blocks 094 099 318 Identification data Response equal fo 318 is Code A Code D Write equal to 318 321 Comment xx 18 21 corresponds to the application blocks 094 097 322 Sum
2. 1 5 1 Ending totalizing 1 5 2 1 5 3 1 5 4 Totalizing 1 Press CODE A key and enter the identification for the sum 2 Press CODE C key and enter the identification for the first item 3 Put the first item on 4 Press PLUS key The item counter is increased by 1 and displayed with the gross sum e Place the additional items on and repeat steps 2 to 4 6 Press SUM key The gross sum is displayed and printed out automatically 7 n order to place the gross sum into temporay storage press the ENTER key 8 In order to delete the gross sum press the CLEAR key The item counter is reset Transferring the weight value to the sum Press MANUAL key 2 Enter the weight value and confirm with ENTER The weight value is stored in the sum memory and the item counter is increased by 1 Note The weight unit for entering known weight values can be selected with the lt or gt cursor key TOTALIZING on multiple weighing platforms Up to 4 weighing platforms can be connected to the IND690 Form see section Basic functions in the operating instructions IND690 Base weighing terminal Changing the weighing platform is always possible when using the TOTALIZING application Recalling information regarding the TOTALIZING application Using the key sequence INFO FUNCTION key you can recall information regarding ihe TOTALIZING application INFO MANUAL Display the last entered weight value INFO PLUS Display the
3. METTL Application software IND690 Form nn e 5 E 5 g E g IN OOOO A O6 WWW mt com support ServiceXXL Tailored Services Congratulations on choosing the quality and precision of METTLER TOLEDO Proper use according to these instructions and regular calibration and maintenance by our factory trained service team ensure dependable and accurate operation protecting your investment Contact us about a ServiceXXL agreement tailored to your needs and budget We invite you to register your product at www mt com productregistration so we can contact you about enhancements updates and important notifications concerning your product IND690 Form Contents Contents Page 1 Formulation functions eeeeeeeee enn nnn nnne 4 1 1 DocurmentatiOD i ecce rtt e E edax ruit Pe ei c REB 4 1 2 INITOGUCTION Ss odes to er e cte S o ep tb teen Cc Qt 4 1 3 FORMULATION application sesemmH 4 1 4 PHARMA FORMULATION application eene 7 1 5 TOTALIZING application rrenan 9 2 Settings in the master mode cccsseeeeeeeeeeeeeeseeneeeeeseeeeeeeneeeeess 11 2 1 Overview of the PAC master mode block 1 22 Settings in the PAC master mode block sner 11 3 Application blocks eeeee serrer enne nnn 13 4 What to do if 2 e nnn nnn nnn nnn nnn nns 15 5 Technical dali onen
4. keys Example PHARMA FORMULATION on multiple weighing platforms Up to 4 weighing platforms can be connected to the IND690 Form see section Basic functions in the operating instructions IND690 Base weighing terminal Note formulation on multiple weighing platforms gt Use a separate container on each weighing platform Recalling information regarding the PHARMA FORMULATION application Using the key sequence INFO FUNCTION key you can recall information regarding the PHARMA FORMULATION application INFO MANUAL Display the last entered weight value INFO CONTAINER Display the sum for the current container TOTALIZING application In this application you can determine the total weight of several items Each sum and each item can be provided with an identification Prerequisite In the master mode the TOTALIZING application is selected With the TOTALIZING application the function keys are allocated as follows MANUAL SUM PLUS Enter weight values manually Display gross sum and print Add weight values out gt Press the relevant function key in order to select the function Press the MANUAL key Then you can enter the weight values manually via the keyboard If the function keys have a different allocation gt Press the cursor keys lt or gt repeatedly until the function key assignment shown above appears Operating instructions 22012821A 08 08 9 Formulation functions IND690 Form
5. net sum is to be placed into temporary storage press the ENTER key Press CLEAR key The net sum is deleted and the component counter and the container counter are reset 1 3 2 Carrying over the known weight value to the sum l 2 Press MAN key Enter the weight value and confirm with ENTER The weight value is stored in the sum memory and the component counter is increased by 1 Note With the FUNCTION CHANGE key you can select the weight unit for entering known weight values Operating instructions 22012821A 08 08 5 Formulation functions IND690 Form 1 3 3 1 3 4 1 3 5 Tolerance control with DeltaTrac Using DeltaTrac in the application FILLING you can monitor on weighing in the compliance of the tolerances with the target weight see section Additional functions in the operating instructions and installation information IND690 Base weighing terminal The weight value is only added to the sum when the weight value lies within the tolerance limits 1 Preset the DeltaTrac target values for the current component 2 Add the component If there is an addition beyond the tolerance limits remove the container and fill again or delete the target value 3 Press PLUS key The components are only carried over to the sum when they lie within the tolerance limits Note The weight unit for entering the DeltaTrac target values can be selected with the cursor keys lt or gt FORMULATION on multiple weighi
6. the keyboard When the function keys have a different allocation gt Press the cursor keys lt or gt repeatedly until the function key assignment shown above appears 4 Operating instructions 22012821A 08 08 IND690 Form Formulation functions 1 3 1 Formulation l 2 3 4 Changing the container 7 Ending formulation 8 11 12 Press CODE A key and enter the identification for the recipe Place the empty container on the weighing platform and tare Press CODE C key and enter the identification for the first component Add first component The display indicates the net weight of the current component Press PLUS key The weighing platform tares automatically and the display registers 0 000 kg The current net sum in the container is determined and the component counter is increased by 1 In order to add further components in the container repeat steps 3 to 5 Max 15 components per container are possible If more than 15 components are filled into a container or the container is overfilled Press CONT key and place a new container on the weighing platform The container counter is increased by 1 the component counter is set back to zero for the new container and the tare weight is deleted When fewer than 15 components have been dispensed into container press CONT key Clear weighing platform Press SUM key The net sum is displayed and automatically printed out If the
7. g instructions IND690 Base weighing terminal The weight value is only added to the sum when the weight value lies within the tolerance limits Possible settings in the master mode e FILL A target value applicable to all fillings e COMPOUNDING A target value for each container or each component Filling 1 Preset DeltaTrac target values 2 Add component If there is an addition beyond the tolerance limits remove the container and fill again or delete the target value 3 Press CONTAINER key The components are only then carried over to the sum if they lie within the tolerance limits 4 For the additional components repeat steps 2 and 3 The DeltaTrac target values remain stored until new values are entered or the values are deleted Compounding 1 Preset the DeltaTrac target values for the components 2 Add component If there is an addition beyond the tolerance limits remove the container and fill again or delete the target value 3 Press CONTAINER key The component is only then carried over to the sum if it lies within the tolerance limits 4 For additional components repeat steps 1 fo 3 The DeltaTrac target values are deleted after each component Note The weight unit for entering the DeltaTrac target values can be selected with the cursor keys lt or gt Operating instructions 22012821A 08 08 IND690 Form Formulation functions 1 4 4 1 4 5 1 5 Function
8. ian anar PRESA RE RAE TASTE RE ORE EE ERES Raai 16 6 INdeX ss tara Sa Dia DE dona SD a dade nd 7 Operating instructions 2201282 1A 08 08 3 Formulation functions IND690 Form 1 Formulation functions 1 1 Documentation The weighing terminal IND690 comes supplied with a CD containing all the documentation on the weighing system IND690 These operating instructions describe the operation and configuration of the application software IND690 Form The basic information for working with the weighing terminal IND690 can be found in the operating instructions IND690 Base 1 2 Introduction The IND690 Form offers 3 different formulation applications which you can select in ihe master mode FORMULATION PHARMA FORMULATION and TOTALIZING FORMULATION application In this application you can measure out several components into a container one after the other Each recipe and each component can be provided with an identification Prerequisite In the master mode the FORMULATION application is selected Function keys With the FORMULATION application the function keys are allocated as follows MAN SUM CONT PLUS Enter weight Display net Subtotal for Add weight values sumand print current values manually out container gt Press the relevant function key in order to select the function Example lt gt Press the MAN key Then you can enter the known weight values manually via
9. keyboard If the function keys have a different allocation gt Press the cursor keys lt or gt repeatedly until the function key assignment shown above appears Pharma formulation 1 Press CODE A key and enter the identification for the recipe 2 Place the conatiner on the weighing platform and tare The container counter is increased by 1 3 Press CODE C key and enter the identification of the first component 4 Add the components The display shows the net weight of the current component 5 Press CONTAINER key The tare weight of the container is deleted 6 In order to add further components repeat steps 2 to 5 Press SUM key The net sum is displayed and automatically printed out 8 If the net sum is to be placed into temporary storage press the ENTER key 9 Press CLEAR key The net sum is deleted and the component and container counters are reset Formulation functions IND690 Form 1 4 2 1 4 3 Carrying over the weight values to the sum 1 Press MANUAL key 2 Enter the weight value and confirm with ENTER The weight value is stored in the sum memory and the item counter is increased by 1 Note The weight unit for entering known weight values can be selected with the cursor keys Or Tolerance control with DeltaTrac With DeltaTrac in the application FILLING you can monitor on weighing in the compliance of the tolerances with a target value see section Additional functions in the operatin
10. m or for net sum exceeded Delete sum and form sub sum OVERFLOW CONTAINER e Capacity of buffer for container counter Reset counter by deleting sum exceeded gt Suitably divide sum or recipe OVERFLOW e tem counter or component counter gt Reset counter by deleting sum ITEMCOUNTER has reached stop value gt Select suitable start and stop value OVERFLOW MAN INPUT e Manual entry would exceed capacity Check value of manual entry of sum buffer Check value of FACTOR FOR NEUTRAL UNIT WEIGHT TOO LOW e Totalizing or formulation with weight Place item on platform or fill which is too low component watch 10 d weight threshold NEGATIVE COMPONENT e Current component negative gt Place component removed last on scale again until second display is positive NO VALUE e Manual entry No value or zero entered Enter permissible value CONT NOT FINISHED e Sum key pressed without having gt Form all container sums formed container sum for all scales used beforehand CLEAR SUM e Sum not cleared Clear sum Operating instructions 22012821A 08 08 Technical data IND690 Form 9 Technical data Formulation functions Sum memory Up to 8 places including decimal point Manual entry memory Up to 6 places including decimal point Item counter Up to 9 999 with freely selectable start and stop value only for TOTALIZING application Component coun
11. net weight Response A B _ Weight value _ Unit current container Comment only with the application FORMULATION Operating instructions 22012821A 08 08 Application blocks IND690 Form No Content Format 323 Net weight Response A B Weight value _ Unit last start weight 324 Net weight Response A B Identification text 20 _ Weight value _ Unit 338 component 1 15 Comment only with the application FORMULATION 339 Tare weight Response A B Weight value Unit current container Comment only with the application FORMULATION PHARMA FORMULATION 340 Stop value item Response A B Number 4 counter Write A W 3 4 0 Number 4 Comment only with the application TOTALIZING 341 Conversion factor for Response A B Weight value _ Unit the neutral unit with Write A W 3 4 1 Weignt value __ Unit manual entry 342 Gross weight last Response A B _ Weight value Unit totalizing procedure 343 Tare weight last Response A B Weight value _ Unit totalizing procedure Write A W 3 4 3 Weight value _ Unit 14 Operating instructions 22012821A 08 08 IND690 Form What to do if a 4 Whatto do if Error Display Possible causes Remedy OVERFLOW SUM GROSS OVERFLOW SUM NET Capacity of buffer for gross su
12. ng platforms Up to 4 weighing platforms can be connected to the IND690 Form see section Basic functions in the operating instructions IND690 Base weighing terminal Note for formulation on multiple weighing platforms gt Use a separate container on each weighing platform Recalling information regarding the FORMULATION application Using the key sequence INFO FUNCTION key you can recall information regarding the FORMULATION application INFO MAN Display last entered weight value INFO CONT Display number and subtotal for the current container INFO PLUS Display the last weighed components Operating instructions 22012821A 08 08 Formulation functions IND690 Form 1 4 1 2 AR AR Function keys Example 1 4 1 Ending pharma formulation Operating instructions 22012821A 08 08 PHARMA FORMULATION application In this application you can fill each component of a recipe in a separate container Each recipe and each component can be individually provided with an identification Prerequisite In master mode the PHARMA FORMULATION application is selected With the PHARMA FORMULATION application the function keys are allocated as follows MANUAL SUM CONTAINER Enter weight value manually Display net sum and print out Close container gt Press the relevant function key in order to choose the functions Press the MANUAL key Then you can enter the known weight values manually via the
13. number of items weighed until now Operating instructions 22012821A 08 08 IND690 Form Settings in the master mode 2 Settings in the master mode 2 1 Legend 2 2 Overview of the PAC master mode block In this block the following settings are possible gea erue Tre DISPLAY DISPLAY ON DISPLAY OFF RESET PAC e Blocks on a grey background are described extensively in the following e Factory settings are printed in bold type Blocks that appear only under specific conditions are dotted Settings in the PAC master mode block APPLICATION Select application FORMULATION Fill the recipe components one after the other into the container PHARMA FORMULATION Fill the recipe components one after the other into separate containers Possible settings e FILL Fill all components to the same target value COMPOUNDING Fill each component to a different target value TOTALIZING Totalize several items Operating instructions 22012821A 08 08 11 Settings in the master mode IND690 Form ITEM COUNTER Set the item counter with the application TOTALIZING START VALUE Possible values 1 9999 factory setting 1 STOP VALUE Possible values 1 9999 factory setting 9999 UNIT MANUAL ENTRY Select preferred unit for weight values which are entered with the MANUAL key UNIT Possible units g kg Ib ozt dwt oz S
14. ter Up to 9 999 only for FORMULATION and PHARMA FORMULATION applications Container counter Up to 9 999 only for FORMULATION and PHARMA FORMULATION applications 16 Operating instructions 22012821A 08 08 IND690 Form Index 6 Index A Application 4 7 9 11 C Compounding 8 D DeltaTrac 8 E Error messages 15 F Filling 8 11 Formulation functions 4 16 Function keys 4 7 9 l Item counter 12 R Reset Pac 12 S Subtractive weighing 12 U Unit manual entry 12 Ww What to do if 15 Operating instructions 22012821A 08 08 Ne rwv Texvohoy e ABEE l paka 113 T 0 67934 l to 15344 l pakaq Tn 210 6654544 Z yion Fax 210 6654545 Zhyavon marketing nefton gr ZULLSPQWON www nefton gr 22012821A Subject fo technical changes Mettler Toledo Albstadt GmbH 08 08 Printed in Germany 22012821A Mettler Toledo Albstadt GmbH D 72458 Albstadt Tel 49 7431 14 0 Fax 49 7431 14 232 Internet http www mt com
15. tk Pcs neutral unit Factory setting kg FACTOR Enter the conversion factor for the neutral unit Example For determining the weight of liquids enter the density of the liquid as the factor In weighing operation enter the volume of the liquid the weight of the liquid is displayed DETAILED DISPLAY Switch on off additional info line in display If DETAILED DISPLAY ON is set an additional line for info appears in the display e g Item 2 9999 For FORMULATION PHARMA FORMULATION und TOTALIZING only Factory setting DETAILED DISPLAY OFF SUBTRACTIVE WEIGHING Switch on off totalizing with subtractive weighing If SUBTRACTIVE WEIGHING ON is selected totalising can also occur with subtractive weighing For the TOTALIZING application only Factory setting SUBTRACTIVE WEIGHING OFF RESET PAC Reset all functions to the factory settings APPLICATION Formulation ITEM COUNTER Start value 1 final value 9999 UNIT MANUAL ENTRY kg DETAILED DISPLAY Off SUBTRACTIVE WEIGHING Off Operating instructions 22012821A 08 08 IND690 Form Application blocks 3 Application blocks In the following description the application blocks are shown in the syntax for the MMR command set When used with the SICS command set please observe the SICS conventions see Operating instructions for IND690 Base weighing terminal