1. As the thermal imager lens had been coated an antireflective film layer and often clean will damage the coating the optical surfaces of the imager lens should only be cleaned when visibly dirty Please avoid touching the exposed lens surface as the acid substance on the print will damage the coatings and lens substrates Use only a proprietary lens cleaning tissue L IR518E Thermal Imager User Manual Chapter 3 IR518E Technical Specifications Detector Type Spectral range Pixel FOV Video output Adjust Display ACIDO adapter Rech Ni MH SES 1 2V 2500mAh X4 battery Operating Temperature Storage Temperature Sine wave 5Hz 200Hz 5Hz accelerated speed Vibration 2 0g duration 6min X axial vibration Half sine wave accelerated speed 25g duration 6ms Shock X axial shock 3times L IRS18E Thermal Imager User Manual Interfaces Analog video output USB port RS232 Physical Characteristics Weight 760g with batteries and SD card Size 182mmx97mmx68mm L IR518E Thermal Imager User Manual Chapter 4 Buttons and interface of imager Buttons IR518E Thermal Imager figure Infrared lens Interface Battery cover Hand strap L IR518E Thermal Imager User Manual The function keyboard is on the top of IR518E XN Buttons Instruction Buttons Function Press 3 sec to power on off the imager POWER Short press to calibrate the imager m
2. Zeng Three operations can be done according to indications shown above 1 Press M to return image playback menu 2 Press to delete one infrared image and then return back to image playback menu 3 Press you will see the picture shown as below 26 L IR518E Thermal Imager User Manual yet eg ET c roppcn ben Jee Ca WI According to the indication press to confirm the delete of all infrared images then return back to playback menu Press M to cancel the delete operation then return to image delete menu The operation of video playback is the same as images 21 User L IR518E Thermal Imager Manual 6 11 Formatting SD card Infrared images and videos can be stored in the built in SD card Choose Format menu then press M to format the SD card Format the 5DCard Exit Confirm Select_ M Enter A According to the indications shown in the picture press to exit the operation Press to format SD card see below picture ss to format Confirm e Select M Enter Format tandby 28 L IR518E Thermal Imager User Manual 6 12 Restore factory setting Choose Default then press M the below picture will shown on the screen Factory Setting Exit Confirm oO According to the indications press to cancel the operation Press to restore factory setting
3. freeze infrared image and save it into the built in SD card there is indication of the file name on the upper left side of the screen After saving the thermal imager will return to the real time infrared image status cy PG0020 bmp 23 L IR518E Thermal Imager User Manual 6 9 2 Take and save the infrared video When no menu displays long press to take infrared video and save it in the built in SD card IR518E shows the recording time that left according to the memory space 00 05 728 44 6 AE By A T AN h Wi In the above picture the file name recording time and left recording time are displayed Long press to stop the video taking 24 L IR518E Thermal Imager User Manual 6 10 Infrared image and video playback Choose Replay then press M to enter the below interface Im a O P0028 bmp 16716 oO According to the indications press to browse infrared images press M to enter the interface that shown below 25 L IR518E Thermal Imager User Manual menial gem O ppppon pup eeng e EN eye i E Return M Exit 4 Delete Return Exit Three operations can be done according to the indications shown in the above picture 1 Press M to exit playback menu and back to live infrared image 2 Press to return image playback menu 3 Press to enter image delete menu deg Fam Oppen bmp
4. the brightness contrast Auto SemiAuto adjustment ways Brightness Contrast Auto offset and gain Brightness Contrast Auto offset manual gain In the above table brightness is the expect value of the average of the actual value of the whole or part of the image contrast is the expect value of the actual contrast of the whole or part of the image offset and gain are two parameters related to brightness and contrast in the brightness and contrast calculation 6 7 2 Brightness and contrast adjustment In the automatic mode user can adjust menu item B to get satisfying image brightness and adjust menu item C to get satisfying image contrast System sets offset and gain in real time as per your input to obtain acceptable image quality Parameters of menu item B and C values are shown in percentage In the semiautomatic condition user can adjust menu item B to get satisfying image Brightness System automatically sets offset as per your input brightness value User can adjust gain manually Parameters of menu item B and C values are shown in percentage Notice If user find the contrast is low when using the imager just like below 17 L IR518E Thermal Imager User Manual WAN User can adjust contrast according to the circumstance condition in order to make a satisfying image 18 L IR518E Thermal Imager User Manual 6 7 3 Electronic Zoom The thermal imager can a
5. 29 L IR518E Thermal Imager User Manual 6 13 Transmit the image and video from the thermal imager to PC The method of transmitting the image and video from the thermal imager to PC is the same as the digital camera picture transmitting Connect the thermal imager and PC via the USB cable the PC can identify the removable storage device Double click the GUIDE_IR disc mark to open the storage device there are two folders in the storage device PICTURE and VIDEO and these two folders are respectively stored infrared pictures and videos User can conduct copy cut and delete and etc operations as the normal files After operation please eject the removable storage device GUIDE IR and then pull out the USB cable plug 30 IR518E Thermal Imager User Manual Chapter 7 Battery Status IR518E thermal imager is power supplied by 4 units of replaceable and rechargeable Ni MH AA batteries average operation time is 2 hours The battery should be charged with a battery charger 7 1 Precautions esch Please ensure batteries are fully charged and discharged at the first 3 times 2 Please choose qualified rechargeable batteries The min current should be 2500mAnh 3 The battery charger will not be supplied in standard package and it could be purchased locally 4 Please charge batteries when the ambient temperature is between 0 C to 40 C 5 Do not mix new batteries and old batteries together to
6. Guide Infrared IR518E Monocular Thermal Imager L IR518E Thermal Imager User Manual Content Chapter 1 rege el ee 2 Chapter 2 EECHER 3 Chapter 3 IRSISE Techinical Specifications sescves sssccsaiecsrersneninanadoninveracetaparlsndcenanoeacnnteuisoniesubawsadaniieetnontes 5 Chapter 4 Buttons and interface Of imager eeeeeeessssssssssseeetttrrrrrsssssssssssssseerrererssssssssssseeetereeresssssss 7 Chapter 5 KEEN 9 Di ON EE 9 5 2 QUICk Start UL TEE 11 Chapter 6 EE 13 6 1 POWEF INSUFUCTIONS ICOM EE 13 6 2 Menu Instruction EE 14 yo le An EE 15 6 4 Button instruction setting AA 15 Uy ue Le EE 15 6 6 Crossed hair cursor E 15 6 7 Image adjustment 000 eee eeeceneceneeceaeeesceceaeeeseeceaecesceceaeeseeceaeeseeeseaeeeeeeseaeeesees 17 6 7 1 Auto Semi auto mode setting 02 2200s00ansseceseccceceesuseacsenetuariaqeteacereadceeeestioaaauantsaceesnencatoss 17 In the above table brightness is the expect value of the average of the actual value of the whole or part of the image contrast is the expect value of the actual contrast of the whole or part of the image offset and gain are two parameters related to brightness and contrast in the Driehtoess and contrast Cal CUA OM E 17 6 7 2 Brightoess and contrast adjustment task canctashcnwdierd covsdonisoaciaudcnasdandauiiendiourievieawtasdeancianss 17 G79 PICCHOMIC 7 GOI EN 19 EE A OTN EET E AEE E E E AA AE A E TT 20 EE E A E A E E ET A AT 21 6 8 lee 22 6 9 Freeze and save
7. anually When no menu displayed Press 3 sec to bring out menu Short press to switch between white black hot When menu displayed Press this button to select the menu items When menu displayed Press this button to choose the menu from left to right When no menu displayed Switch between original image and 2X image When menu displayed Press this button to choose the menu from right to left When no menu displayed Short press to take and save infrared image Long press to take and save image video IR518E imager can be used as handheld device or can be stably installed on tripod please see the screw hold on the bottom side of the camera L IR518E Thermal Imager User Manual Chapter 5 Quick start guide 5 1 Preparation 1 The operator could hand hold the IR518E Thermal Imager or fix it on the tripod 2 According to the thermal imager interface definition connect the enclosed video USB cable power cable and 9V power adapter to the display equipment and AC power shown as below picture When Insert the cable plug into the thermal camera socket please aim the convex part to the concave part and slightly insert 9VDC video USB RS232 a SEN 110 240VAC 9VDC PC PC port Adapter USB 110 240VAC Note When the camera connected with the PC by USB port all button operation will be ineffective Thus please do not connect the camera with the PC when observing and only connecting when transmi
8. elp then press M to enter to Help Menu Press to view the helping information Press M again to exit this menu 6 4 Button instruction setting select Note then press M to choose whether the button instruction shall be displayed or not We suggest users to open the button instruction 6 5 Stand by mode You can press button M to enable disable of the standby mode To set Standby as 4 10 15 20min to enable the feature lf under the stand by mode when the IR sensor besides the eye piece detect the human eye the LCD screen will be working when your eye leaves the eye piece after 2 min the screen will shut down and the camera will be power off after 4 min 10 min 15min or 20 min If the stand by mode is off no matter the eye is close or not the LCD screen will always be light 6 6 Crossed hair cursor User can choose the crossed hair cursor Choose Cursor then press M to switch the cursor setting When it s set as 0 there will be no cursor When set as 1 to 3 you will see the following image 15 L IR518E Thermal Imager User Manual Cursor Hot OPP Palette 0 e Select M Adjust 4 k Select M Adjust 4 Hot OFF Palette 0 16 L IR518E Thermal Imager User Manual 6 7 Image adjustment 6 7 1 Auto Semi auto mode setting Choose Auto SemiAuto then press M to switch between Auto and Semi auto mode and correspondingly to select
9. lso conduct electronic zoom function When no menu displays press the to switch the original image and 2 times zooming image 2 times Zooming image Z 2 19 L IR518E Thermal Imager User Manual 6 7 4 Polarity IR518E uses different gray level to indicate different temperature Under positive polarity mode brighter part represents higher temperature While under negative polarity mode brighter part represents lower temperature When no menu displays short press M to switch between 2 polarity modes White Hot id TT e ch 2 lu ld o Black Hot 20 L IR518E Thermal Imager User Manual 6 7 5 Colour palettes Choose Palette then press M to choose from 0 8 5 and you will find 9 different showing accordingly k Select M Enter 4 Cursor 0 Hot OFF Palette gt Palette 0 Select M Enter 4 s Hot OFF Palette 14 Palette 4 21 L IR518E Thermal Imager User Manual Palette 6 6 8 Hot spot tracking Choose Hot then press M set Hot ON the highest temp spot will be shown on the screen 22 IR518E Thermal Imager User Ap al 6 9 Freeze and save the infrared image and video 6 9 1 Freeze and save the infrared image Before taking photo firstly aim to the target and adjust the focus then keep the thermal imager body stable so as to obtain a clear image when no menu displays press to
10. not casually place knock or shock the thermal imager and accessories and make it far off the static to avoid any damages lt Never attempt to disassemble or open the imager body as this action will void the warranty Contact manufacturer for calibration or repair To ensure that the IR518E Thermal Imager is kept in a good working condition and remains fully functional operation the following guidelines should be respected at all times All User Manuals and leaflets should be read thoroughly before proceeding with operation of the equipment please contact us if there is any unclear Keep the IR518E Thermal Imager steady during operation Do not use the IR518E Thermal Imager beyond the specified operation condition scope Do not apply the non fitted thermal imager adapter Do not frequently power on off the imager The time between on and off should be not less than 20 sec Do not pull in out all the cables when the imager is power on and highly recommend to cut off the power of all the connected electric systems when pull in out the cables L IR518E Thermal Imager User Manual Ifthe observation is over or in holding state please timely cut off the power so as to effectively extend the imager lifetime Pay attention to the protection of the various cables and wires that connected with thermal imager Do not clean with chemical solvent diluents The clean soft and dry flannelette is available
11. operate the camera 6 Do not mix batteries of different types together to operate the camera Chapter 8 Trouble Shooting lf the IR518E meets troubles please check the items listed below first if the troubles beyond those ones please contact us as soon as possible Me Trouble Reason Measure The Thermal l No battery or lack of power remove battery and install a fully Imager can not be charged one turned on or there 31 IR518E Thermal Imager User Manual is blue screen Battery bad connection reinstall the battery and tighten the battery cover Switch off the system and reboot it after 20 seconds The image is blurry Adjust focus till image clear e Perform NUC function manually The image is too dark or too bright Adjust brightness and contrast manually or set to auto brightness contrast mode e Display equipment connection problem or video cable No image output connection problems 32 L IRS18E Thermal Imager User Manual IR518E Standard Packing List IR518E Thermal Imager en PowerivideolUSBIRS232 cable AC adapter Input 110 240VAC Output 9VDC 4G SD card NiMH batteries AA Mignon 2700mAh 4 pcs 1 set Certificates Hand strap Soft bag Shoulder strap Equipment case 33
12. r User Manual Chapter 6 System operation 6 1 Power Instructions icon When the thermal imager works with the external power supply a plug mark will present on the right corner of the screen as the below image shown Ee mm mi bal da f A Ah i A we tay gt e When the thermal imager works with the enclosed Li ion battery a battery mark will present in the right corner of the screen as the below image shown The system continuously monitors the power supply voltage If the power is not enough there will be a window jump out to warn the user if user does not take any measures for it the system will automatically shut down after a certain power decrease 13 L IR518E Thermal Imager User Manual 6 2 Menu Instruction After start up press the M button and the menu bar will be presented on the screen as the below image shown The button instruction will be displayed to state the buttons function on the screen and user can operate as the button instruction FF eer r i 8 F Ke ET Le y P my lt e E i he Wik o Y Open Menu iit Sg d k b H Menu as follows will display on the screen Menu 1 Menu 2 Menu 3 Menu 4 UU Press or buttons to adjust the parameters of selected item press M to confirm the select and enter to sub menu 14 L IR518E Thermal Imager User Manual 6 3 Help menu Choose H
13. r to the target and observe 9 Imaging a Rotate the lens until the target can be clearly observed 11 L IR518E Thermal Imager User Manual b Aim the Thermal Imager to the target C The default mode is AUTOMATIC MODE which provides user with a clear image after simply focusing User can also adjust the brightness and contrast to get a qualified satisfying image Adjust the focus manually to get clear image Note When human eye left the eye detector the imager will enter stand by mode when eyes get close to the eye detector the LCD will lighten again The stand by time can be adjustable in the menu as 4 minutes 10 minutes 15minutes and 20 minutes 10 Function Brief Detailed button operation instructions such as Brightness and Contrast adjustment Polarity selection cursor choosing and checking setting language and button instruction parameters save freeze save and playback pictures record and playback infrared video focus adjustment non uniformity calibration and etc functions please refer to OPERATION INSTRUCTIONS in the next section 11 Power off When operation completed firstly put back the lens cover then press and hold the power button till the shut down progress bar on the screen reach its right end After that remove the cables from the sight by holding the lock pin on the cable and pulling it out Do not pull the cable by force otherwise damage may occur 12 L IR518E Thermal Image
14. reach the international military standard Features lt High resolution uncooled FPA technology lt Two version 384X288 and 160X120 are available two lens options 25mm and 50mm are available lt 640X480 LCD screen a Color Palettes are available lt Auto tracking for the high temperature spot lt Able to freeze and save the picture of infrared image lt Able to record the video of infrared image lt The saved infrared image and video can be transmitted to the PC via the USB port lt Adopt the interpolation zoom method to perform the electronic magnification and there are no mosaic appeared It takes good effect on distant observation lt Auto Semi auto brightness and contrast lt Small size light weight and easy operation lt 50Hz frame rate lt gt License free IR518E Thermal Imager User Manual Chapter 2 Precautions and maintenance lt Do not direct the IR518E Thermal Imager at very high intensity radiation sources such as the sun carbon dioxide lasers or arc welders etc lt Do not direct the IR518E Thermal Imager at high temperature target when power on the IR518E Thermal Imager lt When the IR518E Thermal Imager is not in use or is to be transported ensure that the battery is taken out and the unit is stored in the protective carry case lt The IR518EThermal Imager integrates precision optical equipment and static sensitive electronics so please do
15. the infrared image and video 23 6 9 1 Freeze and save the infrared 1Mage cccccccssssssssssseeeecceceeeeeeeeeaeaeesssssseeeeeeceeeeeeeeeeaaas 23 6 9 2 Take and save the mira ared 106 E 24 6 10 Infrared image and video plavback ccc ccccsceceeesseeceesseeeeeesseeeessteeeenes 25 6 11 Formatling SD card EE 28 6 12 Restore factory Setting 29 6 13 Transmit the image and video from the thermal imager tobt 30 Chapter 7 Battery I E 31 LU Precautions rae rere rar Sse a soe gee tee 31 Cheas Tonbe S hone a E 31 IR518E Standard Packing List ccc cccccsssceceeeesssseeceeesssseeeeeessseeceeeessseeeeeeetaaes 33 IR518E Thermal Imager User Manual ee a This manual must not in whole or part be copied photocopied reproduced translated or transmitted to any electronic medium or machine readable form T mW pw Wm jw Wb SW Wm ww SW bw km ms pw Wm jk bk Wm WS pw WW s IR518E Thermal Imager User Manual Chapter 1 Introduction IR518E is of ultra compact lightweight amp unparalleled design low power dissipation more reliable functionality and robust performance IR518E can penetrate through haze smoke rain snow and total darkness to track and aim target which is difficult to be observed by human eyes in both day and night and all weather condition It makes the war field single track clarity for us and meets various demands of high accuracy for night vision identification tracking analysis and etc
16. tting the picture or video The RS232 communication function is reserved L IR518E Thermal Imager User Manual 3 Please use the 1 2VNi MH batteries 4 of them to power on the imager Insert them into the imager as the following picture 4 SD card is inserted into the imager as the following picture 5 Close the battery cover make sure the battery and SD card are accurately inserted 10 L IR518E Thermal Imager User Manual 5 2 Quick start guide 1 After careful checking press power button for 3 sec to power on the imager 2 Starting up image is as following picture Gume R518 PPPP PP Ver GhEN 20120706 3e4 Creating professional infrared imagers 3 Self checking process is shown on the screen POWER ON TEST Dy gt se ge gege gg gg e gg 0 q j FPGA LSW HI gg OR MCU Sg SSSg OK SENSOR eeeeeeeeee OKt HW HU eR mp ss ss wee eee UL M SU VER 20100519 1 8 gg I aM my D lt lt 4 Manually screw the lens until you see the clear image on the screen 5 The imager has IR sensor right beside the eye piece when your eye is near the screen is working when your eye leaves for a certain time stand by time is adjustable in the menu the camera Is under stand by mode 6 The Thermal Imager will do non uniformity calibration automatically 7 Short press power button to calibrate the imager if there is any non uniformity occurs during the operation 8 Aim the thermal image