Illumine CLI-EMM022067 Instructions / Assembly
Contents
1. e au niveau du disJoncteur boitier de fusibles avant de commencer le c blage Tout le c blage doit tre conforme aux codes nationaux et locaux et le ventilateur de plafond doit tre mis la terre de facon correcte pour viter tout risque de d charge lectrique AA WARNING To avoid fire or shock follow all wiring Instructions carefully Any electrical work not described in these instructions should be done or approved by a licensed electrician AA AVERTISSEMENT Suivez solgneusement toutes les instructions de c blage pour viter tout risque d incendie ou de choc lectrique Tout travail lectrique qui n est pas d crit dans ces Instructions dolt tre effectu ou approuv par un lectricien professionnel
2. fan blades One hanger bali downrod assembly One hanger bracket One glass globe One fan light remote control transmitter One coupler cover Four 13 watt GU 24 fluorescent lamps One loose parts bag containing 1 Sixteen 3 16 24 x 1 2 slotted Phillips washer head blade screws Three wire connectors Two 1 1 4 threaded studs Two lockwashers Two knurled knobs a b 5 5 f g h i j k One hairpin clip One 1 25A 125V fuse spare One 5 32 32 x 375 pan head screw spare 2 3 4 5 6 One clevis pin 7 8 9 10 One 5 32 32 x 75 slotted head screw spare AA AVERTISSEMENT NOTE Place the parts from the loose parts bags Ce produit est con u pour un emploi exclusif avec les in a small container to keep them from being lost pi ces fournies avec ce produit et ou avec des If any parts are missing contact your local retailer accessoires d sign s sp cifiquement pour emploi avec Of Catalog outlet for replacement before ce produit par Emerson Electric Co La substitution de proceeding pl ces ou d accessoires n ayant pas t d sign s pour emploi avec ce prodult par Emerson Electric Co pourrait causer des blessures ou des dommages mat riels Unpacking continued Remove the fan assembly from the protective plastic bag Place the fan assembly into the upper foam pad with the top of the motor facing up The upper foam pad serves as a holder for the fan during the first stage
3. CREW 3 CLEVIS i PIN b HAIRPIN SETSCREW HAIR MOTOR COUPLING Figure 3 How to Put Your Ceiling Fan Together continued Reinstall the hanger ball Figure 4 on the downrod as follows Route the motor leads through the downrod Position the pin through the two holes in the downred and align the ball so the pin is captured in the groove in the top of the hanger ball Pull the hanger ball up tight against the pin and securely tighten the setscrew in the hanger ball A loose setscrew could create fan wobble A WARNING It Is critical that the pin in the hanger ball is properly installed and the setscrew securely tightened Failure to verify that the pin and setscrew are properly installed could result in the fan falling AA AVERTISSEMENT Figure 4 li est cruclal que l axe dans le cylindre de suspension soit install correctement et que la vis de blocage soit bien serr e Si vous ne vous assurez pas que l axe et la vis sont install s correctement le ventilateur risquerait de tomber BLADE SLOT IN HOUSING The fan comes with black and white leads that A A J sneoix 1 2 SLOTTED are 80 long Before installing fan measure up n LEG BLADE SCREWS T approximately 6 to 9 inches above top of hanger N ball downrod assembly Cut off excess leads and qu FAN BLADE strip back insulation 1 2 inch from end of leads j Turn fan assembly upside down in preparation for mounting fan blades To ensure proper blade as
4. READ AND SAVE THESE INSTRUCTIONS 54 Ceiling Fan Owner s Manual Net Weight 22 1 Lbs 6 AA WARNING AVERTISSEMENT WARNING To avoid fire shock and serious personal injury follow these instructions AVERTISSEMENT suivez ces instructions pour ne pas risquer de causer un incendie un choc lectrique ou des blessures graves Safety Instructions Read your owner s manual carefully and keep it for future reference Before servicing or cleaning unit switch power off at service panel and lock service panel disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a warning device such as a tag to the service panel Be careful of the fan and blades when cleaning painting or working near the fan Always turn off the power to the ceillng fan before servicing Do not put anything into the fan blades while they are turning Do not operate reversing switch until fan blades have come to a complete stop Additional Safety Instructions for Installation To avoid possible shock be sure electricity is turned off at the fuse box before wiring and do not operate fan without blades All wiring must be in accordance with the National Electrical Code ANSI NFPA 70 2008 and Local Electrical Codes Use the National Electrical Code if Local Codes do not exlst The ceiling fan must be grounded as a precaution against possible electrical shoc
5. You should record this data above and keep it in a safe place for future use EMERSON QUIGK START GUIDE The Quick Start Guide covers the installation instructions common for ceillng fan operations If additional assistance with wlring alternate hanging systems or lighting options proceed to the complete Instructions of this Owner s Manual The Quick Start Guide sections include page numbers to correspond with the approprlate sections of the Owner s Manual for detalled Instructions See Unpacking Instructions for a complete list of parts for installatlon Installation of Downrod page 76 Remove the hanger ball from the downrod Install the downrod to the motor coupling using the clevis pin and hairpin clip Tighten the setscrews Turn fan assembly upside down in preparation for mounting fan blade assemblies TO ensure proper blade assembly make sure the label on the blades are facing the bottom of the ceiling fan Slide blade through center slot in fan housing Mount blade to fan housing using three 3 16 24 x 1 2 slotted Phillips washer head blade Screws 4 WARNING To reduce the risk of fire electric shock or personal injury mount fan to outlet box marked Acceptable for Fan Support and use screws supplied with outlet box Most putlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electric
6. box marked Acceptable for Fan Support and use screws supplied with outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt AA AVERTISSEMENT Pour r duire le risque d incendie de choc lectrique ou de blessures ne montez le ventilateur que dans un boitier de prises de courant comportant les termes Acceptable pour le raccordement d un ventilateur et utilisez les vis fournies avec le boitier La plupart des boitlers de prises de courant utilis s couramment pour le raccordement de luminalres ne sont pas acceptables pour le raccordement de ventilateurs et devront peut tre tre remplac s Consultez un lectriclen professionnel en cas de doute If your fan is to replace an existing ceiling light fixture turn electr city off at the main fuse box at this time and remove the existing light fixture AA WARNING Turning off wall switch is not sufficient To avoid possible electrical shock be sure electricity is turned off at the main fuse box before wiring All wiring must be In accordance with National and Local codes and the ceiling fan must be properly grounded as a precaution agalnst possible electrical shock A AVERTISSEMENT li n est pas suffisant de couper l alimentation au niveau du commutateur mural Pour viter tout risque de choc lectrique assurez vous que l lectricit est coup
7. d SUPPLY NOTE CEIL the supply wires througn the open side of the hanger bracket ELA BLACK FAN WIRE NOI ITED FOR CLARITY Position the Receiver in the celling cover so that the flat side of in the recelver faces up and the open portlon of the receiver is to WHITE SUPPLY the right as shown CONR LR 77 NEUTRAL Using wire connectors supplied make wiring connections as follows Connect the green ground wires from the hanger bracket GREEN WIRE i GROUND FROM m hanger ball to the supply ground wire bare or AEN D ROM GREEN WIRE BLACK SUPPLY HOT i GROUND FROM Connect the white fan to the white supply wire rite ERN A Connect the black fan wire to the black supply wire SEDE Installation of Ceiling Cover paye 12 After connections have been made turn leads upward and carefully push leads Into the outlet box with the white and f 1 CEILING COVER green leads on one side of the outlet box and the black blue and yellow leads on the other side of the outlet box Lift the ceiling cover up to the threaded studs and turn until studs protrude through the holes in the ceiling cover Secure the ceiling cover In place by sliding lock THREADED STUD washers over the threaded studs and installing the two knurled knobs supplied Tighten the knurled knobs securely until the celling cover fits snugly against the ceiling Your fan is now KNURLED KNOB wired to be controlled using the remote control tra
8. evis pin from working loose Pull on the downrod to make sure the clevis pin is properly installed AA WARNING It Is critical that the clevis pin in the motor coupling Is properly installed and the setscrew securely tightened Failure to verify that the pin and setscrew are properly installed as shown in Figure 2 could resutt in the fan falling A AVERTISSEMENT Il est crucial que l axe d assemblage dans l accouplement du moteur soit install correctement et que la vis de blocage soit bien serr e SI vous ne vous assurez pas que l axe et la vis sont install s correctement comme cela est illustr la Figure 2 le ventilateur risquerait de tomber 3 While pulling up on the downrod securely tighten the setscrew in the motor coupling Figure 3 NOTE The setscrew must be properly installed as described above or fan wobble could result 4 Remove the three screws pre installed on top of the fan assembly and retain for use in Step 6 Make sure the grommet is properly installed in the coupling cover then slide the coupler cover on the downrod until it rests on the motor housing Place the ceiling cover over the downrod Be sure both the ceiling cover and the coupler cover are oriented correctly Figure 3 Reinstall the three screws removed In Step 4 through the coupler cover and into the fan assembly HANGER BALL A SETSCREW Figure 1 DOWNROD HAIRPIN CLIP SETSCREW MOTOR COUPLING Figure 2 S
9. ian if tn doubt Installation of Ceiling Fan page 8 1 Remove the three screws pre installed on top of the fan assembly Install the coupler cover and ceiling cover onto the downrod Reinstall the three screws through ihe coupler cover Relnstall the hanger ball onto the downrod place the pin into the hanger ball and tighten the setscrew Remove two of the four screws In the motor assembly and loosen the remaining two Screws Connect the terminals of the lower housing assembly to the terminals of the fan motor assembly Hanging Your Ceiling Fan page 10 circuit breaker or fuse box before attempting to install ATLEAST the ceillng fan hanger bracket on the outlet box M 4 WARNING Turning oft wall switch is not sufficient To avoid possible electrical shock be sure electricity is turned off at the main fuse or circult breaker box before wiring All wiring musi ba in accordance with Natlonal and Local codes and the ceiling fan must be properly grounded as a precaution against possible electrical shock Disconnect electrical power to CEILING the branch circuit at the n e 2 The fan must be hung with at least 7 of clearance from floor to blades 3 Attach the hanger bracket to the outlet box 4 Seat the hanger ball downrod assembly on the hanger bracket EMERSON QUICK START GUIDE Wiring Ceiling Fan page 11 Pull the wire leads coming from the end of the downrod an
10. k Electrical installation should be made or approved by a licensed electrician The outlet box and Jolst must be securely mounted and capable of reliably supporting at least 50 pounds Use only U L outlet boxes listed as Acceptable for Fan Support and use the mounting screws provided with the outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt The downrod furnished with the fan proves the minimum recommended floor to fan blade clearance for an 8 foot ceiling The fan must be mounted with the fan blades at least 7 feet from the floor to prevent accidental contact with the fan blades Follow the recommended instructions for the proper method of wiring your ceiling fan If you do not know enough about electrical wiring have your fan installed by a licensed electrician NOTE This fan is suitable for use with solid state speed controls WARNING To reduce the risk of flre or electrical shock this fan should only be used with fan speed control Model No FR 7861LMA manufactured by Rhine Electric Co Ltd AVERTISSEMENT pour r duire le risque d incendie ou de choc lectrique ce ventilateur ne doit tre utilis qu avec la commande de r glage de la vitesse du ventllateur Mod le N FR 7861LMA fabriqu e par Rhine Electric Co Ltd WARNING This product is designed to use only those parts supplied
11. nce have your fan installed by a licensed Wiring outlet box and box connectors must be of type electrician required by the local code The minimum wire would be a 3 conductor 2 wire with ground of the following AA AVERTISSEMENT U AVERTISSEMENT Wire Size AWG Up to 50 ft 14 50 100 ft 12 Avant d effectuer le montage de votre ventilateur de plafond r f rez vous la section consacr e la m thode de c blage appropri e pour votre ventilateur page 8 Si vous pensez que vous n avez pas assez de connaissances ou d exp rience en mati re de connexions lectriques demandez un lectricien professionnel d installer votre ventilateur Unpacking Instructions 1 Check to see that you have received the followin Do not Install or use fan if any part Is damaged or NOTE If you are uncertain of part description missing A AVERTISSEMENT li ne faut pas installer ou utiliser ce ventilateur si l un quelconque de ses l ments est endommag ou manquant This product is designed to use only those parts supplied with thls product and or any accessories designated specifically for use with this product by Emerson Electric Co Substitution of parts or accessories not designated for use with this product by Emerson Electric Co could result in personal injury or property damage refer to exploded view illustration Fan motor assembly One lower housing assembly One ceiling cover Five
12. nsmitter The receiver must be programmed within 2 minutes of restoring electricity to the fan Program the receiver code by pushing and holding down the remote control OFF button for 3 5 seconds The ceillng fan lights will blink when the receiver has completed programming If programming fails shut off and turn on the electricity at the wall switch to reset the receiver Repeat Step 1 above If programming continues to fail change the remote code and repeat Steps 1 and 2 as necessary until the fan successfully completes the programming procedure NOTE Fan installation must be completed including the installation of the fan blades before testing the remote control 4 Your SR600 Fan Light remote control has full control of your fan speed alr flow direction and light intensity NOTE The following procedure must be completed 8 Operate the fan at high speed for 2 minutes Reverse the fan and operate on high speed 2 additional minutes Far additional installation review full instructions on page 13 This Manual Is Designed to Make it as Easy as Possible for You to Assemble Install Operate and Maintain Your Ceiling Fan Tools Needed for Assembly One Phillips head screwdriver One stepladder Before assembly your ceiling fan refer to section on One 1 4 blade screwdriver One wire stripper proper method of wiring your fan page 11 lf you feel you do not have enough wiring knowledge or MATERIALS experie
13. s of assembly Your Emerson ceiling fan comes supplied with a Fan Light Remote Control which consists of a receiver mounted inside the ceiling cover of the fan motor housing This system allows you to regulate your ceiling fan speed and light ON OFF i COUPLER COVER f HANGER BRACKET e HANGER BALL DOWNROD ASSEMBLY c CEILING COVER g GLASS BOWL a FAN ASSEMBLY 2 89 1 9 13W GU 24 f LOOSE FLOURESCENT e 9 LAMPS we b LOWER C LAC We 0086 ASSEMBLY h FAN LIGHT CONTROL How to Put Your Ceiling Fan Together 1 Remove the hanger ball by loosening the setscrew in the hanger ball until the ball falls freely down the downrod Figure 1 Remove the clevis pin from the downrod then remove the hanger ball Retain the pin and hanger ball for reinstallation in Step 5 Loosen setscrew in motor coupling if necessary Separate untwist and unkink the black and white 80 motor leads Route the motor lead wires through the downrod Align the clevis pin holes In the downrod with the holes in the motor coupling install the clevis pin and secure with the hairpin clip Figure 2 The clevis pin must go through the holes in the motor coupling and the holes in the downrod Be sure to push the straight leg of the hairpin clip through the hole near the end of the clevis pin until the curved portion of the hairpin clip snaps around the clevis pin The hairpin clip must be properly installed to prevent the cl
14. sembly make sure the a ABEL label on the blades are facing the bottom of the OTTOM OF BLADE ceiling fan Slide blade through center slot in fan housing Mount blades to fan housing using three 3 16 24 x 1 2 slotted Phillips washer head blade screws on each blade Figure 5 ASSEMBLY NOTE Take care not to scratch fan housing when TERMINALS installing blades FAN MOTOR 11 Remove two of the four screws in the motor ASSEMBLY assembly and loosen the remaining two screws Figure 6 12 Connect the terminals of the lower housing assembly to the terminals of the fan motor BUS M nen assembly Figure 6 2 SCREWS Figure 6 How to Put Your Ceiling Fan Together continued 13 Attach the lower housing assembly to the fan motor using the two key slot holes Figure 7 Secure the lower housing assembly by tightening the two screws Reinstall and tighten the two screws that were removed NOTE Make sure wires and terminals are positioned in raised center area of lower housing assembly and not pinched between fan and light kit LOWER HOUSING ASSEMBLY SCREWS 2 Li Aer A HOLE 2 Electrical Requirements Your new ceiling fan will require a grounded electrical supply line of 120 volts AC 60 Hz 15 amp circuit The outlet box must be securely anchored and capable of withstanding a load of at least 50 pounds AA WARNING To reduce the risk of fire electric shock or personal injury mount fan to outlet
15. wlth this product and or any accessories designated specifically for use this product by Emerson Electric Co Substitution of parts or accessories not designated for use with this product by Emerson could result in personal injury or property damage AVERTISSEMENT ce produit est concu pour un emploi exclusif avec les pi ces fournies avec ce produit et ou avec des accessoires d sign s sp cifiquement pour emploi avec ce produit par Emerson Electric Co La substitution de pi ces ou d accessoires n ayant pas t d sign s pour emploi avec ce prodult par Emerson pourrait causer des blessures ou des dommages mat rieis WARNING To reduce the risk of personal injury do not bend the blade flange when installing the blade flanges balancing the blades or cleaning the fan Do not insert foreign objects in between rotating fan blades AVERTISSEMENT pour r duire le risque de blessures ne courbez pas la collerette de pale lors de l installation ou lorsque vous quilibrez les pales ou nettoyez le ventilateur N ins rez pas d objets trangers entre les pales du ventilateur en mouvement WARNING To reduce the risk of electrical shock thls fan must be installed with a general use isolating control switch AVERTISSEMENT pour r duire le risque de choc lectrique il faut Installer ce ventilateur avec un interrupteur coupe clrcuit isolant universel DATE CODE The date code of this fan may be found on the box stamped in ink on a white label