1. Please keep these instructions safe Should you move house please hand them over to the next occupier Baxi Solo 3 PF Wall Mounted Powered Flue Gas Fired Central Heating Unit User s Operating Instructions Natural Gas Baxi Solo 3 30 PF G C No 41 075 04 Baxi Solo 3 40 PF G C No 41 075 05 Baxi Solo 3 50 PF G C No 41 075 06 Baxi Solo 3 60 PF G C No 41 075 07 Baxi Solo 3 70 PF G C No 41 075 08 Baxi Solo 3 80 PF G C No 41 075 09 Baxi UK Limited is one of the leading manufacturers of domestic heating products in the UK Our first priority is to give a high quality service to our customers Quality is built into every Baxi product products which fulfil the demands and needs of customers offering choice efficiency and reliability To keep ahead of changing trends we have made a commitment to develop new ideas using the latest technology with the aim of continuing to make the products that customers want to buy Baxi is also the largest manufacturing partnership in the country Everyone who works at the company has a commitment to quality because as shareholders we know that satisfied customers mean continued SUCCESS We hope you get a satisfactory service from Baxi If not please let us know Baxi is a BS EN ISO 9001 Accredited Company The boiler meets requirements of Statutory Instrument The Boiler Efficiency Regulations 1993 N 3083 and is deemed to mee
2. n turn off the gas supply at either the appliance gas cock or the meter BER Frost Protection 1 The appliance incorporates a frost protection thermostat that will light the appliance when it s temperature falls to near freezing Note that this is designed to protect the boiler only the system pipework may require the protection of an additional stat 2 To set the appliance to frost protection but without normal heating Set the control knob to the position Fig 2 3 The frost protection will only operate if gas and electrical supplies are switched on 3 0 Overheat Cut Off Device ERM Overheat Cut Off Device 1 Your boiler is fitted with an additional safety device which shuts down the appliance should the system overheat The overheat indicator light will be illuminated if the appliance needs resetting NOTE Any interruption to the electricity supply may cause the device to operate In the case of persistant operation of the device turn off the boiler and consult your service engineer as an appliance or system fault is indicated ER Resetting 1 To reset the device follow these instructions 2 Allow the boiler to cool if hot 3 Remove the lower door panel by following the Fig 4 sequence of diagrams Fig 4 5 Turn the boiler thermostat control knob fully anti clockwise to the OFF position marked 0 Fig 5 6 Wait 10 seconds 7 Turn the control knob clockwise to the re
3. n the customer and the installer or supplier from whom the unit was purchased remain intact Any component or part which becomes defective during the guarantee period as a result of faulty workmanship or material whilst in normal use will be repaired or replaced free of charge Comp N 244097 Iss 4 7 00 The Baxi Helplines For General Enquiries 44 0 8706 060 780 For After Sales Service 44 0 8706 096 096 For Technical Enquiries 44 0 8706 049 049 BAXI Baxi UK Limited Brownedge Road Bamber Bridge Preston Lancashire PR5 6SN www baxi com
4. o the outside through the flue terminal which must be kept free from obstruction as this would interfere with the correct operation of the boiler 5 0 Cleaning Spares amp Guarantee ERM Cleaning the case 1 The painted panels should be wiped with a damp cloth and then dried completely DO NOT USE ABRASIVE CLEANING AGENTS EZ Spare Parts 1 Any repairs to the appliance will usually be the responsibility of the Installer during the guarantee period after which spare parts may be obtained through approved Baxi stockists if required 2 Quote the appliance name model number and where possible the part number when ordering spares An abbreviated data plate with this information is inside the removable door A parts list is included in the Installation and Servicing Instructions Only a CORGI registered or other competent person should service this appliance 5 3 Guarantee 1 Your Baxi Solo 3 is designed and produced to meet all the relevant Standards and EU directives 2 Baxi UK Limited provide a 12 month guarantee on the Boiler other parts of the system are covered by the Installer or other manufacturers The guarantee operates from the date installation is completed for the customer who is the original user 3 To maximise the benefit from our guarantee we urge you to return the reply paid guarantee registration 4 This does not in any way prejudice your rights at Common Law Such rights betwee
5. quired thermostat setting the overheat light will go out and the boiler will commence sparking and fire up automatically when the boiler has sufficiently cooled Fig 6 8 No adjustments to the gas controls or boiler thermostat are required OO M rg 6 C a o 2 6 a O Pilot On O Burner On CE Overheat Neon Warning THERMOSTAT KNOB Fig 5 Fig 6 5mm 5mm 5mm during operation gt 350mm 30 40 50 models lt y 462mm 60 70 80 models 50mm C 600mm 100mm A x 287mm 300mm for servicing Fig 7 4 0 Clearances 4i Clearances around the boiler Fig 7 1 The minimum clear spaces needed around the boiler are Top 50mm 2 in Bottom 100mm 4 in Sides 5mm s in Front 5mm 6 in 2 These clearances must not be obstructed in any way Blocking the clearance spaces will result in the appliance overheating and possible damage may occur 3 The boiler may be installed in a cupboard if these minimum clearances are kept Note that the label affixed to the front of the boiler must be left in place to ensure future servicing is successfully undertaken 4 The compartment should be large enough to house the boiler and ancillary equipment only 5 IT SHOULD NOT BE USED AS A STORAGE CUPBOARD 6 The gas burning compartment of your boiler is completely sealed from the room in which it is fitted Products from the combustion of gas are vented t
6. stered Installer or other competent person and be in accordance with the relevant requirements of the current Gas SAFETY Installation and Use REGULATIONS the BUILDING REGULATIONS Scotland Consolidation the Loca BuiLDiNG REGuLATIONS the CuRRENT I E E WIRING REGULATIONS and the bye laws of the Local Water Undertaking Where no specific instructions are given reference should be made to the relevant BRITISH STANDARD CODES OF PRACTICE Read the instructions before installing or using this appliance IMPORTANT The addition of anything that may interfere with the normal operation of the appliance without the express written permission of Baxi UK Limited could invalidate the appliance warranty and infringe the Gas Safety Installation amp Use Regulations WARNING Sealed components must not be interfered with Never hang clothes or other items over the appliance E n case of gas leaks 1 If a gas leak is found or suspected turn off the gas supply at the meter immediately and contact your Installer or Local Gas Supplier Emergency Service under Gas in the phone directory BEM Servicing your boiler 1 We strongly recommend that your Boiler is serviced annually by a competent person for economic and safety reasons Your Installer or British Gas Service will be able to advise you EEJ Electricity supply 1 THIS APPLIANCE MUST BE EARTHED A standard 230 volt 50Hz supply is required The appliance m
7. t the requirements of Directive 92 42 EEC on the efficiency requirements for new hot water boilers fired with liquid or gaseous fuels Type test for purpose of Regulation 5 certified by Notified Body 0086 Product Production certified by Notified Body 0086 For GB IE only Benchmark Installation Commissioning and Service Record Log Book Please ensure that your installer has completed the Installation and Commissioning sections of the Log Book and hands the Log Book over The details of the Log Book will be required in the event of any warranty work Keep the Log Book in a safe place and ensure that the relevant sections are completed at each subsequent regular service visit All CORGI registered installers carry a CORGI identification card and have a registration number Both should be recorded in your boiler Log Book You can check your installer is registered by telephoning 01256 372300 or writing to 1 Elmwood Chineham Business Park Crockford Lane Basingstoke RG24 8WG WARNING If it is either known or suspected that a fault exists on the appliance it must not be used until the fault has been corrected by a competent person EE Safe Installation 1 This appliance must be installed in accordance with the manufacturers instructions and the rules in force For Ireland install in accordance with 1 813 INSTALLATION OF GAS APPLIANCES The installation must be carried out by a CORGI Regi
8. ust be protected by a 5 amp fuse Overheat Neon Warning Fig 3 O D E D gt 0 Boiler On CE Fig 1 Your Baxi Solo is a gas fired room sealed fan assisted central heating boiler providing heating for your home and domestic hot water where required O O Burner On O THERMOSTAT KNOB To shut down the boiler turn fully anti clockwise Fig 2 2 0 Operating the Boiler EAJ Operating the Boiler 1 Remove lower door panel as shown Fig 1 2 Turn the boiler thermostat knob to the O position fully anti clockwise Fig 2 3 Turn on the main gas and electricity supplies to the appliance 4 Set the thermostat control knob to the required setting The optimum boiler setting depends upon type of system external controls and your requirements Your installer will be able to advise you on this matter 5 The fan will start to run and after a short period of time the ignition spark will commence Sparking will continue until the pilot flame is established then stop automatically The main gas will then come on and the burner will light from the pilot flame Check that both the main burner and the pilot are alight by looking through the viewing window The bottom four indicator lights should also be illuminated Fig 3 E To shut down the boiler 1 Turn off the electricity supply to the appliance at the mains 2 Turn the thermostat knob to zero Fig 2 the

Download Pdf Manuals

image

Related Search

Related Contents

Sección 4: Instrumentos, Controles y Mandos 59 1  Vélo d`appartement Manuel d`utilisation    Levures liquides pour bière Wyeast Mode d`emploi  IBM Lotus Live - InterCall  Manual de Usuario SIDUNEA++ Introducción  voir le sommaire  Installation Instructions SentrySuite®    「Dance Station 」6 月 1 日に新発売!  