Home
Salsbury Industries 19055-10GRK Instructions / Assembly
Contents
1. Installation of Identification Window Identification labels clear plastic windows and metal window backup plates are provided separately bagged for use in marking the user s identity on each locker door The steps below are numbered according to the picture to the right 1 Mark the user s name or other appropriate identity on one of the 1 2 x 2 labels provided Tear the label from the card 2 Insert the label into the clear plastic window so that the marking will be visible from the front of the locker door 3 Place the clear plastic window into the rectangular hole in the door so that the identity is visible from the front of the door 4 Slide metal window backup plate down into grooves at top of door Slide plate down until it covers the plastic window and the bent lip of the plate rests on the top edge of the plastic window REAR VIEW SALSBURY INDUSTRIES 1010 East 62 Street Los Angeles CA 90001 1598 Phone 1 800 624 5269 Int l Phone 323 846 6700 Fax 1 800 624 5299 Int l Fax 323 846 6800 Installation instructions are provided as general guidelines It is advised that a professional installer be consulted Salsbury Industries assumes no product assembly or installation liability Copyright 2013 Salsbury Industries All rights reserved Rev 10 6 4 2013 Page 5 of 6 Cell Phone Lockers 19000 Series Resettable Combination Loc
2. Street Los Angeles CA 90001 1598 Phone 1 800 624 5269 Fax 1 800 624 5299 Intl Phone 323 846 6700 Int l Fax 323 846 6800 Installation instructions are provided as general guidelines It is advised that a professional installer be consulted Salsbury Industries assumes no product assembly or installation liability Copyright 2013 Salsbury Industries All rights reserved Rev 10 6 4 2013 Page 2 of 6 Cell Phone Lockers 19000 Series Recessed Mounted Installation Instructions Overall Dimensions and Rough Opening Dimensions Overall Dimensions 8 Deep Compartments 7 Doors High Width Height 19078 14 2 A Doors Wide 16 1 4 40 31 9 19078 21 3 A Doors Wide 22 3 4 40 31 9 19078 24 4 A Doors Wide 29 1 4 40 31 9 19078 35 5 A Doors Wide 35 3 4 40 3 4 9 6DoorsHigh 19068 10 2 A Doors Wide 16 1 4 35 11 9 19068 18 3 A Doors Wide 22 3 4 35 11 9 19068 20 4 A Doors Wide 29 1 4 35 11 9 19068 30 5 A Doors Wide 35 3 4 35 114 9 5DoorsHigh 19058 09 2 A Doors Wide 16 1 4 29 31 9 19058 10 2 B Doors Wide 29 1 4 29 31 9 19058 15 3 A Doors Wide 2 3 4 29 31 9 19058 16 4 A Doors Wide 29 1 4 29 31 9 4 o 5 La 2 o 3 LF ae 5 Le E Co 3 Oo ae Lor 4DoorsHigh 3DoorsHigh 36 3 4 18 314 Calculation of Overall Dim
3. 1598 Phone 1 800 624 5269 Fax 1 800 624 5299 Intl Phone 323 846 6700 Int l Fax 323 846 6800 Installation instructions are provided as general guidelines It is advised that a professional installer be consulted Salsbury Industries assumes no product assembly or installation liability Copyright 2013 Salsbury Industries All rights reserved Rev 10 6 4 2013 Page 3 of 6 Cell Phone Lockers 19000 Series Recessed Mounted Installation Instructions Top View of Cell Phone Lockers in Wall OVERALL WIDTH ROUGH OPENING CABINET WIDTH ROUGH OPENING 8 DEEP LOCKERS 5 DEEP LOCKERS CABINET OVERALL TRIM WIDTH O 1 X 6 SECURE BOTH 2 X 6 ENDS TO 2 X 6 FRAME FRAME OVERALL TRIM WIDTH OF CABINETS Side View of Cell Phone Lockers in Wall 8 DEEP LOCKERS 5 DEEP LOCKERS N E T UN lt L gt lt SALSBURY INDUSTRIES 1010 East 62 Street Los Angeles CA 90001 1598 Phone 1 800 624 5269 Int l Phone 323 846 6700 Fax 1 800 624 5299 Int l Fax 323 846 6800 Installation instructions are provided as general guidelines It is advised that a professional installer be consulted Salsbury Industries assumes no product assembly or installation liability Copyright 2013 Salsbury Industries All rights reserved Rev 10 6 4 2013 Page 4 of 6 Cell Phone Lockers 19000 Series identification Window Installation Instructions
4. provided as general guidelines It is advised that a professional installer be consulted Salsbury Industries assumes no product assembly or installation liability Copyright 2013 Salsbury Industries All rights reserved Rev 10 6 4 2013 Page 6 of 6
5. 46 6800 Installation instructions are provided as general guidelines It is advised that a professional installer be consulted Salsbury Industries assumes no product assembly or installation liability Copyright 2013 Salsbury Industries All rights reserved Rev 10 6 4 2013 Page 1 of 6 Cell Phone Lockers 19000 Series Recessed Mounted Installation Instructions The recessed mounted cell phone locker must be securely supported by a frame constructed of 2 x4 or 2 x6 lumber Construct support framing as shown on page 4 of these instructions Cut a hole in the wall according to the Rough Opening Dimensions calculated on page 3 Installation Instructions Place the unit in the rough opening Open all left hand compartment doors Locate a screw in each compartment fastened into the left vertical door frame member some compartments may not have a screw Remove screws REMOVE SCREW IN EACH LEFT SIDE COMPARTMENT Open the master door and drill mounting holes through the sides of the peripheral flange of the locker unit Fasten the unit hardware not provided to the support framing Close the master door and re install the removed screws DRILL MOUNTING HOLES AND INSTALL FASTENERS THROUGH SIDE FLANGES Notes 1 Wall opening and lumber frame must be square 2 Do not deform force or twist the locker frame to fit an incorrect rough opening or fit against an irregular surface SALSBURY INDUSTRIES 1010 East 62
6. Cell Phone Lockers 19000 Series Surface Mounted Installation Instructions The surface mounted cell phone locker may be installed on the surface of a wall on a table or a counter top It is the installer s responsibility to ensure the unit is properly anchored to prevent tearing out of a wall or tipping over on a table or counter top Installation of the Surface Mounted Enclosure Remove the locker unit from the enclosure Drill mounting holes in the enclosure to fasten it to the mounting surface Itis important to use at least four 4 fasteners not provided and place one each at the four 4 corners of the mounting surface either on the rear panel or the bottom panel Choose appropriate hardware for the particular conditions of the installation 4 SCREWS IN CORNERS OF REAR PANEL OR 4 SCREWS IN CORNERS OF BOTTOM PANEL Installing the Cell Phone Locker into the Enclosure Install the locker unit into the enclosure by sliding it into the enclosure until its front peripheral flange is flush against the front of the enclosure Open the four corner compartments of the cell phone locker Install 8 x 1 1 4 in long screws provided through the top and bottom of the locker unit into the enclosure Close the compartment doors OPEN CORNER COMPARTMENTS TO FASTEN TO ENCLOSURE SALSBURY INDUSTRIES 1010 East 62 Street Los Angeles CA 90001 1598 Phone 1 800 624 5269 Fax 1 800 624 5299 Intl Phone 323 846 6700 Int l Fax 323 8
7. ensions of Multiple Units Width and height of outside trim frame of each unit Overall Width No of doors wide times 6 1 2 plus 3 1 4 Note B door count as 2 A doors wide Overall Height No of doors high times 5 1 2 plus 2 1 4 Overall Dimensions 5 Deep Compartments 7 Doors High Width Height 19075 14 2 A Doors Wide 16 14 40 31 19075 21 3A Doors Wide 22 3 4 40 3 4 19075 24 4 A Doors Wide 29 1 4 40 31 19075 35 5 A Doors Wide 35 3 4 40 3 4 6DoorsHigh 19065 10 2 A Doors Wide 16 1 4 35 11 19065 18 3 A Doors Wide 22 3 4 35 11 19065 20 4 A Doors Wide 29 114 35 1 4 19065 30 5 A Doors Wide 35 3 4 35 1 4 5DoorsHigh 19055 09 2 A Doors Wide 16 1 4 29 31 19055 10 2 B Doors Wide 29 1 4 29 3 4 19055 15 3 A Doors Wide 22 3 4 29 3 4 19055 16 4 A Doors Wide 29 1 4 29 31 4 Le 5 MEA 2 O 3 O Poo 5 O E 3 or eae Lee 4DoorsHigh 3DoorsHigh 36 3 4 18 314 Calculation of Rough Opening Dimensions Width of Rough Opening Overall Width less 1 For multiple units Sum of Overall Widths less 1 Height of Rough Opening Overall Height less 1 SALSBURY INDUSTRIES 1010 East 62 Street Los Angeles CA 90001
8. ix The lock is now set to continuously open using the custom fixed combination After locking scrambling the four 4 dials will secure the contents Setup for a Resettable Combination 1 If locked turn the four 4 dials to the factory preset combination 0000 or the known combination that unlocks the lock 2 Turn the operation knob clockwise 180 to the open position The indicator in the window will turn from red to green 3 Turn the reset fix stem on the back of the lock from the Fix to the Reset position Leave the button in this position 4 Close the door Do not lock it The lock combination can now be resettable by the user setting their own desired combination before turning the operation knob to the locked position red window indicator After locking scrambling the four 4 dials will secure the contents DECODE SEVER PUSH RESETFIX STEM Decode Operation Used to determine lock combination 1 Open the door Use the master key if necessary 2 Push the decode lever up and hold it in place Rotate each of the dials on the front of the lock until it stops or there is a click sound Release the decode lever 3 Each dial will now be in the open combination position SALSBURY INDUSTRIES 1010 East 62 Street Los Angeles CA 90001 1598 Phone 1 800 624 5269 Fax 1 800 624 5299 Int l Phone 323 846 6700 Int l Fax 323 846 6800 Installation instructions are
9. k Operating amp Resetting Instructions The resettable combination lock is a durable and easy to use lock providing resettable combination access without the need for keys Please read this entire page before use RED GREEN OPERATION INDICATOR KNOB FOUR 4 WINDOW DIALS The lock has a four 4 digit combination setting When the lock is locked closed a red indicator appears in a window next to the operation knob When the lock is unlocked open a green indicator appears in the window There are two 2 modes of operation fixed combination or resettable combination In fixed combination mode the lock is continually opened and closed with the same custom combination that was set In the resettable combination mode the combination may be changed after each time the lock is opened The factory preset combination is 0000 Master key operation may be used at any time to open a lock Setup for a Fixed Combination 1 If locked turn the four 4 dials to the factory preset combination 0000 or the known combination that unlocks the lock 2 Turn the operation knob clockwise 180 to the open position The indicator in the window will turn from red to green 3 Turn the reset fix stem on the back of the lock from the Fix to the Reset position 4 Returning to the front of the lock set the desired custom fixed combination on the four 4 dials 5 On the back of the lock return the reset fix button back to F
Download Pdf Manuals
Related Search
Related Contents
SIVACON S8 Installation and Operating Instructions Samsung Galaxy Gio Käyttöopas(Gingerbread) Samsung SGH-D848 User Manual RotoLift Stretch Wrapper Operators Manual C.C.329 ® Bedienungsanleitung 4 - 9 Torsteuerung S 60 II + Multicard II GB AVRDude Userguide Copyright © All rights reserved.
Failed to retrieve file