Home
NuVent NXMD1001ABUPS Instructions / Assembly
Contents
1. in the mounting bracket as a template Figure 4B mark on the motor plate the position of the holes Remove the mounting bracket Drill the four marked holes in the motor plate using a 1 8 drill bit FIGURE 4 AB 4A 4B 7 Attach the mounting bracket to the motor plate with four 1 2 pan head screws provided 8 Reinsert the motor plate in the housing and secure motor plate with motor plate screw removed in Step 4 9 Reinsert the motor quick connector 10 Insert the two 2 Phillips pan head screws provided in the mounting bracket See Figure 5 FIGURE 5 11 Insert the quick connector on the Designer Light frame into the same receptacle in the pre installed housing from which the old light assembly was disconnected in Step 3 12 Position the keyhole slots in the Designer Light frame over the two screws in the mounting bracket Twist in place and secure Designer Light frame by tightening screws in mounting bracket 13 Insert two 60W incandescent bulbs or two compact fluorescent bulbs into light sockets 14 Install glass dome Twist slightly to secure
2. A nuyent The NuVent Designer Light for use with Bath Fan listed in these instructions is designed for use as a fan light in the bathroom with any pre installed NuVent MR or MS Series fan light all of which use the M2000 Universal Housing The NuVent Designer Light may also be used as a separate light fixture SAFETY INSTRUCTIONS WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING 1 Use this unit only in the manner intended by the manufacturer It you have questions contact the manufacturer 2 Before servicing or cleaning unit switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel 3 Installation work and electrical wiring must be done by qualitied person s in accordance with all applicable codes and standards including fire rated construction and standards Turn OFF power and lock out service panel before installing or wiring this product It you are unfamiliar with methods of installing electrical wiring secure the services of a qualitied electrician 4 Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent backdratting Follow the heating equipment manufacturers guideline and safety standar
3. ds such as those published by the National Fire Protection Association NFPA and the American Society of Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities 5 When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities 6 Ducted fans must always be vented to the outdoors 7 NEVER place a switch where it can be reached trom a tub or shower 8 This unit must be grounded 9 This unit is UL listed Type I C inherently protected 10 This tan is not for use in kitchens 11 Acceptable for use over a bathtub or shower when installed in a GFCI protected circuit 12 Install fan at least 1 5m 5 feet above the floor CAUTION FOR GENERAL VENTILATING USE ONLY 1 Do not use to exhaust hazardous or explosive materials and vapors 2 This product is designed for installation in flat ceilings only Do not mount this product in a wall 3 The light fixture assembly must be mounted to the NuVent M2000 housing or to a wiring outlet box Designer Light for use with Bath Fan INSTALLATION INSTRUCTIONS Models NXMD1AB NXMD10OB NXMD1WH TOOLS REQUIRED FOR INSTALLATION e Screwdriver e Electric drill e 1 8 drill bit e Wire cutters e Wire stripper e UL approved wire nuts connectors PARTS LIST 1 Designer Light frame 1 Glass dome 1 Mounting bracket 2 21 2 Philips pan head screws 4 1 2 Philips pan head screws ES
4. i Note Not all of these parts will be used in these installations If you are missing parts please phone 800 433 1626 and ask for Customer Service INSTALLATION INSTRUCTIONS FOR USE AS A SEPARATE LIGHT FIXTURE WIRING This product requires 120v AC standard house wiring with ground from the power source through a standard wall switch Turn OFF power and lock out service panel before installing or wiring this product If you are unfamiliar with methods of installing electrical wiring secure the services of a qualified electrician 1 The NuVent Designer Light has a pre installed quick connector that will not be used when the Designer Light is used as a separate light fixture Before beginning installation the quick connector must be removed IMPORTANT Do not cut these wires if you intend to use the designer light with a fan For that use follow instructions on the reverse side of this page Using a wire cutter cut each of the three wires white black and green next to the quick connector See Figure 1 FIGURE 1 2 Remove the ground wire green from the Designer Light trame by removing the grounding screw Store screw safely until needed in Step 4 below 3 Using a wire stripper remove approximately 1 2 of insulation from the black and white wires on the Designer Light 4 Connect the supply wiring to the designer light wiring using UL approved connectors black to black and white to white Connect gro
5. und wire from the supply to the Designer Light frame using grounding screw removed in Step 2 5 Mount Designer Light trame to ceiling box using the two mounting screws provided NuVent is the Bath and Kitchen Ventilation product line from Ventamatic Ltd 100 Washington St Mineral Wells TX 76067 Phone 800 433 1626 Fax 940 325 9311 INSTALLATION INSTRUCTIONS FOR USE WITH BATH FAN The NuVent Designer Light Models NXMD1AB NXMD10 B and NXMD1WH is designed to be used with any pre installed NuVent MR or MS Series tan light all of which use the M2000 Universal Housing For installation as a separate light fixture see previous page 1 The NuVent Designer Light frame has a pre installed center bolt that will not be used in this installation Remove 2 Remove the grille trom the pre installed NuVent fan light Note On units manufactured prior to 2005 the grille is mounted to the housing with torsion springs on units manufactured during or after 2005 the grille light assembly is mounted to the housing with a hex screw 3 Unplug the light assembly quick connector See Figure 1 FIGURE 1 4 Remove the motor plate screw Figure 2A Store screw sately until needed in Step 8 Remove the motor quick connector Figure 2B FIGURE 2 2A 2B 6 Place the motor plate on a bench or other flat surface Center the mounting bracket provided on the motor plate See Figure 4A Using the four pre drilled holes
Download Pdf Manuals
Related Search
Related Contents
Actiontec SW501R Owner's Manual 取扱説明書 Sensorless Brushless dc Motor Using the MC68HC908MR32 Samsung SMART CAMERA SH100 Bruksanvisning USER`S MANUAL Samsung MD230 Brugervejledning Manual de Instruções - Metalúrgica Siemsen Handbook PO-106, Automated Postal Center (APC) Program A-Rival NAV-PNF50 C Copyright © All rights reserved.