Sea Gull Lighting 49180BLE-98 Installation Guide

image

Contents

1. PLATE SOCKET PIPE B FIBER WASHER M F A m s DIFFUSER N DECORATIVE CAP NUT H FIG 1 NOT SUPPLIED ITEM Fill in item number located on carton and file this sheet for future reference HC 242 101800 INSTALLATION HC 242 IMPORTANT DO NOT ATTACH FIXTURE DIRECTLY TO OUTLET BOX IF SUPPLY WIRES ARE LOCATED WITHIN 3 OF BALLAST USE WIRE RATED FOR AT LEAST 90 C STEP 1 Insert fixture mounting screws I in threaded holes of universal mounting bar J Run screws all the way down to the heads STEP 2 Place universal mounting bar J against outlet box not suppplied and screw in place using outlet box screws not supplied Be sure the mounting screws are perfectly horizontal so fixture hangs straight STEP 3 A Take note of the color of the wire s on your fixture Identify which group your fixture wire s falls into and connect the wires according to the directions below t GROUP A CONNECT TO BLACK GROUP B CONNECT TO WHITE HOUSE WIRE HOUSE WIRE BLACK WHITE oN l PARALLEL WIRE ROUND amp SMOOTH f PARALLEL WIRE SQUARE amp RIDGED y WHITE OR GREY WITH TRACER r TATE TS BROWN GOLD OR BLACK WITHOUT TRACER WHITE OR GREY WITHOUT TRACER BROWN GOLD OR BLACK WITH TRACER NOTE When parallel wire is used the tracer wire is square shaped or ridged and the less tracer wire is round in shape or smooth Seen best when viewed from wire end To sepa
2. INSTALLATION AND SAFETY INSTRUCTIONS FOR YOUR SAFETY WARNING BE SURE THE ELECTRICITY TO THE WIRES YOU ARE WORKING ON IS SHUT OFF EITHER THE FUSE REMOVED OR THE CIRCUIT BREAKER OFF GENERAL You don t need special tools to install this fixture Be sure to follow the steps in the order given Under no circumstances should a fixture be hung on house electrical wires nor should a swag type fixture be installed on a ceiling which contains a radiant type heating system Read instructions carefully If you are unclear as to how to proceed consult a qualified electrician NOTE Proper wiring is essential for the safe operation of this fixture OUTLET BOX UNIVERSAL MOUNTING PLATE J WIRE CONNECTOR CAP NUT G _ SHORT NIPPLE E GROUNDING amp UNIVERSAL MOUNTING BAR LOCK UP FIG 2 GREEN GROUNDING SCREW L OUTLET BOX SCREWS OUTLET BOX MOUNTING SCREWS I WIRE CONNECTOR UNIVERSAL MOUNTING PLATE J FIG 2 NOT SUPPLIED ASSEMBLY STEP 1 Carefully remove the fixture from the carton and check that all parts are included as shown in Figure 1 amp 2 Be careful not to misplace any of the screws or parts which are needed to install this fixture STEP 2 Snap sockets A to faceplate F if applicable Insert short threaded side of pipe B thru front plate F as shown in Fig 1 Place lock washer C on pipe B amp secure in place with nut D if applicable FACE
3. rate wires grasp the ends of each wire and pull apart B Take your fixture wire s from group A and place evenly against the black wire from the outlet box Do Not twist wires together before using wire connectors C Fit a wire connector not supplied over the wires and screw the connector clockwise until you feel a firmness D Try gently to pull the connector off the wires If you can pull the connector off carefully re do steps B and C as above and check again for a firm connection E Connect the fixture wire from group B to the white wire from the outlet box in the same manner STEP 4 GROUNDING INSTRUCTIONS The green grounding screw L is to be inserted into the hole with two raised dimples provided on the universal mounting bar J Wrap the ground wire from the fixture if supplied and the ground wire from the outlet box bare metal or green insulated wire around the green grounding screw L on the universal mounting bar J If uninsulated ground wire is on the universal mounting bar connect the ground wire from the fixture if supplied and the outlet box to it using a small wire connector not supplied See Figure 2 NOTE Underwriters Laboratories does not require all fixtures to have ground wires These fixtures still meet all U L specifications NEVER CONNECT GROUND WIRE TO BLACK OR WHITE POWER SUPPLY WIRES FINAL ASSEMBLY Make sure no bare wires can be seen outside wire connectors STEP 1 After
4. wires are connected tuck them carefully inside the outlet box Position backplate F over mounting screws I and secure in place with cap nut G STEP 2 Insert short nipple E into diffuser N as shown in Fig 1 amp secure with decorative cap nut H if applicable STEP 3 Install lamps STEP 4 Install fiber washer M and diffuser N in that order onto pipe B Secure with decorative cap nut H CLEANING To clean wipe fixture with a soft cloth Clean glass with a mild soap Do not use abrasive materials such as scouring pads or powders steel wool or abrasive paper ORDERING PARTS Keep this sheet for future reference and in case you need to order replacement parts All parts for this fixture can be ordered from place of purchase Be sure to use exact wording from illustration when ordering parts

Download Pdf Manuals

image

Related Search

Related Contents

  Service Manual 2  Dale Tiffany FTT10004 Instructions / Assembly  DECRETO NÚMERO 1996 - Parques Nacionales de Colombia  Approx 16GB USB 2.0 Flash Memory Key    Samsung HT-C7559W Užívateľská príručka  JVC KV-V8 Supplementary Manual  DE Bedienungsanleitung Der Laborgasbrenner für mehr    

Copyright © All rights reserved.
Failed to retrieve file