1. in sequence a record of the system events The last door closed or detector operated by the user on exit Liquid Crystal Display An alarm circuit which cannot be omitted bypassed by the user The unit comprising the LCD display and buttons that is the interface between users and the system Setting the system with alarm zones excluded from the system Only zones programmed as omittable by the engineer can be omitted Panic Alarm an emergency button or switch used to set off the alarm results in instantaneous transmission of a silent alarm signal using the remote signalling de vice To set only a section of the full system To alter the system functions or parameters To arm the system To disarm the system A four digit code that identifies users to the system A routine test of the alarm detectors An alarm circuit which has been programmed to be armed continuously whether the system is set or not ix KEYPAD INFORMATION The Galaxy system is programmed and operated from the LCD keypads 2 x 16 CHARACTER LCD DISPLAY GALAXY 16 V2 XX 06 22 TUE 30 JUN POWER LED ne Figure 1 Galaxy Mk III LCD Keypad Number Keys 0 9 are used to enter your User Code and to select and modify options View A and B Keys are used to set the system and to step through the menu options during programming Enter ent Key The ent key allows you to unset the system to acce
2. routine is initiated the keypad sounders will emit a continuous tone and the keypad displays the Exit Time countdown blocks If any zones are open for example protected doors or windows or if someone activates a movement detector when the setting process is started then the keypad sounders pulse rapidly and the keypad displays which zones are open Closing the open zones allows the setting routine to restart Leave the building using the agreed Exit Route Close and lock the Final Exit Door and then if fitted operate the Exit Terminator the horn outputs and the keypad buzzers become silent for four seconds the countdown blocks all clear and the keypad buzzers emit two long tones to confirm that the system is Set On the keypad the message SYSTEM IS SET appears before the dis play goes blank The setting routine can be aborted before the system sets by pressing the esc key on the keypad used to initiate the setting routine Part Setting the System Your alarm system can be Part Set using the B key To Part Set the system enter your User Code then press the B key The keypad then displays the Set Unset status of those parts assigned to your code see Figure 2 Part Setting Options Part Set options for user code SELECT P1 OFF with Parts 1 and 3 assigned P3x0N Part 1 is unset Part 3 set Figure 2 Part Setting Options The Parts marked ON are Set those marked OFF are Unset To alter the set unset
3. GALAXY 16 and 16 plus User s Guide GALAXY 16 V2 XX 06 22 TUE 30 JUN Contents INTRODUCTION amp 2 ee v QUICK OPERATION GUIDE ooooccccccccccccccccncnnnnnncnannnnncnnnnonnncnnnonos vii GLOSSARY OF TERMS uususuunsunnnannnnnnnnnnnanannnnnnnnnnnnnnnnnnnn ix KEYPAD INFORMATION cococccccccccconccnnnnnnnnnnnnnnnnnnnnnnnncnnnnnnnnnnnnnas 1 Star X Key Features die nin einen 2 SETTING AND UNSETTING THE SYSTEM 2 eeeeeeeees 3 setting the Systema da aus nee ean 3 Unsetting the System ished iia ed 4 Cancelling Alas ai 5 USER MENU aiii ti 7 OPINA OM AS ee EE E A E E E 7 Option 2 CHIME sien anna in 8 Option 3 Walk occcccccccccccinnnnnnnnnnnnonononnnnnnnnonnnnnnononononnnnncnnnnncnnnnnnnnns 8 Option 4 CodeS niri an inde Bi 9 Option 5 Testiin n s nen anne anna iii 10 Option 9 LOG i Anchen ie ihr 11 Option 10 Time er ana ei iene 12 APPENDIX A ALARM AND HELP MESSAGES 13 APPENDIX B AVOIDING FALSE ALARMS uuuuuuuunnnunnn 15 ZONE REFERENCE TABLE ceeees eeeeeeeeeeeeeeeeeseeeeeeeeeeees 17 iii INTRODUCTION The Galaxy 16 and 16 plus control panels are designed to the highest speci fications and requirements using the most advanced software and hardware technology The Galaxy 16 and 16 plus are designed to satisfy the requirements of do mestic and smaller commercial installations yet are flexible enough to pro vide ea
4. eypad Engineer Reset Certain types of alarm require an engineer to visit the site and after investi gation reset the system USER MENU For access to the menu options enter your user code then press the ent key The keypad then displays the menu options available to the user
5. ramming esc to cancel TEST OUTPUTS A or B key to select output for test key to enable disable test function on zone esc key to end test LOG A key to step forwards through events B key to step backwards through events key to display event date esc key to exit Log TIME To access the Time option enter your user code press the ent key the B key and then the ent key Then press the 1 key to select Time hh mm 2 key to select Date dd mm yy 3 key to select Start Summer dd mm 4 key to select End Summer dd mm Press the ent key to accept the programming for each option or the esc key to cancel vii Chime Duress Entry Time Exit Time Exit Terminator Event Log Final Exit LCD Non omit Numeric Keypad Omit PA Part Set Programme Set Unset User Code Walk Test Security Circuit GLOSSARY OF TERMS Zone attribute which gives an audible indication of the activation of a detector or contact Applicable when a remote signalling device is fitted A Duress code entered at the keypad will unset the system but transmit a Duress code to the Alarm Re ceiving Centre The preset time allowed for users to reach the keypad and unset the system The preset time allowed for users to leave the building after the setting routine has been initiated A switch or push button located outside the protected area and used to set the system The control panel memory which stores
6. se of use and operational versatility This User s Guide contains the information required to operate the system The installation engineer will program and commission the system to meet your requirements The system is simple to operate but users are advised to read this guide carefully before using the system and retain it in a safe place for future reference B m ent ENTER YOUR USER _ CODE THEN SELECT T ent B QUICK OPERATION GUIDE SET an Unset system PART SET Defaults to Parts 1 and 2 1 key toggles the Set ON Unset OFF status of Part 1 2 key toggles the Set ON Unset OFF status of Part 2 3 key toggles the Set ON Unset OFF status of Part 3 UNSET a Set system OMIT ZONES A or B key to view zones to change omit status of zone must be an omittable zone ent key to accept programming and start setting esc key to accept programming without setting CHIME ZONES A or B key to view zones key to enable disable chime function on zone ent key to accept esc key to cancel WALK TEST A or B key to view zones key to enable disable Walk Test function on zone ent key to start Walk Test key to toggle display between open and tested zones esc key to end Walk Test Note Zones number 10 to 16 will be displayed as A to G ASSIGNING USER CODES A or B key to select user 1 14 ent key to program code number keys to enter digits key to delete digits ent key to accept prog
7. ss the menu options and to accept programming selections Escape esc Key The esc key permits you to cancel any modifications made to a menu option and allows you to return to the previous menu option level The esc key also aborts the setting routine if pressed during the Exit time from the same keypad used to initiate the setting Hash Key The key is used as a toggle key which enables or disables the programming features of certain menu options It is also used to select the user attributes feature in menu option 4 Codes Star Key The key when combined with other keys provides special functions The engineer will advise of these where applicable see also Star Key Features Power LED The green power LED remains lit whenever the system is con nected to the a c mains power supply and a charged stand by battery A mains power failure is indicated by the LED flashing slowly A fuse or bat tery failure is indicated by the LED flashing quickly Your User Code is a four digit personal identification number which iden tifies you to and allows you to operate the system Note Entry of an invalid code will cause the keypad to display the message INVALID CODE Entry of six consecutive invalid codes will cause a ten minute keypad lockout during which the keypad horns activate and the keypad displays the message ALARM IS ACTIVE No further code entries will be recognised during the lockout period Star x Key Fea
8. status of a Part press the number corresponding to that part that is pressing the 1 key toggles the set status of Part 1 between set unset The equals sign denotes that what is displayed beside the Part number is the current status of the Part that is PI ON denotes that Part 1 is currently set Pressing the 1 key will cause the display to read P12 OFF this means that Part is now provisionally programmed as Unset The actual set status of the part will not be altered until the ent key is pressed to accept the programming Once the ent key has been pressed leave the building using the agreed exit route Close and lock the final exit door and then operate the exit terminator the horn outputs and the keypad buzzers become silent for four seconds the countdown blocks on the keypad display all clear and the keypad buzzers emit two long tones to confirm that the system is set On the keypad the message SYSTEM IS SET appears before the display goes blank The setting routine can be aborted before the system sets by pressing the esc key on the keypad used to initiate the setting routine Note Ifthe Silent Part Set facility has been enabled only the keypad display indicates the setting status that is no audible tones are emitted Unsetting the System Normal Entry The system begins the unsetting routine whenever a Final door opens or an Exit Entry zone is activated The keypad buzzers pulse slowly indicating that the Entry Time countdo
9. tures The star key is used as a shift key when combined with other keys it provides additional system features To toggle the enable status of the Star key features enter either the manager code User 14 at the keypad and then hold down the Star key and press the esc key after a second the keypad displays ENABLE ON or X ENABLE OFF release both keys Key Combination Star Feature 1 Changes keypad buzzer volume 2 Activates PA alarm Mgr Code 3 Toggles On Off to authorise Galaxy Gold connection 4 Toggles keypad backlighting On Off 5 Activates Medical alarm Code 6 Prints the entire system details Code 7 Prints the entire event log 8 Activates the Fire alarm x9 Initiates the Engineer s Test xH Indicates zone statuses Mgr Code ent Activates the Galaxy Gold Call Back Mer Code Xesc Toggles key featues On Off Galaxy 16 plus only Table 1 Star Key Features Note The Star mode must be enabled for the Star features to operate SETTING AND UNSETTING THE SYSTEM Setting the System Before Setting the System Before the system is Set ensure that All doors and windows are secured e All areas protected by movement detectors are free from obstructions and any animals are excluded from the areas to be protected Full Setting the System Enter your User Code and press the A key e Ifall the system zones are closed when the setting
10. wn has started To unset the system go directly to the keypad using the agreed entry route enter your code and press the ent key Slow Entry The keypad sounder begins to pulse rapidly after 75 of the entry time has expired to indicate that time is running short If the entry time expires before a valid user code is entered a full alarm occurs Straying From The Entry Route If during the entry routine you stray from the agreed entry route and activate a zone in a protected area an audible alarm occurs Alarm Abort Note Ifthe system is programmed for Alarm Abort a period of 90 seconds after expiry of the Entry Time is provided to enable the user to cancel an alarm caused by exceeding the Entry Time or deviating from the entry route If the 90 second Alarm Abort time is exceeded then a full alarm may result in the Police being called to the premises and the system requiring an Engineer Reset The installation engineer will explain the operation of the Alarm Abort func tion where necessary Cancelling Alarms To cancel an alarm enter your user code The keypad displays the zones that have been activated during the alarm Press the esc key to return to the nor mal display Certain types of alarms once cancelled require a code authorised with the appropriate reset authorisation to be entered The system prompts for a valid reset code by displaying INTRUDER RESET REQUIRED PA RESET RE QUIRED or ENGINEER RESET REQUIRED on the k

Download Pdf Manuals

image

Related Search

Related Contents

LCD Projector User`s Manual - NEC Display Solutions Europe  stream 6080 6100 6110  MPEG2+4 Codec Manual..  Carson Optical MM-200 User's Manual  Installazione - Support Sagemcom  La Germania K9 G9 X cooker hood  Manual de instruções  Carte de communication JBUS/MODBUS    Speco Technologies CVC-6405DC User's Manual  