8209 User Manual - Sealevel Systems, Inc
Contents
1. You should have a new SealO 8209 in the Seal O Device heading indicating the installation was successful The SEALINK DIO 16 is now ready for use Sealevel Systems Inc 4 SEAINKDIO 16 User Manual Programming the SEALINK DIO 16 Sealevel s Seal O software is provided to assist in the development of reliable applications for the Sealevel Systems family of digital I O adapters Included on the Seal O CD are driver functions for use in accessing the I O as well as helpful samples and utilities Programming for Windows The Seal O API Application Programmer Interface provides a variety of useful high level function calls implemented in a Windows dynamic link library DLL The API is defined in the help file Start Programs SealO SealO Help under Application Programmers Interface This help file also includes detailed information dealing with installation removal of the software and information about latency logic states and device configuration For C language programmers we recommend using the API to access the SEALINK DIO 16 If you are programming in Visual Basic using the ActiveX control included with Seal O is advised Samples and Utilities A variety of sample programs and utilities both executable and source code are included with Seal O Further documentation on these samples can be found by selecting Start Programs SealO Sample Application Description Information about where the files are phys
2. Home page on the Internet Our home page address is http www sealevel com The latest software updates and newest manuals are available via our FTP site that can be accessed from our home page Technical support is available Monday to Friday from 8 00 a m to 5 00 p m eastern time Technical support can be reached at 864 843 4343 RETURN AUTHORIZATION MUST BE OBTAINED FROM SEALEVEL SYSTEMS BEFORE RETURNED MERCHANDISE WILL BE ACCEPTED AUTHORIZATION CAN BE OBTAINED BY CALLING SEALEVEL SYSTEMS AND REQUESTING A RETURN MERCHANDISE AUTHORIZATION RMA NUMBER Sealevel Systems Inc 11 SEAUNKDIO 16 User Manual Appendix C Silk Screen 8209 PCB SE EE LE Oe o E O ee ER tia E SE 28 g o O Sealevel Systems Inc 122 SEALINKDIO 16 User Manual Bac BE ci8 Appendix D Compliance Notices Federal Communications Commission Statement FCC This equipment has been tested and found to comply with the limits for Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment
3. Pin Assignments Removable Terminal Block 0 1 aa 10 11 Port A Input Bit Port A Terminals Side Panel View Port B Sealevel Systems Inc 7 SEAU NK DIO 16 User Manual Electrical Characteristics Features Specifications Sealevel Systems Inc 8 SPST Reed relays Eight optically isolated inputs Removable screw terminals Powered by USB port Input Ports Turn On Current Isolator Diode Drop Resistor Power Max Maximum Input Range Output Relays Contact Max Power Rating Contact Voltage Maximum Contact Current Maximum Contact Resistance Initial Rated Life e Low Load e Maximum Load m Contact Speed e Operate e Release e Bounce m Maximum Operating Speed Temperature Range m Operating m Storage Power Requirements m 5VDC 500mA Manufacturing ImA 1 1 VDC 5 W 5 30 VDC VAC 10 W 100 VDC VAC 5 A AC DC RMS 15 Q 200 Million Closures 100 Million Closures 5 mS 5 mS 5 mS 600 Hz 0 C 70 C 50 C 105 C All Sealevel Systems Printed Circuit boards are built to UL 94V0 rating and are 100 electrically tested These printed circuit boards are solder mask over bare copper or solder mask over tin nickel SEALINKDIO 16 User Manual Example Circuits Input Circuit ngut Input Port Bit Common Output Circuit Output Common Output Port Bit Relay Seale
4. select the Run this program from its current location or Open option Follow the information presented on the screens that follow A screen may appear with the declaration The publisher cannot be determined due to the problems below Authenticode signature not found Please select the Yes button and proceed with the installation This declaration simply means that the Operating System is not aware of the driver being loaded It will not cause any harm to your system During setup the user may specify installation directories and other preferred configurations This program also adds entries to the system registry that are necessary for specifying the operating parameters for each driver An uninstall option is also included to remove all registry INI file entries from the system Windows NT Note Windows NT is not USB aware and thus cannot support the SeaLINK DIO 16 Sealevel Systems Inc 3 SEALINK DIO 16 User Manual Physical Installation The SeaLINK DIO 16 can be installed in any open USB port Do not plug the unit into a USB port until the software has been fully installed 1 Simply connect the SeaLINK DIO 16 to your USB port with the supplied cable The software drivers installed during setup will automatically recognize and configure the device You should see one or more New Hardware Found windows indicating the actual device being created Next view your system s Device Manager
5. to offer this warranty due to our control of manufacturing quality and the historically high reliability of our products in the field Sealevel products are designed and manufactured at its Liberty South Carolina facility allowing direct control over product development production burn in and testing Sealevel Systems Inc hereafter Sealevel warrants that the Product shall conform to and perform in accordance with published technical specifications and shall be free of defects in materials and workmanship for life In the event of failure Sealevel will repair or replace the product at Sealevel s sole discretion Failures resulting from misapplication or misuse of the Product failure to adhere to any specifications or instructions or failure resulting from neglect or abuse are not covered under this warranty Warranty service is obtained by delivering the Product to Sealevel and providing proof of purchase Return authorization must be obtained from Sealevel Systems before returned merchandise will be accepted Authorization is obtained by calling Sealevel Systems and requesting a Return Merchandise Authorization RMA number The Customer agrees to insure the Product or assume the risk of loss or damage in transit to prepay shipping charges to Sealevel and to use the original shipping container or equivalent Warranty is valid only for original purchaser and is not transferable Sealevel Systems assumes no liability for any damages lo
6. 6 OUTPUT PORTS REED RELAYS aa SR at a 6 PIN ASSIGNMENTS REMOVABLE TERMINAL BLOCK ssessesseseesssseesssssresssseresssereessoseesssseessssrree 7 ELECTRICAL CHARACTERISTICS e esesosososososoeseseoeoeoeseoeseceseseseseseseseseseseoesesesesesesesesesse 8 FEATURES nu M me in Rat AR Sa ne nn te Re A Sl 8 SPECIFICATIONS cus at a marne AR a dad aa ca induc aoe ead eS en nr en PR ae Sad Ee 8 EXAMPLE CIRCUITS scsscscsccscccccscdccscccssc sccsseceseccescescassdcesccdsscdccasdacesoccesdescessdcesecesoccscasdsdedocoatsvacs 9 APPENDIX A TROUBLESHOOTING 20 00 00 ccccccccccccccccscccccccccccscscscccscccssscssscscscssscsescccceees 10 APPENDIX B HOW TO GET ASSISTANCE cccccccscscscccscscscscccccscssssscscscscscscssscscscccceses 11 APPENDIX C SILK SCREEN 8209 PCB e eoeoeoeoeoeoeoeoeoeseoeseseseoeoeoesesososososososesosesesesesse 12 APPENDIX D COMPLIANCE NOTICES 2 0 0 0 ccccscssscscscscscscccscscscscscscscscscccceccccscccseseseees 13 FEDERAL COMMUNICATIONS COMMISSION STATEMENT ccssssesseccccccccssesesescccccssesseseecescesseees 13 WARRANDY seccccccescsccesscecccctesccccdesceccsscecececessescuessescscucectescessesececesccncues moon ere sance sosesscascesceevesccsess 14 Sealevel Systems Inc SEAL NK DIO 16 User Manual SL9017 Revision 7 2006 Introduction The SeaLINK DIO 16 provides 8 Reed relays that can latch power data or other electronic signals for control applications and 8 optically isolated inputs to al
7. All items can be purchased from our website http www sealevel com or by calling 864 843 4343 DIN Rail Clips Part Number DR102 A pair of brackets clips and hardware necessary for DIN rail mounting the SeaLINK DIO 16 a 2U 19 Rack Tray Part Number RK2U Standard 2U rack tray for supporting SeaLINK and other devices Clamp for Rack Tray Part Number RK CLAMP Metal clamp and necessary hardware to secure SeaLINK or other devices to the RK2U rack tray High Speed USB 2 0 4 Port Hub Part Number HUB4 AC powered 4 port USB hub AC adapter and USB cable High Speed USB 2 0 7 Port Hub Part Number HUB7 AC powered 7 port USB hub AC adapter and USB cable Sealevel Systems Inc 2 SEAL NK DO 16 User Manual Software Installation Windows 98 ME 2000 XP Installation Important Do not connect the SeaLINK DIO 16 adapter to the host USB device until the software has been fully installed 1 2 3 Start Windows Insert the Sealevel Systems CD in to your CD drive If Auto Start is enabled for this drive the software will automatically launch Otherwise point your browser to the Index htm on the root directory of the CD Select Install Software Select the Part Number for your adapter from the listing Select Windows 98 ME 2000 XP The setup file will automatically detect the operating environment and install the proper components Next depending on your browser
8. SeaLINK DIO 16 User Manual Part Number 8209 SEALEVEL EMS INCORPORATED www sealevel com PO Box 830 Liberty SC 29657 864 843 4343 Table of Contents INTRODUCTION sescccssdeccciccicccccsssscscececccsccesteacceaedecesessecosceaecsccadsocoasssoedeceaesossdecenesscadecsdoSscesedecsacees 1 OTHER SEALEVEL USB DIGITAL I O PRODUCTS 0 cccccccccccccccsesessscscccccccssnsssececcsccesssaeassceceesseees 1 BEFORE YOU GET STARTED ssesosssssssssssssssssssssssssssssssssssssososssosssssssososssssssososososossssssssso 2 WHAT S INCLUDED 24515585 dod Seeded Salts dane AR ae et ce Dsl alsa insu a States 2 OPTONAL TEM Sus cat Run ann a A E UN Si Re RSA Un NS un ty 2 SOFTWARE INSTALLATION ccccdisicscedibioceesteidsccticiotccdeetctecciscotecsloncesecdbcesceceadesoscecdedsoscandsoccdace 3 WINDOWS 98 ME 2000 XP INSTALLATION ccsssscsccccccccsssssssscccccecessesssesceccsssssseeesescescessseuenens 3 PHYSICAL INSTALLATION iivsssssscccsccccscsssccasseuscssecossscsccossccsccosssdaccesscceccossscdcceseccsesoascsaccesscsseses 4 PROGRAMMING THE SEALINK DIO 16 ccccccscscscscscssscssscscscscscscccccscccccscccscssscscssscseses 5 PROGRAMMING FOR WINDOWG cccccccccccscsssssececcccccsessssecsccecesseusssesesccscssssuusussesccessessuueaseeceeseeaes 5 DIGITAE T OvINTERFAGE so csdesiccc duds E AE A des a de natale de es tte 5 SERTAL STRING HER Re ee na int tage de na cost o ab ana E E E 5 INPUT PORTE eS PR dan ne sens tes ere etre dent ae se
9. ically stored on your disk is also included in this same file Digital 1 0 Interface Serial String The SeaLINK DIO 16 provides one parallel input port and one parallel reed relay output port The ports are organized as ports and B Port is an input port interfaced to optically isolated inputs while port B is the relay output port The SeaLINK DIO 16 is a line powered device requiring a USB port capable of sourcing 500 mA Each device has an eight digit alphanumeric serial string stored in non volatile memory On the Windows platforms this number is used to give each unit a separate identity This identity allows the device to be moved to any USB port or hub port on your computer while retaining its device number If a device becomes damaged and is replaced the new device should be given the same serial string as the device it is replacing This string is stored in an EEPROM along with other critical information This EEPROM is read during enumeration The device should not be unplugged during its enumeration due to remote possibility that the data in the EEPROM could be corrupted if power is removed during a read write cycle to the EEPROM Enumeration is complete when the LED is lit The control panel utility provides the capability to read or modify this string However setting the same string for two units connected to the same computer will cause the second unit to fail enumeration and make it invisible to the operating system Sh
10. in a residential area is likely to cause harmful interference in such case the user will be required to correct the interference at the users expense EMC Directive Statement CE Products bearing the CE Label fulfill the requirements of the EMC directive 89 336 EEC and of the low voltage directive 73 23 EEC issued by the European Commission To obey these directives the following European standards must be met EN55022 Class A Limits and methods of measurement of radio interference characteristics of information technology equipment EN55024 Information technology equipment Immunity characteristics Limits and methods of measurement EN60950 IEC950 Safety of information technology equipment including electrical business equipment Warning This is a Class A Product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures to prevent or correct the interference Always use cabling provided with this product if possible If no cable is provided or if an alternate cable is required use high quality shielded cabling to maintain compliance with FCC EMC directives Sealevel Systems Inc 13 SEAU NK DIO 16 User Manual Warranty WARRANTY Trademarks Sealevel s commitment to providing the best I O solutions is reflected in the Lifetime Warranty that is standard on all Sealevel manufactured products We are able
11. low monitoring of off board switch closures relays or for any other general purpose monitoring needs The adapter is USB 1 1 compliant The SEALINK DIO 16 is designed to be used under Windows 98 ME 2000 XP The Seal O API Application Programmer Interface included on CD with the SEALINK DIO 16 provides a variety of useful high level function calls implemented in a Windows dynamic link library DLL This API gives access to the SeaLINK DIO 16 I O from Windows based platforms such as Visual C In addition to the API Seal O includes an ActiveX control along with sample code and utilities to simplify software development Other Sealevel USB Digital 1 0 Products SeaLINK PLC 16 P N 8206 8 Form C Relays 8 Opto isolated Inputs SeaLINK ISO 16 P N 8207 16 Opto isolated Inputs SeaLINK REL 16 P N 8208 16 Reed Relay Outputs SeaLINK PIO 48 P N 8203 48 TTL Inputs Outputs SeaLINK PIO 96 P N 8205 96 TTL Inputs Outputs Sealevel Systems Inc 1 SEAUNKDIO 16 User Manual Before You Get Started What s Included The SEALINK DIO 16 is shipped with the following items If any of these items is missing or damaged please contact Sealevel for replacement SEALINK DIO 16 Adapter USB A to B Cable Part number CA179 Sealevel Seal O Software CD Optional Items Depending upon your application you are likely to find one or more of the following items useful for interfacing the SEALINK DIO 16 to real world signals
12. ould this occur unplug one unit and set the serial string for the other unit to a different string Sealevel Systems Inc 5 SEAU NK DIO 16 User Manual Input Port Port A is an eight bit input port connected to optically isolated input sensors Each sensor can be used to interface a voltage input and then sense whether the voltage is on or off Each sensor is isolated with respect to a common ground from every other sensor and also isolated with respect to the host PC ground This means that signals such as low level AC line voltage motor servo voltage and control relay signals can be sensed or read by the PC without the risk of damage due to ground loops or ground faults Each sensor input pair has a current limiting resistor 2 7K ohm that is used to limit the input current to the opto isolator The opto isolator has two back to back diodes internally This allows AC or DC signals to be sensed regardless of polarity When the applied voltage is high enough to cause the led in the opto isolator to turn on the output of the opto isolator goes low 0 volts and the signal is read as a low logic level binary 0 by the PC When the input signal is too low to turn on the opto isolator the output goes high and the port bit is read by the PC as a high logic level binary 1 The opto isolator requires approximately ImA to turn on The maximum input current is 50mA There are two things to consider when selecting the input re
13. sistor The first is turn on voltage for the circuit to sense and second is the maximum input voltage Maximum input voltage must not provide too much power to the input resistor and must also not overdrive the opto isolator input current specification The following formulas apply Turn on Voltage diode drop turn on current x resistance Ex 1 1 003 x R Input Current input voltage 1 1V resistor value Maximum voltage 1 1 square root of 25 resistor value The following table shows the ranges associated with the resistor Input Range Max Current 2 1KO 5 30V Note The turn off voltage for all resistors is less than 1V i Because through hole resistors are utilized they cannot be easily replaced If modification is necessary Sealevel can do this for an additional charge Important The input circuits are not intended for monitoring 120 volt AC circuits In addition to being too high a voltage for the circuits it is dangerous to have that high a voltage on the card Output Ports Reed Relays Reed relays provide very high quality long life low power dry contact switch closures Reed relays are not suited for high current applications or inductive loads The relays are normally open and close when energized Writing a logic value of one or zero will change the state Refer to the Application Programmers Interface for more information Sealevel Systems Inc 6 SEAU NK DIO 16 User Manual
14. st profits lost savings or any other incidental or consequential damage resulting from the use misuse of or inability to use this product Sealevel Systems will not be liable for any claim made by any other related party This warranty applies to Sealevel manufactured Product Product purchased through Sealevel but manufactured by a third party will retain the original manufacturer s warranty Sealevel Systems Incorporated 2779 Greenville Highway P O Box 830 Liberty SC 24857 USA 864 843 4343 FAX 864 843 3067 www sealevel com email support O sealevel com Technical Support is available Monday Friday from 8 a m to 5 p m Eastern time Sealevel Systems Incorporated acknowledges that all trademarks referenced in this manual are the service mark trademark or registered trademark of the respective company O Sealevel Systems Inc 14 SEALI NK DIO 16 User Manual
15. vel Systems Inc 9 SEAU NK DIO 16 User Manual Appendix A Troubleshooting Following these simple steps can eliminate most common problems 1 Install software first After installing the software then proceed to adding the hardware This places the required installation files in the correct locations Read this manual thoroughly before attempting to install the adapter in your system Use Device Manager under Windows to verify proper installation Use the SealO Control Panel applet or the Device Manager s property page for card identification and configuration If these steps do not solve your problem please call Sealevel Systems Technical Support 864 843 4343 Our technical support is free and available from 8 00AM 5 00PM Eastern Time Monday through Friday For email support contact support sealevel com Sealevel Systems Inc 10 SEAUNKDIO 16 User Manual Appendix B How To Get Assistance Begin by reading through the Trouble Shooting Guide in Appendix A If assistance is still needed please see below When calling for technical assistance please have your user manual and current adapter settings If possible please have the adapter installed in a computer ready to run diagnostics Sealevel Systems provides an FAQ section on its web site Please refer to this to answer many common questions This section can be found at http www sealevel com fag asp Sealevel Systems maintains a
Download Pdf Manuals
Related Search
Related Contents
Istruzioni d`uso Bilancia prezzatrice KERN RPB-N warnung - Alliance Laundry Systems Cooper Lighting L1525 User's Manual Mode d`emploi COTTON FIX BASIC INPUT OUTPUT SYSTEM KLUWER ARBITRATION.cdr OPERATING INSTRUCTIONS MANUAL FOR KMS MF 國議一断)用 医薬品 - 医薬品医療機器総合機構 User Manual - Universal Fibre Optics 小電力の無線システムの高度化に必要な技術的条件 Copyright © All rights reserved.