1. MODPARK Parking System ANJEL Fs 1 2 Installation AB 25 AB 40 a When you prepare the concrete foundation lay enough cable or a plastic duct for the cable you need The foundation must be at least 800 mm deep with a horizontal surface 500 x 550 mm b Using the template you can either incorporate bolts in the foundation or drill holes in the hardened concrete for heavy duty fixings The door side of the template must face towards the road on which the barrier will be closing c As an alternative 2 U profile clamping irons are delivered with the barrier This gives more flexibility in positioning the fastening points and allows the barrier to be aligned exactly as required Attention The barrier is closed when shipped The door faces towards the road d Secure the barrier on the foundation e Connect the boom holder to the shaft Tighten all screws the top ones first with 35 Nm The enclosed nuts and bolts are a predetermined breaking point and should only be replaced with the same Bolt M 8 x 45 ISO 4762 12 9 Nut hexagonal M 8 ISO 4032 5 2 Release bolt Boom holder gt Sar ee gt a Shaft Release lever f Emergency release during current failure etc Pull the lever with the red end which is behind the access panel The boom can then be raised manually To engage the boom again pull the lever and pull th
2. 3 The magnet switches on again when Ad the barrier reaches the limit switch at i h the closed position A2 21 14 14 1 2 S top bottom bottom top N Rx Magnet We reserve the right to make technical improvements without prior notice T Dokumentation Modpark Peripherie Schranken Englisch AB25 80 M063 En2002V 11 DOC Page 20 of 22 En IR AUT TOMATISIERUNG UND SYSTEMTECHNIK Manual Barriers MODPARK Parking System ANJEL 13 General notes of safety These operating instructions must be available on site at all times It should be read thoroughly by all persons who use or service the appliances Improper usage or servicing or ignoring the operating instructions can be a source of danger for persons or result in material damage If the meaning of any part of these instructions isn t clear then please contact ASYTEC GmbH before you use the appliance This applies to all setup procedures fault finding disposal of material care and servicing of the appliance The accident prevention regulations and applicable technical regulations e g safety or electrical and environment protection regulations of the country in which the appliance is used also apply All repairs on the appliances must be carried out by qualified persons ASYTEC GmbH accepts no liability for damage which is caused by using the appliance for purposes other than those for which it is built ASYTEC GmbH cannot recognise every possible source of dang
3. and secure the bearing with two M5x60 hex socket screws h Fit the bearing 9 between the side plates 3 with a long brass bush and an M8 x 50 bolt j Fit the connecting rod 5 with a long brass bush between the side plates 3 k Mount the boom on the barrier l Push the connecting rod into the bearing 8 m Hold the second part of the boom horizontal and clamp the connecting rod with the grub screws 15 n Pull out the emergency release bolt and push the boom into the vertical o Align the horizontal part by moving the pivot screw 13 up or down p Check that all screws are tight q Cut off the superfluous part of the connecting rod Folding boom for AB 50 AB 80 upon inquiry We reserve the right to make technical improvements without prior notice T Dokumentation Modpark Peripherie Schranken Englisch AB25 80 M063 En2002V 11 DOC Page 17 of 22 MODPARK Parking System ASTE mo W MeH Manual Barriers F R AUTOMATISIERUNG UND SYSTEMTECHNIK lq gt L1 lt 4 rid gt L3 max 1500 mm 830 lel oO N 105 horizontal boom Housing 8 dis a 14 O o o 5 a Su o of amp gt 9 u o o 5 os 2 o 2
4. AGY dw Dve FUR AUTOMATISIERUNG UND SYSTEMTECHNIK BTS2 Push button stop 2 n c V15 7 X1 8u When the contact BTS2 is open the barrier stops Stored signals are erased Automatic closure is blocked until the next signal LS Photo cell n c V15 8 X1 9u When the photo cell reports an obstacle the barrier cannot be closed During the opening of the barrier an existing obstacle is not report When an obstacle is reported during closing the barrier stops and reverses Additional functions of the photo cell depend on operating mode photo cell closing automatic and photo cell test 3 2 Further connections Photo cell 24V V4 4 X1 260 Power supply for photo cell transmitter 24V only for photo cell test transmitter OV V12 1 X1 26u Ground for photo cell transmitter OV only for photo cell test Uext 24V V12 2 xX1 1u 24Vdc stabilised for external equipment Max 500 mA for V12 1 V12 2 Uext 12V V12 3 X1 33u 14Vdc stabilised for external equipment Max 500 mA Gnd V12 4 X1 2u Ground for Uext external equipment Display V15 12 X1 110 Display barrier open The contact V15 12 is connected with the barrier open contact V15 14 when the barrier is open The contact will be closed when the green light is lit Maximum permissable 24V 1A Display V15 13 X1 120 Display barrier closed The contact V15 13 is connected with the barrier closed contact V15 14 when the barrier is open The
5. setup 0 s up to 300 s 4 4 Reversal on hitting obstacles S5 REV When learning the running time during the setup the torque power for the reversing on obstruction is determined When the barrier boom hits an obstacle during closing and blocks the controller stops the movement or gives an open signal S5 off The closing boom stops when it hits an obstacle and re opens immediately S5 on The closing boom stops when it hits an obstacle and only moves when a new signal is received 4 5 Counting S6 Z HL The signals open and close are counted by the controller S6 off No counting The barrier closes after one signal to close even after two signals to open S6 on Counting is activated The barrier closes after two signals to close if there were two consecutive opening signals 4 6 Reversal during opening S7 SZ When a close signal is received during opening the barrier will either open completely and then close or the barrier closes immediately S7 off The barrier always opens completely before reacting to a signal to close S7 on The opening barrier reverses immediately when it receives a signal to close 4 7 Automatic closure by photo cell S8 LSA The photo cell always gives a signal to close when the obstacle is not longer present S8 off Automatic closure by photo cell is not activated The closing function by loop B3 1 is not applicable S8 on When an obstacle is not longer present the ba
6. test The transmitter is inactive but the receiver does not signal an obstacle 7 x flashing An error occurred during learning of the torque power for the reversing on obstacle Either the controller the motor or the capacitor of the motor are faulty Check the above and repeat the learning of the running time If the error still exists the controller is faulty 8 x flashing The EEPROM has lost the data Repeat the learning of the running time If the error still exists the controller is faulty 9 x flashing The EEPROM is faulty 10 x flashing The controller has detected a fault in the redundant detection of the stop contact The controller is faulty 11 x flashing One of the motor relays has not switched off The controller is faulty 12 x flashing The controller detects that the Triac has not switched off The controller is faulty Attention You may use the service device ZS701 to read the error memory of the controller We reserve the right to make technical improvements without prior notice T Dokumentation Modpark Peripherie Schranken Englisch AB25 80 M063 En2002V 11 DOC Page 14 of 22 Manual Barriers IR AUT TOMATISIERUNG UND SYSTEMTECHNIK MODPARK Parking System ANJEL Fs 10 Maintenance 10 1 Maintenance AB 25 AB 40 The maintenance intervals must be decided individually as they are dependent on the frequency of use We recommend maintenance at least once every six months Chec
7. the relay connections a resistor of 1kQ each has to be connected n gt a7 i 2 1 25 3 L T2 gt R AN 2 1 2 5 1 35G L T3 a a gt R3 ne rn For the photo cell test the controller MO63 has to learn the quantity of photo cells which are connected by activating the dip switch S9 on and TE 9 R6 learning the running time again L2 1 2 5l T X1 260 X1 26u X1 1u X1 2u X1 90 X1 9u Terminal X1 6 Programming The controller has to learn the following parameters Running time for opening and closing Torque power for reversal on hitting an obstruction Quantity of photo cells when the photo cell test is activated Time to stay open for automatic closure Personal code for radio remote control On delivery 5 seconds open before automatic closure and the running time for the barrier are already saved 6 1 Running time and automatic closure a Push the learn button approx 3 seconds the red Diag LED starts flashing b Push the learn button again When the photo cell test is activated S9 on the controller learns how many photo cells are connected During learning the Diag LED flashes at 1 second intervals then the learning of the running time starts automatically When the photo cell test is not activated S9 off the learning of the running time starts immediately c The Diag LED is lit during the learning of t
8. Barriers MODPARK Parking System ANJEL 4 Operating mode MO63 Switch off the mains supply before altering the operating mode dip switches 1 9 4 1 Pre warning before opening S1 und S2 VWA The warning light flashing or amber light illuminates right after a signal to open if pre warning time before opening is activated The barrier opens after the pre warning time has elapsed S1 off and S2 off No pre warning time S1 off and S2 on 1 5 s pre warning time before opening S1 on and S2 off 4 0 s pre warning time before opening 4 2 Pre warning before closing S3 VWZ The warning light flashing or amber light goes on right after a signal to close if pre warning time before closing is activated The barrier closes after the pre warning time has elapsed S3 off No pre warning time before closing S3 on 4 0 s pre warning time before closing 4 3 Automatic closure S4 ZLA The open barrier closes automatically after the programmed stay open time has elapsed An earlier closing of the barrier is possible by BT or BTZ Is a stop signal given during the stay open time then the automatc closure is blocked and is only released again by a new signal BTA1 BZA2 or LS keep the barrier in the end position open even after the stay open time has elapsed The barrier closes immediately when a signal BTA1 BTA2 or LS is removed S4 off No automatic closure S4 on The barrier closes after the time which was saved during the
9. Manual Barriers GESELLSCHAFT F R AUTOMATISIERUNG UND SYSTEMTECHNIK MODPARK Parking System ANJEL as Installation and operating instructions Barriers AB 25 AB 25HS AB 30 AB 40 AB 50 AB 60 AB 80 Contents page 1 Technical data AB 25 AB 40 2 1 1 Dimensions AB 25 AB 40 2 1 2 Installation AB 25 AB 40 3 2 Technical data AB 50 AB 80 4 2 1 Dimensions AB 50 AB 80 4 2 2 Installation AB 50 AB 80 5 3 Controller MO 63 6 3 1 Connections 6 3 2 Further connections 7 3 3 Visual indication 7 4 Operating mode MO 63 8 5 Photo cell test 9 6 Programming 9 6 1 Running time and automatic closure 9 6 2 Setting personal code for radio remote 10 7 External connections 10 8 Layout in the barrier 11 9 Fault finding 13 10 Maintenance 15 11 Radio remote control 16 12 Extra equipment swinging support folding boom 17 13 General notes to safety 21 ze i MODPARK Parking System ASYTEET Manual Barriers F R AUTOMATISIERUNG UND SYSTEMTECHNIK 1 Technical data AB 25 AB 40 Operative range General Data Application Parking area parking garage Mains supply 230V 50Hz for Company entrance Max current 2 5A Safety area Duty cycle 100 Toll station Degree of protection IP 54 Drive pulse Push button card reader key switch Temperature range 20 C to 70 C from remote contro
10. N cs 3 So D f rs D m fh AN oO D N brass bush short bearing brass bush long za support connecting rod horizontal boom IT gt side plates lt lt B r Ib a We reserve the right to make technical improvements without prior notice T Dokumentation Modpark Peripherie Schranken Englisch AB25 80 M063 En2002V 11 DOC Page 18 of 22 Manual Barriers IR AUT TOMATISIERUNG UND SYSTEMTECHNIK MODPARK Parking System ANJEL Fs 12 2 Swinging support for AB 40 AB 80 a Close the barrier b Using the screws B connect the upper and lower parts in the approximate length c Remove about 500 mm of the rubber tubing under the boom and push the securing piece A into the slot Secure it with the two hex socket screws d Push the rubber tube into the slot and cut off the protruding part e A fine adjustment of the length can now be made on the foot D f Screw a4 mm screw into the hole E g The foot can now be screwed to the appropriate position a We reserve the right to make technical improvements without prior notice T Dokumentation Modpark Peripherie Schranken Englisch AB25 80 M063 En2002V 11 DOC Page 19 of 22 M
11. Ol ge a Test ight barier o o JO Ae ma Arming loop activated MI 65 No 3 4 a a el Bl aF a ANAAO Closing loop e o O Rea pooo Arming loop a 2 We reserve the right to make technical improvements without prior notice T Dokumentation Modpark Peripherie Schranken Englisch AB25 80 MO63 En2002V 11 DOC Page 12 of 22 Manual Barriers OR AUTOMATISIERUNG UND SYSTEMTECHNIK MODPARK Parking System AY Ci 9 Fault finding 9 1 The closed barrier doesn t react to a signal to open Symptom Possible solution The yellow power LED is out No mains supply Check the mains lead and the fuses The red diagnostic LED flashes Programming is started Carry it out to the end non stop The green LED BTS1 is lit The controller is switched off a Operating mode switch 1 off b Switch On Off switch X1 4 top and X1 4 bottom off The green LED BTS2 is out a The stop button is pressed Release the button X1 8 top and bottom b Emergency release in use Lock the shaft The green LED SEA is out and the a Faulty limit switch open Replace the limit switch red Diag LED flashes 4 times then a break and plug V6 on the controller The green LED BTZ1 is lit Check the button X1 2 bottom top close and 7 top When the controller gives an error code through the red Diag LED see the chapter 9 4 9 2 The open barrier doesn t react to signals to close Symptom Possible solution The yellow pow
12. anual Barriers IR AUT TOMATISIERUNG UND SYSTEMTECHNIK MODPARK Parking System ANJEL Fs 12 3 Fixed support with electromagnet Connect the flexible lead from the magnet to the cable from the barrier There is enough room in the lower part of the support for a junction box a ma Fit the forked part onto the foot and secure it in the required height e c Remove the rubber tube from the boom at the point at which the anchor plate is to be secured Push one of the securing pieces followed by the anchor plate into the slot of the boom until the plate is immediately above the magnet Push the second securing piece up to the magnet oO gt f Push the securing pieces from both sides against a the anchor plate and secure them with the screws Connecting the magnet in the barrier a The 4 seconds warning before opening must be activated Switch 2 on the logic board b The coil of the relay must be connected to the terminals 14 top and 14 bottom in the terminal block c Connect contact 11 of the relay to 1 bottom in the terminal block d Connect contact 21 of the relay to 2 top in the terminal block e The leads to the magnet come from the contacts 12 and 22 of the relay OPERATION 1 The relay switches off on receipt of a signal to open The magnet loses it s residual magnetism during the 4 seconds warning time 2 The barrier opens after the 4 seconds
13. contact will be closed when the red light is lit Maximal admissible 24V 1A V15 14 X1 11u Common terminal for display barrier open and barrier closed Motor V2 1 X1 20 Motor open Motor V2 2 X1 22 Motor close Red traffic V2 3 X1 130 The red traffic light is on when the barrier is closed The red traffic light light is also on during the time warning prior to opening max 230V 120W Amber or V2 4 X1 140 The contact for the Amber or the flashing light is closed when the flashing light barrier is moving and during the time warning prior movement max 230V 120W Green traffic V2 5 X1 150 The green traffic light is on when the barrier is open During the time light warning before closing the green traffic light is out max 230V 120W L1 V2 6 X1 17u L1 power supply 230V 50Hz further connections X1 160 16u 170 17u N V2 7 x1 19u N power supply 230V 50Hz further connections X1 13u 14u 15u 180 18u 190 19u 3 3 Visual indication LED _ Colour Funktion m remote control receives a signal BTA BTZ1 LED is lit when contact BTZ1A or BTZ1B is closed BTZ2 LED is lit when contact BTZ2 is closed Dig red Error code and display for radio remote control We reserve the right to make technical improvements without prior notice T Dokumentation Modpark Peripherie Schranken Englisch AB25 80 M063 En2002V 11 DOC Page 7 of 22 En IR AUT TOMATISIERUNG UND SYSTEMTECHNIK Manual
14. e boom down the release bolt will then lock at the appropriate position The controller is switched off until the boom is locked at the operating position g Mount the boom before doing a test run If necessary adjust the limit switches and the stoppers The logic board MO 63 is connected to the terminals X1 in the barrier and to the microswitches in the head All electrical connections should be carried out at the front of the terminals X1 The barrier is ready for use when delivered The running time and a stay open time of 5 seconds are stored in an EEPROM You only need the programming mode if the time to stay open when automatic closure is being used is to be altered the photo cell test is activated or when a controller is replaced Switch off the mains supply before altering the operating mode dip switches We reserve the right to make technical improvements without prior notice T Dokumentation Modpark Peripherie Schranken Englisch AB25 80 M063 En2002V 11 DOC Page 3 of 22 r mgne MODPARK Parking System ASYTEET Manual Barriers F R AUTOMATISIERUNG UND SYSTEMTECHNIK 2 Technical data AB 50 AB 80 Operative range General data Application Parking area Mains supply 230V 50Hz for Parking garage Max current 2 5A max Company entrance Duty cycle 100 Safety area Degree of protection IP 54 Drive pulse Push button ca
15. e gun grease the bearings of the main shaft grease must be suitable for 25 C to 125 C Check that the boom reaches the horizontal and vertical positions If necessary re adjust the limit switches and the mechanical stoppers Ensure that the potential earthing cable is still connected to the housing and to the door Check that all safety equipment works correctly Loops photo cells and the reversal on obstruction Oil the emergency release bolt and check the function Check that the pre determined breaking point has the correct nuts and bolts use ASYTEC vandalism set only Check that the operating instructions are complete We reserve the right to make technical improvements without prior notice T Dokumentation Modpark Peripherie Schranken Englisch AB25 80 M063 En2002V 11 DOC Page 15 of 22 MODPARK Parking System ASTE mo W MeH GESELLSCHAFT Manual Barriers F R AUTOMATISIERUNG UND SYSTEMTECHNIK 11 Radio remote control Example A Receiver using the code switches on the logic board MO 33 MO 43 or MO 542 or receiver with code switches in conjunction with the boards MO 32 MO 35 MO 42 MO 52Z2 MO 60 or MO 62 Follow the example in the diagram below Receiver Transmitter channel 1 4123456789 4123456789 5 oy OPTRA WW eH lt __ ONPLWAL Ud ae channel 2 4123456789 4123456789 o RR HL c
16. ed and closed Additional functions of BT depend on setting of the dip switches for automatic closure S4 and the counter settings S6 When the automatic closure is activated or the counter is deactivated then the barrier can be closed by BT otherwise the barrier will be opened When the automatic closure is blocked e g by a stop signal and the counter is activated then BT can only open the barrier Which means that closing by BT is not possible Push button open 1 and 2 n o V15 2 X1 60 and V15 3 X1 6u When one of the contacts BTA1 or BTA2 is open and the other is closing the barrier opens When the barrier is open and BTA1 or BTA2 is being closed then the barrier cannot be closed constant open Push button close 1A and 1B n o V15 4 X1 70 and V15 9 X1 10u When BTZ1A closes while BTZ1B is open or BTZ1B closes while BTZ1A is open the barrier closes When the barrier is closed and at least one contact is closed the barrier cannot be opened constant closed Push button close 2 n o V15 5 X1 7u When the contact BTZ2 is opening the order close is given Push button stop 1 n o V15 6 X1 40 When the contact BTS1 is closed the barrier stops Stored signals are erased Automatic closure is blocked until the next signal We reserve the right to make technical improvements without prior notice Page 6 of 22 MODPARK Parking System CD H la Manual Barriers
17. er the green LED SEA and the green LED BTS2 If is not the case then see chapter 9 Fault finding Warning Please check the direction of rotation of the transmission lever of the gearbox The reversal by obstruction can only work when the rod always moves to the rear of the housing never to the door We reserve the right to make technical improvements without prior notice T Dokumentation Modpark Peripherie Schranken Englisch AB25 80 MO63 En2002V 11 DOC Page 10 of 22 MODPARK Parking System AT Tel Manual Barriers GESELLSCHAFT F R AUTOMATISIERUNG UND SYSTEMTECHNIK 8 Layout in the barrier z g i i F 5588 i we g 83 X page g B HE BSS 6 bifiphe fee gy H dfcsffk frp 28 gg Saagade Bee RE 88 We reserve the right to make technical improvements without prior notice T Dokumentation Modpark Peripherie Schranken Englisch AB25 80 MO63 En2002V 11 DOC Page 11 of 22 J Lie MODPARK Parking System AGYI A ae GESELLSCHAFT Manual Barriers FUR AUTOMATISIERUNG UND SYSTEMTECHNIK External Connections x lt lt H Barrier open green traffic light L1 X Barrier moving amber traffic light or flashing light LI J Barrier closed red traffic light Feedback vehicle passed MI 65 No 5 6 Close barrier command MI 65 No 48 49 Open barrier command MI 65 No 51 52 1 Button Operation F Pa ON OFF Boom broken contact MI 65 No 1 2 o o
18. er LED is out No mains supply Check the mains lead and the fuses The red diagnostic LED flashes Programming is started Carry it out to the end non stop The green LED LS is lit a Loop detector is activated Check the detector in socket B3 b The red jumper is removed from Plug the detector into the socket the terminals 6 and 10 in socket B3 or replace the red jumper B3 but the loop detector hasn t been inserted c The photo cell is activated Check it X1 9 top and X1 9 bottom The green LED LS is lit when the The photo cell is connected as Connect the photo cell as normally photo cell is free and not lit when normally open closed an obstacle is present open bottom and X1 6 top socket B2 the control box terminals BTZ2 X1 2 bottom top The green LED SEZ is out and the a Faulty limit switch closed Replace the limit switch red diagnostic LED flashes 4 times then a break We reserve the right to make technical improvements without prior notice T Dokumentation Modpark Peripherie Schranken Englisch AB25 80 M063 En2002V 11 DOC Page 13 of 22 B JAFT MODPARK Parking System ANTE ae Manual Barriers GESELLSCH R AUTOMATISIERUNG UND SYSTEMTECHNIK 9 3 Fault finding continued Delay before closing Switches off tries to carry on closing Adjust it The boom isn t vertical when the barrier is open The green LED SEA is out Limit switch open maladjusted Re adj
19. er in advance If the appliance is used other than in the recommended manner the user must ascertain that no danger for himself or others will result from this use He should also ascertain that the planned use will have no detrimental effect on the appliance itself The appliance should only be used when all safety equipment is available and in working order All faults which could be a source of danger to the user or to third persons must be eliminated immediately All warning and safety notices on the appliances must be kept legible All electrical periphery equipment which is connected to the appliance must have a CE Mark which ensures that it conforms to the relevant EEC regulations Neither mechanical nor electrical alterations to the appliance without explicit agreement of the manufacturer are allowed All alterations or extensions to the appliance must be carried out with parts which ASYTEC GmbH have defined as suitable for such alterations and be carried out by qualified personnel Any contravention of these conditions revokes the manufacturer s guarantee and also the CE Mark and the user is alone responsible for the consequences Our service department is available to answer all queries about these conditions and of course about our appliances The operation of the system within CEN countries must also be conformant with the European safety relevant directives and standards We reserve the right to make technical improvements wit
20. erie Schranken Englisch AB25 80 M063 En2002V 11 DOC Page 5 of 22 MODPARK Parking System Manual Barriers a Tel IR AUT TOMATISIERUNG UND SYSTEMTECHNIK 3 Controller MO 63 3 1 BT BTA1 BTA2 BTZ1A BTZ2 BTS1 T Dokumentation Modpark Peripherie Schranken Englisch AB25 80 M063 En2002V 11 DOC LERN BIBT O K K Diag Vp cvs BT x RBTA BTA1 BTA2 BTZ1A Ir n beg a RBTZ2 fel F z T i BTZ2 He ars I B 1 Receiver radio E He BTS T remote control eH i u alia HBTS mel BTS2 o z t ts lo RBTS2 Del BTZ1B o be SER Q H Noboom Go dese SRE Was ca WSEZ 8 of is IT a en yz Barrier open Ce hes wil geai Barrier closed o im T 3 Je EN Q jew LSTST ls sa RES SEA p olj 2 SEZ E sin eo lw I o Transformer No boom u MO63 Lo N Stop gt K ar ole Photo cell test 24V 0 1 24Vde max 500mA 12Vde max 500mA ZIA be zt I N Eu m a B 38 a S o a 2 3 4 3 6 7 v2 l o g a Ne Q Mm U Motor Red light Green light Barrier closed Bene open ai N tasting ighi aan 50Hz Connections Single push button n o V15 1 X1 50 With the serial switching BT the barrier can be open
21. hannel 3 a 4123456789 4123456789 3 gt oe A l channel 4 BEI LIT e ia Bu Transmitter SK SKX and SKI in conjunction with K Type receivers using code switches The switches 1 to 7 in transmitter and receiver must have the same settings The switches 8 and 9 of the receiver allocate a channel appropriate to the button of the transmitter The switches 8 and 9 in multi channel must be set at 0 The examples on the right in the diagram above show the allocation of a channel with a one channel transmitter using the switches 8 and 9 as in the receiver Example B Receivers without code switches Logic boards MO 34 MO 44 MO 55 These receivers learn the code from the transmitter as described in the paragraph Learning personal code in these installation instructions Example C Combination of examples A and B A garage door opener with MO 55 and a swing gate opener with either MO 32 MO 33 1 Set the code of the transmitter and receiver for the swing gate opener as described above Switches 1 to 7 have the same settings in both transmitter and receiver The switches 8 and 9 set at 0 4123456789 On AURA HAH The swing gate opener now receives signals from the first button of the transmitter 2 You can now allocate the second button to the garage door opener by going through the procedure described in the installation instructions for the garage door opener in the paragraph Learning persona
22. he running time The barrier closes if it is not closed already If it is closed then it opens and learns the running time for opening Then the Diag LED flashes at 1 second intervals and the controller learns the stay open time d After the required stay open time push the learn button again The barrier closes automatically and learns the running time for closing and the torque power for the reversing on obstruction The learnt values are stored even if power failure occurs and the Diag LED turns off We reserve the right to make technical improvements without prior notice T Dokumentation Modpark Peripherie Schranken Englisch AB25 80 M063 En2002V 11 DOC Page 9 of 22 MODPARK Parking System ASYTTE me l B i W MeH M GESELLSCHAFT anua arriers FUR AUTOMATISIERUNG UND SYSTEMTECHNIK 6 2 Setting personal code for radio remote Push the learn button approx 3 seconds the red Diag LED starts flashing Push the corresponding button on your transmitter The contoller learns the code the red Diag LED is lit while a signal is received Release the button The code is stored even if power failure occurs and the Diag LED turns off Cancel personal code Push the learn button approx 3 seconds the red Diag LED starts flashing Keep the learn button pushed for approx 10 seconds The red Diag LED lights for 2 seconds the personal code is erased and the learning is finished 7 External connections For the power supply
23. hout prior notice T Dokumentation Modpark Peripherie Schranken Englisch AB25 80 M063 En2002V 11 DOC Page 21 of 22 En IR AUT TOMATISIERUNG UND SYSTEMTECHNIK MODPARK Parking System ANJEL Manual Barriers ASYTEC GmbH In der Dalheimer Wiese 1 D 55120 Mainz Herstellererkl rung im Sinne der EG Maschinenrichtlinie 98 37 EG Anhang II B Manufacturer s Certificate conforming to the Directive 98 37 EEC Appendix II B Hiermit erkl ren wir da die nachfolgend bezeichneten Schranken aufgrund ihrer Konzipierung und Bauart sowie in der von uns in Verkehr gebrachten Ausf hrung den einschl gigen grundlegenden Sicherheits und Gesundheitsanforderungen der EG Maschinenrichtlinie entspricht We hereby declare that the below mentioned road barriers conform in concept and design as well as types distributed by us with the relevant safety and health recommendation of the EC community machine directive Bei einer nicht mit uns abgestimmten nderung der Schranken verliert diese Erkl rung ihre G ltigkeit In case of an alteration of the road barriers not authorised by us this declaration is unvalid Bezeichnung der Schranken AB25 AB25HS AB30 AB40 AB50 AB60 AB80 Types of road barriers Einschlagige BABtimmungen 98 37 EG 9 GSGV Relevant regulations 73 23 EWG 1 GSGV 89 336 EWG EMVG Angewandte Normen Applied standards DIN EN 12445 Nutzungssicherheit kraftbet tigter Tore Pr fverfahren DIN EN 12453 Nutzungssiche
24. k everything for mechanical damage and replace where necesary Check that the barrier is still secure on the foundation Tighten screws where necessary Check the plastic screws at the boom holder Using a grease gun grease the bearings of the main shaft grease must be suitable for 25 C to 125 C Check that the boom reaches the horizontal and vertical positions If necessary re adjust the limit switches and the mechanical stoppers Ensure that the potential earthing cable is still connected to the housing and to the door Check that all safety equipment works properly Loops photo cells and the reversal on obstruction Oil the emergency release bolt and check the function Check that the pre determined breaking point has the correct nuts and bolts bolts M8x45 ISO 4762 12 9 and nuts M8 ISO 4032 5 2 Check that the operating instructions are complete 10 2 Maintenance AB 50 AB 80 The maintenance intervals must be decided individually as they are dependent on the frequency of use We recommend maintenance at least once every six months The springs are designed for 250 000 openings Check the spring assembly In case of faulty springs all springs must be replaced at once Check the spring tension as explained in 2 2 Check everything for mechanical damage and replace where necesary Check that the barrier is still secure on the foundation Tighten screws where necessary Using a greas
25. l code We reserve the right to make technical improvements without prior notice T Dokumentation Modpark Peripherie Schranken Englisch AB25 80 M063 En2002V 11 DOC Page 16 of 22 En Manual Barriers R AUTOMANSIERUNG UND SYSTEMTECHNIK MODPARK Parking System ANJEL 12 Extra equipment 12 1 Folding boom for AB 25 AB 40 All numbers refer to the following drawing Determine the length of the vertical part of the boom 1 The length L3 should not be longer than the distance from the deck to the ceiling L1 minus 945 mm The maximum vehicle height L2 is the ceiling height L1 minus 160 mm L3 max 1500 mm a Screw the support 6 with the internal reinforcing plate 7 onto the barrier casing b Cut the boom into two pieces with the appropriate length c Cut off 60 mm from the rubber tube from the vertical part of the boom d For the connection of the side plates to the horizontal boom drill 2 x 2 holes 6 5 mm in the cut end of the boom find the drawing on page 11 Using the four M 6 x 45 bolts secure the side plates 3 on the boom Place a washer M6 between side plate and boom to maintain clearance e Screw the pivot bolt 13 onto the support 6 f Push the short brass bush 14 and the bearing 8 onto the pivot bolt M8x50 and secure them g Push the bearing 9 into the cut off end of the vertical part of the boom Drill 2 holes 5 0 mm from the bottom side in the boom 15 and 40 mm from the cut end
26. l desk top panel etc Controller MO 63 Handsfree data capture Measurement w l h 350x300x1100 mm Induction loop Foundation frost proof 550x500x800 mm Safety Reversing on obstacle Boom connector left or right Best protection against vandalism Housing aluminium Ergonomic emergency release Mechanical parts steel zinc coated AB2 s JAB 25HS ABS ABO 5 Typical Data Drawn power Running time Maximum boom length Effective length Reversing on obstacle Boom weight O O Barrier weight A The accident prevention regulations and the approved safety rules have to be observed Moving parts inside the barrier can cause accidents Do not operate the barrier when housing is open 1 1 Measurements AB 25 AB 40 T o Q oO et qa oO N co 300 350 Boom length minus 360mm Drilling template 160 banier housing N rot a t 500 oO S 3 R n 9 a 2 N amp 130 e EE E u eee Fixed support 8 Cy al le er Foundation 500x550x800 al 2500 3000 4000 We reserve the right to make technical improvements without prior notice T Dokumentation Modpark Peripherie Schranken Englisch AB25 80 M063 En2002V 11 DOC Page 2 of 22 Manual Barriers IR AUT TOMATISIERUNG UND SYSTEMTECHNIK
27. of the external equipment e g photo cells induction loops the controller provides stabilised 24 Vdc and 12 Vdc Max 500 mA can be drawn from the 12 V source and the 24 V source but together max 700 mA The supply of the photo cell transmitter during photo cell test comes from the 24 V source and has to be considered 1 tae ay IT i E za sg 9 2 peg iirc F pm P a Fi a sae 28 fume 5 4 4 z E zE 2 g g 4 E Fi LH Barrier open green traffic light gt _ i ru i pm SE 5 Bo F 1H Bamer mowing amber traffic light or ashing light ao 1 i g Fi E Z gt 4 Rop tl H Barrier closed red traffic light is He g zz au f p E RS 2 5 FE a un a E we ay Wb w Hs A Important instructions when using loops for safety and closing When using a loop detector for safety remove the red junper between contects 6 and 10 on the socket B3 The socket B3 is always for the loop under the barrier boom and is prewired for safety and for closing when leaving the loop When B3 is equipped with a 2 channel detector the second channel may be used for an opening loop or a loop detecting that a vehicle is present The socket B2 is prewired for an opening loop in connection with a 1 channel detector Please see chapter 10 Examples for use of loop detectors When all connections are completed and the barrier is closed only the following LEDs should be lit the yellow LED Vp for main pow
28. panel Secure the boom assembly on both ends of the shaft The barrier is delivered in the open position which means the n assembly must be vertical Secure the boom holder on the assembly The two parts are Y then joined together Counter nut e Remove the adjusting nut from the spring assembly If the boom is to be shortened 2009 reduce the number of springs The following table shows approximate values check that fo we the balance is as described under f The springs must be divided equally between the Moti back and the front One spring alone may not be used The springs should be inspected nut regularly and be tightened or replaced if necessary Length of boom mm AB 50 3000 3500 4000 4500 5000 Springs without folding skirt Spring with folding skirt Length of boom mm AB60 80 5000 5500 6000 6500 7000 7500 8000 Springs without folding skirt A 4 i S 6 8 8 __ Spring with folding skirt 5 6 7 8 10 12 14 16 18 The following values are only for the round boom Length of boom mm AB50 60 80 3000 4500 5000 5500 6000 7000 8000 Spring without folding skirt pea eo soe aa Se ee TES Spring with folding skirt p 2 3 ft 4 5 7 89 f When all electrical connections are completed ensure that the spring assembly is not yet connected to the drive shaft Close the barrier with the motor and then mount the boom Pull the emergency release lever and push the boom into the ve
29. rd reader key switch Temperature range 20 C to 70 C from remote control desk top panel etc Controller MO 63 Handsfree data capture Measurements w l h 400x450x1100 mm Induction loop Foundation frost proofed 600x650x800 mm Safety Reversing on obstacle Boom connector central Best protecting against vandalism Housing aluminium Ergonomic emergency release Mechanical parts steel zinc coated Typical Data AB 50 AB 60 AB 80 Running time ca 4 0s ca 5 5s ca 8 5s Maximum boom length Effective length Fixed swinging support The accident prevention regulations and the approved safety rules have to be observed Moving parts inside the barrier can cause accidents Do not operate the barrier when housing is open Reversing on obstacle Boom weight O O Barrier weight A 2 1 Measurements AB 50 AB 80 N D ef je a a a 7 i q e Mi 145 q Length of boom m Ss co Drilling template banier housing 165 165 160 450 400 T fo 3 t 7 mg Q o g j Al 3 LPH OS 1 y S Bot m a S 130 at Re i Bo ot Fixed support N 165 165 fo noi f bo 2 eel esse w w a 5000 6000 8000 Foundation 600x650x800 650 We reserve the right to make technical improvements without prior notice T Dokumenta
30. rheit kraftbet tigter Tore Anforderungen DIN EN 292 1 2 Sicherheit von Maschinen DIN EN 60204 1 Elektrische Ausr stung von Maschinen DIN EN 50081 2 Elektromagnetische Vertr glichkeit DIN EN 50082 2 Elektromagnetische Vertr glichkeit Hinweis Die Inbetriebnahme der Toranlage in die diese Schranke eingebaut werden soll ist so lange untersagt bis festgestellt wurde dass die Toranlage den Bestimmungen der Richtlinie 98 37 EG entspricht The usage of the complete gate in which this barrier is used is forbidden until it is proven that the complete gate fulfils the directive 98 37 EEC Mainz Jan 30 2002 ASYTEC GmbH Eugen Weiss General Manager We reserve the right to make technical improvements without prior notice T Dokumentation Modpark Peripherie Schranken Englisch AB25 80 M063 En2002V 11 DOC Page 22 of 22
31. rrier closes 4 8 Photo cell test S9 LSTST Before each closing of the barrier the photo cells may be tested S9 off Photo cell test is not activated S9 on A photo cell test occurs before each closing Attention The photo cell test has to be learnt when programmimg the controller We reserve the right to make technical improvements without prior notice T Dokumentation Modpark Peripherie Schranken Englisch AB25 80 M063 En2002V 11 DOC Page 8 of 22 En IR AUT TOMATISIERUNG UND SYSTEMTECHNIK Manual Barriers MODPARK Parking System ANJEL 5 Photo cell test Before the closing of the barrier the photo cells may be tested The photo cell test consists of two parts Part one The transmitter is taken off the power supply and then the receiver has to report an obstacle within max 2 5 seconds Part two The transmitter is connected to the power supply again and then the receiver has to report that no obstacle is present If during part one the receiver does not report an obstacle the photo cell is faulty and an error code is shown on the Diag LED flashes 6 times If during part two the obstacle is still being reported the controller assumes a real obstacle being present the barrier will not close No error code is shown Max 6 photo cells can be connected to the controller MO63 and be tested For the testing of more than one photo cell the relay connections of the receivers have to be connected in series Parallel to
32. rtical position Screw the adjusting nut onto the connecting rod and tighten the springs Pull the release lever again and push the boom down if the spring tension is correct it should move easily to about 45 After that the boom has to be pushed down g The connecting rod of the AB 50 to AB 80 consists of two parts which are screwed Be together and form a predetermined breaking point in case of vertical force on the ae ER boom The boom is then disconnected from the shaft and is pulled to about 45 by a Pre determined the springs If a break occurs here the nut and the bolts must be replaced with the gt N original ASYTEC vandalism set The nuts must be secured with thread lock The nuts may only be replaceed with those supplied by ASYTEC l The logic board MO 63 is connected to the terminals X1 in the barrier and to the microswitches in the head All electrical connections should be carried out at the front of the terminals X1 The barrier is ready for use when delivered The running time and a stay open time of 5 seconds are stored in an EEPROM You only require the programming mode if the time to stay open when automatic closure is being used is to be altered the photo cell test is activated or when a controller is replaced Switch off the mains supply before altering the operating mode dip switches We reserve the right to make technical improvements without prior notice T Dokumentation Modpark Periph
33. tion Modpark Peripherie Schranken Englisch AB25 80 M063 En2002V 11 DOC Page 4 of 22 En IR AUT TOMATISIERUNG UND SYSTEMTECHNIK Manual Barriers MODPARK Parking System ANJEL 2 2 Installation AB 50 AB 80 a When you prepare the concrete foundation lay enough cable or a plastic duct for the cable you need The foundation must be at least 800 mm deep with a horizontal surface 500 x 550 mm Release bolt b Emergency release during current failure etc Pull the lever with the red end which is behind the access panel The boom can then be raised manually To engage the boom again pull the lever and pull the boom down the release bolt will then lock at the appropriate position The controller is switched off until the boom is locked at the Il operating position c Using the template you can either incorporate bolts in the foundation or drill holes in the hardened concrete for heavy duty fixings The door side of the template must face Release lever Spring assembly towards the road on which the barrier will be closing Secure the barrier on its foundation ns Ensure that the housing is vertical The screws or bolts at the thickly marked points 4 drawing on page 4 also secure the foot of the spring assembly Banel Q d The left and right parts of the boom assembly aren t identical The greater distance between the edge and the hub must be towards the access
34. ust it and the corrsponding but still switches mechanical stopper The green LED SEA is lit The red a Faulty limit switch open Replace it diagnostic LED flashes twice then a break ee een e maladjusted and doesn t switch mechanical stopper The boom isn t horizontal when the barrier is closed The green LED SEZ is out Limit switch closed maladjusted Re adjust it and the corrsponding but still switches mechanical stopper The green LED SEZ is lit The red a Faulty limit switch closed Replace the limit switch diagnostic LED flashes three times then a break EE Sei maladjusted and doesn t switch corresponding mechanical stopper 9 4 Error code The red Diag LED serves as a status indicator During regular fault free operation the LED is only lit when a radio remote signal is received An error code is given when the controller detects a fault the Diag LED flashes max 12 times then a break then repeats the flashing code Cause solution 2x flashing Limit switch OPEN did not open after the learnt running time The limit switch has a short circuit 3 x flashing Limit switch CLOSE did not open after the learnt running time The limit switch has a short circuit controller is blocked power source load is too high The controller is blocked Check the connected equipment 6 x flashing Photo cell error The following error occurred during the photo cell