Operating Instructions BA Touch II
Contents
1. No Controller Address _ Zone 1 ET 132714806A 32 2 ETR132704206D eS By the button Start Scan the BA Touch II scans the CANBus for controllers The CANBus is scanned from node id 32 up to node id 127 The identified controllers are entered in a list the zones are consecutively numbered Right to technical changes reserved Rev 1 00 02 PSG Plastic Service GmbH 27 Operating Instructions BA Touch Il 8 4 Recipe Administration Tf Recipe Administration 6099 GESAMT SK 6242 TESTI In the recipe administration parameter sets of the controller are stored on the Compact Flash Card and are loaded again into the controller from Compact Flash Card 8 5 Hot Runner Mold Identification Y Hot Runner Mold Identification According to the jumpers set for the plug at the hot runner mold BA Touch II sends a coding between 1 and 255 For each coding a recipe can be assigned where the settings are taken from after activation of the Hot Runner Mold Identification By selection of the text field with the recipe name a dialog opens where the available recipes can be selected Right to technical changes reserved Rev 1 00 02 28 Chapter 8 Utility 8 6 System Parameters Tf System Parameter Controller 1 Protocol PSG II Definition Byte 1 Alarm Port 1 Baud Rate 19200 Definition Byte 2 Alarm Port 1 Number of Stop Bits Definition Byte 3 Alarm Port 1 Parity Off Definition Byte
2. operating instructions Right to technical changes reserved Rev 1 00 02 3 4 Chapter 2 Start up 2 Start up At delivery status the PSG ADMIN password is root the USER password is user each without quotation marks For start up perform the following steps Setup and function check of CANBus interface see chapter 8 2 1 CAN Setup f necessary setup of the network configuration see chapter 8 2 2 Network configuration Only required in case of data recording on external network compatible hard disk Setup of USER password and ADMIN password see refer to chapter 8 8 User Administration SCAN CANBus integrate connected controllers in BA Touch Il see chapter 8 3 Scan After execution of the steps mentioned above the system is ready In the menu administration see chapter 8 9 Menu Administration the visible menus for standard user USER as well as user ADMIN can be defined The menu points can be enabled and their position can be rearranged Right to technical changes reserved Rev 1 00 02 3 Operation Menus Note PSG Plastic Service GmbH Operating Instructions BA Touch Il The BA Touch II can be configured by the menu administration see chapter 8 9 Menu Administration The buttons as well as the single menu settings are explicitly enabled for a user and are therefore visible the operating interface On the following pages the buttons and menu settings are described The BA Touch Il is c
3. 0 C 400 0 C rt Cac By S p The button Setpoint value opens a menu where the zones can be selected see chapter 4 1 Zone Selection By a click into the value field a keypad opens where a setpoint value can be entered for the before selected zone 11 Standby x Button Standby DEMO Overview 2 Standby Switch ON Switch OFF Standby Switch ON Standby Switch OFF HAATTE ESE E IL By the button Standby in the footer the Standby function for all zones can be switched on and or off By means of the standby function the setpoint value is decreased for all zones by the value for the standby function Right to technical changes reserved Rev 1 00 02 PSG Plastic Service GmbH Operating Instructions BA Touch Il 12 Boost Button Boost DEMO Overview 2 Boost Switch ON Switch OFF _ Boost Switch ON Boost Switch OFF TAATA Y lt gt By the button Boost in the footer the Boost function for all zones can be switched on and or off By means of the boost function the setpoint value is raised for all zones by the value for the boost function 13 Software Update The software of BA Touch Il is consecutively enhanced By the USB interface for an USB stick and or the slot for a Compact Flash Card the software of BA Touch II can be imported and updated The latest software version can be offered on demand Stop the running BA Touch II system first See 8 2 3 Information Copy the
4. 1 Alarm Port 2 CANopen Base Address 29 Definition Byte 2 Alarm Port 2 Auto Operational Mode Op Definition Byte 3 CANopen Alarm Port 2 Profibus DP Slave 30 Definition Byte 1 Alarm Port 3 FF PAR PAR System parameters are valid for one controller unit By the buttons is selected whether the value is written in block mode for all controller units or in single mode for a single controller In block mode the controllers can be selected by button gt to be written in block mode The green displayed controllers are written the gray displayed controllers not The controllers are selected deselected by click on them By button gt all controllers are selected by button gt all controllers are deselected By selection of a parameter field an input mask is opened WF By button FRE PRR is scrolled to further system parameters Right to technical changes reserved Rev 1 00 02 PSG Plastic Service GmbH Operating Instructions BA Touch Il 8 7 Zone Parameter Tf Zone Parameter Zone Set Point 100 Limit Value 1 Degree Of Operation b Limit Value 2 iii Mode Pn Limit Value 3 zone on Limit Value 4 Alloc Zone 3 Phase 1 Limit Definition 1 Current Transformer Tolerance of Heater 71 0 ie Definition 2 Current Set Point of Heater 2nd Set Point 2nd Current 11a Value 2 i By the button EI EI i In block mode the controllers
5. MCU PCU For software version HRSTouch V1 0 9 1 00 00 01 22 2008 For software version HRSTouch V1 0 6 First edition Right to technical changes reserved Rev 1 00 02
6. box always the last zones selected e g 1 3 are shown here is displayed in the lower display border 120 0 Zone 9 Zone 10 Zone 11 Zone 12 Zone 14 Zone 15 Zone 16 Zone 41 Zone 43 Zone 44 Zone 46 Zone 47 Zone 48 Zone 49 Zone 51 Zone 52 Zone 54 Zone 55 Zone 56 ox Esc Eas ES 4 AL Y 4 1 Zone Selection By the buttons in the footer the zones the change should be valid for are selected Button All Zones all zones are selected and are therefore represented in green Button Block Selection guided by dialog the first and the last zone are selected The first the last and the zones in between build a block that is selected and displayed in green FREE Button No Zones no zones are selected and are therefore represented in gray EE Each zone can be selected green deselected gray by click on it Right to technical changes reserved Rev 1 00 02 10 Chapter 4 Data Input e g Set Point By button Block Selection zone 9 and 14 are selected The block built of zone 9 up to 14 is Example displayed in green For these zones the setpoint value is entered by selection of the setpoint value above the zones and a keypad is displayed where the new value can be entered With the setting 3 BEM the value is directly taken over With the setting rel the present value is changed by the value entered increased decreased For parameters of other values on off list of value etc the inpu
7. can be selected by button EEEE to be written in block mode The green displayed zones are written the gray displayed zones not The zones are selected deselected by click on them By button HH all zones are selected by button HE all Zones are deselected By selection of a parameter field an input mask is opened WF By button FRE 7 FAR is scrolled to further zone parameters By buttons lt gt is scrolled to further selected zones Right to technical changes reserved Rev 1 00 02 is selected whether the value is written in block mode or in single mode 29 30 Chapter 8 Utility 8 8 User Administration 5 Log Book ALO80122 CSV Type Time Entry TY User Administration The passwords for user USER and ADMIN can be changed here In case of change of the password the old password the new password and an affirmation of the new password has to be entered 8 9 Menu Administration TY Menu Administration Default User Admin EF Si Function Activate Deactivate Zone a aia Function Start up Mode with Boost Oo P e i Function Manual Mode Function Automatic Ramp Function Temperature Limits Function Leading Zone z Function Acknowledge Alarms In the menu administration the menu items for each user can be enabled By the pull down menu select the actual menu Edit View Alarm Utility On Off Setpoint Value Standby Boost The menu item for the particular user
8. is activated by setting of a check To change the order of the menu items select one parameter selection in blue color and change the order by pressing the button up or down Right to technical changes reserved Rev 1 00 02 PSG Plastic Service GmbH 31 Operating Instructions BA Touch Il 9 On Off on off button On Off By the ON OFF key the control outlets of all zones are activated and deactivated The buttons are alternately visible In the header the actual status is shown on the left side of the time Overview Right to technical changes reserved Rev 1 00 02 32 Chapter 10 Setpoint value 10 Setpoint value SP t Button Setpoint Value Set Point foaled rer Per od 120 0 C 120 0 C 120 0 C 120 0 C 120 0 C 120 0 C 120 0 C 120 0 C aie 120 0 C 120 0 C 120 0 C pis ais gas cies net le 400 0 C 400 0 C 400 0 C 400 0 C 400 0 C 400 0 C 400 0 C 400 0 C Ea edi Eto 400 0 C 400 0 C 400 0 C 400 0 C 400 0 C 400 0 C 400 0 C 400 0 C peehi 400 0 C 400 0 C 400 0 C 400 0 C 400 0 C 400 0 C 400 0 C 400 0 C ee ee ee ee 400 0 C 400 0 C 400 0 C 400 0 C 400 0 C 400 0 C 400 0 C 400 0 C EI Sree Ed bol 400 0 C 400 0 C 400 0 C 400 0 C 400 0 C 400 0 C 400 0 C 400 0 C PEEHI EEEE 400 0 C 400 0 C 400 0 C 400 0 C 400 0 C 400 0 C 400
9. value degree of operation and current are displayed By a red error and or green O K led the alarm condition of the zone is displayed by a text field the status of the zone A bar represents the actual control deviation By the buttons and the set point can directly be changed By selection of a value of a zone you can change to Direct Entry for Zone see chapter 5 For passive zones the value is displayed in gray color 6 8 4 Zone View a mj Button 4 zones or button View and menu selection 4 zones DEMO 4 Zones Increase Set Point Decrease Set Point EPI A Ty Gal 141 4 gt In the view of 4 zones the process values set point actual value degree of operation and current are displayed By a red error and or green O K led the alarm condition of the zone is displayed by a text field the status of the zone A bar represents the actual control deviation By the buttons and the set point can directly be changed Right to technical changes reserved Rev 1 00 02 18 Chapter 6 Views By selection of a value of a zone you can change to Direct Entry for Zone see chapter 5 For passive zones the value is displayed in gray color 6 9 1 Zone View u mj Button 1 zones or button View and menu selection 1 zones 6 9 1 1 Zone Textual View DEMO Zone 1 Trend View Textual View Increase Set Point Decrease Set Point HAATTE Ab I
10. 0 0 0 0 oof oo Current mra Sna Zone 26 Zone 27 Zone 28 Zone 29 HAATTE FEE EL By selection of the value for current the shown window is displayed A current acceptance can be started Right to technical changes reserved Rev 1 00 02 PSG Plastic Service GmbH 13 Operating Instructions BA Touch Il 6 Views Button View and selection out of displayed list 6 1 Overview HA Button Overview or button View and menu selection Overview Overview In the overview all available zones are displayed The status of the single zone is indicated in terms of color and exemplified for zone 1 Zone 1 passive gray Zone 1 control deviation in between tolerance band 5 K green Zone 1 control deviation out of tolerance band 5 K red actual value above limit value Zone 1 control deviation out of tolerance band 5 K blue actual value below limit value Right to technical changes reserved Rev 1 00 02 14 Chapter 6 Views 6 2 Difference View Button Difference View or button View and menu selection Overview Difference View m N M mm N AN N v v o 6 N N N N Ln wo N N N my mn v v v v c fic A 5 6 J N J N In the difference view the deviation of the actual value is represented with reference to the setpoint value N green line E p as Deviation less than 5 K blue from the setpoint value EE lt i zi Deviation 5 K to 5
11. K green from the setpoint value E SEE ee T Deviation greater than 5 K red from the setpoint value Tn Right to technical changes reserved Rev 1 00 02 PSG Plastic Service GmbH 15 Operating Instructions BA Touch Il 6 3 Bar Chart View m mj Button Bar Chart View or button View and menu selection Bar Chart View Bar Chart View c _ N M in wo a la a I5 o m oO N is Li D m oO nm J a a a a E c 5 E o m Oo oO hi J N N N N Lis In the bar chart view the actual value red and the setpoint value green are represented absolutely a oO J 6 4 30 Zone View A Button 30 zones or button View and menu selection 30 zones T DEMO Act Value C EE 13 26 re EG BE 390 9 120 4 120 7 Zone 11 Zone 12 Zone 13 Zone 14 Zone 15 Control Deviation yellow Zone 16 Zone 17 Zone 18 Zone 19 Zone 20 f t 12075292 399 399 9399 Degree of Operation BEEE yotow Zone 21 Zone 22 Zone 23 Zone 24 Zone 25 Yo Zone 26 Zone 27 Zone 28 Zone 29 Zone 30 A EFS A T FE Yab In the view of 30 zones only one process value is displayed set point or actual value or control deviation or degree of operation or current By the sidewise button bar the process value can be selected By selection of a value of a zone you can change to Direct Entry for Zone see chapter 5 For passive zones the value is displayed in grey color EZER green red Current Right to technic
12. OG Plastic Service Group Operating Instructions Operation and Display Unit for sysTemp Temperature Controllers and Hot Runner Control Cabinets BA Touch Il PSG Plastic Service GmbH P O Box 42 01 62 68280 Mannheim Germany Phone 49 621 7162 0 Fax 49 621 7162 162 www psg online de info psg online de ao Table of contents 1 1 1 1 2 3 3 3 4 4 1 5 1 5 2 5 3 6 1 6 2 6 3 6 4 6 5 6 6 6 7 6 8 6 9 7 1 TZ 8 1 8 2 8 3 8 4 8 5 8 6 8 8 8 8 9 Installation General Information CANBus 1 2 1 Connecting Cable between Controller and BA Touch II Addressing of Temperature Controllers Start up Operation Menus Menu Edit Menu View 3 2 1 Menu Set up 3 2 2 Button Set up Menu Alarm Menu Utility Data Input e g Set Point Zone Selection Direct Entry for Zone Direct Entry for Setpoint Value Direct Entry for Degree of Operation Direct Entry for Current Views Overview Difference View Bar Chart View 30 Zone View 15 Zone View 8 Zone View 6 Zone View 4 Zone View 1 Zone View 6 9 1 1 Zone Textual View 6 9 2 1 Zone Trend View Alarm Actual Alarms Log Book Utility Login Setup 8 2 1 8 2 2 8 2 3 8 2 4 8 2 5 Scan Recipe Administration Hot Runner Mold Identification System Parameters Zone Parameter User Administration Menu Administration CAN Setup Network configuration Information Zone Setup Im Export PSG Plastic Service GmbH Operating Instructions BA Touch I
13. al changes reserved Rev 1 00 02 16 Chapter 6 Views 6 5 15 Zone View a mj Button 15 zones or button View and menu selection 15 zones DEMO 15 Zones on 13 29 Zone 1 Zone 2 Zone 5 FAATA F AY 4 In the view of 15 zones the process values set point actual value degree of operation and current are displayed By a red error and green O K led respectively the alarm condition of the zone is displayed By selection of a value of a zone you can change to Direct Entry for Zone see chapter 5 For passive zones the value is displayed in grey color 6 6 8 Zone View j Button 8 zones or button View and menu selection 8 zones DEMO 8 Tomas HAATTE FD In the view of 8 zones the process values set point actual value degree of operation and current are displayed By a red error and or green O K led the alarm condition of the zone is displayed by a text field the status of the zone By selection of a value of a zone you can change to Direct Entry for Zone see chapter 5 For passive zones the value is displayed in grey color Right to technical changes reserved Rev 1 00 02 PSG Plastic Service GmbH 17 Operating Instructions BA Touch Il 6 7 6 Zone View A Button 6 zones or a button View and menu selection 6 zones DEMO 6 Zones 3 3 Increase Zone 1 Set Point Decrease Set Point oi i FALATE 14 qd gt In the view of 6 zones the process values set point actual
14. ce GmbH D 68309 Mannheim Pirnaer Str 14 16 Tel lt 49 gt 621 7162 0 Fax 162 info psg online de www psg online de Simulation of the interface The version VX Y ZYYMMDD of the installed software is displayed Logged in as user ADMIN the system can be stopped by button Right to technical changes reserved Rev 1 00 02 PSG Plastic Service GmbH 25 Operating Instructions BA Touch Il 8 2 4 Zone Setup fai Zones Setup 2 ia coe 2 poez fe 8 poes ppe Fe e eo Zone 4 11 Zone 11 5 Zone 5 oC 12 Zone 12 oC 6 Zone 6 Pc 13 Zone 13 7 Zone li ec 14 Zone 14 By the column zone a name can be assigned to a zone By the column Unit a unit can be assigned to a zone Is the unit deleted C F is automatically entered For a user defined unit the actual value of the zone is displayed in orange color in all views even if the zone is passive or the set point is 0 Right to technical changes reserved Rev 1 00 02 26 Chapter 8 Utility 8 2 5 Im Export Tf Im Export Directorv list left beside line File list riaht J Memory Stick Load the files of a selected directory Store the files of a selected directory Delete the files of a selected directory Creates new directorv on storaae media By the USB connectors of the BA Touch Il a storage media here named Memory Stick can be connected directories with files can be exported and or imported 8 3 Scan
15. enu one of the following views can be selected and displayed The less the number of zones the more information can be displayed for each zone Overview all available zones Difference View Bar Chart View 30 zones Setpoint Value Actual Value Control Deviation Degree of Operation Current 15 zones Degree of Operation Current 8 Zones 6 Zones Setpoint increase decrease Control Deviation 4 Zones 1 zone Trend or Textual Presentation 3 2 2 Button Set up The view visible on the button is displayed after activation The view visible on the button changes to the next possible view that can be displayed So the zone views are passed through one after the other E 4 gt a o 8 8 gt E 3 3 Menu Alarm Fi Button Alarm In the menu Alarm the following views can be selected Alarm Log Book Right to technical changes reserved Rev 1 00 02 8 Chapter 3 Operation Menus 3 4 Menu Utility Tt Button Utility In the menu Utility the following items can be selected Zone Parameters System Parameters Recipe Administration Hot Runner Mold Identification Scan Setup Right to technical changes reserved Rev 1 00 02 PSG Plastic Service GmbH 9 Operating Instructions BA Touch Il 4 Data Input e g Set Point EF Button Edit After selection of Edit Set Point set point is enabled as a menu item see chapter 8 9 Menu Administration a dialogue
16. f Operation Damping Maximum Degree of Operation in Manual Mode Lower Set Point Limit Upper Set Point Limit Startup Operation Start up Time of Start up Mode Start up Time of 2th Set Point 2th Lowering Value Start up Time of 3th Set Point 3th Lowering Value Start up Time of 4th Set Point 4th Lowering Value Temperature Offset Online Control Function Identification Heating Application Automatic Function for Sensor Break Heating Cooling Relay Output Heating Relay Output Cooling Short Circuit Supervision of Sensor FAL Alarm Output Cooling 1 Alarm Output Cooling 2 Control Parameter Cooling Constant Upper Value of Heater Current Lower Temperature Value Upper Temperature Value Temperature Ramp Automatic Temperature Ramp Correction Factor for XP H Correction Factor for TV TN Amplification Factor for Leading Control Leading Zone Allocation Zone 3 Phase Current Transformer Allocation Zone Measurement Input Group Number Group Release Group Mode lt X X XK KK KK XK XxX X In case a MCU PCU is connected the message Configuration does not support desired function is shown because the parameters marked with X are not supported by MCU PCU Right to technical changes reserved Rev 1 00 02 PSG Plastic Service GmbH 7 Operating Instructions BA Touch Il 3 2 Menu View Button View The menu View works dependant on the setup see chapter 8 2 Setup in 2 ways 3 2 1 Menu Set up In the shown m
17. l O ON NNN FP WWW W W DOWNNNNNNNNNNNNNONONNtrPrArttAeAaoeertrtetrtertortert este st aA OOO ANNDODOHAPRPWNINNHYI VDOVDVADAAWAAUAONN DOO AT KRWBWANDN CO Right to technical changes reserved Rev 1 00 02 1 2 Chapter 1 Installation 9 On Off 10 Setpoint value 11 Standby 12 Boost 13 Software Update 14 Appendix 14 1 Version history Right to technical changes reserved Rev 1 00 02 31 32 32 33 33 35 35 PSG Plastic Service GmbH Operating Instructions BA Touch Il 1 Installation 1 1 General Information The BA Touch II with the PSG programmed user interface enables operation and display of PSG temperature controllers of the sys Temp class The BA Touch II controls up to 128 zones 1 2 CANBus The communication between BA Touch II and the temperature controllers is done by CANBus A network between BA Touch II and the controllers can be done directly or indirectly via CANVTM module A terminating resistor has to be provided on the two outer CANBus participants On the controller there is a jumper between PIN 3 and 4 on the CANBus connector on BA Touch II use a 120 resistor between PIN 2 and 7 On CANVTM the terminating resistor is activated by a jumper 1 2 1 Connecting Cable between Controller and BA Touch II Controller BA Touch ll CAN L 7 2 CAN H 9 7 1 3 Addressing of Temperature Controllers The addressing of the controllers has to be consecutively according to the instructions in the corresponding
18. n the 1 zone textual view the process values actual value setpoint value degree of operation and current are displayed By two text fields the alarm status and the status in plain text are displayed A bar represents the actual control deviation By the buttons and the set point can directly be changed By selection of a value of a zone you can change to Direct Entry for Zone see chapter 5 For passive zones the value is displayed in gray color Right to technical changes reserved Rev 1 00 02 PSG Plastic Service GmbH 19 Operating Instructions BA Touch Il 6 9 2 1 Zone Trend View Zone 1 on 12 20 Trend View Textual View HAATTE In the view of 1 zone trend view the trend of the process values actual value setpoint value degree of operation is displayed By the sidewise button bar trend view or textual view can be selected By click on the time or value scales the scaling can be changed by an input mask After change of the scaling the trend in the window is erased and built up new Right to technical changes reserved Rev 1 00 02 20 Chapter 7 Alarm 7 Alarm AN Button Alarm 7 1 Actual Alarms In the view Alarm the actual unacknowledged alarms of the particular zone with time and date are displayed TENRA ATO E zome o azo eS 12 14 22 01 Z zones fol io Py jet f izo O Excess temperature GW Subnormal tempe
19. omfortably operated by a menu bar at the lower display border The following buttons belong to the menu bar Edit Er O 8 Zones 6 Zones Alarm Fi Utility Tt onon onjoff Current Standby x Boost Back q Next a r Down y E verview Difference View Bar Chart View 30 Zones 15 Zones Dependant on the definition of each single button a menu opens after pressing the button for Edit View Alarm and Utility to select a sub menu items Right to technical changes reserved Rev 1 00 02 5 E Chapter 3 Operation Menus 3 1 Menu Edit EF Button Edit In the menu Edit the value of one parameter for one or several zones is changed Function Manual Mode Function Temperature Limit Function Start up Mode Function Leading Zone Function Automatic Ramp Function Activate Deactivate Zone Function Current Acceptance Function Acknowledge Stored Alarms Function Standby Input1 Function Boost Input 2 Function Code Number Setpoint value Degree of operation Manual mode Lower Temperature Limit GW Upper Temperature Limit GW Current Tolerance Current Setpoint Value 2th Set Point 2th Lowering Value 3th Set Point 3th Lowering Value 4th Set Point 4th Lowering Value Heating Proportional Band Heating Derivate Time Heating Integral Time Heating Sampling Time Cooling Proportional Band Cooling Derivate Time Cooling Integral Time Cooling Sampling Time Heating Degree of Operation Damping Cooling Degree o
20. r 8 Utility 8 Utility Tt Button Utility 8 1 Login Enter password for the user USER or ADMIN For the passwords at delivery status see chapter 2 Start up 8 2 Setup gE m TY Setup Language English iz Date Time hs ft porn is yy Alarm Log Book f Flashdisk PSG alarm Data Log Book n Flashdisk PSG logbug Zone Setup Data Interval 60 S Recipes Flashdisk PSG rezgpt Im Export Ba CAN Setup Network confiquration Information about version View button Z v u unit lS ff Direct input degree of operatio VY On Direct input current acceptance Jott Lox ese can EF The basic setting is done by the setup of the device Language The languages supported depend on the language files available on the storage card Alarm Log Book Activation Deactivation of alarm log book Selection of the storage directory for alarm log book files Data Log Book Activation Deactivation of data log book Selection of the storage directory for data log book files Data Interval Setting of the interval of data storage Right to technical changes reserved Rev 1 00 02 Recipes View Unit Direct input degree of operation Direct input current acceptance 8 2 1 CAN Setup CAH TY Setup TY CAN Setup PSG Plastic Service GmbH 23 Operating Instructions BA Touch Il Selection of the storage directory for the recipe files Wi
21. rature GW Temperature alarm AL Sensor break Fb Sensor polarity FP Short circuit Thyristor alarm SAA Current alarm SAE Sexe Dx kte 2 C Right to technical changes reserved Rev 1 00 02 7 2 Log Book Log Book on 12 34 AL080122 CSV Zone Value A 12 33 54 Insufficient Temperature GW Zone 33 raised A 12 33 52 Sensor Break Sb Zone 8 raised A 12 33 52 Sensor Break Sb Zone 7 raised A 12 33 52 Sensor Break Sb Zone 6 raised A 12 33 51 Sensor Break Sb Zone 5 raised A 12 32 45 Excess Temperature GW Zone 35 isoff A 12 32 45 Excess Temperature GW Zone 34 is off A 12 32 45 Excess Temperature GW Zone 33 is off A 12 32 44 Excess Temperature GW Zone 8 is off A 12 32 44 Excess Temperature GW Zone 7 is off A 12 32 44 Excess Temperature GW Zone 6 is off A 12 32 43 Excess Temperature GW Zone 5 is off A 12 32 43 Excess Temperature GW Zone 4 is off A 12 32 43 Excess Temperature GW Zone 2 is off HAATTE F PSG Plastic Service GmbH Operating Instructions BA Touch Il The backup can be displayed in the log book when the alarms are stored in the file named in the setup see chapter 8 2 Setup By the pull down menu on the upper display border a name of an existent log book can be selected The name of the log book has the following format AL lt year gt lt month gt lt day gt CSV The file can be opened by EXCEL for example Right to technical changes reserved Rev 1 00 02 21 22 Chapte
22. software on an USB stick and or Compact Flash Card Plug in the USB stick on the rear side of the panel and or insert the Compact Flash Card in the slot Start an Explorer on the panel and change to the directory named Memory Stick for USB stick and or Storage Card for Compact Flash Card start program Update exe The following dialog box is displayed Update HRSTOUCH OK Autostart HRSTOUCH Snes Autostart VNC Timeout j3 5 Save Registry SOUrce Destination Start Copy HRSTOUCH Select the button Start Copy HRSTOUCH Change to the directory named Memory Stick HRSTOUCH and or Storage Card HRSTOUCH where you can find the main program IPC exe The installation starts and puts the files into the directory Flashdisk PSG internal flash disk of the panel Right to technical changes reserved Rev 1 00 02 33 34 Chapter 13 Software Update The installation of the software is completed as soon as the button Start Copy HRSTOUCH is active again Exit the menu by CANCEL Answer the questions Update HRSTOUCH with YES and Save Regsitry to Flash with YES The BA Touch II system can be restarted Right to technical changes reserved Rev 1 00 02 PSG Plastic Service GmbH 35 Operating Instructions BA Touch Il 14 Appendix 14 1 Version history Version Date Changes 1 00 02 01 18 2010 Menu items for setup amended For software version HRSTouch V1 1 0 1 00 01 02 16 2009 Menu Edit not supported parameters by
23. t mask could look different Right to technical changes reserved Rev 1 00 02 PSG Plastic Service GmbH Operating Instructions BA Touch Il 5 Direct Entry for Zone For the views 30 Zones 15 Zones 8 Zones 6 Zones 4 Zones 1 Zone the displayed setpoint actual value control deviation degree of operation and current can be selected directly for data entry 5 1 Direct Entry for Setpoint Value DEMO Act Value set point Zone 1 roe EE P120 7 120 Zone 16 By selection of the value for actual value or setpoint value or difference a window to enter setpoint value is displayed By the keypad displayed the new value is entered With the setting 3 DS the value is directly taken over With the setting rel the present value is changed by the value entered increased decreased Right to technical changes reserved Rev 1 00 02 11 12 Chapter 5 Direct Entry for Zone 5 2 Direct Entry for Degree of Operation DEMO Degree Of Operation on 13 23 eS a s a an Zone 12 Zone 13 Zone i4 Zone 15 EP Function Manual Mode Zone 1 Degree Of Operation Manual Mode By selection of the value for degree of operation the shown window is displayed By the buttons ON OFF the manual mode can be activated deactivated For manual mode active the new value for degree of operation can directly be entered 5 3 Direct Entry for Current DEMO Current A
24. th setting Button you can step through the views by each click on them With setting Menu a selection list is displayed where the view can be selected from Setting of unit C F The connected devices are adjusted to this setting Is degree of operation clicked on in the zone view and Direct input degree of operation ON the dialog Function manual mode zone X is called Is current clicked on in the zone view and Direct input current acceptance ON the dialog Current acceptance is called Node ID cw Timeout Baud Rate 250k BA PDO 2 Check of CAN Setup StartAllNodes z before communicaki Setup of the CAN interface An interface test is done by function check In case of correct interface setup the version of the software of the actual controller is displayed in the version field In case of incorrect communication an error message is displayed in the status field Right to technical changes reserved Rev 1 00 02 24 Chapter 8 Utility 8 2 2 Network configuration i TY Network Configuration Device Name VisioP4 gt o m Obtain an IP address via DHCP IP Address 192 fes f fz36 Subnet Mask 255 fz55 f255 o Gateway o b p b Primary DNS o b p b Secondary DNS o b p b Primary WINS o bP fo p Secondary WINS o bP p b Setting of network addresses Only required in case of external data storage by Ethernet 8 2 3 Information HRSTOUCH Copyright C 2005 Version L Plastic Servi
Download Pdf Manuals
Related Search
Related Contents
Finistère Penn-ar-Bed n°115 (pdf - 5,17 Mo) DEUMIDIFICATORE Istruzioni per l`installazione -Janis 普通便座施工説明書 Catálogo tarifa calefacción Beretta 2014 Whirlpool R8700PXS Oven User Manual none Y96591 Instructions / Assembly POP-M23GX MANUAL DE INSTRUCCIONES カタログ Printix Client Copyright © All rights reserved.