Upsolar Installation Manual

image

Contents

1. Black type Module type UP M290M B UP M295M B UP M300M B UP M305M B UP M310M B Pm Wp 290 295 300 305 310 Vin V 36 0 36 2 36 4 36 6 36 8 Im A 8 06 8 15 8 24 8 33 8 42 Voc V 45 0 45 3 45 6 45 9 46 2 lsc A 8 54 8 62 8 70 8 78 8 86 Maximum System voltage IEC 1000V 1000V 1000V 1000V 1000V Maximum System voltage UL 600V 600V 600V 600V 600V Maximum Reverse Current 20A 20A 20A 20A 20A EN 6 SECES Modules rating at STC Standard Test Conditions Module type UP M210P UP M215P UP M220P UP M225P UP M230P Pm Wp 210 215 220 225 230 Vm V 26 8 27 2 274 27 6 27 8 Im A 7 84 7 91 8 03 8 15 8 27 Voc V 33 3 33 4 33 5 33 6 33 7 Isc A 8 40 8 47 8 54 8 61 8 68 Maximum System voltage IEC 1000V 1000V 1000V 1000V 1000V Maximum System voltage UL 600V 600V 600V 600V 600V Maximum Reverse Current 20A 20A 20A 20A 20A Wa eia nb Modules rating at STC Standard Test Conditions Module type UP M210P B UP M215P B UP M220P B UP M225P B UP M230P B Pm Wp 210 215 220 225 230 Vm V 27 0 27 4 27 6 27 8 28 0 Im A 7 79 7 85 7 97 8 09 8 21 Voc V 33 5 33 6 33 7 33 8 33 9 Isc A 8 35 8 42 8 49 8 56 8 63 Maximum System voltage IEC 1000V 1000V 1000V 1000V 1000V Maximum System voltage UL 600V 600V 600V 600V 600V Maximum Reverse Current 20A 20A 20A 20A 20A Wea Gr et celle Modules rating at STC Standard Tes
2. 600V 600V 600V 600V 600V Maximum Reverse Current 15A 15A 15A 15A 15A White type Solr PS m Modules rating at STC Standard Test Conditions Module type UP S185MT UP S190MT UP S195MT UP S200MT UP S205MT Pm Wp 185 190 195 200 205 Vm V 36 0 36 3 36 6 37 0 37 4 Im A 5 14 5 23 5 39 5 41 5 48 Voc V 44 8 45 1 45 4 46 0 46 6 Isc A 5 43 5 55 5 65 5 70 5 75 Maximum System voltage IEC _1000V 1000V 1000V 1000V 1000V Maximum System voltage UL 600V 600V 600V 600V 600V Maximum Reverse Current 15A 15A 15A 15A 15A www upsolar com Upsoler Delivering safe solar Bree Es Peis Mas Modules rating at STC Standard Test Conditions Module type UP S185MT B UP S190MT B UP S195MT B UP S200MT B UP S205MT B Pn Wp 185 190 195 200 205 Vm V 36 4 36 6 36 8 37 37 2 Im A 5 08 5 19 5 30 5 41 5 51 Voc V 45 0 45 3 45 6 45 9 46 2 lsc A 5 30 5 40 5 50 5 60 5 70 Maximum System voltage IEC _ 1000V 1000V 1000V 1000V 1000V Maximum System voltage UL 600V 600V 600V 600V 600V Maximum Reverse Current 15A 15A 15A 15A 15A White type ZEP frame COLS Modules rating at STC Standard Test Conditions Module type UP Z185MT UP Z190MT UP Z195MT UP Z200MT UP Z205MT Pm Wp 185 190 195 200 205 Vm V 36 0 36 3 36 6 37 0 37 4
3. Im A 5 14 5 23 5 33 5 41 5 48 Voc V 44 8 45 1 45 4 46 0 46 6 lsc A 5 43 5 55 5 65 5 70 5 75 Maximum System voltage IEC _1000V 1000V 1000V 1000V 1000V Maximum System voltage UL 600V 600V 600V 600V 600V Maximum Reverse Current 15A 15A 15A 15A 15A Black tie ZEP frame cells Modules rating at STC Standard Test Conditions Module type UP Z185MT B UP Z190MT B UP Z195MT B UP Z200MT B UP Z205MT B Pn Wp 185 190 195 200 205 Vm V 36 4 36 6 36 8 37 37 2 Im A 5 08 5 19 5 30 5 41 5 51 Voc V 45 0 45 3 45 6 45 9 46 2 lsc A 5 30 5 40 5 50 5 60 5 70 Maximum System voltage IEC 1000V 1000V 1000V 1000V 1000V Maximum System voltage UL 600V 600V 600V 600V 600V Maximum Reverse Current 15A 15A 15A 15A 15A wine 8 60 beds Modules rating at STC Standard Test Conditions Module type UP M240MT UP M245MT UP M250MT UP M255MT UP M260MT Pm Wp 240 245 250 255 260 Vm V 29 6 29 8 30 0 30 2 30 4 Im A 8 10 8 22 8 34 8 44 8 55 Voc V 37 1 37 4 37 7 38 0 38 3 lsc A 8 60 8 70 8 80 8 88 8 96 Maximum System voltage IEC 1000V 1000V 1000V 1000V 1000V Maximum System voltage UL 600V 600V 600V 600V 600V Maximum Reverse Current 15A 15A 15A 15A 15A due cl R e RU celis Modules rating at STC Standard Test Conditions Module type UP M235MT B UP M240MT B UP M245MT B UP M250MT B UP M255MT B Pm Wp 235 240 245 250 255 Vm V 29 8 30 0 30 2 30 3 30 5 Im A 7 88 8 00 8 12 8 24 8 36 Voc V 37 1 37 4 37 7 38 0 38 3 lsc A 8 40 8
4. Upsoler Delivering safe solar Photovoltaic Module Safety amp Installation Manual Version 1 19 English NOTICE Please carefully read and understand the provided installation manual before installing wiring or operating our product in your PV system Failure to follow all proceeding terms and conditions will void Upsolar s Limited Warranty contract 1 0 INTRODUCTION Thank you for choosing the Upsolar Photovoltaic module Our goal is to provide you with a top quality long lasting product This installation guide provided by Upsolar Co Ltd and supplied with Upsolar modules contains information regarding proper handling installation and maintenance All instruction in this guide should be read and understood by all parties before attempting to install Upsolar photovoltaic modules PV designers and installers should always comply with all safety precautions listed within this guide as well as any local or jurisdictional codes that pertain to PV installations Upsolar reserves the right to make changes to both products and installation manual without prior notice to the customer Please contact support upsolar com for any additional questions or explanations 1 1 Liability Condition The installation techniques handling and use of Upsolar product are beyond Upsolars company control Therefore Upsolar does not assume responsibility for loss damage or expense resulting from improper installation handling or use 1
5. 2 Frame Holes for open rack systems Attach the PV module to the mounting system using the provided factory mounting holes At least 4 points of connection are required between each module and the mounting surface t is recommended that 4 M6 1 4 SS bolts with nuts and washers are used on each module The torque recommended to fix the bolts is 15 N m 11 1 Ib ft 3 End Mount for open rack and roof installations End mounting is the capture mounting of the length of the module s end frame to a supporting rail The end frames are on the shorter sides of the module The end mounting rail and clips or clamps must be of sufficient strength to allow for maximum design pressure of the module Verify this capacity with the mounting system vendor before installation Slope PV module has class C fire rating and must be installed over a roof with appropriate fire resistance A minimum slope of 5 ft for installation is required to maintain fire class rating Further consult local regional and national building fire statutory regulation p d NDRAINAGE HOLE JucrioNBOx J w Ua ol N LABEL le y zd FRAMI NTING T PRAMESLE Menom HOLES A E emm y o 2 TOP CLAMPICLIP MOUNTING LOCATIONS LENGTH4 L4 o p ia Laud are iw mI Figure 1 Module Mounting Location www upsolar com
6. Maximum System voltage IEC 1000V 1000V 1000V 1000V 1000V Maximum System voltage UL 600V 600V 600V 600V 600V Maximum Reverse Current 20A 20A 20A 20A 20A ka GaS TACENS Modules rating at STC Standard Test Conditions Module type UP M285P B UP M290P B UP M295P B UP M300P B UP M305P B Pm Wp 285 290 295 300 305 Vm V 35 6 35 7 35 9 36 1 36 3 Im A 8 01 8 12 8 22 8 31 8 40 Voc V 45 0 45 1 45 2 45 3 45 4 Isc A 8 39 8 47 8 55 8 63 8 71 Maximum System voltage IEC 1000V 1000V 1000V 1000V 1000V Maximum System voltage UL 600V 600V 600V 600V 600V Maximum Reverse Current 20A 20A 20A 20A 20A PV modules with Tigo DC maximizer pora idi a te eal Modules rating at STC Standard Test Conditions Module type UP M185MT UP M190MT UP M195MT UP M200MT UP M205MT Pm Wp 185 190 195 200 205 Vm V 36 0 36 3 36 6 37 0 37 4 Im A 5 14 5 23 5 33 5 41 5 48 Voc V 44 8 45 1 45 4 46 0 46 6 Isc A 5 43 5 55 5 65 5 70 5 75 Maximum System voltage IEC _ 1000V 1000V 1000V 1000V 1000V Maximum System voltage UL 600V 600V 600V 600V 600V Maximum Reverse Current 15A 15A 15A 15A 15A Bue e qerelis Modules rating at STC Standard Test Conditions Module type UP M185MT B UP M190MT B UP M195MT B UP M200MT B UP M205MT B Pm Wp 185 190 195 200 205 Vm V 36 4 36 6 36 8 37 37 2 Im A 5 08 5 19 5 30 5 41 5 51 Voc V 45 0 45 3 45 6 45 9 46 2 lsc A 5 30 5 40 5 50 5 60 5 70 Maximum System voltage IEC 1000V 1000V 1000V 1000V 1000V Maximum System voltage UL
7. UL 600V 600V 600V 600V 600V Maximum Reverse Current 15A 15A 15A 15A 15A wipe O a cels Modules rating at STC Standard Test Conditions Module type UP M285PT UP M290PT UP M295PT UP M300PT UP M305PT Pm Wp 285 290 295 300 305 Vm V 35 4 35 5 35 7 35 9 36 1 Im A 8 06 8 17 8 26 8 36 8 45 Voc V 45 0 45 2 45 4 45 6 45 8 Isc A 8 42 8 50 8 58 8 66 8 74 Maximum System voltage IEC 1000V 1000V 1000V 1000V 1000V Maximum System voltage UL 600V 600V 600V 600V 600V Maximum Reverse Current 15A 15A 15A 15A 15A Be isis Modules rating at STC Standard Test Conditions Module type UP M285PT B UP M290PT B UP M295PT B UP M300PT B UP M305PT B Pm Wp 285 290 295 300 305 Vm V 35 6 35 7 35 9 36 1 36 3 Im A 8 01 8 12 8 22 8 31 8 40 Voc V 45 0 45 1 45 2 45 3 45 4 Isc A 8 39 8 47 8 55 8 63 8 71 Maximum System voltage IEC _ 1000V 1000V 1000V 1000V 1000V Maximum System voltage UL 600V 600V 600V 600V 600V Maximum Reverse Current 15A 15A 15A 15A 15A www upsolar com Upsoler Delivering safe solar PV modules with Solaredge Power optimizer Mr anata cells Modules rating at STC Standard Test Conditions Module type UP M185MS UP M190MS UP M195MS UP M200MS UP M205MS Pm Wp 185 190 195 200 205 Vm V
8. Upsoler Delivering safe solar Module Frame M68 Fiat Washer SS Spring Nut Mounting Rail Frame Hole Mount Module Ground back view igure 2 Module installation diagram recommended 6 2 PV modules handling 10 11 12 Do not expose to the PV module to excessive load on the surface or bend the frame DANGER Risk of breaking Glass Do not stand or step on the PV module The glass may be slippery DANGER Risk of injury and electric shock if glass is broken PV modules are heavy Please handle with care It is recommended for two qualified personal to handle one PV module at a time Do not hit or put excessive load on the glass or back sheet PV cells may break Do not twist the interconnect cable excessively NEVER expose cables wires or other electrical parts to water DANGER risk of electric shock Do not drill holes in the frame Modifications void the PV Module warranty Do not touch the PV Module with bare hands The frame of the PV Module has sharp edges and may cause injury Wear suitable gloves when handling the PV Module Do not drop the PV Module or allow objects to fall on the PV module The packaging is not resistant to weathering Do store PV modules in a dry place and NEVER expose directly to water eg Rain Transport the PV Modules to the installation site in the original packaging Protect the module cables from mechanical stress during transport and handling ATTEN
9. 36 0 36 3 36 6 37 0 37 4 Im A 5 14 5 23 5 33 5 41 5 48 Voc V 44 8 45 1 45 4 46 0 46 6 Isc A 5 43 5 55 5 65 5 70 5 75 Maximum System voltage IEC 1000V 1000V 1000V 1000V 1000V Maximum System voltage UL 600V 600V 600V 600V 600V Maximum Reverse Current 15A 15A 15A 15A 15A a Ed arate cells Modules rating at STC Standard Test Conditions Module type UP M185MS B UP M190MS B UP M195MS B UP M200MS B UP M205MS B Pm Wp 185 190 195 200 205 Vm V 36 4 36 6 36 8 37 37 2 Im A 5 08 5 19 5 30 5 41 5 51 Voc V 45 0 45 3 45 6 45 9 46 2 Isc A 5 30 5 40 5 50 5 60 5 70 Maximum System voltage IEC 1000V 1000V 1000V 1000V 1000V Maximum System voltage UL 600V 600V 600V 600V 600V Maximum Reverse Current 15A 15A 15A 15A 15A EL Sa ids bia Modules rating at STC Standard Test Conditions Module type UP S185MS UP S190MS UP S195MS UP S200MS UP S205MS Pm Wp 185 190 195 200 205 Vm V 36 0 36 3 36 6 37 0 37 4 Im A 5 14 5 23 5 33 5 41 5 48 Voc V 44 8 45 1 45 4 46 0 46 6 Isc A 5 43 5 55 5 65 5 70 5 75 Maximum System voltage IEC 1000V 1000V 1000V 1000V 1000V Maximum System voltage UL 600V 600V 600V 600V 600V Maximum Reverse Current 15A 15A 15A 15A 15A Black toe eo ki ais LI Modules rating at STC Standard Test Conditions Module type UP S185MS B UP S190MS B UP S195MS B UP S200MS B UP S205MS B Pm Wp 185 190 195 200 205 Vm V 36 4 36 6 36 8 37 37 2 Im A 5 08 5 19 5 30 5 41 5 51 Voc V 45 0 45 3 45 6 45 9 46 2 Is
10. 50 8 60 8 70 8 80 Maximum System voltage IEC _ 1000V 1000V 1000V 1000V 1000V Maximum System voltage UL 600V 600V 600V 600V 600V Maximum Reverse Current 15A 15A 15A 15A 15A www upsolar com Upsolar Delivering safe solar Monocrystalline 6 60 cells White type ZEP frame Modules rating at STC Standard Test Conditions Module type UP Z240MT UP Z245MT UP Z250MT UP Z255MT UP Z260MT Pm Wp 240 245 250 255 260 Vm V 29 6 29 8 30 0 30 2 30 4 Im A 8 10 8 22 8 34 8 44 8 55 Voc V 37 1 37 4 37 7 38 0 38 3 Isc A 8 60 8 70 8 80 8 88 8 96 Maximum System voltage IEC _1000V 1000V 1000V 1000V 1000V Maximum System voltage UL 600V 600V 600V 600V 600V Maximum Reverse Current 15A 15A 15A 15A 15A Black tie ZEP frame cells Modules rating at STC Standard Test Conditions Module type UP Z235MT B UP Z240MT B UP Z245MT B UP Z250MT B UP Z255MT B Pm Wp 235 240 245 250 255 Vm V 29 8 30 0 30 2 30 3 30 5 Im A 7 88 8 00 8 12 8 24 8 36 Voc V 37 1 37 4 37 7 38 0 38 3 Isc A 8 40 8 50 8 60 8 70 8 80 Maximum System voltage IEC 1000V 1000V 1000V 1000V 1000V Maximum System voltage UL 600V 600V 600V 600V 600V Maximum Reverse Current 15A 15A 15A 15A 15A seus 7 oe Modules rating
11. ELECTRICAL CHARACTERISTICS OF A PV MODULE It is very important to understand that a photovoltaic module can have electrical characteristics different than the Standard Test Conditions STC rating on the module nameplate Atmospheric conditions often increase the module s current and or voltage higher than that reported at STC STC 1000 W m AM 1 5 25C Always refer to your local jurisdictional codes when sizing conductors fuses inverters and other Balance of System BOS components amp WARNING All installation and mounting instructions must be read and properly understood before attempting to install wire and or operate PV modules PV modules generate DC electricity when exposed to light This can pose danger to the installer user and or property Any contact with electrically active module terminals can result in arcing leading to shocks burns fires and or death PV modules are electrically live when mounted and installed Danger Electrical potential SHOCK DANGER increases with parallel higher currents and series higher voltage connection of PV modules The PV installer must assume all inherent risk of property damage and or personal injury related to the mishandling of PV modules during installation and maintenance Under normal conditions a photovoltaic module is likely to experience conditions that produce more current and or voltage than reported at standard test conditions Accordingly the values
12. at STC Standard Test Conditions Module type UP M210PT UP M215PT UP M220PT UP M225PT UP M230PT Pm Wp 210 215 220 225 230 Vm V 26 8 27 2 274 27 6 27 8 Im A 7 84 7 91 8 03 8 15 8 27 Voc V 33 3 33 4 33 5 33 6 33 7 Isc A 8 40 8 47 8 54 8 61 8 68 Maximum System voltage IEC 1000V 1000V 1000V 1000V 1000V Maximum System voltage UL 600V 600V 600V 600V 600V Maximum Reverse Current 15A 15A 15A 15A 15A pre Ft dicor Modules rating at STC Standard Test Conditions Module type UP M210PT B UP M215PT B UP M220PT B UP M225PT B UP M230PT B Pm Wp 210 215 220 225 230 Vin V 27 0 274 27 6 27 8 28 0 Im A 7 79 7 85 7 97 8 09 8 21 Voc V 33 5 33 6 33 7 33 8 33 9 Isc A 8 35 8 42 8 49 8 56 8 63 Maximum System voltage IEC 1000V 1000V 1000V 1000V 1000V Maximum System voltage UL 600V 600V 600V 600V 600V Maximum Reverse Current 15A 15A 15A 15A 15A Wie S eles Modules rating at STC Standard Test Conditions Module type UP M230PT UP M235PT UP M240PT UP M245PT UP M250PT Pm Wp 230 235 240 245 250 Vm V 29 7 30 0 30 2 30 4 30 6 Im A 7 75 7 84 7 95 8 06 8 17 Voc V 37 2 37 4 37 6 37 8 38 0 Isc A 8 30 8 35 8 40 8 45 8 50 Maximum System voltage IEC 1000V 1000V 1000V 1000V 1000V Maximum System voltage UL 600V 600V 600V 600V 600V Maximum Reverse Current 15A 15A 15A 15A 15A www upsolar com Upsolar Delivering safe solar Polycrystalline 6 60 cells Modules rating at STC Standard
13. e Itis recommended that at least 5 cm or 2 inches is maintained between the mounting surface and the PV module e 2 3 16 inch or 5 mm gap is recommended between adjoining modules to allow for thermal expansion 5 2 PV Module Design Strength Upsolar PV modules have been tested according to IEC design qualification type EN 61215 2005 and IEC safety standard EN 61730 1 amp 2 2007 Application class A refer to clause 12 1 Modules rated for use in the application class A may be used in systems operating at greater than 50 V DC or 240 W where general contact access is anticipated Modules qualified for safety through this part of IEC 61730 and IEC 61730 2 and within this application class are considered to meet the requirements for safety class II Upsolar PV modules have passed the mechanical load test to 5400 Pa This corresponds to a wind speed of approximately 250 mph Upsolar PV modules comply with the test requirements for UL 790 Class C Spread of Flame Test and Burning Brand Test 5 3 Mounting Hardware All hardware that comes into contact with the PV module frame should be corrosion and UV resistant Damage to the module frame or structure could occur if improper materials are used Stainless Steel M6 1 4 Nuts Bolts Washers To minimize galvanic corrosion similar metals to aluminum should be used when in contact with the PV module frame Upsolar Module Frame material Aluminum Always apply proper torque setting
14. on hot modules Make sure all maintenance work is executed by qualified personnel only www upsolar com Upsoler Delivering safe solar 8 0 PV MODULES ELECTRICAL DATA PV modules with standard frames and standard junction box Wiese S Sr races Modules rating at STC Standard Test Conditions Module type UP M185M UP M190M UP M195M UP M200M UP M205M Pn Wp 185 190 195 200 205 Vm V 36 0 36 3 36 6 37 0 37 4 Im A 5 14 5 23 5 33 5 41 5 48 Voc V 44 8 45 1 45 4 46 0 46 6 lsc A 5 43 5 55 5 65 5 70 5 75 Maximum System voltage IEC 1000V 1000V 1000V 1000V 1000V Maximum System voltage UL 600V 600V 600V 600V 600V Maximum Reverse Current 15A 15A 15A 15A 15A Bem 3 2 cels Modules rating at STC Standard Test Conditions Module type UP M185M B UP M190M B UP M195M B UP M200M B UP M205M B Pn Wp 185 190 195 200 205 Vm V 36 4 36 6 36 8 37 37 2 Im A 5 08 5 19 5 30 5 41 5 51 Voc V 45 0 45 3 45 6 45 9 46 2 lsc A 5 30 5 40 5 50 5 60 5 70 Maximum System voltage IEC _1000V 1000V 1000V 1000V 1000V Maximum System voltage UL 600V 600V 600V 600V 600V Maximum Reverse Current 15A 15A 15A 15A 15A wit S eal Modules rating at STC Standard Test Conditions Module type UP M240M UP M245M UP M250M UP
15. rating at STC Standard Test Conditions Module type UP M240MS UP M245MS UP M250MS UP M255MS UP M260MS Pm Wp 240 245 250 255 260 Vm V 29 6 29 8 30 0 30 2 30 4 Im A 8 10 8 22 8 34 8 44 8 55 Voc V 37 1 37 4 37 7 38 0 38 3 Isc A 8 60 8 70 8 80 8 88 8 96 Maximum System voltage IEC 1000V 1000V 1000V 1000V 1000V Maximum System voltage UL 600V 600V 600V 600V 600V Maximum Reverse Current 20A 20A 20A 20A 20A BE Mu eal cels Modules rating at STC Standard Test Conditions Module type UP M235MS B UP M240MS B UP M245MS B UP M250MS B UP M255MS B Pm Wp 235 240 245 250 255 Vm V 29 8 30 0 30 2 30 3 30 5 Im A 7 88 8 00 8 12 8 24 8 36 Voc V 37 1 37 4 37 7 38 0 38 3 lsc A 8 40 8 50 8 60 8 70 8 80 Maximum System voltage IEC 1000V 1000V 1000V 1000V 1000V Maximum System voltage UL 600V 600V 600V 600V 600V Maximum Reverse Current 20A 20A 20A 20A 20A White tige ZEP frame cels Modules rating at STC Standard Test Conditions Module type UP Z240MS UP Z245MS UP Z250MS UP Z255MS UP Z260MS Pm Wp 240 245 250 255 260 Vm V 29 6 29 8 30 0 30 2 30 4 Im A 8 10 8 22 8 34 8 44 8 55 Voc V 37 1 37 4 37 7 38 0 38 3 lsc A 8 60 8 70 8 80 8 88 8 96 Maximum System voltage IEC 1000V 1000V 1000V 1000V 1000V Maximum System voltage UL 600V 600V 600V 600V 600V Maximum Reverse Current 20A 20A 20A 20A 20A Black ipe ZEP frame celis Modules rating at STC Standard Test Conditions Module type UP Z235MS B UP Z240MS B UP Z245
16. the DC side of the PV system are recommended If no lightning protection exists all PV modules should be earth grounded 4 5 Overcurrent Protection OCPD When the potential reverse current of a PV string exceeds the rated Upsolar PV module series fuse rating values indicated in part 8 0 PV modules electrical data an overcurrent protection device OCPD must be used IEC 61730 1 clause 12 3 1 or 2 strings of PV modules in parallel do not require OCPD s but 3 or more PV strings in parallel will usually require an OCPD In this case it is recommended to use one fuse per string rated at 1 56 x Isc or higher Isc is the PV module short circuit current at STC Example of fuse types DCM 600Vdc for UL or PV Fuse 1000Vdc for IEC Each Upsolar module is equipped with 3 by pass diodes Schottky type connected in parallel of the strings of cells to limit the cells heating in case of shading hot spot effect The characteristics of these diodes are Voltage rating Vrem 45 V Current rating lr 15 A 5 0 MODULE CHARACTERISTICS 5 1 Operating Temperature modules especially in hot environments Cells performance will Always try to provide adequate ventilation around installed PV be affected by temperature Predetermined Nominal Temperatures for Upsolar Modules Maximum Operating Temperature 90 C 194 F Minimum Operating Temperature 40 C 40 F Table 1 UPSOLAR MODULE OPERATING TEMPERATURES
17. 2 Limited Warranty All Upsolar PV module warranties are listed in the Upsolar warranty conditions which can be downloaded from our website www upsolar com 2 0 SAFETY PRECAUTIONS Before installing or operating modules please read A and understand all general safety instructions in this manual Module Installation should only be carried out by qualified individuals Always follow and observe all appropriate regional and jurisdictional electric codes Always use properly insulated and or rated electrical and mechanical tools during installation of PV modules Always mount PV modules over a fire resistant roof in case of roof mounting according to IEC 61730 1 clause 12 4 Always ground all PV modules according to the local electrical codes Always use only the same type of PV modules within 1 PV circuit Do not step on or put heavy sharp objects on PV module Do not disconnect module under load Do not use artificial methods for cooling the PV module water Do not touch PV module terminals avoid wearing metallic jewelry or devices attached to the body during installation Do not install PV modules in wet or windy conditions Do not drill extra holes in module frame or glass surface Do not store or install PV modules near flammable gasses or materials Do not disassemble any part of the PV module Do not expose the artificially concentrated sunlight to a module or panel according to IEC 61730 1 clause 12 5 3 0
18. 20A 20A 20A 20A 20A www upsolar com Upsolar Delivering safe solar Black Qype ZEP ro gas Modules rating at STC Standard Test Conditions Module type UP Z230PS B UP Z235PS B UP Z240PS B UP Z245PS B UP Z250PS B Pm Wp 230 235 240 245 250 Vm V 29 9 30 2 30 4 30 6 30 9 Im A 7 70 7 79 7 89 8 00 8 10 Voc V 37 4 37 6 37 8 38 0 38 2 Isc A 8 25 8 30 8 35 8 40 8 45 Maximum System voltage IEC 1000V 1000V 1000V 1000V 1000V Maximum System voltage UL 600V 600V 600V 600V 600V Maximum Reverse Current 20A 20A 20A 20A 20A E Brsgepus Modules rating at STC Standard Test Conditions Module type UP M285PS UP M290PS UP M295PS UP M300PS UP M305PS Pm Wp 285 290 295 300 305 Vm V 35 4 35 5 35 7 35 9 36 1 Im A 8 06 8 17 8 26 8 36 8 45 Voc V 45 0 45 2 45 4 45 6 45 8 Isc A 8 42 8 50 8 58 8 66 8 74 Maximum System voltage IEC 1000V 1000V 1000V 1000V 1000V Maximum System voltage UL 600V 600V 600V 600V 600V Maximum Reverse Current 20A 20A 20A 20A 20A Bk 6 72 cells Modules rating at STC Standard Test Conditions Module type UP M285PS B UP M290PS B UP M295PS B UP M300PS B UP M305PS B Pm Wp 285 290 295 300 305 Vm V 35 6 35 7 35 9 36 1 36 3 Im A 8 01 8 12 8 22 8 31 8 40 Voc V 45 0 45 1 45 2 45 3 45 4 Isc A 8 39 8 47 8 55 8 63 8 71 Maximum System volta
19. M255M UP M260M Pm Wp 240 245 250 255 260 Vm V 29 6 29 8 30 0 30 2 30 4 Im A 8 10 8 22 8 34 8 44 8 55 Voc V 37 1 37 4 37 7 38 0 38 3 Isc A 8 60 8 70 8 80 8 88 8 96 Maximum System voltage IEC 1000V 1000V 1000V 1000V 1000V Maximum System voltage UL 600V 600V 600V 600V 600V Maximum Reverse Current 20A 20A 20A 20A 20A uni inq line Modules rating at STC Standard Test Conditions Module type UP M235M B UP M240M B UP M245M B UP M250M B UP M255M B Pm Wp 235 240 245 250 255 Vm V 29 8 30 0 30 2 30 3 30 5 Im A 7 88 8 00 8 12 8 24 8 36 Voc V 37 1 374 37 7 38 0 38 3 lsc A 8 40 8 50 8 60 8 70 8 80 Maximum System voltage IEC _ 1000V 1000V 1000V 1000V 1000V Maximum System voltage UL 600V 600V 600V 600V 600V Maximum Reverse Current 20A 20A 20A 20A 20A Wien TP pel Modules rating at STC Standard Test Conditions Module type UP M290M UP M295M UP M300M UP M305M UP M310M Pm Wp 290 295 300 305 310 Vm V 35 6 35 8 36 0 36 2 36 4 Im A 8 15 8 24 8 34 8 43 8 52 Voc V 44 6 44 9 45 2 45 5 45 8 lsc A 8 64 8 72 8 80 8 88 8 96 Maximum System voltage IEC 1000V 1000V 1000V 1000V 1000V Maximum System voltage UL 600V 600V 600V 600V 600V Maximum Reverse Current 20A 20A 20A 20A 20A www upsolar com Upsolar Delivering safe solar Monocrystalline 6 72 cells Modules rating at STC Standard Test Conditions
20. MS B UP Z250MS B UP Z255MS B Pm Wp 235 240 245 250 255 Vm V 29 8 30 0 30 2 30 3 30 5 Im A 7 88 8 00 8 12 8 24 8 36 Voc V 37 1 37 4 37 7 38 0 38 3 lsc A 8 40 8 50 8 60 8 70 8 80 Maximum System voltage IEC 1000V 1000V 1000V 1000V 1000V Maximum System voltage UL 600V 600V 600V 600V 600V Maximum Reverse Current 20A 20A 20A 20A 20A www upsolar com Upsolar Delivering safe solar Polycrystalline 6 54 cells Modules rating at STC Standard Test Conditions White type Module type UP M210PS UP M215PS UP M220PS UP M225PS UP M230PS Pm Wp 210 215 220 225 230 Vin V 26 8 27 2 274 27 6 27 8 Im A 7 84 7 91 8 03 8 15 8 27 Voc V 33 3 33 4 33 5 33 6 33 7 lsc A 8 40 8 47 8 54 8 61 8 68 Maximum System voltage IEC 1000V 1000V 1000V 1000V 1000V Maximum System voltage UL 600V 600V 600V 600V 600V Maximum Reverse Current 20A 20A 20A 20A 20A Sa ed 6e SECES Modules rating at STC Standard Test Conditions Module type UP M210PS B UP M215PS B UP M220PS B UP M225PS B UP M230PS B Pm Wp 210 215 220 225 230 Vm V 27 0 27 4 27 6 27 8 28 0 Im A 7 79 7 85 7 97 8 09 8 21 Voc V 33 5 33 6 33 7 33 8 33 9 Isc A 8 35 8 42 8 49 8 56 8 63 Maximum System voltage IEC _1000V 1000V 1000
21. TION Never pull on cables Handle modules with care when lifting them from pallets Never stack pallets and stack a maximum of 23 modules per pallet only use appropriate Upsolar plastic corners when stacking PV Modules 13 Check the PV modules for damage after unpacking 14 Do not install damaged PV Modules When in doubt about the condition of a PV module please contact Upsolar customer service for advice 15 Always wear protective head gear insulating gloves and safety shoes with rubber soles when installing PV modules 7 0 MAINTENANCE Annual inspection of the PV modules array and BOS is highly recommended The following items regarding the PV modules should be checked periodically to keep the PV system functioning correctly for many years Ensure there is no corrosion on any mechanical connection between the PV module and the mounting structure Tighten all loose components to specified torque settings Check all electrical connection for corrosion and separation on PV modules connectors cables and grounds Never disconnect PV modules under load Make sure PV modules are clean and free of dirt and dust Use water and a soft sponge or cloth for cleaning A mild non abrasive cleaning agent can be used if necessary Critical Cleaning Liquid Detergent is recommended Do not use dishwasher detergent Use water pressure of 45 PSI 3 bar or less De ionized water is recommended if available Do not use cold water
22. Test Conditions Black type Module type UP M230PT B UP M235PT B UP M240PT B UP M245PT B UP M250PT B Pm Wp 230 235 240 245 250 Vm V 29 9 30 2 304 30 6 30 9 Im A 7 70 7 79 7 89 8 00 8 10 Voc V 37 4 37 6 37 8 38 0 38 2 Isc A 8 25 8 30 8 35 8 40 8 45 Maximum System voltage IEC 1000V 1000V 1000V 1000V 1000V Maximum System voltage UL 600V 600V 600V 600V 600V Maximum Reverse Current 15A 15A 15A 15A 15A Whe AER ne uaa Modules rating at STC Standard Test Conditions Module type UP Z230PT UP Z235PT UP Z240PT UP Z245PT UP Z250PT Pin Wp 230 235 240 245 250 Vm V 29 7 30 0 30 2 30 4 30 6 Im A 7 75 7 84 7 95 8 06 8 17 Voc V 37 2 374 37 6 37 8 38 0 Isc A 8 30 8 35 8 40 8 45 8 50 Maximum System voltage IEC _ 1000V 1000V 1000V 1000V 1000V Maximum System voltage UL 600V 600V 600V 600V 600V Maximum Reverse Current 15A 15A 15A 15A 15A Black ype ZEP s Modules rating at STC Standard Test Conditions Module type UP Z230PT B UP Z235PT B UP Z240PT B UP Z245PT B UP Z250PT B Pm Wp 230 235 240 245 250 Vm V 29 9 30 2 304 30 6 30 9 Im A 7 70 7 79 7 89 8 00 8 10 Voc V 37 4 37 6 37 8 38 0 38 2 Isc A 8 25 8 30 8 35 8 40 8 45 Maximum System voltage IEC _ 1000V 1000V 1000V 1000V 1000V Maximum System voltage
23. V 1000V 1000V Maximum System voltage UL 600V 600V 600V 600V 600V Maximum Reverse Current 20A 20A 20A 20A 20A White ie 0 60 CRIS Modules rating at STC Standard Test Conditions Module type UP M230PS UP M235PS UP M240PS UP M245PS UP M250PS Pm Wp 230 235 240 245 250 Vin V 29 7 30 0 30 2 30 4 30 6 Im A 7 75 7 84 7 95 8 06 8 17 Voc V 37 2 37 4 37 6 37 8 38 0 Isc A 8 30 8 35 8 40 8 45 8 50 Maximum System voltage IEC 1000V 1000V 1000V 1000V 1000V Maximum System voltage UL 600V 600V 600V 600V 600V Maximum Reverse Current 20A 20A 20A 20A 20A Bed ie 6 et celle Modules rating at STC Standard Test Conditions Module type UP M230PS B UP M235PS B UP M240PS B UP M245PS B UP M250PS B Pm Wp 230 235 240 245 250 Vm V 29 9 30 2 30 4 30 6 30 9 Im A 7 70 7 79 7 89 8 00 8 10 Voc V 37 4 37 6 37 8 38 0 38 2 Isc A 8 25 8 30 8 35 8 40 8 45 Maximum System voltage IEC 1000V 1000V 1000V 1000V 1000V Maximum System voltage UL 600V 600V 600V 600V 600V Maximum Reverse Current 20A 20A 20A 20A 20A White type ZEP anced Modules rating at STC Standard Test Conditions Module type UP Z230PS UP Z235PS UP Z240PS UP Z245PS UP Z250PS Pm Wp 230 235 240 245 250 Vin V 29 7 30 0 30 2 30 4 30 6 Im A 7 75 7 84 7 95 8 06 8 17 Voc V 37 2 374 37 6 37 8 38 0 Isc A 8 30 8 35 8 40 8 45 8 50 Maximum System voltage IEC 1000V 1000V 1000V 1000V 1000V Maximum System voltage UL 600V 600V 600V 600V 600V Maximum Reverse Current
24. c A 5 30 5 40 5 50 5 60 5 70 Maximum System voltage IEC 1000V 1000V 1000V 1000V 1000V Maximum System voltage UL 600V 600V 600V 600V 600V Maximum Reverse Current 15A 15A 15A 15A 15A White type ZEP frame galls Modules rating at STC Standard Test Conditions Module type UP Z185MS UP Z190MS UP Z195MS UP Z200MS UP Z205MS Pm Wp 185 190 195 200 205 Vm V 36 0 36 3 36 6 37 0 37 4 Im A 5 14 5 23 5 33 5 41 5 48 Voc V 44 8 45 1 45 4 46 0 46 6 Isc A 5 43 5 55 5 65 5 70 5 75 Maximum System voltage IEC 1000V 1000V 1000V 1000V 1000V Maximum System voltage UL 600V 600V 600V 600V 600V Maximum Reverse Current 15A 15A 15A 15A 15A www upsolar com Upsolar Delivering safe solar Monocrystalline 5 72 cells Black type ZEP frame Modules rating at STC Standard Test Conditions Module type UP Z185MS B UP Z190MS B UP Z195MS B UP Z200MS B UP Z205MS B Pm Wp 185 190 195 200 205 Vm V 36 4 36 6 36 8 37 37 2 Im A 5 08 5 19 5 30 5 41 5 51 Voc V 45 0 45 3 45 6 45 9 46 2 Isc A 5 30 5 40 5 50 5 60 5 70 Maximum System voltage IEC 1000V 1000V 1000V 1000V 1000V Maximum System voltage UL 600V 600V 600V 600V 600V Maximum Reverse Current 15A 15A 15A 15A 15A wine eat eels Modules
25. ge IEC _1000V 1000V 1000V 1000V 1000V Maximum System voltage UL 600V 600V 600V 600V 600V Maximum Reverse Current 20A 20A 20A 20A 20A NOTE The electrical characteristics are within 10 of the indicated values of Isc Voc and within 3 of Pmax under standard test conditions irradiance of 100 mW cm AM 1 5 spectrum and cell temperature of 25 Further guidance for modules equipped with Tigo maximizer Solaredge power optimizer ZEP systems or Solrif frame modules installation can be found online on Upsolar web page see following link select Special products http www upsolar com uk products Further contact information Upsolar Technical department Upsolar Group Shanghai Silver Centre 19F 1388 North Shaanxi Road 200060 Shanghai China Tel 86 21 6277 5477 Fax 86 21 6277 5664 E mail support upsolar com www upsolar com
26. of ISC and VOC marked on this module should be multiplied by a factor of 1 25 when determining component voltage ratings conductor current ratings fuse sizes and size of controls connected to the PV output Extract from IEC 61730 1 clause 12 7 and UL1703 clause 48 9 Refer to Section 690 8 of the National Electrical Code for an additional multiplying factor of 125 percent 80 percent derating which may be applicable according to UL1703 clause 48 6 4 0 ELECTRICAL CONFIGURATIONS 4 1 General Wiring Configuration Please follow all module specification and jurisdictional laws regarding interconnection of PV modules Photovoltaic modules can be connected in both series and or parallel to attain the desired electrical output Combined source circuits should contain only 1 type of PV module Conductors must meet or exceed the following requirements IEC 61730 1 clause 12 3 Size minimum 4 0 mm 12 AWG for modules connected in series Temperature rating 40T to 90 Type PV wire USE 2 or equivalent 4 2 Maximum Voltage i e series connections The maximum PV system voltage for a circuit should be calculated as the sum of the rated open circuit voltage of the series connected PV modules corrected for the lowest expected ambient temperature Open Circuit Voltage should be used to determine the voltage rating of all other BOS Balance of System components in the system The open voltage of each string mus
27. s to all mounting hardware according to manufactures specifications 5 4 Operating Environments Do not mount or operate Upsolar PV modules in the following environments e Extreme wind Extreme temperature see Table 1 e Corrosive salty acidic or sulfurous environments e Near flammable gasses or materials 6 0 MOUNTING CONFIGURATIONS Always try and select a suitable orientation to maximize the sunlight exposure to the PV module surface Shading can significantly affect the module and string performance in a PV array Sufficient space between the module frames and mounting structure is required to prevent module damage and to reduce high operating temperatures due to poor air circulation 6 1 PV modules mounting techniques Upsolar PV modules can be mounted either vertical or landscape as long as one of the following mounting procedures is followed according to IEC 61730 1 clause 12 4 1 Mounting clamps for open rack and roof installations Attach the PV module to the mounting system using Clamps or Clips from a certified manufacture according to their instructions Clamp and or clips should be spaced at 4 the length or width from the frame ends 5 cm Top mount clamps clips should always be mounted symmetrically See figure 1 Upsolar recommend the following minimum dimensions for each clamp catch length 30 0mm catch width 5 0mm thickness 3 0mm The torque recommended to fix the clamps is 15 N m 11 1 Ib ft
28. t Conditions Module type UP M230P UP M235P UP M240P UP M245P UP M250P Pm Wp 230 235 240 245 250 Vm V 29 7 30 0 30 2 30 4 30 6 Im A 7 75 7 84 7 95 8 06 8 17 Voc V 37 2 37 4 37 6 37 8 38 0 Isc A 8 30 8 35 8 40 8 45 8 50 Maximum System voltage IEC 1000V 1000V 1000V 1000V 1000V Maximum System voltage UL 600V 600V 600V 600V 600V Maximum Reverse Current 20A 20A 20A 20A 20A Bue ics cens Modules rating at STC Standard Test Conditions Module type UP M230P B UP M235P B UP M240P B UP M245P B UP M250P B Pm Wp 230 235 240 245 250 Vm V 29 9 30 2 30 4 30 6 30 9 Im A 7 70 7 79 7 89 8 00 8 10 Voc V 37 4 37 6 37 8 38 0 38 2 Isc A 8 25 8 30 8 35 8 40 8 45 Maximum System voltage IEC 1000V 1000V 1000V 1000V 1000V Maximum System voltage UL 600V 600V 600V 600V 600V Maximum Reverse Current 20A 20A 20A 20A 20A www upsolar com Upsolar Delivering safe solar Polycrystalline 6 72 cells Modules rating at STC Standard Test Conditions White type Module type UP M285P UP M290P UP M295P UP M300P UP M305P Pm Wp 285 290 295 300 305 Vm V 35 4 35 5 35 7 35 9 36 1 Im A 8 06 8 17 8 26 8 36 8 45 Voc V 45 0 45 2 45 4 45 6 45 8 Isc A 8 42 8 50 8 58 8 66 8 74
29. t never exceed the maximum system voltage value defined by the local regulation IEC 61730 1 clause 12 3 Refer to the datasheets for PV modules Temperature Coefficients 4 3 PV Module and Equipment Grounding Va Please refer to the applicable regional and local codes in NE regards to grounding PV modules and other PV system components If PV modules individual grounding is requested by the local legislation Upsolar PV modules should be grounded to the module frame using one of the provided grounding holes Figure 1 Please refer to NEC Article 250 690 41 690 49 and UL Standard 1703 for proper grounding procedures Example according to IEC61730 1 clause 12 3 Remove any anodization or oxidation from the module frame at the grounding lug point of contact Apply a thin coat of anti oxidant film then use a stainless steel M10 screw with serrated screwhead to penetrate the frame anodized layer nut and lock washer to attach an outdoor rated tin plated copper lug Attach an equipment grounding conductor 4mm 12AWG not provided by Upsolar to the installed grounding lug not provided by Upsolar www upsolar com Upsoler Delivering safe solar 4 4 Lightning protection PV systems do not generally increase the risk of buildings being IA struck by lightning If a lightning protection system currently exists on the installation building the PV system should be connected to any lightning protection system Surge arrestors on