RAMOS Ultra User Manual

image

Contents

1. General System Date and Time Connectivity Server Integration System Administrator Password Checking User amp Group Management System Maintenance Services and Security System Log Heartbeat Messages Cloud Monitoring Help This page allows enabling creation and changing of the User and Admin password RAMOS ULTRA LLETY Sensors Notification Access Control Settings User amp Group Management User Name Group Name Description Admin Administrator Built in account for administrator User User Built in account for user Cannot remove Current System Time 02 07 2012 15 04 25 Applications Help Login session timeout minutes 60 60 After highlighting the User click on button Properties to modify settings To modify a user s setting first highlight the user by clicking on it and then click the Properties button as shown in the screen shot above 15 WWW contes COM All rights reserved CONTEG 2012 4 Services and Security Active Services Application disabling Services and Security Active Services Nagios Secure Shell Telnet Web Interface HTTP You can enable or disable the Nagios Video Conferencing Secure Shell and Telnet applications running on the unit thus making the unit more secure as shown in the screen capture above Closing or changing ports disabling HTTP and enabling HTTPS O Access Control J Settings Services and Security Active Services Nagios Secure S
2. Help This page allows enabling creation and changing of the User and Admin password Now click on the Add button to add your groups as shown in the screen shot above zn g v CONTEG RAMOS ULTRA Location System Location Current System Time 02 07 2012 13 29 37 Summary LUET Sensors Notification Access Control Settings Applications Help User amp Group Management Setup 5 General D Use d ETOS System Date and Time Group Setup Connectivity Server Integration Group Name System Guest amp System Administrator Descritption Guest of the system Password Checking Object User amp Group Management User Management System Maintenance puce Services and Security Systems System Log Sensors and Maps Heartbeat Messages Notifications Acknowledge Sensors and Notification Cloud Monitoring This page allows enabling creation and changing of the User and Admin password Enter your group name for example we have added a group named System Guest and entered our description Now check the objects within the web interface that this group will be able to Modify and View Then click the Finish button to save your group 13 WWW cones COM All rights reserved CONTEG 6 2012 Cm Se RAMOS to ONT your e ULTRA Location System Location Current System Time 02 07 2012 14 29 45 Summary LETS Sensors Notification Access Control Settings Applications
3. Reload Sensor Interval au Apply secs Syslog Filters 8 2 Syslog filters Syslog filters enable you to customize your syslog window To begin select the Syslog filter tab found on the summary page SF CONTEG RAMOS o complete your netwoi ULTRA Location System Location Current System Time 03 07 2012 17 27 30 Summary Sensors Notification Access Control Settings Applications Help Map Display Sensor Information Last refresh 3 7 2012 17 27 22 Host Name Type Sensor Name Reading Status ee RAMOS ULTRA EX 0A000858 Module RAMOS ULTRA EX 0A000858 Normal Main Module Temperature Temperature Port 1 23 5 C Normal Sensors status will be reloaded in 03 secs System Log 0 messages i System Log will be reloaded in 07 secs sot Number of display items per page Advanced Filter ti Display Log Level Display Log Type Display Notification Display Sensor Type Display Sensor Status Syslog filters are here Reload Syslog Interval 10 secs Once you have clicked the tab you will be able to select your filter results by altering various fields of information contained within syslog filter window 40 WWW contes COM All rights reserved CONTEG 2012 Syslog Filters Humber of display items per page R iia By clicking on the sign a drop Display Log Level Display Log Type down list of options will become Display Motification avai
4. 7 Mapping RO EEE EAEE EE REOR E EAEE EEEE EEEE EA E E E E A E 35 p EE o og AO E E s 35 7 2 Monitoring via the map TO EE dE uocrsescacv cans duca rad CX RES Mike FI Veo duca dua d AE tend Fla RES VUx Vaca Rad IS NU KC a FIR MET eevee end oe VES ER M Eas dM hei 38 8 SRI ea score seen EO TET D TTL 39 Bie NSF uri E E TIDEIm rm 39 MEME S oM Tu M H 40 9 Making my unit visible on the internet cerea arie EP RIS aco ER paxRDEIEF Eo a pam quoa ca ERE Foro dia aec een eed ieee eerie uar PIS Fre DIO OK co PAEUduE dea tad ut 42 10 119mm Tcrc E OW PH 43 3 www conteg com All rights reserved CONTEG 2012 1 Introduction 1 1 What is RAMOS Ultra The RAMOS Ultra integrates the latest technology to push the boundaries of disaster protection Now you can sense and see problems before they lead to business disruptions It is a high speed accurate intelligent monitoring device featuring a completely embedded host and Linux Operating System This gives you everything you need and nothing you don t 1 2 How to use this manual This manual is meant to provide the user with a step by step guide on how to configure and set up their unit It utilizes screen shots in an effort to make things simpler for the user to follow It is split up into sections that form mini tutorials These cove
5. 8 Ethernet Port This RJ45 port is used to connect your unit to the network 9 External ground The EXT GND can be used to external ground the unit 2 Installation 2 1 Setting up the IP address Every unit is shipped with the default IP address of 192 168 0 100 First we will go through the process of changing this IP address to fit your own network configuration Ensure the following items are available to you before starting 1 RJ45 CATS crossover cable with RJ45 male connection 2 A PC with Ethernet card or LAN socket 3 Power socket for the unit to connect to a Connect the unit via the Ethernet port of the unit to your computers LAN or Ethernet port with a CAT5 crossover cable b Open a web browser and type the default IP address and then press enter m Deed 121550100 Q 1923680100 In some cases your computer might not be able to connect to this default IP address In this situation you need to set up your computers routing table to allow access to this See the appendix on how to setup this c On welcome Log in page enter username Admin and default password for Admin is public Change the password to make your unit secure d Next the home page will be displayed It will look similar to this www conteg com All rights reserved CONTEG 2012 g gg amp CONES i Location System Location Current System Time 21 01 2000 18 57 52 Applications Summary Sensors No
6. Critical and we bind this to the SNMP trap we just created and named SNMP Trap 1 d Now you will see the SNMP trap has been added to our notifications page Link Sensor To Action Escalation Host Name Sensor Name Action on Status Action Name L1 2 f f Import notification from file Vybrat soubor Soubor nevybr n Import Export _ Note To remove this trap and make it inactive highlight the notification and click remove You can repeat this process to set up multiple SNMP traps for different sensors or for multiple SNMP servers etc 28 WWW cones COM All rights reserved CONTEG 2012 6 3 E mail This tutorial provides you the information needed to setup an E Mail Notification To get to the starting point of this tutorial e Log in as administrator e Select the Notifications tab e Click Notification Wizard a If you select to set up an E mail notification you will be shown the following page p to complete your networ Location System Location Summary Notification Menu Begin Notification Wizard Action Add Action Link Sensor To Action Options View Notification Log Notification Analyzer Help Please choose a name for your e mail Action Descriptive Action names increase the simplicity of the system Complete the Mail To From and CC fields with correctly formatted e mail addresses The Mail To and From fields are mandatory Multiple recipients may
7. Help User amp Group Management Setup System Date and Time Connectivity Server Integration System Administrator Add Remove Properties _ Password Checking User amp Group Management System Maintenance Services and Security Seshu New group shown here Heartbeat Messages Cloud Monitoring Help This page allows enabling creation and changing of the User and Admin password Now you can see the new group System Guest has been added to our group list as shown in the screen shot above Ks Ej y Lt o complete your n zin ULTRA Location System Location Current System Time 02 07 2012 14 26 20 Summary LETS Sensors Notification Access Control Settings Applications Help User amp Group Management Setup System Date and Time Connectivity System Guest Server Integration System Administrator E M Password Checking User amp Group Management System Maintenance Services and Security System Log testi Minis After highlighting the group click on Cloud Monitoring Help button Properties to modify settings This page allows enabling creation and changing of the User and Admin password Group Name Description If you wish to modify your group settings highlight the group you wish to modify by clicking on it and then click on the Properties button as shown in the screen shot above 3 4 User Setup X eONFEEG RAMGS ULTRA Location System Location Current System Time 02 07 2012 14 40 56 Su
8. P ibli n doba do p ijet odezvy v milisekund ch Minimum ms Maximum ims Pr m r ms C Users tgpraf gt 2 3 Firmware upgrade Ensure you are running the latest firmware You will also need to download the latest firmware from our website www conteg com This tutorial provides you the information needed to upgrade the firmware To get to the starting point of this tutorial e Log in as administrator e Click on the settings tab a SF CONTEG RAMOS to complete your networ ULTRA Location System Location Current System Time 21 01 2000 18 57 52 Applications Notification Access Control Settings jo EEE E Summary Sensors Summary Setting Sensor Information Layout Setting Host Name Type Sensor Name Reading Status Sensor Filters Main Module Virtual Sensors Temperature on RAMOS Mini 235 Normal Temperature Array Temperature Array Port 2 1 24 5 C Normal aor Temperature Array Temperature Array Port 2 2 24 5 C Normal Advanced Filter Temperature Array Temperature Array Port 2 3 24 5 C Normal Display Status Temperature Temperature Port 4 24 5 C Normal Display Sensor Type m Dry contact UU Forts z Display Host Name Dry contact I O Dry contact I O Port 3 4 20 mAmp 4 20 mAmp Port 1 0 1 kPa Normal Sen RAMOS ULTRA EX 0A000858 Module RAMOS ULTRA EX 0A000858 Apply Filter Clear Filter Sensors status will be reloaded in 05 secs System Log 0 messages Q Sel i Reload Sensor I
9. Port 1 25 5 C Normal Sensors status will be reloaded in 09 secs System Log 2 of 10 messages 2012 07 04 09 37 43 Temperature Port 1 is 27 5 C status is Normal 2012 07 04 09 36 56 Temperature Port 1 is 30 0 C status is High Warning Syslog filter settings are shown here Summary Setting Layout Setting Sensor Filters Syslog Filters Number of display items per page 10 Advanced Filter amp Display Log Level v Error 4 Warning v Notices Display Log Type 4 SensorLog 4 Notification Log Display Notification sus Display Sensor Type 7 Temperature Display Sensor Status V Normal v High Warning Reload Syslog Interval 10 secs Apply 9 Making my unit visible on the internet So far the manual has simply covered the basic set up The setup we have just created will allow you to access your unit on a Local Area Network LAN monitor via the web based interface or with SNMP traps However what if you wish to be able to remotely access your unit from anywhere in the world This is possible however the following steps are only an outline guide Your exact setup and configuration will often depend on your network equipment You are going to need access to your router if you are using one and knowledge of whether your IP address is static or dynamic Simple setup a Let simagine that your unit is connected to a router on your network and the following IP addresses are assigned Yo
10. administrator e Select the Notifications tab e Click Notification Wizard a Fromthe list of notification types select SMS and click next You will then be presented with this SMS Action Wizard Enter a name Enter a phone b You can now either add multiple numbers or click next In our case we will click next SMS Action Wizard Action Name ISMS 1 Phone Number List 00420724740147 Phone Number 00420724740147 LAdd Phone Number Dee Phone Number _ EE c Now we will set up the message that will be sent to the phone You will see the following screen SMS Action Wizard SMS Message Message1 Testing Sensor Port 1 on BOARD DESC is now 80 Unit status is now Normal From 192 168 161 237 lt lt Note A macro is a script that returns specific data collected by the unit In our example here the macro will tell the notification to contain the description sensor name the value current sensor reading and the status high low warning etc these macros are common to all sensor notifications 32 www conteg com All rights reserved CONTEG 2012 d You will now see that the SMS message has changed its format to include the Macro script SMS Action Wizard From IP Text Message DESCRIPTION on BOARD DESC is now Macro script included VALUE UNIT status is now STATUS Next we will choose to set up the type of connection This will depend on the type of mod
11. complete your networ ULTRA Location System Location Current System Time 03 07 2012 15 54 01 Summary LETS Sensors Notification Access Control Settings Applications Help Sensor Map Data Centre Sensor Adding Wizard r ii zal Data Centre Online Sensors RAMOS ULTRA EX 0A000858 Main Module Options Help Place links on map Press the Unlock button then drag the Sensor or Sub Map link on to the map More information Left click on Sensor icons to display real time sensor data This wizard will guide you to the rest of the sensors adding process Display a map containing the Sensor Press the sensor Click the Next button to continue description on the left column Click on Next g After clicking next you will be directed to click the Unlock button Lu RAMOS ONTZI to complete your networl ULTRA Location System Location Current System Time 03 07 2012 15 57 18 Summary LETS Sensors Notification Access Control Settings Applications Help Sensor Map Data Centre Map List Sensor Adding Wizard Data Centre Online Sensors RAMOS ULTRA EX 0A000858 Main Module Help Place links on map Press the Unlock button then drag the Sensor or Sub Map link on to the map More information Left click on Sensor icons to display real time sensor data The round circle icons in the upper left represent the Online Sensors All sensor icons are locked by default To move and place t
12. to start upgrade Upgrade status Waiting to upgrade firmware www conteg com All rights reserved CONTEG 2012 f g During the process you will see the following messages CONTEG RAMOS ULTRA Upgrade status Upgrading mega firmware 0 This is the second half of the upgrade process It will take approximately 10 minutes When this is complete the upgrade status will say Complete and the system will reboot automatically During the upgrade process the red LEDs run from left to right continuously The green LEDs show the percentage of the upgrade process The unit will then reboot The process is complete when the LED s are back to their normal status Then press button refresh CONTEG RAMOS ULTRA Firmware Upgrade COMPLETE system is now rebooting It usually take about 3 minutes to finish When the system is ready the Online LEDs are lit corresponding to the sensor ports used Then the Refresh button can be pressed to reload the page manually 3 Multi users and groups setup Log in to the RAMOS Ultra with the Administrator password the default will be public if you have not changed this yet Click on the Settings page then System Administrator then User amp Group Management as shown in the screen shot below Note The following screen shots may appear small and hard to read Please use the zoom feature in your PDF reader program to increase the size of the page to better view these s
13. CONTEG 2012 1 5 Rear panel Eth 10 400 AS Aion zd P Tue s V RS485 Reset EXT GND Mic Out our Qe De ct a OF 77 Ls 7 5V DC amp c Ca mC The rear panel of the unit is home to various ports and connections The functions of these are as follows 1 Reset button The black tact switch button is used to perform the following functions 1 A single press will announce the IP address of the unit This is audible through the internal speaker It also broadcasts the IP address to the IPset program 2 Turns off password checking when accessing the web based interface hold down for 7 seconds 3 To reboot the unit into the firmware upgrade mode hold down for 12 seconds 2 Sensor ports There are 8 RJ45 ports numbered from 1 8 These are for connecting Conteg intelligent sensors to the unit 3 USB port The unit is equipped with one USB 1 1 port This can be used for example to connect a USB GPRS GSM compatible modem a USB WiFi dongle or USB Bluetooth dongle 4 Mic Out This is used to connect an external microphone for voice modem applications 5 Audio in out The in is used to connect an external microphone the output for external speakers 6 RS485 Port Used for Modbus connectivity We support Modbus master or slave 7 Power Connector This is a 7 5V DC plug We recommend you using a 7 0 9 V 2 5 A power supply WWW contes COM All rights reserved CONTEG 2012
14. Click on this button to take a sensor offline Now your page will look something like below after taking the sensor offline g cONFEG RAMOS to complete your net ULTRA Location System Location Current System Time 02 07 2012 16 47 10 Summary LETS Sensors Notification Access Control Settings Applications Help Sensor Settings wie Host N Main Module lame ain u Sensor Ports Expansion Boards _ Save _ Reset Power Meter Virtual Sensors Help 1 2 3 4 5 6 7 8 ie ieee eel ic aa Ae alc Auto Sense E Auto Sense I Auto Sense _ Auto Sense____ El Auto Sense El Auto Sense___ Auto Sense _ Auto Sense _ Auto Sense status and state Status Click on a port to display or configure its settings z z e The shades sensor icon indicates that the sensor is offline To bring a sensor back online select your sensor type from the drop down menu and click save 44 CONTEG RAMOS to complete your networ ULTRA Location System Location Current System Time 02 07 2012 16 54 01 Summary Map Sensors Notification Access Control Settings Applications Help Sensor Settings Sensors Menu 1 2 3 4 5 6 7 8 Auto Sense T Auto Sense AwoSeme E Auto Sense E Auto Sense E Auto Sense Auto Sense _ D Auto Sense Expansion Boards Status e e e e e e e e Power Meter Online e o e e e e e Virtual Sensors This page shows the sensor ports and their respective status and state NIC NIC NIC NIC NIC NIC NIC NIC Click on a
15. Internet Explorer 2 This will reboot the device into update mode Do you want to reboot Click OK The unit will then reboot in safe mode After reboot you will be redirected to the safe mode web interface This can take some time so please be patient The page will display the following message while rebooting ca zm amp gG CONTSG RAMOS to complete your networl ULTRA Location System Location Current System Time 02 07 2012 09 48 30 Summary LET Sensors Notification Access Control Settings Applications Help Firmware Upgrade Rebooting www conteg com All rights reserved CONTEG 2012 d Once the unit has rebooted you will see the following page where is presented Firmware upgrade and system maintenance options with backup for example For upgrade press button Upgrade CONTEG RAMOS ULTRA Warning Do not close or refresh this window If you wish to cancel the process please click the Cancel Upgrade button Cancel Upgrade System Maintenance Clear Event Log Clear Event Log Maintenance Command Clear Sys Log Restore Original Settings Clear All User Data and Restore Original Settings Backup All Settings To Backup File e On the next page follow these instructions CONTEG RAMOS ULTRA Firmware Upgrade 1 Download the firmware file on to vour local hard disk 2 Enter the firmware file name 1 Click here to navigate to the upgrade file you downloaded from 2 Click here
16. RAMOS Ultra User Manual T Activity Status Link Online All rights reserved CONTEG 2012 WWww CcOnteg conm 2012 CONTEG spol s r o All rights reserved No part of this publication may be used reproduced photocopied transmitted or stored in any retrieval system of any nature without the written permission of the copyright owner Although this manual was prepared and checked with the best care CONTEG spol s r o cannot accept any liability for omissions or errors in this publication Due to the continuous development and progress CONTEG spol s r o also reserves the right to change details and technical specifications of the products described in this manual Such changes along with eventual errors or printing errata shall not constitute grounds for compensation www conteg com All rights reserved CONTEG 2012 Content 1 Introduction ERE OE 4 1 1 Whatis RAMOS Itra eee en ene ee PS 4 1 2 ROI MS SAI A oe eaten OO Eom 4 13 Package ONO Emm cuss ateeta nena de 4 Me RI NG oo Emme need de 4 15 doo em ee ee ae Tn ee PC ee ee ee oe ere ae ee ee eee eee er nen reer re eee ce PH 6 2 DNS el eH Ne sae E E E E E E E MI ELM NNNM UM do M E DI ME 7 X EE 2 41 89 Omid peg cae ole g orci Ree mene meee oe Eom T 2 2 Testing the new IP address with the ping Corfilridbldt
17. Sort by Host Name Sorting options are found here Advanced Filter Display Status i Display Sensor Type Display Host Name Select various options to customize your viewing window data Click here to save your changes Reload Sensor Interval 10 Secs _ Apply Syslog Filters Altering your page reload interval can be achieved by using these options shown below Reload Sensor Interval 10 secs To alter your reload time enter a new value here 39 WWW cones COM All rights reserved CONTEG 2012 Once you have selected your preferred filter options your new settings will be displayed in the Sensor Information window found on the summary page EG gs E m RAMGE to complete your netwo Current System Time 03 07 2012 17 01 58 Location System Location Summary Map Display Last refresh 3 7 2012 17 01 54 Data Centre Settings Applications Access Control Sensor Information Sensors Notification Sensor Name Host Name Type RAMOS ULTRA EX 0A000858 Module RAMOS ULTRA EX 0A000858 Main Module Temperature Temperature Port 1 Sensors status will be reloaded in 07 secs Normal RE Normal System Log 0 messages Your changes are display here lt lt System Log will be reloaded in 04 secs Sort by HostName _ x Advanced Filter Display Status Display Sensor Type ke Display Host Name Search
18. Starting init process After the root file system is mounted all green LEDs will be flashing and red LEDs light increasingly from left to right The on board web server can be accessed during this time and shows a splash screen with boot details After the boot process is finished the LEDs show the status of the online sensors d have forgotten my unit s IP address If you have forgotten the IP address of your unit then you can simply press the rest button on the back of the unit This will then announce the IP address through the unit s internal speaker e have forgotten the password for my unit Hold down the reset button for 7 seconds This will turn off the use password feature for the web based interface This will remain turned off until you hold the button down for a further 7 seconds or the unit announces Now turning off password checking Note This will turn off the password checking for accessing the web interface only you still have to enter the password when access the system via telnet 46 www conteg con All rights reserved CONTEG 2012 f Can I use DHCP to assign my unit s IP address Yes you can use DHCP to assign the IP address The unit ships with this disabled Therefore to turn it on you need to log into the web interface and navigate to the Ethernet settings by way of clicking the security tab Ethernet Network and then clicking on the YES button for Use DHCP to complete your netwo
19. a to be imported into your message at the time of sending Please click the Macro Description button for a full list Click Enable Picture to attach a Picture with your message Select to attach either the Current Picture from the Camera or the most recent Picture Stored on the Picture Log Select which Cameras you would like to use as the source of your picture Please select Cancel to leave the edit mode and go back to the menu without saving After this click Next c Now you need to input your SMTP server address for your e mail account Email Action Wizard SMTP Server SMTP Port 25 SMTP Authentication Enabled Disabled SMTP Server Login name SMTP Server Password Timeout 30 Second s SSL TLS Enabled Disabled Once this when is correct click next d Now as with the SNMP trap you can select how many times to attempt to resend the e mail and the time elapsed between each attempt Email Action Wizard Maximum Times to Resend Resend Intervals secs 10 10 secs Resend on Server Timeout Click next when you have filled in your parameters e Now link the e mail we just created to the temperature sensor on port 1 30 WWW cones COM All rights reserved CONTEG 2012 Link Sensor To Action Escalation Module DA Li DA DA DO Main Module enso Temperature Port 1 4 Sensor Filter Module State 7 Dual Humidity V Dual Temperature W Temperatur
20. a Centre Map List Data Centre Sensor Adding Wizard Online Sensors RAMOS ULTRA EX 0A000858 RAMOS ULTRA EX 0A000858 Connection State 9 Dual Humidity Port 1 Dual Temperature Port 1 2 Main Module Temperature Port 1 i7 Help Sensor icon is now placed To prevent the accidental movement of the icon Sensor can be locked Place links on map Press the Unlock button then drag Press the Lock button to continue the Sensor or Sub Map link on to the map More information Left click on Sensor icons to display real time sensor data Camel Lexi Display a map containing the Sensor Press the sensor description on the left column j Finally you click on the Finish button to save your changes 7 2 Monitoring via the map interface Now we are going to look at how to monitor the sensor status and use the map interface To see further information regarding a sensor you can click on its icon First you must click on the Lock Icons button ul cei SF CONTEG RAMGS Location System Location Current System Time 03 07 2012 16 11 49 Summary Lets Sensors Notification Access Control Settings Applications Help Sensor Map Data Centre Map List Online Sensors RAMOS ULTRA EX 0A000858 Main Module Help Place links on map Press the Unlock button then drag the Sensor or Sub Map link on to the map More information Left click on Sensor icons to display real time sensor data Display a map c
21. ansion Port1 Expansion Port4 Power Meter EE mmaa change Name here RAMOS ULTRA EX 0A000858 Graph Module Status Connected Virtual Sensors coy ENS Help Enable or Disable your module here This page shows the list of extended moduless connected Filter Status Enable Disable Click on a module to change its settings 1 2 3 4 5 6 T 8 e e e Click here for H e sensor settings 25 WWW cones COM All rights reserved CONTEG 2012 e Once you have clicked on the Dual sensors tab you will be directed to the familiar looking notification thresholds page From this page you can carry out various operations as indicated in the sensor settings tutorials found on page 16 6 Notifications If you setup a notification you can define the action to take when the sensor gives a reading beyond your previously set thresholds This allows you to determine how you will be notified that a sensors reading has reached the specified parameters high warning critical etc that we looked at in the previous section This tutorial provides you the information needed to setup a notification To get to the starting point of this tutorial e Log in as administrator e Click the Notifications tab 6 1 Adding a notification a First click on the notification wizard 1 g tcONFEG RAMOS ULTRA Current System Time 03 07 2012 10 15 40 Summary Sensors Notification Access Control Settin
22. ations Sensor Settings Sensors Menu Expansion Port1 H a 174 cinta ian y 1 Click on sensor Expansion Portt M ur uA RAMOS ULTRA EX 0A000858 Expansion Port3 Expansion Port1 Expansion Port4 1 4 1 2 Click on Expansion Boards Expansion Port2 Power Meter Add Meter Graph f Virtual Sensors Help Expansion Port2 Click on a port to display or configure its settings Expansion Port3 Move E module Settings If you need to move your sensor setting from one E module f j to another first connect the expantion modules then simply drag the E module icon to the E module you would like to move the settings to and drop it onto that E module Expansion Port3 Please Note You will lose your original settings because this process duplicates sensor ID s which connot be the Expansion Port4 same on the unit Expansion Port4 c Alist of all extended ports will be shown Each port will display any available extension modules these will be highlighted in green Click the module to be taken to the sensor settings page Expansion Port1 a d This will bring you to the following page the extended port sensors page 44 CONTEG RAMS to complete your networ ULTRA Location System Location Current System Time 03 07 2012 10 00 12 Summary LUET Sensors Notification Access Control Settings Applications Help Sensor Settings Sensors Menu Expansion Port1 Sensor Ports Expansion Boards A Expansion Port2 Expansion Port3 Exp
23. be entered by separating addresses by a comma or semicolon Please select Cancel to leave the edit mode and go back to the menu without saving RAMOS ULTRA Sensors Notification Access Control Email Action Wizard Settings Write a name of email action Mail From Mail To Write a recipient acc Mail BCC Current System Time 03 07 2012 13 18 44 Applications Help b After clicking Next you will get a page where you can input the e mail name and message Press the Customize button and the fields will re write in a format that will allow for an automated e mail that will display the sensor information 14 CONTEG to complete your networl Location System Location Summary Notification Menu Begin Notification Wizard Action Add Action Link Sensor To Action Options View Notification Log Notification Analyzer Help This is a preview of the message that will be sent to your recipient s The sent message will include the details relevant to your sensor Click Customize to change the format of this message The items in your message with a dollar sign and parentheses e g TIME represent the data to be imported into your message at the time of sending Please click the Macro Description button for a full list Click Enable Picture to attach a Picture with your message Select to attach either the Current Picture from the Camera or the most recent Picture Stored o
24. creen shots 12 www conteg com All rights reserved CONTEG 2012 3 1 Group Setup A CONKEG RAMOS ULTRA Z 1 Click on Settings Current System Time 02 07 2012 12 34 21 Access Control Settings Applications Location System Location Sensors Notification User amp Group Managemen Setup 4 lo SEC 4 Click on Groups System Date and Time User Name Group Name Description Login session timeout minutes Connectivity Admin Administrator Built in account for administrator 60 Server Integration User User Built in account for user 60 V Cannot remove LA 2 Click on System Administrator mD coena Cross System Maintenance A tt Services and Security 3 Click on User amp Group Management System Log Heartbeat Messages Cloud Monitoring Help This page allows enabling creation and changing of the User and Admin password This will take you to the Groups page shown below CONTEG RAMOS c to complete your networl Lt ULTRA Location System Location Current System Time 02 07 2012 13 17 21 Summary Map Sensors Notification Access Control Settings Applications Help User amp Group Management Setup System Date and Time Connectivity Server Integration System Administrator ca Sere CProperties Password Checking User amp Group Management System Maintenance Services and Security System Log Heartbeat Messages Cloud Monitoring Group Name Description
25. cription Login session timeout minutes System Guest Goto Group Setup DA Member of Group Current System Time 02 07 2012 14 51 16 Applications Help 4 User Cannot Change Password Press Finish when entry all data Now enter your User details as shown above In our example we have entered Thomas as our Guest into our System Guest group We have also added the option so that this user cannot change his Log in password After adding your users for each group click the Finish button to save each user G CONTEG to complete your networ Location System Location Summary Setup General System Date and Time Connectivity Server Integration System Administrator Password Checking User amp Group Management System Maintenance Services and Security System Log Heartbeat Messages Cloud Monitoring Help This page allows enabling creation and changing of the User and Admin password ULTRA Access Control User amp Group Management Sensors Notification Settings Current System Time 02 07 2012 15 02 34 Applications Help User Name Group Name Description Login session timeout minutes Admin Administrator Built in account for administrator 60 er T Built in account for use 50 Thomas System Guest Guest 60 Cannot remove Now as you can see the new user has been entered into our list of Users 4 CONTEG to complete your networl Location System Location Summary Setup
26. cus on the CONTEG temperature sensor however this basic set up process is applicable to all of our sensors If you require information on specific functions of a particular sensor then please download the manual for that sensor from our website or locate it on your product CD a Plug the sensor into one of the RJ45 intelligent sensor ports on the rear panel of the unit In this example we will use port 1 Connect Sensor to one of the ports on the rear of the unit 18 www conteg com All rights reserved CONTEG 2012 b Now point your browser to the IP address of the unit default 192 168 0 100 Next you need to log in as the administrator using your administrator password default is public You will then be taken to the summary page This is shown below S CONres RAMOS to complete your networ ULTRA Location System Location Current System Time 02 07 2012 15 50 45 Summary LET Sensors Notification Access Control Settings Applications Help Summary Setting Sensor Information Layout Setting Host Name Type Sensor Name Reading Status Sensor Filters Main Module Temperature Temperature Port 1 25 5 C Normal Sensors status will be reloaded in 02 secs Sort by Host Name _ x System Log 0 messages Advanced Filter Display Status ioi Display Sensor Type A t Display Host Name Search Sensor information listed here Apply Filter Clear Filter y Expand All Modules_ Collapse All Modules v System Log
27. d ausznreandksexus bx wax REM ERR Max s RES FE award PRU aa UR VC wa ME UURSEE Rr Ri dRM eUa CIE PRX CURIE MU EH URS CE NE 8 23 SPRimnware UDEIBEIB nomiue ameet 9 3 M lti sers and ErouUps SE UD c sore ics veered eens tw ear E re rE eA se ces ei em see tet ew see 12 CN MEME 518 0 SEUD NE mo mee ete ee meee eT mes eee mC aon en eee eter ee ee toe eee eee ee ee meee ee 13 32 S acci RNC ane E ne eee ne ene cree E eee ee mn NET eee Ce mC rent E 14 4 Sora diez and Ee 2160 1 Aenea eee ncn mene neo EE naan Cane eer enon TN 16 EE 81401037 0 41 ETT TT E E E E E e E e 18 B28 ANGIE CARO MIU Ml C PREIS Tm R 20 43 Advancedsensor ECT TTE ETT Tom 22 4 4 Continuous time sensor settings seeeseeieseseeeeee eene nenne nnne nnne nes su se suu suse spesa se sse sese eese se spese se sse sese see sese sense se spese sesta se sense se sese se sse EGGS 23 5 EXPANSION OES resssoucesiesas E E E ase Utu AM Re MAE dre iSA D SERM satanic E E ANE R DADO EE SER EFIE E E E FENDER LEUL IE 24 6 MOTI CANONS MNT T TT aE 26 61 Adding a notficaUONs seese E E E E E E E E EA E Ea E EEE E 26 I AD E E E etneeehamahawaceneasaeeeseanans 27 A aes ce go cece EE E EEEE EEEE EAE E AE E E A EA 29 6 4 SIS notification NR P 31
28. dd Action Please select an Action Type SNMP Trap SNMP Trap El Link Sensor To Action z SMS View Notification Log FTP Notification Analyzer 1 Se l e ct a ct i O n crtom Script Siren Help Wake Up Shutdown Windows Alert Please select an Action Type from the pull down box Skype Call SMS Later your action will be linked to a sensor and Dry contact status Enable Disable Sensor To Action Modbus Alarm Sound Speech Sound Log Telephone Call 2 Select Next 26 www conteg com All rights reserved CONTEG 2012 We will now go through setting up a few different ways of notification step by step To learn what the other types of notifications do refer to the separate notification manuals that can be found on your product CD 6 2 SNMP trap First we will set up a notification via SNMP trap so that when your sensor reaches a certain threshold it will send a notification to your SNMP server This tutorial provides you the information needed to setup an SNMP trap To get to the starting point of this tutorial Log in as administrator Click the Notifications tab Choose Notifications wizard Choose SNMP trap a After selecting to add an SNMP trap you will need to fill in the following information Notification Access Control Settings Applications SNMP Trap Action Wizard Enter name for your SNMP notification Trap Version v1 v2c v3 SNMP Trap send port default is 162 162 Destination Addres
29. e 1 Select your 2 Select your sensor cesi H 3 Click Next Link Sensor To Action Escalation Status High Critical E Action Em l Action Filter V SNMP Trap V Email Sensor Error 5 Select the name of the 4 Select status for more options email you just created hold Ctrl and select status lick Finish Click on Finish You will now be taken back to the main Notification tab f Atthe main notification page you should now see listed our two notifications the SNMP trap and the e mail Host Nam Sensor Name Action on Status Action Name m r Main Module Temperature Port 1 High Critical fe SNMP Trap 1 A Main Module Temperature Port 1 High Critical 0 3 Email 1 Import notification from file Vybrat soubor Soubor nevybr n Import c Export As you can see from this page we now have an SNMP trap set up not give us notification of a High Critical and an E mail notification that will activate on a High Critical 6 4 SMS notification Now we will set up a notification so that you will be sent an SMS message This message can be sent via a GSM GPRS mobile phone connected via a Bluetooth connection or the USB port 31 WWW cones COM All rights reserved CONTEG 2012 This tutorial provides you the information needed to setup a SMS notification To get to the starting point of this tutorial e login as
30. educe the amount of false warnings when temperatures are frequently fluctuating is to set the A a ae Rearm feature here This is similar to the Continuous 5 Time feature as it will filter out or not allow additional alerts Low Critical 10 20 30 40 High Critical P e Low Warning High Warning to be sent if the temperature fluctuates within the degree h h d d virens Threshold Adjustment Low Critical Low Warning High Warning High Critical Continuous Time for Sensor 10 20 30 40 One way to eliminate false warnings in an unstable temperature ennvironment is to add time in the continuous Current Reading 25 5 C time to report feature here Status Normal Minimum Time Satu Online Offline Status Option Prevents the status from fluctuating within the time set Eg Sensor can only show high critical state once within 3 seconds if value is set to 3 seconds _ Save _ Reset Note another way of accessing this page is to click on the sensors tab at the top of the page 19 www conteg com All rights reserved CONTEG 2012 4 2 Notification thresholds From this page you can carry out various operations as indicated above Also view the current status normal low critical high critical etc In the screen shot above you can see the sensor is indicating a temperature of 25 5 degrees C and a status of Normal If you click on the blue marker arrow indicated above by the Set the required threshold label you can drag
31. em you are connecting For the purpose of this tutorial we will assume you are connecting a GSM GPRS enabled modem to the USB port Therefore we will select USB Modem from the list e SMS Action Wizard Select type of connection Mobile Phone Port Speed Delay Time Between Sending PDU Packet 0 Delay Time Between Sending Connection 0 Select for Initialization String Other Custom Setup Initialization String You will now be able to select the number of times you wish the SMS to be resent and the interval between sending them f SMS Action Wizard Maximum Times to Resend Resend Intervals secs 10 Resend on Server Timeout f g Again we now select the sensor to which to bind this notification too Select number of times to resend and 33 www conteg com All rights reserved CONTEG 2012 Link Sensor To Action Escalation Module DA EI DA DA DOS Main Module enso Sensor Filter Temperature Port 1 WV Module State V Dual Humidity V Dual Temperature V Temperature 2 Select your sensor 1 Select your cessi Cus J 7 3 Click Next Link Sensor To Action Escalation Status Action Action Filter High Critics V SNMP Trap J High Warning ij V Email Low Warning SMS 5 Select the name of the email you just created 4 Select status for more options hold Ctrl and select status 6 Click Finish Ce
32. gs Applications Link Sensor To Action Location System Location Notification Menu Begin Notification Wizard Link Sensor To Action Escalation Action Host Name Sensor Name Action on Status Link Sensor To Action Action Name Options View Notification Log cene Lo Edi Create Escalation Remove Notification Analyzer 2 Help 2 Import notification from file Vybrat soubor Soubor nevybr n Import Export This is an overview of all configured Sensor Action Links From here you may create edit and remove Sensor Action Links Select your desired Sensor Action Link s before making a choice Each line should be descriptive E g If Temperature in Store room Is High Critical Then E mail Store Room Manager To disable or enable the notifications without having to delete them in the Link Sensor To Action listing just uncheck the checkbox to disable them or check the checkbox to enable them b You will now have the notification wizard page displayed shown on the next page S CONTE RAMOS o complete your networ ULTRA Location System Location Current System Time 03 07 2012 10 22 45 Summary LLETY Sensors Notification Access Control Settings Applications Help Create Action Notification Menu The Notification Wizard will guide you step by step through the process of selcting a sensor creating an action and defining the criteria under which the Notification will Begin Notification Wizard be sent Action A
33. he sensors into the map press the Unlock button Display a map containing the Sensor Press the sensor description on the left column Click the Unlock button to continue h You can now drag sensor icons and position them on the map mat to complete your networ ULTRA Location System Location Current System Time 03 07 2012 16 02 47 Summary Sensors Notification Access Control Settings Applications Sensor Map Data Centre Sensor Adding Wizard r zal Data Centre s Online Sensors RAMOS ULTRA EX 0A000858 RAMOS ULTRA EX 0A000858 Connection State Dual Humidity Port 1 Dual Temperature Port 1 Main Module Temperature Port 1 Options Ll Help Sensor icon is now placed To prevent the accidental movement of the icon Sensor can be locked Place links on map Press the Unlock button then drag Press the Lock button to continue the Sensor or Sub Map link on to the map More information Left click on Sensor icons to display real Cancel ext time sensor data Display a map containing the Sensor Press the sensor description on the left column 37 www conteg com All rights reserved CONTEG 2012 i After you have positioned the sensors in the correct location of your map click on Lock This Map to complete your networl ULTRA Location System Location Summary Current System Time 03 07 2012 16 02 47 Sensors Notification Access Control Settings Applications Sensor Map Dat
34. hell Telnet Web Interface HTTP port to use 50 Secure Web Interface HTTP S porttouse 443 Available Port You can also close or change the ports used to access the units web interface disable HTTP and enable HTTPS only The s at the conclusion in HTTPS stands for secure This SSL TLS connection type is used primarily for high value sites or pages to elevate the potential of being unreadable by anyone but the end points One benefit is the traffic between client and the RAMOS Ultra is not cached along the various units as it moves across the Net and so can t be accessed by someone after the connection is terminated 16 WWW cones COM All rights reserved CONTEG 2012 The SNMPv3 SSL security feature Active Services Services and Security Active Services Nagios Secure Shell Telnet Web Interface HTTP portto use 60 Secure Web Interface HTTPS porto wse 1443 Albis Port Simple Network Management Protocol Version 1 SNMPv1 Simple Network Management Protocol Version 3 SNMPv3 C Serial to Network Proxy ser2net AKCess Pro Server Integration Ethernet Watchdog Use the SNMPv3 SSL Secure Sockets Layer which is the standard security technology for establishing the encrypted link between the RAMOS Ultra in our case and the web browser This link ensures that all data passed between the RAMOS Ultra and the browser remains private and integral SNMPv3 provides important
35. ial Out Modem Member of Group Administrator Goto Group Setup OpenVPN Client E certum 2 Press Finish System Administrator Password Checkinq System Maintenance Services and Security System Log Heartbeat Messages Cloud Monitoring Help This page allows enabling creation and changing of the User and Admin password i What function do the different types of notifications provide The notifications are used to notify you when a sensor reading has hit a certain pre set critical threshold There are many ways you can be notified They are as follows SNMP Trap This form of notification sends out a signal to your SNMP server E Mail This sends a notification via e mail SMS This sends an SMS message to your mobile phone Alarm sound This notification will sound an alarm 48 WWW cones COM All rights reserved CONTEG 2012 Speech Creates a text to speech notification Telephone call Will call you and play a pre recorded message or a text to speech message Custom script Allows you to load a custom script that runs on a sensor reading a pre set parameter Fax Will send a Fax to you with a notification message Sound log creates a log of sound captured with the internal external microphone Siren and strobe will activate a siren and strobe light Wake up Shutdown This will send a signal to wake or shut down a server If you require any assistance in setting up of these please contact u
36. ing to use a 3D map of a data centre we are monitoring UFEG g S a ea RAMOS Location System Location Current System Time 03 07 2012 15 41 57 Summary LETS Sensors Notification Access Control Settings Applications Help Sensor Map DC_001 jpg Map List Wc ap Wiza DC_001 ipa Online Sensors Map uploaded successfully o Please enter the Map Name ptions Help e e the Sensor or Sub Map link on to the map 1 Choice a name for picture mco More information Left click on Sensor icons to display real Place links on map Press the Unlock button then drag time sensor data Display a map containing the Sensor Press the sensor description on the left column 2 Cl i C k O n S N ext d Choose to have the map as a top level map Map Wizard This Map can be assigned as a sub Map or as a top level map Please assign parent map for this map Select Parent Map Set as Top Level 1 Select as top Level picture Bact De 2 Click on Next e You will now have the option to finish or to continue adding your sensors to the map For this tutorial click next Map Wizard Map added successfully Click Finish to close this wizard or click Next to continue to the Sensor Adding Wizard tmin conn Click on Next f You will now be taken to the map page where it will display your map To continue adding the sensors click next 36 www conteg com All rights reserved CONTEG 2012 mae to
37. is tutorial Log in as administrator Click the map tab 7 1 Adding a map a First we need to add a picture file to be used as the map This can be a blueprint of your office a 3D picture of your office site being monitored or a photo of the wiring closet you are monitoring CON zu RAMIS g N EL 1 Click on Map tab ULTRA Location System Location Current System Time 03 07 2012 15 24 26 Summary Map Sensors Notification Access Control Settings Applications Sensor Map Untitled 01 Map List No Map Uploaded Online Sensors RAMOS ULTRA EX 0A000858 Main Module Eoo 2 Click on tet Add New Map oy Maj Please upload map file Place links on map Press the Unlock button then drag the Sensor or Sub Map link on to the map More information Left click on Sensor icons to display real time sensor data Display a map containing the Sensor Press the sensor description on the left column 100 00 Zomin Zoom Out _ Fullscreen Mode _ Refresh Map Sensors Interval sec 5 Sensors status will be reloaded in 03 secs 35 WWW COnted conr All rights reserved CONTEG 2012 b Now you can browse to the file on your HDD you wish to use Sensor Map Untitled 01 Map Wizard Please select a Map picture to upload JPEG or GIF format Maximum 2 MB 1 Click on Browse to select a picture Upload new Map em nn J 2 Click on Next c In this tutorial we are go
38. it using the default password 47 www conteg com All rights reserved CONTEG 2012 2 Point towards the settings tab Po aS al e X CONESG RAMOS YA Click on Settings User amp Group Manage Current System Time 04 07 2012 13 58 36 Sensors Notification Applications Setup System Date and Time User Name Group Name Description Login session timeout minutes Connectivity Admin Administrator Ethernet Network Lll Un Thomas System Guest Guest 60 Wifi Network Modbus Cannot remove e 3 Select the User RE Administrator Serial to Network Proxy 4 Click on Properties Services and Security System Loq Heartbeat Messages Cloud Monitoring m 2 Click on System Administrator and Baked La e e E E T then on User amp Group management 3 Click on properties which will bring you to the following page XX CONTEG RAMOS o complete your netwo ULTRA Location System Location Current System Time 04 07 2012 14 07 03 Summary Map Sensors Notification Access Control Settings Applications Help User amp Group Management Setup System Date and Time System Date and Time User Setup Connectivity Enter the user name password descritption and then select the member of the group Ethernet Network User Details User Name Admin j User Cannot Change Password I 1 Input a new passwords Login session timeout minutes 60 D
39. k on Ethernet Gateway IP Address 192 168 168 250 Wifi Network k Domain Name Server 192 168 168 5 zs networ eere Ethernet MAC ID 00 0B DC 00 02 F5 SNMP Ethernet Media Mode 100baseTx FD negotiated link ok Bluetooth Dial In Modem Dial Out Modem OpenVPN Client Serial to Network Proxy Server Integration 4 Click on Save System Administrator Help This page allows the system IP settings to be configured centrally by DHCP or manually Note The unit ships with DHCP disabled If you wish to use a DHCP server to obtain the IP address then see the Using DHCP section of the FAQ 2 2 Testing the new IP address with the ping command Once you have assigned the new IP address use the ping command to test the unit This can also be used as a diagnostic tool in order to check whether your unit is connected to the network WWW contes COM All rights reserved CONTEG 2012 l EN Spravce C Windows Microsoft Windows Verze 6 1 76611 Copyright lt c gt 2009 Microsoft Corporation USechna pr va vyhrazena C Users tgrafPping 192 168 168 168 P kaz PING na 192 168 168 168 32 bajt dat ed od 192 168 168 168 hajty 32 Eas ims TTL 64 d od 192 168 168 168 bajty 32 Eas lt ims TTL 64 d od 192 168 168 168 hbajty 32 Eas lt ims TTL 64 d od 192 168 168 168 hajty 32 Eas lt ims TTL 64 Statistika ping pro 192 168 168 168 Pakety Odeslan 4 P ijat 4 Ztracen Cztrata M
40. lable Display Sensor Type Display Sensor Status Reload Syslog Interval 10 secs Appy By checking and un checking various boxes within the Syslog filter window you can customize your displayed results contained within the syslog filter Sort by Dat Sorting options are found in the drop down menu Humber of display items per page Advanced Filter amp Display Log Level Various check boxes can be picked and UE unpicked to customize vour filter window W Notices isplay Lag Type Wi Sensor Log Notification Lag isplay Notification Click here to save your selection App To change your reload interval enter a new value here and click Apply Altering your reload interval can be achieved by using the options shown above Once you have selected your preferred filter options your new settings will be displayed in the System log Information window found on the summary page 41 www conteg com All rights reserved CONTEG 2012 gt d ac g ON Eu RAMOS to complete your netwoi ULTRA Location System Location Current System Time 04 07 2012 09 39 02 C Summary Sensors Notification Access Control Settings Applications Help Map Display Sensor Information Last refresh 4 7 2012 09 39 01 Host Name Type Sensor Name Reading Status ecu RAMOS ULTRA EX 0A000858 Dual Humidity Dual Humidity Port 1 55 Normal Dual Temperature Dual Temperature Port 1 24 2 C Normal Main Module Temperature Temperature
41. ll filter out or not allow additio a a rts to be sent ifthe temperature ftem within the ope Display Style Basic Style Gauge Style this n set to Check rate of change Enable Disable Continuous Time for Sensor One way to eliminate false warnings in an unstable Enable Graph On Off temperature ennvironment is to add time in the continuous time to report feature here Popup Windows on Sensor Name Sensors URL Minimum Time Status sen Open linkin Current Windows New Windows Previ status from fluctuating in se time set Eg ensor only show high critical si within 3 eid pend is setto3s ihn Filter Status 9 Enable Disable Enable Calendar Advanced mode functions Units changes units from C to F or vice versa Rearm The Rearm parameter is useful for sensors whose values can vary such as the temperature and humidity sensors It is used to prevent the sensor from flickering between two states For example if the Warning High threshold for the temperature sensor is set to 80 degrees and the sensor were to vary between 79 and 80 you could be faced with a very large number of emails traps and events logged The Rearm parameter prevents this by forcing the temperature to drop by the Rearm value before changing the state back to normal In this example if Rearm is set to 2 then the sensor would have to drop from 80 down to 77 before the status would change from Warning High back to normal Reading offset A calibration to
42. lso can be used to indicate system status when undertaking various operations 1 The LEDs will indicate the progress of an upgrade The red LEDs will move from left to right to indicate activity and the green LEDs will indicate overall progress of the upgrade When all the red lights are off and all green are on the upgrade recovery process is complete 2 These lights will indicate if the unit is operating in safe mode This is when the unit loads the Operating System OS with a minimal set of drivers If your device enters safe mode after rebooting then please contact us on ramos conteg com 3 The unit may enter recovery mode if a firmware upgrade has been incomplete This will be indicated by the unit displaying a continuously lit row of red LEDs If this happens please contact us on ramos conteg com 4 Mic The mic is a small hole for access to the internal microphone This can be used as a sound sensor or an external mic can be used 5 Expansion Ports There are four expansion ports numbered from E1 E4 These are expansion Ports for connecting either the 8port expansion or 16 dry contact expansion modules 6 Removable SD slot This slot so where you can place your SD card which can store data such as pictures taken from the CCTV camera sounds recorded from the internal microphone and also the current firmware of the unit Supported card size is up to 32GB SD card is not included www conteg com All rights reserved
43. m the RAMOS Ultra and all the network traffic You can then import the captured file into Ethereal or TCP dump for details of these network packets The network trace will help in debugging any network problems for example if e mail cannot be sent 50 www conteg com All rights reserved CONTEG 2012
44. ment aa As before select the Temperature sensor on port 1 This time we will use this notification for a High Warming Then select the notification name we assigned in this case we chose SMS 1 Click Finish to finalize this h You will now be back at the main notification page Now the page should display three types of notifications the SNMP trap E mail and SMS Link Sensor To Action Escalation Host Name Sensor Name Action on Status Action Name 4 Main Module Temperature Port 1 j High Critical 00 fy SNMP Trap 1 j ji A V Main Module Temperature Port 1 High Critical 00 e Email 1 H j A A B A fz j j Import notification from file Vybrat soubor Soubor nevybr n Import Export 34 WWW cones COM All rights reserved CONTEG 2012 For the purposes of this tutorial we will not cover the setup of every type of notification However with this information you should be able to follow the procedure for the other types of notifications easily as they all follow a similar format If you still encounter difficulties with this then please contact us on ramos conteg com 7 Mapping The mapping feature allows for an instant visual feedback as to a sensors position and status It is a useful monitoring tool for a set up with several sensors in different positions This tutorial provides you the information needed to setup the mapping feature To get to the starting point of th
45. mmary ET Sensors Notification Access Control Settings Applications Help User amp Group Management Setup General i n n n n System Date and Time E Group Name Description Login session timeout minutes Connectivity Admin Administrator Built in account for administrator 60 Server Integration User User Built in account for user 60 System Administrator Cannot remove Password Checking 1 Select Users DED me System Maintenance Services and Security System Log Heartbeat Messages Cloud Monitoring 2 Se ect Ad d Help This page allows enabling creation and changing of the User and Admin password Click on the Users tab then click the Add button to add the new Users to your groups as shown above 14 WWW cones COM All rights reserved CONTEG 6 2012 S CONTEG to complete your networl Location System Location Setup General System Date and Time Connectivity Server Integration System Administrator Password Checking User amp Group Management System Maintenance Services and Security System Log Heartbeat Messages Cloud Monitoring Help This page allows enabling creation and changing of the User and Admin password ULTRA Access Control User amp Group Management Notification Sensors Settings User Setup Enter the user name password descritption and then select the member of the group User Details User Name Password Confirm Password Des
46. n the Picture Log Select which Cameras you would like to use as the source of your picture Please select Cancel to leave the edit mode and go back to the menu without saving RAMS ULTRA Sensors Notification Access Control Email Action Wizard Settings Subject Testing Sensor Port 1 on BOARD_DESC is now 8 Body From System Name 192 168 161 237 Time 13 14 43 Testing Sensor Port 1 on BBOARD DESC is now 80 Unit status is now Normal Click on customized 29 All rights reserved CONTEG 2012 Current System Time 03 07 2012 13 26 34 Applications Help www conteg com ig0 ZX CONTRS Location System Location Current System Time 03 07 2012 13 28 42 Summary LUET Sensors Notification Access Control Settings Applications Help Email Action Wizard Notification Menu Begin Notification Wizard Subject SIDE SCRIPTION on BOARD_DESC is now VAL Action d Add Action DESCRIPTION on S BOARD DESC is now TIUS E VALUE S UNIT status is now STATUS Options View Notification Log Notification Analyzer Help This is a preview of the message that will be sent to your recipient s The sent message will include the Cl ic k Oo n Atta C h G ra p h if details relevant to your sensor Click Customize to change the format of this yo u WO u d i ke a gra p h a d d ed message The items in your message with a dollar sign and parentheses e g TIME represent the dat
47. ng As above but delays notification for Low Warning state Continuous Time to Report for Low Critical As above but delays notification for Low Critical state Continuous Time to Report for Sensor Error As above but delays notification being sent for sensor going into an error state Example An airflow sensor or humidity sensor may have temporary drops in readings which are normal operating characteristics a logical time limit is set to show abnormal conditions 5 Expansion Ports The RAMOS Ultra is equipped with four expansion ports This enables you to connect up to four daisy chains of expansion modules The available expansion modules are an eight port intelligent sensor board and an Opto isolated sixteen dry contact expansion module In this section we will go through the basic setup of the sensor If you require information on specific functions of a particular sensor or expansion board then please refer to the relevant manual for that product a Plugthe expansion board into one of the four ports located on the front panel of the unit These are numbered E1 E4 24 www conteg com All rights reserved CONTEG 2012 b From the summary page navigate to the Sensors tab Then click Expansion Boards as outlined in the image below gZ coNFEG REIMGS to complete your networl ULTRA Location System Location Current System Time 03 07 2012 09 35 03 Summary Sensors Notification Access Control Settings Applic
48. nterval e ect Settin S ta b Then Apply g Syslog Filters Requesting data All rights reserved CONTEG 2012 www conteg con b S GCONTES RAMOS to complete your networ ULTRA Location System Location Current System Time 21 01 2000 19 45 17 Summary LETS Sensors Notification Access Control Settings Applications Help System Maintenance Setup Clear Syslog Car General Clear RRD datalog Clear ionii 1 ci IC k on m Syste m Restore Original Settings Restore Keep present network setting Server Integration e o u mm z Ad ministrator Clear All User Data and Restore Original Settings Clar a C Keep present network setting CHNEUSUQOUEEU Backup All Settings To Backup File _ Backup Soubor nevybr n User amp Group Management Restore All Settings From Backup File p System Maintenance Restore Keep present network setting Services and Security 2 ci ick on Syste m product conteg com Send Configuration To Support a j ES System Log M a i nt enanc e Send Click here to setup SMTP Server Heartbeat Messages System Firmware Upgrade Cloud Monitoring System Firmware Help This page allows you perform all system maintenace of cleaning logs backing up and restoring settings You can also send a configuration file directly from this page and check and apply 3 Cl i ck on U pgrad e x for latest firmware updates c You will then be presented with this pop up Microsoft
49. oggle Working Hours To Clear Set Click Hour Day AM PM All Report Do Not Report To Clear Set the Whole Hour Click a Cell To Select a Minute Right Click a Cell Mouse Over will display minute offset Monday 4 4 Continuous time sensor settings The following advanced functions are for setting the time frame in which the system should delay a notification being triggered when a sensor gives a reading that exceeds the thresholds high warning normal etc 23 WWW cones COM All rights reserved CONTEG 2012 Normal Settings Advanced Settings Continuous Time Settings Minimum Time Settings Continuous Time for Sensor to be in new Status before accepting new Status High Critical 0 High Warning 0 Normal 0 Low Warning 0 Low Critical 0 Sensor Error 0 Save _ Reset _ __Set Thermostat Online _ Continuous Time to Report High Critical This helps to eliminate unnecessary messages during minor fluctuations You can set the amount of time to delay a notification of a status change from high warning to high critical Enter the time in seconds and press the Save button The amount of time that can be entered is between O and 65535 seconds which equals approximately 18 hours Continuous Time to Report High Warning As above but delays notification for High Warning Continuous Time to Report for Normal As above but delays notification for return to Normal state Continuous Time to Report for Low Warni
50. ol If you wish to calibrate the temperature sensor for example you could enter an offset value of 5 This would mean if the sensor reads 20 degrees then it would record as 25 degrees This figure can also be a minus figure e g 5 would show 15 degrees instead of 20 22 www conteg com All rights reserved CONTEG 2012 Enable Calendar If you select this option then the following will be displayed Enable Calendar Off P U AM PM 1212 3 45 6 7 8 9 1011121 2 3 4 5 6 7 8 9 1011 Sunday w Re aea RRR wednesday MBNEEEBENENEEEEESENEEEEEEEE towsdey SRR RRR c NENENEEEENEENEEEEEEEEEEEEE Toggle Working Hours To Clear Set Click Hour Day AM PM All Report ga To Clear Set the Whole Hour Click a Cell Report To Select a Minute Right Click a Cell Mouse Over will display minute offset In our example we wish to monitor an office building between the hours of 7 PM 9 AM Monday Friday only You can see in this picture we have selected the Do Not Report option for the hours in which we do not wish to receive any notifications or have any events logged You change the status of that time frame Report Do Not Report by simply clicking on the square This will change it from blue to grey a second click will return it to blue Enable calendar 0n Off oe cen ree Ee een vc ed 5 mENHNHN we MENU Thursday mn e ENENHENHENENENIN 8 saway T 1 FL T T T T T TL TTL TL rt T
51. ontaining the Sensor Press the sensor description on the left column Type Temperature Sensor Name Temperature Port 1 Reading 23 5 C Status Normal f i oou Sensor Config E ins Icon Settings 100 00 Refresh Map Sensors Interval sec 15 Apply Sensors status will be reloaded in 05 secs If you connect other sensors these too can be dragged and positioned on the map 38 WWW cones COM All rights reserved CONTEG 2012 8 Filters 8 1 Sensor filters The module now comes equipped with the option to filter your sensor information which is displayed within the summary page To enter the filter menu select Sensor Filters from the dropdown tab on the left of the page gene qe G coONFEU RAMOS to complete your networl ULTRA Location System Location Current System Time 03 07 2012 16 28 29 Map Display Sensor Information Last refresh 3 7 2012 16 28 26 Host Name Type Sensor Name Reading Status ata Ci Sensors status will be reloaded in 08 secs System Log 0 messages System Log will be reloaded in 02 secs Summary Setting Sor y HostName T TN disi Click on Sensor Filters to open an option Display Sensor Type Display Host Name Search Reload Sensor Interval 10 secs Apply Syslog Filters Once you have clicked the tab you will be able to select your filter results by altering various fields of information contained within sensor filter window Sensor Filters
52. play Sensor Type Click on Display sensor type and Say Sensor Sous check the box marked Temperature 4 Normal W High Warning Reload Syslog Interval 10 secs Apply E Di amp amp amp TI n click on Apply Filter Next click on apply filter The temperature sensor should then be displayed in the list of connected sensors b cannot access my units web interface If you are having issues with network connectivity first ensure that the link100 LED is lit on the front display of the unit If this is not lit then you have no network connection present If this is the case then ensure the following 1 If connected directly to a PC ensure a good quality crossover cable is being used 2 Ensure a standard CAT5 Ethernet cable is being used to connect to your network 44 www conteg com All rights reserved CONTEG 2012 c What do my LED lights mean The following diagrams show what the various LED displays mean LED patterns in Normal mode then LED patterns in Safe mode then 45 All rights reserved CONTEG 2012 LED patterns in Recovery mode then LEDs run clockwise after the power is connected From left to right each LED indicates 1st LED U Boot init 2nd LED Kernel loaded with good CRC 3rd LED Board init 4th LED Serial port 5th LED Ethernet 6th LED NOR Flash 7th LED NAND Flash 8th LED Root file system mounted
53. port to display or configure its settings Please reconnect the sensor or select your sensor for this port below 1 Click on picture ae ame Ga 3 Click Save AC Voltage f k Airflow Digital Voltmeter of sensor socket Dry contact O Dual Sensors Fuel Level Sensor Liquid Rope Motion Power Probe Switch Relay Security Siren 2 Select Temperature CCEE 21 www conteg com All rights reserved CONTEG 2012 4 3 Advanced sensor settings Near the bottom of the sensors page you will see the advanced mode button Normal Settings Advanced Settings Continuous Time Settings J Sensor Name Temperature Port 1 By clicking this you will get the following options Minimum Time Settings X CONTEG REIMS ULTRA Location System Location Current System Time 02 07 2012 17 17 04 Summary Map Sensors Applications Sensor Settings Sensors Menu MM I Expansion Boards Expansion Boards Status e Power Meter Online Virtual Sensors Hel This iM shows the or ports and their respective status te Minimum Time Settings Click on a port to display or configure its settings Helpful Suggestion Units Fahrenheit Celsius Ream 2 Rearm 5 S EU m Reading Offset 0 ne way to reduce the amount e warnings wl temperatures are frequently fluctuating is to set Data Collection Type Average Rearm mig here This is PN to the Contin Time feature as it wi
54. r RAMOS ULTRA ensors Default Interface 3 Click on Yes IP Address Current System Time 04 07 2012 13 36 06 Ethernet Netwo v Use this Interface as the Default Gateway UseDHCP Yes No DHCP Yes No 192 168 161 237 activate DHCP Subnet Mask 255 255 255 0 192 168 161 250 192 168 161 5 Gateway IP Address Domain Name Server Ethernet MAC ID 00 0B DC 00 02 F5 Ethernet Media Mode 100baseTx FD negotiated link ok 1 Click on Settings 2 Click on Connectivity and then on Ethernet network This page allows the system IP settings to be configured centrally by DHCP or manually Note If the unit has a static IP address assigned it will no longer send out DHCP requests If you later wish to turn DHCP back on you can do that using the Web based interface g How do I set up my routing table To set up the routing table open a DOS window start run type command press enter and at the command prompt enter gt route add 192 168 0 100 10 1 1 20 Where 10 1 1 20 is the IP address of the Ethernet interface on the PC that the unit is plugged in with the crossover cable Now ping 192 168 0 100 to see if the connection was successful h How can I change my administrator password If you wish to make your unit more secure and change the administrator password from the default public to your own choice follow these steps 1 Loginto your un
55. r the basic set up and common configurations of the unit and give an introduction to its most useful features At the end of the manual there is a FAQ section that provides some further in depth information regarding specific set ups and answers some commonly asked questions If you need any further information or help with using your unit then please contact us on ramos conteg com 1 3 Package Contents Your RAMOS Ultra package contains the following items e 1x Product CD e 1x 1 5m Crossover or straight cable e 1x 7 5 V 3 A power supply e 2x Brackets for rack mounting e 1x First run manual 1 4 Front panel Activity Status Power Link i d Online The front panel has several LEDs which display the units status and notify you as to its activity WWW cones COM All rights reserved CONTEG 2012 1 Power LED When the unit is powered up the power LED will be lit continuously If the power LED is flashing then it indicates a problem with the CPU If you notice this then please contact us on ramos conteg com 2 Ethernet LED The Activity and Link LEDs indicate network connectivity and activity The Link LED will light up when there is a network connection present The activity LED will flash when there is network traffic being sent or received by the unit 3 Status Online LEDs These are numbered 1 8 They are used to indicate the connectivity status of the sensors connected to each port These LEDs a
56. s 192 168 0 XXX Community public Enter the IP address of your SNMP trap Use Sensor Name Enter community name of trap b Once this information is correct you can press the Add Trap Destination button After clicking this you have the option of inputting another trap or clicking on Next Now you can enter the following parameters Access Control Settings Applications SNMP Trap Action Wizard Maximum Times to Resend Resend Intervals secs 10 10 secs These parameters set the maximum number of times to send the trap notification and the time interval between each notification 2 www conteg com All rights reserved CONTEG 2012 c After clicking next you will be presented with the following screens Module enso Sensor Filter DARIO DA nA000259 FemperaturePortt v Module State LE Module V Dual Humidity V Dual Temperature v Temperature 2 Select your sensor 1 Select your module s y cement Gees 3 Click Next Status Action Filter SNMP Trap 1 High Critical 4 W SNMP Trap dal i 5 Select the name of the 4 Select status for more options D trap you just created holc 6 Click Finish On these screens you can select the parameters for when to send the SNMP trap notification In our example we have selected to bind the SNMP trap to the temperature sensor we have connected on port 1 The trap will be sent when the sensor reads a High
57. s on ramos conteg com j Can connect my unit via Wi Fi Yes you can connect the unit via Wi Fi Simply plug a USB dongle into the USB port on the rear of the unit You then need to configure your connection type and encryption key etc You do this from the web based interface in the settings tab and the connectivity option The dialogue for configuring the Wi Fi is shown below Wifi Network Wireless Adapter Status Not Found Device is not connected or cannot be Initialized Wireless Adapter On Off Default Interface Use this Interface as the Default Gateway Use DHCP Yes No IP Address 192 168 0 10 Subnet Mask 255 255 255 0 Gateway IP Address Domain Name Server Wireless SSID Encryption Mode Disabled 64bit WEP Link Status Not connected 0 Signal Strength 4 E k What is the Heartbeat message This setting is to have the RAMOS Ultra notify you it is still running You can be notified by either traps or by e mail Alive Trap settings Send Keep Alive Traps Default Off Select on if you want the system to send Alive Traps Destination enter the IP address of the server to send traps to Community SNMP community string Resend Interval mins The period of time between each keep alive trap Values range from 1 to 65535 minutes 49 www conteg com All rights reserved CONTEG 2012 I What is the network sniffer The Network Sniffer application can be used to capture network packets running to and fro
58. security features Confidentiality Encryption of packets to prevent snooping by an unauthorized source Integrity Message integrity to ensure that a packet has not been tampered with in transit Authentication to verify that the message is from a valid source Select ssl key File file name must be userkey pem Close www conteg com All rights reserved CONTEG 2012 Active Security Active Security C Allow Users to Acknowledge Alarms Active Securit z y Announce IF Address When Boots __ Reset In the Active Security section you can allow Users who are logged into the units web interface to Acknowledge alarms which is normally reserved only for the Administrator When the unit boots up it will announce the IP address that it has been configured with As an added security feature this announcement can be disabled in the above screen shot so that the IP address remains unknown The NAC or Network Access Control security feature Network Access Control Network Access Control Off 9 On Only allow access to the host below Access Policy Only deny access to the host below Address Allow List The NAC or Network Access Control feature allows you to restrict access to the web interface for only certain IP addresses or deny access to the web interface for only certain IP addresses 4 1 Setting up a sensor In this section we will now go through the basic set up of a sensor We will fo
59. t your IP address You will instead register a domain name for example myRamosUltra homeip com This will then automatically point your routers external IP address e g 278 67 04 09 This will require you to register the domain name and open an account with a DNS server provider f If you have set everything up correctly you will now be able to access your unit from anywhere in the world by simply pointing your web browser to your DNS address 10 FAQ a cannot see the temperature sensor displayed on summary page b Icannot access my unit s web based interface c What do my LED lights mean d have forgotten my unit s IP address e Ihave forgotten the password for my unit f Canluse DHCP to assign my units IP address g How do Iset up my routing table h How can I change my administrator password i What functions do different types of notifications provide j Can connect my unit via WiFi k Whatis the heartbeat message l What is the Network Sniffer 43 www conteg com All rights reserved CONTEG 2012 a cannot see the temperature sensor displayed on summary page If after logging in for the first time with the temperature sensor connected you may need to do the following Syslog Filters Sort by Date Number of display items per page 10 Advanced Filter i Display Log Level V Error Fa Warming W Notices splay Lag Type Sensor Log Notification Log Display Notification SMS Dis
60. this marker to re configure the thresholds After dragging the marker click save In the next screen shot you can see that this marker has been moved to make a new threshold and along with it the sensor status has changed Sensor Name Temperature Port 1 25 5 C LI h A e e Low Critical 0 7 15 22 High Critical High critical value is now Low Waring High Warning below current reading Low Critical Low Warning High Warning High Critical 0 T 15 22 Current Reading 25 5 C Status High Critical Sensor Currently _ Online If the marker is then dragged back to above the current reading temperature you should see the status returns to a normal condition again Note If this does not happen straight away press your browsers refresh button Status is now showing critical Sensor Name Temperature Port 1 High critical value set to above current reading h h 33 41 High Critical ah dh Low Critical 0 4 Low Warning High Warning Low Critical Low Warning High Warning High Critical 0 4 33 41 Current Reading 25 0 C nt Readin Status Normal Sensor Currently _ Online Status returns to normal If you wish to take a sensor offline then click on the sensor currently button These will offline the sensor without the need for you to physically unplug it 20 www conteg com All rights reserved CONTEG 2012 Current Reading 25 0 C Status Normal Sensor Current E Online Cu
61. tification Access Control Settings Summary Setting Sensor Information Layout Setting Host Name Type Sensor Name Reading Status Sensor Filters Main Module Virtual Sensors Temperature on RAMOS Mini 73 59 Normal Temperature Array Temperature Array Port 2 1 24 5 C Normal EMI Temperature Array Temperature Array Port 2 2 24 5 C Normal Advanced Filter Temperature Array Temperature Array Port 2 3 24 5 C Normal Display Status Temperature Temperature Port 4 24 5 C Normal Display Sensor Type e z Di Dry contact I O Port 3 m rau user Dry contact I O Dry contact I O Port 3 4 20 mAmp 4 20 mAmp Port 1 0 1 kPa Normal Search t RAMOS ULTRA EX 0A000858 Module RAMOS ULTRA EX 0A000858 _ Apply Filter Clear Filter Sensors status will be reloaded in 05 secs System Log 0 messages to Select Settings tab A Reload S Interval e oad Sensor Interval Be Apply g Syslog Filters y Requesting data 7 u e Click on Ethernet network from the list on the left frame of the page cam 7 CONTEG RAMOS to complete your networ ULTRA Location System Location Current System Time 21 01 2000 19 07 13 Summary LETS Sensors Notification Access Control Settings Applications Help Ethernet Network Setup Default Interface vV Use this Interface as the Default Gateway M H Hann uu Use DHCP Yes No General 1 Click on Connectivity ea ress NENE 2 Enter IP address Ethernet Network Subnet Mask 255 255 255 0 2 Clic
62. ur unit s IP address is the default 192 168 0 100 Your computer s IP address is 192 168 0 200 Your router s IP address is 192 168 0 300 b b To find out your routers external IP address go to www seemyipaddress com Let s imagine your router s external IP address is 278 67 04 09 c You now need to setup port forwarding on your router This varies depending on your routers model Generally you need to point your browser to your router s IP address in this case 192 168 0 300 This will then allow you to log into your router s administration interface You can find how to go about doing this for your router on www portforward com 42 www conteg com All rights reserved CONTEG 2012 For example of how to do this for a commonly used router follow this link http www portforward com english routers port forwarding Linksys WRT54G HTTP htm You need to setup your routers HTTP forwarding to port 80 This will then mean that when you access your router using the external IP address you will be forwarded to your unit s internal IP address d Totest this open your web browser and go to your external IP address in our example 278 67 04 09 If you using a dynamic IP address its best to check it again before doing this as it may have changed since the start of this tutorial e Tomake this easier you could use a dynamic DNS Dynamic Name Server This means you no longer need to remember IP addresses or use www seemyipaddress com to find ou
63. will be reloaded in 03 secs Reload Sensor Interval 10 secs Apply Syslog Filters The temperature sensor should be listed along with its current reading and status If this is not shown please see refer to the FAQ This summary page allows you to quickly see which sensors are connected their status view the system log and also view footage from any connected cameras We will now go through some of the tools the web based interface provides for getting feedback from the sensors c Now click on the temperature sensors name indicated in previous screen shot This will bring you to the following page the sensors page G CONTEG RAMIS to complete your networ ULTRA Location System Location Current System Time 02 07 2012 16 07 35 Summary LETS Sensors Notification Access Control Settings Applications Help Sensor Settings Sensors Menu 1 2 3 4 5 6 T 8 Auto Sense E Auto Sense Auto Sense E Auto Sense _ Auto Sense _ Auto Sense _ E Auto Sense Auto Sense E Auto Sense L e e e Expansion Boards Status amp Power Meter Online e d E Virtual Sensors M m mm id id SNMP OID gp NIC NIC NIC NIC This page shows the sensor ports and their respective status and state Normal Settings Advanced Settings Continuous Time Settings Minimum Time Settings Click on a port to display or configure its settings oa seein rte eme Name of Sensor Roan 25 5 C One way to r