Home

Tripp Lite B004-VPA2-K-R User's Manual

image

Contents

1. loss of equipment loss of use of equipment loss of software loss of data costs of substitutes claims by third parties or otherwise Warranty Registration Visit www tripplite com warranty today to register the warranty for your new Tripp Lite product You ll be automatically entered into a drawing for a chance to win a FREE Tripp Lite product No purchase necessary Void where prohibited Some restrictions apply See website for details Use of this equipment in life support applications where failure of this equipment can reasonably be expected to cause the failure of the life support equipment or to significantly affect its safety or effectiveness is not recommended Do not use this equipment in the presence of a flammable anesthetic mixture with air oxygen or nitrous oxide The policy of Tripp Lite is one of continuous improvement Specifications are subject to change without notice Copyright 2007 All rights reserved All trademarks are the property of their respective owners 200710180 93 2713
2. Step 4 Power up the connected computers After your computers are powered up the keyboard and mouse will automatically be recognized The KVM Switch should now be powered up You can now begin operating the KVM Switch Push Button Switching The built in push buttons allow you to directly control switching between computers Simply press the button to switch computer ports By default Audio Mic and PC Switching are simultaneous To disable this feature use the hot key sequence ScrLk ScrLk W See Quick Reference Guide Keyboard Hot Key Switching A keyboard hot key sequence consists of at least three specific keystrokes See Quick Reference Guide Hot key sequence ScrLk ScrLk command key s User definable Scroll Lock Caps Esc F12 or Num Lock Hot Key Sequence Configuration For users who want to use a sequence other than the two consecutive Scroll Locks the BO04 VPA2 K R offers an additional convenient sequence configuration option Step 1 Hit Scroll Lock H two beeps will signal readiness for new sequence selection Or press and hold down the last push button Port Selection Button until you hear two beeps and then release the button Step 2 Select and press the key you would like to use as your sequence Scroll Lock Caps Esc F12 or Num Lock keys are available for selection and you
3. ll hear a beep for selection confirmation Now you can use the new sequence to execute your hot key commands Each keystroke within a hot key sequence should be pressed within 2 seconds Otherwise the hot key sequence will not be valid For detailed hot key sequences and their corresponding functional commands please refer to the Quick Reference Guide on the other side of this manual Quick Reference Guide 2 Port Compact PS 2 KVM Switch Operation Commands for Hot Keys Push Buttons Hot key sequences ScrLk ScrLk Command key s User definable preceding sequence Scroll Lock Caps Esc F12 or Num Lock Command Hot Keys Push Buttons Description Select PC Channel Select PC port and Audio Mic port if simultaneous operation is enabled SerLk ScrLk x Selects PC channel Select Audio Mic Channel ScrLk ScrLk Fx Selects Audio Mic channel Enable Simultaneous PC and Audio Mic Switching ScrLk ScrLk Q Enables simultaneous operation of PC and Audio Mic Switching Disable Simultaneous PC and Audio Mic Switching SerLk SerLk W Disables simultaneous operation of PC and Audio Mic Switching Choosing Next PC Channel ScrLk ScrLk arrow up Select PC port and Audio or Mic port if simultaneous ScrLk SerLk V arrow down operation is enabled Press the push button to switch to the next PC channel Selects next PC channel Choosing the Pr
4. 2 Port Compact PS 2 KVM Switch with Audio Model BO04 VPA2 K R Tested To c FOR TRIPP LITE 1111 W 35th Street Chicago IL 60609 USA 773 869 1234 www tripplite com The B004 VPA2 K R is a 2 port compact PS 2 KVM Switch with optional audio and microphone switching function It allows you to access control boot and reboot multiple PS 2 enabled computers using a single keyboard monitor mouse console and optional speaker set and microphone The B004 VPA2 K R also offers user programmable simultaneous independent switching of applications For users who need to use a hot key sequence other than the pre programmed scroll locks it also offers five hot key configuration alternatives Installation The KVM Switch is a plug and play device eliminating the need to configure the KVM Switch before installation Note Before connecting the KVM Switch to the computers make sure all connected computers are powered off Otherwise the computers will not be able to recognize the connected keyboard and mouse Step 1 Make sure all computers that are to be connected to the KVM Switch and their peripherals are in a powered off state If not power them off before you proceed with the following steps Step 2 Connect the shared PS 2 keyboard mouse monitor speaker set and microphone to the KVM Switch Step 3 Connect each of your computers to the KVM Switch using the included KVM and audio microphone cables
5. evious PC Channel SerLk ScrLk Backspace Selects the previous PC channel Define Hot Key 4 Sequence SerLk ScrLk H y Press and hold down the last push button Port Selection Button until you hear two beeps release the button and then press the y key Sets the hot key sequence using 1 of 5 alternative keys Console 6 Mouse Keyboard Reset SerLk SerLk End Resets keyboard and mouse on the console side Autoscan ScrLk SerLk S Autoscans through every connected channel for quick screen browsing of each channel scan delay 5 sec ScrLk ScrLk S x x 0 9 iSi 2S Aor GS ssi Sao Si 50 6 60 770 C50 9 gt 907 0 gt 100 Autoscan with Programmable Delay Time Autoscans with a user defined delay time within a range of 5 100 seconds Stop Autoscan Press any key on keyboard Press any button Terminates Autoscan activity Notes k By default PC and Audio Mic switching are simultaneous Fx denotes a function key F1 or F2 at the top of the keyboard Hot key convention The hot key notation SerLk ScrLk key denotes that you should hit the individual key consecutively one at a time not simultaneously Note that x denotes a number key for the selected port x 1 2 2 3 4 y denotes your choice of hot key command Choose from ScrLk CapsLock Esc F12 or NumLock 5 6 Mouse Troubleshooting If your mouse locks up or behaves ab
6. ited Warranty TRIPP LITE warrants its products to be free from defects in materials and workmanship for a period of one 1 year from the date of initial purchase TRIPP LITE s obligation under this warranty is limited to repairing or replacing at its sole option any such defective products To obtain service under this warranty you must obtain a Returned Material Authorization RMA number from TRIPP LITE or an authorized TRIPP LITE service center Products must be returned to TRIPP LITE or an authorized TRIPP LITE service center with transportation charges prepaid and must be accompanied by a brief description of the problem encountered and proof of date and place of purchase This warranty does not apply to equipment which has been damaged by accident negligence or misapplication or has been altered or modified in any way EXCEPT AS PROVIDED HEREIN TRIPP LITE MAKES NO WARRANTIES EXPRESS OR IMPLIED INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE Some states do not permit limitation or exclusion of implied warranties therefore the aforesaid limitation s or exclusion s may not apply to the purchaser EXCEPT AS PROVIDED ABOVE IN NO EVENT WILL TRIPP LITE BE LIABLE FOR DIRECT INDIRECT SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE OF THIS PRODUCT EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE Specifically TRIPP LITE is not liable for any costs such as lost profits or revenue
7. normally you can hit the following hot key commands to reset the mouse A When using a PnP OS such as Windows 98 Second Edition Wink2k Win XP etc hit SerLk ScrLk End for mouse reset B When using a non PnP OS such as Linux NT4 0 etc hit one of the following hot key commands for mouse reset according to your mouse configuration on the non PnP OS SerLk SerLk M 1 for a 2 key mouse setting SerLk ScrLk M 2 for a 3 key wheel mouse setting SerLk ScrLk M 3 for a 5 key wheel mouse setting FCC Radio TV Interference Notice Note This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense The user must use shielded cables and connectors with this product Any changes or modifications to this product not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment 1 Year Lim

Download Pdf Manuals

image

Related Search

Related Contents

参考資料1 第2回建築材料断熱性能表示制度ワーキング  製品安全データシート (ワンパルス271)  EN User manual DE Benutzerhandbuch FR  Manual - Tramontina  Do`s and Don`ts of Care and Maintenance 1-877-877  30” Freestanding Gas Range SERVICE MANUAL  SIS Student Information System - Hebrew Union College  Mode d`emploi de la salle JERSEY  Romoss eUSB Ranger 95 Data sheet PDF (english version)  StabiliSation tartrique par gomme de cellulose (cmc) : mode d`emploi  

Copyright © All rights reserved.