Home
User Guide Laboratory Shaker
Contents
1. Life Sciences User Guide Laboratory Shaker Part Number 4821A 115 Volt CE Part Number 4822A 230 Volt CE Filtration Separation Solution su Table of Contents DEsScrpUOM csfas sanr e a r Ee aE ae aeaa arar aaa 3 General IMPOPMALON caccceis tecstiecsseataticas cccvenscasseninetecsssaruessesunensaascacuenntes coanecseestenseadscesuensenedtvecteanasactaandardearereds 3 Ordening INFOMMALNO Ncisiescedecedececciccceecescecctccetccecece detec cccescedicecdaetecececs daidai idd aaiae asiasanat diasaan 3 SPE CHIGAUONMS scipgestscscpececeswsypcs seca aa stad lapses Sincapex A AA EA AAR 3 Installation of the Laboratory Shaker cssicecccccccscecccccestectecansceececcnatececccesetececemmuedcedsnauenteceneanteececeauneccedeeaueeeed 4 iti daller olp toate glU Cy aereeenerrererenr Seer a Sere creer rrrerrreererer tree TPerrerrertpre reer Cree error er Trrercr ere rreccerree 4 WAIL HVAC zo sed craneae ea raaa a e aa racy stg yeadees a Eaa aa a EAEE 6 Replacement PariS eviccccccvesiessecas seccwsristessviustansanscneiies ecacevadsetcuaanssscaccenetes cau esancauebavaessecrteasdsuaubsnsawasrensearerssenscued 6 MAN gs Sec ccaec ce cecteee c2ccuscessccece A 7 Note The procedures herein are intended only as a guide Users should always verify product performance with their specific applications under actual use conditions If you have questions about the information presented in this guide please contact Pall Life Sciences Technical Service
2. RESUME EXIT Paused Timed Run Menu Selecting Exit will disengage the Shaker and return the user to the main menu 1 RUN 2 TIMED RUN Main Menu Maintenance Before removing the casing always be sure the Laboratory Shaker is unplugged The manipulation of the A internal electronic circuits of the apparatus by unauthorized personnel can cause irreparable damage to the apparatus Cleaning Cleaning of plastic Use alcohol with cotton cloth Painted metal case Use damp cloth and mild soap Replacement Parts Part Number Description 89051 Clamp with extension collar 6 Life Sciences WARNING Employment of the products in applications not specified or failure to follow all instructions contained in this product information insert may result in improper functioning of the product personal injury or damage to property or the product See Statement of Warranty in our most recent catalog ATTENTION Lutilisation de nos produits dans des applications pour lesquelles ils ne sont pas sp cifi s ou le non respect du mode d emploi qui figure sur ce document peut entrainer un disfonctionnement du produit endommager le produit ou d autres biens mat riels ou repr senter un risque pour l utilisateur Se referer a la clause de garantie de notre catalogue le plus recent ACHTUNG Der Einsatz dieses Produktes in Anwendungen fur die es nicht spezifiziert ist oder das Nichtbeachten einiger in dieser Bedienungsanleitu
3. 2 Life Sciences Description e Designed to hold capsule filters in the horizontal orientation for elution of particulate and organisms e Easily detachable arms equipped with eight cork lined clamps e Process up to eight Envirochek Sampling Capsules at one time e Programmable digital speed and timer General Information f 1 Handle the parcel with care Unpack and check that the contents coincide with the packing list If any part is damaged or missing please advise the distributor immediately 2 Do not install or use the equipment without first reading the Product Information Insert 8 The manual should be made available for all users 4 If you have any inquiries please contact your supplier or Pall Life Sciences Technical Service 5 Do not use the apparatus with liquids which can give off vapors capable of making explosive mixtures Ordering Information Laboratory Shaker Part Number Description Pkg 4821A 115V 1 pkg 4822A 230V 1 pkg Packing List The standard equipment consists of the following components Product Qty Laboratory Shaker 115 or 230 1 Arms 2 Clamps 8 Power Cord 115V 230V 1 2 Product Information Insert Allen Wrenches 3 mm 5 32 3 32 3 Specifications Dimensions Height 37 21 cm Length 82 21 cm Width 34 72 cm Maximum Capacity 4 kg 8 8 Ib Oscillations Minute 100 900 RPM Power Consumption 150 W www pall com lab Weight PN 4821A 40 kG 88 2 Ib PN
4. 4822A 41 kG 90 4 Ib Voltage PN 4821A 115V 50 60 Hz PN 4822A 230V 50 60 Hz Installation of the Laboratory Shaker 1 Place the apparatus on a level surface with sufficient stability to resist its own vibrations 2 Fit the arms with clamps vertical at the shaker side shaft so that the screws tighten against the side of the shaft 3 If the shaker moves during operation this can be alleviated by putting a piece of cushioned rubber between the table and the shaker CAUTIONI IMPORTANT FOR YOUR SAFETY Be sure that the voltage supply is the same as the one indicated on the characteristics plate Do not use the apparatus to shake products capable of making an explosive mixture Do not use the apparatus if it is not grounded Instructions for Use Control Panel 1 Power Switch 2 Display time speed 3 D Pad 4 Enter button 5 Cursor indicator 5 FRONT PANEL DISPLAY Starting Up 1 Plug Laboratory Shaker into 115V 50 60 Hz or 230V 50 60 Hz line as indicated on the characteristics plate located on the back of the instrument 2 Turn on the Power switch located on the front of the instrument Follow steps outlined below for Continuous Operation or Timed Operation 4 Life Sciences Continuous Operation Example To run Laboratory Shaker in continuous non timed operation move the Cursor using the D Pad to the 1 Run from the Main Menu and press the Enter button The Shaker will engage at the last remembered R
5. PM RUN TIME 00 00 01 RPM 100 PAUSE EXIT Run Menu The RPM can be adjusted by increments of 50 using the D Pad The clock will keep track of the total run time Selecting Pause will stop the clock and disengage the Shaker PAUSE RUN TIME 00 00 01 RPM 100 RESUME EXIT Paused Run Menu Selecting Resume will start the clock count and re engage the Shaker Selecting Exit will disengage the Shaker and return the user to the Main Menu 1 RUN 2 TIMED RUN Main Menu Timed Operation Example To run the Laboratory Shaker in timed run operation select the 2 Timed Run from the Main Menu and press the green button to navigate to the Timed Run Set up Menu TIMED RUN SETUP RUN TIME HR MN SC RPM 100 START EXIT Timed Run Set up Menu The first line will display Run Time which controls the total run time before the Shaker stops Hours minutes and seconds can be selected using the left and right arrows on the D Pad Once the time has been set press the Enter button The second line RPM can be adjusted by increments of 50 using the D Pad Once the pa rameters have been set select Start and press Enter to begin the timed run REMAINING 99 59 59 RPM 960 PAUSE EXIT Timed Run Menu www pall com lab 5 Selecting Pause will stop the clock and disengage the Shaker Selecting Resume will start the clock count down and re engage the Shaker PAUSE REMAINING 99 59 59 RPM 960
6. nd Italy Japan Korea Malaysia New Zealand Norway Philippines Poland Russia Singapore South Africa Spain Sweden Switzerland Taiwan Thailand United Kingdom and Vietnam Distributors in all major industrial areas of the world To locate the Pall office or distributor nearest you visit www pall com contact The information provided in this literature was reviewed for accuracy at the time of publica tion Product data may be subject to change without notice For current information consult your local Pall distributor or contact Pall directly 2015 Pall Corporation Pall and Envirochek are trademarks of Pall Corporation indicates a trademark registered in the USA ENABLING A GREENER FUTURE and Filtration Separation Solution are service marks of Pall Corporation Filtration Separation Solution sm 2 15 PDF GN14 1031 PN91048 Rev B
7. ng gegebenen Hinweise Kann zu einem schlechteren Ergebnis oder Zerst rung des Produktes oder anderer Dinge oder gar zu Verletzungen f hren Beachten Sie auch unsere Garantiebedingungen im aktuellen Katalog ADVERTENCIA El uso de este producto en applicaciones no especificadas o el no considerar las instrucciones indicadas en la hoja de informacion del producto puede ocasionar un mal funcionamiento del producto da os en las instala ciones o en el producto y riesgo para el personal del laboratorio Consulte el apartado de Garant a en nuestro ultimo catalogo ATTENZIONE Limpiego dei prodotti in applicazioni non specificate o il manacato rispetto di tutte le istruzioni contenute nel presente bollettino tecnico potrebbero portare ad un utilizzo improprio del prodotto ferire gli opertori o dan naeggiare le caratteristiche del prodotto stesso Consultare la dichiarazione di garanzia pubblicata nel nostro piu recente catalogo 2 ENABLING A GREENER To see how Pall is helping enable a greener safer and more sustainable FUTURE future visit www pall com green Life Sciences Visit us on the Web at www pall com lab E mail us at LabCustomerSupport pall com Pall Life Sciences 25 Harbor Park Drive Port Washington New York 11050 International Offices Pall Corporation has offices and plants throughout the world in Argentina Australia Austria Belgium Brazil Canada China France Germany India Indonesia Irela