SmartBank/SmartBank Automotive owners/installation manual
Contents
1. 031215
2. SmartBank SmartBank Automotive owners installation manual General Description SmartBank and SmartBank Automotive are auto battery combine controllers that monitor two battery banks and by making accurate measurements decide when to parallel them to allow simultaneous charging and when to separate them to prevent cross discharging The two units SmartBank and SmartBank Automotive are identical in features functions and physical form The only differences are the options of the remote panel switch for each unit and the power saving feature which is not incorporated in the Automotive version Unlike conventional split charge systems using diodes or relays SmartBank is not affected by where the charge is coming from nor does it have to be separately controlled by alternator signals manual switches etc There is nothing for you to forget Neither does it suffer from the voltage drop problems of split charge diodes SmartBank automatically controls charging of 2 battery banks no matter which battery bank is being charged Whether it is an alternator solar panel wind generator or AC powered charger SmartBank will take care of it automatically You make sure your charge source is connected to one battery bank SmartBank will take care of the other one totally automatically No more flat engine batteries because you forgot to switch the battery selector over No more uncharged house bank Not only is SmartBank better than a standard split charge
3. erall voltage above the Disconn level The Hold function introduces a time delay immediately following Connect during which SmartBank will not and cannot disconnect the relay no matter what happens to the battery voltage This time period is adjustable from zero adjustment fully counter clockwise through to 90 seconds adjustment fully clockwise It is recommended that this adjustment be disabled if at all possible in your installation or at least turned to the minimum period required to prevent SmartBank cycling at the initial start of charge The Hold function is an extra feature added to SmartBank to enable it to operate satisfactorily in poor installations In a good installation where the batteries battery chargers etc are correctly sized to each other it will be found that the Hold function simply is not required If even after adjustment of the hold function it is found that SmartBank still disconnects then this is because the charge source is simply too small for the overall battery bank size In this case no amount of adjusting or fiddling will achieve anything The charger is simply too small The only course of action is to increase the size of the charge source Calibration Chart Connect Disconn Haold 133 12 9 13 0 45 13 2 13 4 144 60 12 8 15 13 1 13 5 127 C 13 2 13 0 13 6 126 igs o a BATTERY TYPES These are typical figures required for various battery types assuming that the correct ba
4. es appear that SmartBank has disconnected or connected when it should not have done so if the comparison is made to a simple battery voltage measurement This is not the case If measurements are made to actually check whether or not true charging is taking place it will be found that SmartBank is indeed connecting and disconnecting at the correct times A consequence of the dynamically modified voltage set points and delays is that the actual Connect and Disconnect voltage set points are not actually as critical as it may at first appear Hold adjustment The Hold function is somewhat more involved In an installation where the charge source say an alternator is connected to the engine battery and the house domestic bank is deeply discharged it may be the case that upon connection of the two battery banks the deeply discharged house bank will drop the overall battery voltage below the disconn level This of course will force SmartBank to disconnect the two battery banks SmartBank will then detect that the voltage on the engine battery has risen indicating a valid charge source and reconnect the battery banks The house bank may then drop the voltage below the Disconn level again resulting SmartBank cycling between Connect and Disconn This cycling problem could continue for some considerable time until the charge status of the house bank was sufficiently high to enable the alternator to keep the ov
5. hat your house bank loads do not discharge the engine battery All settings are user adjustable INSTALLATION Installation could not be simpler WARNING Incorrect wiring of this unit may cause serious damage to the electronic circuit and or relay that will not be covered by the warranty It is recommended that the relay be sited as close to the batteries as possible Not only does this make the cable installation easier but it also reduces the losses that would otherwise occur when running high battery charge currents through long battery cables WARNING The usual precautions regarding relays in proximity to possibly explosive battery gasses should be taken If in doubt consult a qualified marine auto electrician As all control and indication is by way of the optional remote panel the siting of the main control unit can be made purely on a safety and ease of installation basis WARNING This unit contains sensitive electronic circuitry and the usual precautions should be taken regarding water dirt and oil ingress etc WARNING Incorrect wiring to any of the terminals may cause serious irrepairable damage to the unit that will not be covered by the warranty It is recommended that 1mm cabling be used for the connections to the main terminal block If any of the connections need to be over 3 metres for any reason then it is recommended that all cables be increased to 2mm This is purely to increase the accuracy of the voltage mea
6. iagram for V2DA remote switch Remote Connector VE POSITIVE VE NEGATIVE ir Relay coil connections GND Feri te Chassis Switch B VE Remote Cable supplied B2 VE B1 VE Please note that your relay may look different to the one in the diagram It will be obvious which contacts are the coil contacts and which are the switched contacts If you are Unsure please contact us or the relay supplier if you supplied your own relay Installation note Mounting holes are drilled in the back of the main case These holes have a corresponding clearance on the PCB Screws with a head diameter up to 8mm may be used with safety Use of screws larger than this may cause short circuits on the back of the PCB SmartBank Automotive installation diagram for VXH2 remote switch Remote Connector VE POSITIVE VE NEGATIVE Relay coil connections GND Chassis Remote Switch B VE Black Red Remote Cable eal supplied re B2 VE Yellow B1 VE Please note that your relay may look different to the one in the diagram It will be obvious which contacts are the coil contacts and which are the switched contacts If you are unsure please contact us or the relay supplier if you supplied your own relay Installation note Mounting holes are drilled in the back of the main case These holes have a corresponding clearance on the PCB Screws with a head diameter up t
7. is on permanently Charge source is switched on the unit connects then disconnects almost immediately The unit simply will not connect Green LED flashing Possible problem Faulty connections between C1 or C2 terminals on the connector block and the relay coil Faulty relay SmartBank has successfully detected a CONNECT voltage but the DISCONNECT voltage is set higher than the CONNECT voltage Run through the set up procedure The charge source is connected to the smaller battery bank and the larger bank is deeply discharged This can cause the overall voltage to fall below the disconnect voltage when the banks are connected together Either move the charge source to the larger battery bank or lower the disconnect voltage Alternatively read the section on the Hold function then adjust accordingly DISCONNECT voltage and CONNECT voltage are set too close together Disconnect voltage is set higher than the connect Voltage RED LED will be lit Refer to setting up procedure Charge source is set lower than CONNECT voltage Either increase the charge voltage or decrease the CONNECT voltage No charge source available or faulty charger 10 NOTES FOR PROFESSIONAL INSTALLERS If you are not a professional installer who is au fait with electronics and battery charging regimes do not read this section No advice will be given and no correspondence entered into regarding any information contained within thi
8. n control box housing the electronics and is installed with a relay of your choice to suit your application battery and charger size etc A simple 5 wire connection is required between SmartBank and the relay and GND SmartBank can be mounted anywhere Installers will notice the vastly reduced current consumption and much cooler running temperature of their usual relay choice when using this option 12 24 volt SmartBank detects whether your installation is a 12 or 24 volt system and adjusts itself automatically Remote Additional features only available with the optional remote panel LED status indicators showing STANDBY mode CONNECTED mode and FAULT Manual override switch to manually connect the relay for emergency engine starting How SmartBank II works SmartBank continually monitors both battery banks Should either battery status indicate that a charge source is available determined from a combination of battery voltage and rate of change of battery voltage over a certain period of time SmartBank will connect the batteries together via the relay ensuring that both battery banks are charged This will not happen immediately There will be a short delay while SmartBank II verifies that the charge source is valid Once the charge source is removed or a very heavy load is connected that risks flattening all the batteries in the event that the charge source cannot keep up with the current requirements it will disconnect the banks ensuring t
9. o 8mm may be used with safety Use of screws larger than this may cause short circuits on the back of the PCB SET UP PROCEDURE Decide on your voltage set points If you are unsure of these refer to the Battery Types section for standard set up guidelines Professional installers may have their own preferred settings depending upon the installation Simply set the adjustments to the required set points as shown in the calibration chart at the end of this manual Connect and Disconnect adjustments There are three adjustments in SmartBank labelled Connect Disconn disonnect and Hold Connect and Disconn correspondingly adjust the nominal voltages at which SmartBank will connect and disconnect the battery banks Basically when the battery voltage on either battery rises to the connect voltage SmartBank will connect the batteries together Conversely when the overall battery voltage falls to the disconnect voltage SmartBank will disconnect the battery banks The reality is not quite this simple in that the actual voltages are dynamically altered by SmartBank depending upon how fast the battery voltage rises or falls In addition to this there are delays before connecting or disconnecting which again are dynamically altered by SmartBank depending upon how fast the battery voltage rises or falls This drastically improves the performance of SmartBank over a primitive voltage controlled relay For this reason it may at tim
10. relay or diode set up but it s actually simpler and quicker to install No modifications are required to the existing installation Only additional cabling is required thus ensuring warranties are not affected Remote Panel An optional remote panel is available which connects to SmartBank simply by plugging in an RJ11 type cable supplied with the remote Alternatively SmartBank Automotive can be supplied with a dash mounted switch which can be used for emergency battery paralleling to assist engine starting Integral to this switch is an LED which illuminates to show connected status Power Consumption SmartBank has been designed and built using ultra low power semi conductors and ultra low power design techniques which results in a standby current that is so low no ON OFF switch is required Therefore you can never forget to switch SmartBank on because you never need to switch it off Standby power consumption is less than 0 2 Ah per week Power Save feature SmartBank also uses switch mode technology to control the relay coil and thus keep the power consumption to an absolute minimum whilst in the connected mode typically using less than half the power of an equivalent standard split charge relay This is vital when a small charge source such a solar panel is being relied upon to maintain batteries Please note that this feature is not available in SmartBank Automotive It is disabled as standard SmartBank consists of the mai
11. s section Reduced power consumption In a power critical application it may be desirable to reduce even the very small power consumption of SmartBank by installing an on off switch This can be achieved by fitting a SPST switch in series with R33 on the PCB This will kill all power to the control circuitry and reduce the current consumption of SmartBank from 700uA to around 100uA This switch could be replaced with a relay controlled by other equipment Defeating the power save feature At the time SmartBank connects it send a 350mS full power pulse to the relay coil This ensures that the relay closes fully and quickly SmartBank then reduces the power delivered to the relay coil by pulsed switch mode techniques This has several advantages A It drastically reduces the connected current draw of SmartBank B It vastly increases the operating life of the relay due to reduced coil dissipation most relay failures are due to the coil failing not the contacts C It enables the use of relays which are not continuously rated to be utilised in continuous duty D It enables a 12 volt relay to be used in a 24 volt installation provided that 12 volt relay is rated for continuous duty In some installations it may be advantageous to defeat the power save feature One example being an installation in which it is desired that some external equipment can override SmartBank and disconnect or connect the relay in an AND OR type scenario Disconnec
12. surements The cabling from the batteries to the main relay terminals cannot be specified in this manual as it depends upon the installation and cable lengths etc As a rough guide you should use cable that will have a maximum voltage drop of 0 1 volts at the maximum charge rate in your installation Obviously this depends upon the cable length If in doubt consult a qualified marine auto electrician or cable voltage drop chart In any event a cable capable of handling the maximum charge capability of the installation MUST be used Your cable supplier will be able to advise you on this point Failure to adhere to these instructions could result in overheating of the battery cables SmartBank installation diagram nemo connector Relay coil connections H GND Chassis Huli B VE VE POSITIVE B2 VE VE NEGATIVE B1 VE Flease note that your relay may look different to the one in the diagram It will be obvious which contacts are the coil contacts and which are the switched contacts If you are unsure please contact us or the relay supplier if you supplied your own relay Installation note Mounting holes are drilled in the back of the main case These holes have a corresponding clearance on the PCB Screws with a head diameter up to 8mm may be used with safety Use of screws larger than this may cause short circuits on the back of the PCB SmartBank Automotive installation d
13. ting the feed from SmartBank to the relay coil will disconnect the relay ok but will not always ensure it can be reconnected due to the relay requiring the full power pulse to close correctly For this reason the power save feature can be disabled by soldering across the solder contacts on the PCB as shown in the diagram Note that the power save feature is disabled by default in SmartBank Automotive Battery compartment venting Wet cell batteries give off explosive gases when being charged In many installations natural ventilation is sufficient to vent these gases to the outside world but in others it may be necessary to force vent these using a fan SmartBank is ideal for this additional use by simply using another relay energised by SmartBank to control the fan Obviously a fan and relay suitable for explosive atmospheres must be used 11 Additional relays SmartBank can safely provide power to relays with a total normal coil current consumption of 3 amps note that this will not be the actual current draw due to the power save feature so additional relays can easily be added to parallel say a bow thruster or windlass battery If there is any doubt as to the total coil current consumption then use a small relay energised by SmartBank to control the coil current to the larger relays Component identification aaa Connect Disconn Hold Powersave Cc_ a po ETA E ep R33 FOO REY F SmartBank 12 24
14. ttery charger is being used for the batteries Clearly if the wrong battery charger is being used ie charging at an incorrect voltage for the selected battery type then these voltages will possibly need to be adjusted If in doubt consult a qualified marine auto electrician or contact your dealer Wet cell batteries Connect voltage 13 2v 26 4 on 24 volt systems Disconnect voltage 12 8v 25 6 on 24 volt systems Gel cell batteries Connect voltage 13 4v 26 8 on 24 volt systems Disconnect voltage 12 8v 25 6 on 24 volt systems AGM batteries Connect voltage 13 4v 28 8 on 24 volt systems Disconnect voltage 12 8v 25 6 on 24 volt systems SPECIFICATIONS Connect voltage range 13 0 to 13 6 volts 26 0 to 27 2 volts on 24 volt systems Disconnect voltage 12 6 to 13 3 volts 25 2 to 26 6 volts on 24 volt systems Hold time 0 to 90 seconds Standby current draw lt 0 001 amp lt 0 02 watts with remote lt 0 0004 amp lt 0 005 watts no remote Connected current draw cannot be specified for SmartBank as it depends almost entirely upon the relay used but will typically be between 25 to 50 of the usual coil current consumption for the relay chosen SmartBank never uses more than 0 001 amps for it s own purposes while in standby or 0 008 amps maximum in any other mode Specifications are subject to change without prior notification TROUBLE SHOOTING Symptom Green LED lights up solid but the relay does not energise Red LED
Download Pdf Manuals
Related Search
Related Contents
C-9812 C-9812 Lexmark X548 Series 7525-63x Service Manual VFP-12XD V6.60 Release Notes Manuale d`uso ATTENTION ATTENTION PRÉCAUTIONS PRÉCAUTIONS HRK-7000-7000A deutsch-2008 Untitled - Repositório Científico do Instituto Politécnico do Porto Dynamic Series Catalog PDF 876KB - ヨコモ ドリフトパッケージ オフィシャルサイト Copyright © All rights reserved.