Home
Pelican Water PUV-16-Lamp Instructions / Assembly
Contents
1. E C i ae L E g TROJAN UVMAX Lamp amp Sleeve Replacement Electrical hazard Be sure to unplug power supply Keep all electrical connections dry and off the ground Do not touch plug with wet hands A This product is for indoor use only Keep all components clean and dry Never look at the lamp when it is operating A Always shut off water flow and release water pressure before servicing NA Read directions before servicing Sleeve cleaning Minerals in the water slowly form a coating on the sleeve This coating must be removed because it reduces the amount of UV light reaching the water thereby reducing purification performance Basic models please clean the sleeve regulary 3 4 times per year or more often depending on water quality Plus models the need to clean the sleeve will be indicated by a low UV alarm see Owner s manual for details When only cleaning is required follow instructions and re install the current lamp Lamp replacement The amount of UV light created by the lamp decreases over time requiring that the lamp be replaced every 12 months NOTE The UV system is designed to operate continuously and should not be shut off for short periods of time such as over a period of less than three weeks A B C B4 C4 Models Please keep track of your lamp s life After 12 months follow these instructions to replace system with a new lamp D E F D4 E4 F4 and Plus Models The system will
2. automatically notify you after 12 months to replace the lamp Follow these instructions Equipment required y Clean cotton Scale remover Cloth must be Cottom swab latex or plastic such as CLR or soft lint free and gloves are Lime Away chemical free No preferred clean wipes VIQUA a Trojan Technologies Company 425 Clair Road West Guelph ON Canada N1L 1R1 August 2010 www viqua com info viqua com 1 800 265 7246 North America 519 763 1032 602808 revL devices such as junction boxes and remote alarms If you have a black power supply with a sensor unplug sensor from blue Jack Let the system cool for 10 minutes Note System figures may look slightly different than your actual system Remove Safety cap Pull the lamp plug off the lamp end do not pull by lamp plug s cable Hold by sleeve bolt to remove lamp sleeve assembly For sleeve cleaning only g Y Skip to step 15 Note Sleeve must be replaced if it cannot be completely cleaned or if it appears scratched or cracked For lamp or sleeve replacement Follow steps 11 14 Clean outside of sleeve if only replacing lamp Hold sleeve bolt with one hand Use other hand to unscrew lamp from sleeve bolt by holding lamp tab Remove o rings and sleeve bolt from sleeve Reinstall sleeve bolt with 2 new o rings Screw into sleeve bolt hand tight Caution Over tightening will break the sleeve Make sure lamp sl
3. eeve assembly is centered Caution Over tightening will break the sleeve For Basic models skip to step 19 63 Check for leaks If lamp was not replaced or you have model A B C B4 or C4 Plug in power supply and skip gt to Step 31 Press and hold the push button If lamp was replaced Restart lamp timer D E F D4 E4 F4 and Plus models only Follow steps 26 amp 27 if you have a black power supply Follow steps 28 30 if you have a blue power supply for 5 seconds Display should read 365 1 5 k fa a ek _ ri a ey er oa k J q A o k nmh F i b T i i j SS i LN Skip to Step 31 Continue pressing the push button while plugging in the power supply Indicator light will flash green Indicator light Push button e When the indicator light flashes red release the push button Display should now read 00 If timer does not read 00 unplug power supply wait 15 seconds and then repeat steps 28 30 Plug in all peripheral devices such as junction boxes and remote alarms Disinfect the water lines UV systems purify the water using ultraviolet light treating the water as it passes through the system When there is a risk that water downstream of the UV system has been contaminated it is critical that these water lines be chemically disinfected Let the bleach sit in the water lines for Flush all water outlets unt
4. il bleach at least four hours can no longer be smelled at least 5 minutes E oe Pai Se 42 T Allow water to fill UV Remainder of steps chamber f for models D4 Plus k E4 Plus F4 Plus ae Go to a water outlet and allow the 61 Plug sensor into blue jack cold water to flow until you can smell bleach then stop the flow Allow hot water if present to flow until you can smell bleach then stop the flow Repeat procedure at all water outlets Remember to include all faucets washing machines toilets outside taps and other water outlets Note You will likely run out of bleach if you cannot smell bleach at a given outlet turn off the main water supply depressurize and add more bleach to the filter housing
Download Pdf Manuals
Related Search
Related Contents
QuadScan Elite User`s Manual データシート 余剰含油率計測 Cooler Master R9-NBC-NPP2-GP notebook cooling pad DDJ-SB - Pioneer DJ Manuale d'uso User Manual Betriebs und Wartungsanleitung Samsung MD230X3 用户手册 Three claw fish light Le cahier de brevets et de réussites : mode d`emploi Le cahier de Copyright © All rights reserved.
Failed to retrieve file