FIREBOY plus Operating instructions
Contents
1. MISSING process the contact added correctly pin onthe burnerhead Add burner head is not detected Contact pin on burner head is contaminated gt Clean the contact pin EXCESS Burner chamber Continuous operation overheated TEMPERATURE temperature the device measured exceeds gt Wait until the device has cooled the critical value off Ambient temperature exceeds the permitted value Reflection of the flame on the device due to unauthorized use FLAME Failure of Electrode of the flame monitor is DETECTION flame monitor kinked or dirty FAIL gt Visually inspect if necessary clean TECHNICAL gt Note number NN and call ERROR NN service technician www integra biosciences com 21 English FIREBOY plus Operating instructions V04 Maintenance 5 Maintenance 5 1 Cleaning and servicing A FIREBOY plus body and burner head should be regularly cleaned in order to maintain a high availability Maintenance intervals depend on operating conditions and degree of pollution WARNING Allow the burner head to cool off before cleaning disinfecting and servicing the device Switch off the device and disconnect it from the gas supply Allow the device to dry before operating it again Use a cloth moistened with soapy water or a 70 ethanol solution to clean FIREBOY plus Longest life span of burner head is reached with a splash free application in a clean working environment see also 4 7 Working with liquids on p
2. Operating instructions V04 Installation 3 3 4 Removing and changing the gas cartridge WARNING A The gas cartridge may only be replaced if the gas cartridge adapter is connected to the device and closed off if possible The different gas cartridges are removed and changed as follows gt If the gas cartridge adapter is equipped with a milled knob turn the knob fully clockwise in the OFF direction gt Remove the empty cartridge gt Fit a new cartridge gt If the gas cartridge adapter is equipped with a milled knob turn the knob fully counterclockwise in the ON direction The gas cartridge has been changed CAUTION STOP Gas will begin to flow 3 3 5 Connecting to the central gas supply or to a gas cylinder gt Connect the tubing from the central supply or from the gas cylinder to the previously installed adapter and fix it with a clip if necessary v FIREBOY plus is now connected to the gas supply 3 3 6 Setting the right flammable mixture The GAS KNOB gas can be used to set the gas supply and therefore the flame size while observing the flame itself Rotating the knob clockwise reduces the gas supply rotating it counterclockwise increases it The air knob air can be used to regulate the air supply and therefore the flame temperature Rotating the knob clockwise reduces the air supply rotating it counterclockwise increases it www integra biosciences com 15 FIREBOY plus Operat
3. 2 Description of the device Pur This chapter provides an overview of the FIREBOY plus and introduces the pose specific terminology 2 1 Scope of delivery FIREBOY plus device Power supply Nozzle P60 butane propane gas fitted ex factory Nozzle N80 natural gas Adapter for gas hose inner diameter 10 mm Operating instructions CAUTION Verify the scope of delivery when unpacking the device and check for potential transportation damage Do not operate devices that are damaged and contact your local dealer 2 2 Overview FIREBOY plus Front view 1 Burner head 2 LCD display 3 GAS KNOB to adjust the gas supply flame size 4 AIR KNOB to adjust the air supply flame temperature 5 MENU KNOB to switch the device on and off Rotary switch for selection of the operating mode with push function for user settings Ignites flame in the BUTTON mode www integra biosciences com 9 English FIREBOY plus Operating instructions V04 Description of the device 6 LCD display N 6 Motion sensor INTEGRA FIREBOY 7 Symbol of the set operating mode or caution YEN SENSOR note LI Ms Information regarding the device status Current operating mode with selected settings e g burning time or residual burning time Burner head 10 Ignition electrode 11 Burner chamber with flame opening 12 Electrode of the flame monitor Rear view 13 Switch connection jack 14 Mains plug socket mains plug 15
4. 60 Hz Output voltage 9 VDC 0 5 A Rechargeable battery optional Type NiMH 3 6 V Capacity at least 2000 mAh Charging time 12h Operating time 8h Operating conditions Operation 15 35 C 15 80 RH not condensing Storage 10 60 C 5 80 RH not condensing Nominal thermal rating Propane butane gas 1 6 kW Natural gas 1 0 kW Nominal gas input pressure Propane butane gas 50 mbar Natural gas 20 mbar 1 With a new fully charged battery in alternating operation switched on every 30s for 10s www integra biosciences com 23 English FIREBOY plus Operating instructions V04 Accessories 7 Accessories A variety of accessories are available which adapt FIREBOY plus to the respective application requirements and work environments 7 1 Accessories Part No Battery NiMH 3 6 V rechargeable 144 310 Accessories Gas cartridge adapter for 52 g butane 144 050 cartridge e g Campingaz CV 360 nee Gas cartridge adapter for 250 g butane 144 051 P cartridge e g Campingaz CP 250 with safety stand and connecting hose Gas cartridge adapter for 230 g butane 144 052 cartridge e g Campingaz CV 300 Plus with safety stand and connecting hose Gas cartridge adapter for EXPRESS 444 144 053 Foot switch and connecting cable 143 200 BQ INTEGRA Biosciences AG FIREBOY plus Operating instructions V04 Accessories A
5. Only use the nozzles supplied Prior to every nozzle installation inspect the O ring in the brass screw for damage and if necessary replace it INTEGRA Biosciences AG FIREBOY plus Operating instructions V04 Installation When replacing the nozzle proceed as follows gt Unscrew the brass screw 1 on the lower surface of the device using a small coin or screwdriver gt Turn over the device allow the nozzle to drop out and insert the desired new nozzle 2 gt Retighten the brass screw to the stop V The nozzle is now inserted 3 3 2 Installation and removal of the adapters for the gas connection The adapters for the central gas supply the gas cylinder or the gas cartridge are inserted in the gas adapter opening of the FIREBOY plus without the gas cartridge see Rear view on page 10 gt Insert the appropriate adapter in the gas adapter opening of FIREBOY plus making sure it audibly clicks into position The adapter is now installed WARNING A When replacing the adapters always switch off the device disconnect the mains plug and close off the gas supply gt In order to remove the adapter use a pointed tool to press the adapter mechanism inward on the lower surface of the device and remove the adapter by pulling toward the rear gt Insert the requested new adapter until it audibly clicks into position The adapter is now replaced www integra biosciences com 13 FIREBOY plus
6. Operating instructions V04 Installation 3 3 3 Connecting the gas cartridge The following gas cartridge types may be used e CV 360 about 30 min flame duration e CP 250 about 200 min flame duration e CV 300 Plus about 180 min flame duration e CV 470 about 400 min flame duration EXPRESS 444 about 35 min flame duration The gas cartridges can be purchased from a local dealer English WARNING A For operation with a gas cartridge the P60 nozzle must be inserted in the device and the gas cartridge adapter must be installed Gas cartridges may only be used at an ambient temperature of 15 35 C see note in the cartridge instructions The connection of the CP 250 CV 300 Plus CV 470 and EXPRESS 444 cartridges is described in the enclosed instructions The CV 360 gas cartridge is connected as follows gt Verify that the gas cartridge adapter is inserted and has audibly clicked into position gt Ensure that the smooth side of the cap 1 points toward the device gt Turn the milled knob on the cartridge adapter fully clockwise in the OFF direction gt Insert the gas cartridge into the cap until it audibly clicks into position Then open the gas cartridge adapter gt Turn the milled knob fully counterclockwise in the ON direction The gas cartridge is now open and ready for use The flame can now be ignited using any of the three operating modes 1400 INTEGRA Biosciences AG FIREBOY plus
7. Operating instructions V04 Introduction 1 1 3 Hazard warnings and caution notes on the LCD display The following symbols are displayed on the left in the LCD display see LCD display on page 10 CAUTION IN THE SENSOR MODE E5 Flame ignites automatically if object e g hand comes close to the sensor ATTENTION HOT fit Risk of burns from the device still being hot BATTERY EMPTY OPTIONAL co The symbol of the battery is displayed if no power supply is connected A flashing symbol indicates that the battery is almost empty and must be recharged 1 2 Appropriate use The FIREBOY plus is an automatic safety Bunsen burner for heating or flame sterilizing suitable laboratory materials For continuous operation over an extended period of time the optionally available long burner head see 7 1 Accessories on page 24 must be used FIREBOY plus may not be altered in design or in any of its safety aspects If alterations are made INTEGRA Biosciences will be relieved from all liability for any resulting damage 1 3 Safety features of the FIREBOY plus The FIREBOY plus is equipped with the following safety devices Ifthe flame has not ignited after about 3 seconds the flame monitor closes off the gas valve If the flame is inadvertently extinguished an attempt will be made to reignite it If this is not successful a message is displayed The burner chamber and the valve housing are monitored by a tem
8. circuit the battery i e do not bypass the two poles with a conductive object www integra biosciences com 11 English FIREBOY plus Operating instructions V04 Installation 3 2 2 Charging the battery During initial start up and when the battery symbol in the LCD display is flashing the battery must be charged This is performed directly in the device FIREBOY plus incorporates a charge protection device to prevent the battery from being overcharged This guarantees maximum battery life gt Connect the charger plug in the socket on FIREBOY plus and then connect to the mains The device can be turned on or off v After about 12 hours the battery is recharged The device may remain connected to the mains at all times 3 3 Connecting FIREBOY plus to the gas supply FIREBOY plus is appropriate for use with natural gas gas mixture gt 85 methane further alkanes and commercial butane propane gas mixture 65 10 butane 20 40 propane 3 3 1 Fitting the nozzle for the gas in use 12 The P60 nozzle for butane propane gas is fitted ex factory for FIREBOY plus If necessary the nozzle must be fitted for the gas in use Type of gas Gas input pressure Inscription Nozzle Natural gas methane 20 mbar N80 Butane propane gas 50 mbar P60 The nozzles are marked on the lower surface with the appropriate designation CAUTION FIREBOY plus may only be operated with the nozzle that corresponds to the gas type in use
9. Gas adapter opening for engaging T Bottom 16 Folding stand to position device at an angle 17 Brass screw access to the nozzle 18 Battery compartment 10 INTEGRA Biosciences AG FIREBOY plus Operating instructions V04 Installation 3 Installation Pur This chapter defines the requirements for the electricity supply and gas pose connection of FIREBOY plus 3 1 Connecting FIREBOY plus to the electricity supply FIREBOY plus can be used without the battery when using the power supply pack gt Insert the mains plug in the socket on the reverse side of the device see Rear view on page 10 and connect to the power source 3 2 Operating FIREBOY plus with optional battery FIREBOY plus can be operated independently from the electricity mains using an optionally available rechargeable battery see 7 1 Accessories on page 24 CAUTION Prior to the first start up the empty battery must be inserted in FIREBOY plus and charged on the mains without interruption for 12 hours 3 2 1 Inserting or replacing the battery gt Slide the cover of the battery compartment on the bottom of the device in the direction of the arrow gt If necessary remove the battery Insert the new battery in the direction of the arrow so that the blank parts on the inside point to the contacts of the device gt Close the cover counter to the direction of the arrow The battery is now replaced CAUTION Do not short
10. INTEGRA FIREBOY plus Operating instructions 144950 _VO4 INTEGRA Declaration of conformity Konformit tserkl rung D claration de conform Declaraci n de conformidad Dichiarazione di conformit INTEGRA Biosciences AG CH 7205 Zizers Switzerland declares on its own responsibility that the product erklart in alleiniger Verantwortung dass das Produkt d clare sous sa responsabilit exclusive que le product declara bajo su propia responsabilidad que el producto dichiara sotto la propria totale responsabilita che il prodotto Name Type model DVGW registration number FIREBOY plus 144000 NG 2211 AP 1042 in accordance with EC directives gem ss der EU Richtlinien est conforme au terme de la directives CE de acuerdo con las directivas CE in conformita alle direttive CE 2006 95 EC Low voltage equipment 2004 108 EC Electromagnetic compatibility 2011 65 EC Restriction of Hazardous Substances 2002 96 EC Waste Electrical and Electronic Equipment is in compliance with the following standards or normative documents mit den folgenden normativen Dokumenten bereinstimmt aux documents normatifs ci apr s cumple las normativas o documentos normativos soddisfa le normative seguenti EN 61010 1 Safety requirements for electrical equipment for measurement control and laboratory use General requirements EN 61326 1 Electrical equipment for measurement cont
11. RA Biosciences AG representative You can find the name and address at www integra biosciences com Further information and other languages are available on www integra biosciences com or on request info integra biosciences com INTEGRA Biosciences AG FIREBOY plus Operating instructions V04 Introduction 1 Introduction These operating instructions contain all information required for the commissioning operation and maintenance of the mobile safety Bunsen burner FIREBOY plus Pur This chapter provides information about the hazard symbols the appropriate pose use of the FIREBOY plus its safety features and the safety notes 1 1 Explanation of symbols 1 1 1 Hazard warnings in these operating instructions These operating instructions specifically advise of residual risks with the following symbols WARNING This safety symbol advises of hazards that could result in injury or death It also indicates hazards for machinery materials and the environment It is essential that you follow the relevant precautions CAUTION This symbol cautions about potential material damage or data loss in a microprocessor controller Follow the instructions NOTE This symbol identifies important notes regarding the correct operation of the device and labor saving features 66 gt 1 1 2 Hazard warnings on the device ATTENTION HOT Risk of burns from the flame gt www integra biosciences com 5 English FIREBOY plus
12. SOR operating mode 18 4 6 Adjusting the system parameters 19 4 7 Working with liquids 20 4 8 Troubleshooting 2 458 ment elated lene 20 Chapter 5 Maintenance 5 1 Cleaning and Servicing cceceeeceeeeceeeeeeeeeeeeeeeeeeeeseaeeseaeeneeeeaees 22 D 2 DISPOSal EEEE ATT ATA 22 Chapter 6 Technical data GA Specification S econo tui we wal aa i ode 23 Chapter 7 Accessories Pel SACCESSORIES AAA A EERE AR PT EE A E AE EEE A 24 www integra biosciences com 3 English FIREBOY plus Operating instructions V04 Imprint Manu facturer Custo mer service 2013 INTEGRA Biosciences AG All rights relating to this documentation reserved INTEGRA Biosciences AG especially reserves the rights of duplication processing translation and display format Any reproduction of parts or the entire documentation or storage thereof on electronic media or processing or dissemination thereof require the prior written consent of INTEGRA Biosciences AG These operating instructions have the part number 144950 the version is V04 They apply for firmware Version 1 n INTEGRA Biosciences AG INTEGRA Biosciences Corp CH 7205 Zizers Switzerland Hudson NH 03051 USA T 41 81 286 95 30 T 1 603 578 5800 F 41 81 286 95 33 F 1 603 577 5529 info integra biosciences com www integra biosciences com Please contact your local INTEG
13. V04 Operation Parameter Description Range pasie setting SENSOR Setting the burning time of the 1 s 60 min 10s flame s Of course the flame can be extinguished at any time by passing the sensor window again or by pressing the MENU KNOB 4 6 Adjusting the system parameters Within the SETTINGS menu bring up the following functions by rotating the MENU KNOB to the right Parameter Description Range Basie setting Language Setting the desired language English English Deutsch Fran ais Italiano Espa ol Maximum Setting the maximum burning time 1 60 min 1 burning time in the BUTTON operating mode off Automatic Definition of how many minutes 1 60 min 15 min shut off after the last use the device shuts off off automatically Sensor Setting the sensor sensitivity low middle sensitivity in 3 sensitivity stages middle high Sensor Setting whether the sensor 1x 2x activation must be activated 1x or 2x 2x successively to ignite the flame Default Restores the default settings from no no settings the factory yes Info Information regarding the firmware for the service technician Exit settings Return to the operating modes FOOT SWITCH www integra biosciences com 19 FIREBOY plus Operating instructions V04 Operation 4 7 Working with liquids In order to protect the burner chamber from contamination when working with liquids the folding stand at the base of FIREBOY plus can be use
14. age 20 If the burner head gets soiled it can be removed for cleaning purposes see 3 5 Removing and adding the burner head on page 16 and cleaned with commercially available disinfecting or cleaning agents It can also be replaced with a new one see 7 1 Accessories on page 24 CAUTION Ignition and flame monitoring electrodes white ceramic posts only tolerate low mechanical forces In the event of an error carefully clean the ignition electrode with a lint free cotton swab saturated with 70 ethanol solution If any of the ceramic posts is loose or broken the burner head must be replaced For proper function all three contact pins and their correspondent spring contacts must be clean and free of corrosion Same applies for the burner head shaft plug and the burner chamber socket especially the spring loaded ball lock pin and the nozzle with orifice pinhole 5 2 Disposal 22 The FIREBOY plus device must not be disposed of with unsorted municipal waste Dispose of the FIREBOY plus in accordance with the laws and regulations in your area governing disposal of devices INTEGRA Biosciences AG FIREBOY plus Operating instructions V04 Technical data 6 Technical data 6 1 Specifications Device Type Safety Bunsen burner Dimensions W x D x H 100 x 150 x 60 mm without burner head Weight 1 3 kg Mains adapter Input voltage 100 240 VAC 50
15. ccessories oo ee No E Benchtop switch and connecting cable 171 081 p Windshield for hoods 143 205 Borosilicate glass splash protector 143 210 Burner head 144 300 Long burner head for continuous operation 144 306 Mains adapter Europe 230 VAC 156 631 Mains adapter UK 240 VAC 156 632 Mains adapter US 120 VAC 156 630 Mains adapter AU 240 VAC 156 633 Mains adapter JP 100 VAC 156 634 Gas safety tubing 10 mm Length 2 m 140 055 max pressure 100 mbar DVGW approved Adapter for gas hose inner diameter 10 mm 144 240 Adapter for 1 4 left hand thread 144 227 www integra biosciences com 25
16. d to incline the device The inclination direction can be modified by removing the folding stand after pressing it together and inserting it on the opposite side 4 8 Troubleshooting Warnings and notes are shown at the top left of the LCD display see LCD display on page 10 A differentiation is made between the following types Symbol Description Technical notes e g BURNER HEAD MISSING i Notes for the user e g CHECK GAS In the event of an error the flame is automatically extinguished Every message must be confirmed by pressing the MENU KNOB The device then assumes the operating mode set last The following table lists the possible error messages and the recommended action for elimination 20 INTEGRA Biosciences AG FIREBOY plus Operating instructions V04 Error message Technical cause CHECK GAS The flame monitor does not detect a flame The valve is closed The nozzle is blocked Operation Possible cause and correction No gas supply is connected gt Connect the gas supply gt Open the gas connection Flame was blown out several times gt Correctly set the gas air mixture gt Prevent draft Electrode of the flame monitor is broken or dirty gt Visually inspect electrode gt Clean electrode with alcohol Nozzle is soiled and blocked gt Remove nozzle pierce with a needle and clean it BURNER HEAD Prior to ignition Burner head not added or not
17. h the FIREBOY plus Work only in well ventilated areas Do not use the FIREBOY plus near flammable material or in explosive areas Use only approved and tested safety gas tubing with threaded or hose connectors and inspect the device regularly for damage Firmly tighten all gas connections and verify gas tightness using test equipment Never remove the gas cartridge adapter while it is connected to the gas cartridge Use only original INTEGRA Biosciences power supply pack or original INTEGRA Biosciences rechargeable batteries Switch off the device before removing or inserting the optional rechargeable battery Observe the hazard warnings on the device www integra biosciences com 7 FIREBOY plus Operating instructions V04 Introduction The gas supply must be closed off when e the device is being transported or installed e the gas cartridge is being changed extended breaks are taken and after the work has been completed cleaning and repair work is being performed the rechargeable battery or adapter is being replaced English 1 43 Restrictions for use The following uses of the FIREBOY plus are prohibited A e rotating it and using it upside down ti 7 1 Accessories on page 24 carrying it by the burner head because the device may fall down using it as a cooker without the optionally available long burner head see INTEGRA Biosciences AG FIREBOY plus Operating instructions V04 Description of the device
18. ing instructions V04 Installation 3 4 Connecting the foot or benchtop switch English gt Insert the plug of the foot or benchtop switch in the socket on the reverse side of the device see Rear view on page 10 Y The switch is now connected 3 5 Removing and adding the burner head o gt To remove the burner head pull it out vertically upward gt To install the burner head place it on the device with the 3 contact pins and push it down vertically until it clicks into position The burner head is now reinstalled CAUTION Never carry the device by the burner head 3 6 Long burner head 16 If the FIREBOY plus is used for continuous operation the optionally available long burner head must be used For installation see previous section CAUTION The minimum distance between the tip of the burner head and the object to be heated e g cover plate of quadrupod must be at least 60 mm The duration of continuous operation should not exceed 60 min The parameter Maximum burning time must be set accordingly see 4 6 Adjusting the system parameters on page 19 INTEGRA Biosciences AG FIREBOY plus Operating instructions V04 Operation 4 Operation Pur This chapter explains the different operating modes of FIREBOY plus and pose explains the adjustments of the general device settings In addition the steps to be taken in the event of an error are described 4 1 Switching FIREBOY plus
19. kground Press www integra biosciences com 17 English FIREBOY plus Operating instructions V04 Operation the MENU KNOB to set a time During operation the LCD display shows the countdown TRE Basic Parameter Description Range setting FOOT SWITCH Setting the burning time of 1 s 60 min off D the flame In addition the flame can be extinguished at any time by actuating the foot switch again or by pressing the MENU KNOB 4 4 BUTTON operating mode In the BUTTON operating mode the flame is ignited and also extinguished by pressing the MENU KNOB NOTE For safety reasons the maximum burning time is factory set to 1 min Go to SETTINGS 4 6 Adjusting the system parameters on page 19 to change the parameters 4 5 SENSOR operating mode 18 In the SENSOR operating mode the flame is ignited if an object passes the sensor window with a maximum distance of 6 8 cm CAUTION For safety reasons it is recommended not to change the factory setting of SENSOR 2x activation see 4 6 Adjusting the system parameters on page 19 n this setting the flame is only ignited if the sensor is activated two times in quick succession This almost excludes inadvertent ignition Adjust the duration of the flame to between 1 second and 60 minutes by rotating and then pressing the MENU KNOB During operation the LCD display shows the countdown INTEGRA Biosciences AG FIREBOY plus Operating instructions
20. on and off FIREBOY plus is switched on by briefly pressing on the MENU KNOB It is switched off by pressing the knob for at least 2 seconds If the burner is still hot initially the ATTENTION HOT symbol appears on the bottom left of the LCD display After the cooling period the device switches off automatically If the device has not been operated in 15 minutes it is switched off automatically to save energy This can be changed in SETTINGS see 4 6 Adjusting the system parameters on page 19 4 2 Overview of menu functions Rotate the MENU KNOB to switch between the operating modes and select them by pressing down e FOOT SWITCH Flame is ignited via the foot or benchtop switch BUTTON Flame is ignited by pressing the MENU KNOB SENSOR Flame is ignited if an object passes the sensor SETTINGS To set the general system parameters In several operating modes repeated pressing displays adjustable parameters on a black background These can be changed by rotating the MENU KNOB and confirmed by pressing 4 3 FOOT SWITCH operating mode In the FOOT SWITCH operating mode the flame is ignited only if the foot or benchtop switch is activated The flame burns only as long as the switch is depressed Timer off Alternatively a fixed duration of the flame can be defined Press the MENU KNOB to bring up the timer The timer can be set between 1 second and 60 minutes by rotating it The possible times have a black bac
21. perature sensor If the temperature exceeds the safety level the gas valve is automatically closed off 6 INTEGRA Biosciences AG FIREBOY plus Operating instructions V04 Introduction 1 4 Safety notes 1 4 1 Operation of the FIREBOY plus regulations and is safe to operate The FIREBOY plus may be operated only in The FIREBOY plus corresponds to state of the art and recognized safety A flawless condition while observing these operating instructions The device may be associated with residual risks if it is used or operated improperly by untrained personnel Any person charged with the operation of the FIREBOY plus must have read and understood these operating instructions and particularly the safety notes or must have been instructed by the supervisors so that safe operation of the device is guaranteed Regardless of the listed safety notes additionally applicable regulations and guidelines of the trade associations the health authorities and the trade supervisory office e g GLP GMP FDA must be observed 1 4 2 General safety notes A Do not carry out any conversions and alterations on the device Defective parts may only be replaced with original INTEGRA Biosciences spare parts Do not open the FIREBOY plus Repairs may only be performed by INTEGRA Biosciences or an authorized after sales service member The device may be operated only under constant supervision Always wear protective goggles when working wit
22. rol and laboratory use EMC requirements Standards for Canada and USA CAN CSA C22 2 Safety requirements for electrical equipment for measurement No 61010 1 control and laboratory use General requirements UL Std No 61010 1 Safety requirements for electrical equipment for measurement control and laboratory use General requirements FCC Part 15 Class A Emission Zizers April 9 2013 8 luide FV Me Elmar Morscher Thomas Neher CEO Quality Manager FIREBOY plus Operating instructions V04 Table of contents Chapter 1 Introduction 1 1 Explanation of Symbol Sraa a aaa 5 1 2 Appropriate Use rene nine ainda tees 6 1 3 Safety features of the FIREBOY plus 6 1 4 Safety notes jonasn oie eni grenier ht 7 Chapter 2 Description of the device 2 1 Scope Of deliVerv sine seine 9 2 2 Overview FIREBOY plus 9 Chapter 3 Installation 3 1 Connecting FIREBOY plus to the electricity supply 11 3 2 Operating FIREBOY plus with optional battery 0 0 0 eee 11 3 3 Connecting FIREBOY plus to the gas supply 12 3 4 Connecting the foot or benchtop switch 16 3 5 Removing and adding the burner head 16 3 6 Long burner head ane sites asedeaddsstsensapeeeaseds 16 Chapter 4 Operation 4 1 Switching FIREBOY plus on and off 17 4 2 Overview of menu functions 17 4 3 FOOT SWITCH operating mode 17 4 4 BUTTON operating mode 18 4 5 SEN