1. 13 Using a good grade of roofing cement material seal all of the shingles and heads of nails DO NOT seal the bottom edge of the flashing Page 4 WIRING IMPORTANT Do not mount outlet box near heat source 1 Mount the outlet box to a nearby rafter so that the outlet box is higher than the fan motor CAUTION Make sure fan and switches are properly BLACK BLACK FROM MOTOR FROM HOUSE FROM FAN MOTOR WHITE FROM MOTOR AND HOUSE CABLE grounded and all wiring complies with local electrical code requirements 2 Remove the thermostat wiring box cover plate Bring 120 VAC 14 gauge with ground house power cable at least 6 into the thermostat wiring box Fasten cable to box with appropriate connector 3 An on off switch can be installed in a convenient location in the living area of the house so that the fan can be turned off when not needed ADJUSTING THE THERMOSTAT FAN ON TEMPERATURE O O 700 H Tun 110 1200 60 500 E The fan thermostat is preset to 110 F The fan will automatically start when the ambient temperature reaches the set temperature and stop when the temperature drops 10 degrees below the set temperature The start temperature can be adjusted from 60 F to 120 F BROAN MODEL 349BR SERVICE PARTS Page 5 KEY NO PART NO DESCRIPTION 0705B 000 0706B 000 0707B 000 0708B 000 0709B 000 0710B 000 0711B 000 Cover Motor Blade Conduit Motor
2. 3 requises 0710B 000 Grillage aviaire 0711B 000 Ensemble de boitier de thermostat SSE ESS j 0 NN e ul d i Y y GARANTIE l V i i d d ILE Garantie limit e de un an GARANTIE DU PROPRIETAIRE Broan NuTone garantit a l acheteur original de ses produits que ces derniers seront exempts de tout d faut de mat riaux et de fabrication pour une p riode de un 1 an a compter de la date d achat AUCUNE AUTRE GARANTIE IMPLICITE OU EXPRESSE N EST DONNEE Y COMPRIS MAIS SANS S Y LIMITER GARANTIE DE MARCHANDIBILITE OU D ADAPTATION A UN USAGE PARTICULIER Pendant cette p riode d un an Broan NuTone proc dera au remplacement ou a la reparation sans aucuns frais mais a sa propre discr tion de tout produit ou piece jug d fectueux dans le cadre d une utilisation normale CETTE GARANTIE NE COUVRE PAS LES STARTERS DE TUBES FLUORESCENTS LES FLUORESCENTS LES FILTRES CONDUITS CAPUCHONS DE MUR OU DE TOIT ET AUTRES ACCESSOIRES D INSTALLATION Cette garantie ne couvre pas a Pentretien et le service courants ni b les produits et les pi ces ayant fait l objet d un usage abusif de n gligence d un accident d un entretien ou d une r paration non appropri e par du personnel non
3. Au moment de la demande de service sous garantie vous devez fournir une preuve de la date d achat originale Broan NuTone LLC Hartford Wisconsin www broan com 800 558 1711 Broan NuTone Canada Mississauga Ontario www broan ca 877 896 1119 BROS MODELO 349BR VENTILADOR EL CTRICO PARA TICO MONTADO EN EL TECHO P gina 11 ADVERTENCIA A PARA REDUCIR EL RIESGO DE INCENDIOS DESCARGAS EL CTRICAS O LESIONES PERSONALES OBSERVE LAS SIGUIENTES PRECAUCIONES 1 Use la unidad solo de la manera indicada por el fabricante Si tiene preguntas comun quese con el fabricante a la direcci n o al numero telef nico que se incluye en la garant a 2 Antes de dar servicio a la unidad o de limpiarla interrumpa el suministro el ctrico en el panel de servicio y bloquee los medios de desconexi n del servicio para evitar que la electricidad se reanude accidentalmente Cuando no sea posible bloquear los medios de desconexi n del servicio fije firmemente una se al de advertencia como una etiqueta en un lugar visible del panel de servicio 3 Unaom s personas calificadas deben realizar el trabajo de instalaci n y el cableado el ctrico de acuerdo con todos los c digos y normas correspondientes incluidos los c digos y normas de construcci n espec ficos de protecci n contra incendios 4 Se necesita suficiente aire para que se lleve a cabo una combusti n y una extracci n adecuadas de los g
4. GARANTIA Para tener derecho al servicio de garant a usted debe a notificar a Broan NuTone a la direcci n o al n mero de tel fono indicado abajo b indicar el n mero de modelo y la identificaci n de la parte y c describir la naturaleza de cualquier defecto en el producto o parte Al momento de solicitar el servicio por la garant a usted debe presentar un comprobante de la fecha original de compra Broan NuTone LLC Hartford Wisconsin www broan com 800 558 1711 Broan NuTone Canada Mississauga Ontario www broan ca 877 896 1119 99527122A
5. autoris par Broan NuTone d une mauvaise installation ou d une installation non conforme aux directives d installation fournies La dur e de toute garantie implicite est limit e la p riode de un an pr cis e pour la garantie expresse Certains Etats ne reconnaissent pas les restrictions relatives a la dur e des garanties implicites il se pourrait donc que cette restriction ne s applique pas dans votre cas LE REMPLACEMENT OU LA REPARATION PAR BROAN NUTONE A SA PROPRE DISCRETION DE TOUT PRODUIT OU PIECE DEFECTUEUX CONSTITUE LE SEUL REMEDE DE L ACHETEUR EN VERTU DE CETTE GARANTIE BROAN NUTONE NE PEUT ETRE TENUE RESPONSABLE DES DOMMAGES INDIRECTS CONSECUTIFS OU SPECIAUX ATTRIBUABLES A UTILISATION OU AU RENDEMENT DU PRODUIT Certains Etats ne reconnaissent pas les restrictions ni les exclusions relatives aux dommages indirects cons cutifs ou sp ciaux il se pourrait donc que cette restriction ne s applique pas dans votre cas La pr sente garantie vous accorde des droits sp cifiques mais vous pourriez aussi avoir d autres droits en fonction de l Etat dans lequel vous r sidez Cette garantie remplace toute autre garantie donn e pr c dement SERVICE SOUS GARANTIE Pour tre admissible au service sous garantie vous devez a aviser Broan NuTone l adresse ou au num ro de t l phone ci dessous b fournir le num ro du mod le et la description de la pi ce et c d crire la nature du d faut de la pi ce ou du produit
6. lieux expos s une forte pollution industrielle de l air Suivez les directives du fabricant de la peinture pour obtenir une bonne adh rence Ce ventilateur est con u pour tre install sur un toit Le ventilateur de pignon Broan mod le 353 est disponible pour les applications murales Le d me peut tre peint avec une peinture de qualit sup rieure Suivez les recommandations du fabricant de la peinture pour l acier enduit d un rev tement en poudre Veuillez lire l tiquette de sp cifications du produit pour obtenir plus de renseignements notamment sur les exigences Barre clous pour enlever les clous toiture Clous toiture galvanis s de 4 4 cm 1 po min Accessoires d alimentation lectrique conformes aux codes en vigueur BRSAN MODELE 349BR Page 7 INSTALLATION HL tt ga mm marre treated A et o EL SSS ET PRES qq nee A A PE EER REP PP PR om AA ia PP A mme Ca lh a ESS AS RP oo AE PR 1 Choisissez un emplacement pour le ventilateur au centre du toit sur la pente arri re Placez le le plus haut possible sur le toit l emplacement doit tre exempt d obstacles fils de t l viseur lignes lectriques etc Sile dessus du ventilateur est au m me niveau que le faite du toit il ne pourra pas tre aper u de la rue Gardez cet emplacement en t te pendant que vous travaillez partir du grenier ar I E Lo Lo Lo oo Lo A 5 Enfoncez un gros clou au c
7. ventilador cuando no se necesite AJUSTE DEL TERMOSTATO FAN ON TEMPERATURE O 0 700 H Tun 110 1200 60 500 Sch El termostato del ventilador esta preajustado a 110 F 43 C El ventilador encendera automaticamente cuando la temperatura ambiente llegue a la temperatura establecida y se detendra cuando la temperatura quede 10 grados por abajo de la temperatura establecida La temperatura de arranque se puede ajustar de 60 F a 120 F 16 a 49 C BRSAN MODELO 349BR Pagina 15 PIEZAS DE SERVICIO 0705B 000 Cubierta 0706B 000 Motor 0707B 000 Hoja 0708B 000 Conducto 0709B 000 Soporte de montaje del motor se requieren 3 0710B 000 Malla para pajaros 0711B 000 Conjunto del termostato de la caja de conexiones gt a 6 GARANT A Garant a limitada de un a o GARANT A DEL PROPIETARIO Broan NuTone garantiza al comprador consumidor original de sus productos por un per odo de un 1 a o desde la fecha original de compra que tales productos est n libres de defectos en material y mano de obra NO HAY OTRAS GARANTIAS EXPRESAS 0 IMPLICITAS INCLUYENDO ENTRE OTRAS GARANTIAS IMPLICITAS DE COMERCIALIZACION O ADAPTABLES A UN PROPOSITO EN PARTICULAR Durante este per odo de un a o Broan NuTone reparar o reemplazar a su opci n y sin costo cualquier producto o parte que se encuentre defectuoso bajo condiciones normales de uso y servicio ESTA GARANTIA NO CUBRE A LOS ARRANCA
8. vents are under the eaves with direct access to the attic Failure to provide these intakes could cause natural draft gas appliances to backdraft Your attic fan installation will create a screened opening into your attic space During a heavy rain storm there could be a light spray of rain into this attic space This is a normal condition with all attic ventilators and will not cause any damage to the structure We recommend that you do not store any valuable articles directly under the fan opening in the roof During extreme rain and wind storms you may want to turn on your attic ventilator to prevent excess moisture accumulation in your attic Records show under ideal conditions exposed galvanized steel can remain rust free up to 100 years For best protection the exposed portion of the roof sheet should be painted especially in areas of unusually high industrial air pollution Follow paint manufacturer s instructions for good adhesion This ventilator is intended for roof installation The Broan Model 353 Gable Mount Ventilator is available for side wall applications The dome may be painted with a high quality paint Follow the paint manufacturer s recommendations for powder coated steel Please read specification label on product for further information and requirements Pry Bar to remove roofing nails Galvanized Roofing Nails 134 min Electrical Supplies to comply with codes BRSAWN MODEL 349BR Page 2 INSTALLATI
9. BROAN MODEL 349BR ROOF MOUNT POWERED ATTIC VENTILATOR Page 1 WARNING A TO TO 1 TOOLS AND MATERIALS REQUIRED DODODO REDUCETHE RISK OF FIRE ELECTRIC SHOCK OR INJURY PERSONS OBSERVE THE FOLLOWING Use this unit only in the manner intended by the manufacturer If you have questions contact the manufacturer at the address or telephone number listed in the warranty Before servicing or cleaning unit switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel Installation work and electrical wiring must be done by a qualified person s in accordance with all applicable codes and standards including fire rated construction codes and standards Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent backdrafting Follow the heating equipment manufacturer s guidelines and safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAB and the local code authorities When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities The wiring must be permanent D
10. DORES PARA LAMPARAS FLUORESCENTES O A LOS TUBOS FLUORESCENTES FILTROS CONDUCTOS TAPAS DE TECHO TAPAS DE PARED Y OTROS ACCESORIOS PARA CANALIZACION Esta garant a no cubre a Mantenimiento y servicios normales ni b Productos o partes sujetos al mal uso negligencia accidente mantenimiento inadecuado o reparaciones por otros ajenos a Broan NuTone instalaci n defectuosa o una instalaci n contraria a las instrucciones de instalaci n recomendadas La duraci n de cualquier garant a impl cita est limitada a un periodo de un a o seg n se especifica en la garant a expresa Algunos estados no permiten limitaci n en cuanto a la duraci n de una garant a impl cita por lo que la limitaci n arriba indicada puede que no se apliqu a usted LA OBLIGACION DE BROAN NUTONE DE REPARAR O REEMPLAZAR A SU OPCION SERA EL UNICO Y EXCLUSIVO RECURSO QUE TENDRA EL COMPRADOR BAJO ESTA GARANTIA BROAN NUTONE NO SERA RESPONSABLE POR DANOS INCIDENTALES CONSECUENTES O ESPECIALES QUE RESULTEN A CONSECUENCIA O SEAN INDEPENDIENTES DEL USO O DESEMPENO DEL PRODUCTO Algunos estados no permiten la exclusi n o limitaci n de da os incidentales o consecuentes de modo que la limitaci n o exclusi n arriba indicada pueda que no se aplique a usted Esta garant a le proporciona derechos legales espec ficos y usted podr a tener otros derechos los cuales var an de un estado a otro Esta garant a reemplaza a todas las garant as anteriores SERVICIO DE
11. EMEDY UNDER THIS WARRANTY BROAN NUTONE SHALL NOT BE LIABLE FOR INCIDENTAL CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from State to state This warranty supersedes all prior warranties WARRANTY SERVICE To qualify for warranty service you must a notify Broan NuTone at the address or telephone number below b give the model number and part identification and c describe the nature of any defect in the product or part At the time of requesting warranty service you must present evidence of the original purchase date Broan NuTone LLC Hartford Wisconsin www broan com 800 558 1711 Broan NuTone Canada Mississauga Ontario www broan ca 877 896 1119 i Wi i oy Ess q d d EE BROS MODELE 349BR VENTILATEUR ELECTRIQUE DE GRENIER MONTE SUR LE TOIT Page 6 LIRE CES DIRECTIVES ET LES CONSERVER AVERTISSEMENT A AFIN DE DIMINUER LES RISQUES D INCENDIE D ELECTROCUTION OU DE BLESSURES SUIVEZ CES DIRECTIVES 1 N utilisez cet appareil que de la mani re pr vue par le fabricant Si vous avez des questions c
12. Mounting Bracket 3 req Bird Screen Outlet Box Thermostat Assembly WARRANTY One Year Limited Warranty WARRANTY OWNER Broan NuTone warrants to the original consumer purchaser of its products that such products will be free from defects in materials or workmanship for a period of one 1 year from the date of original purchase THERE ARE NO OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE During this one year period Broan NuTone will at its option repair or replace without charge any product or part which is found to be defective under normal use and service THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS OR TUBES FILTERS DUCT ROOF CAPS WALL CAPS AND OTHER ACCESSORIES FOR DUCTING This warranty does not cover a normal maintenance and service or b any products or parts which have been subject to misuse negligence accident improper maintenance or repair other than by Broan NuTone faulty installation or installation contrary to recommended installation instructions The duration of any implied warranty is limited to the one year period as specified for the express warranty Some states do not allow limitation on how long an implied warranty lasts so the above limitation may not apply to you BROAN NUTONE S OBLIGATION TO REPAIR OR REPLACE AT BROAN NUTONE S OPTION SHALL BE THE PURCHASER S SOLE AND EXCLUSIVE R
13. O NOT USE AN EXTENSION CORD Use 14 GA MINIMUM copper wire Although the Powered Attic Ventilator may be wired directly to power we advise that some type of shut off switch be installed in the line Please see the section on electrical wiring for suggested wiring diagrams and instructions To reduce the risk of electric shock do not use this fan with any solid state speed control device This unit must be grounded Pencil Utility Knife Slotted Screwdriver Drill 1 4 Drill Bit Sabre Saw or Keyhole Saw Hammer Ruler Roofing Cement DODODO eae For general ventilating use only Do not use to exhaust hazardous 10 or explosive materials and vapors To avoid motor bearing damage and noisy and or unbalanced impellers keep drywall spray construction dust etc off power unit This unit has an unguarded impeller Do not use in locations readily accessible to people or animals Fan is equipped with a thermostat which may start fan automatically To reduce risk of injury or electric shock while servicing or cleaning unit switch power off at service panel and lock service panel to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel Home Ventilating Institute HVI recommends one square foot of open air inlet per 300 cfm of fan capacity The best location for these air intake
14. ON 1 Locate the ventilator at the center of the rear slope of the roof Place it as high on the roof as possible The location should be free of obstacles T V leads electrical lines etc If the ventilator top is level with the roof peak it can t be seen from the street Keep this approximate location in mind as you work from within the attic EL JC E E E EE EE EE IE E E 5 Push a large nail through the center of the cardboard template and into the guide hole Using the large half of the template draw a 17 3 8 diameter 2 Mark a spot halfway between rafters circle on the shingles MODEL 349BR Page 3 6 Cut out the shingles inside of the circle 9 Cut out the roof board s inside of the line Do not cut rafters 10 For proper removal of roofing nails draw a 25 3 8 square 7 Replace template over guide hole and draw a 14 centered around the hole Remove nails holding shingles 7 s diameter circle on the black paper or roof boards using down from top two thirds of square the smaller half of the template 11 Slide the flashing under the shingles Start two thirds of the way down from the top of the 25 3 s square Do 8 Drill a large starting hole for the sabre saw just inside of not bend the shingles any more than necessary Center the line the ventilator over the hole MODEL 349BR 12 Carefully lift shingles and nail flashing securely to the roof using galvanized roofing nails
15. a dos tercios desde la parte superior del cuadro de 8 Perfore un orificio iniciador grande para la sierra de vaiv n 25 3 8 pulg 63 6 cm No doble las tejas m s de lo justo dentro de la l nea necesario Centre el ventilador sobre el orificio MODELO 349BR 12 Levante con cuidado las tejas y clave el cubrejuntas firmemente al techo usando clavos galvanizados para techo 13 Con un buen cemento con grado para techo selle todas las tejas y cabezas de clavos NO selle el borde inferior del cubrejuntas P gina 14 CABLEADO IMPORTANTE No monte la caja de conexiones cerca de la fuente de calor 1 Monte la caja de conexiones en una viga cercana para que la caja est m s alta que el motor del ventilador NEGRO DEL CABLE DE LA CASA NEGRO DEL DEL MOTOR PE e VENTILADOR LA CASA BLANCO DEL MOTOR Y DEL CABLE DE LA CASA PRECAUCI N Aseg rese de que el ventilador y los interruptores est n bien conectados a tierra y que todo el cableado cumpla con los requisitos del c digo el ctrico local 2 Quite la placa de cubierta de la caja de cableado del termostato Lleve el cable el ctrico de 120 VCA calibre 14 con tierra de la casa por lo menos a 6 pulg 15 2 cm de la caja de cableado del termostato Sujete el cable a la caja con el conector adecuado 3 Se puede instalar un interruptor de encendido apagado en un sitio conveniente del rea de estar de la casa de tal manera que se pueda apagar el
16. ases a trav s del tubo de humos chimenea del equipo quemador de combustible con el fin de evitar el contratiro Siga las directrices y las normas de seguridad del fabricante del equipo de calefacci n como las publicadas por la Asociaci n Nacional de Protecci n contra Incendios National Fire Protection Association NFPA y la Sociedad Americana de Ingenieros en Calefacci n Refrigeraci n y Aire Acondicionado American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAB y las autoridades de los c digos locales 5 Al cortar o perforar a trav s de la pared o del techo tenga cuidado de no da ar el cableado el ctrico ni otros servicios ocultos 6 El cableado debe ser permanente NO UTILICE UNA EXTENSI N EL CTRICA Utilice cable de cobre MINIMO de 14 GA Aunque el ventilador el ctrico para tico puede cablearse directo a la electricidad le aconsejamos que instale en la l nea alg n tipo de interruptor de apagado Vea los diagramas de cableado e instrucciones sugeridas en la secci n del cableado el ctrico 7 Para reducir el riesgo de descargas el ctricas no use este ventilador con ning n dispositivo de control de velocidad de estado s lido 8 Esta unidad debe conectarse a tierra PRECAUCI N A 1 10 S lo para usarse como medio de ventilaci n general No debe usarse para la extracci n de materiales ni vapores peligrosos o explosivos Para evitar da os a los cojinetes del motor y
17. entre du gabarit en carton et dans l avant trou En vous servant de la grande moiti du gabarit tracez un cercle de 43 3 cm 17 3 8 po de diam tre sur les bardeaux 2 Tracez un rep re au milieu des chevrons du toit MODELE 349BR Page 8 6 Taillez les bardeaux a l int rieur du cercle 9 Coupez le ou les panneaux du toit l int rieur de la ligne Ne coupez pas les chevrons 10 Pour enlever correctement les clous du toit tracez un 7 Replacez le gabarit sur l avant trou et tracez un cercle de carr de 63 6 cm 25 3 8 po centr autour de l ouverture 35 7 cm 14 7 8 po de diam tre sur le papier goudron ou Enlevez les clous des bardeaux du haut jusqu au deux le panneau du toit l aide de la petite moiti du gabarit tiers du carr 11 Glissezle solin sous les bardeaux Commencez au deux tiers du carr de 63 6 cm 25 3 s po a partir du haut 8 Percez un grand trou de d part pour la scie sauteuse Ne pliez pas les bardeaux plus que n cessaire Centrez juste a l int rieur de la ligne le ventilateur sur louverture MODELE 349BR 12 Soulevez d licatement les bardeaux et clouez solidement le solin au toit a l aide de clous a toiture galvanis s 13 Imperm abilisez tous les bardeaux et les t tes de clou a Paide d un enduit a toiture de bonne qualit N IMPERMEABILISEZ PAS le bord inf rieur du solin Page 9 CABLAGE IMPORTANT Ne fixez pas la boite lectrique p
18. il de cuivre de calibre 14 Bien que le ventilateur lectrique de grenier puisse tre directement raccord a la source lectrique nous conseillons d installer un interrupteur ou dispositif semblable sur la ligne Veuillez consulter la section sur le c blage lectrique pour les sch mas de c blage sugg r s et les instructions 7 Pourr duire les risques de choc lectrique n utilisez pas de commande de regime a semi conducteurs avec ce ventilateur 8 Cet appareil doit tre reli a une mise a la terre OUTILS ET MATERIEL REQUIS Tournevis plat Crayon Perceuse Meche de 6 4 mm 1 4 po Scie sauteuse ou scie passe partout Enduit a toiture Marteau DODODO DODODO Regle Couteau universel ATTENTION 1 2 10 Cet appareil ne doit servir qu la ventilation g n rale Ne Putilisez pas pour l vacuation de mati res ou de vapeurs dangereuses ou explosives Pour viter d endommagerles roulements de moteur de d s quilibrerles pales ou de les rendre bruyantes d barrassez l appareil de la poussi re de pl tre de construction etc Cet appareil comporte une h lice non prot g e Ne Putilisez pas dans un endroit facilement accessible aux personnes ou aux animaux Le ventilateur est dot d un thermostat qui peut le faire d marrer automatiquement Pour r duire les risques de blessure ou de choc lectrique lors de l entretien ou du nettoyage de l appareil coupez l alimentation du pannea
19. ommuniquez avec le fabricant adresse ou au num ro de t l phone indiqu s dans la garantie 2 Avant de proc der l entretien ou au nettoyage de l appareil coupez l alimentation du panneau lectrique et verrouillez l interrupteur principal afin d emp cher que le courantne soit accidentellement r tabli S ilestimpossible de verrouiller l interrupteur principal fixez solidement un message d avertissement par exemple une tiquette sur le panneau lectrique 3 La pose de l appareil et les travaux d lectricit doivent tre effectu s par des personnes qualifi es conform ment la r glementation en vigueur notamment les normes de la construction ayant trait la protection contre les incendies 4 Pour viter les refoulements l apport d air doit tre suffisant pour br ler les gaz produits par les appareils combustion et les vacuer dans le conduit de fum e chemin e Respectez les directives du fabricant de l appareil de chauffage et les normes de s curit notamment celles publi es par la National Fire Protection Association NFPA American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE et les codes des autorit s locales 5 Veillez a ne pas endommager le cablage lectrique ou d autres quipements non apparents lors de la d coupe ou du percage du mur ou du plafond 6 Le c blage doit tre permanent N UTILISEZ PAS DE RALLONGE ELECTRIQUE Utilisez au MINIMUM un f
20. res d une source de chaleur 1 Fixez la boite lectrique plus haute que le moteur du ventilateur Sur un chevron voisin CABLE DE LA CABLE DE DU MOTEUR DU LA MAISON VENTILATEUR BLANC DU MOTEUR ET DU CABLE DE LA MAISON ATTENTION Assurez vous que le ventilateur et l interrupteur sont correctement mis la terre et que le c blage est conforme aux exigences du code local de l lectricit 2 Enlevez le couvercle du bo tier de connexion du thermostat Enfilez un c ble de 120 VCA de calibre 14 avec mise a la terre d au moins 15 2 cm 6 po a l int rieur de la bo te de connexion du thermostat Fixez le cable a la boite avec un connecteur appropri 3 Un interrupteur marche arr t peut tre install a un endroit pratique dans la partie habitable de la maison afin de pouvoir arr ter le ventilateur au besoin REGLAGE DU THERMOSTAT FAN ON TEMPERATURE O O e H Tun 110 1200 60 500 Le thermostat du ventilateur est pr r gl 43 C 110 F Le ventilateur d marre automatiquement lorsque la temp rature atteint le point de consigne et s arr te lorsque la temp rature chute de 10 degr s en de du point de consigne La temp rature de d marrage peut tre r gl e de 16 49 C 60 F 120 F BRSAWN MODELE 349BR Page 10 PIECES DE RECHANGE 0705B 000 Couvercle 0706B 000 Moteur 0707B 000 H lice 0708B 000 Tube 0709B 000 Bride de montage de moteur
21. res de tico y no provocar da os a la estructura Le recomendamos que no guarde art culos valiosos directamente debajo de la abertura del ventilador en el techo Durante lluvia y viento extremos tal vez quiera encender el ventilador para tico para prevenir que se acumule un exceso de humead en su tico Los registros muestran que bajo condiciones ideales el acero galvanizado expuesto puede mantenerse libre de corrosi n hasta por 100 a os Para tener la mejor protecci n la parte expuesta de la hoja del techo debe pintarse en especial en reas con una contaminaci n del aire por ambiente industrial que sea inusualmente alta Siga las instrucciones del fabricante de la pintura para tener buena adhesi n Esta ventilaci n est dirigida para instalarse en eltecho El ventilador para montaje en hastial Broan modelo 353 est disponible para aplicaciones de muros laterales El domo se puede pintar con pintura de alta calidad Siga las recomendaciones del fabricante de la pintura para el acero con recubrimiento pulverizado Lea la etiqueta de especificaciones que tiene el producto para ver informaci n y requisitos adicionales HERRAMIENTAS Y MATERIALES REQUERIDOS Desarmador plano L piz Taladro Navaja utilitaria Broca para taladro de 1 4 pulg 6 4 mm Sierra de vaiv n o sierra caladora Martillo Regla DODODO DODODO Cemento para techo Barra de palanca para quitar los clavos del techo Clavos galvanizados para
22. rotores ruidosos o desbalanceados mantenga la unidad de potencia protegida contra rociados de yeso polvos de construcci n etc Esta unidad tiene un impulsor sin protecci n No lo use en sitios f cilmente accesibles para personas o animales El ventilador est equipado con un termostato que puede encender autom ticamente el ventilador Para reducir el riesgo de incendio o de descarga el ctrica al dar servicio o limpiar la unidad interrumpa el suministro el ctrico en el panel de servicio y bloquee el panel de servicio para evitar que se active accidentalmente la electricidad Cuando no sea posible bloquear los medios de desconexi n del servicio fije firmemente una se al de advertencia como una etiqueta en un lugar visible del panel de servicio El Instituto de Ventilaci n de la Vivienda Home Ventilation Institute HVI recomienda un pie cuadrado de entrada de aire abierto por 300 pies min 8 5 cm min de capacidad del ventilador La mejor ubicaci n para estas ventilaciones de admisi n de aire es debajo de los aleros con acceso directo al tico De no suministrar estas entradas se podr a ocasionar que se invierta la corriente natural de los electrodom sticos de gas La instalaci n de su ventilador para tico crear una abertura con malla en su espacio de tico Si hubiera una lluvia muy intensa podr a provocarse un ligero rociado de la lluvia en este espacio del tico Esta situaci n es normal con todos los ventilado
23. techo de 1 pulg 4 4 cm m n Suministros el ctricos para cumplir con los c digos BROAN MODELO 349BR INSTALACION 1 Ubique el ventilador en el centro de la pendiente posterior del techo Col quelo tan alto en el techo como sea posible La ubicaci n debe estar libre de obst culos cables de televisi n l neas el ctricas etc Si la parte superior del ventilador est a nivel con el pico del techo no se puede ver desde la calle Tome en cuenta esta ubicaci n aproximada mientras trabaja desde el tico 2 Marque un punto a media distancia entre las vigas del techo P gina 12 5 Empuje un clavo largo a trav s del centro de la plantilla de cart n y en el orificio gu a Usando la mitad grande de la plantilla dibuje un c rculo de 17 3 8 pulg 43 3 cm de di metro en las tejas MODELO 349BR Pagina 13 6 Recorte las tejas dentro del circulo 9 Recorte las tablas del techo dentro de la linea No corte las vigas 10 Para poder quitar adecuadamente los clavos del techo 7 Reemplace la plantilla sobre el orificio guia y dibuje un dibuje un cuadro de 25 3 s pulg 63 6 cm centrado c rculo de 14 7 8 pulg 35 7 cm de di metro en el papel alrededor del orificio Retire las tejas que sostienen los negro o las tablas del techo usando la mitad mas peque a clavos desde los dos tercios superiores del cuadro de la plantilla 11 Deslice el cubrejuntas debajo de las tejas Inicie
24. u lectrique et verrouillez l interrupteur principal afin d emp cher que le courant ne soit accidentellement r tabli S il est impossible de verrouiller l interrupteur principal fixez solidement un message d avertissement par exemple une tiquette sur le panneau lectrique Le Home Ventilating Institute HVI recommande une entr e dar de un pied carr pour un ventilateur d une capacit de 8 5 cm min 300 pi min Le meilleur emplacement pour ces entr es d air est situ sous l avant toit aux endroits acc dant directement au grenier N gliger d installer de tels vents risque d entrainer le refoulement des gaz des appareils de combustion L installation cr era une ouverture grillag e acc dant l espace du grenier Lors d un orage violent une fine bruine de pluie pourrait p n trer dans le grenier Ceci est normal pour tous les ventilateurs de grenier et nentrainera aucun dommage la structure Nous vous conseillons de ne pas ranger d objets de valeur directement sous louverture du ventilateur dans le toit Lors d une forte pluie ou par temps tr s venteux vous pouvez actionner le ventilateur pour emp cher une accumulation excessive d humidit dans le grenier Les donn es indiquent que dans des conditions id ales l acier galvanis expos peut rester exempt de rouille jusqu cent ans Pour la meilleure protection la partie expos e de la t le de toiture devrait tre peinte particuli rement dans les