1. 060638A 060638SS Vandal Resistant Laminar Outlet with Anitmicrobial by AglONTM 060640A 060640SS Vandal Resistant Flow Control Aerator and Wrench 060642A 060642SS Flow Control Aerator RP31704 RP31704SS Spray Outlet with Wrench 0 5 GPM Vandal Resistant 060566A 060566SS Optional Spray Outlet with Wrench 1 0 GPM Vandal Resistant 060930A Battery Box Assembly less driver board and battery holder 060905A Cover Gasket 060906A Surface Mount Housing 060907A Driver Board 060690A 36 Cable Extension RP30523 Braided Hose 060416A Bypass Adaptor 060683A 24VAC to 6VDC Converter 060953A 060953SS Spout Assembly RP6420 Wrench NS 2 RP6001 ye O S Nut 8 Washer D l 060416A Bypass Adapter Braided Hose 060910A Solenoid Valve with 3 8 Compression Connectors 060913A 3 8 x 3 8 Compression Connector Nut and Ferrule 591T __2__ O Parts for Base Model with Wall mount Box See page 3 for Recess Mount Box Parts NOTE For optimum performance of this product we recommend a system pressure between 20 and 80 PSI static This product will operate up to a maximum of 125 PSI static per ANSI and CSA requirements However we do not recommend pressure above 80 PSI Thermal expansion or leaking pressure reducing valves may require use of expansion tanks or relief valves to ensure
2. 4L6 Box 40980 55 East 111th St Indianapolis Indiana USA 46280 1 800 567 3300 English 1 800 265 9245 French 317 848 1812 For further technical assistance call Delta Commercial Technical Service at 1 800 387 8277 www deltafaucet com spec S el ec t www specselect com com TECK Page 7 203910 Rev A
3. Connect the battery snap of the hardwire converter to the driver board battery clip Turn on power supply for the transformer and then make the sensor connection on the control module neatly inside the battery box STEP 6 PREPARE SINK AREA Before connecting the spout cable clean off counter and remove all objects from the sink STEP 7 TIE SPOUT CABLE Attach spout cable to box connector Use tie wraps to secure spout cable to spout hose Your faucet is now ready for use Fig 2 STEP 8 TEST FOR OPERATION Test for operation If faucet leaks from spout outlet SHUT OFF WATER SUPPLIES Replace Battery Box Assembly 1 If faucet exhibits very low flow A Remove and clean Spray Outlet or B SHUT OFF WATER SUPPLY Clean or replace Screen Assembly 2 If unit does not work properly see Trouble Shooting Guide on Page 5 TECK Page 2 13 331 mm Max 7 178 mm Max Tie Wraps NOTE Entire connection can be placed inside battery box if desired Fig 2 Bypass Adapter Teflon Tape Fig 3 NOTE Always make sure driver board is in place before inserting the battery pack Use caution not to pinch wires or damage components on the electronic driver board Trap jacket of cable in hole for strain relief Fig 5 203910 Rev A Installation should be in accordance with local plumbing and electrical codes FLUS
4. E VERSION Install CSA and or UL approved Class 2 transformer or equivalent in a convenient location or in a pipe chase Do NOT install the transformer inside the control box With the power off bring the 24 VAC supply wires into the box Connect the 24 VAC supply to the 060683A conversion kit Connect the battery snap of the hardwire converter to the driver board battery clip Turn on power supply for the transformer and then make the sensor connection on the driver board neatly inside the box Secure cover using screws a 102mm 4 TECK Page 4 Product supplied as shown by solid lines All items shown by dotted lines supplied by others Valve Spacer Replace with SOLENOID Valve after system is flushed Solenoid Valve INSTALL replacing SPACER after system is flushed SOLENOID J Y may be ROTATED to gt ALLOW for installation of COVER ASSEMBLY Fig 12 203910 Rev a INSTALLATION AND SET UP INSTRUCTIONS FOR RECESS MOUNT HOUSING CONTROL BOXES 1 6 8 STEP 6 SERVICES Open screwdriver stop s Flush line Install aerator STEP 7 TEST FOR OPERATION Test for operation If unit does not work properly see Trouble Shooting Guide on page 6 STEP 8 MAKING ADJUSTMENTS If adjustments are required Note factory defaults for program shown in Quick Reference Chart Otherwise replace the driver board
5. Fig 2 STEP 3 FLUSH SYSTEM To flush supply line assemble these components as shown Fig 3 and run water for 1 minute Shut off water supply Attach aerator NOTE Do not connect supply to the solenoid inlet until line is flushed directly out spout STEP 4 CONNECT WATER SUPPLY Disassemble the components reassemble the ones shown here Fig 4 supply line and adaptor to the bottom fitting on box braided hose to the top fitting on box Use Teflon tape where indicated on adaptor Turn on water supply DO NOT SOLDER CONNECTIONS STEP 5 POWER UP Unscrew the battery box lid screws 2 Install four C batteries in holder or snap the battery clip directly to the optional 24 VAC converter BATTERY VERSION Install four C batteries provided into the battery box After the batteries are installed make the sensor connection on the driver board neatly inside the battery box Connect battery clip to battery pack One beep should occur to indicate power is applied Two beeps indicate product is ready to use Use caution not to damage wires or components on electronic driver board See Fig 5 Secure lid using screws HARDWIRE VERSION Install CSA and or UL approved Class 2 transformer or equivalent in a convenient location or in a pipe chase Do NOT install the transformer inside the control box With the power off bring the 24 VAC supply wires to the box Connect the 24 VAC supply to the 060683A conversion kit See Page 1
6. H ALL PIPES THOROUGHLY BEFORE INSTALLATION INSTALLATION AND SET UP INSTRUCTIONS FOR RECESS MOUNT HOUSING CONTROL BOXES 1 6 8 STEP 1 ROUGH IN HARDWIRE Remove suitable knockout s in box es and insert cable bushing s See Fig 6 Cable Bushing Note Wires connecting between box es and from transformer must be protected from abrasion and being pulled at connections They also may have to be fished through at a later stage of construction Depending on installation the cable bushings included may be replaced by installer supplied 1 2 conduit Rough in box as per Fig 10 The transformer is to be installed in an adjacent accessible space Do NOT install the transformer inside the control box Cable from the transformer to the driver board may be roughed in at this time depending on installation Use cable which complies to local electrical Knockouts codes for a 1 amp load No 18 is usually sufficient HARDWIRE OR BATTERY lf recessed box is supplied rough in as per Fig 10 The most vandal resistant installation is when the control box is as close to the bottom of the sink as feasible For wall hung sink installation sensor conduit rough in should be directly under the basin to minimize sensor cord exposure Rough in drainage Rough in water supply to 10 control box inlets and to spout connection Finish walls STEP 2 FAUCET INSTALLATION Mount faucet to sink using nut s and washer s pro
7. O BAJO ESTA GARANT A DEBE SER HECHO DURANTE EL PER ODO DE CINCO A OS ARRIBA MENCIONADO CUALQUIER GARANT A IMPL CITA INCLUYENDO LA GARANT A INPL CITA DE COMERCIABILIDAD DE EMPLEO PARA UN PROP SITO PARTICULAR TIENE UNA DURACI N LIMITADA A LA DURACI N DE ESTA GARANT A LOS CARGOS DE LABOR Y O DA O INCURRIDO DURANTE LA INSTALACI N REPARACI N O REPUESTO COMO TAMBI N DA OS INCIDENTALES O RESULTANTES ESPECIALES INDIRECTOS O PUNITIVOS RELACIONADOS CON LO MENCIONADO SON EXCLUIDOS Y NO SER N PAGADOS POR DELTA FAUCET Algunos estados no permiten limitaciones de la duraci n de una garant a impl cita limitada o la exclusi n o limitaci n de da os incidentales o consecuentes de manera que las limitaciones o exclusiones arriba mencionadas puedan no aplicarle a usted Esta garant a le da derechos legales espec ficos y usted tambi n puede tener otros derechos que var an de estado a estado Esta garant a es solo para productos comerciales de Delta Faucet Company y Delta Faucet Canada una divisi n de Masco Canada Limitada y es nula por cualquier da o hecho a esta llave de agua resultante del mal uso abuso descuido accidente instalaci n incorrecta cualquier uso en violaci n de las instrucciones proporcionadas por Delta Faucet o cualquier uso de piezas de repuesto que no sean de piezas genuinas de Delta Delta Faucet Canada a division of Masco Canada Limited Delta Faucet Company Box 5750 420 Burbrook Place London ON Canada N6A
8. anty gives you specific legal rights and you may also have other rights which vary from state to state This warranty is for commercial products only from Delta Faucet Company and Delta Faucet Canada a division of Masco Canada Limited and is void for any damage to this faucet due to misuse abuse neglect accident improper installation any use in violation of instructions furnished by Delta Faucet or any use of replacement parts other than genuine Delta parts GARANTIE LIMITEE DELTA COMMERCIAL Toutes les pi ces des robinets de marque Delta HDF et TECK sont garanties contre tout d faut de mati re de finition et de main d oeuvre pour une p riode de cing 5 ans sauf indication contraire stipul e dans le catalogue et la liste des prix Cette garantie est offerte a l acheteur original et entre en vigueur a compter de la date d achat indiqu e sur la preuve d achat Delta proc dera a son enti re discr tion a la r paration ou au remplacement SANS FRAIS durant la p riode de garantie de toute pi ce qui pr sente un d faut de mati re ou de main d oeuvre dans des conditions d installation d usure d eau et de service normales Si Delta Faucet d termine que la pi ce retourn e a t fabriqu e par Delta Faucet et qu en effet cette pi ce fait d faut Delta Faucet respectera alors la garantie stipul e aux pr sentes Les pi ces de rechange peuvent tre obtenues chez votre marchand local ou le distributeur inscri
9. cates that both the sensor and the solenoid are functioning clicking sound Ensure inlet screen on solenoid is not plugged with debris Clean as required Check the incoming water supply Turned on proper pressure and Correct as required volume etc If no Check for a pressure lock between the mixing valve and the clicking sound solenoid Turn off the water supply and undo the connection to the inlet of the solenoid this will eliminate any built up pressure Then activate sensor and test fire the solenoid If after above there is no clicking sound Replace 060910A or Defective solenoid 060671A Solenoid If faucet does not activate or works Check for electrical interference erratically Check for interference from other electrical devices within close Call Technical Service if proximity to the spout or battery box Devices such as other infrared any such conditions devices transformers etc found 1 800 387 8277 CIJ If after completion of all above steps the valve still does not function correctly Call Technical Service for further assistance at 1 800 387 8277 Step 4 TECK Page 6 203910 Rev A Delta Commercial Faucet Limited Warranty All parts of the Delta HDF and TECK faucets are warranted to the original consumer purchaser to be free from defects in material finish and workmanship for a period of five 5 years unless otherwise specifically stated in the catalogue and price book This warranty is made to the original
10. consumer purchaser and shall be effective from date of purchase as shown on purchaser s receipt Delta will at its option repair or replace FREE OF CHARGE during the warranty period any part which proves defective in material or workmanship under normal installation use and water and service conditions If Delta Faucet concludes that the returned part was manufactured by Delta Faucet and is in fact defective then Delta Faucet will honour the warranty stated herein Replacement parts can be obtained from your local dealer or distributor listed in the telephone directory or by returning the part along with the purchaser s receipt to our factory TRANSPORTATION CHARGES PREPAID at the address listed THIS WARRANTY IS THE ONLY EXPRESS WARRANTY MADE BY DELTA ANY CLAIMS MADE UNDER THIS WARRANTY MUST BE MADE DURING THE FIVE YEAR PERIOD REFERRED TO ABOVE ANY IMPLIED WARRANTIES INCLUDING THE IMPLIED WARRANTY OF MERCHANTABILITY OF FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED IN DURATION TO THE DURATION OF THIS WARRANTY LABOUR CHARGES AND OR DAMAGE INCURRED IN INSTALLATION REPAIR OR REPLACEMENT AS WELL AS INCIDENTAL AND CONSEQUENTIAL SPECIAL INDIRECT OR PUNITIVE DAMAGES CONNECTED THEREWITH ARE EXCLUDED AND WILL NOT BE PAID BY DELTA FAUCET Some states do not allow limitations on how long an implied warranty lasts or the exclusion or limitation of incidental or consequential damages so the above limitations or exclusions may not apply to you This warr
11. housing cover as the electronic product is ready for use Selection Adjustment Sensor Range Auto Timer faucet shut off TECK You can set the distance at which the 9 from sensor sensor will detect hands in the wash area A safety mode in the event the sensor 45 seconds continually sees a target AUTO TIMER FAUCET SHUT OFF Operation Illustration Minimum Recommended le Distance 9 229mm Sensing Zone 9 228mm default Ls A 25mm DRIVER BOARD QUICK REFERENCE CHART Adjustment Range 3 to 15 from sensor 15 30 45 60 and 75 seconds Auto Timer is a safety mode in the event the sensor continually sees a target ie tape on the sensor In this case the faucet will stop after the pre determined time period expires The Auto Timer values are 15 30 45 60 and 75 seconds The Auto Timer default value is 45 seconds To adjust the Auto Timer feature press and release the yellow pushbutton on the left hand side of the digital light display The current Auto Timer setting will then appear on the light display Press and release the same pushbutton continuously to scan through the variable time periods which are displayed as seconds on the digital light display To return to operation mode do nothing for 5 seconds SENSOR RANGE 3 15 The sensor range is the maximum distance at which the user i
12. ic Mixing Valve to obtain the desired temperature counterclockwise to increase temperature clockwise to decrease temperature Fig 11 Periodic Inspection Maintenance This valve requires periodic inspection and verification of the outlet temperature by a licensed contractor Corrosive water conditions hot feed water temperatures over 200 F 93 C unauthorized adjustment or repair could render the valve ineffective for its intended service Regular cleaning and checking of thermostat assembly helps to maximize valve life and mixing function Frequency of cleaning depends on local water conditions 4D Close stop s STEP 5 CONNECT ELECTRICAL SUPPLY SOLENOID VALVE AND SENSOR Remove plastic threaded spacer nipple and install solenoid valve with body arrow in the direction of water flow See Fig 12 Feed sensor wire from spout into control box and then into the battery box Connect red solenoid cord to marked solenoid terminal on solenoid valve black solenoid cord to other solenoid terminal BATTERY VERSION Remove cover from control box and install four C batteries provided into the battery holder After the batteries are installed make the sensor connection on the driver board Connect battery clip to battery pack One beep should occur to indicate power is applied Two beeps indicate product is ready to use Use caution not to damage wires or components on electronic driver board Secure cover using screws HARDWIR
13. if d abus de n gligence d accident de mauvaise installation tout usage en contravention des directives fournies par Delta Faucet ou tout usage de pi ces de rechange autres que des pi ces originales Delta Garant a Limitada de las Llaves de Agua Comerciales Delta Todas las piezas de las llaves de agua grifos Delta HDF TECK est n garantizadas al comprador consumidor original de estar libres de defectos de material acabado y fabricaci n por un per odo de cinco 5 a os a menos que sea establecido espec ficamente de otra manera en el cat logo o libro de precios Esta garant a se le hace al comprador consumidor original y ser efectiva desde la fecha de compra como mostrado en el recibo del comprador Delta a su opci n reparar o reemplazar GRATUITAMENTE durante el per odo de garant a cualquier pieza que pruebe ser defectuosa en material o fabricaci n bajo instalaci n uso agua y condiciones de servicio normales Si Delta Faucet concluye que la pieza devuelta fue fabricada por Delta Faucet y es de hecho defectuosa entonces Delta Faucet honrar la garant a establecida en este documento Las piezas de repuesto se pueden obtener de su comerciante o distribuidor local listado en el libreto telef nico o devolviendo la pieza junto con el recibo del comprador a nuestra f brica CARGOS DE TRANSPORTE PRE PAGADOS a la direcci n incluida ESTA GARANT A ES LA NICA GARANT A EXPRESA HECHA POR DELTA CUALQUIER RECLAMO HECH
14. ot work properly follow the steps below in order Check to ensure faucet was installed Note See attached M amp l Pages 1 to 5 according to the M amp sheet Test for operation If unit does not Check lens to be sure it is not blocked with foreign matter Remove operate vinyl scratch protector from sensor if present Check to be sure power cable is properly secured in fitting Check to be sure batteries are fresh and properly installed Check two wires to solenoid to be sure they are connected correctly Check to be sure water supply is turned on If faucet shuts off due to interference When the faucet detects an object for longer than 45 seconds it will automatically shut off until the object is removed Once the object is removed for at least 1 second the faucet will operate normally Faucet makes beeping noise BATTERY POWERED Faucet beeps twice when turning off indicates Replace batteries batteries are low and need to be replaced 1500 Cycles or 2 weeks left Faucet beeps continuously when hands in front of spout and no Replace batteries water Faucet locked out because batteries are too low HARDWIRE Check voltage from converter and transformer It should Replace Hard Wire be approx 6 4 volts dc coming from converter to the driver board ama 060683A if required The faucet stops working No water The solenoid should click when activated flow Check the function of the solenoid If there is a This indi
15. s detected The sensor range includes 3 6 9 12 and 15 The sensor range default value is 9 Note Sensor ranges 1 subject to environmental conditions To adjust the sensor range value press and release the yellow pushbutton on the right hand side of the digital light display The current Sensor Range setting will then appear on the light display Press and release the same pushbutton continuously to scan through the variable sensor ranges which are displayed as inches on the digital light display To return to operation mode do nothing for 5 seconds If you have any questions about the installation of this product or need help trouble shooting this product please call Delta Commercial Technical Services at 1 800 387 8277 Page 5 203910 Rev A INSTALLATION AND SET UP INSTRUCTIONS FOR RECESS MOUNT HOUSING CONTROL BOXES 1 6 8 CARE INSTRUCTIONS This Delta Commercial faucet is designed and engineered in accordance with the highest quality and performance standards With proper care it will give years of trouble free service Care should be given to the cleaning of this product Although the chrome finish is extremely durable it can be DAMAGED by ACIDIC CLEANERS eg cleaners designed specifically for vitreous china lavatories and water closets HARSH ABRASIVE or POLISH To clean simply wipe the surface with a damp cloth and blot dry with a soft cloth TROUBLE SHOOTING GUIDE If the faucet does n
16. t dans votre annuaire t l phonique ou en retournant la pi ce ainsi que la preuve d achat a notre usine FRAIS DE TRANSPORT PREPAYES a l adresse indiqu e CETTE GARANTIE EST LA SEULE GARANTIE EXPRESSE FAITE PAR DELTA TOUTE RECLAMATION FAITE EN VERTU DE CETTE GARANTIE DOIT ETRE PRESENTEE DURANT LA PERIODE DE CINQ ANS MENTIONNEE CI DESSUS TOUTE GARANTIE IMPLICITE Y COMPRIS LA GARANTIE IMPLICITE DE VALEUR COMMERCIALE RELATIVEMENT A L APTITUDE A LA FONCTION EST LIMIT E EN TERMES DE DUR E POUR LA DUR E DE CETTE GARANTIE LES FRAIS DE MAIN D OEUVRE ET OU DE DOMMAGES ENCOURUS DURANT L INSTALLATION LA R PARATION OU LE REMPLACEMENT AINSI QUE LES DOMMAGES INTERETS ACCESSOIRES OU IMMATERIELS SPECIAUX INDIRECTS OU PUNITIFS S Y RAPPORTANT SONT EXCLUS ET NE SERONT PAS PAYES PAR DELTA FAUCET Certains tats ne permettent pas la limitation de la dur e de la garantie implicite ou l exclusion ou la limitation des dommages int r ts accessoires ou immat riels et par cons quent les limitations ou les exclusions stipul es ci dessus peuvent ne pas s appliquer dans votre cas Cette garantie vous accorde certains droits reconnus par la loi et vous avez peut tre aussi d autres droits qui varient d un tat a l autre Cette garantie s applique seulement aux produits commerciaux des soci t s Delta Faucet et Delta Faucet Canada une filiale de Masco Canada Limited et est nulle de plein droit pour tout dommage caus a ce robinet en raison d usage excess
17. th Check 060073A Screws 4 pkg and driver bit for covers Page 3 203910 Rev A INSTALLATION AND SET UP INSTRUCTIONS FOR RECESS MOUNT HOUSING CONTROL BOXES 1 6 8 STEP 3 CONNECT WATER SUPPLY Install sink and connect drainage to rough in See applicable Fig 7 Fig 8 or Fig 9 Please note that the connection tube and fittings are supplied by the installer to connect the 3 8 MIP at the box outlet and compression joint for 3 8 O D Soft copper tube at the spout Connect water supply through to spout Assure supply lines are completely flushed and free of debris STEP 4 FLUSH SYSTEM SET TEMPERATURE 1 Remove coverplate from control box Open screwdriver Watertight stop s to flush installation for 1 minute minimum Connector o SUPPLIED 4A Run water for a sufficient time so the hot and cold 3 8 MIP Outlet from Box water supplies are as hot and cold as they will get Eras 3 8 Compression Joint at Spout BALANCE BY OTHER 4B Place a thermometer in a plastic container and hold Cord Conduit id S in the water stream Record the temperature reading and note position of temperature control and lock at desired setting 4C if Mechanical Mixing Valve 060911A Fig 8 Adjust setting to the desired temperature and lock 305mm 12 in place by tightening the vandal resistant screw Stainless Steel Control Box Cover Plate If Thermostatic Mixing Valve Fig 9 Adjust setting of the Thermostat
18. vided Fig 1 NOTE Use clear silicone sealant between faucet and lavatory to prevent water from leaking beneath lavatory Control Box 1 Flexible Sensor Cord Conduit Supplied on Recessed Mount Box 3 8 MLE A o Control Box Control Box 8 Flexible Sensor N Y Flexible Sensor d any Coles d uo moon upplied on batte upplied on ira recessed mount box holder not recessed mount box required required for Inlets 1 2 for Inlets 1 2 hardwire Copper Copper Outlet models 3 8 M P models 060671A O 3 4 NPS 060907A Solenoid Driver Valve board to be located on this bracket o 060576A Screwdriver o Stop o o Tempered Water By Others o QU Inlet 1 2 Copper Fig 7 COVERS 060577A 12 Stainless Steel Cover TECK 7 Driver board 060907A to be located Driver board on this bracket to be located E on this E bracket e o D an 060911A 0 Mechanical 60912A 060829A Mixing Valve 0608294 ermostatic Mixing Valve O Fig 8 Screwdriver Stops wi
19. your system never exceeds its maximum intended pressure setting OPTION LIST aT 060681A 060910A Solenoid Valve with 3 8 Compression Connectors 060908A Solenoid Holder 060909A Screen Assembly Battery Holder 060571A Mounting Hardware TRANSFORMERS 060704A Transformer 110 to24 VAC 20VA up to 5 Electronic Valves 060771A Transformer 110 to24 VAC 40VA up to 10 Electronic Valves 060772A Transformer 110 to24 VAC 100VA up to 25 Electronic Valves PLEASE LEAVE this M Sheet with the owner maintenance plumber etc as items relating to ongoing maintenance suggestions and procedures are included TECK Page 1 203910 Rev A Installation should be in accordance with local plumbing and electrical codes FLUSH ALL PIPES THOROUGHLY BEFORE INSTALLATION INSTALLATION AND SET UP INSTRUCTIONS FOR SURFACE MOUNT HOUSING CONTROL BOX 0 STEP 1 FAUCET INSTALLATION Connect 20 braided hose to spout inlet Mount faucet to sink using nut s and washer s provided Fig 1 NOTE Use clear silicone sealant between faucet and lavatory to prevent water from leaking beneath lavatory STEP 2 BATTERY BOX INSTALLATION Mount battery box to wall under sink using the 4 supplied screws and anchors Use 1 4 drill for wall anchors Be sure to install the box within the dimensions provided so the hose and spout cable will reach connections at faucet and battery box Refer to illustration

Download Pdf Manuals

image

Related Search

Related Contents

取扱説明書  Canon 9156B001 Digital Camera User Manual  Installationsanleitung-Junkers-CeraStar-ZWN-24-7-AE    BI10-03 Préconisations pour l`installation de l`Altherma HT  Serial Communication Module User`s Manual (Hardware)  Manuel d`installation  Systèmes Dell PowerVault Network Attached Storage (NAS) Guide    Express VB - Vermeiren  